INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Similar documents
Detection of Gear Fault Using Vibration Analysis

Detection of Current consumption using Motor Current Signature Analysis

Design and Fabrication of a Gear Box Motor Current Analysis System

Design and analysis of a Gear Box Motor Current

Detection of Fault in Gear Box System using Vibration Analysis Method

FAULT ANALYSIS IN GEARBOX USING VIBRATION TECHNIQUE

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

Vibration Measurement and Noise Control in Planetary Gear Train

Motor Current Signature Analysis And Its Applications In

Determination Of Misalignment Using Motor Current Signature Analysis In Rotating Machine

Design Fabrication and Testing of Gearbox for Fault Detection.

Experimental Analysis of Faults in Worm Gearbox using Vibration Analysis

Analysis Of Gearbox Casing Using FEA

Effect of Multiple Faults and Fault Severity on Gearbox Fault Detection in a Wind Turbine using Electrical Current Signals

LOAD SHARING WITH PARALLEL INVERTERS FOR INDUCTION MOTOR DRIVE APPLICATION

Design and Development of Test Setup to Study the Basic Procedure of Vibration analysis

Presented by CJ Crabtree, Dr. W Yang, Prof. PJ Tavner 22 nd January 2009

DAMAGE IDENTIFICATION AND VIBRATION ANALYSIS TECHNIQUE FOR GEAR BOX

Analysis of Fault Diagnosis of Bearing using Supervised Learning Method

Condition Monitoring of Electrical Machines ABB MACHsense Solution

Diesel Engine Injector Faults Detection Using Acoustic Emissions Technique

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

55. Estimation of engine piston system wear using time-frequency method

International Journal of Advance Engineering and Research Development RESEARCH PAPER ON GEARBOX FAILURE ANALYSIS

Protection of Single Phase Induction Motor from Broken Rotor Bar and Thermal Overload

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

TWO PLANE BALANCING OF A CONICAL ROTOR DRIVEN BY VERTICAL BELT SYSTEM DESIGNED TO REDUCE GYRO EFFECT

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Improving predictive maintenance with oil condition monitoring.

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 2, March 2013

DESIGN OF THROTTLE BODY: A COMPARATIVE STUDY OF DIFFERENT SHAFT PROFILES USING CFD ANALYSIS

Gearbox Fault Detection

Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing

Trouble Shooting in Vertical Fire Hydrant Pump by Vibration Analysis - A Case Study

Adaptive Vibration Condition Monitoring Techniques for Local Tooth Damage in Gearbox

DESIGN AND ANALYSIS OF COMPOSITE LEAF SPRING

Condition Monitoring of a Check Valve for Nuclear Power Plants by Means of Acoustic Emission Technique

PROTECTION OF THREE PHASE INDUCTION MOTOR AGAINST VARIOUS ABNORMAL CONDITIONS

Speed Control of 3-Phase Squirrel Cage Induction Motor by 3-Phase AC Voltage Controller Using SPWM Technique

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

Design and Development of Gearbox Tester

Research on vibration reduction of multiple parallel gear shafts with ISFD

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

Investigation of Vibration on Suspension Systems at Different Load and Operating Conditions

Experimental Evaluations of the Dual-Excitation Permanent Magnet Vernier Machine

SIMPLE DIAGNOSTIC METHODS FOR DETECTING DAMAGED ROTOR BARS IN SQUIRREL CAGE INDUCTION MOTORS

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Optimization of Seat Displacement and Settling Time of Quarter Car Model Vehicle Dynamic System Subjected to Speed Bump

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Registration of the diagnostic signals of the starting system for selected faults

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

Induction Motor Condition Monitoring Using Fuzzy Logic

Thermal Analysis of Helical and Spiral Gear Train

Rotor Side Speed Control Methods Using MATLAB/Simulink for Wound Induction Motor

Control Scheme for Grid Connected WECS Using SEIG

The Study of Effect of Imbalance on Vibration of Rotor Bearing System

Comparative performance and emissions study of a lean mixed DTS-i spark ignition engine operated on single spark and dual spark

Dynamic Vibration Analysis of Gear Box Casing Using ANSYS Software

CHAPTER 1 INTRODUCTION

Study of Motoring Operation of In-wheel Switched Reluctance Motor Drives for Electric Vehicles

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

Vibration Analysis of Car Door Using FE and Experimental Technique

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

The time-frequency method of signal analysis in internal combustion engine diagnostics

Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

Experimental Analyses of Vibration and Noise of Faulted Planetary Gearbox

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

SEEDED FAULT DETECTION ON SPUR GEARS WITH ACOUSTIC EMISSION

Wind Turbine Emulation Experiment

A Comprehensive Study on Speed Control of DC Motor with Field and Armature Control R.Soundara Rajan Dy. General Manager, Bharat Dynamics Limited

Mathematical Modeling and Simulation of Switched Reluctance Motor

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Detection of broken rotor bars in three-phase squirrel-cage induction motor using fast Fourier transform

1. Introduction

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Impact of Bearing Vibration on yarn quality in Ring Frame

Positioning of Conveyor and Loadcell Measurement

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

Observations of Acoustic Emission activity during gear defect diagnosis. Tim Toutountzakis, David Mba

Investigation & Analysis of Three Phase Induction Motor Using Finite Element Method for Power Quality Improvement

ANALYSIS OF BLADES OF AXIAL FLOW FAN USING ANSYS. Mahajan Vandana N.,* Shekhawat Sanjay P.

G Prasad 1, Venkateswara Reddy M 2, Dr. P V N Prasad 3, Dr. G Tulasi Ram Das 4

The application of acoustic emission for detecting incipient cavitation and the best efficiency point of a 60 kw centrifugal pump: case study

Artesis MCM Case Studies. March 2011

Address for Correspondence

Analysis of Torque and Speed Controller for Five Phase Switched Reluctance Motor

Performance Analysis of Medium Voltage Induction Motor Using Stator Current Profile

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

The Gear Whine Noise and vibro-acoustic emission of gear-box

The Gear Whine Noise: the influence of manufacturing process on vibro-acoustic emission of gear-box

DESIGN OPTIMIZATION FOR VIBRATION LEVEL OF ROOT BLOWER WITH LOAD CONDITION

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics

Analysis of Multistage Linkage Based Eclipse Gearbox for Wind Mill Applications

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 2.114

A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

FUZZY LOGIC FOR SWITCHING FAULT DETECTION OF INDUCTION MOTOR DRIVE SYSTEM

Transcription:

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 ISSN 0976 6340 (Print) ISSN 0976 6359 (Online) Volume 3, Issue 2, May-August (2012), pp. 643-652 IAEME: www.iaeme.com/ijmet.html Journal Impact Factor (2012): 3.8071 (Calculated by GISI) www.jifactor.com IJMET I A E M E DETECTION OF GEAR RATIO AND CURRENT CONSUMPTION USING MOTOR CURRENT SIGNATURE ANALYSIS G DIWAKAR, Assoc professor Mechanical engineering Department, PVP Siddhartha Institute of Technology, Vijayawada, Andhra Pradesh, India garikapadi@yahoo.co.in M.V.H.Sathish Kumar Assoc professor Mechanical engineering Department, PVP Siddhartha Institute of Technology, Vijayawada, Andhra Pradesh, India sathish_movva@rediffmail.com ABSTRACT Dr..M R S Satyanarayana Vice Principal, Gitam University. Visakhapatnam, Andhra Pradesh, India..mrsmunukurthi@rediffmail.com. To achieve reliable and cost effective diagnosis, Motor current signature analysis is used to investigate the use of an induction motor as a transducer to indicate the faults in multistage gearbox via analyzing supply parameters such as phase current and instantaneous power. In gearboxes, load fluctuations on the gearbox and gear defects are two major sources of vibn. Further at times, measurement of vibn in the gearbox is not easy because of the inaccessibility in mounting the vibn transducers. This analysis system can be used for measuring the characteristics for a perfectly working gearbox and use the data as a standard for measuring faults and defects in other gearboxes. The objective of this paper is to design and fabricate a gearbox motor current analysis system at different gear opens on no load. No load conditions on the gearbox are tested for current signatures during different gear opens. Also found the minimum power required to run on different gears and gear. The motor current analysis system can be used further to specify mainly faults in the gear, misalignment of meshed gears, loss of contact of the gears and bearing wear. 1. INTRODUCTION The monitoring of a gearbox condition is a vital activity because of its importance in power transmission in any industry. Therefore, to improve upon the monitoring techniques for finding the gear s in the gearbox and the current passing through the motor running the gearbox has been a constant endeavor for improvement in these monitoring techniques. Techniques such as wear and debris analysis, vibn monitoring and acoustic emissions require accessibility to the gearbox either to collect 643

sles or to mount the transducers on or near the gearbox. But dusty environment, background noise, structural vibn etc. may her the quality and efficiency of these techniques. Hence, there is a need to monitor the gearbox away from its actual location, which can be achieved through Motor current signature analysis (MCSA) which has already been successfully applied to condition monitoring of induction motor for finding friction in bearings.[15] Personnel at Oak Ridge National Laboratory have found that MCSA can also provide information about system vibns and imbalances similar to the information provided by an accelerometer. As a result, MCSA techniques for monitoring the status of the equipment, such as pumps, compressors and gear drives driven by induction motors have been developed and used in dedicated monitoring systems. Also we can find in particular, if there are some faults in a gear box drive, the main current signal will be modulated by additional waveforms induced by fault components. [11] 2. LITERATURE REVIEW box fault detection can mainly be done through vibn and motor current analysis. The former method uses the fact that Vibn Faults, when they begin to occur, alter the frequency spectrum of the gear vibn. Particular faults are identified by recognizing the growth of distinctive sideband patterns in the spectrum. [1] The spectrum is recorded with the help of oscilloscope when the accelerometer is placed on the gearbox to be tested. The noise signature is affected by the background noise and the noise field.[5]these limitations of prevalent techniques bolster the justification of using the motor current signature analysis (MCSA), which has already been used for condition monitoring of motor operated valves of nuclear plants [3], [4], worm gears [5], induction motor and bearings [6] [11],and multistage gearbox [12], [13]. The basis of fault detection is the difference in normalized current RMS values of both healthy and faulty bearings. Broken rotor and eccentricity in the rotor and stator of an induction motor result in side bands of electric supply line frequency. Prior knowledge of spatial position of fault and the load torque with respect to the rotor is necessary as the effects of load torque and faulty conditions are difficult to separate. Motor current signals can be obtained from the outputs of current transducers which are placed non intrusively on one of the power leads. The resulting raw current signals are acquired by computers after they go through conditioning circuits and data interfaces. [14] These signals are then studied to determine faults occurring in gearbox. Although numerous techniques are available of non intrusive type of testing for fault detection, they have their own limitations. The present work thus aims to develop and propose a method which is simpler to find speed of gearbox and fault in gearbox by finding power consumption of motor. 3. EXPERIMENTAL SETUP The experimental set up consists of a four pole three-phase induction motor coupled to a 4-speed automotive gearbox. The coupling used is a shaft coupling. The input speed of the gearbox is the mechanical speed of the induction motor. Induction motor is also connected to dimmer stat which controls the power to the motor by varying the input voltage which further drives the gearbox output shaft. Then there are current probes to measure the current response. Voltmeter and an Ammeter are used here for measuring voltage and current readings. 644

Fig 1: Schematic diagram of Experimental setup. Description of various parts of the experimental setup is as follows: 1.3 Phase Induction Motor The motor has the following Configun, Make : Siemens Rated Power : 1.48 kw. Rated Speed : 1440rpm Frequency : 50 Hz. Voltage : 440 V. Current : 0.5 A. 2. Dimmer Stat Fig 2: DIMMER STAT used in the experiment 645

The DIMMER STAT used in the experiment has the following configun Type : 15D-3P Max KVA : 12.211 Connection for Max output voltage to input equal Input at A 1 A 2 A 3 V- 3-50/60HZ 415 Output at E 1 E 2 E 3 0-415 Volts Connection for Max output voltage higher than input Input at B 1 B 2 B 3 Output at E 1 E 2 E 3 Output current 15 per line 415 0-470 V-3-50/60HZ Volts 3: box A gearbox or transmission provides speed and torque conversions from a rotating power source to another device using gear s. The most common use is in automobiles where the transmission adapts the output of the internal combustion engine to the drive wheels. Such engines need to operate at a relatively high rotational speed, which is inappropriate for starting, stopping, and slower travel. The transmission reduces the higher engine speed to the slower wheel speed, increasing torque in the process. The gearbox used in the experiment is a 4-speed manual transmission automotive gearbox. Fig.3: 4-speed manual transmission gearbox 4: shaft coupling Shaft coupling is a coupling used to connect two rotating shafts of different diameters. The shaft is connected to one end at the motor and the other end at gearbox. 646

Fig.3: shaft coupled to motor and gearbox 5. FABRICATION The setup was placed on a Cast iron rectangular block. Induction motor and gearbox were connected on the rectangular block. Channel was used for placing the 3-phase induction motor so that the motor and the gearbox are properly aligned with each other. Both the motor and gearbox are coupled by a shaft so that the gearbox is fixed completely and does not vibrate during high rotational speeds. Fig 4: the Final fabricated set-up. 6. OBSERVATIONS The basic aim of the experimentation was to design the arrangement in order to predict the gear of the gearbox and to get the motor current signature of the input motor. For this the arrangement was done and the motor was made to run in various which was controlled by the dimmer stat. The motor was run on four different speeds between 1300 to1440 respectively and the speed of the driven shaft was measured using a Tachometer. 4 such readings were taken each for the 4 different gears. The results of the run are given in the table below: 1 st gear readings S.NO Voltage readings() Current readings() Motor box Overall Dimmer power % 1 112 6 1408 89.1 15.80 26 2 128 4 1424 90.7 15.70 15.75 28 3 138 2 1436 91.2 15.74 30 4 142 1442 92.7 15.55 31 647

2 nd gear readings S.NO Voltage readings() Current readings() Motor box Overall Dimmer power % 1 112 8 1382 138.8 9.95 23 2 116 7 1406 141.7 9.92 9.91 25 3 124 2 1422 143.5 9.90 27 4 136 1436 145.3 9.88 29 3 rd gear reading S.NO Voltage readings() Current readings() Motor box Overall Dimmer power % 1 116 0.53 1372 234.2 5.85 23 2 118 0.51 1388 237.1 5.85 5.85 24 3 124 7 1412 240.8 5.86 26 4 136 5 1430 244.3 5.86 29 4 th gear readings S.NO Voltage readings() Current readings() Motor box Overall Dimmer power % 1 124 0.58 1374 349.6 3.93 27 2 132 0.55 1400 353.1 3.96 3.95 29 3 148 0.51 1424 359.2 3.97 32 4 162 8 1434 362.9 3.95 34 Reverse gear readings S.NO Voltage readings() Current readings() Motor box Overall Dimmer power % 1 128 0.7 1346 90.7 14.84 28 2 136 4 1378 92.9 14.83 14.77 30 3 148 1402 95.2 14.72 32 4 160 0.54 1422 96.7 14.70 34 So the overall gear for the 4 speed manual transmission gearbox is: 1st gear: 15.75 2nd gear: 9.91 3rd gear: 5.85 4th gear: 3.95 Reverse gear: 14.77 From the data collected the current flow to the motor with the changing speed of motor, graphs are plotted with current vs. and voltage vs. of the driving shaft. With current & voltage on Y-axis and speed of the motor on X-axis 4 different graphs are plotted. 648

Graphs drawn for current vs.rpm at different speeds: 1 0.8 1st gear : 15.75 0.2 0 1400 1410 1420 1430 1440 1450 1 0.8 2nd gear : 9.91 0.2 0 1380 1400 1420 1440 1 0.8 3rd gear : 5.85 0.2 0 1350 1370 1390 1410 1430 1450 1 0.8 4th gear : 3.95 0.2 0 1350 1370 1390 1410 1430 1450 1 0.8 Reverse gear : 14.77 0.2 0 1320 1340 1360 1380 1400 1420 1440 649

Graphs drawn for voltage vs.rpm at different speed 150 150 140 1st gear : 15.75 140 2nd gear : 9.91 130 120 110 150 140 130 120 110 1400 1410 1420 1430 1440 1450 3rd gear : 5.85 1350 1370 1390 1410 1430 1450 130 120 110 180 160 140 120 1380 1400 1420 1440 4th gear : 3.95 1350 1370 1390 1410 1430 1450 190 170 150 130 110 Reverse gear : 14.77 1320 1340 1360 1380 1400 1420 1440 Graph drawn for I vs. no. of gears at 1400±5% Graphs drawn for V vs. no. of gears at 1400±5% 150 0.55 140 0.5 130 5 120 0 1 2 3 4 5 s 110 0 1 2 3 4 5 6 s 650

RESULTS It has been found that the motor current decreases with increasing input speed of gearbox. For low rpm of the input shaft the current withdrawn by the induction motor is maximum and minimum for high rpm of the input shaft. The decreasing motor current with increasing input speed is due to the fact that as the rpm increases the torque value decreases and so the current withdrawn by the induction motor decreases. For different gear s the plot of motor current vs input speed remains almost same. At constant speed current drawn from first gear to fourth gear increases and voltage decreases from 1 st gear to 4 th gear. CONCLUSIONS These plots can be taken as a standard for measuring defects in gearboxes. Any deviation from this plot means there is some defect in the gearbox which is tested. Vibn monitoring is affected by the base excitation motion because of the presence of a number of machinery in the factory. Moreover, because of the intricate location of the machine, there may be a problem of mounting transducers on the gearbox at times A method for continuously monitoring the condition of a motor and which interprets condition of faulty and healthy gear box. For future work, if there is any misalignment of the gears, or any gear tooth is broken then there is sudden upsurge in the current withdrawn by the induction motor can be determined using the developed system. REFERENCES [1] Early Detection of Faults Using Vibn Analysis in a Manufacturer's Test Department by Laszlo Boros, RABA, Gyor, Hungary and Glenn H. Bate, Bruel&Kjser, Denmark [2] N. Byder and A. Ball, Detection of gear failures via vibn and acoustics signals using wavelet transform, Mech. Syst. Signal Process., vol. 17, no. 4, pp. 787 804, Jul. 2003. [3] B. D. Joshi and B. R. Upadhyaya, Integrated software tool automate MOV diagnosis, Power Eng., vol. 100, no. 4, pp. 45 49, 1996. [4] S. Mukhopadhyay and S Choudhary, A feature-based approach to monitor motor-operated valves used in nuclear power plants, IEEE Trans.Nucl. Sci., vol. 42, no. 6, pp. 2209 2220, Dec. 1995. [5] D. M. Eisenberg and H. D. Haynes, Motor current signature analysis, in ASM Handbook, 10th ed, vol. 17. Materials Park, OH: ASM International, 1993, pp. 313 318. [6] M. E. H. Benbouzid, A review of induction motor signature analysis as a medium for faults detection, IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 984 993, Oct. 2000. [7], Bearing damage detection via wavelet packet decomposition of the starting current, IEEE Trans. Instrum. Meas., vol. 53, no. 2, pp. 431 436,Apr. 2004. [8] A. R. Mohanty and C. Kar, box health monitoring through three phase motor current signature analysis, in Proc. 4th Int. Workshop Struct.Health Monitoring, Stanford, CA, 2003, pp. 1366 1373. [9] C. Kar and A. R. Mohanty, Monitoring gear vibns through motor current signature analysis and wavelet transform, Mech. Syst. Signal Process., vol. 20, no. 1, pp. 158 187, Jan. 2006. 651

[10] Neeraj kumar EXPERIMENTAL INVESTIGATION OF FAULTY GEARBOX USING MOTOR CURRENT SIGNATURE ANALYSIS, may 2009.. [11] K. N. Castlcberry, High-Vibn Detection Using Motor Current Signature Analysis OAK RIDGE NATIONAL LABORATORY, sept. 09, 1996. [12] Mansaf R. Haram, box Fault Detection using Motor Current Signature analysis 1stYear PhD Supervised by Prof. A. Ball and Dr. F.Gu The University of Huddersfield,Queensgate, Huddersfield HD1 3DH, UK [13] A. R. Mohanty and Chinmaya Kar, Fault Detection in a Multistage box by Demodulation of Motor Current Waveform IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 53, NO. 4, AUGUST 2006 [14] R.B. Randal, State of the art in monitoring rotor machinery, Proceeding of ISMA, vol-iv, 2002, pp. 1457 1478. [15] G.Diwakar and V.Ranjith Kumar, DETECTION OF BEARING FAULT USING MOTOR CURRENT SIGNATURE ANALYSIS, ICMBD-2011, K L University. 652