FOR YOUR PERMANENT FILE

Similar documents
FOR YOUR PERMANENT FILE

DIGITAL TORQUE WRENCH. Useful Instructions

Digital Electronic Torque Wrench. Operating Manual. Model 60648

TOOLS TORQUE. The information in this chapter is organized as follows:

Digital Torque Wrench

A Division of Snap-on Logistics Company

NEW! NEW! 1/2" DRIVE 12 POINT DEEP IMPACT SOCKETS. TRADE KITS Get your work done faster, easier and safer REVERSIBLE RATCHETING COMBINATION WRENCHES

MN-IST-SD SERIES-E. IST-SD SERIES DIGITAL TORQUE SCREWDRIVER OPERATION MANUAL

AXD 530 MicroManometer

Operating and Service Manual 1250-Series Exacta 2 Digital Torque Wrench

NEW! NEW! 1/2" DRIVE 12 POINT DEEP IMPACT SOCKETS. TRADE KITS Get your work done faster, easier and safer REVERSIBLE RATCHETING COMBINATION WRENCHES

NEW! NEW! 1/2" DRIVE 12 POINT DEEP IMPACT SOCKETS. TRADE KITS Get your work done faster, easier and safer REVERSIBLE RATCHETING COMBINATION WRENCHES

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Micrometer Torque Wrenches Beam Torque Wrenches Electronic Torque Wrenches

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

PORT-A-WEIGH CRANE SCALES

Hand Held Pull Tester Instruction Manual Order No

Torque Wrenches

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

B-RAD Select USER MANUAL TABLE OF CONTENTS

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Sales Blaster nd Quarter

FIRST FOR PROFESSIONALS

5% 325 1/4 1/ x 12. mm x 18. mm 323 3% 324. Torque Wrenches

Model 7400 OPERATOR MANUAL

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Sales Blaster rd Quarter

Compact Scales. Software Revision V1.25 & above

Non-Contact Phase Rotation Tester

Cole-Parmer Pro-Spense

WARNING ATTENTION. Please read this information carefully before operating your safe.

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

OPERATING INSTRUCTIONS

MoistureMatch A next generation grain tester

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

Model 8000XL OPERATOR MANUAL

AWS-1025, 1075 & Torque Wrench Loaders Use with QC, MTM & Bench Stand Transducers

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

OPERATING INSTRUCTIONS

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

3000 SERIES DRY-BLOCK HEAT SOURCE

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

SPC Series. Digital Scale. Operation Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Model Insulation Tester / Megohmmeter. User Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

SERIES OPERATION AND MAINTENANCE MANUAL

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Dial Wrench Operating Instructions Rev 2.6 (4/10/17)

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

PTC8001 Temperature Calibrator

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

OPERATING MANUAL TS - 4 Thermal Microscope Stage

User's Manual. Earth Ground Resistance Tester. Model Introduction

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Visit us at

DIGITAL TORQUE GAUGE MODEL BTGE-G

! Warning, refer to accompanying documents.

Model 700 Microarray Oven

OPERATION AND MAINTENANCE MANUAL

IMPORTANT RECEIVING INSTRUCTIONS:

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

FlexChem Model 404 Rotating Oven

STAINLESS STEEL LCD DIGITAL SCALE

Automatic Electric Jack Leveling

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

AXD 510 MicroManometer

INSTRUCTION MANUAL DM5B Fax: (503)

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench


EGOLD-1000 Electronic Grease Level Detector

ReadStar & CapStar Range Torque Readouts & Torque Testers. Crane Electronics Inc The force in torque management

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Customer Service / Repairs. Ordering Replacement Parts. Contact Information

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Blue Jay Rodless Cylinder BC MS. Track Repair Manual 1996 & 2012 THE EASTMAN EASTMAN. All End Caps Black for Models

Torque Test Stands Series TS MODELS TST / TSTH & TSTM / TSTMH. User s Guide

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

LED-HL2-CMP LED Headlight System Operation Manual

STP116 STP188. Tyre Pressure Monitoring System. User manual

Instruction Manual. Square Drive Hydraulic Torque Wrenches Model TW Series. Maximum Operating Pressure 700 bar

Intelligent Electronic Safe

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

IBT Series Square Drive Torque Wrenches

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Transcription:

FOR YOUR PERMANENT FILE WRENCH MODEL NUMBER: operation manual computorq 3 electronic WRENCH WRENCH SERIAL NUMBER: For Warranty Claims, Contact CDI Torque Products at (626) 965-0668. LIMITED WARRANTY The CDI Computorq 3 Electronic Torque Wrench is backed by a one year warranty. This warranty covers manufacturer defects and workmanship. The warranty excludes misuse, abuse and normal wear and tear. Exclusion is not allowed in some states and may not apply. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. IMPORTANT ENVIRONMENTAL NOTES: 1. This equipment may contain hazardous materials which can be harmful to the environment. 2. Do not dispose of this equipment as municipal waste. Return it to the distributor or a designated collection center. Thank you for caring about our environment! 19220 SAN JOSE AVENUE CITY OF INDUSTRY, CA 91748 USA (626) 965-0668 Find other fine torque products at WWW.CDI.COM Form 20-1800-CDI 6/2010 Rev. N/C Made in USA with US and Global Components

SAFETY MESSAGES SAFETY MESSAGES WARNING - Risk of flying particles Over-torquing can cause breakage. Force against flex stops on flex head can cause head breakage. An out of calibration angle wrench can cause part or tool breakage. Broken hand tools, sockets or accessories can cause injury. Excess force can cause crow foot or flare nut wrench slippage. READ THIS MANUAL COMPLETELY BEFORE USING THE CDI Computorq 3 WRENCH To insure accuracy, work must not move in angle mode. For personal safety and to avoid wrench damage, follow good professional tool and fastener installation practices. Periodic recalibration is necessary to maintain tool accuracy. USERS AND BYSTANDERS SHOULD ALWAYS WEAR EYE PROTECTION Be sure all components, including adapters, extensions, drivers and sockets are rated to match or exceed the torque being applied with tool. Observe all equipment, system and manufacturer s warnings, cautions and procedures when using this wrench. Always use the correct size socket for the fastener being torqued. Do not use damaged sockets, showing signs of wear or cracks. Always replace damaged fasteners before applying torque. WARNING - To avoid damaging Computorq 3 Wrench Never operate wrench when powered OFF. Always power wrench ON prior to applying torque. Do not press ON/ZERO key while torque is being applied. Never use this wrench to loosen fasteners. Never use extensions, such as a pipe, on the handle of the wrench. Always make sure the ratchet Forward/ Reverse Switch is fully engaged in the correct position. Always verify that the wrench capacity matches or exceeds each application before proceeding. Always verify the calibration of the wrench if you know or suspect its capacity has been exceeded. Never force the head of flex head drives against stops. Always pull - do not push - on the wrench handle and adjust your stance to prevent a possible fall while applying torque. WARNING - Electrical Shock Hazard Electrical shock can cause injury. Plastic handle is not insulated. Do not use on live electrical circuits. MAINTENANCE / SERVICE 1. IMPORTANT - Service, repair and calibration are to be performed by CDI Torque Products only. Calibration by the user is recorded in the wrench and voids factory certification. 2. The torque wrench s internal mechanism is permanently lubricated during assembly. Do not attempt to lubricate the internal mechanism. 3. To safely clean the torque wrench, wipe with a damp cloth. NEVER use solvents, thinners, or engine cleaners of any kind. NEVER immerse the torque wrench in liquids of any kind. 4. Store torque wrench in protective tube at its lowest torque setting. Do not force handle below lowest setting.

introduction The Computorq 3 Electronic Torque Wrench digitally displays fastener torque specification settings, torque readings and peak hold measurements. DISPLAY - The wrench features a custom LCD display, use keypad to select torque units, readout in ft.lb., in.ib., Nm, and kg.cm. Display also includes a 10 segment bar graph. SETTING - Determine torque specification for fastener. Next, use the UP or DOWN arrow keys to scroll to the desired target torque value. NOTE: The target torque value is adjustable between 10% and 100% of full scale. The scrolling display rolls over at both ends for quick and convenient adjustment of setting. TRACKING - While torque is applied, the display switches from preset value to actual applied value with a 0.20 second update rate. BATTERY - The Computorq 3 uses two (2) standard replaceable CR123 lithium cells which provide more than 80 hours of continuous operation. The current battery level can be determined by viewing the battery indicator icon in the upper left corner of the LCD display. A flashing batt display means the wrench is no longer accurate and the battery must be replaced before continuing usage of wrench. POWER ON - Depress and hold the ON/ZERO key until display illuminates. POWER OFF - Depress the ON/ZERO key and hold for 5 seconds. AUTO POWER OFF - Auto power OFF will occur after 2 minutes of nonusage to conserve battery power. AUDIBLE TONES AND LED S - When the applied torque value equals -10% of the target torque value, a YELLOW LED illuminates. When the target torque value is reached, the wrench outputs a 0.50 (1/2) second audible tone and the GREEN LED illuminates. At +10% of target torque the RED LED illuminates. PEAK HOLD - When torque is released the display holds and flashes the peak torque reading for 10 seconds or until next torque is applied. OVERLOAD - If the wrench is used beyond 100% of full scale the audible tone will pulse rapidly to warn the operator to stop. At 125% of full scale the display will lock and read - - - -. ZERO - Wrench will automatically perform self calibration check and re-zero when powered ON. When powered ON, the wrench can be re-zeroed at any time by depressing the ON/ZERO key. SETUP MEMORY - When powered ON, the wrench returns to the last unit and torque setting selected. The yellow LED illuminates when the applied torque value equals -10% of the target torque value. The green LED illuminates when the target torque value is reached and the wrench outputs a 0,50 (1/2) second audible tone. The red LED illuminates at +10% of target torque, indicating fastener was overtorqued. Rapid alarm buzzer sounds.

operator instruction BATTERY INDICATOR AUDIBLE ALERT BAR GRAPH CCW INDICATOR UNITS OF MEASURE READING UPDOWN PRESET LIGHT BAR UNIT SELECTION POWER ON/ZERO SET-UP: 1. To power wrench ON, depress the ON/ZERO key - the wrench will seft-test and display the last unit and torque setting selected. 2. Select the desired units by depressing the UNITS key. Each time the UNITS key is depressed, a different unit of measure is displayed - (ft.lb., in.lb., Nm, or kg.cm.) 3. Pre-select desired torque value by depressing and holding the UP ( ) or DOWN ( ) key. The scrolling display rolls over at both ends for quick and convenient adjustment of setting. 4. Tool set-up is complete, wrench is ready for use. IMPORTANT: Proper hand position when grasping wrench is necessary to ensure highest wrench accuracy. Position hand so that it is centered on the gripped portion of handle. AVOID GRASPING WRENCH ABOVE OR BELOW GRIPPED PORTION OF HANDLE. USAGE: 1. Begin torquing fastener using a pulling motion. 2. The display will track the applied torque. 3. Stop application of torque when half-second audible tone is heard and GREEN LED illuminates, If RED LED illuminates, preset torque value has been exceeded.when this occurs the operator must loosen fastener and repeat torque application. NOTE: LED will illuminate when 90% of desired preset value has been achieved. 4. On release the PEAK (highest torque value applied)* will be displayed, flashing for 10 seconds or until torque is reapplied. *The PEAK torque reading will tell you if excess torque has been applied. This feature can be used to improve you wrenching technique for best accuracy. use of adapters, 100% extensions 100% 30% 30% 5% 5% and universals Anytime an adapter, extension or universal is used with a torque wrench in such a way that the fastener distance is different that the torque wrench square drive distance, an adjustment to the set torque is required to get proper fastener torque. Square Drive Square Drive Square Drive Torque Settings/Reading = Force x Distance Torque Torque Wrench Square Drive Distance = A Torque Settings/Reading Settings/Reading = Force = Force x Distance x Distance Torque Torque Wrench Wrench Square Square Drive Drive Distance Distance = A = A Fastener torque equals torque wrench square drive torque. Wrench setting is equal to desired fastener torque. REPLACE REPLACE BATTERY BATTERY Set Torque = Fastener Torque Set Torque Set Torque = Fastener = Fastener Torque Torque Fastener torque equals torque wrench square drive torque. Wrench setting is equal to desired fastener torque. Fastener Fastener Torque Set Torque Set Torque = Torque = x A x A A + BA + B Torque Wrench Square Drive Distance = Fastener Torque Wrench Square Drive Distance = A Fastener A Distance Distance = B = B Fastener torque is greater than torque wrench square drive torque. Calculated setting will be lower that desired fastener torque. Fastener Fastener Set Torque Set Torque = Fastener Fastener = Torque Torque x A Distance Distance = B = B x A A + BA + B Torque Torque Wrench Wrench Square Square Drive Drive Distance Distance = A = A Fastener torque is less than torque wrench square drive torque. Calculated setting will be higher than desired fastener torque. When using a universal or 15 15 wobble extension, do not exceed more than 15 15 15 For Angles For Angles Less Less Than Than 15 Degrees 15 Degrees Set Torque Set Torque = Fastener = Fastener Torque Torque (approximately) (approximately) degrees & offset DO NOT DO NOT EXCEED EXCEED 15 DEGREES 15 DEGREES from perpendicular drive. Do not use long extensions with the flex-drive. Force Force Force

specifications DISPLAY - 4-digit LCD, low battery indicator. SETTING - Displayed with no torque applied. TRACKING - Real time display with torque applied. PEAK - Displayed value flashes for 10 seconds at torque release. DISPLAY CAPACITY - 8,000 counts CW/CCW torque from 10% to 125% of full scale. ACCURACY (72 F) CW CCW +/-2% +/-3% of reading, 20% to 100% of full scale +/-4% +/-6% of reading, 10% to 19% of full scale DIMENSIONS Part Number DRIVE LENGTH WEIGHT 2401CI3 1/4 15 in. 2.0 lbs. 1002CF3 3/8 17 in. 2.2 lbs. 2503CF3 1/2 27 in. 3.5 lbs. SEALED KEY PAD ON/ZERO - power on - auto self check - zero UP - (+) increases torque setting DOWN - (-) decreases torque setting UNITS - selects ft.lb., in.lb., Nm or kg.cm. specifications MODEL 2401CI3 1002CF3 2503CF3 Drive 1/4 3/8 1/2 ft.lb. 2.0-20.0 5.0-100.0 25-250 in.lb. 24-240 120-1200 300-3000 Nm 2.71-27.10 13.6-135.6 33.8-338 kg.cm. 27.6-276 138-1382 345-3456 PLEASE NOTE 1. CALIBRATION - Contact CDI Torque Products for calibration services. 2. EQUIPMENT REQUIRED - Precision test bars and certified calibration weights or another torque source, accurate to 1/2% of reading. 3. NOTES - If the display shows Err0 at power on, the wrench is damaged and must be returned to CDI Torque Products for repair. - Remove battery when stored for extended periods. 4. BATTERY REPLACEMENT - Replace with two (2) CR123 Lithium cells only (available anywhere). To replace battery, remove cover on underside of handle (opposite display). OPERATING TEMPERATURE: 40 to 110 F (5 to 42 C) STORAGE TEMPERATURE: -1 to 122 F (-20 to 50 C) HUMIDITY - up to 90% non-condensing BATTERY - Two (2) CR123 Lithium cells, over 80 hours continuous operation. AUTO SHUT-OFF - Auto power OFF will occur after 2 minutes of non-usage to conserve battery power. 100% 30% 5% REPLACE BATTERY

CERTIFICATION This torque wrench as calibrated at the factory, is certified to meet the current ASME specification. Additionally, all wrenches are calibrated on a torque standard traceable to the National Institute of Standards and Technology (N.I.S.T.). conversion table To Convert Multiply From To By in. oz. in. lb. 0.06250 in. lb. in. oz. 16 in. lb. ft. lb. 0.08333 in. lb. cmkg 1.15212 in. lb. mkg 0.01152 in. lb. Nm 0.11298 in. lb. dnm 1.12984 ft. lb. in. lb. 12 ft. lb. mkg 0.13825 ft. lb. Nm 1.35581 dnm in. lb. 0.88507 dnm Nm 0.1 Nm dnm 10 Nm cmkg 10.1971 Nm mkg 0.10197 Nm in. lb. 8.85074 Nm ft. lb. 0.73756 cmkg in. lb. 0.86796 cmkg Nm 0.09806 mkg in. lb. 86.7961 mkg ft. lb. 7.23301 mkg Nm 9.80665 use of extensions and adapters When using an extension or adapter (increasing the effective length of the torque wrench) the output torque value will change. To calculate the new torque output of the wrench use the following formula: TA = Torque exerted @ end of adapter L = Distance between square drive and hand position TW = Wrench scale reading A = Length of adapter or extension TA A TW = TA x L L + A A number of variables can affect torque accuracy. These include the length of an adapter or extension, length of the wrench and variations in hand position on the wrench will affect the accuracy of the above calculation. L NOTES TW