by STULZ Air Technology Systems, Inc. Protherm Outdoor Air Conditioners COSMOTEC MISSION... is to be the premier provider of energy efficient thermal management products for industrial applications. 2015 800-465-9241 Information / Drawings subject to change without notice
Air Conditioners Protherm Design Features 380 Watts 6000 Watts Micro Channel Condensing Coil (Model 11 and larger) - Full Aluminum Design - Corrosion Protection (Standard on CVO Models) - Filterless Design - Eliminates Coil Oxidation Low Ambient Packages (Standard on CVO Models) Passive Condensate Management Simplified Mounting Design Optional Heater Packages (1kW / 3kW) Digital Controller All Models except CVE03 Sequencing (Lead/Lag) Modbus Alarm Functions Remote Door Switch Capable Remote Display (Standard on CVO Models) Short Cycle Protection Industry Standards UL Listed (File # SA12046) Indoor: NEMA 12 Outdoor: NEMA 3R, 4 and 4X (optional) Industries Served Industrial & Process Automation Packaging and Logistical Systems Energy (Solar, Wind, Water and Petrochemical) Telecommunications Water / Wastewater Systems Defense Systems Product Attributes 7 Sizes of Air Conditioners; Capacity Range from 1,300 BTU to 20K BTU Voltage Options: 48VDC, 115VAC, 230VAC and 460VAC 3Phase Operating s: - Indoor: 20 C/68 F to 55 C/131 F - Outdoor: -40 C/-40 F to 55 C/131 F All Models Powder Coated RAL7035 R134a Earth Friendly Refrigerants Used All Units Functionally Tested Before Shipment 4 Information / Drawings subject to change without notice 800-465-9241 5
Air Conditioners - Protherm Options: Air Filter Special Color Display for Protherm Models (standard on all models except Model 03) Stainless steel housing 304/ Sequencing cable (ACASEQ) Epoxy or cataphoresis treatment condenser coil (standard on outdoor models) Serial port for Modbus (ACASPM) Electrical heater 1kW (CVO11 & larger) 3kW (CVO40) Smart Energy 2 Management probe (ACARES) SAVING ENERGY Micro Channel Condenser Coils: The big benefit of a smaller package It has been said that great things come in small packages, and Cosmotec s Microchannel Condenser Coils are no exception. Cosmotec has developed a condenser technology for air conditioners that allows us to save space, use less refrigerant, reduce weight, minimize coil oxidation and increase performance all at the same time. By adapting philosophies from the Automotive Industry we have developed our new Micro Channel Condensing Coil to improve the performance of our air conditioners. Smaller Footprint (40% of Original Design) Lighter Weight Reduction of Refrigerant volume Reduced Maintenance Elimination of Coil Oxidation Improved Performance Parallel Flow Tubes Header MicroChannel Design Enhanced Aluminum Fins 6 800-465-9241 Information / Drawings subject to change without notice 5
Outdoor Air Conditioners - Protherm CVO05 Specification CVO05U12038000 CVO05U12208000 CVO05U1203800I CVO05U1220800I CVO05U12128000 CVO05U1212800I Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60 48VDC 48VDC L35L35 - W(BTU) 580 (1,979) 580 (1,979) 500 (1,706) L35L50 - W(BTU) 430 (1,467) 430 (1,467) 350 (1,194) Stainless Steel - 304 N/A N/A Optional Heater N/A Dimensions - mm 634.5 x 313 x 235.5 Dimensions - in 25 x 12.3 x 9.3 Max Running Current / Starting Current - A 4 / 30 1.5 / 15 4 / 30 1.5 / 15 6.1 / - Power Consumption L35L50 - W 340 340 300 Air Flow (free blowing) - m3/h(cfm) 195 (115) 195 (115) 450 (265) Regulation Limits - F 77 to 113 Ambient Limits - F -40 to 131 Protection Level Type 4 Type 4X Type 4 Type 4X Noise Level - db(a) 61 61 67 Weight - kg (lbs) 23 (51) CVO08 Specification CVO08U12038000 CVO08U12208000 CVO08U1203800I CVO08U1220800I Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60 L35L35 - W (BTU) 900 (3,070) 900 (3,070) L35L50 - W (BTU) 700 (2,388) 700 (2,388) Stainless Steel - 304 N/A Optional Heater N/A Dimensions - mm 634.5 x 313 x 235.5 Dimensions - in 25 x 12.3 x 9.3 Max Running Current / Starting Current - A 5.2 / 34 4 / 20 5.2 / 34 4 / 20 Power Consumption L35L50 - W 600 600 Air Flow (free blowing) - m3/h (CFM) 390 (230) 390 (230) Regulation Limits - F 77 to 113 Ambient Limits - F -40 to 131 Protection Level Type 4 Type 4X Noise Level - db(a) 65 Weight - kg (lbs) 27 (60) CVO11 Specification CVO11U12038000 CVO11U12208000 CVO11U1203800I CVO11U1220800I Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60 L35L35 - W (BTU) 1,150 (3,923) 1,150 (3,923) L35L50 - W (BTU) 890 (3,036) 890 (3,036) Stainless Steel - 304 N/A Optional Heater 1kW 1kW Dimensions - mm 906 x 410 x 272 Dimensions - in 35.7 x 16.1 x 10.7 Max Running Current / Starting Current - A 6.4 / 34 2.8 / 16 6.4 / 34 2.8 / 16 Power Consumption L35L50 - W 650 650 Air Flow (free blowing) - m3/h(cfm) 580 (341) 580 (341) Regulation Limits - F 77 to 113 Ambient Limits - F -40 to 131 Protection Level Type 4 Type 4X Noise Level - db(a) 65 Weight - kg (lbs) 44 (97) All CVO units are 10 800-465-9241 Information / Drawings subject to change without notice 9
Outdoor Air Conditioners - Protherm CVO15 Specification CVO15U12038000 CVO15U12208000 CVO15U12628000 CVO15U1203800I CVO15U1220800I CVO15U1262800I Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 400/460-3-50/60 115-1-60 230-1-50/60 400/460-3-50/60 L35L35 - W (BTU) 1,600 (5,459) 1,500 (5,118) 1,600 (5,459) 1,500 (5,118) L35L50 - W (BTU) 1,280 (4,367) 1,200 (4,094) 1,280 (4,367) 1,200 (4,094) Stainless Steel - 304 N/A N/A Optional Heater 1 kw N/A 1 kw N/A Dimensions - mm 906 x 410 x 272 996 x 409 x 286 906 x 410 x 272 996 x 409 x 286 Dimensions - in 35.7 x 16.1 x 10.7 39.2 x 16.1 x 11.3 35.7 x 16.1 x 10.7 35.7 x 16.1 x 11.3 Max Running Current / Starting Current - A 9.5 / 32 4.2 / 17 2.5 / 16 9.5 / 32 4.2 / 17 2.5 / 16 Power Consumption L35L50 - W 825 890 825 890 Air Flow (free blowing) - m3/h (CFM) 580 / 341 580 / 341 Regulation Limits - F 77 to 113 Ambient Limits - F -40 to 131 Protection Level Type 4 Type 4X Noise Level - db(a) 65 65 Weight - kg (lbs) 46 (101) 48 (106) 46 (101) 48 (106) CVO20 Specification CVO20U12038000 CVO20U12208000 CVO20U12628000 CVO20U1203800I CVO20U1220800I CVO20U1262800I Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 400/460-3-50/60 115-1-60 230-1-50/60 400/460-3-50/60 L35L35 - W (BTU) 2,200 (7,506) 2,100 (7,165) 2,200 (7,506) 2,100 (7,165) L35L50 - W (BTU) 1,850 (6,312) 1,800 (6,141) 1,850 (6,312) 1,800 (6,141) Stainless Steel - 304 N/A N/A N/A Optional Heater 1kW N/A 1kW N/A Dimensions - mm 996 x 409 x 286 Dimensions - in 39.2 x 16.1 x 11.3 Max Running Current / Starting Current - A 11.5 / 65 7.3 / 34 2.6 / 18 11.5 / 65 7.3 / 34 2.6 / 18 Power Consumption L35L50 - W 1240 Air Flow (free blowing) - m3/h(cfm) 930 (5) Regulation Limits - F 77 to 113 Ambient Limits - F -40 to 131 Protection Level Type 4 Type 4X Noise Level - db(a) 68 Weight - kg (lbs) 48 (106) CVO40 CV060 Specification CVO40U12208000 CVO40U12628000 CVO40U1220800I CVO40U1262800I CV06U12628000 CV06U1262800I Power Supply - V-Ph-Hz 230-1-50/60 400/460-3-50/60 230-1-50/60 400/460-3-50/60 460-3-60 L35L35 - W (BTU) 4,100 (13,989) 4,050 (13,819) 4,100 (13,989) 4,050 (13,819) 5,950 (20,300) L35L50 - W (BTU) 3,300 (11,260) 3,260 (11,123) 3,300 (11,260) 3,260 (11,123) 4,850 (16,550) Stainless Steel - 304 N/A N/A N/A Optional Heater 1kW or 3kW N/A 1kW or 3kW N/A N/A Dimensions - mm 1211 x 511 x 356 1400 x 555 x 416 Dimensions - in.7 x 20.1 x 14 55 x 22 x 16 Max Running Current / Starting Current - A 10.5 / 46.5 3.5 / 18 10.5 / 46.5 3.5 / 18 8.11 Power Consumption L35L50 - W 1950 3,600 Air Flow (free blowing) - m3/h (CFM) 1300 (765) 1,600 (942) Regulation Limits - F 77 to 113 77 to 113 Ambient Limits - F -40 to 131-40 to 131 Protection Level Type 4 Type 4X Type 4 Type 4X Noise Level - db(a) 70 71 Weight - kg (lbs) 86 (189) 100 (220) All CVO units are 10 Information / Drawings subject to change without notice 800-465-9241 11
Outdoor Air Conditioners - Protherm CVO05 CVO08 314 235.6 31.5 313.5 35.8 242 35.8 16.5 314 235.6 31.5 313.5 35.8 242 35.8 142 162.5 634.5 16.5 642 132 463 634.5 463 16.8 280 16.8 142 162.5 642 132 16.8 280 16.8 20.5 26.8 260 26.8 20.5 26.8 260 26.8 CVO11 CVO15* 410 272 84.5 410 19.5 371 19.5 24.5 410 272 84.5 410 19.5 371 19.5 240 906 913 690 164 24.5 108.5 35 340 35 198.5 108.5 409 286 84.5 410 19.5 371 19.5 24.5 511 512 356 46 420 46 996 1005 1211 690 400 940 164 240 906 913 690 164 35 340 35 198.5 *The dimensions for the CVO15U12628000(I) are the same as the CVO20 dimensions CVO20 CVO40 179 24.5 24.5 Measurements shown in mm (refer to pages 10-11 for in.) 1400 CVO60 555 416 91.5 431 340 340 179 24.5 200.5 240 35 340 35 290.5 556 462 59 438 59 42 2 42 1000 25.5 380.5 530 85.5 61 390 61 41 430 41 254.5 12 800-465-9241 Information / Drawings subject to change without notice 11
Outdoor Air Conditioners - Protherm CVO05 CVO08 850 800 750 700 650 600 550 500 450 400 350 300 250 Ambient 1300 1200 1100 1000 900 800 700 600 500 400 Ambient CVO11 CVO15* 1750 1600 1450 1300 1150 1000 850 700 550 Ambient 2400 2250 2100 1950 1800 1650 1500 1350 1200 1050 900 Ambient CVO20 CVO40 3000 2800 2600 2400 2200 2000 1800 1600 1400 Ambient Performance (230V) 5500 5200 4900 4600 4300 4000 3700 3400 3100 2800 2500 2200 CVO60 Performance (460VAC) 8000 7500 7000 6500 6000 5500 5000 4500 4000 3500 Ambient 12 Information / Drawings subject to change without notice 800-465-9241
STULZ Global Presence Germany U.S.A. Italy China India Production Facilities: U.S.A. Germany Italy China India On-Site Product Support: Worldwide globally close to you by STULZ Air Technology Systems, Inc. Registered ISO9001 Quality System ISO-9001 Quality Registered Cosmotec Industrial Cooling, a part of STULZ Air Technology Systems, Inc. 1572 Tilco Drive, Frederick, Maryland 21704 Phone: 800-465-9241 Service: 888-529-1266 E-mail: info@stulz-cosmotec.com thermal.stulz-cosmotec.com (Thermal Calculation Tool) October 2015 Technical data subject to change without notice. Information / Drawings subject to change without notice 800-465-9241