three different ways, so it is important to be aware of how flow is to be specified

Similar documents
LogSplitterPlans.Com

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Hydraulic energy control, conductive part

Control of Heat Processes

Troubleshooting Bosch Proportional Valves

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Chapter 13: Application of Proportional Flow Control

Hydraulic Proportional and Closed Loop System Design

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Definitions of Technical Terms

Introduction. General Information. Systems Operation

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Servo and Proportional Valves

Components of Hydronic Systems

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Pneumatic & Hydraulic SYSTEMS

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

DENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information

Ch 4 Motor Control Devices

Infinitely Variable Capacity Control

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

Input, Control and Processing elements

Series PAVC Variable Volume, Piston Pumps

Axial Piston Variable Double Pump A8VO

SDigital vs. Analog Sensors

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

V Series AXIAL PISTON PUMP ORDER CODE

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Appendix A: Motion Control Theory

Proportional flow control valve 2-way version, Type 2FRE 10, Huade América 1

Torque Converter, Transmission Pump, Screen And Filter

LECTURE-23: Basic concept of Hydro-Static Transmission (HST) Systems

United States Patent 19 Schechter

2-way proportional throttle valve for block installation

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

Control Valves Positioner

Control Valves Positioner

S-SERIES DISPLACEMENT TRANSDUCERS

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

3406E Truck Engine 5EK01821-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/02/2008 Date Updated -07/02/2008

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle


Manual Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)

Appendix B. Glossary of Terms. Absolute pressure: The pressure above absolute pressure. It is the sum of atmospheric pressure and gauge pressure.

Name common, basic subsystems that compose

I) Clamping the work piece II) Drilling the work piece. III) Unclamping the work piece. 10

CENTAC Inlet and Bypass Valve Positioners

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Open Center Compact Valve Custom Installation Guide Rev A

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

Gold Cup Hydrostatic Transmission

International Journal of Advance Engineering and Research Development ADVANCE HYDRAULICS TECHNOLOGIES AND THEIR MODERN APPLICATIONS

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

350 Series Electrohydraulic Actuators

Systems Operation Testing and Adjusting

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

Proportional flow control valve 2-way versiontype 2FRE 6...RC

Air Management System Components

PROGRESSIVE CUSHIONING FOR HYDRAULIC CYLINDERS Michael Hanley Electro Hydraulic Machinery Co.

Appendix A. Standard Symbols for Hydraulic Components

Lecture 25 HYDRAULIC CIRCUIT DESIGN AND ANALYSIS [CONTINUED]

Steering unit LAGZ. Data sheet. Series 2 x

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Series PVP Variable Volume Piston Pumps

3/3-Way-Proportional Valve

Proportional, solenoid actuated flow control valves type SE and SEH

What does pressure refer to in relation to hydrostatics and what is it dependent on?

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

Type 310A-32A Pressure Reducing Regulator

Spring Cylinder Rotary Actuator

Safety for Hydraulics

2. Air Line AIR LINE FUEL INJECTION (FUEL SYSTEM) A: GENERAL B: MANIFOLD ABSOLUTE PRESSURE SENSOR FU(H4DOTC)-3

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

PNEUMATIC & HYDRAULIC SYSTEMS

Pilot operated proportional directional valves

Job Sheet 6 Pitch Control

Fuel Metering System Component Description

3. At sea level, the atmosphere exerts psi of pressure on everything.

t2_ il PioC Oper. led Relet Valve Symbol ~~~ CHAPTER 12 Pilot Operated Pressure Control Valves

1. Anti-lock Brake System (ABS)

A COMPARISON OF THE PERFORMANCE OF LINEAR ACTUATOR VERSUS WALKING BEAM PUMPING SYSTEMS Thomas Beck Ronald Peterson Unico, Inc.

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

Application Note Original Instructions Development of Gas Fuel Control Systems for Dry Low NOx (DLN) Aero-Derivative Gas Turbines

ANTI-LOCK BRAKES. Section 9. Fundamental ABS Systems. ABS System Diagram

Transcription:

Flow-control valves Flow-control valves include simple s to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature. The purpose of flow control in a hydraulic system is to regulate speed. All the devices discussed here control the speed of an actuator by regulating the flow rate. Flow rate also determines rate of energy transfer at any given pressure. The two are related in that the actuator force multiplied by the distance through which it moves (stroke) equals the work done on the load. The energy transferred must also equal the work done. Actuator speed determines the rate of energy transfer (i.e., horsepower), and speed is thus a function of flow rate. Directional control, on the other hand, does not deal primarily with energy control, but rather with directing the energy transfer system to the proper place in the system at the proper time. Directional control valves can be thought of as fluid switches that make the desired contacts. That is, they direct the highenergy input stream to the actuator inlet and provide a return path for the lower-energy oil. It is of little consequence to control the energy transfer of the system through pressure and flow controls if the flow stream does not arrive at the right place at the right time. Thus, a secondary function of directional control devices might be defined as the timing of cycle events. Because fluid flow often can be throttled in directional-control valves, some measure of flow rate or pressure control can also be achieved with them. Different types of flow measurement Controlling flow of a fluid-power system does not necessarily mean regulating volume per unit of time from a valve. Flow rate can be specified three different ways, so it is important to be aware of how flow is to be specified or measured: Volumetric flow rate, Q v, expressed in units of in. 3 /sec or min or cc/sec or cc/min in SI metric measure is used to calculate the linear speeds of piston rods or rotational speeds of motor shafts. Weight flow rate, Q w, expressed in units of lb/sec or lb/min, is used to calculate power using English units of measure. Mass flow rate, Q g, expressed in units of slugs/sec or slugs/min for English measure or kg/sec or kg/min in SI metric measure is used to calculate inertia forces during periods of acceleration and deceleration. Because they control the quantity of fluid that flows through the valve per unit of time, the same control valves are used for all three types of flow rates. Control of flow rate with valves There are eight types of flow-control valves: Orifices A simple in the line, Figure 1(a), is the most elementary method for controlling flow. (Note that this is also a basic pressure control device.) When used to control flow, the is placed in series with the pump. An can be a drilled hole in a fitting, in which case it Fixed (a) is fixed; or it may be a calibrated needle valve, in which case it functions as a variable, Figure 1(b). Both types are non-compensated flow-control devices. Flow regulators This device, Figure 2, which is slightly more sophisticated than a fixed, consists of an that senses flow rate as a pressure drop across the ; a compensating piston adjusts to variations in inlet and outlet pressures. This compensating ability provides closer control of flow rate under varying pressure conditions. Control accuracy may be 5%, possibly less with specially calibrated valves that operate around a given flow-rate point. Bypass flow regulators In this flow regulator, flow in excess of set flow rate returns to reservoir through Variable (b) Fig. 1. Simple fixed (a) and variable (b) flow controls. Fig. 2. Flow regulator adjusts to variations in inlet and output pressures. A/82

a bypass port, Figure 3. Flow rate is controlled by throttling fluid across a variable regulated by the compensator piston. The bypass flow regulator is more efficient than a standard flow regulator. Demand-compensated flow controls Flow controls can also bypass excess system flow to a secondary circuit, Figure 4. Fluid is routed at a controlled flow rate to the primary circuit, and bypass fluid can be used for work functions in secondary circuits without affecting the primary one. There must be flow to the primary circuit for this type of valve to function if the primary circuit is blocked, the valve will cut off flow to the secondary circuit. Pressure-compensated, variable flow valves This flow control is equipped with an adjustable variable placed in series with a compensator. The compensator automatically adjusts to varying inlet and load pressures, maintaining an essentially constant flow rate under these operating conditions to accuracies of 3 to 5%, Figure 5. Pressure-compensated, variable flow-control valves are available with integral reverse-flow check valves (which allow fluid to flow unrestricted in the opposite direction) and integral overload relief valves (which route fluid to tank when a maximum pressure is exceeded). Pressure- and temperature-compensated, variable flow valves Because the viscosity of hydraulic oil varies with temperature (as do the clearances between a valve s moving parts), output of a flow-control valve may tend to drift with temperature changes. To offset the effects of such temperature variations, temperature compensators adjust the control openings to correct the effects of viscosity changes caused by temperature fluctuations of the fluid, Figure 6. This is done in combination with adjustments the control for pressure changes as well. Priority valves A priority valve, Figure 7, is essentially a flow-control valve that supplies fluid at a set flow rate to the primary circuit, thus functioning as a pressure-compensated flow-control valve. Flow in excess of that required by the primary circuit bypasses to a secondary circuit at a pressure somewhat below that of the primary circuit. Should inlet or load pressure (or both) vary, the primary circuit has priority over the secondary as far as supplying the design flow rate is concerned. Deceleration valves A deceleration valve, Figure 8, is a modified 2- way, spring-offset, cam actuated valve used for decelerating a load driven by a cylinder. A cam attached to the cylinder rod or load closes the valve gradually. This provides a variable that gradually increases backpressure in the cylinder as the Handwheel Inlet Drain Bypass Regulated flow Fig. 3. Bypass flow regulator returns excess flow from pump to tank. Fig. 5. Pressure-compensated, variable flow-control valve adjusts to varying inlet and load pressures. Compensator piston Fixed Secondary circuit Primary circuit Adjustable Temperature-sensitive element Fig. 4. Demand-compensated flow control bypasses full pump output to tank during idle portion of work cycle. Fig. 6. Pressure- and temperature-compensated, variable flow-control valve adjusts the size to offset changes in fluid viscosity. 2003 Fluid Power Directory A/83

valve closes. Some deceleration valves are pressure-compensated. Other flow controls Flow dividers A flow-divider valve is a form of pressure-compensated flow-control valve that receives one input flow and splits it into two output flows. The valve can deliver equal flows in each stream or, if necessary, a predetermined ratio of flows. The circuit in Figure 9 shows how a flow divider could be used to roughly synchronize two cylinders in a meter-in configuration. Like all pressure- and flow-control devices, flow dividers operate over a narrow bandwidth rather than at one set point. Thus, flow variations in the secondary branches are likely. Therefore, precise actuator synchronization cannot be achieved with a flow-divider valve alone. Flow dividers can also be used in meter-out circuit configurations or cascaded connected in series to control multiple actuator circuits, Figure 10. Pilot pressure Circuit 1 Circuit 2 Which flow control to use for an application Application Type of flow-control valve Load on the actuator and supply pressure both are constant: ±5% accuracy Load on the actuator, supply pressure, or both undergo changes: ±3-5% accuracy Load on the actuator, supply pressure, or both change, and fluid temperature varies ±30 F (±17 C): ±3-5% accuracy The best type of flow control valve to use depends on the design parameters of the application. Above are general guidelines based on common application characteristics. Pilot pressure Fig. 7. Priority valve supplies fluid at a set rate to a primary circuit. Rotary flow dividers Another technique for dividing one input flow into proportional, multiple-branch output flows is with a rotary flow divider. It consists of several hydraulic motors connected together mechanically by a common shaft. One input fluid stream is split into as many output streams as there are motor sections in the flow divider. Because all motor sections turn at the same speed, output stream flow rates are proportional and equal to the sum of displacements of all the motor sections. Rotary flow dividers can usually handle larger flows than flow divider valves. The pressure drop across each motor section is relatively small because no energy is delivered to an external load, as is the usual case with a hydraulic Non-compensated, fixed or variable flow control, depending on application Pressure-compensated, fixed or variable flow control, depending on application Pressure- and temperature-compensated, fixed or variable flow control motor. However, designers should be aware of pressure intensification generated by a rotary flow divider. If, for any reason, load pressure in one or more branches drops to some lower level or to zero, full differential pressure will be applied across the motor section in each particular branch. The sections thus pressurized will act as hydraulic motors and drive the remaining section(s) as pump(s). This results in higher (intensified) pressure in these circuits branches. When specifying rotary flow dividers, system designers must be careful to minimize the potential for pressure intensification. A pressure relief valve should be placed in any actuator fluid line where this condition may occur. Rotary flow dividers can also integrate multiple branch return flows into a single return flow. Proportional flow-control valves Proportional flow-control valves combine state-of-the-art hydraulic Flow divider Cam roller Adjustable bypass Fig. 8. Deceleration valve slows load by being gradually closed by action of cam mounted on cylinder load. Fig. 9. Linear-type flow divider splits single input into two output flows. A/84

valve actuation with modern, sophisticated electronic control. These valves help simplify A 2 hydraulic cir- cuitry by reducing the number of components a system may require while, at the same time, substantially increasing system accuracy and efficiency. An electronically controlled, proportional flow-control valve modulates fluid flow in proportion to the input current it receives. The valves can easily control cylinders or smaller hydraulic motors in applications that require precise speed control A P 1 or controlled acceleration or deceleration. Most proportional flow-control valves are pressure-compensated to minimize flow variations caused by changes in inlet or outlet pressure. An electrohydraulic proportional valve consists of three main elements: a pilot or proportional solenoid a metering area (where the valve spool is located), and Fig. 11. Circuit diagram for pressure-compensated flow-control valve. P 2 Compensator spool an electronic position-feedback device, often an LVDT (linear variable differential transformer). Valve operation begins when it receives a signal from an outside controlling device such as a computer, programmable logic controller (PLC), traditional logic relay, or potentiometer. The control device delivers analog electrical signals to the valve driver Fig. 10. Flow dividers can be cascaded in series to control multiple actuator circuits. A 3 C P 3 card, which, in turn, sends a current signal to the solenoid on the valve. The electromechanical force on the spool causes it to shift, gradually opening a flow path from the pump to B the actuator port. The greater the command input signal, the greater the current to the valve solenoid, and, thus, the higher the flow from the valve. The important feature of this proportional valve is that all elements are proportional; thus, any change in input current changes force signals proportionately as well as the distance the valve spool will shift, the size of the flow path, the amount of fluid flowing through the valve, and finally the speed at which the actuator moves. As the spool shifts, its motion is detected and monitored very accurately by an LVDT or other type of positionfeedback transducer. This signal is fed back to the driver card where it is continuously compared with the input signals from the controller. If the two differ, the driver adjusts spool position until the two signals match. Pressure-compensated proportional flow-control valves are 2-port valves in which the main control is adjusted electronically. Similar to conventional pressure-compensated flow-control valves, a pressure-compensated proportional flow-control valve maintains constant flow output by keeping the pressure drop constant across the main control. The proportional valve, however, is different in that the control is modified to work in conjunction with a stroke controlled solenoid. In a 2-port, pressure-compensated proportional flow-control valve, an electrically adjustable control is connected in series with a pressure reducing valve spool, known as a compensator, Figure 11. The compensator is located upstream of the main control and is held open by a 2003 Fluid Power Directory A/85

Proportional solenoid Pilot control Spring chamber Amplifier Fig. 12. Cross-sectional view of proportional flow logic valve. light spring. When there is no input signal to the solenoid, the light spring force holds the main control closed. When the solenoid is energized, the solenoid pin acts directly on the control, moving it downward against the spring to open the valve and allow oil to flow from port A to port B. At the same time, the LVDT provides the necessary feedback to hold position. In this case, the LVDT provides feedback to maintain a very accurate setting. Pressure compensation is achieved by incorporating a pilot passage at the inlet of the valve that connects to one side of the compensator spool, A 2. There is another pilot passage located A B near the outlet of the valve beyond the control, and it is connected to the opposite side of the compensator spool, A 3. A bias spring on this side of the spool keeps the compensator in the LVDT open position. Load-induced pressure at the Cover outlet port or pressure deviations at the inlet port modulate Sleeve the compensator spool to increase or decrease the Main piston pressure drop across the compensator s metering. Acting as a pressure reducing valve, the compensator ensures that the main control sees a constant pressure drop. When the pressure drop is constant, the flow remains constant. The amplifier provides time controlled opening and closing of the. For reverse free-flow, check valve C, built into the valve, provides a flow path from port B to A. Proportional flow-control valves are also available with either linear or progressive flow characteristics. The input signal range is the same for both. However, the progressive flow characteristic gives finer control at the beginning of adjustment. In case electrical power or feedback is lost, solenoid force drops to X zero and the force exerted by the spring closes the. When feedback wiring is connected incorrectly or damaged an LED indicates the malfunction on the amplifier card. Proportional flow logic valves Proportional flow-control logic valves are basically electrically adjustable flow controls that fit into a standard logic valve cavity. The cover and cartridge are assembled as a single unit, with the cover consisting of a proportional force solenoid and a pilot controller, Figure 12. When an electrical signal is fed into an electronic amplifier, the solenoid and controller adjust the pilot pressure supplied from port A to change spool position. An LVDT then feeds back the position to the amplifier to maintain the desired condition for flow from port A to port B. The proportional logic valve is available with either linear or progressive flow characteristics, and the valve drivers respond to voltage (0- to 10-V DC) or current (0- to 20-mA) command signals. The typical valve amplifier card requires a 24-V DC power supply. Because the valve remains relatively unaffected by changes in system pressure, it can open and close the in the same length of time. This maximum time can be changed on the amplifier card by adjusting a built-in ramp generator. The amplifier can be used in several ways. An external potentiometer can make the remotely adjustable while maximum spool acceleration is still limited by this internal ramp; or a limit switch can be added to turn the ramp on and off. In case of power failure, the element will return to its normally closed position. A/86