Controlled Environment Equipment Solutions for the Lab

Similar documents
Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

NU-430/435 CLASS II, TYPE B2 BIOLOGICAL SAFETY CABINETS

Best Products. Best Performance. Best Protection.

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific

LABGARD FEATURES

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

General. Technical Bulletin: ACCESSORY INFORMATION

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

LAMINAR AIRFLOW EQUIPMENT

convenience. containment. comfort. Thermo Scientific Class II, Type A2 Biological Safety Cabinets

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

BSC-1100IIA2-X is designed to meet the operating principles:

SterilGARD. Meets NSF Standards. Underwriter Laboratories Listed

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CLASS II BIOSAFETY CABINET

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Biological Safety Cabinet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

As ept i c I s olator s

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

(Class II Type A2 & B2)

Appendix C: Biosafety Cabinet Specifications C-1. Product Service

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

3 Liter Programmable Centrifuges

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

SterilGARD III Advance Sets the Industry s Highest Standard for Comfort, Performance and Safety.

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

THE SAFER CHOICE FOR YOUR LABORATORY.

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

(Class II Type A2 & B2)

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

Antech Group Inc. Tel/Fax: Web: SOLUTIONS

PCR Laminar Flow Cabinets

DESIGNED BY YOU. DESIGNED FOR YOUR APPLICATION.

Series EuroFlow Biological Safety Cabinets Class II

Protector Glove Boxes.

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

AS , EN12469 (Microbiological Testing Method)

Class II biological safety cabinets

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC.

Uncompromised safety. NSF listing provides assurance that you, your work and your laboratory environment are protected while working with agents that

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Biological Safety Cabinet. Feature & HEPA-filter efficiency

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Envirco BIOLOGICAL SAFETY CABINET

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SafeFAST Premium. Class II Microbiological Safety Cabinets THE LOWEST POWER CONSUMPTION THE LOWEST CO 2 EMISSIONS THE LOWEST NOISE LEVEL

VERSAFLOW SERIES UNIDIRECTIONAL LAMINAR AIRFLOW COMPOUNDING ASEPTIC ISOLATOR (CAI)

Requires Ductwork and Blower

Revolutionizing Clean Environments Containment. Comfort. Convenience

Class II, Biological Safety Cabinets Probably the Most Advanced Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

Refrigerators/Freezers

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Open Access Stations Introduction

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

Class II, Type A2 and B2 Biological Safety Cabinets The Most Certified Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

PROTECTOR FIBERGLASS ENCLOSURES

Airstream. Class II Type A2 Biological Safety Cabinets The World s Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

High Performance Ductless Balance Enclosures

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

BioChemGARD. Meets NSF Standards. Underwriter Laboratories Listed

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

Airstream. Class II Type A2 Bioltogical Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

Airstream Airstream. Class II Type A2 Biological Safety Cabinets The World s Leading Energy-Efficient, Quiet, and Ergonomic Biosafety Cabinet

Protector Demonstration Hoods

CLASS II BIOLOGICAL SAFETY CABINET

13. Life Sciences, Biotechnology Gel documentation-laminar flows/personal Protection

biolus BIO SAFETY CABINET

Laminar Flow Clean Benches, Horizontal and Vertical

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

Ductless Nanoparticle Containment Enclosures

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Transcription:

Controlled Environment Equipment Solutions for the Lab Forma Class II Biological Safety Cabinets Forma Laminar Airflow Workstations Analyze Detect Measure Control

Features and Technical Specifications Forma Class II Biosafety Cabinets and Laminar Airflow Workstations The Forma Advantage: Protection, Performance, Convenience... You re always seeking an advantage the protection of a safe environment in which to handle moderate to high risk microorganisms (biosafety level 1, 2, or 3 agents) for cell culturing, sample analysis, diagnostic procedures, or preparation of therapeutic agents; high quality equipment that will withstand the rigors of lab use and perform reliably day after day; comfort and convenience that make your work life easier and more productive. Thermo Electron Corporation provides the advantage. The Forma Advantage. For decades, researchers worldwide have trusted and valued controlled environment laboratory equipment that bears the Forma product name: the number one selling cell culture incubator in the world, high performance -86C freezers, and a comprehensive solution for your biosafety and laminar airflow cabinet needs. Forma Class II Biological Safety Cabinets and Laminar Airflow Workstations are trusted worldwide for their solid construction and dependability while providing maximum protection at an affordable price. Carefully directed, laminar airflow is key to optimum cabinet performance. Biosafety cabinet certifiers have noticed the consistency of our cabinets airflow. That stable, balanced airflow is the result of reliable design and quality construction that produce a precisely controlled Class 100 or better environment. Our laminar airflow workstations (clean benches) are designed to prevent backwashing. Contaminated outside air will not drift back into the workstation s work area, ensuring product protection. 2 Added convenience of standard features and a variety of accessories allow you to simplify daily use and routine procedures. Large sash openings on biosafety cabinets increase your mobility and depth of reach into the work area. Under-cabinet drawers help you organize your work area by providing local storage for pipettes, gloves, etc. BREADTH OF PRODUCTS 3 Year Warranty You can trust our biosafety and laminar airflow cabinets to provide the reliable protection you depend on everyday. Class II, A1 Biosafety Cabinets..4 Class II, A2 Biosafety Cabinets..8 Class II, B2 Biosafety Cabinets..10 Laminar Airflow Benchtops....14 Laminar Airflow Consoles......16

...for Peace of Mind and a Workstation Tailored to Your Needs Optional Exhaust Transition with Zero Leak Damper Front Access HEPA Filters Optional Universal Piping Minihelic Pressure Gauge Sidewall Mounted Outlet and Service Valve(s) Frameless Sash Optional ADA Control Panel Optional Armrest Exclusive Vortex Channels Rounded Front Optional Adjustable Modular Stand Optional Storage Drawers Optional Adjustable Footrest 3 Optional Lab Chair VARIETY OF ACCESSORIES Thermo helps you create an organized, complete biosafety cabinet or laminar airflow workstation tailored to your work requirements and comfort needs (Class II, A2 Biosafety Cabinet shown). Accessories for Biological Safety Cabinets.................12 Accessories for Laminar Airflow Workstations.............18

Features and Technical Specifications Forma Class II, A1 Biological Safety Cabinets A1 Consoles: A Practical Choice The Class II, A1 console cabinet is a practical choice when a clean air environment and product, personnel, and environment protection are required for working with agents assigned to biosafety levels 1, 2, or 3 in the absence of volatile toxic chemicals and volatile radionuclides. Large 10" (25.4cm) sash opening enhances your mobility and depth of reach into the work area, while still providing maximum protection. UV interlock provides additional safety by prohibiting UV light operation unless the sash is fully closed. Carefully Directed Airflow Airflow descends from the top of the cabinet through a supply HEPA filter. As this vertical airstream approaches the work surface, the airflow splits. Approximately 50% is drawn into the cabinet s rear intake grille, and the rest meets ambient room air at the front intake grille. The air is drawn into a negative pressure plenum under the work area by the blower located in the cabinet s base. The blower pushes the air into a positive pressure plenum and forces it to the top of the cabinet. The pressurized air is split, with 30% vented through the exhaust HEPA filter and 70% recirculated through the supply HEPA filter. 4 Reliable Protection, Convenient Setup and Use Low overall height permits easy passage through doorways and accommodates sites with limited ceiling height. For additional product and personnel protection, unique, patented Vortex Channels create high velocity air at the window corners to move turbulent air into the return air system, reducing the risk of particulates escaping from or entering the cabinet work area. AIRFLOW Inflow velocity 75 FPM minimum 70% recirculated within the cabinet 30% exhausted Ambient Air HEPA Filter Contaminated Air (positive pressure) Contaminated Air (negative pressure) HEPA Filtered Air U.S. Patents held include 5,295,902 and 5,380,244.

A1 Console Specifications Models 4 Ft. Console........ 1200 (1201) 6 Ft. Console........ 1214 (1205) Work Area Width - 1200 (1201)... 46.5" (118.1cm) Width - 1214 (1205)... 70.5" (179.1cm) Height............. 25.3" (64.3cm) F-B................ 25.0" (63.5cm) Sash Opening........ 10.0" (25.4cm) Exterior Dimensions Width - 1200 (1201)... 51.5" (130.8cm) Width - 1214 (1205)... 75.5" (191.8cm) Height............. 79.1" (200.9cm), height is with levelers in minimum position, add 3.0" (7.6cm) for exhaust grille F-B................ 34.7" (88.1cm), deduct 3.7" (9.4cm) for light canopy Electrical, Plug, Breaker, & Motor 1200............... 115V, 60 Hz, 13.6 FLA 1214............... 115V, 60 Hz, 14.7 FLA 1201............... 230V, 50 Hz, 9.6 FLA 1205............... 230V, 50 Hz, 10.0 FLA 115V............... NEMA 5-20P Plug 230V............... CEE 7/7 Plug Breaker Requirement.. 1200/1214: 20 Amp 1201/1205: 15 Amp Motor.............. 3/4 HP Exhaust Requirements 1200 (1201)......... 242-274 CFM* 1214 (1205)......... 391-440 CFM* Canopy Exhaust (opt.).. Add 30% to exhaust CFM Connection........ 8.0" (20.3cm) diameter duct connection, 0.25" w.g. psi drop at the connection Service Valves 1200 (1201)......... 1, right side 1214 (1205)......... 2, 1 on each sidewall Additional Plugged Penetrations 1200 (1201)......... 3, 1 on right and 2 on left sidewall 1214 (1205)......... 2, 1 on each sidewall Outlets 120V............... 2 GFIC protected duplex, 1 on each sidewall 230V............... 2, 1 on each sidewall Unit Heat Load 1200 (1201)......... 3150 BTUH (920 Watts) 1214............... 3050 BTUH (890 Watts) 1205............... 3600 BTUH (1,060 Watts) Weight Net 1200 (1201)........ 604 lbs. (274.0 kg) 1214 (1205)........ 770 lbs. (349.3 kg) Shipping (Motor) 1200 (1201)........ 730 lbs. (331.1 kg) 1214 (1205)........ 945 lbs. (428.6 kg) All units are UL Listed to United States and Canadian requirements and NSF Listed. *Cubic Feet per Minute (CFM) is based on the Direct Airflow Method, under clean conditions. 5

Features and Technical Specifications Forma Class II, A1 Biological Safety Cabinets A1 Benchtop: Ideal When Lab Space is Limited The Class II, A1 benchtop cabinet s small footprint provides 2.9 sq. ft. (0.3 sq. m) of work area while requiring only 5.4 sq. ft. (0.5 sq. m) of valuable lab space. Dependable Protection, Easy to Use Unit has a recessed, hinged, front window of 0.25" (0.6cm) thick laminated safety glass with a 10.0" (25.4cm) access opening that enhances your mobility and depth of reach into the work area. Interior work area and tray are constructed of heavy-gauge, corrosion-resistant, type 304 stainless steel for easy cleaning. Voltage Compensating Speed Control ensures that the motor receives constant voltage when the power line voltage fluctuates, providing stable airflow and increasing laboratory, product, and personnel safety. Internal damper for balancing airflow is easily adjusted from within the work area and eliminates the need to decontaminate the unit before adjustment. Optional exhaust transition allows the cabinet to be vented externally. A facility exhaust blower is required. Carefully Directed Airflow Airflow descends from the top of the cabinet through a supply HEPA filter. As this vertical airstream approaches the work surface, the airflow splits. Approximately 50% is drawn into the cabinet s rear intake grille, and the rest meets ambient room air at the front intake grille. The air is then drawn into a plenum surrounding the work area by the blower located in the top of the cabinet. The blower pushes the air into a positive pressure plenum. The pressurized air is split, with 30% vented through the exhaust HEPA filter and the remaining 70% recirculated through the supply HEPA filter. 6 When space is limited, the Model 1118 is a practical choice when a clean air environment and product, personnel, and environment protection are required for working with agents assigned to biosafety levels 1, 2, or 3 in the absence of volatile toxic chemicals and volatile radionuclides. A1 BENCHTOP AIRFLOW Inflow velocity 75 FPM minimum 70% recirculated within the cabinet 30% exhausted Added protection positive pressure plenum is surrounded by negative pressure U.S. Patent held is 5,380,244. Ambient Air HEPA Filter Contaminated Air (positive pressure) Contaminated Air (negative pressure) HEPA Filtered Air

A1 Benchtop Specifications Model 2 Ft. Benchtop....... 1118 Work Area Width.............. 22.5"" (57.2cm) Height............. 26.5" (67.3cm) F-B................ 19.5" (49.5cm) Sash Opening........ 10.0" (25.4cm) Exterior Dimensions Width.............. 28.5" (72.4cm) Height............. 58.5" (148.6cm) F-B................ 27.5" (69.9cm), deduct 2.0" (5.1cm) from F-B for light canopy Electrical, Plug, Breaker, & Motor 1118............... 115V, 60 Hz, 6.7 FLA 115V............... Two NEMA 5-15P Plugs Breaker Requirement.. 15 Amp Motor.............. 1/3 HP Exhaust Requirements 1118............... 136-151 CFM* Canopy Exhaust (opt.). Add 30% to exhaust CFM Connection........ 8.0" (20.3cm) diameter duct connection, 0.25" w.g. psi drop at the connection Service Valve 1118............... 1, left side Additional Plugged Penetration 1118............... 1, left side Outlets 115V............... 1, on the control panel Unit Heat Load 115V............... 2500 BTUH (740 Watts) Weight Net................ 302 lbs. (137.0 kg) Shipping (Motor)...... 368 lbs. (166.9 kg) 220V, 50 Hz Model 1119 is available upon request (not UL Listed). *Cubic Feet per Minute (CFM) is based on the Direct Airflow Method, under clean conditions. Optional Fixed Height Modular Stand 191386 30.0"H (76.2cm) 191387 36.0"H (91.4cm) Minimum Height (Leveler In) Maximum Height (Leveler Out) Height No. 191386 No. 191387 No. 191386 No. 191387 Stand Height 25.5" (64.8cm) 31.5" (80.0cm) 26.8" (68.1cm) 32.8" (83.3cm) Work Surface Height 28.3" (71.9cm) 34.3" (87.1cm) 29.6" (75.2cm) 35.6" (90.4cm) Total Height of Cabinet with Stand 84.0" (213.4cm) 90.0" (228.6cm) 85.3" (216.7cm) 91.3" (231.9cm) 7

Features and Technical Specifications Forma Class II, A2 Biological Safety Cabinets A2 Benchtops: Flexible Use The Class II, A2 cabinet is a popular choice when a clean air environment and enhanced product, personnel, and environment protection are required for working with agents assigned to biosafety levels 1, 2, or 3. The cabinet may be vented directly into the lab in the absence of volatile toxic chemicals and volatile radionuclides. If connected to a properly functioning exhaust canopy, an A2 cabinet is suitable for work with minute quantities of volatile toxic chemicals and tracer amounts of radionuclides when required as an adjunct to microbiological studies. Greater Protection, Larger Work Area Frameless glass window ensures a clear, unobstructed view of the work area. Large 10.0" (25.4cm) sash opening enhances your mobility and depth of reach into the work area, while still providing maximum protection. The 49.0" (124.5cm) wide work area is 3.0" (7.6cm) larger than other major competitors, providing additional work space for your research. For additional product and personnel protection, unique, patented Vortex Channels create high velocity air at the window corners to move turbulent air into the return air system, reducing the risk of particulates escaping from or entering the cabinet work area. A 3/4 HP blower/motor provides enough reserve airflow capacity that our cabinet can accept up to a 230% increase in filter resistance and still meet NSF recommended airflow specifications, extending filter life and reducing maintenance costs. UV interlock provides additional safety by prohibiting UV light operation unless the sash is fully closed. Directed Airflow for a Sterile Work Area Airflow descends from the top of the cabinet through a supply HEPA filter. As this vertical airstream approaches the work surface the airflow splits. Approximately 50% is drawn into the cabinet s rear intake grille, and the rest meets ambient room air at the front intake grille. The air is then drawn into a plenum surrounding the work area by the blower located in the top of the cabinet. The blower pushes the air into a positive pressure plenum. The pressurized air is split, with 30% vented through the exhaust HEPA filter and the remaining 70% recirculated through the supply HEPA filter. 8 A2 BENCHTOP AIRFLOW Inflow velocity 100 FPM minimum 70% recirculated within the cabinet 30% exhausted Added protection positive pressure plenum is surrounded by negative pressure U.S. Patents held include 5,050,943; 5,295,902; 5,380,244; and 6,036,737. Ambient Air HEPA Filter Contaminated Air (positive pressure) Contaminated Air (negative pressure) HEPA Filtered Air

A2 Benchtop Specifications Models 4 Ft. Benchtop....... 1284 (1285) 6 Ft. Benchtop....... 1286 (1287) Work Area Width - 1284 (1285)... 49.0" (124.5cm) Width - 1286 (1287)... 73.0" (185.4cm) Height............. 28.4" (72.1cm) F-B................ 22.7" (57.7cm) Sash Opening........ 10.0" (25.4cm) Exterior Dimensions Width - 1284 (1285)... 54.0" (137.2cm) Width - 1286 (1287)... 78.0" (198.1cm) Height............. 64.0" (162.6cm), add 3.0" (7.6cm) for exhaust grille F-B*............... 32.5" (82.6cm) Electrical, Plug, Breaker, & Motor 1284............... 115V, 60 Hz, 13.5 FLA 1286............... 115V, 60 Hz, 13.8 FLA 1285............... 230V, 50 Hz, 9.6 FLA 1287............... 230V, 50 Hz, 7.5 FLA 115V............... NEMA 5-20P Plug 230V............... CEE 7/7 Plug Breaker Requirement.. 1284/1286: 20 Amp 1285/1287: 15 Amp Motor.............. 3/4 HP Exhaust Requirements 1284 (1285)......... 357-391 CFM** 1286 (1287)......... 530-580 CFM** Exhaust Requirements (continued) Canopy Exhaust (opt.). Add 30% to exhaust CFM Connection........ 8.0" (20.3 cm) diameter duct connection, 0.25" w.g. psi drop at the connection Service Valves 1284 (1285)......... 1, right sidewall 1286 (1287)......... 2, 1 on each sidewall Additional Plugged Penetrations 1284 (1285)......... 3, 1 on right and 2 on left sidewall 1286 (1287)......... 2, 1 on each sidewall Outlets 115V............... 2 GFIC protected duplex, 1 on each sidewall 230V............... 2, 1 on each sidewall Unit Heat Load 1284............... 2830 BTUH (830 Watts) 1285............... 3770 BTUH (1,110 Watts) 1286 (1287)......... 3600 BTUH (1,060 Watts) Weight Net 1284 (1285)........ 538 lbs. (244.0 kg) 1286 (1287)........ 720 lbs. (326.6 kg) Shipping (Motor) 1284 (1285)........ 735 lbs. (333.4 kg) 1286 (1287)........ 940 lbs. (426.4 kg) All units are UL Listed to United States and Canadian requirements and NSF Listed. *Remove light canopy, dress and control panels, and window channel for 28.0" (71.1cm) F-B. **Cubic Feet per Minute (CFM) is based on the Direct Airflow Method, under clean conditions. Optional Adjustable Modular Stand Stand is designed in accordance with American Disabilities Act (ADA) guidelines. Work surface height is adjustable in 1.0" (2.5cm) increments. 191550 For 4 Ft. A2 Units 191551 For 6 Ft. A2 Units 191684 Caster Dolly 9 An optional hydraulic crank-up stand is available. Refer to the Accessories for Biological Safety Cabinets section for details about that stand, drawer assemblies, etc. Height Minimum Height (Leveler In) Maximum Height (Leveler Out) Stand Height 23.4" (59.4cm) 32.7" (83.1cm) Work Surface Height 26.5" (67.3cm) 35.8" (90.9cm) Total Height of Cabinet with Stand* 90.4" (229.6cm) 99.7" (253.2cm) *Recommended minimum clearance is 5.0" (12.7cm) additional above the unit for certification (based on Direct Airflow Method).

Features and Technical Specifications Forma Class II, B2 Biological Safety Cabinets B2 Benchtops: The Ultimate Safeguard The Class II, B2 cabinet provides a clean air environment with maximum product, personnel, and environment protection from agents assigned to biosafety levels 1, 2, or 3. Total exhaust makes the B2 ideal for work when volatile toxic chemicals and radionuclides are required as an adjunct to microbiological studies. Maximum Protection, Customer Conveniences Cabinet s 12.0" (30.5cm) supply air intake and exhaust ducts include adjustable, zero leak dampers for easy, convenient connection to your in-house systems. Service valves can be plumbed from the side or rear of the cabinet for convenience, and all maintenance procedures can be performed from the front of the unit. Pressure differential switch continuously monitors the exhaust pressure for safety. In the event of inadequate exhaust, the pressure switch interrupts power to the supply blower/motor, preventing contaminated air from blowing onto you or into the lab. Exhaust failure alarm includes normally open, normally closed, and common remote alarm contacts to provide an output signal for remote monitoring capabilities via your in-house central alarm systems. Total Exhaust, Total Safety Room air is pulled into the cabinet by the blower and pushed through the supply HEPA filter, providing clean unidirectional air onto the work surface. Approximately 50% of this work area air exits through the rear grille. The remaining 50% meets room air and is pulled into the front intake grille, providing a protective barrier. The divided downflow and inflow air then combines and is pulled up the rear plenum through the exhaust HEPA filter by the facility exhaust system. 10 B2 BENCHTOP AIRFLOW Inflow velocity 100 FPM minimum 0% recirculated within the cabinet 100% exhausted Maximum protection unique design eliminates positive pressure contaminated plenum Ambient Air HEPA Filter Contaminated Air (negative pressure) HEPA Filtered Air U.S. Patent held is 5,380,244.

B2 Benchtop Specifications Models 4 Ft. Benchtop....... 1148 6 Ft. Benchtop....... 1168 Work Area Width - 1148......... 46.5" (118.1cm) Width - 1168......... 70.5" (179.1cm) Height............. 25.3" (64.3cm) F-B................ 25.0" (63.5cm) Sash Opening........ 8.0" (20.3cm) Exterior Dimensions Width - 1148......... 50.5" (128.3cm) Width - 1168......... 74.5" (189.2cm) Height............. 69.8" (177.3cm) F-B................ 35.6" (90.4cm), deduct 3.5" (8.9cm) for light canopy Electrical, Plug, Breaker, & Motor 1148............... 115V, 60 Hz, 6.0 FLA 1168............... 115V, 60 Hz, 10.0 FLA 115V............... Two NEMA 5-15P Plugs Breaker Requirement.. 15 Amp Motor.............. 1148: 1/3 HP 1168: 1/2 HP Exhaust Requirements* 1148............... 836-945 CFM 1168............... 1,165-1,332 CFM Exhaust Requirements (continued) Connection.......... 12.0" (30.5cm) diameter duct connection, 1.5" to 2.0" w.g. psi drop at the connection Service Valves 1148............... 1, right sidewall 1168............... 2, 1 on each sidewall Additional Plugged Penetrations 1148............... 3, 1 on right and 2 on left sidewall 1168............... 2, 1 on each sidewall Outlets 115V............... 2 duplex, 1 on each side wall Unit Heat Load 1148............... 370 BTUH (110 Watts) 1168............... 590 BTUH (170 Watts) Weight Net 1148............. 604 lbs. (274.0 kg) 1168............. 904 lbs. (410.1 kg) Shipping (Motor) 1148............. 750 lbs. (340.2 kg) 1168............. 1,100 lbs. (499.0 kg) Both units are UL Listed to Canadian requirements and NSF Listed. 220V, 50 Hz 4 ft. Model 1149 and 6 ft. Model 1169 are available upon request (not UL or NSF Listed). *Units require large volumes of supply and exhaust air, critical to the proper operation of the Class II, B2 cabinets. It is your responsibility to supply the correct volumes of make-up air. Cubic Feet per Minute (CFM) is based on a Pitot tube in the exhaust duct, under clean conditions. Optional Adjustable Modular Stand Stand is designed in accordance with American Disabilities Act (ADA) guidelines. Work surface height is adjustable in 1.0" (2.5cm) increments. 191580 For 4 Ft. B2 Units 191581 For 6 Ft. B2 Units 11 Refer to the Accessories for Biological Safety Cabinets section for information about drawer assemblies, etc. Height Minimum Height (Leveler In) Maximum Height (Leveler Out) Stand Height 23.4" (59.4cm) 32.7" (83.1cm) Work Surface Height 26.5" (67.3cm) 35.8" (90.9cm) Total Height of Cabinet with Stand* 93.2" (236.7cm) 102.5" (260.4cm) *Includes the height of the exhaust duct

Features and Technical Specifications Accessories for Biological Safety Cabinets Our biosafety cabinet accessories allow you to create a complete workstation that provides comfort and convenience as well as functionality. All accessories are customer installed unless noted otherwise. Hydraulic Crank-Up Stand for A2 Benchtops Vertical travel range is 7.0" (17.8cm). Levelers include 1.3" (3.3cm) of adjustment. Handle folds out of the way for convenience and safety. 191518 For 4 Ft. A2 Units 191519 For 6 Ft. A2 Units Ultraviolet (UV) Lights UV Light Assemblies 191418 15 Watt UV Light for 2 Ft. A1 Model 1118 191419 30 Watt UV Light for 4 and 6 Ft. A1, A2, and B2 Units Portable UV Lights 191069 15 Watt Portable UV Light for 2 Ft. A1 Model 1118 191070 30 Watt Portable UV Light for 4 and 6 Ft. A1, A2, and B2 Units Height Minimum Height (Leveler In) Maximum Height (Leveler Out) Stand Height 24.6" (62.5cm) 32.8" (83.3cm) Work Surface Height 27.6" (70.1cm) 35.8" (90.9cm) Total Height of Cabinet with Stand* 91.6" (232.7cm) 99.8" (253.5cm) *Recommended minimum clearance is 5.0" (12.7cm) additional above the unit for certification (based on the Direct Airflow Method). Drawers for A2 and B2 Benchtop Biosafety Cabinets 191494 Left Side, 4 Drawers for Adjustable Modular Stand (A2 and B2 units), 9.0"W x 18.0"H x 21.5"F-B (22.9cm x 45.7cm x 54.6cm) 191495 Right Side, 3 Drawers for Hydraulic Crank-Up or Adjustable Modular Stand (A2 and B2 units), 9.0"W x 18.0"H x 21.5"F-B (22.9cm x 45.7cm x 54.6cm) 191524 Left Side, 2 Drawers for Hydraulic Crank-Up Stand Only (A2 units), 9.0"W x 10.1"H x 21.5"F-B (22.9cm x 25.7cm x 54.6cm) 191591 Roller Base for Drawer Assembly, adds 3.0" (7.6cm) to the drawer assembly height, 9.4"W x 3.6"H x 21.9"F-B (23.9cm x 9.1cm x 55.6cm) 12

Exhaust Transitions Exhaust transitions with an 8.0" (20.3cm) diameter duct and zero leak damper allow you to vent your cabinet to the outside environment. 191217 Canopy Style Exhaust Transition without Damper for 2 Ft. A1 Model 1118 191478 Canopy Style Exhaust Transition with Zero Leak Damper for A1 Consoles 191782 Canopy Style Exhaust Transition with Zero Leak Damper for A2 Units Low Airflow Alarms Alarms include NO, NC, and COM dry contacts. Thru-Wall Port, and Service Valve and Piping Kits 191140 Extra Thru-Wall Port for All A1and B2 Units, specify left or right sidewall mount, factory installed 191275 Service Valve Kit for All Units, side mounted 191597 Service Valve Kit for A2 Units (used with No. 191620) 191620 Universal Piping Option for A2 Units, factory installed 800045 Rear Piping Kit for A1 Consoles and B2 Benchtops, includes street elbow and spacer ULPA Filters, factory installed 760190 Supply and Exhaust ULPA Filters for 4 Ft. A1 Consoles 760191 Supply and Exhaust ULPA Filters for 6 Ft. A1 Consoles 760192 Supply and Exhaust ULPA Filters for 4 Ft. A2 Units 760193 Supply and Exhaust ULPA Filters for 6 Ft. A2 Units 760197 Supply and Exhaust ULPA Filters for 4 Ft. B2 Units Additional Accessories 191168 120V, 50/60 Hz Low Airflow Alarm 191380 230V, 50/60 Hz Low Airflow Alarm IV Rods (complete with 4 hangers each) 191056 Ground Fault Interrupt (GFI) Duplex Receptacle for B2 Units 191127 Adjustable Footrest 191416 Locking Caster Set for A1 Consoles, adds 3.3" (8.4cm) to max. cabinet height 191486 Lab Chair with Arms, meets Class 1,000 clean air specifications 191487 Lab Chair without Arms, meets Class 1,000 clean air specifications 191496 ADA Control Panel for A2 Units, factory installed 191509 Armrest for 4 Ft. A2 Units 191512 Armrest for 6 Ft. A2 Units 6001284 IQ/OQ for Models 1148, 1168, 1200, 1214, 1284, and 1286 191190 IV Bag Hanger 191571 4 Ft. Rod 191572 6 Ft. Rod 191576 2 Ft. Rod 13

Features and Technical Specifications Forma Laminar Airflow Benchtop Workstations Laminar Airflow Benchtops: Product Protection Our horizontal laminar airflow benchtop workstations, often referred to as clean benches, create clean air for operations requiring a particlefree environment. These units meet requirements of Federal Standard 209E for Class 100 (M 3.5) clean air. Work surface and sidewalls are constructed of 16 gauge Type 304 stainless steel for durability and easy cleaning. Blower/motor automatically compensates for filter loading between annual certifications. Blower/motor switch, light switch, accessory receptacle, and receptacle for an optional UV light are located conveniently on the control panel. Built-in spill guard at the back of the work area protects the HEPA filter from spilled liquids, preventing filter damage and premature replacement. Units can be factory modified with reverse airflow to accommodate centrifuges, automated samplers, and other aerosol producing equipment. Contact our Custom Products Department. Carefully Directed Airflow Intake air passes through a 1.0" (2.5cm) fiberglass prefilter. The blower/motor unit moves the air through a zero-probed, HEPA filter rated at 99.99% efficient for 0.3 micron particulates. The HEPA filtered air is then directed horizontally across the work surface. Positive pressure, unidirectional laminar airflow prevents any inflow of room air contaminants onto the work surface. 14 Designed for Safety The workstation s design allows high velocity laminar air to travel across the work surface and past the operator. When various sized objects are placed within the work area, the airflow does not permit backwashing (i.e., contaminated outside air will not drift back into the work environment). All interior surfaces of the work area align with the edge of the HEPA filter media to provide true laminar airflow, preventing picture framing and backwashing of contaminated air and ensuring your product s safety. LAMINAR AIRFLOW BENCHTOPS Ambient Air HEPA Filtered Air Designed for lab procedures associated with the manipulation of non-hazardous materials, while maintaining a high quality environment of Class 100 (M 3.5) HEPA filtered air within the work area

Laminar Airflow Benchtop Specifications Models 3 Ft. Benchtop....... 1839 (1840) 4 Ft. Benchtop....... 1845 (1846)/1849 (1851) 6 Ft. Benchtop....... 1828 (1829) Work Area Width - 1839 (1840)... 34.5" (87.6cm) Width - 1845 (1846)/ 1849 (1851)........ 46.5" (118.1cm) Width - 1828 (1829)... 70.5" (179.1cm) Height - 1839 (1840)/ 1849 (1851)/ 1828 (1829)........ 28.4" (72.1cm) Height - 1845 (1846)... 34.4" (87.4cm) F-B................ 19.1" (48.5cm) Exterior Dimensions Width - 1839 (1840)... 37.0" (94.0cm) Width - 1845 (1846)/ 1849 (1851)........ 49.2" (125.0cm) Width - 1828 (1829)... 73.2" (185.9cm) Height - 1839 (1840)... 49.1" (124.7cm) Height - 1845 (1846)... 59.1" (150.1cm) Height - 1849 (1851)... 53.1" (134.9cm) Height - 1828 (1829)... 54.1" (137.4cm) F-B................ 34.0" (86.4cm) Electrical, Plug, Breaker, & Motor 1839............... 120V, 60 Hz, 7.0 FLA 1845/1828.......... 120V, 60 Hz, 12.0 FLA 1849............... 120V, 60 Hz, 9.0 FLA 1840/1851.......... 220V, 50 Hz, 9.0 FLA 1846/1829.......... 220V, 50 Hz, 11.0 FLA Electrical, Plug, Breaker, & Motor (continued) 120V............... NEMA 5-15P Hospital Grade Plug 220V............... CEE 7/7 Plug Breaker Requirement.. 15 Amp Motor.............. 1839 (1840)/1849 (1851): 1/3 HP 1845 (1846)/1828 (1829): 1/2 HP Penetrations All Models.......... 4, 2 on each sidewall Unit Heat Load 1839............... 2750 BTUH (810 Watts) 1840/1851.......... 6760 BTUH (1,980 Watts) 1845/1828.......... 4910 BTUH (1,440 Watts) 1846/1829.......... 8260 BTUH (2,420 Watts) 1849............... 3680 BTUH (1,080 Watts) Weight Net 1839 (1840)........ 190 lbs. (86.2 kg) 1845 (1846)/ 1849 (1851)...... 325 lbs. (147.4 kg) 1828 (1829)........ 430 lbs. (195.0 kg) Shipping (Motor) 1839 (1840)........ 290 lbs. (131.5 kg) 1845............. 420 lbs. (190.5 kg) 1846............. 440 lbs. (199.6 kg) 1849 (1851)........ 400 lbs. (181.4 kg) 1828 (1829)........ 530 lbs. (240.4 kg) 120V units are UL Listed to Canadian requirements. 220V, 50 Hz units and custom units are not UL Listed. Optional Modular Stand 191400 30.0"H (76.2cm) for 3 Ft. Units 191402 30.0"H (76.2cm) for 4 Ft. Units 191398 30.0"H (76.2cm) for 6 Ft. Units 191401 36.0"H (91.4cm) for 3 Ft. Units 191403 36.0"H (91.4cm) for 4 Ft. Units 191399 36.0"H (91.4cm) for 6 Ft. Units 15 Total Cabinet Height With 30.0 Stand Total Cabinet Height With 36.0 Stand Model Minimum Ht.* Maximum Ht.** Minimum Ht.* Maximum Ht.** 1839 (1840) - 3 Ft. 77.6" (197.1cm) 78.9" (200.4cm) 83.6" (212.3cm) 84.9" (215.6cm) 1845 (1846) - 4 Ft. 87.6" (222.5cm) 88.9" (225.8cm) 93.6" (237.7cm) 94.9" (241.0cm) 1849 (1851) - 4 Ft. 81.6" (207.3cm) 82.9" (210.6cm) 87.6" (222.5cm) 88.9" (225.8cm) 1828 (1829) - 6 Ft. 82.6" (209.8cm) 83.9" (213.1cm) 88.6" (225.0cm) 89.9" (228.3cm) *Minimum height = levelers in; minimum height to the work surface is 29.4" (74.7cm) for the 30.0" stand and 35.4" (89.9cm) for the 36.0" stand **Maximum height = levelers out; maximum height to the work surface is 30.7" (78.0cm) for the 30.0" stand and 36.7" (93.2cm) for the 36.0" stand

Features and Technical Specifications Forma Laminar Airflow Console Workstations Laminar Airflow Consoles: Product Protection in Easy-to-Install, One-Piece Construction Our horizontal laminar airflow console workstations, often referred to as clean benches, create clean air for operations requiring a particle-free environment. These units meet requirements of Federal Standard 209E for Class 100 (M 3.5) clean air. All interior surfaces of the work area align with the edge of the HEPA filter media to provide true laminar airflow, preventing picture framing and backwashing of contaminated air and ensuring your product s safety. Work surface and sidewalls are constructed of 16 gauge Type 304 stainless steel for durability and easy cleaning. Blower/motor automatically compensates for filter loading between annual certifications. Blower/motor switch, light switch, accessory receptacle, and receptacle for an optional UV light are located conveniently on the control panel. Built-in spill guard at back of the work area protects the HEPA filter from spilled liquids, preventing filter damage and premature replacement. Casters provide easy mobility for cleaning or moving. Leveling feet are included for stability when positioned in a final location. Units can be factory modified with reverse airflow to accommodate centrifuges, automated samplers, and other aerosol producing equipment. Contact our Custom Products Department. 16 Designed for Safety The workstation s design allows high velocity laminar air to travel across the work surface and past the operator. When various sized objects are placed within the work area, the airflow does not permit backwashing (i.e., contaminated outside air will not drift back into the work environment). Low overall height permits easy passage through doorways and accommodates sites where ceiling height is limited. Carefully Directed Airflow Intake air passes through a 1.0" (2.5cm) fiberglass prefilter. The blower/motor unit moves the air through a zero-probed, HEPA filter rated at 99.99% efficient for 0.3 micron particulates. The HEPA filtered air is then directed horizontally across the work surface. Positive pressure, unidirectional laminar airflow prevents any inflow of room air contaminants onto the work surface. LAMINAR AIRFLOW CONSOLES Designed for lab procedures associated with the manipulation of non-hazardous materials, while maintaining a high quality environment of Class 100 (M 3.5) HEPA filtered air within the work area Ambient Air HEPA Filtered Air

Laminar Airflow Console Specifications Models 4 Ft. Console........ 1852 5 Ft. Console........ 1854 6 Ft. Console........ 1856 (1857) Work Area Width - 1852......... 48.3" (122.7cm) Width - 1854......... 60.3" (153.2cm) Width - 1856 (1857)... 72.3" (183.6cm) Height............. 32.0" (81.3cm) F-B................ 21.0" (53.3cm) Exterior Dimensions Width - 1852......... 52.0" (132.1cm) Width - 1854......... 64.0" (162.6cm) Width - 1856 (1857)... 76.0" (194.0cm) Height............. 74.6" (189.5cm) F-B................ 34.0" (86.4cm) Penetrations All Models.......... 4, 2 on each sidewall Unit Heat Load 1852............... 3890 BTUH (1,140 Watts) 1854/1856.......... 4910 BTUH (1,440 Watts) 1857............... 8260 BTUH (2,420 Watts) Weight Net 1852............. 470 lbs. (213.2 kg) 1854............. 550 lbs. (249.5 kg) 1856 (1857)........ 610 lbs. (276.7 kg) Shipping (Motor) 1852............. 590 lbs. (267.6 kg) 1854............. 680 lbs. (308.4 kg) 1856............. 775 lbs. (351.5 kg) 1857............. 800 lbs. (362.9 kg) Electrical, Plug, Breaker, & Motor 1852............... 120V, 60 Hz, 9.5 FLA 1854/1856.......... 120V, 60 Hz, 12.0 FLA 1857............... 220V, 50 Hz, 11.0 FLA 120V............... NEMA 5-15P Hospital Grade Plug 220V............... CEE 7/7 Plug Breaker Requirement.. 15 Amp Motor.............. 1852: 1/3 HP 1854/1856: 1/2 HP 1857: 3/4 HP 120V units are UL Listed to Canadian requirements. 220V, 50 Hz units and custom units are not UL Listed. 17

Features and Technical Specifications Accessories for Laminar Airflow Workstations Our laminar airflow cabinet accessories allow you to create a complete workstation that provides comfort and convenience as well as functionality. All accessories are customer installed unless noted otherwise. Ultraviolet (UV) Lights UV Light Assemblies 191075 15 Watt UV Light for 3 Ft. Model 1839 191481 15 Watt UV Light for 3 Ft. Model 1840 191076 30 Watt UV Light for 4, 5, and 6 Ft. Units Portable UV Lights 191069 15 Watt Portable UV Light for 3 Ft. Model 1839 191070 30 Watt Portable UV Light for 4, 5, and 6 Ft. 120V Units Receptacles with Cover(s), factory installed 191109 120V NEMA 5-15R Ground Fault Circuit Interrupter (GFCI) Duplex Receptacle, right side 191110 120V Sidewall Mounted NEMA 5-15R Duplex Receptacle, right side Additional Accessories 191009 Plexiglas Side Panel for Consoles, factory installed 191253 Service Valve Kit 191055 Magnehelic Pressure Gauge, factory installed 191236 Storage Bin Kit for Consoles, attaches beneath the work surface 191127 Adjustable Footrest 191486 Lab Chair with Arms, meets Class 1,000 clean air specifications 191487 Lab Chair without Arms, meets Class 1,000 clean air specifications IV Rods (complete with 4 hangers each) 18 191057 Rod for All Benchtops (Model 1828 (1829) requires 2) 191121 Rod for 5 Ft. Console Model 1854 191227 Rod for 6 Ft. Console Model 1856 (1857) 191228 Rod for 4 Ft. Console Model 1852 Portable Microscope Stand Stand fits inside the workstation yet is independent of the cabinet. Table surface is free from vibration and protected by Class 100 (M 3.5) HEPA filtered air. 191586 18.0" x 18.0" (45.7cm x 45.7cm) Stainless Steel Platform, height is adjustable from 32.0" to 41.0" (81.3cm to 104.1cm) in 1.0" (2.5cm) increments

Recognized Worldwide for Quality, Safety, and Service Forma Biological Safety Cabinets and Laminar Airflow Workstations are manufactured to conform with our Continual Improvement guidelines. Our commitment to you is reinforced by our adherence to world quality and safety standards. cul Listing, culus Listing, and NSF Listing cul and culus Listings attest to the electrical and mechanical safety of our biosafety cabinets and laminar airflow workstations, as applicable. NSF International Listing attests to the containment and performance capabilities of our biosafety cabinets. Factory Pre-Test Before shipment, each Forma Biological Safety Cabinet and Laminar Airflow Workstation undergoes a number of tests to ensure that the unit operates as designed and meets or exceeds required specifications. These tests include visual inspection, electrical safety, unit performance, HEPA filter integrity, cabinet integrity, and airflow specifications. A copy of the test report is supplied with each biological safety cabinet and laminar airflow workstation. 3 Year Warranty Protection We confidently back our biological safety cabinets and laminar airflow workstations with a three year warranty on parts and labor, enabling us to offer one of the most comprehensive warranties in the industry. Call our Services Department or your local international distributor for details. Unmatched Laboratory Services Our support continues after the point-of-purchase. A worldwide network is ready to support your specific and unique needs. Some of the laboratory services offered include the following: Consultation Extended Warranties Preventive Maintenance Agreements Replacement Parts Repair Services Contact Us Training Calibration Installation Proof of Performance Qualification/Validation Datalogger Systems Our Sales Support Department (toll free 866-9-THERMO) is available from 8:00 a.m. to 6:00 p.m. (ET). International customers may call 740-373-4763 for Sales Support from 8:00 a.m. to 4:30 p.m. (ET). For details about our laboratory services, contact the Services Department (toll free 888-213-1790) from 8:00 a.m. to 6:00 p.m. (ET) or e-mail help@thermolabservices.com. International customers should contact their authorized local distributor for information about available services. ISO 9001: A Commitment to Excellence As an innovative, global leader, we continue the pursuit of excellence by maintaining ISO 9001 registration. This advanced quality system reinforces our commitment to provide the highest quality products available. 19 The ISO 9000 series is a set of international requirements for establishing and maintaining quality management systems. Continued compliance is assured by ongoing internal audits and periodic audits by the assessing agency. We are proud to be ISO 9001 registered.

People of Science Working with People of Science A Leader in Controlled Environment Equipment Whether you are storing, preparing, culturing, or analyzing samples, Thermo has the research tools you depend on to succeed in the lab. We have been providing high quality, reliable controlled environment laboratory products for a wide variety of clinical, educational, biotechnological, pharmaceutical, and industrial applications for more than 50 years. We offer the following: Forma Cell Culture Incubators Forma In Vitro Fertilization (IVF) Incubators and CryoMed Controlled Rate Freezers Forma Environmental Chambers Forma Ultra-Low Temperature Freezers Forma Laminar Airflow Equipment Forma Biological Safety Cabinets Forma Cryopreservation Equipment Forma Blood Bank Equipment Forma Circulating Baths Forma Monitor/Alarm System Forma Orbital Shakers Forma Programmable Centrifuges Forma Lab Washers/Dryers Forma Lab Refrigerators Forma Lab Freezers Forma Chromatography Refrigerators Custom-Designed Equipment Laboratory Services One Convenient Source, Total Solutions Thermo s expertise extends beyond controlled environment equipment. In fact, you may be surprised by the breadth of products and services we offer. Our life and laboratory sciences and services, optical technologies, measurement and control, turnkey operations, and even capital equipment financing specialists are eager to share their knowledge and work as your partner...for life. The benefit? We re people of science working with people of science. And you will quickly discover the value of one convenient source providing total solutions tailored to your specific needs. About Thermo A world leader in high-tech instruments, Thermo Electron Corporation helps life science, laboratory, and industrial customers advance scientific knowledge, enable drug discovery, improve manufacturing processes, and protect people and the environment with instruments, scientific equipment, and integrated software solutions. Based in Waltham, Massachusetts, Thermo Electron has revenues of more than $2 billion, and employs approximately 11,000 people in 30 countries worldwide. For more information, visit www.thermo.com 2003 Thermo Electron Corporation. All rights reserved. Minihelic is a registered trademark of Dwyer Instruments, Inc. Plexiglas is a registered trademark of Rohm & Haas Corporation. All other trademarks and registered trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Rev. 0, 08/03 10M Controlled Environment Equipment P.O. Box 649 Marietta, OH 45750 740-373-4763 Fax: 740-373-6770 Toll Free USA and Canada 866-984-3766 www.thermo.com/forma