TABLE OF CONTENTS 1. BEFORE YOU BEGIN...

Similar documents
1. Before You Begin What Is Included... 3 Unpacking Instructions Claims Product at a Glance... 3 Safety Instructions...

Snapshot. Hurricane 1300 USER MANUAL F-1300

Snapshot. User Manual BOB LED

LED Pinspot 2. Snapshot. User Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

1. Before you Begin Introduction Setup Operation Technical Information Returns...12

LED Pinspot 2. Snapshot. User Manual

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Bubble King. User Manual

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Bubble Machine. User Manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

CH-158 Color Bank 8 USER MANUAL

FL-2R MOVING HEAD 120W

Snapshot. SkyScan 4000 USER MANUAL

User Guide for Logo Projector

P/N Wheeler. user manual

HyperFlex 12G.

LED Twister II. User manual UK Version 1.0

QTFX-F1, QTFX-F2 FLAME EFFECT

ENGLISH Bumper Waves

Quick Reference Guide. English EN Español ES Français FR Nederlands NL

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

FX Shot ORDERCODE 60908

Measurements are expressed in millimeters.

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Installation & Operation Manual Chef Base

Verti Blast. User Manual. Order code: EQLED355

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

V1.0. Showven Technologies Co.,Ltd.

VF1000. User Instructions

FOG FURY FAZE. User Instructions

LED Moving Head Spot 60W LED / 30W LED. 1. Before you begin 1.1 Packing list. Mini moving head light

VF1000. User Instructions

USER MANUAL LUX-LD30W LED MOVING HEAD

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Light Source User Guide

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

FOG FURY 1000 II. User Instructions

VF FLURRY. User Instructions

MOVING HEAD. User manual CAUTION!

USER MANUAL PAR56 LED PAR CANS

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

American DJ. User Instructions. American DJ

ADJ Products, LLC - - Gobo Projector IR User Manual Page 3

Mania EF1 user manual

VF FLURRY. User Instructions

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench

ENGLISH PLE Chainhoist Controller

Model 700 Microarray Oven

Navigator ORDERCODE 40410

Edition Notes. Edition Notes. Trademarks CHAUVET, the Chauvet logo and Maverick MK2 Wash are registered trademarks or trademarks

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Elektralite LED Pro Line Pancake USER MANUAL (Version 2)

Light Source User Guide

H20 IR. User Instructions

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Mini Aquatic ORDERCODE 30844

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

Compact LED profile with zoom

OWNER S MANUAL Please read this manual before operating your power supply

INSTALLATION INSTRUCTIONS

American DJ. User Instructions. American DJ. Los Angeles, CA Charter Street

FlexChem Model 404 Rotating Oven

Operating Instructions. International English. CCS Dust Extractor

82V LITHIUM-ION BATTERY CHARGER GC 400

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

OBY-5. User manual MOVING HEAD CAUTION!

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Installation and Operation Manual

Electrical Installation

Cordless Rechargeable Saw Instructions for Use

3M Occupational Health & Environmental Safety Division 3M SoundPro Outdoor Kit Instructions

CLEAN POWER TM CPS Series Operator s Manual

Instruction Manual MINI IRRIGATION CONTROLLER.

DP140e. Installation & Operations Manual

Installation Instructions

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

Battery Powered Hydraulic Pump; Kit PN [ ]

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

NT-500 Technical Support Guide. For use by qualified company approved Technicians

WAVELIGHT -2 USER INSTRUCTIONS. Description:

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

1200W INVERTER GENERATOR

Operation Manual. Mega 4Bank DMX Universal

Operators Manual. Recirculating Chiller /06/08

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

The BVX-100 Fume Extraction System

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Owner Handbook. Nebula Blizzard v3. Snow Machine. L69500 Nebula Blizzard v3.indd 1 14/07/ :47

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

OPERATION INSTRUCTIONS

Transcription:

User Manual

TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 What is Included... 3 Unpacking Instructions... 3 Product at a Glance... 3 Safety Instructions... 4 2. INTRODUCTION... 5 Product Overview... 5 Product Dimensions... 6 3. SETUP... 7 AC Power... 7 Fuse Replacement... 7 Mounting... 8 Orientation... 8 Rigging... 8 4. OPERATING INSTRUCTIONS... 9 Manual Remote Operation (FC-M) (Optional)... 9 Timer Remote Operation (FC-T) (Standard)... 9 Wireless Controller (FC-W) (Optional)...10 General Troubleshooting...11 Contact Us...11 5. TECHNICAL INFORMATION...12 General Maintenance...12 Storage...12 Returns Procedure...13 TECHNICAL SPECIFICATIONS...14 Hurricane 1300 User Manual 2 Rev. 6

1. BEFORE YOU BEGIN What is Included 1 x Hurricane 1300 Power Cord 1 x FC-T wired timer remote 1 x Warranty Card 1 x Quick Reference Guide Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Claims The carrier is responsible for any damage incurred during shipping to this product or any part that shipped with it. Therefore, if the received merchandise appears to have damages caused during shipping, the customer must submit the damage report and any related claims with the carrier, not CHAUVET. The customer must submit the report upon reception of the damaged merchandise. Failure to do so in a timely manner may invalidate the customer s claim with the carrier. For other issues such as missing components or parts, damage not related to shipping, or concealed damage, the customer must make claims to CHAUVET within seven (7) days of receiving the merchandise. Product at a Glance Use on Dimmer x Auto Programs x Outdoor Use x Auto-ranging Power Supply x Sound-Active x Replaceable Fuse P DMX x User-Serviceable x Master/Slave x Duty Cycle x Hurricane 1300 User Manual 3 Rev. 6

Safety Instructions Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. This product is intended for indoor use only! (If applicable) To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating. The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source. Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles. Maximum ambient temperature (Ta) is 104 F (40 C). Do not operate fixture at temperatures higher than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Never connect the device to a dimmer pack. Make sure the power cord is never crimped or damaged. Never disconnect the power cord by pulling or tugging on the cord. Avoid direct eye exposure to the light source while it is on. There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-577-4455. FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Hurricane 1300. Make sure you use FCQ regularly to increase the life of your fogger. Hurricane 1300 User Manual 4 Rev. 6

2. INTRODUCTION Product Overview Hanging Bracket Fluid Container Handle Heater Nozzle Tilt Adjustment Knob Power switch Low Fluid indicator Manual controller Fluid level indicator Fuse holder Power input (hardwired) Manual Fog button Wireless Controller Hurricane 1300 User Manual 5 Rev. 6

Product Dimensions 317 mm / 12.5 in 425 mm / 16.7 in 306 mm / 12 in Hurricane 1300 User Manual 6 Rev. 6

3. SETUP AC Power To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart. A fixture s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture s requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use. Fuse Replacement Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse. This product has a replaceable fuse. In the event that the fuse needs to be replaced, follow the instructions provided below. 1. Using a flat head screwdriver, remove the fuseholder from the IEC housing. 2. Remove the bad fuse from the fuseholder. 3. Insert the new fuse into the fuseholder. 4. Install the fuseholder in the IEC housing. The fuse is located inside this compartment. Remove using a flat head screwdriver. Hurricane 1300 User Manual 7 Rev. 6

Mounting Orientation Rigging This fixture should only be mounted/used on a flat surface. This fixture may not be tilted. It is important never to obstruct the vents pathways. Mount the fixture using, a suitable C or O type clamp. When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. Safety cables must always be used, utilizing the provided safety eye bolt or hanging bracket. Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Hanging Clamp Angled Down Angled Up Note! Clamp is sold separately. Hurricane 1300 User Manual 8 Rev. 6

4. OPERATING INSTRUCTIONS Manual Remote Operation (FC-M) (Optional) 1. Plug in the fog machine to power and turn the power switch to the fixture on. 2. Plug in the wired manual remote to the Manual Controller socket on the rear of the fog machine. 3. Press the single button located on the remote to trigger the fog output. The button is momentary, which means that the fog machine will only output while the button is pressed. Once the button is released, the fog will stop outputting. Timer Remote Operation (FC-T) (Standard) This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. 1. Plug in the fog machine to power and turn the power switch to the fixture on. 2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine. 3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should light, indicating activation of function. 4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position. The INTERVAL is the time between bursts of fog. The DURATION is the time the fog machine will run during the burst. Interval Adjustment Timer LED Indicator Manual/Power LED Timer Latching Button Duration Adjustment Manual Momentary LED Manual control Momentary Continuous Latching Button Hurricane 1300 User Manual 9 Rev. 6

Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1. Plug the wires receiver into the fog machine 5-pin port labeled Wireless Controller. 2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button can be assigned to a different fog machine. You may only choose 1 dipswitch on each receiver. See the below configuration for setting the receivers to operate with the transmitter remote. Mode CH1 CH2 CH3 CH4 Dipswitches 1 = On, 2-4 = Off 2 = On, 1,3,4 = Off 3 = On, 1,2,4 = Off 4 = On, 1,2,3 = Off 3. Press the fog button, and the fog machine will output fog momentarily for as long as you hold down the button. LED indicator (ready) LED indicator (heating) Dipswitches Wireless Transmitter Fog Triggers Wireless Receiver Hurricane 1300 User Manual 10 Rev. 6

General Troubleshooting No Power Symptom No fog output Breaker/Fuse keeps blowing Low fog output Fog machine is not heating up Remote does not work Fluid indicator states no fog, but the container if full. Check mains power. Check external fuse. Check internal fuse. Solution(s) Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Run a cleaning solution through the fog machine. Check that the fog machine is plugged into the correct voltage. Check to replace the external fuse. Check to replace the internal fuse. Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Make sure connector is firmly connected to device. Try using another controller. Possible bad controller. Check the internal fuse. Check the external fuse. Try resetting the fog machine by turning the power off, and then on again. Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location listed below. Contact Us WORLD HEADQUARTERS - CHAUVET General Information Address: 5200 NW 108 th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll free: (800) 762-1084 Technical Support Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com World Wide Web www.chauvetlighting.com UNITED KINGDOM AND IRELAND - CHAUVET Europe Ltd. General Information Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115 Fax: +44 (0)1773 511110 Technical Support Email: uktech@chauvetlighting.com World Wide Web www.chauvetlighting.co.uk MEXICO - CHAUVET Mexico General Information Address: Av. Santa Ana 30 Parque Industrial Lerma Lerma, Mexico C.P. 52000 Voice: +52 (728) 285-5000 Technical Support Email: servicio@chauvet.com.mx World Wide Web www.chauvet.com.mx Outside the U.S., United Kingdom, Ireland, or Mexico, contact your dealer. Follow their instructions to request support or to return a product. Visit our website for contact details. Hurricane 1300 User Manual 11 Rev. 6

5. TECHNICAL INFORMATION General Maintenance Do not allow the fogger to become clogged. After every 40 hours of continuous operation, use CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning procedure is as follows. 1. Unplug the product from power. 2. Empty all fog fluid from the machine. 3. Add cleaning solution to the tank. 4. Connect the product to power and allow it to warm up. 5. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry. 6. Refill with fogger fluid to continue using the fogger. Run the machine briefly to clear any remaining cleaning solution from the pump and heater. Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane 1300. Make sure you use FCQ regularly to increase the life of your product. Storage Before storing the fogger, run FCQ through the system as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the fogger. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use. Test-run your Hurricane 1300 on a monthly basis to achieve the best performance. Hurricane 1300 User Manual 12 Rev. 6

Returns Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. If you are given a RMA #, please include the following information on a piece of paper inside the box: 1. Your name 2. Your address 3. Your phone number 4. RMA # 5. A brief description of the symptoms Hurricane 1300 User Manual 13 Rev. 6

TECHNICAL SPECIFICATIONS WEIGHT & DIMENSIONS Length... 16.7 in (425 mm) Width... 12.5 in (317 mm) Height... 12.0 in (306 mm) Weight... 16.8 lb (7.6 kg) POWER AC Power... 120 VAC 60 Hz or 230 VAC 50 Hz Fuse... 13 A, 250 V Power Consumption... 1,328 W (11.2 A) max at 120 V Inrush Power... (11.2 A) at 120 V Power Factor... 0.99 at 120 V Fuse... 7 A 250 V Power Consumption... 1,300 W (5.7 A) max at 230 V Inrush Power... (1.83 A) at 230 V Power Factor... 0.99 at 230V THERMAL Maximum ambient temperature... 104 F (40 C) CONTROL & PROGRAMMING Data input... 5-pin & ground DIN5 female socket Data pin configurationpin1(led), pin2(control), pin3(+5v), pin4(ground), pin5(none), ground(none) ORDERING INFORMATION Hurricane 1300... F1300 Wired manual remote (optional)... FC-M Wired timer remote (included)...fc-t Wireless manual remote (optional)... FC-W SPARE PARTS ORDERING INFORMATION Master PCB... P170-F3MSPCB Heater... 1P20-HT13 Pump... P200-F3PUMP Fluid container... P170-F3FLC Fluid sensor... P170-F1FLOS Thermal switch... P170-THEF11 Bracket knob...p111-f3bknob Fuse holder... P170-FUSEHOL Manual fog button... P111-F3FOGB WARRANTY INFORMATION Warranty... 1-year limited warranty Hurricane 1300 User Manual 14 Rev. 6