Hya$sville Volunteer Fire Department Training. Elevator Rescue Module

Similar documents
Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

Facilities Management

Placement on the fireground simply refers to how and where an apparatus is placed at the scene.

ATD-7331A 3-Ton Hydraulic Service Jack

Developed by Engineer Bobby Bartlett February 2012

RAPID INTERVENTION TEAM STANDARD OPERATING PROCEDURES

STANDARD OPERATING GUIDELINES

Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 3: Gearless Drive Systems

ELEVATOR S GENERAL FUNCTIONS GUIDE

BIG SPRING FIRE DEPARTMENT STANDARD OPERATING PROCEDURES SOG 417: LADDER TRUCK OPERATIONS SOP: 417. Ladder Truck Operations.

DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control

TRAXALL. INSTALLATION and USER GUIDE for CD52 Bandit (CSA UL Cer fica on) LineStat

GRANDVIEW TOWNSHIP FIRE DEPARTMENT STANDARD OPERATING GUIDELINES. #333 Vehicle Fire Date Issued: 01/01/2014 Date Last Revised: 01/01/2014

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

Presenter s Notes SLIDE 1

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

T ASK S KILL DESCRIPTION AND DETAIL

WORKERS COMPENSATION (OCCUPATIONAL HEALTH AND SAFETY) AMENDMENT ACT, 1998

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

Welcome to the Dover Fire Department Brian F. Bashista, Fire Chief

INSTALLATION INSTRUCTIONS

ALL TERRAIN CRANE AR-1600M

AERIAL NEEDS ASSESSMENT FOR THE SOUTH SALEM FIRE DISTRICT

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

PAC S MISSION. PAC Has Been An Industry Leader For Mounting Tools And Equipment For The Fire & Rescue Industry.

In the November 2006 issue of FireRescue, ( Easy

TRAINING AND EQUIPMENT MANUAL 304 LADDER PRACTICES GROUND LADDERS EFFECTIVE: OCTOBER 2007

DC Series Installation Manual (# )

Southern California Edison (SCE) PRP Solar Si?ng Survey Overview

Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)

29CFR 1910 Subpart D Walking-Working Surfaces Ladders

Constant Running Hydraulic Pump Installation Guide. Document Number: Date: March 2006

Fraco SEH Series consists of construction hoists designed for personnel and material transportation. The SEH Series offers different car sizes.

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

FIRE ATTACK STRATEGIES

Vehicles shall be operated in compliance with all traffic laws of the State of Ohio, including those Sections pertaining to emergency vehicles.

Mobile endless winch up to 300 kg! New! Hoisting Equipment Endless winches. Endless winch, mobile model YaleMtrac. Capacity kg.

T6 Owners Manual. Basic Function

MAINTENANCE EVALUATION CHECKLIST ELECTRIC ELEVATORS

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

Operator s Manual. 2010, 2015, 2020, 2025 Material Lifts

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities - Controlling Revised

ATLAS 2000 SINGLE LINE HYDRAULIC HOIST

ESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY AND HEALTH STANDARD STANDARDS

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Humma UV35-25 LOAD CHARTS. Revision 9. A division of Westfield Nominees. Contains the following load charts: Main winch (Standard & Stationary)

ELECTRICAL SAFET Y FOR CONTRACTORS

Installation Instructions Table of Contents

2000 lb WINCH. Instruction and Operation Manual

0 Does this topic relate to the work the crew is doing? lf not, choose another topic.

Preventive Maintenance for Pail Melters

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

MODEL : TM-1882 CRANE SPECIFICATIONS. MAXIMUM LIFTING CAPACITY lines)

HYDRAULIC TRUCK CRANE GT-600EX CARRIER : TC section, 11.0 m 43.0 m DIMENSION Overall length. approx. 13,170 mm Overall width

Position Number Community Division/Region Yellowknife North Slave

Description. Construction Method Tubular Extruded Aluminum. Body Material Options SST / Aluminum Aluminum

TADANO MODEL TM TON CAPACITY

2 Elevators Distributed Embedded Systems Philip Koopman September 2, 2015

Major Code changes MESA Continuing Education

Jazzy 1122 Wheelchair Trainer: Owner s Manual

Driving Fire Apparatus Safely

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

Bulloch County Fire Department Bulloch County, Georgia. Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report

INSTRUCTION MANUAL 16K - Fifth Wheel Hitch

Plug-in Dimmer Socket Kit

Product Line Glossary Terms

UNIVERSITY OF HONG KONG Department of Electrical & Electronic Engineering M.Sc.(Eng) in Building Services MEBS Utilities Services

First Responder Beware

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

NOTES ON ELEVATOR SYSTEMS

Large Tank Fire. Thailand December 1999

12 Electricity and Circuits

SAFETY AND HYGIENE REGULATIONS DESCRIPTION OF A FORKLIFT TRUCK GENERAL RECOMMENDATIONS

The Navigator Elevator Landing System. Installation Manual. System Components: Selector Operation. Digital Connection

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

Minimum required on Engine Co. Attic ladder Roof ladder with hooks Extension ladder


Hollister-Whitney Elevator Corporation

INSTRUCTION MANUAL 16K - Fifth Wheel Hitch

Heavy Equipment & Rigging Specialist Training

EPA-EPC-EPF. Wire rope snatch blocks for material handling and man riding

Apparatus Riding Assignments

Every moment of your response has its own unique demands and so should your fire apparatus. AERIALS

ALL TERRAIN CRANE GA-1500N

Chapter 42. Objectives. Objectives 01/09/2013. Gaining Access and Patient Extrication

Hya$sville Volunteer Fire Department Training. Chainsaw Maintenance

YORK COUNTY FIRE TRAINING EMERGENCY VEHICLE DRIVER REFRESHER

HERCULES SIGN POST DIGGER DERRICK

A X, Safety Code for Elevators and Escalators

New Elevator Technologies To Generate, save, and store electricity

CHICAGO COMMITTEE ON HIGH RISE BUILDINGS

Whiting Equipment Canada Inc. Car Progression Systems

OPERATOR S MANUAL 2200 SERIES LIFT - LIL HOISTER. July 2017

INSTALLATION M ANUAL

XL3100. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed.

Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

Transcription:

Hya$sville Volunteer Fire Department Training

Elevator Types Cable Elevators Hydraulic Elevators Drum Type Trac9on Type

Cable Elevator A typical cable elevator consists of an elevator shac for the car to travel within, an elevator car, cables afached to the car, counterweights, ver9cal tracks, emergency safety brakes, and an equipment room for the electrical equipment (electric motor and winding drum) to raise or lower the elevator. Cable elevators are drum type or trac9on type.

Cable Elevator (contd.)

Hydraulic Elevators Similar in general design to the cable elevator, hydraulic elevators use hydraulic power instead of cables and trac9on sheaves and are generally limited to six story buildings. Newer installa9ons use oil pressure to power a ram. Some less modern hydraulic elevators and hydraulic elevators that travel over six stories may use cables and counterweights. The equipment rooms for hydraulic elevators are normally located at the lower level of a building, but can be at any floor level or 50 to 100 feet away from the elevator shac. The equipment room contains the following main components: Controller or relay panel Hydraulic power unit (The hydraulic power unit consists of a reservoir for the oil supply, hydraulic pump, and valves to raise or lower the elevator car)

Hydraulic Elevators (contd.)

Drum Elevator A winding drum type elevator consists of a car afached to one or more cables that pass around a winding drum and to a moving counterweight. Counterweight cables are on one side of the drum and car cables are on the other side of the drum. The drum is grooved for cable movement. Both sets of cables run in the same grooves (counterweight cables unwind when car cables wind and vice versa). The equipment room for drum type may be located in a basement or on the roof of a building. Limita9ons in the length and diameter of the winding drum restricts this type of elevator to 150 foot lics and slow speeds. Equipment for this applica9on requires more space than other types of elevators. For this reason, it is no longer manufactured.

Trac?on Elevator Trac9on type elevators are used for higher lics and greater speeds than drum type elevators and use a trac9on sheave instead of a winding drum. In trac9on type elevators, cables are afached to the car and pass over a trac9on sheave to counterweights. In this configura9on, cables passing over the trac9on sheave unwind as fast as they wind and car speed is dependent on the size of the trac9on sheave and the electric motor speed. There are two types of trac9on equipment: High speed direct trac9on or gearless type trac9on consists of a slow speed DC motor directly coupled to a trac9on sheave with a brake wheel mounted on the motor shac. Geared trac9on type uses a high speed motor. The motor is geared to a trac9on sheave through worm gears with a brake wheel between the worm gears and motor. Since there is less weight and equipment with trac9on type elevators, the equipment room is usually located on the roof or above an elevator shac in high rise buildings.

Elevator Rescue Prior to ini9a9ng elevator rescue procedures, dispatch and on scene informa9on should be carefully evaluated. When an alarm is received, knowledge of the type and height of occupancies in the geographical area of dispatch will indicate the probable type of elevator (hydraulic or cable), applica9ons (industrial commercial, apartments, mul9 story office buildings, high rise, etc.), and the 9me of day (indicator of the poten9al of trapped vic9ms).

Elevator Rescue (contd.) On scene informa9on should consist of the following minimum considera9ons: Is there an inopera9ve elevator Does the inopera9ve elevator contain trapped occupants and what is the condi9on of the occupant? Has an elevator repair person been no9fied, and if so, what is their es9mated 9me of arrival? What is the loca9on of the inopera9ve elevator? (Between floors or at a landing?) What is the type of elevator? Where is the elevator equipment room? (normally, above for a cable elevator and below for a hydraulic elevator)

Elevator Rescue (contd.) Observe the posi9on of the indicator light at the lobby floor. If phones are usable, have the passenger provide the informa9on from the car panel. In a mul9 car hoist way (shac), ride up in the adjacent car, stopping and looking across the shac as necessary. Fire personnel are never to ride on the top of the car to perform this step. Go to the elevator mechanical room and determine the loca9on of the car by checking the selector equipment, if visible and available. Open the lowest floor door and look up the hoist way.

Elevator Rescue (contd.) Once it has been determined that there is an inopera9ve elevator, personnel with portable radios should be placed: One person in the elevator equipment room to access the main power switches, and or bleed off valve (only for hydraulic). The rest of the crew crew should be on the floor or above the floor of the inoperable elevator where rescue procedures will be taking place. Once communica9on has been established with trapped occupants determine the condi9on of pa9ents, which will help the crew establish a priority for removal of these occupants.

Elevator Rescue (contd.) Personnel in the equipment room should: Check the electrical circuits (main switch, fuses, etc.) to verify if power is on or off to the elevator. Occasionally, circuits are tripped due to overhea9ng and can be safely reset. If there is power to the elevator, turn the power off for at least 30 seconds and then back on again. This can reac9vate the elevator by allowing relays to reset. If the elevator car is within a few inches of the landing, the door may be opened If an elevator is equipped with a recall system, a key can be used to recall the elevator to the ground floor and open its doors, instruct the passengers to push the Door open BuFon (if so equipped). Note: Do not a$empt to rescue trapped passengers from an inopera?ve elevator unless the power to the elevator has been disconnected. This requires that a person be assigned to the main power switch un?l the rescue is completed.

Elevator Rescue (contd.) If the trapped occupants are able to assist have them push the Emergency Stop BuFon. This in return can restart the elevator due to a malfunc9on or overhea9ng of elevator car. (Keep in mind the person at the elevator equipment room can kill the power and turn the power back on to also return the elevator to full func9on). Next instruct the occupants to push the Door open bufon.

Elevator Rescue (contd.) If the elevator car is within a few inches of the landing floor, and the power is off in the equipment room, instruct the passengers to try to manually open the car door. This may require some effort as the car door operates the hoist way door through a clutch mechanism. Moving the car door will release the latch on the hoist way door and allow the door to be opened allowing the occupants to be removed

Elevator Rescue Equipment All firefighters should be wearing or have bunker pants, helmet, gloves, light box, and portable radio. Suggested tools for elevator rescue: Set of Irons Elevator Keys Elevator Poles Adc Ladder