Application Note AN-1078

Similar documents
Hybrid Microcircuit Inherent Reliability for Space Applications

EMI INPUT FILTER 28 VOLT INPUT

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

Mechanical Integrity Issues of MCM-Cs for High Reliability Applications. Federal Manufacturing & Technologies. Howard Morgenstern, Tom Tarbutton, and

output Output Voltage min (ma)

Ultra Low Dropout Positive Adjustable Linear Regulator Hermetic Package + 3.3Vin at 3.0A

Features. Figure 1. EFIL-28 Connection Diagram

NOT RECOMMENDED FOR NEW DESIGNS

HIGH REPETITION RATE CHARGING A MARX TYPE GENERATOR *

Department of Electrical and Computer Engineering

Specialists in Power Electronic Components and Assemblies

Does V50 Depend on Armor Mass?

Energy Storage Commonality Military vs. Commercial Trucks

Application Note 103 January LTM4600 DC/DC µmodule Regulator Thermal Performance Eddie Beville, Jian Yin AN103-1

STEEL CASING OVERHEATING ANALYSIS OF OPERATING POWER PIPE-TYPE CABLES

Evaluation of Digital Refractometers for Field Determination of FSII Concentration in JP-5 Fuel

Technical Papers supporting SAP 2009

A Review of DC/DC Converter De-rating Practices

EVALUATING VOLTAGE REGULATION COMPLIANCE OF MIL-PRF-GCS600A(ARMY) FOR VEHICLE ON-BOARD GENERATORS AND ASSESSING OVERALL VEHICLE BUS COMPLIANCE

I m Tetsuji Yamanishi, Corporate Officer at TDK. Thank you for taking the time to attend TDK s performance briefing for the fiscal year ended March

ELECTRICITY: INDUCTORS QUESTIONS

Application Note AN-1203

MONITORING AND RESEARCH DEPARTMENT

RV-1805-C3 Application Note

Features. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage

APEC 2011 Special Session Polymer Film Capacitors March 2011

The Next Generation in High Reliability COTS DC-DC Converters

All-SiC Module for Mega-Solar Power Conditioner

Case Study Congestion Charges in Singapore

TOPOLOGY AND CONFIGURATION SELECTION FOR DC/DC CONVERTERS IN SPACE ELECTRICAL POWER SYSTEMS BASED ON COMPARATIVE RELIABILITY EVALUATION

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Feeding the Fleet. GreenGov Washington D.C. October 31, 2011

Vehicle Systems Engineering and Integration Activities - Phase 3

GM-TARDEC Autonomous Safety Collaboration Meeting

NOT RECOMMENDED FOR NEW DESIGNS

Additional Transit Bus Life Cycle Cost Scenarios Based on Current and Future Fuel Prices


Evaluation of SpectroVisc Q3000 for Viscosity Determination

Solar Power Energy Harvesting Electrical Integration

TECHNICAL INSTRUCTION HAC Rev N/C

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Helicopter Dynamic Components Project. Presented at: HCAT Meeting January 2006

products solutions powerful smart PRODUCT SELECTION GUIDE

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

NTA Series Isolated 1W Dual Output SM DC/DC Converters

Inverter Market Trends and Major Technology Changes

Selective Coordination

Synchronous Generators I. Spring 2013

COMPARISON OF HOIST DUTY SERVICE CLASSIFICATIONS

CHAPTER 1 INTRODUCTION

Automotive Micro and Mild Hybrids

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Synchronous Generators I. EE 340 Spring 2011

Features. Isolation PFM. Block Diagram

Innovative Power Supply System for Regenerative Trains

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

VEHICLE FLEET MANAGEMENT AT THE IDAHO NATIONAL ENGINEERING AND ENVl RONMENTAL LABORATORY

DC-DC CONVERTER. 5.1 Advantages & Disadvantages of DC-DC Converters

Rich, unique history of engineering, manufacturing and distributing

New Power Electronic Devices and Technologies for the Energy Sector

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

2011 NDIA GROUND VEHICLE SYSTEMS ENGINEERING AND TECHNOLOGY SYMPOSIUM POWER AND MOBILITY (P&M) MINI-SYMPOSIUM AUGUST 9-11 DEARBORN, MICHIGAN

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

THIS BULLETIN MODIFIES THE A4A BULLETIN , DATED DECEMBER 11, 2017

Sections: Monitoring your motors Where to look for savings Power factor improvement Voltage unbalance The Bottom Line...

Application Note TES 1 Series

Support for the revision of the CO 2 Regulation for light duty vehicles

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Course Name: Electric Drives Course Code: EE 701 Credit: 4

Lecture 1. Introduction to Power Electronics

Implications of Digital Control and Management for a High Performance Isolated DC/DC Converter

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

LESSONS LEARNED WHILE MEASURING FUEL SYSTEM DIFFERENTIAL PRESSURE MARK HEATON AIR FORCE FLIGHT TEST CENTER EDWARDS AFB, CA 10 MAY 2011

Shielding Effectiveness of Bal Spring Canted Coil Springs for EMI

Energy Conversion and Management

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

micro DC/DC Converter

Evaluation of Single Common Powertrain Lubricant (SCPL) Candidates for Fuel Consumption Benefits in Military Equipment

Electric cars: Technology

Cadmium Repair Alternatives on High-Strength Steel January 25, 2006 Hilton San Diego Resort 1775 East Mission Bay Drive San Diego, CA 92109

Impact of Advanced Technologies on Medium-Duty Trucks Fuel Efficiency

Circuits for Protecting and Triggering SCRs in High Power Converters

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W

1/7. The series hybrid permits the internal combustion engine to operate at optimal speed for any given power requirement.

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

New Inverter Layout and DC Link Capacitor Integration for Increased System Density and Performance

UL Certified RP30-FW

(RMG50) TO-220 Low-Profile Power Resistors. Token Electronics Industry Co., Ltd. Version: January 12, Web:

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W

DEFENSE AND AEROSPACE GUIDE

HiPer-tex fibre for light weight, cost effective blast and ballistic protection solutions

BIODIESEL. Lesson 4d Test biodiesel in a diesel generator. Developed by Engineering and Technology Curriculum Team

Re-refined Oil Definition Review Proposed Revision. California Assembly Bill 1195 (AB1195)

Market tendencies within industrial and mobile applications

Transcription:

Application Note AN-1078 An Examination of Changes Imposed by Revised Hybrid Models When Calculating MTBF Values using MIL-HDBK 217F, Notice 1 & 2 By Richard Miller, Director Space Products Table of Contents Page Resistors...1 Capacitors...1 Magnetics...2 Function Factor...3 Conclusions...4 Changes to the model incorporated in Revision F of MIL-HDBK-217 for estimation of hybrid failure rates result in a significant reduction of calculated MTBF values when compared to Rev E. Prompted by these reductions, a study was initiated which included a conversation with Seymour Morris of ROME Laboratory, who prepared the Rev F model created for hybrid microcircuits. MTBF calculations based on these models produce results that do not agree with those based on models presented in Revision E of MIL-HDBK-217. To illustrate this difference, calculated MTBF values are presented for the ART2815T DC/DC converter using MIL-HDBK- 217F Notice 2 and using MILHDBK- 217E. In addition, calculations are presented including application of various adjustments to the hybrid circuit model factors. The values resulting from each of these calculations are summarized for comparison in Table I following. The adjustments employed in these calculations and a discussion supporting their use in the 217F element model are presented for review. www.irf.com AN-1078 cover

International Rectifier 233 Kansas Street, El Segundo, CA 90245 USA AN-1078 An Examination of Changes Imposed by Revised Hybrid Models When Calculating MTBF Values using MIL-HDBK 217F, Notice 1 & 2 Richard Miller Director, Space Products 26 January, 1998 Changes to the model incorporated in Revision F of MIL-HDBK-217 for estimation of hybrid failure rates result in a significant reduction of calculated MTBF values when compared to Rev E. Prompted by these reductions, a study was initiated which included a conversation with Seymour Morris of ROME Laboratory, who prepared the Rev F model created for hybrid microcircuits. MTBF calculations based on these models produce results that do not agree with those based on models presented in Revision E of MIL-HDBK-217. To illustrate this difference, calculated MTBF values are presented for the ART2815T DC/DC converter using MIL-HDBK-217F Notice 2 and using MIL- HDBK-217E. In addition, calculations are presented including application of various adjustments to the hybrid circuit model factors. The values resulting from each of these calculations are summarized for comparison in Table I following. The adjustments employed in these calculations and a discussion supporting their use in the 217F element model are presented for review in the following narrative. 1. Resistors: Originally included in MIL- HDBK-217E, the mechanism for calculating the failure rate of hybrid thick-film substrate resistors has been eliminated from MIL-HDBK-217F. Since these resistors are an integral part of the hybrid substrate and are generally more reliable than the Established Reliability types used in non-hybrid circuits, they are considered to have a negligible effect on the overall failure rate and therefore, AA considers their exclusion justified. The hybrid model of 217F recommends that resistors not be included except when a hybrid is principally composed of passive components. As applied to DC/DC converters, AA concurs with this assessment. Including resistive elements in the calculation of MTBF has negligible effect on the calculated value. 2. Capacitors: The hybrid model presented in MIL-HDBK-217F assumes a www.irf.com 1

quality factor (π Q ) of 1.0 for each component and then applies an overall π Q of 0.25 to a class K hybrid. In the ART, the majority of ceramic chip capacitors incorporated are CDR types procured with a reliability level of S. The π Q given by MIL-HDBK-217F for CDR capacitors is 0.03, a value 1/8.3 times the π Q of 0.25 allowed for use in a hybrid. AA believes that no justification exists for penalizing the failure rate of such capacitors by boosting the quality factor by 8.3 times solely because they are used in a hybrid. Where noted in the attached table, a correction factor of 0.03/0.25 = 0.12 has been applied to the failure rate of all CDR type capacitors in order to override this penalty. In the original data sheet for the ART2815T, MTBF was calculated using MIL-HDBK-217F Notice 1. Extensive revisions were made in 217F Notice 2 to simplify the capacitor failure rate calculation. These revisions tripled the failure rate of CDR type capacitors. This change alone reduces the ART MTBF by 30% when comparing Notice 1 and Notice 2 versions of 217F. 3. Magnetics: All magnetic components used in AA DC/DC converters are constructed from materials rated for 200 C or higher. Derating per MIL-STD-975 limits the operating temperature to 150 C. The power transformer for the ART2815T has a measured hot spot temperature less than 33 C above the case temperature (when measured with a case temperature of approximately 100 C). All other inductive devices have a temperature rise of from 5 to 15 C above case. There are no known incidents of a field failure caused by a magnetic component in the ART type DC/DC converters. According to Seymour Morris of ROME Laboratory, the hybrid model created for 217F was not designed to include magnetic/inductive components and suggests that they not be included unless the circuit consists largely of passive components. Consequently, the ART data sheet MTBF was calculated per 217F Notice 1 ignoring the contribution of the magnetic elements. AA now believes that all magnetic components should be included in the calculation but should not be burdened with the additional function factor π F. Where noted in the attached table, a correction factor of 1/π F has been applied to the failure rate of the inductive components to yield an effective π F = 1.0. An increase in quality factor (π Q ) represents a decrease in MTBF. 2 www.irf.com

4. Function Factor, π F : The data used for creation of the 217F, Notice 1 hybrid model which led to the function factor (π F ) of 21 for power hybrids was collected largely from one hybrid manufacturer and consists mostly of process related failures involving seal, substrate attach, die attach and aluminum/gold intermetallic bonds. For AA DC/DC converter products which utilize qualified materials and processes (including industrial and military products representing tens of thousands of units shipped), there has been no known incident of any of these types of failures in the field. This includes the ART type converters and numerous other DC/DC products termed class H+ ( class H compliant with class K screening ). AA believes that classification as power hybrids imposing a function factor of 21 forces a high penalty on DC/DC converters not justified by experience. Since DC/DC converters are principally linear control circuits with few power components, the MTBF chould be calculated using a function factor of 5.8 (linear). For comparison purposes, a calculation globally applying p F = 21 and another applying a π F = 21 to the power devices and π F = 5.8 applied to the balance of the circuit is presented in options 4 & 5. Table I. Comparison of Failure Rate Calculations for ART2815T Option # Conditions, Assumptions & Exceptions (Env. = SF, T C = 45 C, V IN = 28V) Failure Rate ( per 10 6 Hours ) MTBF ( Hours ) 1 MIL-HDBK-217E Seal Perimeter = 8.75" Area = 1.742 in. 2 Bimetal interconnects = 155 Resistors = 62 2 MIL-HDBK-217F Notice 2 π F = 1.0 for Magnetics π F = 5.8 all other devices 3 MIL-HDBK-217F Notice 2 π F = 5.8 all devices ( incl. Mags. ) 4 MIL-HDBK-217F Notice 2 π F = 1.0 for Magnetics π F = 21 for Power Semiconductors π F = 5.8 all other devices 5 MIL-HDBK-217F Notice 2 π F = 21 all devices ( incl. Magnetics. ) 0.191775 5,214,439 0.189660 5,272,594 0.353735 2,826,973 0.355031 2,816,651 1.28077 780,783 www.irf.com 3

Conclusions: A comparison of MTBF values calculated using MIL-HDBK-217E and MIL- HDBK-217F Notice 2 shows a dramatic decrease in the calculated value. A detailed investigation of the model created for 217F Notice 2 provides substantial cause to question the assigned value of certain p factors and their application in the model. Calculated failure rates and justifications are presented for several altered factors. AA reliability engineers believe that one of the first four conditions selected from Table I above more reasonably represents an accurate model for calculation of MTBF for power DC/DC converters. For consistency of Rev F with Rev E calculations, Option 2 presents the most similar results. AA welcomes any comments, questions or suggestions. Details supporting any of the calculations listed above are available on request. WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105 http://www.irf.com/ Data and specifications subject to change without notice. 3/14/2005 4 www.irf.com