Dimmer / 2-Way Dimmer

Similar documents
2-Way Dimmer (1 Gang)

2-Way Dimmer (1 Gang)

Dimmer Switch (1 Gang)

Plug-in Dimmer Socket Kit

Plug-in On/Off Socket Kit

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Dimmer Switches (Modular)

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

Dimmer Switches (Modular)

Dimmer Switches. Product Range. Dimmer Switches For Tungsten, Halogen & Low Voltage. Facsimile: Website:

Installation Instructions

Installation Instructions

2 PORT MOTORISED VALVE (28 mm)

Wireless Dimmer Installation and User Guide

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

3 PORT MOTORISED VALVE (22 mm)

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Installation Instructions

PRODUCT MANUAL Desktop LED Dimmer and Receiver

PRODUCT MANUAL Onyx 2 Zone In-Wall Wireless LED Dimmer and Receiver

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

3 PORT MOTORISED VALVE (32/38 mm)

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

GL1200T Cut & Seal. (GL1200 Seal only)

Installation Instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

c-go 24V/6A 24V/8A 24V/12A

Frequently Asked Questions

HomeWorks QS Designer RF Maestro Local Controls

Installation Guide Rollerdor RD55 Econ Roller Garage Door

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

2 PORT MOTORISED VALVE (22 mm)

USER S MANUAL. Installation, Operation, & Maintenance

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SUBMERSIBLE WATER PUMP

HomeWorks QS RF C L Hybrid seetouch Keypads

PIL0478 ISSUE 01/ 07/16

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Installation & User Instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

Elegance Electrician s Installation Guide

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

FAQs. General LED Retrofit P.1. Product features LED Retrofit P.2. Installation LED retrofit. General CANbus P.5. Product feature CANbus P.

GETTING STARTED WITH IN-WALL DIMMER SWITCH

RadioRA 2 Maestro Local Controls

The Standard for Incandescent Replacement ISSUE 3

SKC400U SLIDING GATE OPENER OWNER S MANUAL

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

User Guide for Viridian EV Charging Stations

EC200 ELECTRONIC CONTROL SYSTEM

Operating Instructions. Tronic Dimmer

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Wireless Radiator Valve

Primary controls RadioRA 2 designer dimmers and switches

Compact System NRGS 11-2 NRGS Original Installation Instructions English

1 Safety instructions

SUBMERSIBLE WATER PUMP

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

DC POWER SUPPLY ALIMENTATION C.C.

Modern Soft Edged White Moulded Wiring Accessories

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

INSTALLATION. **Microprocessor Status LED:

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Zone 1 Linear Range - Installation Guide

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

IQL Helios Area-/Streetlight. User Manual

PRODUCT MANUAL Gecko Wireless 2 Zone LED Dimmer and Receiver

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

RadioRA 2 Maestro Local Controls

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

Wired Maestro Local Controls

EC225 Power Control System

Installation Guide and User s Manual

Declaration of Conformity

LED NEON FLEX INSTALLATI ON GUI DE

pond and garden 3 x 1 watt / 5 x 1 watt

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

INSTALLATION & MAINTENANCE MANUAL HBL

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Lighting GENERAL INFORMATION. Daytime running lamps. Condensation. Stop lamps. Halogen headlamps. Reversing lamps. Bi-Xenon headlamps

Serena Remote Controlled Shades

Color Changing Pool Lamp

DUALBRITE Motion Sensing Coach Light

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Installation Manual. CS9300 Professional Series Landscape Lighting System

Maestro Wireless Dimmers and Switches

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

IGLOO IGLOO EASY INSTRUCTION MANUAL

DALI 650mA LED Driver

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

Transcription:

Dimmer / 2-Way Dimmer Model No. JSJSLW455 Instruction Manual Connect Series www.lightwaverf.house Version 2

EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham Faraday Wharf Holt Street Birmingham B7 4BB Tel: +44 (0)121 250 3625 Email: enquiries@lightwaverf.com Model Number(s): Description: Directives this equipment Complies with: JSJSLW455 2-Way Dimmer (Dimmer/2-Way) 2006/95/EC The Low Voltage Directive N/A 2004/108/EEC The Electromagnetic Compatibility Directive 1999/5/EC R&TTE Directive 93/68/EEC CE Marking Directive Standards Applied in order to verify compliance Safety: BS EN 60730-1: 2011 Health: R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08) EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007 EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08), EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A, EN 61000-3-3: 2008, EN61000-4-2: 2009, EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012, EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004 For and on behalf of LightwaveRF PLC ---------------------------------------- Name J Shermer Position Managing Director

Get Started How do I get started? Please refer to the following installation and setup instructions. This will guide you, step by step, through the installation and setup process. What do I need? To install the dimmer, you will need to remove and replace the existing lightswitch. This is usually straightforward, but you must ensure that there is a suitably deep housing (backbox) and understand how to safely turn off the electricity supply. You will also need suitable electrical screwdrivers. Help video & further guidance For additional guidance, and to watch a video that will help guide you through the installation process, please visit the support section on www.lightwaverf.house

Overview Installation Amber LED. When illuminated, the dimmer is off. On button. Hold to raise light level. Off button. Hold to lower light level. Blue LED. When illuminated, the dimmer is on. IMPORTANT: All LightwaveRF products can be legally DIY installed in your own home; however, if in doubt, always consult a qualified electrician or heating engineer. It is important to install this product in accordance with the following instructions. Failure to do so may void your warranty.

Installation Live in Switched live (live out) Screw mounting hole 2-Way switching connection IMPORTANT: If conducting an insulation resistance test, all LightwaveRF products must be disconnected from the mains, or damage will occur.

Quick Start Guide Installation Understanding the different dimmer gangs This dimmer comprises 2 gangs: one is a standard LightwaveRF Dimmer module and is labelled Master ; the other is a 2-Way LightwaveRF Dimmer module and is labelled Slave. The standard gang can be wired as a standalone dimmer OR be connected to other LightwaveRF 2-Way Dimmers to perform 2-Way switching. The wiring diagram on the following pages illustrates how this gang should be wired. The 2-Way gang must be connected to another standard LightwaveRF Dimmer Switch in order for it to function properly. The second wiring diagram on the following pages illustrates how this gang should be wired in conjunction with another LightwaveRF Dimmer.

Quick Start Guide Installation VERY IMPORTANT A LightwaveRF 2-Way Dimmer needs to be used in conjunction with a standard LightwaveRF dimmer to perform 2-Way Switching. The LightwaveRF 2-Way Dimmer cannot be used in conjunction with a standard lightswitch. This will cause damage to the dimmer. Never install and run power to a 2-Way dimmer before first installing and connecting the corresponding standard LightwaveRF dimmer. Serious damage could be caused to the unit. The 2-Way Dimmers use standard 3-core connecting cables; however, because they are electronic dimmers, they utilise one of the cores as a signal cable ( S ) running between the dimmers (as shown on the diagram). This is low voltage only and should not be connected to 230V mains; serious damage will occur. Up to six 2-Way dimmers (six gangs) can be connected to a standard LightwaveRF dimmer switch. Each 2-Way can be connected directly to the standard dimmer, or connected to each other in a daisy-chain. This provides an alternative to using intermediate switches (maximum cable length of 100m).

Installation 1. IMPORTANT: Turn off the mains electrical supply. 2. Ensure that the wall (back) box has a minimum depth of 35mm. 3. Remove and disconnect the existing lightswitch (if applicable). It may be useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new dimmer. Some existing wiring configurations can be complex so take care. 4. Gently remove the dimmer faceplate by inserting a screwdriver into one of the bottom slots and lifting away from the unit as shown.

Installation 5. Connect the wiring as per the wiring diagram on the following page. Ensure that the terminals are properly tightened and that no bare wire is visible. Be aware that existing wiring circuits are not always correctly coloured, and that there may be other wired connections present in the back box; if in doubt, always seek the advice of a qualified electrician. NOTE: LightwaveRF dimmers do NOT require a mains neutral wire to be connected; they only require live in and switched live out. 6. Any earth wires present must be attached either to the earth terminal located in the back box or capped with a strip connector. The dimmers are double insulated so are not required to be earthed directly. 7. Screw the dimmer switch to the mounting box and ensure that the screws are sufficiently tight to support the product, but do not over tighten as this may cause the chassis to bend. Ensure that the plastic spacer is correctly aligned and that no wires are trapped between the dimmer switch and the back box.

Installation (Standard Dimmer Gang) The switched live may be marked by brown/red tape to emphasise that it is not a neutral wire. NOTE: Wiring shown for one of two gangs. Please repeat for other gang. Live wire In. This should be brown or red in colour. Switched live wire out. This should be blue or black in colour. Signal cable connection for use with LightwaveRF 2-Way Dimmer only (LOW VOLTAGE: Do not connect to live mains!) Earth wire connects to terminal in back box (can be capped off instead if no terminal present)

Installation (2-Way Dimmer Gang) Switched live Earth From lighting circuit Live 3-Core cable IMPORTANT: The signal cable input marked S must ONLY be connected to the wire running to the other dimmer NOT live mains; this will cause irreparable damage. Live Signal cable Switched Live Standard Dimmer 2-Way Dimmer

Installation 8. Replace the plate a click sound should be heard to signify that the plate has been correctly replaced. Important things to consider Wattage ratings for the Dimmers are per gang. The maximum circuit load for each 2-Way Dimmer Gang is equal to the maximum load on the standard LightwaveRF Dimmer it is connected to (i.e. 250W or 210W). ONLY Dimmable lamps can be used even if the Dimmers are used solely to switch between the on and off states without dimming. This is because the technology used in an electronic dimmer is fundamentally different to that of a simple on/off switch and requires compatible lamp technology. NOTE: Compatibility between electronic Dimmers and LEDs can be affected if the total circuit loading is very small. Total LED load decreases (relatively) as it is shared between a greater number of connected Dimmers; therefore, as more 2-Way Dimmers (up to 6) are added to a single circuit, it is possible that LED performance may become less stable.

Compatibility & Lamps Compatibility Ensuring the compatibility of your lamps (bulbs) with LightwaveRF Dimmers will ensure that you get the best experience from your lighting setup. LightwaveRF dimmers are compatible with the following: Selected dimmable LED lamps (see www.lightwaverf.house for further guidance and information). Standard mains voltage incandescent & low energy incandescent lighting (min 20W, max 250W) GU10 and equivalent HI spot mains halogen lamps Dimmable electronic low voltage transformers (20W - 250W max.) Inductive transformers (40 170VA max.) LightwaveRF dimmers are NOT compatible with the following: Wirewound transformers (generally older style) Electric motors Non dimmable LEDs CFLs CFL tube arrays

Manual Operation Manual operation Manual dimming Tap the on (top) button once to switch the dimmer on (blue LED indicator will illuminate). Press and hold the on button to raise the light level. Tap the off (bottom) button once to switch the dimmer off (amber LED indicator will illuminate). Press and hold to lower the light level. NOTE: When the on button is tapped to turn on the dimmer, the light level will return to that at which it was last at before the dimmer was turned off. The on or off buttons can then be pressed and held to customise the light level.

Troubleshooting Problem: The 2-Way Dimmer will not operate the lights and the LEDs on the Dimmer do not light up. Solution: Firstly, check that there is power to the dimmer. Make sure that the connected lamps (bulbs) are functioning correctly; the dimmer switch will not run unless it has a functioning lamp/s to complete the circuit. Ensure that the maximum LED/incandescent loading has not been exceeded (if so this may have damaged the dimmer). Check that the wiring is correct; it is important that the live, switched live and signal wires are attached to the correct terminals; a common mistake is to reverse the live and switched live connections. Remember, the signal terminal must NOT be connected to 230V mains. If these measures fail, contact technical support via www.lightwaverf.com. Problem: The 2-Way Dimmer has power (LEDs on) but will not turn on the Lights/turns on then off by itself/ will not operate from the other dimmer. Solution: Check that the wiring is correct; it is important that the live, switched live and signal wires are attached to the correct terminals; a common mistake is to reverse the live and switch live connections which may cause the 2-Way Dimmer to function improperly. Remember, the signal terminal must NOT be connected to 230V mains. If these measures fail, contact technical support via www.lightwaverf.com.

Troubleshooting Problem: The LED/CFL lamps that I am using flash / do not dim properly. Solution: Ensure that the lamps being used are dimmable; non dimmable lamps are not compatible with LightwaveRF dimmers. If the problem persists, the LED/CFL lamps may not be compatible with the dimmers; please contact technical help (via www.lightwaverf.com) for further advice. Problem: The 2-Way Dimmer will not link to a LightwaveRF controller. Solution: The 2-Way Dimmer is not designed to link to a LightwaveRF controller and therefore does not contain an RF radio module. This is because it takes direct commands, instead, from the corresponding standard LightwaveRF dimmer via the connected signal wire. The standard LightwaveRF dimmer can be linked to a controller and passes on commands to the 2-Way Dimmer automatically. Problem: The dimmer keeps turning off automatically / will not turn off. Solution: The connected standard LightwaveRF dimmer may be locked. This may have been done using a Socket Locker or from the LightwaveRF App. If it is locked on, then the 2-Way Dimmer will not turn off manually. If it is locked off, it will be possible to turn the dimmer on, but it will automatically turn off again after five minutes. To unlock the dimmer, press the unlock button on the Socket Locker or Smartphone App. If this is not possible, the dimmers can be reset by turning of mains power to the circuit for a period of 30 seconds.

FAQs Q. Can I link the 2-Way Dimmer to a LightwaveRF controller? A. No. The 2-Way Dimmer is designed to take wired commands directly from the standard Dimmer that it is connected to. It does not contain an RF module and will not enter linking mode. Q. How do I know that the dimmer switch will fit? A. The Dimmer is the same size as a standard lightswitch - it will fit all back boxes (standard lightswitch housing) over 35mm deep. Q. Is it legal for me to install the dimmer? A. Yes, LightwaveRF is fully legal for you to install in your own home. Q. Is there a maximum number of lamps I can control with the dimmer? A. You can control any number of lamps (bulbs) as long as they do not exceed the maximum loading in total. Note: Max. load differs for LED/incandescent. Q. How many devices can I have on the LightwaveRF system? A. Each device has 6 memory slots for up 6 controllers (one of these can be the Lightwave Link allowing up to 6 smartphones to control hundreds of devices. Q. Can I use LED or CFL lamps? A. Most LEDs can be controlled as long as the lamps are dimmable variants (see www.lightwaverf.com for guidance). CFLs are not compatible.

FAQs Q. Can I use non dimmable lamps (bulbs) if I don t dim them? A. No. The lamps must be dimmable even if they are not dimmed; the technology in the lamp must be compatible with that of the dimmer. Q. What if I need a switch to operate on/off only? A. A LightwaveRF Relay in conjunction with a Wire-free Switch can be used for on/off switching in place of the dimmer (see www.lightwaverf.com). Q. Can I separate and change individual switches in multigang Dimmers? A. Multigang dimmers are not designed to have their switch modules separated and interchanged; disconnecting and removing Dimmer Modules will invalidate the warranty. Q. What Happens after a power cut? A. Standard LightwaveRF dimmers default to the off position after a power cut. The 2-Way Dimmer will, therefore, also default to off. This can be overridden using the Lightwave Link to set default status for devices on power up. See www.lightwaverf.com for details. Q. Is it normal for the dimmer to get warm when it is turned on? A. Yes it is perfectly normal for dimmer switches to feel warm to the touch if left on for a period of time close to maximum load. It is completely safe.

Technical Specification Specification Standard Gang: RF frequency: 433.92 MHz Input rating: 220-240V~ 50Hz. Output rating: 3W~250W max Incandescent Load: 20W min 250W max 2-Way Gang: Input rating: 220-240V~ 50Hz. Back Box Depth: 35mm min. Earthing Requirement: Not essential (double insulated) Standby Energy Use: Less than 1W (per gang) Wiring: Neutral wire NOT required Warranty: 2 year standard warranty

Version 2 2 Quadrant Park Mundells Welwyn Garden City Herts AL7 1FS 01707 386035 www.lightwaverf.house