TIMKEN SNT SPLIT PLUMMER BLOCKS

Similar documents
Split Pillow Block Housings & Accessories

UC-SERIES TIMKEN BALL BEARING HOUSED UNITS

SPLIT CYLINDRICAL ROLLER BEARINGS

Spherical Roller Bearings

SNN SPLIT PLUMMER BLOCKS

Split pillow blocks SDAF series including the extended range (inch dimensions)

Split plummer block housings SED 30, 31, 32 and 39 series

FKL Bearings in Vibrating Screens

Instruction Manual for PTI Split Block Bearing Units For SAF, SDAF, SN, SNG, SNHF, S3000K & SD Series Housings

Features And Benefits.IMPERIAL... B14-2.IMPERIAL-IP... B14-4.IMPERIAL-HD... B14-6 ISAF-HYD... B14-10.ISN / ISNX-HYD... B14-12

Split plummer block housings SE 2, 3, 5 and 6 series

Split plummer block housings SNLN 30 series

Drawn cup needle roller bearings

Flanged housings FNL series

CONVEYOR COMPONENTS: Baldor Dodge ISAF HYD & ISNX Bearings for Conveyor Pulleys

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN THRUST AND PLAIN BEARINGS CATALOG

A SPHERICAL REVOLUTION

TECHNICAL INFORMATION

Publication BCRKB.Rev00EN. RKB Europe SA 2018/07

DODGE USN 500 and 600 Series Adapter Mount & 200 and 300 Series Direct Mount Plummer Blocks

Split plummer block housings SONL series

Bearings. Rolling-contact Bearings

TOUGH AND LONG LIFE (TL) SERIES SPHERICAL ROLLER BEARINGS

DODGE USAF 500 SERIES Pillow Blocks

THE REX DESIGN REPLACEABLE BEARING

Cylindrical roller bearings

INSTRUCTION MANUAL FOR DODGE SAF-XT & SAFS Pillow Blocks All Sizes 1 15 / 16 " through 10 1 / 2 " 2 and 4 Bolt Base

Instruction Manual for HSPA Take-Up Units

10 Thrust ball bearings

Track Rollers/ Cam Followers

Dodge ISN mounted spherical roller bearings

4 Self aligning ball bearings

DODGE USAF 500 SERIES Pillow Blocks

TIMKEN TYPE E TAPERED ROLLER BEARING HOUSED UNITS

TECHNICAL INFORMATION

TIMKEN DEEP GROOVE BALL BEARINGS

Vibrating Mechanism Bearings

TIMKEN HOUSED UNIT CATALOG INDEX

FEATURES/BENEFITS. Type E-Xtra DODGE Type E One Bearing, One Seal For Dusty or Damp Environments

Heavy Duty Pillow Block

THE REX DESIGN. RUGGED HOUSING Standard material cast iron. Steel or ductile iron available on request.

Sealed SKF spherical roller bearings for demanding environments

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG

Set screw mounted ball bearings

CONTENTS. DODGE Plummer Blocks

Ch# 11. Rolling Contact Bearings 28/06/1438. Rolling Contact Bearings. Bearing specialist consider matters such as

Split Spherical Roller Bearings

SPECIFICATIONS. Housing

CONTENTS. Speciality Tapered Products

Housings for paper machines SBFN, SBPN and SDM series

CONTENTS. IMPERIAL - IP, ISAF and ISN

FUNCTION OF A BEARING

DODGE USAF 200/300 Direct Mount Pillow Block Bearings

PRODUCT CATALOG BEARING HOUSINGS In-house Manufacturing.

Double-row ball bearings

Forming section. Bearing arrangements...

SEALED SPHERICAL ROLLER BEARING

PLUMMER BLOCK HOUSINGS

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION

Axial-radial cylindrical roller bearings

Bearing Fundamentals. Timken Training

Q&A Session for Advanced Linear Bearings and Guides 201 : Troubleshooting for Design Engineers

14 Track runner bearings

Special Duty, Hinged Cap... B Special Duty, Hinged Cap & Traction Wheel... B Pillow Blocks... B6--56

CONTENTS. Setscrew Ball Bearings

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS

Bearings for Fans. Bearing arrangements for fans

TIMKEN HOUSED UNIT CATALOG INDEX

FEATURES/BENEFITS. Setscrew Ball Bearings. DODGE End Covers

DESIGN AND SELECTION OF BEARINGS AND HOUSINGS USED IN MATERIAL HANDLING APPLICATIONS

TYPE OF MOUNTED BEARING. LER - Metal Labyrinth Ends Open. Pillow Block. (Inch Dimensions) 2 = 2 SS - Split P4B - 4 Bolt Base Pillow

SKF Cooper split bearings

Cylindrical roller bearings for large electric motors

Timken Spherical Plain Bearings. An industry standard throughout the world.

bearings (metric series)

SKF FAG Timken NSK NTN

Premium Type E Mounted Roller Bearing

SNL plummer block housings. solve the housing problems

15E INSOCOAT bearings

Timken Solutions for the Coal Power Generation Industry Reliable Technology, Dependable Power

Linear Bushings and Shafts Inch Series

DryLin R Linear Plain Bearings, Fast and Quiet

ILLUSTRATION FOR SNT-H SERIES

3. BEARING ARRANGEMENT DESIGN

Wind Energy Solutions

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet

EPT Mounted Bearing Technical Support. Phone: FAX: Mounted Bearing Application Engineering

Rexnord 6000 Series Features SHURloK adapter mount with:

DryLin R Linear Plain Bearings, Fast and Quiet

SKF Slide 1 SKF Mining, Mineral Processing & Cement

VIBRATING SCREEN APPLICATIONS EF800 ULTAGE. Spherical roller bearings. With You

Cam Follower Bearings

Classification and Characteristics of Rolling Bearings

INSOCOAT bearing designs INSOCOAT bearings with coated outer ring INSOCOAT bearings with coated inner ring

SD Plummer Block Housings

PUMP BEARING TRAINING

Mainshaft Bearings: Bearing Arrangements, Damage Modes and Technology Advancements. Presented by Richard Brooks AWEA O&M Conference 2017

Bearing Reference CONTENTS. Guide S-2000

Chapter 11 Rolling Contact Bearings

Transcription:

TIMKEN SNT SPLIT PLUMMER BLOCKS TIMKEN SNT SPLIT PLUMMER BLOCKS 1

TABLE OF CONTENTS INTRODUCTION... 3 TIMKEN SNT SPLIT PLUMMER BLOCKS...4 SEAL OPTIONS AND DESCRIPTIONS...6 SEAL SELECTION AND CONFIGURATION EXAMPLE......................................... 7 SNT NOMENCLATURE: 0-0 AND 0-0 SERIES; 00 AND 3100 SERIES...8 HOUSING STRENGTH...10 RADIAL INTERNAL CLEARANCE...11 SHAFT LENGTH GUIDELINES...13 TWO-BOLT SNT HOUSINGS FOR TAPERED BORE BEARINGS 0/0 SERIES................ 14 FOUR-BOLT FSNT HOUSINGS FOR TAPERED BORE BEARINGS 0/0 SERIES... TWO-BOLT SNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS 0/0 SERIES...22 FOUR-BOLT FSNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS 0/0 SERIES... FOUR-BOLT SNTD HOUSINGS FOR TAPERED BORE BEARINGS 00 AND 3100 SERIES... FOUR-BOLT SNTD HOUSINGS FOR CYLINDRICAL BORE BEARINGS 00 AND 3100 SERIES...36 SNTN HOUSINGS FOR TAPERED BORE BEARINGS 00 LIGHT SERIES...38 SNTN HOUSINGS FOR CYLINDRICAL BORE BEARINGS 00 LIGHT SERIES...40 2 TIMKEN SNT SPLIT PLUMMER BLOCKS

A SINGLE SOLUTION HOUSED IN STRENGTH Stronger outside. Smarter inside. Accelerate your efficiency with Timken SNT Plummer Blocks that keep lubrication in and contamination out. With a split-design cast iron or ductile iron housing outside and Timken High-Performance Spherical Roller Bearing inside you ll put an integrated bearing solution of the highest integrity to work. Engineered Housings: No matter the size, our durable housings are engineered to perform. The large sizes (00 and 3100 series) come standard in ductile iron for your toughest applications. Timken Spherical Roller Bearings: Gain longer bearing life through premium performance from increased load-carrying capacity and cooler running temperatures. Four Seal Options: Choose from double-lip, labyrinth, V-ring or taconite designs. Effective Lubrication: The lubrication system features a centermounted grease fitting matched to the bearing lube ring and holes, along with options for other grease fitting locations. Flexible Configurations: With many options to choose from, there s a Timken SNT split plummer block solution to meet all your needs. Depending on your accessories, a single housing can be utilized for a variety of bearings based on capacity needs, in fixed or float positions, and open or closed with end covers. TIMKEN SNT SPLIT PLUMMER BLOCKS 3

TIMKEN SNT SPLIT PLUMMER BLOCKS STRONGER OUTSIDE Timken engineered split plummer block solutions deliver performance, productivity and efficiency. SPLIT-BLOCK HOUSINGS Provide proper support with precision-fit matched and serialized cap-and-base that are dowel-pin aligned. Simplifies installation of heavy housings. Convenient pry-tool slots for easy cap removal, speedy bearing inspection and replacement. SEAL OPTIONS Help keep interior contact surfaces debris-free and properly lubricated with strong and effective seals. Timken double-lip, labyrinth, V-ring and taconite seal options increase bearing life and improve uptime. OPTIONAL END COVERS Avoid damage to bearing and housing with easy to install end covers. TAPERED ADAPTER OR STRAIGHT BORE MOUNTING Secure each bearing onto the shaft. STANDARD METRIC MOUNTING DIMENSIONS Easy installation with industry standard dimensions for bolt holes, center height and shaft diameter. Conforms to ISO 113:1999. CAST IRON AND DUCTILE IRON Timken SNT split plummer block housings are produced with highquality cast iron or ductile iron. Cast iron (gray cast iron) is the standard material for the 0 0 and 0 0 series housings. Cast iron has good wear resistance, high vibration absorption (damping) properties, good thermal conductivity and is suitable for many industrial applications. Ductile iron (spheroidal or nodular graphite cast iron) is the standard material for the 00 and 3100 series. Ductile iron, also known as SGI, has more impact and fatigue resistance than cast iron due to the graphite nodules. Ductile iron housings can support loads higher than gray cast iron. LOCATING RINGS Provide flexibility to fix or float the bearing. HOUSING MATERIALS Rugged cast iron and ductile iron are well-suited for harsh industrial applications. The 0 0 and 0 0 series are furnished in cast iron. The large 00 and 3100 series come standard in ductile iron. LUBRICATION Enhance the performance of our split plummer block solutions with Timken grease and single-point lubricators. Learn more at http://www.timken.com/en-us/products/lubrication. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 4 TIMKEN SNT SPLIT PLUMMER BLOCKS

TIMKEN SPHERICAL ROLLER BEARINGS SMARTER INSIDE Timken Spherical Roller Bearings are engineered to give you more of what you need. LOWER OPERATING TEMPERATURES Rollers are guided by cage pockets not a center guide ring eliminating a friction point and resulting in 4 10% less rotational torque and 5º C lower operating temperatures.* TOUGHER PROTECTION Hardened steel cages deliver greater fatigue strength, increased wear resistance and tougher protection against shock and acceleration. OPTIMIZED UPTIME Unique slots in the cage face improve oil flow and purge more contaminants from the bearing to help extend equipment uptime. MINIMIZED WEAR Improved profiles reduce internal stresses and optimize load distribution to minimize wear. IMPROVED LUBE FILM Enhanced surface finishes avoid metal-to-metal contact to reduce friction and result in improved lube film. HIGHER LOADS Longer rollers result in 4 8% higher load ratings or 14 29% longer predicted bearing life. Higher load ratings enable you to carry heavier loads. Brass cages are available in all sizes; ready when you need extra strength and durability in the most unrelenting conditions, including extreme shock and vibration, high acceleration forces, and minimal lubrication. Typically, SNT housings use spherical roller bearings with C3 or C0 clearance. Timken offers a wide variety of clearances to meet your application needs. *All results are from head-to-head testing against multiple competitors. AVERAGE BEARING O.D. TEMPERATURE 100 C 212 F 95 C 3 F 90 C 194 F 85 C 5 F C 176 F Competitor C 94 C (1.2 F) Target L10 Calculated Life Competitor A 91 C (195.8 F) Competitor B 89 C (192.2 F) Timken 86 C (6.8 F) Increase your operational efficiencies and extend maintenance intervals. Starting now. Visit Timken.com/spherical to find out more. 0 0.5 1 1.5 2 2.5 LIFE RATIO Tested 22212 at 20 rpm with a load ~ 25% of the dynamic capacity. TIMKEN SNT SPLIT PLUMMER BLOCKS 5

SEAL OPTIONS: 0 0 AND 0 0 SERIES DOUBLE-LIP (TSNG) V-RING (VR) LABYRINTH (LO) TACONITE (TA) END COVERS (EC) SEAL OPTIONS: 00 AND 3100 SERIES LABYRINTH (LO) TACONITE (TA) END COVERS (EC) SEAL DESCRIPTIONS Timken SNT split plummer blocks are available with multiple sealing options. Each seal type incorporates specific features to meet your application needs. The table on the following page compares the various features of each seal type. DOUBLE-LIP SEALS (TSNG) Double-lip seals are the most common seal design used with SNT split plummer blocks. These are general all-purpose elastomer seals that can protect in moderately contaminated environments. The seal is split into two 0 degree halves for easy installation. The seal element runs against the shaft surface and should be used in grease lubricated blocks. Contact your Timken engineer for double-lip seal availability when using cylindrical bore housings. V-RING SEALS (VR) V-ring seals are a deflector type seal. They are made up of an elastomer V-ring seal element that rotates with the shaft and runs against the axial surface of a washer-type component that is retained in the block housing. As the V-ring element is a stretch fit onto the shaft, a rougher shaft surface is acceptable. This seal performs well in moderately contaminated environments with fine particulate. LABYRINTH SEALS (LO) Labyrinth seals are made up of a single metal ring component that interconnects with the grooves in the housing to form a labyrinth gap. The inside diameter of the metal ring contains an O-ring that creates an interference fit with the shaft so that the ring will rotate with the shaft. Labyrinth seals can be used on high-speed applications and in moderately contaminated environments. TACONITE SEALS (TA) Taconite seals are a combination of both a labyrinth seal and V-ring seal. The labyrinth seal is made up of two separate metal ring components, inner and outer, that have interconnecting grooves that form a labyrinth gap. The outer metal ring component contains an O-ring on its outside diameter that provides an interference fit to the groove in the housing. The inside diameter of the inner metal ring component contains an O-ring that creates an interference fit with the shaft so that the ring will rotate with the shaft. This seal performs well in highly contaminated environments such as those seen in mining operations. END COVERS (EC) In some applications, the shaft end is designed to terminate inside the pillow block. For this design, positive fitting end-cover inserts are available to help seal out contaminants and retain lubricants providing additional protection to the bearing. 6 TIMKEN SNT SPLIT PLUMMER BLOCKS

SEAL SELECTION Seal Selection Double-Lip (TSNG) V-Ring (VR) Labyrinth (LO) Taconite (TA) Material NBR NBR rubber + mild steel plate Steel + NBR O-ring Steel + NBR O-ring and V-ring Temperature -40 to 100 C (-40 to 212 F) -40 to 100 C (-40 to 212 F) -40 to 1 C (-40 to 8 F) -40 to 100 C (-40 to 212 F) Maximum linear speed 8 m/s ( f/s) 7 m/s (23 f/s) Same as bearing 7 m/s (23 f/s) Grease relubrication (1) Excellent Excellent Good Good Low friction Good Good Excellent Good Resists dust/fine particles Excellent Excellent Good Excellent Resists coarse particles Good Fair Excellent Good Resists water Good Good Fair Good Misalignment Shaft dia. 100 mm Misalignment Shaft dia. > 100 mm (1) If an application requires oil lubrication, please contact your Timken engineer. 1 1.5 0.3 0.3 0.5 1 0.3 0.3 FLEXIBLE CONFIGURATIONS With many options to choose from, there s a Timken SNT split plummer block to meet all your needs. Depending on the accessories you choose, a single housing can be used with multiple bearings, in fixed or float positions, and open or closed end covers. Flexible configurations deliver the single solution to meet all of your needs. Note: A special coating system is also available for marine applications and other highly corrosive environments. Simply add suffix /127 to the housing part number when ordering. TAPERED BORE BEARING EXAMPLE: SNT 512 610 BEARING: 21310K LOCATING RINGS: SR110X10.5 SLEEVE: H310 SEAL OPTIONS DOUBLE-LIP: TSNG610 LOR: LO610 V-RING: VR610 TACONITE: TA610 END COVER: EC512-610 BEARING: 22310K LOCATING RINGS: SR110X4 SLEEVE: H2310 SEAL OPTIONS DOUBLE-LIP: TSNG610 LOR: LO610 V-RING: VR610 TACONITE: TA610 END COVER: EC512-610 BEARING: 22212K LOCATING RINGS: SR110X10 SLEEVE: H312 SEAL OPTIONS DOUBLE-LIP: TSNG512 LOR: LO512 V-RING: VR512 TACONITE: TA512 END COVER: EC512-610 TIMKEN SNT SPLIT PLUMMER BLOCKS 7

SNT NOMENCLATURE: 0 0 AND 0 0 SERIES _ SNT _ HOUSING 5 1 2-6 1 0 LOCATING RING SR 1 1 0 X 1 0. 5 Blank = two-bolt base F = four-bolt base Blank = cast iron D = ductile iron Bore code Housing series: 2 = 0 3 = 0 5 = 0 6 = 0 Bore code O.D. (mm) Width (mm) SLEEVE (1) H 3 1 0 SEAL HOUSING SIZE T S N G 6 1 0 H = adapter sleeve Series Bore code (1) Adapter sleeve includes locknut and lockwasher/lock plate TSNG = double-lip LO = labyrinth w/ O-ring VR = V-ring TA = taconite EC = end cover Bore code Housing series: 2 = 0 3 = 0 5 = 0 6 = 0 SNT NOMENCLATURE: 00 AND 3100 SERIES HOUSING S N T D 3 1 3 6 LOCATING RING SR 3 0 0 X 1 0 D = ductile iron Bore code O.D. (mm) Width (mm) N = light series (cast iron) Housing series: = 00 31 = 3100 F = fixed L = float Blank = fixed or float (use locating rings for fixed, no locating rings for float) SLEEVE (1) O H 3 1 3 6 H SEAL L O 3 6 H = adapter sleeve OH = hydraulic sleeve Series Bore code H = oil hole on nut end LO = labyrinth w/ O-ring TA = taconite EC = end cover Bore code (1) Adapter sleeve includes locknut and lockwasher/lock plate 8 TIMKEN SNT SPLIT PLUMMER BLOCKS

TAPERED BORE BEARING ASSEMBLY Typically, spherical roller bearings with tapered bore bearings are selected to simplify shaft mounting and dismounting. Mounting can be simplified by use of an adapter sleeve with a cylindrical bore and tapered O.D. Bearings with a tapered bore typically require a tighter fit on the shaft than bearings with a cylindrical bore. A locknut is typically used to drive the inner ring up a tapered shaft sleeve. The locknut position is then secured by use of a lockwasher or lockplate. For shaft sizes above 0 mm, hydraulic sleeves are offered to ease disassembly. Timken offers a wide range of accessories for the assembly housed units with tapered bore spherical roller bearings (see Timken Spherical Roller Bearing Catalog Or. 10446). TIMKEN HIGH-PERFORMANCE ROLLER HOUSED UNIT GREASE Experience the difference of a grease engineered specifically for roller housed units: Timken high-performance roller housed unit grease (Timken GR255). It s ideal for industrial applications with extreme loads, high wear, moderate speeds, high temperatures and shock loading. Compatible with most industrial materials and able to operate within a wide temperature range, our high-performance roller housed unit grease is one more answer from Timken for efficient, reliable operations in tough environments. TIMKEN SNT SPLIT PLUMMER BLOCKS 9

HOUSING STRENGTH Timken SNT housed units are intended to be mounted with the base fully supported and loads applied directly into the base. Housing strength may become the limiting factor in applications where load is not applied directly into the base or if the base is unsupported. In those cases, housing safe loads should be considered. Safe load guidelines for Timken SNT housings where load is not applied directly into the base or if the base is unsupported (P0) are shown in the tables below. The safe load guidelines have taken into account the breaking strength of the housing, the breaking strength of the cap bolts, and include appropriate safety factors. Safety factors are aligned with accepted engineering practices for the housing material and cap bolts. Additional safety factors may be applied by the user for safety critical applications. The published safe load values assume the housing has been properly secured to the base structure and proper torque has been applied to the cap bolts. Contact your Timken engineering or sales representative for any questions on housing strength or to discuss high-risk applications. P 0 P 55 P 90 P 1 P 1 P 0 P Axial SAFE LOAD 0/0 AND 0/0 SERIES - 2 AND 4 BOLT GRAY CAST IRON SAFE LOAD Housing Load Direction 0 55 90 1 1 0 Axial kn kn kn kn kn kn kn SNT 5, SNT 5 10 22 7 9 11 9 SNT 6-5, SNT 6-5 15 29 10 10 12 10 SNT 7, SNT 7-6 36 13 12 14 11 SNT 8-7, SNT 8-7 44 19 14 15 12 SNT 9, SNT 9 52 21 15 17 13 SNT 210, SNT 510-8 37 23 23 19 15 SNT 211, (F)SNT 511-9 44 69 25 22 SNT 212, (F)SNT 512-610 78 29 23 SNT 213, (F)SNT 513-611 57 87 33 25 27 19 SNT 215, (F)SNT 515-612 64 97 36 36 21 SNT 2, (F)SNT 5-613 71 107 41 39 33 23 SNT 217, (F)SNT 517 78 1 46 43 36 25 SNT 2, (F)SNT 5-615 86 1 52 46 39 40 27 (F)SNT 519-6 94 139 59 43 44 (F)SNT 5-617 102 151 66 54 47 48 (F)SNT 522-619 1 175 81 61 56 57 37 (F)SNT 5-6 138 1 99 68 66 67 43 (F)SNT 5 148 214 109 72 71 72 46 (F)SNT 5 7 2 1 82 83 52 (F)SNT 5 8 271 153 88 94 95 58 (F)SNT 5 199 6 6 92 101 102 62 Note: Safe Load (kn), ASTM A48, grade cast iron housings; class 8.8 cap bolts. SAFE LOAD 0/0 AND 0/0 SERIES - 2 AND 4 BOLT DUCTILE IRON SAFE LOAD Housing Load Direction 0 55 90 1 1 0 Axial kn kn kn kn kn kn kn SNTD 5, SNTD 5 33 34 42 43 45 29 SNTD 6-5, SNTD 6-5 39 44 36 39 45 45 SNTD 7, SNTD 7-6 47 56 40 37 47 46 SNTD 8-7, SNTD 8-7 56 69 44 37 48 SNTD 9, SNTD 9 66 83 49 37 53 33 SNTD 210, SNTD 510-8 76 98 55 39 57 53 SNTD 211, (F)SNTD 511-9 87 115 61 42 62 57 38 SNTD 212, (F)SNTD 512-610 99 1 69 46 67 61 40 SNTD 213, (F)SNTD 513-611 112 1 77 51 72 66 44 SNTD 215, (F)SNTD 515-612 1 1 85 58 79 72 47 SNTD 2, (F)SNTD 5-613 190 95 66 86 78 52 SNTD 217, (F)SNTD 517 156 212 105 74 93 85 56 SNTD 2, (F)SNTD 5-615 172 234 1 85 101 92 61 (F)SNTD 519-6 9 258 127 96 110 101 67 (F)SNTD 5-617 6 2 139 108 119 110 72 (F)SNTD 522-619 4 3 6 137 139 129 85 (F)SNTD 5-6 5 391 196 1 2 152 100 (F)SNTD 5 6 421 212 8 174 4 108 (F)SNTD 5 2 484 6 229 1 190 125 (F)SNTD 5 401 5 3 274 229 219 144 (F)SNTD 5 427 585 2 298 5 234 154 Note: Safe Load (kn), ASTM A536, grade 65-45 12 ductile iron housings; class 10.9 cap bolts. 10 TIMKEN SNT SPLIT PLUMMER BLOCKS

SAFE LOAD 00 SERIES DUCTILE IRON Housing SAFE LOAD Load Direction 0 55 90 1 1 0 Axial kn kn kn kn kn kn kn SNTD 36 499 798 434 5 442 451 2 SNTD 38 693 905 490 431 464 471 3 SNTD 40 787 961 5 467 477 483 3 SNTD 44 967 10 5 537 7 511 413 SNTD 48 1137 643 3 541 544 471 SNTD 52 1298 1341 8 665 5 582 5 SNTD 56 14 1482 776 722 623 625 583 SNTD 1592 845 776 671 673 638 SNTD 64 1725 1790 9 825 7 7 691 SNTD 68 48 1955 992 8 781 784 743 SNTD 72 1962 21 1069 911 843 847 794 SNTD 76 67 29 1148 949 910 9 843 SNTD 22 97 12 981 981 989 892 SNTD 84 27 93 1314 1010 1057 1067 939 SNTD 88 27 2795 17 1023 1097 1108 962 SNTD 92 02 1444 1046 1179 1193 1007 SNTD 96 1534 1064 17 14 1051 SNTD /0 73 3442 1079 19 13 1094 SNTD /5 2534 3791 1769 1093 16 1533 1156 Note: Safe Load (kn), ASTM A536, grade 65-45 12 ductile iron housings; class 10.9 cap bolts. SAFE LOAD 3100 SERIES DUCTILE IRON Housing SAFE LOAD Load direction 0 55 90 1 1 0 Axial kn kn kn kn kn kn kn SNTD 3134 437 563 395 339 466 468 311 SNTD 3136 521 6 421 3 474 475 310 SNTD 3138 6 1 449 383 484 485 310 SNTD 3 691 777 478 407 496 496 314 SNTD 3144 862 939 542 4 527 5 8 SNTD 3148 1033 1117 614 5 567 564 2 SNTD 3152 15 1311 692 581 614 611 386 SNTD 3156 1377 1521 778 651 671 666 4 SNTD 1549 1747 871 725 7 7 484 SNTD 34 1722 1989 971 5 8 2 548 SNTD 38 96 27 1079 891 890 883 622 SNTD 3172 2521 1193 982 9 973 6 SNTD 3176 25 10 1315 1079 1079 10 0 SNTD 31 1443 11 16 1177 904 SNTD 34 2596 3437 1579 18 11 1291 10 SNTD 38 84 34 1344 1362 12 1079 SNTD 3192 61 3949 1797 14 1490 14 SNTD 3196 38 4310 1951 1581 1347 Note: Safe Load (kn), ASTM A536, grade 65-45 12 ductile iron housings; class 10.9 cap bolts. RADIAL INTERNAL CLEARANCE RADIAL INTERNAL CLEARANCE CALCULATING RIC REDUCTION USING A SPHERICAL ROLLER BEARING WITH TAPERED BORE Given bearing number 2K C3 ( mm bore with C3 clearance) is to be mounted on a tapered shaft. Using a set of feeler gages, RIC is measured at: RIC = 0.178 mm Suggested reduction of RIC due to installation = 0.064 mm 0.089 mm, found in the RIC table for tapered bore. Calculate the clearance after mounting: 0.178 mm 0.076 mm = 0.102 mm For this example, the value of 0.076 mm was obtained by taking the mid-range value of the upper and lower limits found in the table on the next page. Therefore, the locknut should be tightened until RIC reaches 0.102 mm. Measure RIC before installation. After mounting, the RIC should be checked at the unloaded roller. It also should be noted that the value obtained by reading the suggested RIC after installation directly from the table is 0.056 mm. This differs from the value calculated in the example. The value taken directly from the table is provided as a minimum value. It is not suggested to use a calculated value that falls below this minimum. TIMKEN SNT SPLIT PLUMMER BLOCKS 11

RADIAL INTERNAL CLEARANCE (CONTINUED) MOUNTING TAPERED BORE SPHERICAL ROLLER BEARINGS Use a feeler gage with the thinnest blade of 0.038 mm. Place the bearing in an upright position with the inner and outer rings facing parallel. Place thumbs on the inner ring bore and oscillate the inner ring the distance of two or three roller spacings. Position the individual roller assemblies so that a roller is at the top of the inner ring on both sides of the bearing. With the roller in the correct position, insert a thin blade of the feeler gage between the roller and the outer ring. Move the feeler gage carefully along the top roller between the roller and outer ring raceway. Repeat this procedure using thicker feeler gage blades until one is found that will not go through. The blade thickness that preceded the no-go blade is a measure of RIC before installation. Start the mounting procedure by lubricating the tapered shaft with a light coat of machine oil. Slide the bearing onto the shaft as far as it will go by hand. As the locknut is tightened, the interference fit builds up, resulting in expansion of the inner ring. Periodically measure to monitor the reduction in RIC. Continue the procedure until the proper amount of reduction is obtained. Do not exceed calculated amount of reduction. As a final check, make sure the remaining RIC equals or exceeds the minimum mounted clearance shown in the table below. During mounting, the RIC should be checked at the unloaded roller. If this is at the bottom, make sure that the roller is raised to seat firmly at the inboard position of the inner ring. When the suggested amount of RIC reduction has been accomplished, the bearing is properly fitted. Complete the procedure by peening the lockwasher tang into the locknut slot or securing the lockplate. For more information about spherical roller bearings please refer to SRB catalog Or. 10446. RADIAL INTERNAL CLEARANCE LIMITS SPHERICAL ROLLER BEARINGS USED IN SNT HOUSINGS TAPERED BORE Bore (Nominal) Normal CO C4 Min. Max. Min. Max. C3 Suggested Reduction of RIC due to Installation Axial Displacement of Inner Ring for RIC Reduction SNT Tapered Sleeve Mounting (1) 1:12 Taper Minimum Permissible RIC after Installation (1) Over Incl. Min. Max. Min. Max. Min. Max. CO C3 C4 mm mm µm µm µm µm µm µm µm µm µm µm µm 40 55 75 15 253 3 15 25 40 40 65 85 25 3 4 15 25 40 40 45 100 25 4 6 65 55 75 95 1 38 6 6 25 40 65 95 1 1 38 51 6 836 25 45 75 100 110 0 46 64 748 1067 36 75 100 1 100 1 1 2 51 71 836 1177 51 100 1 1 0 0 2 64 89 979 1397 56 75 115 0 1 0 2 0 76 102 1254 72 56 75 125 0 0 0 2 340 76 114 1254 15 61 90 1 0 0 0 2 290 3 89 127 1540 90 71 100 5 0 225 0 2 3 410 102 72 2233 76 115 0 225 2 0 2 3 4 114 152 1958 2519 89 115 0 2 0 2 0 390 490 114 5 1958 2794 102 2 0 315 0 3 4 540 127 178 90 2937 102 1 2 315 5 2 3 4 590 190 2233 69 114 5 0 5 400 0 400 5 6 152 3 2519 35 127 190 3 400 4 3 440 5 7 5 2 2794 36 152 2 3 4 0 3 490 6 790 178 229 2937 3773 5 2 410 0 5 410 540 6 8 3 254 35 4191 178 290 440 RADIAL INTERNAL CLEARANCE LIMITS SPHERICAL ROLLER BEARINGS USED IN SNT HOUSINGS CYLINDRICAL BORE Bore (Nominal) Normal CO C4 Min. Max. Min. Max. C3 Over Incl. Min. Max. mm mm µm µm µm µm 25 40 55 75 40 45 40 55 75 100 65 40 65 90 1 65 110 145 100 100 1 0 100 1 75 1 0 210 1 95 145 190 0 0 110 1 2 0 0 0 1 0 0 310 0 0 1 0 2 340 0 225 2 290 3 225 2 1 0 3 4 2 0 1 2 3 4 0 315 190 0 3 0 315 5 0 310 410 5 5 400 2 340 4 0 400 4 0 3 0 6 4 0 2 410 5 7 0 5 0 440 0 7 (1) This displacement is valid for assembly of tapered bore bearings on solid steel shafts and is measured from a line-to-line fit of the bearing bore to the tapered shaft. For questions on tapered shaft data, consult your Timken engineer. Note: Tolerance and shaft diameters are shown in the table as variances from nominal bearing bore. 12 TIMKEN SNT SPLIT PLUMMER BLOCKS

SHAFT LENGTH GUIDELINES SHAFT END CLEARANCE VALUES The tables below provide the minimum required (S1) and maximum possible (S2) shaft lengths for cases where the shaft ending is inside the housing. The values provide guidance for shaft design, but may not take into account all application conditions like float and axial expansion. The minimum and maximum shaft length values are dimensioned from the center of the housing. Please contact your Timken representative if any special requirements are needed. S2 0d S2 C 0d S1 S1 MINIMUM AND MAXIMUM SHAFT LENGTHS 0/0 AND 0/0 SERIES 2 AND 4 BOLT Housing S1 S2 mm mm SNT 5, SNT 5 23 SNT 6-5, SNT 6-5 19 29 SNT 7, SNT 7-6 22 SNT 8-7, SNT 8-7 23 SNT 9, SNT 9 31 SNT 210, SNT 510-8 34 SNT 211, (F)SNT 511-9 36 SNT 212, (F)SNT 512-610 33 41 SNT 213, (F)SNT 513-611 44 SNT 215, (F)SNT 515-612 37 46 SNT 2, (F)SNT 5-613 39 49 SNT 217, (F)SNT 517 37 51 SNT 2, (F)SNT 5-615 45 59 (F)SNT 519-6 47 (F)SNT 5-617 51 68 (F)SNT 522-619 57 73 (F)SNT 5-6 61 79 (F)SNT 5 64 82 (F)SNT 5 69 89 (F)SNT 5 75 95 (F)SNT 5 81 104 MINIMUM AND MAXIMUM SHAFT LENGTHS LIGHT SERIES 00 Housing S1 S2 mm mm SNTN 46 72 SNTN 79 SNTN 52 79 SNTN 55 87 SNTN 59 87 SNTN 34 63 92 MINIMUM AND MAXIMUM SHAFT LENGTHS 00 SERIES Housing S1 S2 mm mm SNTD 36 54 84 SNTD 38 66 89 SNTD 40 63 98 SNTD 44 66 108 SNTD 48 78 113 SNTD 52 75 122 SNTD 56 89 129 SNTD 86 129 SNTD 64 83 144 SNTD 68 90 154 SNTD 72 90 153 SNTD 76F 93 9 SNTD 76L 93 9 SNTD F 97 9 SNTD L 97 9 SNTD 84F 98 9 SNTD 84L 98 9 SNTD 88F 110 4 SNTD 88L 110 4 SNTD 92F 108 199 SNTD 92L 108 199 SNTD 96F 109 199 SNTD 96L 109 199 SNTD /0F 1 199 SNTD /0L 1 199 SNTD /5F 127 199 SNTD /5L 127 199 MINIMUM AND MAXIMUM SHAFT LENGTHS 3100 SERIES Housing S1 S2 mm mm SNTD 3134 57 84 SNTD 3136 61 89 SNTD 3138 71 98 SNTD 3 79 108 SNTD 3144 84 113 SNTD 3148 86 122 SNTD 3152 99 129 SNTD 3156 99 129 SNTD 99 144 SNTD 34 108 154 SNTD 38F 1 9 SNTD 38L 1 9 SNTD 3172F 125 9 SNTD 3172L 125 9 SNTD 3176F 1 9 SNTD 3176L 1 9 SNTD F 133 4 SNTD L 133 4 SNTD 34F 148 199 SNTD 34L 148 199 SNTD 38F 149 199 SNTD 38L 149 199 SNTD 3192F 1 4 SNTD 3192L 1 4 SNTD 3196F 5 4 SNTD 3196L 5 4 TIMKEN SNT SPLIT PLUMMER BLOCKS 13

TWO-BOLT SNT HOUSINGS FOR TAPERED BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Double-Lip Seal V-Ring Seal Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) Adapter Sleeve (2) Double-Lip Seal (3) V-Ring Seal (3) Labyrinth Seal (4) Taconite Seal (4) End Cover (4) d O.D. x Width mm 25 40 45 55 SNT 5 225K SR52X3.5 H5 TSNG5 VR5 LO5 TA5 EC5 SNT 6-5 215K SR62X7.5 H5 TSNG5 VR5 LO5 TA5 EC6-5 SNT 6-5 2K SR62X6 H6 TSNG6 VR6 LO6 TA6 EC6-5 SNT 7-6 216K SR72X7.5 H6 TSNG6 VR6 LO6 TA6 EC7-6 SNT 7-6 227K SR72X5.5 H7 TSNG7-5 VR7 LO7 TA7 EC7-6 SNT 8-7 217K SRX9 H7 TSNG7 VR7 LO7 TA7 EC8-7 SNT 8-7 2K SRX8 H8 TSNG8 VR8 LO8 TA8 EC8-7 SNT 510-8 218K SR90X9 H8 TSNG8 VR8 LO8 TA8 EC510-8 SNT 510-8 228K SR90X4 H28 TSNG8 VR8 LO8 TA8 EC510-8 SNT 9 229K SR85X3.5 H9 TSNG9 VR9 LO9 TA9 EC9 SNT 511-9 219K SR100X9.5 H9 TSNG9 VR9 LO9 TA9 EC511-9 SNT 511-9 229K SR100X4 H29 TSNG9 VR9 LO9 TA9 EC511-9 SNT 510-8 22210K SR90X9 H310 TSNG510-7 VR510 LO510 TA510 EC510-8 SNT 512-610 21310K SR110X10.5 H310 TSNG610 VR610 LO610 TA610 EC512-610 SNT 512-610 22310K SR110X4 H2310 TSNG610 VR610 LO610 TA610 EC512-610 SNT 511-9 22211K SR100X9.5 H311 TSNG511 VR511 LO511 TA511 EC511-9 SNT 513-611 21311K SR1X11 H311 TSNG611 VR611 LO611 TA611 EC513-611 SNT 513-611 22311K SR1X4 H2311 TSNG611 VR611 LO611 TA611 EC513-611 SNT 512-610 22212K SR110X10 H312 TSNG512 VR512 LO512 TA512 EC512-610 SNT 515-612 21312K SR1X12.5 H312 TSNG612 VR612 LO612 TA612 EC515-612 SNT 515-612 22312K SR1X5 H2312 TSNG612 VR612 LO612 TA612 EC515-612 SNT 513-611 22213K SR1X10 H313 TSNG513 VR513 LO513 TA513 EC513-611 SNT 5-613 21313K SRX12.5 H313 TSNG613 VR613 LO613 TA613 EC5-613 SNT 5-613 22313K SRX5 H2313 TSNG613 VR613 LO613 TA613 EC5-613 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Double-lip and V-ring seals sold two seals per box. (4) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 14 TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES Grease hole fittings and plugs use 1 8 BSPT thread size for all housings up to 5-617. Housings 522-619 and larger use 1 4 BSPT thread size. Housings shown are furnished in cast iron. If ductile iron is desired, add the letter D to the alpha prefix (e.g., SNTD 5). Housing Dimensions A A 1 A 2 A 3 H H 1 H 2 J L N N 1 G 2 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm kg 67 46 1 74 40 19 1 5 15 12 1.5 77 52 89 1 89 22 1 5 15 12 2.0 77 52 89 1 89 22 1 5 15 12 2.0 82 52 94 93 22 1 5 15 12 2.2 82 52 94 93 22 1 5 15 12 2.2 85 97 145 108 25 1 5 15 12 2.9 85 97 145 108 25 1 5 15 12 2.9 90 102 1 113 25 1 5 15 12 3.2 90 102 1 113 25 1 5 15 12 3.2 85 97 1 109 25 1 5 15 12 2.9 95 107 155 1 210 255 4.5 95 107 155 1 210 255 4.5 90 102 1 113 25 1 5 15 12 3.2 105 117 5 134 210 255 5.3 105 117 5 134 210 255 5.3 95 107 155 1 210 255 4.5 110 122 1 1 2 275 6.6 110 122 1 1 2 275 6.6 105 117 5 134 210 255 5.3 115 127 175 156 2 0 6.9 115 127 175 156 2 0 6.9 110 122 1 1 2 275 6.6 1 90 138 0 177 95 2 315 22 9.7 1 90 138 0 177 95 2 315 22 9.7 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 15

TWO-BOLT SNT HOUSINGS FOR TAPERED BORE BEARINGS Continued from previous page. Double-Lip Seal V-Ring Seal Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) Adapter Sleeve (2) Double-Lip Seal (3) V-Ring Seal (3) Labyrinth Seal (4) Taconite Seal (4) End Cover (4) d O.D. x Width mm 65 75 85 90 100 110 115 125 1 SNT 515-612 22215K SR1X12.5 H315 TSNG515 VR515 LO515 TA515 EC515-612 SNT 5-615 21315K SR0X14 H315 TSNG615 VR615 LO615 TA615 EC5-615 SNT 5-615 22315K SR0X5 H2315 TSNG615 VR615 LO615 TA615 EC5-615 SNT 5-613 222K SRX12.5 H3 TSNG5 VR5 LO5 TA5 EC5-613 SNT 519-6 213K SR1X14.5 H3 TSNG6 VR6 LO6 TA6 EC519-6 SNT 519-6 223K SR1X5 H23 TSNG6 VR6 LO6 TA6 EC519-6 SNT 517 22217K SR1X12.5 H317 TSNG517 VR517 LO517 TA517 EC517 SNT 5-617 21317K SR0X14.5 H317 TSNG617 VR617 LO617 TA617 EC5-617 SNT 5-617 22317K SR0X5 H2317 TSNG617 VR617 LO617 TA617 EC5-617 SNT 5-615 222K SR0X12.5 H3 TSNG5 VR5 LO5 TA5 EC5-615 SNT 5-615 2K SR0X6.25 H23 TSNG5 VR5 LO5 TA5 EC5-615 SNT 519-6 22219K SR1X12.5 H319 TSNG519 VR519 LO519 TA519 EC519-6 SNT 522-619 21319K SR0X17.5 H319 TSNG619 VR619 LO619 TA619 EC522-619 SNT 522-619 22319K SR0X6.5 H2319 TSNG619 VR619 LO619 TA619 EC522-619 SNT 5-617 222K SR0X12 H3 TSNG5 VR5 LO5 TA5 EC5-617 SNT 5-617 2K SR0X4.85 H23 TSNG5 VR5 LO5 TA5 EC5-617 SNT 5-6 213K SR215X19.5 H3 TSNG6 VR6 LO6 TA6 EC5-6 SNT 5-6 223K SR215X6.5 H23 TSNG6 VR6 LO6 TA6 EC5-6 SNT 522-619 22222K SR0X13.5 H2 TSNG522 VR522 LO522 TA522 EC522-619 SNT 522-619 222K SR0X5.1 H22 TSNG522 VR522 LO522 TA522 EC522-619 SNT 5-6 222K SR215X14 H31 TSNG5 VR5 LO5 TA5 EC5-6 SNT 5-6 2K SR215X5 H23 TSNG5 VR5 LO5 TA5 EC5-6 SNT 5 222K SR2X13 H31 TSNG5 VR5 LO5 TA5 EC5 SNT 5 2K SR2X5 H TSNG5 VR5 LO5 TA5 EC5 SNT 5 222K SR2X15 H31 TSNG5 VR5 LO5 TA5 EC5 SNT 5 2K SR2X5 H TSNG5 VR5 LO5 TA5 EC5 SNT 5 222K SR2X.5 H31 TSNG5 VR5 LO5 TA5 EC5 SNT 5 2K SR2X5 H23 TSNG5 VR5 LO5 TA5 EC5 SNT 5 222K SR290X17 H31 TSNG5 VR5 LO5 TA5 EC5 SNT 5 2K SR290X5 H23 TSNG5 VR5 LO5 TA5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Double-lip and V-ring seals sold two seals per box. (4) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES (CONTINUED) Housing Dimensions A A 1 A 2 A 3 H H 1 H 2 J L N N 1 G 2 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm kg 115 127 175 156 2 0 6.9 100 158 225 194 100 290 345 22 13.1 100 158 225 194 100 290 345 22 13.1 1 90 138 0 177 95 2 315 22 9.7 145 100 3 2 212 112 290 345 22 14.0 145 100 3 2 212 112 290 345 22 14.0 125 90 143 210 3 95 2 3 22 10.4 0 110 178 2 2 112 40 3 3 17.6 0 110 178 2 2 112 40 3 3 17.6 100 158 225 194 100 290 345 22 13.1 100 158 225 194 100 290 345 22 13.1 145 100 3 2 212 112 290 345 22 14.0 175 1 191 2 2 125 45 344 410 22.3 175 1 191 2 2 125 45 3 410 22.3 0 110 178 2 2 112 40 3 3 17.6 0 110 178 2 2 112 40 3 3 17.6 5 1 199 2 271 45 3 410.5 5 1 199 2 271 45 3 410.5 175 1 191 2 2 125 45 3 410 22.3 175 1 191 2 2 125 45 3 410 22.3 5 1 199 2 271 45 3 410.5 5 1 199 2 271 45 3 410.5 190 1 8 5 290 1 3 445 34.0 190 1 8 5 290 1 3 445 34.0 5 1 223 5 2 1 4 0 42 39.0 5 1 223 5 2 1 4 0 42 39.0 2 0 1 295 3 0 4 5 42 48.0 2 0 1 295 3 0 4 5 42 48.0 2 0 254 315 344 1 4 5 42 54.5 2 0 254 315 344 1 4 5 42 54.5 TIMKEN SNT SPLIT PLUMMER BLOCKS 17

FOUR-BOLT FSNT HOUSINGS FOR TAPERED BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Double-Lip Seal V-Ring Seal Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) Adapter Sleeve (2) Double-Lip Seal (3) V-Ring Seal (3) Labyrinth Seal (4) Taconite Seal (4) End Cover (4) d O.D. x Width mm 40 45 55 65 75 FSNT 511-9 219K SR100X9.5 H9 TSNG9 VR9 LO9 TA9 EC511-9 FSNT 511-9 229K SR100X4 H29 TSNG9 VR9 LO9 TA9 EC511-9 FSNT 512-610 21310K SR110X10.5 H310 TSNG610 VR610 LO610 TA610 EC512-610 FSNT 512-610 22310K SR110X4 H2310 TSNG610 VR610 LO610 TA610 EC512-610 FSNT 511-9 22211K SR100X9.5 H311 TSNG511 VR511 LO511 TA511 EC511-9 FSNT 513-611 21311K SR1X11 H311 TSNG611 VR611 LO611 TA611 EC513-611 FSNT 513-611 22311K SR1X4 H2311 TSNG611 VR611 LO611 TA611 EC513-611 FSNT 512-610 22212K SR110X10 H312 TSNG512 VR512 LO512 TA512 EC512-610 FSNT 515-612 21312K SR1X12.5 H312 TSNG612 VR612 LO612 TA612 EC515-612 FSNT 515-612 22312K SR1X5 H2312 TSNG612 VR612 LO612 TA612 EC515-612 FSNT 513-611 22213K SR1X10 H313 TSNG513 VR513 LO513 TA513 EC513-611 FSNT 5-613 21313K SRX12.5 H313 TSNG613 VR613 LO613 TA613 EC5-613 FSNT 5-613 22313K SRX5 H2313 TSNG613 VR613 LO613 TA613 EC5-613 FSNT 515-612 22215K SR1X12.5 H315 TSNG515 VR515 LO515 TA515 EC515-612 FSNT 5-615 21315K SR0X14 H315 TSNG615 VR615 LO615 TA615 EC5-615 FSNT 5-615 22315K SR0X5 H2315 TSNG615 VR615 LO615 TA615 EC5-615 FSNT 5-613 222K SRX12.5 H3 TSNG5 VR5 LO5 TA5 EC5-613 FSNT 519-6 213K SR1X14.5 H3 TSNG6 VR6 LO6 TA6 EC519-6 FSNT 519-6 223K SR1X5 H23 TSNG6 VR6 LO6 TA6 EC519-6 FSNT 517 22217K SR1X12.5 H317 TSNG517 VR517 LO517 TA517 EC517 FSNT 5-617 21317K SR0X14.5 H317 TSNG617 VR617 LO617 TA617 EC5-617 FSNT 5-617 22317K SR0X5 H2317 TSNG617 VR617 LO617 TA617 EC5-617 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Double-lip and V-ring seals sold two seals per box. (4) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES Grease hole fittings and plugs use 1 8 BSPT thread size for all housings up to 5-617. Housings 522-619 and larger use 1 4 BSPT thread size. Assemblies shown are furnished in cast iron. If ductile iron is desired, add the letter D to the alpha prefix (e.g., FSNTD 5). Housing Dimensions A A 1 A 2 A 3 H H 1 H 2 J J 1 L N N 1 G 4 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm mm kg 95 107 155 1 210 255 15 12 4.5 95 107 155 1 210 255 15 12 4.5 105 117 5 134 210 255 15 12 5.3 105 117 5 134 210 255 15 12 5.3 95 107 155 1 210 255 15 12 4.5 110 122 1 1 2 40 275 15 12 6.6 110 122 1 1 2 40 275 15 12 6.6 105 117 5 134 210 255 15 12 5.3 115 127 175 156 2 40 0 15 12 6.9 115 127 175 156 2 40 0 15 12 6.9 110 122 1 1 2 40 275 15 12 6.6 1 90 138 0 177 95 2 315 9.7 1 90 138 0 177 95 2 315 9.7 115 127 175 156 2 40 0 15 12 6.9 100 158 225 194 100 290 345 13.1 100 158 225 194 100 290 345 13.1 1 90 138 0 177 95 2 315 9.7 145 100 3 2 212 112 290 345 14 145 100 3 2 212 112 290 345 14 125 90 143 210 3 95 2 3 10.4 0 110 178 2 2 112 40 3 3 17.6 0 110 178 2 2 112 40 3 3 17.6 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 19

FOUR-BOLT FSNT HOUSINGS FOR TAPERED BORE BEARINGS Continued from previous page. Double-Lip Seal V-Ring Seal Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) Adapter Sleeve (2) Double-Lip Seal (3) V-Ring Seal (3) Labyrinth Seal (4) Taconite Seal (4) End Cover (4) d O.D. x Width mm 85 90 100 110 115 125 1 FSNT 5-615 222K SR0X12.5 H3 TSNG5 VR5 LO5 TA5 EC5-615 FSNT 5-615 2K SR0X6.25 H23 TSNG5 VR5 LO5 TA5 EC5-615 FSNT 519-6 22219K SR1X12.5 H319 TSNG519 VR519 LO519 TA519 EC519-6 FSNT 522-619 21319K SR0X17.5 H319 TSNG619 VR619 LO619 TA619 EC522-619 FSNT 522-619 22319K SR0X6.5 H2319 TSNG619 VR619 LO619 TA619 EC522-619 FSNT 5-617 222K SR0X12 H3 TSNG5 VR5 LO5 TA5 EC5-617 FSNT 5-617 2K SR0X4.85 H23 TSNG5 VR5 LO5 TA5 EC5-617 FSNT 5-6 213K SR215X19.5 H3 TSNG6 VR6 LO6 TA6 EC5-6 FSNT 5-6 223K SR215X6.5 H23 TSNG6 VR6 LO6 TA6 EC5-6 FSNT 522-619 22222K SR0X13.5 H2 TSNG522 VR522 LO522 TA522 EC522-619 FSNT 522-619 222K SR0X5.1 H22 TSNG522 VR522 LO522 TA522 EC522-619 FSNT 5-6 222K SR215X14 H31 TSNG5 VR5 LO5 TA5 EC5-6 FSNT 5-6 2K SR215X5 H23 TSNG5 VR5 LO5 TA5 EC5-6 FSNT 5 222K SR2X13 H31 TSNG5 VR5 LO5 TA5 EC5 FSNT 5 2K SR2X5 H TSNG5 VR5 LO5 TA5 EC5 FSNT 5 222K SR2X15 H31 TSNG5 VR5 LO5 TA5 EC5 FSNT 5 2K SR2X5 H TSNG5 VR5 LO5 TA5 EC5 FSNT 5 222K SR2X.5 H31 TSNG5 VR5 LO5 TA5 EC5 FSNT 5 2K SR2X5 H23 TSNG5 VR5 LO5 TA5 EC5 FSNT 5 222K SR290X17 H31 TSNG5 VR5 LO5 TA5 EC5 FSNT 5 2K SR290X5 H23 TSNG5 VR5 LO5 TA5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Double-lip and V-ring seals sold two seals per box. (4) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES (CONTINUED) Housing Dimensions A A 1 A 2 A 3 H H 1 H 2 J J 1 L N N 1 G 4 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm mm kg 100 158 225 194 100 290 345 13.1 100 158 225 194 100 290 345 13.1 145 100 3 2 212 112 290 345 14 175 1 191 2 2 125 45 3 410 22.3 175 1 191 2 2 125 45 3 410 22.3 0 110 178 2 2 112 40 3 3 17.6 0 110 178 2 2 112 40 3 3 17.6 5 1 199 2 271 45 3 410.5 5 1 199 2 271 45 3 410.5 175 1 191 2 2 125 45 3 410 22.3 175 1 191 2 2 125 45 3 410 22.3 5 1 199 2 271 45 3 410.5 5 1 199 2 271 45 3 410.5 190 1 8 5 290 1 3 445 22 34 190 1 8 5 290 1 3 445 22 34 5 1 223 5 2 1 4 0 39 5 1 223 5 2 1 4 0 39 2 0 1 295 3 0 4 90 5 48 2 0 1 295 3 0 4 90 5 48 2 0 254 315 344 1 4 90 5 54.5 2 0 254 315 344 1 4 90 5 54.5 TIMKEN SNT SPLIT PLUMMER BLOCKS 21

TWO-BOLT SNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Double-Lip Seal V-Ring Seal Labyrinth Seal Shaft Dia. Housing Bearing Locating Rings (1) Double-Lip Seal (2) V-Ring Seal (2) Labyrinth Seal (3) End Cover (3) da db O.D. x Width mm mm 25 SNT 5 SNT 6-5 225 215 SR52X3.5 SR62X7.5 TSNG5 TSNG7-5 VR5 LO5 LO5 EC6-5 EC7-6 SNT 6-5 SNT 7-6 2 216 SR62X6 SR72X7.5 TSNG6-6 TSNG6-6 VR6 VR6 LO6 LO6 EC7-6 EC7-6 45 SNT 7 SNT 8-7 227 217 SR72X5.5 SRX9 TSNG7 TSNG510-7 VR7 VR7 LO7 LO7 EC9 EC510-8 40 SNT 8-7 SNT 510-8 SNT 510-8 2 218 228 SRX8 SR90X9 SR90X4 TSNG8-8 TSNG8-8 TSNG8-8 VR8 VR8 VR8 LO8 LO8 LO8 EC510-8 EC510-8 EC510-8 45 55 SNT 9 SNT 511-9 SNT 511-9 229 219 229 SR85X3.5 SR100X9.5 SR100X4 TSNG9-9 TSNG9-9 TSNG9-9 VR9 VR9 VR9 LO9 LO9 LO9 EC511-9 EC511-9 EC511-9 SNT 210 SNT 512-610 SNT 512-610 22210 21310 22310 SR90X9 SR110X10.5 SR110X4 TSNG310-210 TSNG310-210 TSNG310-210 VR210 VR310 VR310 LO210 LO310 LO310 EC512-610 EC512-610 EC512-610 55 65 SNT 211 SNT 513-611 SNT 513-611 22211 21311 22311 SR100X9.5 SR1X11 SR1X4 TSNG311-211 TSNG311-211 TSNG311-211 VR211 VR311 VR311 LO211 LO311 LO311 EC513-611 EC513-611 EC513-611 SNT 212 SNT 515-612 SNT 515-612 22212 21312 22312 SR110X10 SR1X12.5 SR1X5 TSNG312-212 TSNG312-212 TSNG312-212 VR212 VR312 VR312 LO212 LO312 LO312 EC515-612 EC515-612 EC515-612 65 75 SNT 213 SNT 5-613 SNT 5-613 22213 21313 22313 SR1X10 SRX12.5 SRX5 TSNG313-213 TSNG313-213 TSNG313-213 VR213 VR313 VR313 LO213 LO313 LO313 EC5-613 EC5-613 EC5-613 SNT 517 SNT 517 22314 21314 SR1X5 SR1X13 TSNG314 TSNG314 VR314 VR314 LO314 LO314 EC517 EC517 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Double-lip and V-ring seals sold two seals per box. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 22 TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES Grease hole fittings and plugs use 1 8 BSPT thread size for all housings up to 5-617. Housings 522-619 and larger use 1 4 BSPT thread size. Assemblies shown are furnished in cast iron. If ductile iron is desired, add the letter D to the alpha prefix (e.g., SNTD 5). Seal sleeve for d a shaft to be supplied by customer and should have same O.D. as d b. Housing Dimensions A A1 A2 A3 H H1 H2 J L N N1 G 2 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm kg 67 77 46 52 90 89 1 74 89 40 19 22 1 1 5 5 15 15 12 12 1.5 2 77 82 52 52 89 94 1 89 93 22 22 1 1 5 5 15 15 12 12 2 2.2 82 85 52 96 99 155 0 93 108 22 25 1 1 5 5 15 15 12 12 2.2 2.9 85 90 90 99 102 102 0 1 1 108 113 113 25 25 25 1 1 1 5 5 5 15 15 15 12 12 12 2.9 3.2 3.2 85 95 95 97 107 107 0 155 155 109 1 1 25 1 210 210 5 255 255 15 12 2.9 4.5 4.5 90 105 105 102 117 117 5 5 5 113 134 134 25 1 210 210 5 255 255 15 12 3.2 5.3 5.3 95 110 110 107 122 122 1 1 1 1 1 1 210 2 2 255 275 275 4.5 6.6 6.6 105 115 115 117 127 127 0 175 175 134 156 156 210 2 2 255 0 0 5.2 6.9 6.9 110 1 1 90 90 1 138 138 190 0 0 149 177 177 95 95 2 2 2 275 315 315 22 22 6.6 9.7 9.7 125 125 90 90 143 143 210 210 3 3 95 95 2 2 3 3 22 22 10.4 10.4 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 23

TWO-BOLT SNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS Continued from previous page. Double-Lip Seal V-Ring Seal Labyrinth Seal Shaft Dia. Housing Bearing Locating Rings (1) Double-Lip Seal (2) V-Ring Seal (2) Labyrinth Seal (3) End Cover (3) da db O.D. x Width mm mm 75 85 SNT 215 SNT 5-615 SNT 5-615 22215 21315 22315 SR1X12.5 SR0X14 SR0X5 TSNG315-215 TSNG315-215 TSNG315-215 VR215 VR315 VR315 LO215 LO315 LO315 EC5-615 EC5-615 EC5-615 90 SNT 2 SNT 519-6 SNT 519-6 222 213 223 SRX10 SR1X14.5 SR1X5 TSNG2 TSNG3 TSNG3 VR2 VR3 VR3 LO2 LO3 LO3 EC2 EC519-6 EC519-6 85 95 SNT 217 SNT 5-617 SNT 5-617 22217 21317 22317 SR1X12.5 SR0X14.5 SR0X5 TSNG217 TSNG317 TSNG317 VR217 VR317 VR317 LO217 LO317 LO317 EC217 EC5-617 EC5-617 90 100 SNT 2 SNT 2 222 2 SR0X12.5 SR0X6.25 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC2 EC2 95 110 SNT 522-619 SNT 522-619 21319 22319 SR0X17.5 SR0X6.5 TSNG319 TSNG319 VR319 VR319 LO319 LO319 EC522-619 EC522-619 100 115 SNT 5-617 SNT 5-617 SNT 5-6 SNT 5-6 222 2 213 223 SR0X12 SR0X4.85 SR215X19.5 SR215X6.5 TSNG2 TSNG2 TSNG3 TSNG3 VR2 VR2 VR3 VR3 LO2 LO2 LO3 LO3 EC5-617 EC5-617 EC5-6 EC5-6 110 125 SNT 522-619 SNT 522-619 22222 222 SR0X13.5 SR0X5.1 TSNG222 TSNG222 VR222 VR222 LO222 LO222 EC522-619 EC522-619 1 1 SNT 5-6 SNT 5-6 222 2 SR215X14 SR215X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5-6 EC5-6 1 145 SNT 5 SNT 5 222 2 SR2X13 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 155 SNT 5 SNT 5 222 2 SR2X15 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 1 5 SNT 5 SNT 5 222 2 SR2X.5 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 0 175 SNT 5 SNT 5 222 2 SR290X17 SR290X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Double-lip and V-ring seals sold two seals per box. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

TIMKEN SNT SPLIT PLUMMER BLOCKS 25 0/0 SERIES (CONTINUED) Housing Dimensions 2 Bolts Req d Housing Mass A A1 A2 A3 H H1 H2 J L N N1 G mm mm mm mm mm mm mm mm mm mm mm mm kg 115 100 100 133 158 158 195 225 225 155 194 194 100 100 2 290 290 0 345 345 22 22 6.9 13.1 13.1 1 145 145 90 100 100 138 3 3 0 2 2 177 212 212 95 112 112 2 290 290 315 345 345 22 22 22 9.7 14.0 14.0 125 0 0 90 110 110 143 178 178 5 2 2 3 2 2 95 112 112 40 40 2 3 3 3 3 3 22 10.4 17.6 17.6 100 100 158 158 2 2 194 194 100 100 290 290 345 345 22 22 13.1 13.1 175 175 1 1 191 191 2 2 2 2 125 125 45 45 3 3 410 410 22.3 22.3 0 0 5 5 110 110 1 1 178 178 199 199 2 2 2 2 2 2 271 271 112 112 40 40 45 45 3 3 3 3 3 3 410 410 17.6 17.6.5.5 175 175 1 1 191 191 2 2 2 2 125 125 45 45 3 3 410 410 22.3 22.3 5 5 1 1 199 199 2 2 271 271 45 45 3 3 410 410.5.5 190 190 1 1 8 8 5 5 290 290 1 1 3 3 445 445 34.0 34.0 5 5 1 1 223 223 5 5 2 2 1 1 4 4 0 0 42 42 39.0 39.0 2 2 0 0 1 1 295 295 3 3 0 0 4 4 5 5 42 42 48.0 48.0 2 2 0 0 254 254 315 315 344 344 1 1 4 4 5 5 42 42 54.5 54.5

FOUR-BOLT FSNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Double-Lip Seal V-Ring Seal Labyrinth Seal Shaft Dia. Housing Bearing Locating Rings (1) Double-Lip Seal (2) V-Ring Seal (2) Labyrinth Seal (3) End Cover (3) da db O.D. x Width mm mm 45 55 FSNT 511-9 FSNT 511-9 219 229 SR100X9.5 SR100X4 TSNG9-9 TSNG9-9 VR9 VR9 LO9 LO9 EC511-9 EC511-9 FSNT 512-610 FSNT 512-610 21310 22310 SR110X10.5 SR110X4 TSNG310-210 TSNG310-210 VR310 VR310 LO310 LO310 EC512-610 EC512-610 55 65 FSNT 513-611 FSNT 513-611 21311 22311 SR1X11 SR1X4 TSNG311-211 TSNG311-211 VR311 VR311 LO311 LO311 EC513-611 EC513-611 FSNT 515-612 FSNT 515-612 21312 22312 SR1X12.5 SR1X5 TSNG312-212 TSNG312-212 VR312 VR312 LO312 LO312 EC515-612 EC515-612 65 75 FSNT 5-613 FSNT 5-613 21313 22313 SRX12.5 SRX5 TSNG313-213 TSNG313-213 VR313 VR313 LO313 LO313 EC5-613 EC5-613 FSNT 517 FSNT 517 22314 21314 SR1X5 SR1X13 TSNG314 TSNG314 VR314 VR314 LO314 LO314 EC517 EC517 75 85 FSNT 5-615 FSNT 5-615 21315 22315 SR0X14 SR0X5 TSNG315-215 TSNG315-215 VR315 VR315 LO315 LO315 EC5-615 EC5-615 90 FSNT 519-6 FSNT 519-6 213 223 SR1X14.5 SR1X5 TSNG3 TSNG3 VR3 VR3 LO3 LO3 EC519-6 EC519-6 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Double-lip and V-ring seals sold two seals per box. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES Grease hole fittings and plugs use 1 8 BSPT thread size for all housings up to 5-617. Housings 522-619 and larger use 1 4 BSPT thread size. Assemblies shown are furnished in cast iron. If ductile iron is desired, add the letter D to the alpha prefix (e.g., SNTD 5). Seal sleeve for d a shaft to be supplied by customer and should have same O.D. as d b. Housing Dimensions 4 Bolts Req d Housing Mass A A1 A2 A3 H H1 H2 J J1 L N N1 G mm mm mm mm mm mm mm mm mm mm mm mm mm kg 95 95 107 107 155 155 1 1 210 210 255 255 15 15 12 12 4.5 4.5 105 105 117 117 5 5 134 134 210 210 255 255 15 15 12 12 5.3 5.3 110 110 122 122 1 1 1 1 2 2 40 40 275 275 15 15 12 12 6.6 6.6 115 115 127 127 175 175 156 156 2 2 40 40 0 0 15 15 12 12 6.9 6.9 1 1 90 90 138 138 0 0 177 177 95 95 2 2 315 315 9.7 9.7 125 125 90 90 143 143 210 210 3 3 95 95 2 2 3 3 10.4 10.4 100 100 158 158 225 225 194 194 100 100 290 290 345 345 13.1 13.1 145 145 100 100 3 3 2 2 212 212 112 112 290 290 345 345 14.0 14.0 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 27

FOUR-BOLT FSNT HOUSINGS FOR CYLINDRICAL BORE BEARINGS Continued from previous page. Double-Lip Seal V-Ring Seal Labyrinth Seal Shaft Dia. Housing Bearing Locating Rings (1) Double-Lip Seal (2) V-Ring Seal (2) Labyrinth Seal (3) End Cover (3) da db O.D. x Width mm mm 85 95 FSNT 5-617 FSNT 5-617 21317 22317 SR0X14.5 SR0X5 TSNG317 TSNG317 VR317 VR317 LO317 LO317 EC5-617 EC5-617 95 110 FSNT 522-619 FSNT 522-619 21319 22319 SR0X17.5 SR0X6.5 TSNG319 TSNG319 VR319 VR319 LO319 LO319 EC522-619 EC522-619 100 115 FSNT 5-617 FSNT 5-617 FSNT 5-6 FSNT 5-6 222 2 213 223 SR0X12 SR0X4.85 SR215X19.5 SR215X6.5 TSNG2 TSNG2 TSNG3 TSNG3 VR2 VR2 VR3 VR3 LO2 LO2 LO3 LO3 EC5-617 EC5-617 EC5-6 EC5-6 110 125 FSNT 522-619 FSNT 522-619 22222 222 SR0X13.5 SR0X5.1 TSNG222 TSNG222 VR222 VR222 LO222 LO222 EC522-619 EC522-619 1 1 FSNT 5-6 FSNT 5-6 222 2 SR215X14 SR215X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5-6 EC5-6 1 145 FSNT 5 FSNT 5 222 2 SR2X13 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 155 FSNT 5 FSNT 5 222 2 SR2X15 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 1 5 FSNT 5 FSNT 5 222 2 SR2X.5 SR2X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 0 175 FSNT 5 FSNT 5 222 2 SR290X17 SR290X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Double-lip and V-ring seal sold two seals per box. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

0/0 SERIES (CONTINUED) Housing Dimensions 4 Bolts Req d Housing Mass A A1 A2 A3 H H1 H2 J J1 L N N1 G mm mm mm mm mm mm mm mm mm mm mm mm mm kg 0 0 110 110 178 178 2 2 2 2 112 112 40 40 3 3 3 3 17.6 17.6 175 175 1 1 191 191 2 2 2 2 125 125 45 45 3 3 410 410 22.3 22.3 0 0 5 5 110 110 1 1 178 178 199 199 2 2 2 2 2 2 271 271 112 112 40 40 45 45 3 3 3 3 3 3 410 410 17.6 17.6.5.5 175 175 1 1 191 191 2 2 2 2 125 125 45 45 3 3 410 410 22.3 22.3 5 5 1 1 199 199 2 2 271 271 45 45 3 3 410 410.5.5 190 190 1 1 8 8 5 5 290 290 1 1 3 3 445 445 22 22 34 34 5 5 1 1 223 223 5 5 2 2 1 1 4 4 0 0 39 39 2 2 0 0 1 1 295 295 3 3 0 0 4 4 90 90 5 5 48 48 2 2 0 0 254 254 315 315 344 344 1 1 4 4 90 90 5 5 54.5 54.5 TIMKEN SNT SPLIT PLUMMER BLOCKS 29

FOUR-BOLT SNTD HOUSINGS FOR TAPERED BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) d O.D. x Width (1) Locating rings = sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Labyrinth, taconite seal and end cover sold one seal per box. Quantity Locating Rings Required for Fixed 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units Adapter Sleeve (2) Labyrinth Seal (3) Taconite Seal (3) End Cover (3) mm 115 SNTD 3134 2K SR0X7.5 2 H LO34/115 TA34/115 EC34 125 SNTD 3136 2K SR0X7 2 H LO36/125 TA36/125 EC36 1 SNTD 3138 223K SR3X8 2 H23 LO38/1 TA38/1 EC38 SNTD 38 222K SR290X17.5 2 H31 LO38/ TA38/ EC38 SNTD 38 2K SR290X5.5 2 H23 LO38/ TA38/ EC38 SNTD 3 223K SR340X9 2 H23 LO40/ TA40/ EC40 1 0 1 0 0 2 SNTD 3134 23134K SR0X10 2 H3134 LO34 TA34 EC34 SNTD 40 22234K SR310X 2 H3134 LO40/1 TA40/1 EC40 SNTD 48 22334K SR3X10 2 H2334 LO48/1 TA48/1 EC48 SNTD 36 236K SR0X17 2 H36 LO36 TA36 EC36 SNTD 3136 23136K SR0X10 2 H3136 LO36 TA36 EC36 SNTD 3138 22236K SR3X19 2 H3136 LO38/0 TA38/0 EC38 SNTD 38 238K SR290X10 4 H38 LO38 TA38 EC38 SNTD 3138 23138K SR3X10 2 H3138 LO38 TA38 EC38 SNTD 3 22238K SR340X10 4 H3138 LO40/1 TA40/1 EC40 SNTD 3148 22338K SR400X8 2 H2338 LO48/1 TA48/1 EC48 SNTD 40 240K SR310X10 4 H40 LO40 TA40 EC40 SNTD 3 23K SR340X10 2 H3 LO40 TA40 EC40 SNTD 48 2K SR3X21 2 H3 LO48/0 TA48/0 EC48 SNTD 56 22340K SR4X14 2 H2340 LO56/0 TA56/0 EC56 SNTD 44 244K SR340X10 4 OH44H LO44 TA44 EC44 SNTD 3144 23144K SR3X10 2 OH3144H LO44 TA44 EC44 SNTD 3148 224K SR400X10 4 OH3144H LO48/0 TA48/0 EC48 SNTD 3156 22344K SR4X10.5 2 OH2344H LO56/0 TA56/0 EC56 SNTD 48 248K SR3X12 4 OH48H LO48 TA48 EC48 SNTD 3148 23148K SR400X10 2 OH3148H LO48 TA48 EC48 SNTD 3152 2K SR440X22 2 OH3148H LO52/2 TA52/2 EC52 SNTD 22348K SR0X12.5 2 OH2348H LO/2 TA/2 EC TIMKEN SNT SPLIT PLUMMER BLOCKS

00 AND 3100 SERIES SNTD housings are supplied in ductile iron. Housings with the F suffix are manufactured for fixed bearings. Those with the L suffix are float position housings. Housing Dimensions 4 Bolts Req d A A 1 A 2 A 3 C H H 1 H 2 J J 1 L N N 1 G Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg 2 0 2.5 299.5 14 333 1 4 100 510 34 75.0 0 190 252.5 314.5 15 3 0 75 4 110 5 34 92.0 2 210 271.5 333.5 10 375 190 4 1 5 34 112.0 0 190 252 314 15 4 0 75 4 110 5 34 85.9 0 190 252 314 15 4 0 75 4 110 5 34 85.9 0 2 291.5 8.5 10 411 210 85 510 1 610 42 1.0 2 0 2.5 299.5 14 333 1 4 100 510 34 75.0 2 210 271 338 10 375 190 4 1 5 34 102.6 290 0 0 379.5 12 434 2 90 540 640 42 146.5 2 0 2 4 14 333 1 4 100 510 34 68.1 0 190 252.5 314.5 15 3 0 75 4 110 5 34 92.0 2 210 271.5 333.5 10 375 190 4 1 5 34 112.0 0 190 252 314 15 4 0 75 4 110 5 34 85.9 2 210 271.5 333.5 10 375 190 4 1 5 34 112.0 0 2 291.5 8.5 10 411 210 85 510 1 610 42 1.0 310 2 3.5 398 12 474 0 95 0 1 0 42 193.0 2 210 271 338 10 375 190 4 1 5 34 102.6 0 2 291.5 8.5 10 411 210 85 510 1 610 42 1.0 290 0 0 379.5 12 434 2 90 540 640 42 146.5 3 0 3.5 412 13 5 2 100 6 0 7 42 36 4.9 0 2 291 3 10 411 210 85 510 1 610 42 123.7 290 0 0.5 362.5 12 434 2 90 540 640 42.0 310 2 3.5 398 12 474 0 95 0 1 0 42 193.0 3 0 3.5 412 551 0 105 6 0 790 42 36 2.0 290 0 0 379.5 12 434 2 90 540 640 42 146.5 310 2 3.5 398 12 474 0 95 0 1 0 42 193.0 3 0 3.5 412 13 5 2 100 6 0 7 42 36 2.0 3 310 363 442.5 22 591 0 110 710 190 8 42 36 310.0 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 31

FOUR-BOLT SNTD HOUSINGS FOR TAPERED BORE BEARINGS Labyrinth Seal Taconite Seal Continued from previous page. Shaft Dia. Housing Bearing Locating Rings (1) d O.D. x Width Quantity Locating Rings Required for Fixed Adapter Sleeve (2) Labyrinth Seal (3) Taconite Seal (3) End Cover (3) mm 0 2 0 SNTD 52 252K SR400X22 2 OH52H LO52 TA52 EC52 SNTD 3152 23152K SR440X10 2 OH3152H LO52 TA52 EC52 SNTD 64 22252K SR4X25.5 2 OH3152H LO64/0 TA64/0 EC64 SNTD 34 222K SR540X15.5 2 OH22H LO64/0 TA64/0 EC64 SNTD 56 256K SR4X10 6 OH56H LO56 TA56 EC56 SNTD 3156 23156K SR4X10 2 OH3156H LO56 TA56 EC56 SNTD 22256K SR0X25 2 OH3156H LO/2 TA/2 EC SNTD 2K SR4X25 2 OHH LO TA EC SNTD 2K SR0X10 2 OHH LO TA EC SNTD 34 222K SR540X 2 OHH LO64/0 TA64/0 EC64 0 SNTD 64 SNTD 34 SNTD 38F 4K 234K 224K SR4X10 SR540X10 SR5X 6 2 2 OH64H OH34H OH34H LO64 LO64 LO68/0 TA64 TA64 TA68/0 EC64 EC64 EC68 3 340 3 3 SNTD 68 8K SR5X 4 OH68H LO68 TA68 EC68 SNTD 38F 238K FIXED HOUSING - OH38H LO68 TA68 EC68 SNTD 38L 238K FLOAT HOUSING - OH38H LO68 TA68 EC68 SNTD 72 272K SR540X 4 OH72H LO72 TA72 EC72 SNTD 3172F 23172K FIXED HOUSING - OH3172H LO72 TA72 EC72 SNTD 3172L 23172K FLOAT HOUSING - OH3172H LO72 TA72 EC72 SNTD F 22272K FIXED HOUSING - OH3172H LO/340 TA/340 EC SNTD L 22272K FLOAT HOUSING - OH3172H LO/340 TA/340 EC SNTD 76F 276K FIXED HOUSING - OH76H LO76 TA76 EC76 SNTD 76L 276K FLOAT HOUSING - OH76H LO76 TA76 EC76 SNTD 3176F 23176K FIXED HOUSING - OH3176H LO76 TA76 EC76 SNTD 3176L 23176K FLOAT HOUSING - OH3176H LO76 TA76 EC76 SNTD F 2K FIXED HOUSING - OHH LO TA EC SNTD L 2K FLOAT HOUSING - OHH LO TA EC SNTD F 2K FIXED HOUSING - OHH LO TA EC SNTD L 2K FLOAT HOUSING - OHH LO TA EC (1) Locating rings = sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units TIMKEN SNT SPLIT PLUMMER BLOCKS

00 AND 3100 SERIES (CONTINUED) Housing Dimensions 4 Bolts Req d Housing Mass A A 1 A 2 A 3 C H H 1 H 2 J J 1 L N N 1 G mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg 310 2 3.5 398 12 473 0 95 0 1 0 42 3.6 3 0 3.5 412 13 5 2 100 6 0 7 42 36 2.0 3 310 362.5 442 22 590 0 110 710 190 8 42 36 3.7 3 3 383 462.5 23 631 3 115 7 0 8 42 36 346.0 3 0 3.5 412 13 5 2 100 6 0 7 42 36 4.9 3 0 3.5 412 551 0 105 6 0 790 42 36 2.0 3 310 363 442.5 22 591 0 110 710 190 8 42 36 310.0 3 0 3.5 412 5 0 105 6 0 790 42 36 7.8 3 310 363 442.5 22 591 0 110 710 190 8 42 36 310.0 3 3 383 462.5 23 631 3 115 7 0 8 42 36 346.0 3 3 400 310 3 3 362.5 383 412 442 462.5 491.5 22 23 25 590 631 675 0 3 340 110 115 1 710 7 810 190 0 2 8 8 9 42 42 42 36 36 36 3.7 346.0 4.5 3 3 382.5 462 23 6 3 115 7 0 8 42 36 389.5 400 3 412 491.5 25 675 340 1 810 2 9 42 36 4.5 400 3 412 491.5 25 675 340 1 810 2 9 42 36 429.5 3 3 381.5 461 23 6 3 115 7 0 8 42 36 349.7 400 3 412 491.5 695 3 1 840 2 1000 42 36 458.0 400 3 412 491.5 695 3 1 840 2 1000 42 36 454.0 4 390 442 521.5 775 3 125 9 0 11 48 42 595.0 4 390 442 521.5 775 3 125 9 0 11 48 42 595.0 400 3 412 491.5 675 340 1 810 2 9 42 36 477.4 400 3 412 491.5 675 340 1 810 2 9 42 36 477.4 400 3 412 491.5 715 3 1 8 2 1040 42 36 487.0 400 3 412 491.5 715 3 1 8 2 1040 42 36 484.0 400 3 412 491.5 695 3 1 840 2 1000 42 36 457.3 400 3 412 491.5 695 3 1 840 2 1000 42 36 457.3 4 390 442 521.5 775 3 125 9 0 11 48 42 595.0 4 390 442 521.5 775 3 125 9 0 11 48 42 595.0 Continued on next page. TIMKEN SNT SPLIT PLUMMER BLOCKS 33

FOUR-BOLT SNTD HOUSINGS FOR TAPERED BORE BEARINGS Labyrinth Seal Taconite Seal Continued from previous page. Shaft Dia. Housing Bearing Locating Rings (1) d O.D. x Width Quantity Locating Rings Required for Fixed Adapter Sleeve (2) Labyrinth Seal (3) Taconite Seal (3) End Cover (3) mm 400 410 4 4 4 0 SNTD 84F 284K FIXED HOUSING - OH84H LO84 TA84 EC84 SNTD 84L 284K FLOAT HOUSING - OH84H LO84 TA84 EC84 SNTD 34F 234K FIXED HOUSING - OH34H LO84 TA84 EC84 SNTD 34L 234K FLOAT HOUSING - OH34H LO84 TA84 EC84 SNTD 88F 288K FIXED HOUSING - OH88H LO88 TA88 EC88 SNTD 88L 288K FLOAT HOUSING - OH88H LO88 TA88 EC88 SNTD 38F 238K FIXED HOUSING - OH38H LO88 TA88 EC88 SNTD 38L 238K FLOAT HOUSING - OH38H LO88 TA88 EC88 SNTD 92F 292K FIXED HOUSING - OH92H LO92 TA92 EC92 SNTD 92L 292K FLOAT HOUSING - OH92H LO92 TA92 EC92 SNTD 3192F 23192K FIXED HOUSING - OH3192H LO92 TA92 EC92 SNTD 3192L 23192K FLOAT HOUSING - OH3192H LO92 TA92 EC92 SNTD 96F 296K FIXED HOUSING - OH96H LO96 TA96 EC96 SNTD 96L 296K FLOAT HOUSING - OH96H LO96 TA96 EC96 SNTD 3196F 23196K FIXED HOUSING - OH3196H LO96 TA96 EC96 SNTD 3196L 23196K FLOAT HOUSING - OH3196H LO96 TA96 EC96 SNTD /0F 2/0K FIXED HOUSING - OH/0H LO/0 TA/0 EC/0 SNTD /0L 2/0K FLOAT HOUSING - OH/0H LO/0 TA/0 EC/0 SNTD /5F 2/5K FIXED HOUSING - OH/5H LO/5 TA/5 EC/5 SNTD /5L 2/5K FLOAT HOUSING - OH/5H LO/5 TA/5 EC/5 (1) Locating rings = sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 34 TIMKEN SNT SPLIT PLUMMER BLOCKS

00 AND 3100 SERIES (CONTINUED) Housing Dimensions 4 Bolts Req d A A 1 A 2 A 3 C H H 1 H 2 J J 1 L N N 1 G Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg 400 3 412 491.5 755 3 1 8 2 1040 42 36 597.8 400 3 412 491.5 755 3 1 8 2 1040 42 36 597.8 4 4 472 551.5 810 410 1 1000 2 11 48 42 9.0 4 4 472 551.5 810 410 1 1000 2 11 48 42 9.0 4 390 442 521.5 775 3 125 9 0 11 48 42 671.7 4 390 442 521.5 775 3 125 9 0 11 48 42 671.7 4 4 472 551.5 8 4 1 10 2 12 48 42 751.0 4 4 472 551.5 8 4 1 10 2 12 48 42 751.0 4 4 472 551.5 810 410 1 1000 2 11 48 42 788.8 4 4 472 551.5 810 410 1 1000 2 11 48 42 788.8 4 440 482 561.5 8 440 145 10 2 10 48 42 859.0 4 440 482 561.5 8 440 145 10 2 10 48 42 859.0 4 4 472 553 810 410 1 1000 2 11 48 42 699.6 4 4 472 553 810 410 1 1000 2 11 48 42 699.6 4 440 482 563 9 4 155 1110 2 13 56 48 976.5 4 440 482 563 9 4 155 1110 2 13 56 48 976.5 4 4 472 551.5 8 4 1 10 2 12 48 42 5.5 4 4 472 551.5 8 4 1 10 2 12 48 42 5.5 4 440 482 561.5 9 4 155 1110 2 13 56 48 976.5 4 440 482 561.5 9 4 155 1110 2 13 56 48 976.5 TIMKEN SNT SPLIT PLUMMER BLOCKS

FOUR-BOLT SNTD HOUSINGS FOR CYLINDRICAL BORE BEARINGS The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Housings shown are furnished in ductile iron. Housings with the F suffix are manufactured for fixed bearings. Those with the L suffix are float position housings. A 2 A A 2 A A 3 A 3 d 2 d 2 d 2 d 2 d 1 d 1 d 1 d 1 C C C C Labyrinth Seal Taconite Seal Quantity - Typically Shaft Dia. Housing Bearing Locating Rings (1) required for this bearing/housing da db OD x Width configuration Labyrinth Seal (3) Taconite Seal (3) End Cover (3) mm mm 1 1 SNTD 3134 2 SR0X7.5 2 LO34 TA34 EC34 0 SNTD 3136 2 SR0X7 2 LO36 TA36 EC36 1 1 SNTD 3138 223 SR3X8 2 LO38 TA38 EC38 0 0 1 190 0 2 SNTD 38 SNTD 38 SNTD 3 SNTD 40 SNTD 48 SNTD 48 SNTD 56 222 2 223 22234 22334 2 22340 SR290X17.5 SR290X5.5 SR340X9 SR310X SR3X10 SR3X21 SR4X14 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 2 2 2 2 2 2 2 LO38/0 LO38/0 LO40 LO40/190 LO48/190 LO48 LO56/2 TA38/0 TA38/0 TA40 TA40/190 TA48/190 TA48 TA56/2 2 0 SNTD 3156 22344 SR4X10.5 2 LO56/0 TA56/0 EC52 0 2 SNTD 22348 SR0X12.5 2 LO/2 TA/2 EC 2 0 SNTD 64 22252 SR4X25.5 2 LO64/0 TA64/0 EC64 2 290 SNTD 34 222 SR540X15.5 2 LO64/290 TA64/290 EC64 0 310 SNTD 38L 2 SR5X17.5 2 LO68/310 TA68/310 EC68 3 390 SNTD F 22272 SR6X25 2 LO/390 TA/390 EC EC38 EC38 EC40 EC40 EC48 EC48 EC56 36 TIMKEN SNT SPLIT PLUMMER BLOCKS

00 AND 3100 SERIES Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Grease hole fittings and plugs use 1 4 BSPT thread size Additional grease fittings are supplied for flexible configurations. Seal sleeve for d a shaft to be supplied by customer and should have same O.D. as d b. Housing Dimensions 4 Bolts Req d Housing Mass A A1 A2 A3 C H H1 H2 J J1 L N1 N G mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg 2 0 3 0 14 333 1 4 100 510 34 75.0 0 190 252.5 314.5 15 3 0 75 4 110 5 34 92.0 2 210 271.5 333.5 10 375 190 4 1 5 34 112.0 0 0 0 2 290 290 3 190 190 2 210 0 0 0 252 252 291.5 271 0 0 3.5 314 314 8.5 338 379.5 379.5 412 15 15 10 10 12 12 13 4 4 411 375 434 434 5 0 0 210 190 2 2 2 75 75 85 90 90 100 3 0 3.5 412 551 0 105 6 0 790 42 36 2.0 3 310 363 442.5 22 591 0 110 710 190 8 42 36 310.0 3 3 0 310 3.5 362.5 412 442 13 22 5 590 2 0 100 110 3 3 383 462.5 23 631 3 115 7 0 8 42 36 346.0 400 3 412 491.5 25 675 340 1 810 2 9 42 36 429.5 4 390 442 521.5 775 3 125 9 0 11 48 42 595.0 4 4 510 4 540 540 6 6 710 110 110 1 1 0 0 190 5 5 610 5 640 640 7 7 8 34 34 42 34 42 42 42 42 42 36 36 36 85.9 85.9 1.0 102.6 146.5 146.5 4.9 2.0 3.7 TIMKEN SNT SPLIT PLUMMER BLOCKS 37

SNTN HOUSINGS FOR TAPERED BORE BEARINGS SNTN 00 Light Series cast iron housings are designed for large spherical roller bearings (110 - mm tapered bore) used in light duty applications. The part numbers for ordering split plummer block housings and components are listed in the table below. Double-Lip Seal V-Ring Seal Labyrinth Seal Taconite Seal Shaft Dia. Housing Bearing Locating Rings (1) Adapter Sleeve (2) Double-Lip Seal (3) V-Ring Seal (3) Labyrinth Seal (4) Taconite Seal (4) End Cover (4) d mm O.D. x Width 110 SNTN 2K SR0X12 H TSNG5 VR5 LO5 TA5 EC5-6 115 SNTN 2K SR0X13.5 H TSNG5 VR5 LO5 TA5 EC5 125 SNTN 2K SR210X13 H TSNG5 VR5 LO5 TA5 EC5 1 SNTN 2K SR225X15 H TSNG5 VR5 LO5 TA5 EC5 SNTN 2K SR0X15 H TSNG5 VR5 LO5 TA5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Adapter sleeve assembly includes one sleeve, one locknut and one lockwasher. (3) Double-lip and V-ring seals sold two seals per box. (4) Labyrinth, taconite seal and end cover sold one seal per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 38 TIMKEN SNT SPLIT PLUMMER BLOCKS

00 LIGHT SERIES Each housing includes the housing cap, housing base and cap bolts. Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Grease hole fittings and plugs use 1 4 BSPT thread size. Housings shown are furnished in cast iron. Housing Dimensions A A 1 A 2 A 3 H H 1 H 2 J L N N 1 G 2 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm kg 0 110 0 0 2 112 40 3 3 17.0 175 1 0 5 2 125 45 3 410.0 175 1 195 255 2 45 3 410 25.0 190 1 215 5 290 1 3 445.0 190 1 215 2 297 1 390 4 36.0 TIMKEN SNT SPLIT PLUMMER BLOCKS 39

SNTN HOUSINGS FOR CYLINDRICAL BORE BEARINGS SNTN 00 Light Series cast iron housings are designed for large spherical roller bearings (1 175 mm cylindrical bore) used in light duty applications. The part numbers for ordering split plummer block housings and components are listed in the table below. Each housing includes the housing cap, housing base and cap bolts. Double-Lip Seal V-Ring Seal Labyrinth Seal Shaft Dia. Housing Bearing Locating Rings (1) Double-Lip Seal (2) V-Ring Seal (2) Labyrinth Seal (3) End Cover (3) da db O.D. x Width mm mm 1 1 SNTN SNTN 2 0 SR0X12 SR0X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5-6 EC5-6 1 145 SNTN SNTN 2 0 SR0X13.5 SR0X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 155 SNTN SNTN 2 0 SR210X13 SR210X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 1 5 SNTN SNTN 2 0 SR225X15 SR225X5.5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 0 175 SNTN SNTN 2 0 SR0X15 SR0X5 TSNG2 TSNG2 VR2 VR2 LO2 LO2 EC5 EC5 (1) Locating rings = two required for fixed position, sold one piece per box. (2) Double-lip and V-ring seals sold two seals per box. (3) Labyrinth and end cover sold one per box. 3D CAD and 2D drawings available at http://cad.timken.com/category/snt-housed-units 40 TIMKEN SNT SPLIT PLUMMER BLOCKS

00 LIGHT SERIES Specify bearing suffix W33 for center lubrication of groove and holes, and use the housing center port for the grease fitting. Grease hole fittings and plugs use 1 4 BSPT thread size. Assemblies shown are furnished in cast iron. Seal sleeve for d a shaft to be supplied by customer and should have same O.D. as d b. Housing Dimensions A A1 A2 A3 H H1 H2 J L N N1 G 2 Bolts Req d Housing Mass mm mm mm mm mm mm mm mm mm mm mm mm kg 0 0 175 175 175 175 190 190 190 190 110 110 1 1 1 1 1 1 1 1 0 0 0 0 195 195 215 215 215 215 0 0 5 5 255 255 5 5 2 2 2 2 2 2 2 2 290 290 297 297 112 112 125 125 1 1 1 1 40 40 45 45 45 45 3 3 3 3 3 3 3 3 390 390 3 3 410 410 410 410 445 445 4 4 17.0 17.0.0.0 25.0 25.0.0.0 36.0 36.0 TIMKEN SNT SPLIT PLUMMER BLOCKS 41

TIMKEN HOUSED UNITS...SOLUTIONS HOUSED IN STRENGTH. Split Cylindrical Bearing SNT/SAF Split Plummer (Pillow) Blocks Spherical Roller Bearing Solid Block Type E Tapered Roller Bearing Fafnir and U Series Ball Bearing Applications Split-to-the-shaft design is ideal for trapped applications in highservice cost locations Large process equipment and heavy material handling where access and contamination present challenges Process equipment and bulk material handling where shock loads, heavy contamination and misalignment are issues Process equipment and bulk material handling where heavy contamination and high axial loads are issues Material handling equipment with high speeds and/or light loads Bearing Insert Precision cylindrical roller bearing with machined brass cage and profiled rolling elements High-performance spherical roller bearing with tapered bore or straight bore options High-performance spherical roller bearing with six shaft locking options Tapered roller bearing with enhanced internal geometries Wide-inner-ring ball bearings provide improved shaft support and increased bearing life Shaft Size Range 40 mm to 0 mm; 1 9 in. to in.; Larger sizes available mm to 5 mm; 1 3 8 in. to 19 1 2 in; Larger sizes available mm to 0 mm; 1 7 in. to 7 in.; Larger sizes available mm to 125 mm; 1 3 in. to 5 in. 12 mm to 90 mm; 1 2 in. to 3 15 in. Housing Split design available in cast iron, ductile iron and cast steel Split, two-piece design Cast iron (cast steel and ductile iron available) Solid block, one-piece design Cast steel Machined feet for consistent housing location Solid block, onepiece design Cast iron Solid block, onepiece design Cast iron Seal Options Seven seal styles, including Kevlar packing seal and aluminum triple labyrinth SNT options include double-lip, labyrinth, V-ring, and taconite SAF comes standard with labyrinth seals, options include Timken Guard (superior protection against contamination) and taconite Six seal options Three triple-lip seal options (superior protection against contamination) Two double-lip seal options One labyrinth seal option (for high-speed applications) Auxiliary steel end covers available High-performance seal (standard) designed for optimized lip contact Fafnir Ball Bearing Single lip (standard) Triple lip (superior protection against contamination) Labyrinth (for high-speed applications) U Series Ball Bearing Precision-formed flinger High-performance seal Additional Features Split housing dimensionally interchangeable with SNL/SN/SD and SAF series plummer blocks Compensates for high degree of shaft misalignment Highly effective sealing even in extremely contaminated and wet environments Push/pull-type adapter sleeves available for ease of application Components interchangeable with industry standard designs May be ordered as individual components or an assembly Multiple options to lock bearing to shaft Eccentric lock Set screw lock V-lock Tapered adapter lock Double adjustment nut for fixed-to-float conversions Available with set screw locking Electro-coat paint for additional corrosion protection Enhanced bearing geometries deliver highest dynamic load ratings in the industry Fafnir Ball Bearing Shaft Guard Technology (to ease and simplify installation and removal) Three shaft-locking options: set screw, eccentric and concentric U Series Ball Bearing Steel cage for high temperatures Hardened and ground seal land Benefits Inspection and replacement time dramatically reduced due to split-to-theshaft design Significantly reduces downtime associated with moving equipment to change out a bearing Easy-to-remove cap for bearing inspection Housings may be reused Easily converts from fixed to float in the field High-performance Timken spherical roller bearing runs cooler for longer bearing life Quicker installation time than split housings Easily converts between fixed and float positions after installation High-performance Timken spherical roller bearing runs cooler for longer bearing life Quicker installation time than split housings Increased useful bearing life and load capacities Double-lip seal provides industry-leading protection against contamination Corrosion-resistant options Variety of high-strength housing designs Easy installation and removal Improves installation safety Timken housed units are interchangeable with common industry designs. Contact your Timken sales engineer for more information. Kelvar is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates. 42 TIMKEN SNT SPLIT PLUMMER BLOCKS

INDUSTRIES AND APPLICATIONS Power Generation (Coal) Mining Aggregate/Cement Metal Mills Pulp & Paper/Sawmills/Forestry Water Treatment Food Processing Warehousing Movable Bridges/Structures Industrial Fans/Blowers CALL ON TIMKEN For your nearest Timken sales representative, visit www.timken.com. TIMKEN SNT SPLIT PLUMMER BLOCKS 43