TECHNICAL INFORMATION LOW FLOW METER. (ethylene propylene rubber) optional. Valve trim (seat and stem) is 316 stainless.

Similar documents
VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

SINGLE TUBE FLOW METERS

TUBE FLOW METERS. design features INTERCHANGEABLE. 150 mm Meter with CV TM Valve

Glass Tube Full-View Flowmeters

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

King Instrument Company opened its doors in 1983 with one major goal:

DIAPHRAGM SEALS. MHP SERIES MINI HIGH PRESSURE Mini diaphragm seal for pressures up to 6000 psi

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Model BPS-09-Npt. Stainless Steel Back Pressure Bypass Valve

Ball and Stem Materials: 316 Stainless Steel Alloy 20 Monel Hastelloy C. Service Applications: Hydraulics Chemical

Thermo Scientific Gilmont

Flow Limit Safety Shutoff Valves Model 1

KDG/KDF - Flow Meter and Flow Switch

Check Valves BALL TYPE

5100 Series Inline Relief Valve 10 to 2,400 PSIG

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) Description

Taking care of the world s water. Wallace & Tiernan Products Chemtube 2000 Hydraulic Diaphragm Metering Pump

Variable Area Flowmeters Ori-Flowrator TM Meters

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

DAKOTA INSTRUMENTS OPERATING MANUAL ACR ACRYLIC FLOW METERS

Self-Operating Temperature Regulators

Model descriptions. Technical data. Pressure and Temperature Limits Models 19, 20, 20P: -60 to 406 F Models 19M, 20M, 20MP:

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

O-Rings. Back pressure may be required to reseal the valves with nominal cracking pressure of 5psi or lower.

P99 Pressure Reducing Regulator

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Spray Nozzle. QuickJet and Systems/Components. Features and Benefits. Accessories

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

metering valves Metering Valves Index 1300 Series Series Series 8

P200 Pressure Regulator

TABLE OF CONTENTS PRODUCT CONTENTS PAGE. GFH45 Filter Regulator FR95 Filter Regulator GFX02 Filter GFX04 Filter

ENCORE 700 DIAPHRAGM METERING PUMP

Check valve series. SHCV, SOCV, SOACV, SACV Series. Phone: Fax: Wimbledon Rd.

DW PADDLE-BELLOWS FLOWMETER & SWITCH

SERIES G603 STANDARD FRONT MOUNT GAGE

ECLIPSE TURBO BLOWERS SERIES SMJ

Series Regulators - Pressure Reducing

T200 Pressure Regulator

Product Engineering Guide

Model BPS05-Npt-P. Plastic Back Pressure Regulator Valve

TEXAN SUPPLY VALVE & Whatever you need we can supply

P627 High Flow Gas Regulator

LEVEL CONTROL SWITCHES

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

GENERAL PURPOSE PANEL MOUNT GENERAL PURPOSE IN-LINE

Glass Tube Full-View Flowmeters

Hard Seat Fluid Pressure Regulator

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Cartridge Filter Housings Nowata A Series

Industrial Turbo Meters, Sizes 2" through 6"

Ar-Mite TM Low Flow Armored Flowmeter

P200 Pressure Regulator

OIL BURNER NOZZLES

DUAL SEAL PLUNGER PNEUMATIC OPERATION HIGH FLOW TURNDOWN INTRINSICALLY SAFE GREATER RELIABILITY

CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS

D/G-04 Series. Up to 3.0 gpm (11.3 l/min)

Product overview. Technical data

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

* Contact your sales representative for compliance to NACE MR or later requirements.

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

R627 High Flow Gas Regulator with Internal Relief

Introduction to Inline Lubrication. Master Pneumatic

Variable Area Flowmeters Armored Purgemeter

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

D/G-12 Series. Up to 8 gpm (30.3 l/min)

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

Installation, Operation, and Maintenance Manual

Pressure Control Valves

DUAL SEAL PLUNGER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

More Drum Gauge Features

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Type B TM Rupture Disk. Type. Solid Metal Rupture Disks. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information

needle valves Needle Valves

needle valves Needle Valves

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

* Contact your sales representative for compliance to NACE MR or later requirements.

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DUAL SEAL PLUNGER. Re Req u i r e m e n t s. S e r i e s o f M e t e r i n g P u m p s

Inline Adapters are Electro Polished to 10 Ra Max. 2 Valves supplied with Metal to Metal Face Seal connections have

Diaphragm Seals TYPE12. Tri-Clamp Sanitary Pressure

F300 Pressure Regulator

ANDERSON GREENWOOD. Flow Control. Anderson Greenwood Tank and Equipment Blanketing Systems. Pad Valves. De-Pad Valves. Total Flow Control Solutions

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

check valves BIVCO Check Valves

TWO-PRESSURE VALVE ASSEMBLY

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Applications. T98H Part Matrix. Specifications. Spring Range. Materials of Construction. T98H Regulator Rebuild Kits. marshbellofram.

Low Profile Insertion Vortex

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Transcription:

TECHNICAL INFORMATION LOW FLOW METER FEATURES Wallace & Tiernan Products Purge Meters are low-flow variable area meters which incorporate several improvements in basic design. They feature an unusually rigid, corrosion resistant stainless steel frame and a positive, easily controlled tube lock. Low Flow Meters are specifically designed for low flow applications in research and industry. For higher capacities, write for TI 520.100 describing the Glass Tube Varea-Meter. For high temperature, high pressure, or hazardous fluid metering, write for publication TI 520.205 on the Metal-tube Varea-Meter or 520.215 on the TFE-lined and PVC-tube Varea-Meters. STRUCTURALLY STRONG FRAME The side frames are heavy, channel-form stainless. steel sections welded to stainless end fittings turned from bar stock. This produces a rigid unit which resists pipe strains and protects tube alignment. CHOICE OF CORROSION- RESISTANT MATERIALS The frame is made of 302 stainless steel; the end fittings, 316 stainless. The metering-tube retainer is Kynar vinylidene fluoride resin with 316 stainless optional. O-rings come in a choice of Buna N or Viton with EPR (ethylene propylene rubber) optional. Valve trim (seat and stem) is 316 stainless. POSITIVE TUBE LOCK AND A TUBE SHIELD A knurled tube-locking nut, external to the flow, positions the tube retainer and locks the tube firmly in place. Tube removal is quick and easy. O-rings seal the tube at both ends. A clear plastic shield covers the tube. It has tabs which snap into slots in the frame. VERSATILE FLOW CONTROLLER A W&T Flow Controller keeps flow constant regardless of pressure variations. It comes in brass or 316 stainless steel, in inlet or outlet configurations and high or low capacities. Replaceable seat adapters make for easy capacity changes. Straight-through design means the controller can be threaded directly into the meter body, eliminating pipe nipples and static piping.

SELECTION PROCEDURE Determine the capacity range, temperature and pressure capability, materials of construction, and options required for each meter. See Technical Data Section for pressure and temperature limits. Note: For fluids with SP.GR. other than 1.0 or viscosity other than 1.0 CSS consult your local U.S. Filter Wallace & Tiernan Products Varea-Meter Distributor. TABLE A - ORDERING NUMBERS FOR BASIC METER ARRANGEMENTS CAPACITY FUNCTION EXTRA LOW 1.9 ccm H 2 O or METER ONLY 130 sccm air METER WITH maximum CONTROL VALVE 316 STAINLESS END FITTINGS BUNA N O-RINGS VITON O-RINGS 20 30 NOT AVAILABLE LOW METER ONLY 20 30 2.7 GPH H 2 O or METER WITH VALVE TRIM 316 SS 316 SS 14.0 scfh air CONTROL WITH KNOB 22 32 maximum VALVE WITH SLOT 26 36 HIGH METER ONLY 20 30 40 GPH H 2 O or METER WITH VALVE TRIM 316 SS 316 SS 115 scfh air CONTROL WITH KNOB 24 34 maximum VALVE WITH SLOT 28 38 ORDERING NUMBERS FOR TABLE C - ORDERING NUMBERS FOR TABLE B - TUBES, SCALES AND FLOATS - WATER TABLE C - TUBES, SCALES AND FLOATS - AIR MAXIMUM CAPACITY TUBE, SCALE AND FLOAT AND SCALE UNITS FLOAT NUMBER MATERIAL MAXIMUM CAPACITY TUBE, SCALE AND FLOAT AND SCALE UNITS FLOAT NUMBER MATERIAL EXTRALOW CAPACITY HIGH CAPACITY LOW CAPACITY 0.375 ccm 0-100% C016 Sapphire 0.875 ccm 0-100% C026 1.9 ccm 0-100% C036 Tantalum 7.0 ccm B046 Black 0-100% C046 Glass 0.5 gph A056 32 ccm B056 0-100% C056 66 ccm B066 Black 0-100% C066 Glass 2.7 gph A076 170 ccm B076 0-100% C076 8.4 gph A086 540 ccm B086 0-100% C086 15.0 gph A096 960 ccm B096 0-100% C096 26.0 gph A106 1650 ccm B106 0-100% C106 40.0 gph A116 2600 ccm B116 Tantalum 0-100% C116 EXTRALOW CAPACITY HIGH CAPACITY LOW CAPACITY 50 sccm 0-100% D016 Sapphire 80 sccm 0-100% D026 130 sccm 0-100% D036 Tantalum 1.2 scfh E046 Black 0-100% D046 Glass 2.7 scfh A056 0-100% D056 7.0 scfh E066 Black 0-100% D066 Glass 14.0 scfh E076 0-100% D076 21.0 scfh E086 Black 0-100% D086 Glass 40.0 scfh E096 0-100% D096 60.0 scfh E106 0-100% D106 115.0 scfh E116 0-100% D116 Note: For special calibrations of low and high capacity meters, the first digit of the tube, float and scale code is an L for liquid service and a G for gas service. WARNING: Do not use Glass-Tube Meters for fluids which are toxic, hazardous or attack glass. 3

Features Continued INTEGRAL BACKCHECK An anti-backflow device is built into the discharge. It consists of a 316 stainless steel poppet with a Buna N or Viton O-ring seal. This allows easy maintenance on tube and float. HIGH INTERCHANGEABILITY All parts, except tubes, frames, and plastic shields, are interchangeable regardless of scale length. Tubes have same size O-rings at each end. The tubes for all capacities fit one frame size. This and the one-piece frame make for design simplicity with simplified maintenance and spare parts stocking. CHOICE OF ARRANGEMENTS AND OPERATING POSITION Low Flow Meters can be supplied with: an integral flow control valve with a screwdriver-slot stem or a knob for adjustment; a factory-connected flow controller to maintain flows constant; and a plastic bezel for flush panel mounting. The meter can be inverted and its tube reversed to change the control valve from the inlet to the discharge. VERSATILE CONTROL VALVE The optional control valve has a common stem with high- or low-capacity seats; all are 316 stainless. An O-ring in the seat makes it easy to change. The valve gives smooth adjustment and a fine degree of control. 2

ORDERING PROCEDURE EXAMPLE To order a low capacity meter with control valve with knob, 316 stainless trim and Buna N O-rings, specify 22. To order a tube with a capacity of 32 ccm water and scale units in ccm add B056. Add S for standard O-ring material. Add S for standard Kynar tube retainer. Add X for no flow controller, 2 for bezel to accommodate meter with control valve, and 2 for control vale at meter inlet. Thus the complete ordering number is: 22B056 SSX22. 1 2 3 4 5 6 7 Note: your order number should consist of 11 characters. 1. Select code for basic meter arrangement From Table A 20 26 32 38 22 28 34 24 30 36 2. Select code for tube, scales and float From Table B (water) or C (air) 3. Select code for O-ring material S = BUNA N or VITON (standard - from Table A) 1 = EPR (optional) Note: See Tech Data for Pressure and Temp limits. 4. Select code for Tube Retainer Material S = KYNAR (standard) 1 = 316 STAINLESS (optional) 5. 316 S.S. BRASS 6. Select code for flow controller (optional) CAPACITY Connection Model Code 30 scfh-5gph 1/4" NPT inlet 5810 S 30 scfh-5gph 1/4" NPT outlet 5820 T 170 scfh-40gph 1/4" NPT inlet 5850 U 170 scfh-40gph 1/4" NPT outlet 5860 Y 30 scfh-5gph 1/4" NPT inlet 5830 N 30 scfh-5gph 1/4" NPT outlet 5840 P 170 scfh-40gph 1/4" NPT inlet 5870 Q 193 scfh-40gph 1/4" NPT outlet 5880 R NONE Select code for Bezel (optional) 1 = BEZEL (without control valve) 2 = BEZEL (with control valve) X = NONE Note: Available only for 3" Scale Length Meter 7. Select code for Optional Control Valve Location X = No Valve 2 = Inlet Valve 3 = Outlet Valve X 4

TECHNICAL DATA Accuracy 2% of full scale, can be calibrated to an optional 1%. Operating Range 10 to 1. Pipe Connections 1/4-inch female NPT at meter inlet and outlet, at control valve inlet, and at flow controller inlet; horizontal in and horizontal out. Mounting In-line; wall through mounting holes in the back of the frame; flush panel with optional bezel. Scales Scale length is 6 inches, standard calibrations as shown in tables 2 and 3. Pressure and Temperature Limits (Temperature and pressure are interdependent but the following limits must not be exceeded under any conditions.) TUBE PRESS. TEMP. RETAINER O-RINGS (Psig) (F) Kynar Buna N 200 200 Kynar Viton 200 200 316 SS Viton 250 250 Kynar EPR 200 200 316 SS EPR 250 250 Write for TI 500.001, which is a detailed listing of this meter's compatibility with a wide range of fluids. Special Calibration Excluding extra low capacities. Scales calibrated in other than the standard units in Tables B and C are available at extra cost. Calibration for fluids with viscosity other than 1 centistoke is also available at extra cost. Materials of Construction For gas service with constant upstream FRAME 302 stainless and varying downstream pressures, END FITTINGS 316 stainless specify outlet type. Meters with flow TUBE Borosilicate glass controllers are tested and shipped FLOAT See Tables B and C assembled. (Write for TI 570.100) O-RINGS Buna N or Viton with EPR (ethylene propylene rubber) optional - consult factory for other materials TUBE RETAINER Kynar, 316 stainless (optional) LOCK NUT Kynar FLOW INSERT Kynar (Used with high capacity air meters only.) CHECK VALVE 316 stainless POPPET CHECK VALVE Buna N or Viton O-RINGS TUBE SHIELD Polycarbonate VALVE STEM 316 stainless VALVE SEAT 316 stainless STEM ADAPTER 316 stainless STEM RETAINER 316 stainless PIPE PLUG 316 stainless Shipping Weights Meter only, 1 lb. Meter with control valve, 2 lb. Panel mounting bezel, 3 lb. 5 FLOW CONTROLLERS Meters with control valves and W&T Flow Controllers are designed to give reliable flow control, regardless of pressure changes. For liquid service, specify inlet type from Table 5. For gas service with varying upstream and constant downstream pressures, specify inlet type. FLOW CONTROLLER TECHNICAL DATA High Cap. Low Cap. maximum capacity-gas 110 SCFH 30 SCFH maximum capacity-liquid 40 GPH 5 GPH maximum temperature 200 F - Brass (Black Paint Finish) with Buna-N Diaphragm, 250 F - 316 Stainless Steel with TFE Diaphragm Maximum Inlet Pressure 250 psi 250 psi Maximum Pressure Drop 8 psi 8 psi Connection Inlet/Outlet 1/4" NPT 1/4" NPT

TECHNICAL INFORMATION LOW FLOW METER DIMENSIONS ACCESSORIES FLUSH PANEL MOUNTING Plastic bezels for flush mounting are available at nominal cost. They are easy to keep clean and the meter is readily accessible. Wallace & Tiernan Products 1901 West Garden Road Vineland, NJ 08360 856.507.9000 tel 856.507.4125 fax www.wallaceandtiernan.usfilter.com Literature # TI 510.150 UA 9/00 2000 USFilter 6