Cisco Nexus 7700 Switches Environment

Similar documents
Power and Cooling. Chassis Power System

Features and Benefits

Preparing the Site. Information About the Site Requirements CHAPTER

596 Rectifier Retrofit

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

Est FlexiPower Mini UPS FPX Mini kVA

Installing the Switch Chassis

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

VaultFlex Battery Enclosures. from EnerSys and Purcell Systems. Two industry leaders team up to provide new synergy, efficiency and flexibility

Technical Specifications

Installing Power Components

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Cabinet and Rack Installation

Installing the ONS M6 Shelf

Cabinet and Rack Installation

5067 Mini BDFB / BDCBB

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

Cabinet and Rack Installation

DPA UPScale RI kw The modular UPS for customized solutions

Racks & Integrated Cabinets. Knürr IT Special Catalog Networks and Data Centers

Cabinet and Rack Installation

NetSure. 211 Series DC Power System

CENTURY YUASA - STANDBY OVERVIEW

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Electric buses Solutions portfolio

INTELEPOWER CX COMMUNICATIONS SYSTEMS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

3 Uninterruptible Power Systems

Uninterruptible Power Supplies

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

INTELEPOWER CXS SWITCHING SYSTEMS

Cisco Power Calculator -Power Results

TECHNICAL DATA MINICUBE A SMART SOLUTION, POWERFUL IN ITS SIMPLICITY

Cisco ASR 1002 Router Overview and Installation

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Dell Networking W-7200 Series mobility controllers

3 Uninterruptible Power Systems

UPS Multi Power 1-28 x 42 kw up to 1MW

ABB UPS 3. November 2014

Installing the Air Flow Regulator

Secondary DC Distribution

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

Application Note. Best Solutions for Managing High-Current Power Distribution

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Power+ CLASSIC. 20/30 kva, 3x208 Vac

E-Series and EF-Series Systems

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Liebert. APS UPS 5-20 kva Flexible, efficient scalable UPS for room or row-based applications

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

MGE Galaxy 5500 Marine

GT-Series GlobalFrame Gen 2 Cabinet System

Open Rack Hardware v0.6

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

TECHNICAL WHITE PAPER

MORNINGSTAR PRODUCT TRAINING

LV5 + Solar Power Station

Fuse / Circuit Breaker Panels

Cisco Nexus 9396PX Switch Site Preparation and Hardware Installation Guide

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Solar Microgrid Integrates Solar PV, Energy Storage, Smart Grid Functionality and Advanced Vehicle-to-Grid Capabilities

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Up to 4 x Temperature Monitoring Probes with Control Cable (1 Included) User set point control, display for Rack Face Temperature

3 Uninterruptible Power Systems

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

One-Stop Service: Monitoring and Managing.

Smart-UPS with APC SmartConnect Maintain business certainty with intelligent network power protection

ABB central inverters ULTRA-750/1100/ kW to 1560kW

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

PowerValue 11/31 T kva

Veefil 50kW fast charger:

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

SITESTAR ELECTRONICS CABINET DESCRIPTION

2 Uninterruptible Power Systems

Nuclear Industry Applications

Transcription:

Data Sheet Cisco Nexus 7700 Switches Environment Data Sheet Product Overview The Cisco Nexus 7700 platform is the latest extension to the modular Cisco Nexus 7000 Series Switches. Capable of 83 terabits per second (Tbps) of overall switching capacity, the Cisco Nexus 7700 platform switches deliver the highest-capacity 10, 40, and 100 Gigabit Ethernet ports in the industry: up to 768 wire-rate 10-Gbps ports, 384 40-Gbps ports, and 192 100-Gbps ports. The Cisco Nexus 7700 platform switches have operation and feature consistency with the existing Cisco Nexus 7000 Series Switches, using the same system architecture, application-specific integrated circuit (ASIC) technology, and proven Cisco NX-OS Software versions. Designed to meet the requirements of the most mission-critical data centers, these switches deliver outstanding availability and scalability and a comprehensive NX-OS feature set that includes real-time system upgrades with exceptional manageability and serviceability. The Cisco Nexus 7700 chassis (Figures 1, 2, 3, and 4) incorporate significant enhancements in design, power, airflow, cooling, and cabling. All four chassis have true front-to-back airflow, making them excellent solutions for hot-aisle and cold-aisle deployments. The power supplies, I/O modules, and supervisor modules are accessible from the front of the chassis, and the fabric modules and fan trays are accessible from the back of the chassis. In addition, the Cisco Nexus 7000 Series has many power saving enhancements such as temperature sensors, variable-speed fans, and high-efficiency power supplies that reduce the total cost of ownership (TCO) for customers. Figure 1. Cisco Nexus 7700 2-Slot Switch Chassis Figure 2. Cisco Nexus 7700 6-Slot Switch Chassis 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 8

Figure 3. Cisco Nexus 7700 10-Slot Switch Chassis Figure 4. Cisco Nexus 7700 18-Slot Switch Chassis 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 2 of 8

Physical Specifications The Cisco Nexus 7700 2-Slot Switch chassis has one supervisor slot, one I/O module slot, two power supply bays, dual-side integrated cable management, and an optional front door with an air filter on the front of the chassis. There is an integrated fan tray with three built-in fans and no fabric module slots. The Cisco Nexus 7700 6-Slot Switch chassis has two supervisor slots, four I/O module slots, dual-side integrated cable management, four power supply bays, and an optional front door with an air filter on the front of the chassis. On the back, it has three system fan trays and six fabric slots behind the fan trays. The Cisco Nexus 7700 10-Slot Switch chassis has two supervisor slots, eight I/O module slots, dual-side integrated cable management, eight power supply bays, and an optional front door with an air filter on the front of the chassis. On the back, it has three system fan trays and six fabric slots behind the fan trays. The Cisco Nexus 7700 18-Slot Switch chassis has two supervisor module slots, 16 I/O module slots, dual-side integrated cable management, 16 power supply bays, and an optional dual-hinged protective front door with an air filter at the front of the chassis. On the back are three system fan trays and six fabric module slots behind the fan trays. Table 1 summarizes the physical features of the chassis. Table 1. Item Physical Specifications Cisco Nexus 7700 2-Slot Switch Cisco Nexus 7700 6-Slot Switch Cisco Nexus 7700 10-Slot Switch Cisco Nexus 7700 18-Slot Switch Dimensions (H x W x D) 5.15 x 17.3 x 29.1 in. (13.08 x 43.9 x 73.9 cm) 15.6 x 17.3 x 32 in. (39.62 x 43.9 x 81.3 cm) 24.35 x 17.3 x 34 in. (61.85 x 43.9 x 86.4 cm) 42.25 x 17.3 x 35 in. (111.49 x 43.9 x 88.9 cm) Chassis depth with cable management and doors 35.1 in. (89.15 cm) 38 in. (96.52 cm) 40 in. (101.6 cm) 41 in. (104.1 cm) Rack units (RU) 3RU 9RU 14RU 26RU Weight Chassis only 37.5 lb (17 kg) 145 lb (66 kg) 160 lb (72 kg) 300 lb (136 kg) Fully configured 81.7 lb (37 kg) 325 lb (148 kg) 438 lb (199 kg) 900 lb (408 kg) Module orientation Supervisor and I/O modules: Horizontal No fabric cards Supervisor and I/O modules: Horizontal Fabric cards (at the back): Vertical Airflow Cable management Air filter Doors Front to back Designed for hot-aisle and cold-aisle deployments Integrated dual-side cable management for flexible cabling deployments Optional door air filter Optional lockable front module doors and air filter System LEDs None 5 system LEDs that summarize the device status: LED 1: Power supplies LED 2: Fans LED 3: Supervisors LED 4: Fabric modules LED 5: I/O modules Each LED is green if the status is normal, and amber otherwise. 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 3 of 8

Power The Cisco Nexus 7700 2-Slot chassis has two power supply bays, the Cisco Nexus 7700 6-Slot chassis has 4 four power supply bays, the Cisco Nexus 7700 10-Slot chassis has eight power supply bays, and the Cisco Nexus 7700 18-Slot chassis has 16 power supply bays that can hold 3.0-kilowatt (kw) AC, 3.0-kW DC or 3.5-kW HVAC/HVDC power supplies. The smaller power supply configuration provides more flexibility and more detailed control in power provisioning. The 2, 4, 8, and 16 power supply bays for the 6-slot, 10-slot, and 18-slot chassis respectively are designed for redundancy and future growth. Each 3000-watt (W) power supply has one universal (100 to 240 volt [V]) input that can be connected to one AC source using an AC power cord with a C19 connector. Two versions are available: one for international markets, with an IEC 60309 AC plug; and one for U.S. markets, with a NEMA L6-30 AC plug. The 3500W power supply uses an Anderson 2006G Saf-D-Grid connector capable of accepting up to 400V AC and 400V DC input. Table 2 shows the power output provided by one Cisco Nexus 7700 3.0-kW AC power supply module. Table 2. AC Power Supply Output Power Supply Input Output Single input 220V 3000W 110V 1500W Table 3 shows the power output provided by one Cisco Nexus 7700 3.0-kW DC power supply module. Table 3. DC Power Supply Output Power Supply Input Input Output Single input -48V 1500W Dual input -48V 3000W Table 4 shows the power output provided by one Cisco Nexus 7700 3.5-kW DC Power Supply Module. Table 4. Power Supply Output Input Type Input Voltage Output AC input 100 to 120 VAC 1500W 200 to 210 VAC 3100W 215 to 240 VAC and 277 VAC 3500W DC input 200 to 215 VDC 3100W 220 to 380 VDC 3500W Cisco Nexus 7700 power supplies are more than 90 percent efficient, so less power is dissipated as heat, and more power is available for the system to use than with typical power supplies. The high-efficiency 3-kW power supplies allow smaller power configuration and provide flexible power provisioning. The Cisco Nexus 7700 systems can operate in four user-configurable power redundancy modes, listed in Table 5. The power redundancy modes are designed to determine the optimum power for the combination of power supplies installed, helping ensure system availability. 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 8

Table 5. Power Redundancy Modes Redundancy Mode Combined Power supply redundancy (N+1 redundancy) Input source redundancy (grid redundancy) Power supply and input source (full) redundancy This mode does not provide redundancy. The power available to the system is the sum of power outputs of all power supplies in the chassis. This mode guards against the failure of one of the power supplies. The redundant power available to the system is the sum of all power outputs less one of the maximum-rated power supplies. This mode guards against failure of one power supply or input circuit (grid), with at least half the power supplies connected to a different independent AC or DC feed. The power available to the system is the minimum power from both the grids. If one of the power supplies fails, the operational power redundancy mode changes to combined mode (supported only with 220V). This mode guards against failure of one power supply or one grid. The power available is the minimum power from the input source and power supply redundancy. If one of the power supplies fails, the operational power redundancy mode changes to the power supply redundancy (N+1) mode. The NX-OS operating system requires a minimum of 565W to run the 2-slot system (one supervisor module and one fan tray), a minimum of 1730W to run the 6-slot system (three fan trays, six fabric modules, and two supervisor modules), a minimum of 3230W to run the 10-slot system (three fan trays, six fabric modules, and two supervisor modules), and a minimum of 5030W to run the 18-slot system (three fan trays, six fabric modules, and two supervisor modules). If the power available from the power supplies is more than the minimum, the additional power is used to activate the I/O modules. If there is not enough power to activate the I/O modules, the I/O modules are kept in a power-denied state. After more power is provisioned, the user must turn on power to the I/O modules manually to activate them. Under typical operating conditions, the system consumes significantly less power than the maximum values. NX- OS uses the maximum values to reserve sufficient power for the I/O modules. The maximum power values are determined under the worst-case conditions. The typical power rating is the value that is commonly seen in a typical facility environment. Both the maximum and typical power ratings for the Cisco Nexus 7700 system and modules can be found using the Cisco Power Calculator (CPC) Tool, at http://tools.cisco.com/cpc/ds.cpc. Climatic Environment Table 6 summarizes the climatic environment for the Cisco Nexus 7700 2-Slot, 6-Slot, 10-Slot, and 18-Slot chassis. Table 6. Item Climatic Environment Cisco Nexus 7700 2-Slot Switch Cisco Nexus 7700 6-Slot Switch Cisco Nexus 7700 10-Slot Switch Cisco Nexus 7700 18-Slot Switch Floor loading 24 lb per sq ft 92 lb per sq ft 122 lb per sq ft 230 lb per sq ft Seismic Zone 4 per GR63 Heat dissipation Maximum 6650 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration) Maximum 26,380 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration) Maximum 52,500 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration) Maximum 96,160 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration) Temperature Operating: 32 to 104 F (0 to 40 C) Δ Short term: 23 to 131 F ( 5 to 55 C) *Δǂ Nonoperating: 40 to 158 F ( 40 to 70 C) *ǂ Note: Chassis external thermal requirements are defined in the GR-63-CORE Network Equipment Building Standards (NEBS) specification published by Telcordia Technologies in Section 4.1.2, Operating Temperature and Humidity Criteria. * 131 F (55 C) and 25% relative humidity applies for equipment shelves that fill less than half the frame (length). Δ Maximum allowable altitude of operation is 6000 ft. ǂ Agency testing is in progress. 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 8

Item Humidity Relative humidity (nonoperating): 5 to 95%, noncondensing Relative humidity (operating): 5 to 90%, noncondensing Note: An ambient relative humidity between 45 and 50% is suggested to reduce corrosive problems, to provide an operating-time buffer in the event of failures, and to reduce interference from static discharges. Altitude 500 to 13,123 ft; agency certified 0 to 6500 ft Storage altitude: 1000 to 30,000 ft Operating vibration GR63 Section 5.4.2 ETS 300 019-1-3 Class 3.1 Section 5.5 Airflow and Cooling The 2-slot chassis is cooled by one fan tray consisting of three redundant variable-speed fans that cool the supervisor module and the I/O module. The cooling system for the 6-slot, 10-slot, and 18-slot chassis consists of three redundant system fan trays that deliver cooling for the I/O and supervisor modules as well as for the fabric modules. Each system fan tray is composed of multiple independent fans. The fan trays can be removed from the rear of the chassis, allowing continuous system operation during maintenance. Each fan module incorporates fan redundancy and fan-controller redundancy to deliver resilience for either a fan or controller failure. Table 7 summarizes the airflow and cooling features of the Cisco Nexus 7700 chassis. Table 7. Feature Airflow Fan trays Cisco Nexus 7700 Chassis Airflow and Cooling Features Air flows front to back. Air enters through the perforations in the I/O and supervisor modules at the front of the chassis and exits at the rear of the chassis, making the Cisco Nexus 7700 chassis excellent for hot-aisle and cold-aisle designs. Cisco Nexus 7700 2-Slot Switch: 1 removable fan tray with three redundant variable-speed fans Cisco Nexus 7700 6-Slot, 10-Slot, and 18-Slot Switches: 3 removable fan trays with three variable-speed fans each Fan trays removable from the rear Variable fan speeds Self-healing mechanism Fan redundancy Air filter All fan trays can be removed from the rear. Hence, there is no obstruction from the I/O module cabling on the front. This arrangement enables continuous system operation during maintenance. Current fans have 256 speed levels. The fan speed changes based on the type of I/O module (and supervisor), the inlet temperature reading on the supervisor, and the presence or absence of an air filter. Power consumption and noise emission by fans is optimized. The software tracks the temperature of the most critical components on the I/O modules and the supervisors. If the recorded temperature is higher than a certain system-defined threshold, the fan speed automatically increases and stays at that speed until the temperature falls below the threshold. All fan trays are redundant and hot swappable except the fan tray on the Cisco 7700 2-Slot Switch, which has only one fan tray. When one fan is removed, the speed of the remaining two fans is increased, and the system will shut down after 72 hours. The user will be informed hourly by syslog. When more than one of the fans is removed, the speed of the remaining fan trays increases to the maximum, and the system will shut down in 2 minutes. The air filter filters dust and keeps the chassis interior clean. Use of an air filter increases the fan speed; higher fan speeds result in higher levels of noise. Cabling and Cabinet The cable management system for the Cisco Nexus 7700 2-Slot, 6-Slot, 10-Slot, and 18-Slot chassis is located on both sides of the chassis and aligned with the module slots. The Cisco Nexus 7700 2-Slot, 6-Slot, 10-Slot, and 18-Slot chassis should be installed in either a standard four-post rack or a four-post cabinet that meets the depth, total equipment weight, and network cabling requirements. The Cisco Nexus 7700 2-Slot and 6-Slot chassis can be installed in a standard two-post rack as well. 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 8

Regulatory Compliance The Cisco Nexus 7700 2-Slot, 6-Slot, 10-Slot, and 18-Slot chassis are designed to meet regulator emissions and immunity requirements when tested with existing and future cards and power supplies, as summarized in Table 8. Table 8. Specification Emissions and Immunity Specifications Regulatory compliance EMC compliance FCC Part 15 (CFR 47) (USA) Class A ICES-003 (Canada) Class A EN55022 (Europe) Class A CISPR22 (International) Class A AS/NZS CISPR22 (Australia and New Zealand) Class A VCCI (Japan) Class A KN22 (Korea) Class A CNS13438 (Taiwan) Class A CISPR24 EN55024 EN50082-1 EN61000-3-2 EN61000-3-3 EN61000-6-1 EN300 386 EN61000-4-5 Table 9 summarizes NEBS compliance. Table 9. Specification NEBS Specifications Environmental standards NEBS criteria levels * SR-3580 NEBS Level 3 (GR-63-CORE and GR-1089-CORE) Verizon NEBS compliance * Telecommunications Carrier Group (TCG) Checklist Century Link NEBS requirements * Telecommunications Carrier Group (TCG) Checklist ATT NEBS requirements * ATT TP76200 level 3 and TCG Checklist ETSI * ETSI 300 019-1-1, Class 1.2 Storage ETSI 300 019-1-2, Class 2.3 Transportation ETSI 300 019-1-3, Class 3.2 Stationary Use * Validation in Progress The Cisco Nexus 7700 platform switches are designed to meet regulator safety requirements when tested with existing and future cards and power supplies, as summarized in Table 10. Table 10. Specification Safety Specifications Safety UL/CSA/IEC/EN 60950-1 AS/NZS 60950 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 8

Service and Support Cisco offers a wide range of services to help accelerate your success in deploying and optimizing the Cisco Nexus 7700 platform in your data center. Our innovative services are delivered through a unique combination of people, processes, tools, and partners and are focused on helping you increase operating efficiency and improve your data center network. Cisco Advanced Services use an architecture-led approach to help you align your data center infrastructure with your business goals and provide long-term value. Cisco Smart Net Total Care Service helps you resolve mission-critical problems with direct access at any time to Cisco network experts and award-winning resources. With this service, you can take advantage of the Cisco Smart Call Home service capability, which offers proactive diagnostics and real-time alerts for your Cisco Nexus 7700 platform switches. Spanning the entire network lifecycle, Cisco services help increase investment protection, optimize network operations, provide migration support, and strengthen your IT expertise. For more information about Cisco Data Center Services, visit http://www.cisco.com/go/dcservices. Cisco Capital Financing to Help You Achieve Your Objectives Cisco Capital can help you acquire the technology you need to achieve your objectives and stay competitive. We can help you reduce CapEx. Accelerate your growth. Optimize your investment dollars and ROI. Cisco Capital financing gives you flexibility in acquiring hardware, software, services, and complementary third-party equipment. And there s just one predictable payment. Cisco Capital is available in more than 100 countries. Learn more. For More Information For more information about the Cisco Nexus 7700 platform, visit the product homepage at http://www.cisco.com/go/nexus7000 or contact your local account representative. Printed in USA C78-728736-08 04/16 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 8