CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS

Similar documents
SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE

155 CARTRIDGE SINGLE SEAL

225 CARTRIDGE DUAL SEAL

255 Cartridge Dual Seal

250L Cartridge Dual Seal

150 Cartridge Single Seal

250L Dual Cartridge Seal

4410 TwinHydrostatic Gas Seal

4400 TwinHybrid Gas Seal

280 Heavy Duty Cartridge Dual Seal

MECHANICAL SEAL SUPPORT SYSTEMS ASSET OPTIMIZATION FOR INCREASED PRODUCTIVITY

MECHANICAL SEAL SUPPORT SYSTEMS A S S E T O P T I M I Z A T I O N F O R I N C R E A S E D P R O D U C T I V I T Y

Service Manual Air Tech Second Stage

Inverted High Pressure Fluid Filters

442M. Split Mixer Seal Installation Instructions. Equipment Preparation CAUTIONS MECHANICAL SEAL INSTALLATION INSTRUCTIONS. .005" 0,13 mm.

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Service Manual Air Plus Second Stage

GAS SEAL ENGINEERED TO BE EASY

Crispin Valves Operating Guide. Crispin

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

Purging Air From Divider Block Lubrication Systems

KOBOLD DF-MA Flow Transmitter. User Instructions

TECHNICAL INSTRUCTIONS #11 REGULATOR Single Seat - Bronze Trim - Composition Disc

KOBOLD DF-WM Flow Monitor. User Instructions

Upgrade to a new, higher level of reliability and performance. 180 Heavy Duty Cartridge Single Seal

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

KLW4000D Multi-Port Power Pack

Installation Instructions

DAKOTA INSTRUMENTS OPERATING MANUAL ACR ACRYLIC FLOW METERS

COMPANY. Liquid Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:FLOWLIQUIDMETERMAN082516

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

Peristaltic Pump Operating Instructions

INSTRUCTION MANUAL. CR Series A/B

Maintenance Information

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 40E

GRSM17 Pneumatic Center Punch Tool Owner s Manual and Operating Instructions

Super T QR20 INSTRUCTIONS GENERAL RULES

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

FLUID POWER SEALING SOLUTIONS TROUBLESHOOTING GUIDE

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

METERING VALVE 2" STEM GUIDED

INSPECTION & MAINTENANCE BULLETIN ARI 1301/1302 1" Plug Type Angle Valves

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

MAINTENANCE MANUAL DI 16

Jr. T GENERAL. BAM: Bomber Aerospace Material. Special alloy extracted from aerospace material. Ø TRAVEL ±

PAH, PAHT, PAHT G pumps PAH , PAHT and PAHT G Disassembling and assembling

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

105 Commerce Way Westminster, SC Tel: (864) Fax: (864)

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

F-20/G-20 Maintenance

CUSTOM COMBINATION AIR VALVE

GPM Hydraulic Flow Meter User Manual

INSTALLATION INSTRUCTIONS 464, 424 & 324 POST-MIX VALVES

Disassembling and assembling PAH , PAHT and PAHT G

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

WESTATE DIESEL SYSTEMS

G SERIES - E TOUCH MIXER / TAP

Temperature Sensor Series

10A 10F 10B 10E 10A 10D 10B. Mr. T 10C Q R

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

MAINTENANCE PROCEDURE FOR MK17

Maintenance Manual WATER SUMP CONTROL VALVE F532B

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Service Manual. Balanced Piston First Stage

SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

SERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Maintenance Information

Troubleshooting Guide for Pumps ATD ATD ATD5289

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

3M Overhaul Service Kit

MUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

Installation. Installation. 12. System Diagram... 10

3M V-Series Air Control Valves. Maintenance

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Shut-off valves SVA-DH, SVA-DL

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer


Type N550 Snappy Joe Emergency Shutoff Valves

POWER STEERING PUMP REBUILDING SPK101 Read instructions completely before removal & disassembly

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

NILFISK BA 500 Service Manual

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Rev 0 Page 83. Series W91/94 Self-Operating Temperature Regulator. Installation, Operation & Maintenance Instructions

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

Turning Ideas Into Engineered Solutions FILTRATION GROUP

High-Pressure Needle Valves

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

Cylinder and Valve: AirHawk II Air Mask

FOR FUTURE REFERENCE SERIES 93HPS

Transcription:

INSTALLATION INSTRUCTIONS CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS GENERAL The function of the FLOW GUARDIAN Single S50 (Item # 199801 compression fitting, 199804 barb fitting) and SP50 Flowmeter (Item # 199802 compression fitting, 199805 barb fitting) is to accurately control the flow rate of the seal or packing flush fluid. The S50 will control the flow rate of the flush fluid and the SP50 will control the flow rate and pressure of the flush fluid. SPECIFICATIONS Flow Rate Flow rate range to be 2 50 GPH (0,1-3 Liters/min) Pressure Regulating Valve Option (SP50) An integral pressure-regulating valve is provided to set the flush fluid pressure for the mechanical seal or packing. The pressure regulating control knob is located below the pressure gauge and in back of the flow control knob. (Please view Figure 4 page 5 for pressure regulating control knob location) Pressure Gauge The pressure gauge furnished on the FLOW GUARDIAN S50 and SP50 Flowmeters is constructed of 316 SS, oil filled, with 0 145 PSIG and 0 10 bar g compound markings. Material of Construction Flowmeter Tubes: Body of Unit: O-rings: Pressure Gauge: Pressure Regulating Valve: AISI 316 Flow Rate Regulating Valve: AISI 316 Clean-out Plugs: AISI 320 3/8" Tube Fittings (for compression connections) or optional Barb Fittings: AISI 316 Mounting Bracket: AISI 316 Temperature / Pressure Limits Maximum Temperature: 212 F (100 C) Maximum Pressure: 160 PSIG (11 bar g) POLYSULFONE (PSU) POLYOXYMETHYLENE (POM) FLUOROCARBON (FKM) Oil filled with 316SS Stainless Steel Case and Wetted Parts, 1/4" NPT Bronze fitting (Item # 199809) operates on 20-250 AC/DC volts with a switching frequency of 25 Hz AC / 100 Hz DC and the second (Item # 199810) sensor option operates on 10 55 DC volts with a switching frequency of 100 Hz. Optional Low Flow Sensor Two adjustable low flow alarm sensors are available as options. One sensor Qualification Test All Chesterton FLOW GUARDIAN single flowmeters are tested for leak tightness.

INSTALLATION PROCEDURE Typical installation illustrations of the CHESTERTON FLOW GUARDIAN S50/SP50 Single Flowmeters are represented on pages 4 and 5 of these instructions. The S50 and SP50 are utilized for single mechanical seal or packing gland applications. The FLOW GUARDIAN has a mounting plate for simplified installation. The mounting bracket bolt slots accommodate bolt sizes from 1/2" (12 mm) to 7/8" (22 mm). The FLOW GUARDIAN must be mounted vertically to operate accurately. (See Figure 2 page 4, and Figure 5 page 5 for mounting plate dimensions.) Hose Connections for FLOW GUARDIAN S50 Hoses and clamps not included. For compression fitting models use a 3/8" female compression coupling to make connection to all supply and return lines. For barb connector models the hose connections are made by using hoses with a 3/8" (10mm) inside diameter. The hose must be textile reinforced. It must withstand at least 240 PSIG (16 bar g) pressure. Attach the hoses using hose clamps over the hose barb fittings. Leave the hose long enough to prevent kinks and to avoid sharp turns. Long radius connections are preferred. Hose connection instructions are located on the bottom of the mounting plate: 1. IN Clean flush supply feed inlet 2. TO SEAL Clean flush feed to seal (See Figure 2 and 3 page 4 for installation drawing) Hose Connections for FLOW GUARDIAN SP50 Hose connection instructions are located on the bottom of the mounting plate: Hose qualification is the same as S50. For single seal operation a hose jumper is needed to properly install FLOW GUARDIAN SP50 Single Flowmeter. (See Figure 5 page 5) 1. IN Clean flush supply feed inlet 2. TO SEAL Attach end #1 of hose jumper 3. FROM SEAL Attach end #2 of hose jumper 4. OUT Clean flush outlet to mechanical seal flush port or packing lubrication port. Optional Flow Sensor Installation and Adjustment Sensor range capability (0,5 1,25 Liters/min) due to FLOW GUARDIAN body design. Install the alarm sensor in the slot behind the indicating tube that is located in the back of the FLOW GUARDIAN. (See Figure 1 on page 4 and Figure 4 on page 5) 1. The sensor has two lock nuts. Move one of the nuts to the flat end of the sensor. 2. Move the other nut to approximately 1/2"(10 mm) distance from the first nut. 3. Insert the sensor into the sensor slot located at the back of the FLOW GUARDIAN by pivoting it into place at the top opening of the sensor slot (widened). When the sensor is in place, it moves freely up and down in the sensor slot. 4. Locate the sensor in the desired position and tighten the sensor clockwise against the bottom of the sensor slot. To secure the sensor into position tighten the second locking nut by hand until the sensor is secure. If you want to prevent the tampering of the FLOW GUARDIAN and/or make the FLOW GUARDIAN adjustable using a hand tool, remove the black knob. Unscrew the knob lock screw and remove the hand knob. When the knob is removed, screw the delivered M8 lock nut onto the valve. LOW FLOW SENSOR ADJUSTMENT This is done by adjusting the position of the sensor. When the float in the meter tube falls slightly below the midpoint of the sensor, the sensor is activated. To make adjustment to the alarm setting: 1. Adjust the water flow to the alarm value. (Use red arrow sliding indicator as a guide) 2. Move the sensor up until the alarm goes off. 3. Retighten the sensor into position. HIGH FLOW SENSOR ADJUSTMENT This is done by adjusting the position of the sensor. When the float in the meter tube falls slightly below the midpoint of the sensor, the sensor is activated. Repeat the steps above (Low Flow Alarm Adjustment) for improved accuracy of sensor. The FLOW GUARDIAN can have both low flow and high flow sensors. Two sensors are needed to maintain high and low flow conditions. Flow Adjustment (FLOW GUARDIAN S50 without pressurizing valve) (See Figure 1 page 4) To adjust the flow in a FLOW GUARDIAN S50 without the pressurizing valve as follows: 1. Thread the quick cleaning plunger rod into the top of the FLOW GUARDIAN. (Not installed at the factory) 2. Fully open the flow control valve and observe the flow. 3. Use red arrow sliding indicator as a guide for setting flow rate. 4. Push the quick clean plunger down while making flow adjustments until desired flow rate is visible. 5. Adjust the flow control knob until float begins to move slightly at the desired level. 6. To ensure proper flow indication pull quick clean plunger up to the top of the meter tube. 2

INSTALLATION PROCEDURE (CONTINUED) Flow Adjustment (FLOW GUARDIAN SP50 with pressurizing valve) (See Figure 4 page 5) When you use a FLOW GUARDIAN SP50 with a pressurizing valve, you must adjust both the flow rate and pressure as follows: 1. Thread the quick cleaning plunger rod into the top of the FLOW GUARDIAN. 2. Fully open both valves. 3. Push the quick clean plunger down until flow rate is desired. 4. Adjust the flow control valve until float begins to move slightly at desired level. 5. Adjust the pressure control valve that is located behind the flow control valve until the required pressure is set. The adjusting of the pressurizing valve changes the flow rate. Therefore, repeat the steps until both the desired flow rate and the pressure value are reached. SERVICE AND MAINTENANCE Quick Cleaning Over time the meter tube may discolor due to algae, silt, fiber, and other contamination. This may make it difficult to read the flow rate. The FLOW GUARDIAN has a built in quick cleaner plunger. Quick cleaner plunger operates as follows: 1. When you are cleaning, hold the FLOW GUARDIAN firmly. 2. Locate the cleaning plunger rod at the top of the FLOW GUARDIAN. 3. Push the cleaning rod plunger slowly downwards to avoid pressure variations to the seal. Note: If the FLOW GUARDIAN has a flow alarm, the cleaning process may cause a false alarm. 4. Let pressure push the plunger slowly upwards. If required use your hand to raise the plunger back to the top. Metering Components and Valve If quick cleaning with plunger does not resolve problems in flow measuring instruments, problems may be caused by foreign objects or contaminant build up in the metering components. If this occurs the metering components must be disassembled and inspected. Metering component disassembly: 1. Close the water feed to the FLOW GUARDIAN unit. 2. Close the FLOW GUARDIAN flow control valve completely. 3. If the quick cleaner plunger is still in place, remove it. 4. Open and remove the plunger plug using a 14 mm metric wrench. 5. Screw on the quick cleaning rod. Push it halfway into the metering tube. 6. Pull out the quick cleaner and simultaneously push the metering tube out of the meter body using your thumb. 7. Gently lift out the float using a nonmetallic device such as a toothpick. 8. Clean the feed inlet using a cloth wrapped around a toothpick or a small fiber brush. 9. Separate parts should be soaked in soap or mild solvent based solution. Brush them clean using a cloth. 10. Reassemble the metering components in the reverse order. Usually, foreign material in the valve causes a valve problem. When you open the valve and then set the flow back to normal, the foreign material is removed. However, if this does not resolve the problem, you must disassemble the valve to determine the cause of the problem. Valve Disassembly: 1. Close the water feed to the FLOW GUARDIAN unit. 2. The seal must be un-pressurized, shut down the pump. 3. Unscrew the flow control valve assembly using a 22 mm metric wrench. 4. Clean the meter inlet and valve area using a cloth wrapped around a toothpick or fiber brush. 5. If the valve needle O-ring leaks, remove the adjustment knob and screw the needle clockwise through the valve body. Replacement O-ring can be found in the FLOW GUARDIAN flowmeter repair kit. (Item # 199812) 6. Reassemble the valve in the reverse order. O-RING SEALS Remove the broken or worn out O-rings carefully to avoid damage to the sealing surfaces. Best results are obtained by using only fingers or toothpicks. Never use metallic tools. Replacement O-rings can be found in the FLOW GUARDIANrepair kit. When you install new O-rings, remember the following: 1. Do not damage the O-ring when you move it over the threads. A short smooth pipe can be placed over the threads to protect O-ring. 2. Do not leave the O-ring on a spiral or twisted. 3. Before installation, lightly lubricate the new O-rings using silicone lubricant. 4. Use only FKM (Fluorocarbon) O-rings. General Operation and Maintenance The FLOW GUARDIAN does not require regular maintenance. The FLOW GUARDIAN will remain operational for extended periods. Occasional metering tube cleaning is required using the quick cleaner plunger. Only factory authorized spare parts should be used in the FLOW GUARDIAN. Do not replace existing parts with third party components (for example, connectors). Factory O-rings should be used for they are critical components to the FLOW GUARDIAN measurement and operation. Do not leave water in the metering tube during shutdown in cold conditions. Freezing of the water left in the metering tube will break or weaken the tube. Freezing is avoided by purging the meter or fluid and by isolating it from the process. Do not over-tighten the FLOW GUARDIAN components. Proper sealing on the instrument does not require large tightening torque. If a leak develops, replace the O-ring seal (when necessary) rather than tightening the connections more. The recommended tightening torque is 7-10 Nm (5.16-7.37 ft lbs) for all threaded connections. 3

FIGURE 1 - PARTS LIST - S50 6 7 8 1 3 2 KEY 1 Single Flow Meter Tube 2 Flow Control Valve 3 Float 4 Mounting Bracket 5 3/8" Compression Fittings (shown) or Hose Barb Fittings 6 Quick Clean Plunger 7 Pressure Gauge 8 Optional Low Flow Sensor 5 4 FIGURE 2 - DIMENSIONAL REFERENCE - S50 g 72 (2.83 in.) 45 129 (5.07 in.) 122 (4.80 in.) 100 (3.93 in.) 43.5 (1.71 in.) 14.5 (.57 in.) 16 (.62 in.) (.17 in.) 117 {max. 190 with cleaner} (4.60 in.) {max. 7.48 in. with cleaner} 186 (7.32 in.) 2 x Ø 8 (2 x.314 in.) 59.5 (2.34 in.) 18 (.70 in.) 25 (.98 in.) 44 (1.73 in.) max. 144 (5.66 in.) FIGURE 3 - TYPICAL INSTALLATION - S50 in a Single Mechanical Seal Application for control of fluid flush FLUSH SUPPLY INLET FLUSH OR PACKING GLAND INLET INSTALLATION NOTES: 1. RECOMMENDED FLUSH RATE (30 GPH / 113 LPH) (Flush rate can vary depending on product concentration and use of SpiralTrac or bushing) 2. FLUSH PRESSURE TO BE HIGHER THAN STUFFING BOX PRESSURE (15 psi / 1 bar) 4

FIGURE 4 - PARTS LIST - SP50 6 7 8 1 3 2 9 KEY 1 Single Flow Meter Tube 2 Flow Control Valve 3 Float 4 Mounting Bracket 5 3/8" Compression Fittings (shown) or Hose Barb Fittings 6 Quick Clean Plunger 7 Pressure Gauge 8 Optional Low Flow Sensor 9 Pressure Control Valve 5 4 FIGURE 5 - DIMENSIONAL REFERENCE - SP50 72 (2.83 in.) 45 129 (5.07 in.) 122 (4.80 in.) 100 (3.93 in.) 43.5 (1.71 in.) 14.5 (.57 in.) 16 (.62 in.) (.17 in.) HOSE JUMPER 117 {max. 190 with cleaner} (4.60 in.) {max. 7.48 in. with cleaner} 186 (7.32 in.) 18 (.70 in.) 25 (.98 in.) 44 2 x Ø 8 (2 x.314 in.) 59.5 (2.34 in.) (1.73 in.) max. 144 (5.66 in.) FIGURE 6 - TYPICAL INSTALLATION - SP50 in a Single Mechanical Seal Application for control of fluid flush FLUSH SUPPLY INLET HOSE JUMPER connects to (TO SEAL) fitting and (FROM SEAL) fitting (see Figure 5 page 5) FLUSH OR PACKING GLAND INLET INSTALLATION NOTES: 1. RECOMMENDED FLUSH RATE (30 GPH / 113 LPH) (Flush rate can vary depending on product concentration and use of SpiralTrac or bushing) 2. FLUSH PRESSURE TO BE HIGHER THAN STUFFING BOX PRESSURE (15 psi / 1 bar) 5

ISO Certifications available at www.chesterton.com/corporate/iso 860 Salem Street Groveland, MA 01834 USA Telephone: 781-438-7000 Fax: 978-469- 6528 www.chesterton.com A.W.Chesterton Company, 2006. All rights reserved. Registered trademark owned and licensed by A.W.Chesterton Company in USA and other countries. FORM NO. 199812 PRINTED IN USA 10/06