FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum

Similar documents
FLT007A0Z/FLT007A0-SRZ Input Filter Modules 75Vdc Input Voltage Maximum; 7A Output Current Maximum

IND065BLV Hornet: Non-Isolated DC-DC Voltage Regulator Modules

Advance Data Sheet: idq Series Filter Module. idq Series Filter Module 75V Input, 10A Output

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Application Note TES 1 Series

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

S24SP series 40W Single Output DC/DC Converter

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

2W, Low Cost DIP, Dual Output DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

QBVW033A0B Barracuda* Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output

S24SP15004 series 60W Single Output DC/DC Converter

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Advance Data Sheet: Metamere iba Series Non-isolated SMT Power Module PicoBrick

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

MEE1 Series Isolated 1W Single Output DC/DC Converters

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

PG02S Series 2W DC/DC CONVERTER, SIP-Package

NCS12 Series Isolated 12W 4:1 Input Single & Dual Output DC/DC Converters

SELECTION GUIDE. Order code B0303NXT-1W B0305NXT-1W B0309NXT-1W

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Transient Voltage Suppression Diodes SMTO ka > LTKAK6 series. Description. Features. Test Current I T. Reverse Breakdown Voltage (V BR I T

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

SELECTION GUIDE. Order code Voltage(VDC) NTE0303XMC NTE0305XMC

NTA Series Isolated 1W Dual Output SM DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters

Distributed power architectures Telecommunications equipment LAN/WAN applications Data processing Industrial applications

NKE Series. Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES

HP420X. 5A, High Efficiency POL Module GENERAL DESCRIPTION: FEATURES: APPLICATIONS: TYPICAL APPLICATION CIRCUIT & PACKAGE SIZE:

MEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters

DH50 SERIES. DATASHEET Rev. A

Features. V max (Vdc) I max (A) typ. (W) P d

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Surface Mount > 1812L Series. Description. Features. Applications. I max (A) typ. (W) P d. Current (A)

NCS6 Series Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters

Surface Mount > 0603L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W)

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W

Features. Samples. I max (A) P d. typ. (W)

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

High Efficiency POL Module

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Advance Data Sheet: Metamere iac Series Non-isolated SMT Power Module

Delphi Series V48SH, 1/16 th Brick 100W DC/DC Power Modules: 48V in, 1.8V, 30A out

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

POLY-FUSE Resettable PTCs. 2920L Series. Surface Mount > 2920L Series E R RoHS. Description

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

DC/DC Converter URF48_QB-200W(F/H)R3 Series

Silvertel. Ag Features. 2. Description. 57V Boost Converter Module. Small package. Suitable for IEEE802.3af and IEEE802.

SELECTION GUIDE. Nominal Input Voltage. Output Current. Output Voltage. Reflected ripple current

(typ.) (Range) ±18 330# 89 MPW MPW

Delphi Series V48SC, 1/16th Brick 120W DC/DC Power Modules: 48V in, 12V, 10A out

CC06H High I 2 t Chip 0603 size fuses

Surface Mount > 1210L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W) Time (Sec.)

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

OBSOLETE SELECTION GUIDE 1. Recommended alternative: OKY-T/10-W5P-C >> click here to download the data sheet

NMH Series Isolated 2W Dual Output DC/DC Converters

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

No. Test Requirement Test Condition Test Reference. 10 cycles

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W

SELECTION GUIDE. Nominal Input Voltage. Voltage Order Code1. Output

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Silvertel. Ag9912M Ultra Miniature PoE Module. 1. Features. 2. Description. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Series AM1P-Z 1 Watt DC-DC Converter

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code 1. V V ma

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

NCS6 Series Isolated 6W 4:1 Input Single Output DC/DC Converters

Positive Temperature Coefficient (PTC) Data Sheet

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Transcription:

Features Compliant to RoHS EU Directive Directive 2011/65/EU (Z versions) Compatible in a Pb-free or SnPb reflow environment (Z versions) RoHS Compliant Applications Distributed power architectures Wireless Networks Enterprise Networks Access and Optical Network Equipment Surface Mount and Through hole versions Common-mode and Differential-mode filtering Small size and low profile 48.3 mm x 25.4 mm x 11.7 mm (1.9 in x 1.0 in x 0.46 in) Same footprint as FLTR100V10 module Cost efficient open frame design Wide operating temperature range (-40 C to +85 C) Meets the voltage isolation requirements for ETSI 300-132-2 UL* 60950-1, 2 nd Ed. Recognized, CSA C22.2 No. 60950-1- 07 Certified, and VDE (EN60950-1, 2 nd Ed.) Licensed CE mark meets 2006/95/EC directives ISO** 9001 and ISO 14001 certified manufacturing facilities Options Surface Mount Interconnect (-S) Description The Filter module shall be designed to operate over an input voltage range up to 75Vdc at output current of 12A in an ambient temperature of -40ºC to 85ºC. The filter module shall be optimized for use with dc/dc converter modules, to significantly reduce the conducted differential and common-mode noise returned to the power source. The filter module shall enable designers to meet the requirements of EMI standards CISPR 22 (EN55022) and FCC Class B by inserting in-line between the power source and the dc/dc converter module. These modules shall be designed and manufactured to be either surface mounted(-s version) or through hole mounted on PCBs. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.v. ** ISO is a registered trademark of the International Organization of Standards This product is intended for integration into end-user equipment. All of the required procedures of end-use equipment should be followed. February 4, 2016 2016 General Electric Company. All rights reserved.

Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All VIN 0 75 Vdc Transient (100ms) VIN, TRANS 0 100 V Operating Ambient Temperature All TA -40 85 C Storage Temperature All Tstg -55 125 C I/O to Ground Isolation (100% Factory Tested) FLT012A0Z / FLT012A0-SZ 1500 Vdc FLT012A0-11Z - - 2000 Vdc Input to GND Insulation 10 - MΩ Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 0 24/48 75 Vdc Maximum Input-to-Output Current (VIN= 0 to ViN,max) All Imax 12 Adc Resistance per leg All R 20 mω Maximum Average Current (TA = 60 C, 2.03 m/s (400lfm) air) I max 12 A Maximum Average Current (TA = 60 C, natural convection) I max 8 A CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer s data sheet for further information. February 4, 2016 2016 General Electric Company. All rights reserved. Page 2

Insertion Loss Tables Standard Version Parameter Device Symbol Min Typ Max Unit Common-mode Insertion Loss 50Ω circuit, 500kHz All 41 45 db 50Ω circuit, 1MHz All 51 56 db 50Ω circuit, 10MHz All 69 75 db Differential-mode Insertion Loss 50Ω circuit, 500kHz All 50 55 db 50Ω circuit, 1MHz All 52 57 db 50Ω circuit, 10MHz All 48 53 db Insertion Loss Tables 11 version (2000V withstand) Parameter Device Symbol Min Typ Max Unit Common-mode Insertion Loss 50Ω circuit, 500kHz All 42 45 db 50Ω circuit, 1MHz All 52 56 db 50Ω circuit, 10MHz All 70 75 db Differential-mode Insertion Loss 50Ω circuit, 500kHz All 51 55 db 50Ω circuit, 1MHz All 53 57 db 50Ω circuit, 10MHz All 49 53 db General Specifications Parameter Min Typ Max Unit Calculated MTBF (VIN= VIN, nom, IO= 0.8IO, max, TA=40 C) Telecordia SR 332 Issue 2: Method 1, case 3 150,609,226 Hours Weight 12 (0.42) g (oz.) February 4, 2016 2016 General Electric Company. All rights reserved. Page 3

Characteristic Curves The following figures provide typical characteristics for the FLT012A0 Module. 0-10 -20-30 INSERTION LOSS (db) INSERTION LOSS (db) -40-50 -60-70 -80-90 -100 100k 1M 10M 30M FREQUENCY (MHz) Figure 1: Typical Common-Mode Insertion Loss in a 50Ω circuit (Standard Version, 100MHz Axis max.) FREQUENCY (MHz) Figure 4.: Typical Differential-Mode Insertion Loss in a 50Ω circuit.(-11 Option, 30MHz Axis max.) 0 INSERTION LOSS (db) -10-20 -30-40 -50-60 -70-80 -90-100 100k 1M 10M 30M FREQUENCY Figure 2: Typical Common-Mode Insertion Loss in a 50Ω circuit. (-11 Option, 30MHz Axis max.) OUTPUT CURRENT, Io (A) 14 12 10 8 6 4 2 Natural Convection 00.5m/s (100lfm) 1m/s (200lfm) 2m/s (400lfm) 0 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE, TA O C Figure 5. Derating Output Current versus Local Ambient Temperature and Airflow. INSERTION LOSS (db) INPUT 15Name 48 = 4 15Name 48 = 4 GROUND OUTPUT FREQUENCY (MHz) Figure 3: Typical Differential-Mode Insertion Loss in a 50Ω circuit. (Standard Version, 100MHz Axis max.) Figure 6. Internal Schematic February 4, 2016 2016 General Electric Company. All rights reserved. Page 4

Application Guidelines Conducted noise on the input power lines can occur as either differential-mode or common-mode noise currents. Differential-mode noise is measured between the two input lines, and is found mostly at the low frequency end of the spectrum. This noise shows up as noise at the fundamental switching frequency and its harmonics. Common-mode noise is measured between the input lines and ground and is mostly broadband noise above 10 MHz. The highfrequency nature of common-mode noise is mostly due to the high-speed switching transitions of power train components. Either or both types of noise may be covered in a specification, as well as a combination of the two. Differential-mode noise is best attenuated using a filter composed of line-to-line capacitors (X caps) and series inductance, provided by either a discrete inductor or the leakage inductance of a common-mode choke. In addition to the differential filtering provided by the filter module, it is recommended that an electrolytic capacitor be located at the converter side of the filter to provide additional attenuation of low-frequency differential noise and to provide a low source impedance for the converter, preventing input filter oscillations and load transient induced input voltage dips. Open-frame DC/DC converter modules and the older metalcased DC/DC converter modules require slightly different filtering arrangements. The FLT012A0 series of modules are optimized for the newer open-frame series of modules, but can also be used with older metal-case modules. The main differences in filtering recommendations between the two types of modules are in common-mode filtering, as explained below. Filtering Open-Frame DC/DC Converter Modules For filtering open-frame DC/DC converter modules, the recommended circuit is shown in Fig. 7. In addition to the input electrolytic filter capacitor C1 (recommended value is a minimum of 100uF and approximately 1uF/W at power levels above 100W), common-mode filtering capacitors C2 and C3 should be connected between the input and outputs as shown. Suitable values for common-mode capacitors C2 and C3 are in the range between 1000pF to 0.1µF are usually indicated in the DC/DC converter data sheet. These capacitors need to be rated for the isolation voltage desired between the input and output sides of the DC/DC converter module. The recommended power layout of the modules showing where the two common-mode capacitors are to be placed is shown in Fig. 8. VI(+) VI(-) Figure 7. Schematic diagram showing recommended connection of the FLT012A0 filter module with openframe DC/DC converter modules. Input V IN + V IN - CHASSIS GROUND FLT012A0 MODULE GND V O + V O - C 1 DC/DC CONVERTER MODULE VI+ C 2 DC/DC CONVERTER VI- C 3 V O + PLANE VO+ VO- Load V O PLANE Figure 8. Diagram showing recommended layout of the FLT012A0 filter module with open-frame DC/DC converter modules. Filtering Metal-Case DC/DC Converter Modules For metal-case DC/DC converter modules with a case pin, a different filtering arrangement and layout is recommended. Figure 9 shows the schematic diagram of the recommended circuit. The main difference with open-frame module is the use of an isolated shield plane located underneath the module which is connected through capacitors C2 through C5 to the input and output connections of the module. The shield plane along with the case of the module serves as a Faraday shield helping reduce EMI. The corresponding layout for metal-case modules is shown in Fig. 10. VI( +) VI(-) FILTER MODULE CHASSIS GROUND FILTER MODULE CHASSIS GROUND C1 C1 VI (+) VI (-) VI(+) VI(-) C2 C3 VO (+) DC/DC CONVERTER MODULE VO (-) VO(+) VO(-) CASE C2 C3 C4 C5 SHIELD PLANE Figure 9. Schematic diagram showing recommended connection of the FLT012A0 filter module with metalcased DC/DC converter modules. February 4, 2016 2016 General Electric Company. All rights reserved. Page 5

Input C 2 C 4 Load V IN + V O + VI+ VO+ V IN - FLT012A0 MODULE GND V O - C 1 DC/DC CONVERTER CASE SHIELD VI- PLANE VO- CHASSIS GROUND C 3 C 5 Figure 10. Diagram showing recommended layout of the FLT012A0 filter module with metal-case DC/DC converter modules. Example Data Showing Results using the FLT012A0 Modules Figure 11 shows example results obtained using a QBVW033 DC/DC converter module with the FLT012A0 filter module. The QBVW033 module is operated at an input voltage of 48V and output loading corresponding to an input current of 8.7A, a level close to the 12A capability of the FLT012A0 filter module. Board capacitance was as per recommendations in the QBVW033 datasheet. The results show that the filter module is capable of meeting EN55022 Class A limits with 11 db margin. Level [dbµv] 80 70 60 + x 50 40 + x + + x + x + x 30 20 10 0 150k 300k 500k 1M 2M 3M Frequency [Hz] 5M 7M 10M 30M x MES CE1220111019_fin QP + MES CE1220111019_fin AV MES CE1220111019_pre PK MES CE1220111019_pre AV Figure 11. Experimental results showing conducted EMI measured using a FLT012A0 module with a QBVW033 DC/DC converter. February 4, 2016 2016 General Electric Company. All rights reserved. Page 6

Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is shown in Fig. 12. Note that the airflow is parallel to the long axis of the module as shown in Fig. 12. Wind Tunnel 25.4_ (1.0) Figure 13. Tref Temperature measurement location. PWBs Power Module 76.2_ (3.0) x 12.7_ (0.50) Air flow Probe Location for measuring airflow and ambient temperature Figure 12. Thermal Test Set-up. The thermal reference point, Tref used in the specifications is shown in Figure 13. For reliable operation this temperature should not exceed 130 o C. The output power of the module should not exceed the rated output current of the module. Please refer to the Application Note Thermal Characterization Process For Open-Frame Board-Mounted Power Modules for a detailed discussion of thermal aspects including maximum device temperatures. February 4, 2016 2016 General Electric Company. All rights reserved. Page 7

Surface Mount Information Pick and Place The FLT012A0-SR SMT modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow temperatures of up to 300 o C. The label also carries product information such as product code, serial number and location of manufacture. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Even so, these modules have a relatively large mass when compared to conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and pick & placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 5 mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 8 mm max. time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/ir. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. REFLOW TEMP ( C) REFLOW TIME (S) Figure 15: Reflow Profile for Tin/Lead (Sn/Pb) process. MAX TEMP SOLDER ( C) Figure 14: Pick and Place Location. Bottom Side / First Side Assembly This module is not recommended for assembly on the bottom side of a customer board. If such an assembly is attempted, components may fall off the module during the second reflow process. Tin Lead Soldering The FLT012A0-SZ power modules are lead free modules and can be soldered either in a lead-free solder process or in a conventional Tin/Lead (Sn/Pb) process. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. In a conventional Tin/Lead (Sn/Pb) solder process peak reflow temperatures are limited to less than 235 o C. Typically, the eutectic solder melts at 183 o C, wets the land, and subsequently wicks the device connection. Sufficient Figure 16: Time Limit Curve Above 205 o C Reflow for Tin Lead (Sn/Pb) process. Lead Free Soldering The FLT012A0-SZ SMT modules are lead-free (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package February 4, 2016 2016 General Electric Company. All rights reserved. Page 8

(table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure. 17. Soldering outside of the recommended profile requires testing to verify results and performance. MSL Rating The FLT012A0-SRZ SMT modules have a MSL rating of 2a. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of <= 30 C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40 C, < 90% relative humidity. Reflow Temp ( C) 300 250 200 150 100 Per J-STD-020 Rev. C Heating Zone 1 C/Second Peak Temp 260 C * Min. Time Above 235 C 15 Seconds *Time Above 217 C 60 Seconds Cooling Zone 4 C/Second Post solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to GE Board Mounted Power Modules: Soldering and Cleaning Application Note.(AN04-001) Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHScompliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3 C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210 C. For Pb solder, the recommended pot temperature is 260 C, while the Pb-free solder pot is 270 C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your GE representative for more details. 50 0 Reflow Time (Seconds) Figure 17. Recommended linear reflow profile using Sn/Ag/Cu solder. February 4, 2016 2016 General Electric Company. All rights reserved. Page 9

Mechanical Outline Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] FLT012AZ (Through Hole Version) February 4, 2016 2016 General Electric Company. All rights reserved. Page 10

Surface Mount Outline Drawing February 4, 2016 2016 General Electric Company. All rights reserved. Page 11

Recommended Pad Layout Dimensions are in millimeters and [inches]. Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated) x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.] FLT012A0 (Through Hole Version) FLT012A0-SZ (SMT Version) February 4, 2016 2016 General Electric Company. All rights reserved. Page 12

Ordering Information Please contact your GE Sales Representative for pricing, availability and optional features. Table 1. Device Codes Device Code Input Voltage Range Output Current Connector Type Comcodes FLT012A0Z 0 75Vdc 12A TH CC109172202 FLT012A0-SZ 0 75Vdc 12A SMT CC109172210 FLT012A0-11Z 0 75Vdc 12A TH 150047449-11 refers to Special option with withstand voltage of 2000Vdc -Z refers to RoHS-compliant codes Contact Us For more information, call us at USA/Canada: +1 877 546 3243, or +1 972 244 9288 Asia-Pacific: +86.021.54279977*808 Europe, Middle-East and Africa: +49.89.878067-280 www.gecriticalpower.com GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. February 4, 2016 2016 General Electric Company. All International rights reserved. Version 1.27