Manual Scale PCE-BT 200 / 2000

Similar documents
Manual Balanza dosificadora PCE-ABZ 200C


Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

OVERVIEW OF CONTROLS

Adam Equipment CPW COMPACT SCALE

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

CITIZEN. series. Precision Balances

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Virtual Measurements & Control. VC210 Operators Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

GRAVITY MEASUREMENT, INC.

Compact Scales. Software Revision V1.25 & above

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Manual Thickness gauge PCE-CT 30

SPC Series. Digital Scale. Operation Manual

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

Valor 2000 Series Instruction Manual

Adam Equipment CBK SERIES

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Adam Equipment AE 401 INDICATORS. (P.N. 9520, Revision B3, September 2008)

NCSA 20plus Service Manual

WARRIOR SERIES USER MANUAL

Service manual Precision balance

SSP-Series Portable Balances Operation Manual

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

This document is hosted by Old Will Knott Scales GBK and GFK Series

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

CED PRO II. High Precision Electronic Scale Instructions

OCS-T High Resolution Digital Crane Scale

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Weighing Scale IDS-802. User Manual

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Operating instructions Platform/floor scales

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

Switching DC Power Supply

PCE-CS 300. Crane Scales up to 300 kg ( 661 lb)

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

This document hosted by: Operating Manual. Economical Precision Balances. CZ Series

ECONOMISER SERIES E2T USER MANUAL

Weighing Indicator TM701 Handrail scales

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0

XK3190- A7. Weighing indicator USER MANUAL

Quick Guide. brite Advanced Retail scale

Adam Equipment. GBK and GFK Series. (P.N , Revision D, August 2011)

Manual KREBS Viscometer PCE-RVI 5

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Navigator TM Series Balances Instruction Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Manual Calibrator PCE-IC1

Welch Allyn Non-Masted Scales

KANEAUTO 4-4 & KANE AUTO 5-4

Operating manual Platform/floor scales

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

KERN HFM Version /2010 GB

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

Operating Instructions Precision balance

User Manual Rittal PMC UPS 6kVA

Assembly instructions WAES

TABLE OF CONTENTS 1 - GENERAL...3

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

PLATINUM. PREMIUM CLASS pocket scale. Manual & Operation Guide

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

UK Weighing Federation Technical Articles

LE.3k Operation Manual

OIML CERTIFICATE OF CONFORMITY

B-RAD Select USER MANUAL TABLE OF CONTENTS

Ohaus ES Series Bench Scale

Top quality For industrial use

EC200 ELECTRONIC CONTROL SYSTEM

Operating manual Multi-function weighing balance

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Defender 3000 Series Base Instruction Manual

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

OCS Series. High Resolution Digital Crane Scale. User Guide

Patient Lift Scale Indicator Owner s Manual

BRAKE TESTER DECELEROMETER

Operating manual Medical Stand assist scales

Operating instruction Compact balance

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

OPERATING MANUAL EARTH RESISTANCE METER MRU-20

Installation information. METTLER TOLEDO IND425 / IND435 / IND445 / IND465 terminals

uline.com

Transcription:

www.pce-industrial-needs.com ursdale echnical Services Ltd Unit N12B ursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ Manual Scale PCE-B 200 / 2000

1. Introduction Electrical balance B series are designed for use in laboratories and many others technical applications, where high measurements precision is not required. All balances are metrologically tested by manufacturer and they are not designed for calibration certificate. According to order, balances may be calibrated. Balances classification (PKWiU code) 33.20.31. 2. Completation Basic set includes: 1. Balance, 2. Pan cover with lid (5 parts), 3. Power supply unit, 4. Accumulators 6 units (option) 5. Decorating button (option) 6. Instruction manual. 7. Warranty. 3. Security rules o avoid electrical shock or damage of the balance or connected peripheral devices, it is necessary to follow the security rules below. All repairs and necessary regulations can be made by authorised personnel only. o avoid fire risk use a feeder of an appropriate type (supplied with the balance). Pay attention that supply voltage is compatible with specified technical data. Do not use the balance when its cover is opened. Do not use the balance in explosive conditions. Do not use the balance in high humidity. If the balance seems not to operate properly, unplug it from the mains and do not use until checked by authorised service. According to legal regulations it if forbidden to dispose electronic equipment in waste containers. Please return wasted balance to the point of purchase or other company specialised in recycling of wasted electronic components. 2

4. echnical data Model of scale B200 B2000 Capacity (Max) 200g 2000g Reading unit (d) 0,001g 0,01g Linearity 0,003g 0,03g Repeatablity 0,003g 0,03g Pan dimension φ115mm 145x125mm Working temperature +18 C +33 C Weighing time <3s Scale dimensions 175x245x80mm Scale weight 1kg Power supply =12V 160mA Accumulators NIMH R3 ( AAA size) 6pcs Working time with 1000mAh batteries ~6 h (back light on) ~16h (back light off) Batteries charge indicator (battery function) Automatic shut-off time > 5 min (AutoOFF function) Automatic back light shut-off time > 30 s (b_light function) Calibration weight (OIML) F2 200g F2 2000g 5. General view of balance 9 11 12 10 6 1 2 8 5 1 pan welt (pan) 2 carring pan ( under welt) 3 information windows 4 LCD display 5 balance keyboard 6 rotary legs 7 level 8 pan cover (complex) 9 keyboard cover 10 protection rod 11 protection cap 12 decorating button 4 7 9 1 2 8 3 5 1 pan welt (Pan) 2 carring pan (under welt) 3 information windows 4 LCD display 5 balance keyboard 6 rotary legs 7 level 8 Pan cover (complex) 9 keyboard cover 6 4 7 3

Connections views: ~230V Feeder Feeder RS232C RxD (receiver) xd (transmitter) masa 1 2 3 4 5 6 7 8 9 4

6. Keys and indicators Max d = Keys functions description: key I/ - switch-on/switch-off (standby), key - numeric key / menu, key - tare (subtract package weight from weighed mass) key - numeric key / data output (print / transmission), key 0 - numeric key / zeroing (balances for direct sale use only), indicator - result stabilisation, bar indicator - load indicator 0 100%, indicator OFF - stand-by mode, Max, d - metrological parameters Additional functions of keys: 0 - Next digit, - Decimal point, - - Next position, end. 7. Workplace preparation for balance Balance workplace should be choice carefully in order to reduce influence of factors, that could disturb balance operation. he workplace should assure appropriate work temperature of balance and necessary space for normal balance operation. he balance should stand on stable table that is made of material non affecting magnetic on balance. Sudden motion of air, vibration, dustiness, violent changes of temperature and humidity above 90% are forbidden. he balance should stay away from heat sources and devices that emit strong electromagnetic radiation and magnetic field. 5

+33 C +18 C 8. Balance preparation for work 9 1 2 1. Remove balance and power supply unit from the package. 11 8 2. Place the balance on stable foundation, in place not subjected to mechanical vibrations and air movements. 12 10 5 3. Unscrew protection rod 10 and take it out with protection cap 11 (if it appears in scale). Into the same place push decorating button 12. 4. Adjust the balance level, using the rotary legs, so the air bubble in the level 7 located in rear part of balance, takes the central position. 6 4 7 5. Connect together walls edges of pan cover 8. 6. Put pan cover on balance and cover the lid 9. 6

Attention: Pos. 10 and 11 are optional. If balance was moved from environment with lower temperature to the room with higher temperature, condensate can be formed on the surface of balance. In this situation it is forbidden to turn balance on, because balance can be damaged. Before turning on balance, it should stay in a new environment for 4 hours in order to acclimatization. 9. General principles regarding balance operation 1. During balance operation, in order to confirm its efficiency, it is recommended to check the weighing precision by putting a object of exactly known weight before and after series of measurements. In case of allowable measurement error exceeding it is recommend to make calibration by standard weight or contact authorized Service Company to perform balance adjustment. 2. Weighed mass should be placed in the pan centre. 3. he balance enables tare setting in the whole measuring range. It is performed by pressing " " key. are setting does not widen measurement range. It only subtracts tare weight from the mass, currently placed on the balance. o facilitate the mass control on the pan, and avoid the range exceeding, the balances have the load indicator, scaled in 0 100%. 4. he weighing result should be read during the " " indicator lighting, which indicates the result stabilization. 5. When there is no weighing, but the balance should be ready for operation, it may be switched off by I/ key. It turns balance reading system off and entering into the standby mode that is indicated by OFF. Balance turning on is performed by pressing " I/ " key. 6. In balances with active 0 key (zeroing) before putting weighed mass on the balance, make sure, if zeroing indicator 0 is displayed if the zero indication is not shown, press 0 key and wait for balance zeroing and zero indicator appears. Only then you can put an object on the balance. 7. Balance mechanism is very precision device and sensitive to overload, shocks and impacts. Do not overload the balance over 20% of maximum load. Niedopuszczalne jest naciskanie szalki ręką. Make sure, that pan is secured against accidental stress on the period of transport. 10. Balance operation principles with power supply form accumulator (battery) 1. he balances can be supply from ~230V mains thought power pack delivered with the balance. Moreover accumulators also can be used. hey can be placed in box inside balance. It is possible to use normal batteries. In order to exchange accumulators for batteries it is necessary to turn off charging accumulators, by battery function (bat OFF option ) that is descrapt in the further manual part. 2. o extant work time of accumulators (battery), it is possible to turn off display and next balance automatically. he settings of timer operation is made by b_ligh and Auto OFF functions. 7

3. Charging of accumulators is made automatically, when balance is connected to power supply unit (also during weighing) Charged state of accumulators can be checked by auxiliary function battery (bat VoL option) 11. Accumulators (batteries) exchange 11 1. Remove pan lid that shields scale pan. Remove pan cover and put it near the balance. 2. Remove pan welt. urn around balance and put it on the pan cover. Open cover 11. During turning B200(D) balance around, assure that balance weight does not lean against the pan. Out of control stress puts on pan could damage mechanical balance 13 3. Remove accumulator box 12 and then put accumulators type AAA inward it. 12 he arrangement method of accumulators in the box. 8

12. Start-up Leave the pan empty, plug the feeder to the mains (~230V/50Hz) and plug the feeder connector to the 12V power socket at the back of the scale he scale proceeds with following start-up actions: C-1 Basic electronic components tests: C1, C-2,... C-6. C-5 bt... Program version. ------- Zeroing. Ready. 13. Connecting the balance to a computer or a printer Balance may send data to the computer or printer through RS232C port. During the operation with computer the balance sends the weighing result after the initiating signal from the computer, or pressing key. o cooperate with balance, the computer must have the program, enabling the balance data receiving and processing. AXIS company offers computer programs for cooperation with balances, available on web pages www.axis.pl : - est RS232C - program for testing balance serial port (full version), - ProCell program allowing for balance cooperation with Excel spreadsheet and other Windows applications (demo version). 9

Standard transmission parameters: 8bits, 1stop, no parity, 4800bps. o change transmission parameters use "rs-232" function (see further part of the manual). Data transmission protocol description (Long protocol) Computer Balance: initialising signal S I CR LF (53h 49h 0Dh 0Ah) Balance Computer: balance indication in the following format (16Bytes) Byte 1 - sign or space Byte 2, 11 and 14 - space Byte 3 4 - digit or space Byte 5 9 - digit, decimal point or space Byte 10 - digit Byte 12 - k, l, c, p or space Byte 13 - g, b, t, c or % Byte 15 - CR (0Dh) Byte 16 - LF (0Ah) Connection cable WK-1 (balance computer / 9-pin): BALANS COMPUER Connection cable WD-1 (balance - KAFKA printer): BALANCE PRINER KAFKA printer internal switches set-up: SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 on off on off off on off off 10

14. Basic balance functions In further part of this manual the following graphical symbols will be used for balance functions description. - put load on the pan 12g - put load of the pan - press a key during indication - forced change - automatic change 14.1 Normal weighing 0.00 g When the pan is empty and indication is different than zero press key. 43.04 g Weighing result should be read when the indicator " " lights. 14.2 Weighing with tare 23.13 g 0.00 g he balance is equipped with tare equal to its range. otal amount of tare and net mass can not be exceeded max. Balance range. 63.24 g 11

15. Balance special functions All balances, besides the basic metrological functions: weighing and tare setting, have a set of balance special functions. Basic set of includes the following special functions: - Automatic zeroing function (AutotAt) - pieces counting (PCS), - Convert mass units (UnIt) - Convert percentage (PErCEnt) - Preparation of recipes (recipe) - Calibration by standard weight / internal calibration option (CALIbr) - setting of work mode for serial port (rs-232) - charging a battery settings (battery), - bright light settings (b-light) - automatic turning off balance (Auto OFF) - weight indication resolution settings (res), - Activation of above-mentioned functions (ACtIV) - Return unit to default settings (default). Other functions may be available as options for demand (description of all special functions is presented in the separate document). After pressing Menu button, start menu will be displayed. he functions are displayed with the successive numbers: F1-PCS, F2-AutotAr, ect. User may change the menu content by activating or deactivating the available special functions with the Menu update function (ACt). During the special functions switching the display shows the MODE indicator. 15.1 Autozeroing (AutotAr) 0.01g AUtOtAr When AUtotAr function is activated, a balance automatically keeps zero indication if a pan is empty or if zero indication is acquired by pressing key. o leave the function press key, then with key chose AUtOtAr and AUt off. Note: Autozeroing function is activated automatically for 10 min. after switching-on AUt off AUt on AU 12

15.2 Pieces counting function (PCS) 12.05 g hat function allows for counting the identical details, e.g. tablets or buttons, contained in the weighed batch. he measurement takes place in two phases: 5 0.00 g - first phase calculation of single detail weight upon the basis of sample of specified number of pieces 5, 10, 20, 50, 100, 200, or 500 detils, - second phase counting the details in the weighed batch. 23.04 g PCS PCS o FF PCS on 5 Functions has the following options: - PCS OFF function deactivation, - PCS on start preparation of recipes - PCS... use the last written unitary mass. - PCS 5, 10, 20, 50, ect number of pieces in a batch - PCS SEt write free number of pices in a batch - PCS MJ direct write a unitary mass - out exit without saving Notes: 1. It is recommended, that the single detail weight is higher than the balance reading graduation, and the weight of sample, used in the first phase is higher than 100 of reading graduations. 2. Err-PCS massage indicates that pan is empty or when the single detail weight is lower than one reading graduation (user may calculate the pieces, keeping in mind, that it increases the error). 0 pcs 12 12 pcs 13

15.3 Weighing unit selection (UnIt) 1.60g UnIt CArAt 8.00 ct Use this function to choose weighing unit: - CarAt (1 ct= 0,2 g), - MGrAM (1mg=0,001g), - KGrAM (1kg=1000g), - Pound (1 lb=453,592374g), - Ounce (1oz=28,349523g), - OunCEt (1ozt=31,1034763g), - GrAIn (1gr=0,06479891g) - PennYW (1dwt=1,55517384g), - Gram (1g). he example at the left presents how to set carats as weighing unit. 15.4 Percentage weighing (PErCEnt) 100% 0.00 g his function enables to display weighing result as a percentage of a reference sample. A measurement is performed in two phases: - first phase weighing a reference sample, 19.07 g PErCEnt PEr off PEr on - second phase measuring specific sample as a percentage of the reference sample. Weighing result is displayed in different format, depending on the reference sample weight value. For values of 0 3,5% of weighing range the format is 100.0, for values 3,5 35% it is 100.00 and 35 100% - 100.00 he function has the following options: - PEr off disables the function, - PEr on stores current indication as 100% and activates percentage weighing, - out exit without change. 50% 100.00% Note: When the function is activated key function does not change. 50.00% 14

15.5 Weigh summing (recipe) 0.00 g recipe rec off his function enables to weigh few ingredients in one container and to display aggregated sum of all ingredients. he function has the following options: -rec off leave the function and display aggregated sum of all ingredients, -rec on activate the function, -rec Con - return to previous series of weighing, - out exit without change. A rec on Before weighing each ingredient (A, B, C, etc.) remember to tare the balance. B o o 10.01g o read aggregated sum of all previously weighed components use key, recipe and rec off option. C o o 10.02g Note: When recipe function is active, the sign o is displayed at the left of the display. When rec off option was used, SUM indicator disappears after pressing key. o 10.03g recipe A+ B+ C rec off 30.06g 15

15.6 Calibration with external weight (CALIb) Calibration with external weight standard in verified balances should be performed in case balance indications exceed permissible error. o calibrate the balance a service centre should use calibration weight as stated in echnical Data table (or of better accuracy). Operations sequence: CALIbr CAL off... CAL on - CAL - Klawiszem wywołać pojawiające się kolejno funkcje użytkownika. Press key to call functions menu and to choose CALIbr with key. Calibration function options: - CAL off turn autocalibration off - CAL on start calibration with external weight - out exit without saving Press press to choose CAL on. Wait until zeroing is finished. When LOAD communicate put a calibration weight on the pan. Wait until calibration process is finished and zero indicated. m LOAD m 16

15.7 Serial port setting (rs-232) rs-232 baud -4800-9600 baud... out he function enables to set the following transmission parameters: - baud (4800, 9600,..., 115200) - transmission speed, - bits (7, 8) - the number of bits in a byte, - PArItY (0, 1) - parity control, - Odd (0, 1) parity control way, - SendInG - transmission type of result by serial port - Stb transmission after used of button and stabilization of result, - Stb transmission after used of button without result stabilization, Stb automatic transmission after putting load and result stabilization, - Cont. continuous transmission approx. 10 results per second. Default parameters are underlined. In order to set the required parameters activate rs-232 function, select the proper parameter and press key during displaying of required parameter or option value. On the adjacent diagram setting of transmission rate of 9600 bps is shown. Setting of others parameters is analogous. After setting of appropriate parameters and options exit by selecting out. 15.8 Charging a battery settings function (battery), battery bat OFF bat on battery function enables to turn on or off charging a batteries and check charging state during working with power supply unit Functions has the following options: - bat OFF charging accumulators is turned off (this option is necessary in case of using non-rechargeable batteries - bat on charging accumulators is tunr off. Accumulators are charging after turning off balance by I/ key, - bat VoL readout of charging accumulators state in % (return to readout of mass by press key) - out Exit without saving 17

Charging non-rechargeable batteries to test can cause damage of balance. 15.9 Display setting function (b_light) b_light b_l on he function is used to choose action method of display bright light - b_l OFF bright light function deactivation, - b_l on bright light function activation, - b_l ECO turn this function after 30 seconds of inactiving - b_l bat the same as above but only during supply from accumulators. - out Exit without saving urning bright light function off reduces energy consumption that is essential with power supply from accumulators. 15.10 Automatic turning off balance (Auto OFF) Auto OFF AOF on he function turns balance off automatically without any balance activity. It reduces energy consumption and extend working time of balance with power supply from accumulators: - AOF OFF balance will not turn off automatically - AOF on turn balance off after 5 minutes of inactiving - AOF bat the same as above but only during supply from accumulators. - out Exit without saving 5min. OFF 18

15.11 Reading unit choosing (resolut) resolut his function enables to choose reading unit value (resolution). he function is only available in B200 and B2000. Available reading units: - wagi B200: d=0,01g i d=0,001g, - wagi B2000: d=0,1g i d=0,01g. 0.000g 15.12 Function Menu customisation (ACtIV i default) 0.00 ACtIV AUtOtAr rs232 his function enables to select special functions that will be displayed after pressing key. Easy access to the most useful functions will shorten operation time and make work more comfortable. o differ ActIV function from the function menu, indicator is displayed at the left side of the display. It is possible to return to default setting by special function default Operation sequence shown on the picture, presents how to add RS232C parameters setting function (rs-232) to the function menu. o remove a function from the Function Menu choose rs off in the last operation. rs off rs on 19

16. Maintenance and repairs of small defects 1. he balance should be kept clean. 2. ake care that no dirt gets between the casing and the pan. If found any, remove the pan (lift it up), remove dirt and then replace the pan. 3. In case of improper operation caused by short-lasting power supply decay, unplug the balance from the mains and then plug it again after few seconds. 4. o calibrate the balance contact nearest service. 5. It is forbidden to make any repairs by unauthorised persons. 6. o repair the balance, please contact our nearest service. Error communicates: Communicate Possible cause Remedy C-1...6 (over 1 min.) balance doesn t work selftests failed protection rod if displayed more than 1 minute, contact an authorised service remove protection rod and cap L pan missing put the pan on mechanical damage contact an authorised service H overloading remove the load from the pan indicator does not appear mechanical damage unstable ground vibrations air flows balance damage contact an authorised service place the balance on a stable ground not affected by mechanical vibrations and airflows contact an authorised service - - - - - - taring in progress as above 20

Declaration of Conformity info@tursdaletechnicalservices.co.uk We: AXIS Spółka z o.o. 80-125 Gdańsk, ul. Kartuska 375B confirm with all responsibility that B series balances: B200, B200D, B2000 i B2000D marked with CE mark comply the following: 1. EN 55022 standard Limits and methods of measurement of radio disturbance characteristics of information technology equipment and IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3: esting and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test, harmonised with the Council Directive 89/336/EEC. Additional information - Conformity evaluation for the Council Directive 89/336/EEC were carried out by Laboratorium Badawcze Oddziału Instytutu Elektrotechniki w Gdańsku. Gdańsk, 23.09.2008 r. Per pro Director of AXIS Ltd: Production Manager Jan Kończak Signature In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOE: "his instrument doesn t have AEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)." 21