Installation, Operation and Maintenance Instructions

Similar documents
Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

Innovative suction chamber design

Installation, Operation and Maintenance Instructions

Waste Water Solutions

Cake Pump Maintenance Made Easy!

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

Widethroat W Range W ᓔষ

Product Dimensions MODEL MODEL

Installation, Operation and Maintenance Instructions

Features & Benefits. A competitively priced progressing cavity pump, with a compact construction and maximum performance characteristics.

Artificial Lift. Production Automation

Agricultural Water Pumping Systems

Installation, Operation and Maintenance Instructions

Waste Water Solutions

9085_MonoPUmpsLFRangeA4_8pp 18/1/13 14:24 Page 1 LF Range

EZstrip Transfer Pump

Waste Water Solutions

Installation, Operation and Maintenance Instructions

1127_MuncherAm:28146_MuncherUK16ppR10 15/4/08 14:17 Page 1 Muncher Family

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

PRESSURE BOOSTER 150

E Range Heavy Duty Pumps. Benchmark for Reliability

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Domestic Water Supply Pressure Pumps

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

INSTALLATION AND OPERATING INSTRUCTIONS

AL-KO OFF-ROAD PIN COUPLING USERS MANUAL

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

SOLAR DASH CHARGING SYSTEM USER GUIDE

Installation, Operation and Maintenance Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

Installation, Operation and Maintenance Instructions

POSITIVE DISPLACEMENT FLOWMETERS

BRITESTREAM LED FIBREGLASS NICHE POOL LIGHTS

Installation, Operation and Maintenance Instructions

REMOTE CONTROLLED CENTRAL LOCKING SYSTEM. INCLUDES 4 DOOR ACTUATORS. Owner s Operation Manual

AL-KO OFF-ROAD BALL COUPLING USERS MANUAL

AL-KO ESC USER MANUAL

BRITESTREAM SLIM90 FIBREGLASS POOL LIGHT

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

USER GUIDE. PowerRite XT UPS. 400 VA, and 600 VA.

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

MODEL BARE REEL SERIES E

REMOTE CONTROLLED CENTRAL LOCKING. Owner s Operation Manual

FULFLO CARTRIDGE FILTERS

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

TRIMLINE CARTRIDGE FILTERS

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS INSTRUCTION MANUAL

Installation, Operation and Maintenance Instructions

P5510. Users Manual. Pneumatic Comparison Test Pump

SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

EAFM, EAFC & EAFN Filters Installation and Operating Instructions

Installation and Operating Instructions for Davey XP/T & XJ/T Pressure Systems with

Integra / Summer Breeze

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

Mooney* Type 24/24S Restrictor

ROOF BOX INSTRUCTIONS Fitting instructions for Roof Box (EXP1/EXP2)

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER.

SUNTURA SOLAR TRACKER

OPERATOR S MANUAL TWIN REGULATOR LUBRO CONTROL UNIT. Part Number Issue 3 Original Instructions (English)

Medifab AU 1300 b NZ Page 1

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

11265_MONO_UK_Muncher_16pp 21/03/2014 2:56 pm Page 1 MuncherTM Family

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

INSTALLATION AND OPERATING INSTRUCTIONS

The experts in fluid technology

Installation and Operating Instructions for

PRODUCT MANUAL. Heavy Duty Backpack Sprayer 16L

SUPERIOR PERFORMANCE

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Operation & Service Manual

TRIMLINE CARTRIDGE FILTERS

POSITIVE DISPLACEMENT FLOWMETERS

Expanded Metal Walkway

Customer Support

Consumer guide. be brighter. actewagl.com.au/solar

INSTALLATION AND OPERATING INSTRUCTIONS

12 VOLT SOLAR PANEL KITS MONOCRYSTALLINE. P/No. SPP160K

OWNER S MANUAL PRODUCT CODE: 2006T

INSTALLATION: SHALLOW WELL & CENTRIFUGAL

Safe-T-Glide Installation Instructions

SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

HM Series Electric Pumps

INSTALLATION AND OPERATING INSTRUCTIONS

SUNTURA HD SOLAR TRACKER

PRODUCT MANUAL. Backpack Sprayer 12L

Expanded Metal Walkway

Transcription:

English Installation, Operation and Maintenance Instructions Solar Pressure Systems MPA581/5

Contents Warranty 3 Warranty Statement 3 Introduction 4 System Overview 4 Intended Use 4 Warnings 4 Selection 5 Selecting a Pressure System 5 Specifications 6 Mini MPPT Pressure Kit 6 SMC & Power Master Pressure Kit 6 Assembly 7 Assembly of the Pressure Kit 7 Installation 8 Setting up the Pressure System 8 Maintenance 10 Wiring Diagram for Solar Pressure Kits 10 Maintenance Schedule 10 How the System Works 11 Contents Page 2

Warranty 1. The Solar Water Pumping System manufactured by Mono Pumps are covered by warranty for a period not exceeding twenty-four months from purchase. 2. Mono Pumps will make good by repair, or at their option, the replacement of faulty parts under warranty, providing always that: (a) The equipment was correctly installed and properly used in accordance with Mono Pumps Installations and Operating instruction and accepted codes of good engineering practice. (b) (c) (d) The claim for goods under warranty arises solely from faulty design, material or workmanship. The repair is carried out in the Mono factory or by an authorised agent or distributor appointed by Mono Pumps. All freight costs to and from the factory or repair agent are to be paid by the purchaser. 3. In the case of equipment or components which are not of Mono manufacture, but supplied by them, the warranty is limited to that extended by the suppliers or manufacturers of such equipment. (f) Damage to the motor if the motor is found to have been disassembled before being returned to Mono Pumps. (g) Damage caused by running the pump dry. 5. The decision of Mono Pumps in relation to any claims or disputes over warranty is final. 6. The warranty is in lieu of all other warranties and conditions expressed or implied, written or oral, statutory or otherwise, which are hereby negated and excluded. 7. This express warranty does not exclude any conditions or warranty implied by the Trade Practices Act 1974 or separate State laws and in addition to any other right, that the original purchasers or any subsequent purchaser may have at law. In case of claim please contact your Authorised Mono Dealer or contact Mono Pumps (Australia) Pty. Ltd. 4. Mono Pumps warranty does not cover any of the following: (a) Claims for third party liability of damage caused by failure of any of the company s products. (b) Damage caused by abnormal operating conditions, war, violence, storm cataclysm or any other force. (c) Damage caused by the equipment being used for an application for which it is not recommended. (d) Damage caused by sand or abrasive materials, corrosion due to salt water or electrolytic action. (e) Damage to the SMC if the SMC has been opened by removal of the back plate before being returned to Mono Pumps. Warranty Page 3

Introduction System Overview Mono Solar Pressure Systems are comprised of 5 main components: 1 Pressure tank 2 Pressure switch, cable and plug 3 Pressure gauge 4 Mounting bracket 5 Pipe and fittings Two types of Solar Pressure Kits are available. Both kits uses the same steel pressure tank and switch (shown on the right), but differ due to the connection method to the controller. The SUN S0884 uses a two pin plug plug suitable for connecting to a Mono Mini MPPT controller (as used on CP25 Sun-Ray Systems). The second kit, SWP-10065, is fitted with a four pin plug suitable for connection to controllers used on Sun-Sub, Sun-Downer or Large Sun-Ray (other than the CP25) systems. The maximum pressure rating of the metal tank is 70m (pressure is also restricted by the pump used). This pressure is wired to suit a Mono Solar Water Pumping System. The electrical voltages on the float switch outlet of the solar controller is 24 V nominal. This system is not intended to be used with 240 applications. Consult a qualified electrician if modifying this system to use with high voltage applications. To prevent damage to the discharge pipework or the pressure tank, the pressure switch must be set correctly to turn off the pump at a safe working pressure. Do not bypass the pressure switch if the pipework is fitted with a float valve. Intended Use The solar pressure kits are designed for use with Mono Solar Water Pumping Systems. The kits are intended to be used to automatically stop the pump when a remote tank is full of water and restart the pump when the water level in the tank drops. When the tank is in close proximity to the solar pump it is usually more convenient to install a float switch in the tank to control the pump rather than use a pressure kit. Pressure kits should be used when the distance between the pump and tank make it difficult to run electrical cables to a float switch. Warnings Do not use a normal float valve with this pressure kit. Only double acting float valves should be used. Using a normal float valve will prevent the system from functioning correctly. Introduction Page 4 Issued November 2009

Selection Selecting a Pressure System 1. Before purchasing a Pressure System it is necessary to determine the Static Head (H) and Friction Head (F) at the maximum pump flow rate. Convert H and F to kpa by multiplying by 10. 2. The pressure tank must have a pressure rating greater than the H + F + 50 kpa 3. The pressure switch must have adjustable settings for both on pressure and pressure differential. Double Acting Float Valve Storage Tank Mainline Pipe Friction Head - F Pressure Kit Static Delivery Head - H Bore Static Head Solar Pump Selection Page 5

Specifications Mini MPPT Pressure Kit (For use with CP25 Sun-Ray systems only) Mono Part Number SUN S0884 Maximum Pressure 30 metres or 300 kpa (maximum pressure of pump) Mounting Brackets Galvernised Steel angle with U-bolts to suit 100 mm or 125 mm post (post not included in kit) Pipe Connections 1 inch BSP male thread Pressure Switch XMP 0 to 120 m with separate on and differential pressure adjustment, IP54 Pressure Gauge 0 to 800 kpa oil filled Electrical Connection Two pin IP68 plug SMC & Power Master Pressure Kit (For use with Sun-Sub, Sun-Downer and Sun-Ray systems other than the CP25 Sun-Ray.) Mono Part Number SWP-10065 Maximum Pressure 70 metres or 700 kpa (pressure rating of the steel pressure tank) Mounting Brackets Galvernised Steel angle with U-bolts to suit 100 mm or 125 mm post (post not included in kit) Pipe Connections 1 inch BSP female thread Pressure Switch XMP 0 to 120 m with separate on and differential pressure adjustment, IP54 Pressure Gauge 0 to 800 kpa oil filled Electrical Connection Four pin IP68 plug Specifications Page 6

Assembly Assembly of the Pressure Kit Assemble the pressure kit as shown in the pictures on the previous page. Teflon tape should be used on all connections to ensure that the joints are water tight. The pressure switch must be installed in the vertical positions as shown. If the switch is not vertical, water may enter the switch causing premature corrosion. Mount the pressure kit on the array post using the supplied U- bolts. If the array frame does not have a suitable pole, mount the pressure kit on a steel or wooden post. The jumper plug that is supplied with the SMC, Power Master or Mini MPPT can be used to wire into a pressure kit however it is better to keep the Jumper Plug and use a separate plug with the pressure kit. The jumper plug is useful for fault finding the system and bypassing the pressure kit. Jumper Plug (For operation without pressure switch) The float switch plug is assembled as shown below. A wiring diagram for the pressure switch and plug is found at the end of this manual. Float switch plug assembly Assembly Page 7

Installation Setting up the Pressure System 1 Connect the pressure system to the discharge pipework. Refer to the diagram below. 2 Install the four-pin jumper plug in the SMC socket labelled FLOAT SWITCH. This will allow the system to start regardless of the pressure switch settings. (If a jumper plug is not available, plug the pressure switch plug into the SMC. It may be necessary to make adjustments to the pressure switch to make the system start.) 3 If the Double Acting Float Valve is already fitted at the end of the discharge pipe, make sure it is in the open position. If the Double Acting Ball Valve has not been fitted leave it disconnected until the pressure switch has been correctly set. 4 Turn on the system. The switch will need to be set at midday to ensure that the flow rate is at its peak. 5 When water is flowing out of the discharge end of the pipework, record the pressure from the gauge at the pressure tank. This will be the Total Pressure H + F. 6 Turn off the system and record the pressure on the pressure gauge. This is the Static Pressure, H. 7 Empty the discharge pipe by unscrewing connection A. 8 Set the pressure in the air tank to the Static Head pressure, H + 50 kpa. The air pressure must be adjusted with pipe A disconnected. Summary of Pressure Settings On Pressure = H + 50 kpa (5 m). Off Pressure = H + F + 50 kpa (5 m). Tank Air Pressure = On Pressure. Off Pressure must be lower than the pressure rating of the tank. Note: 1 metre = 10 kpa B Ball or gate valve Optional Non- Return Valve Pressure Tank To Tank Pressure Gauge Pressure Switch A Bore Cap Installation Page 8

Installation 9 Remove the jumper plug from the SMC and plug the pressure switch into the SMC. Reconnect pipe A. 10 Disconnect the discharge pipe after the ball valve at point B. 11 Open the ball valve and turn on the pump. 12 Close the ball valve until the pressure gauge reads the total pressure H + F + 50 kpa as found in step 5. Adjust the Cut Off pressure screw on the pressure switch so that the pump turns off at H + F + 50 kpa. (It may be necessary to increase the Cut On pressure setting). Note: Each turn of the screw equals approximately 5 kpa. 13 Open the ball valve and allow the system to restart, test the cut off setting by closing the ball valve. The pump should stop. 14 Open the ball valve slightly so that the pressure falls slowly. Note the pressure at which the pump turns on. Adjust the Cut On screw on the pressure switch so that the system restarts at H + 50 kpa. 15 Re-check that the system is turning off at the correct pressure. 16 The pressure switch is now set. Turn off the system and reconnect the discharge pipe. Fit the Double Acting Ball Valve at the tank. 17 Open the ball valve and turn the system on. 18 Check for correct operation of the system by manually opening and closing the Double Acting Ball Valve at the tank. Differential Pressure Adjustment Cut Off Pressure Adjustment Switch (Use Normally Closed Contacts) Pressure switch with cover removed Installation Page 9

Maintenance Wiring Diagram for Solar Pressure Kits Maintenance Schedule Every 3 Months: Note incorrect connection of float switch plug will damage the solar motor controller electronics Float switch plug. Viewed from top of pins Note: Some systems are fitted with two pin float switch plugs. 1 2 3 4 Check the air pressure in the tank. The air pressure must be checked with the pipe A disconnected and the system off. Check for correct operation of the pressure switch by manually operating the Double Acting Ball Valve. Every 12 Months: With the system off and the pipe A disconnected from the pump discharge pipework, remove the pressure switch and check the hole in the base of the switch for obstructions. Clean out the switch and pipework to ensure trouble free operation of the switch. Normally Closed Contact Of The Pressure Switch Maintenance Page 10

Maintenance Pressure Diagram for a Typical System 35 Pressure at Pressure Switch [Metres] 30 25 20 15 10 5 A B C D E F G H I 0 Time How the System Works A. When the pump is turned on for the first time the discharge pipe is empty. The pressure rises as water fills the pipe due to the Static Head and Friction Losses. B. Once the pipe is full and water is flowing into the tank the pressure stabilizes. The system will operate in this condition until the tank is full. Because the flow rate changes on a solar system throughout the day the Friction Head will also change. When setting up a pressure system the maximum daily flow rate should be used for the friction loss calculations. E. When the Double Acting Ball Valve opens the pressure will fall as water flows out of the pressure tank. When the pressure falls to the On Pressure of the Pressure Switch the pump will restart. F. The pressure will quickly rise again to the Static Head Pressure + the Friction Loss Pressure. G. The cycle repeats. See B above. H. See C above. II. See D above. C. Once the tank is full the Double Acting Ball Valve will close. Water will then flow into the pressure tank. As the pressure tank fills the pressure rises until the pressure switch cuts out. This occurs at the Off Pressure, which is 30 meters in the example above. D. The system pressure will remain at the Off Pressure until the tank empties and the Double Acting Ball Valve opens or the pressure falls due to leaks in the valve or pipe-fittings. Maintenance Page 11

Europe Mono Pumps Ltd, Martin Street, Audenshaw Manchester, M34 5JA, England T. +44 161 339 9000 E. info@mono-pumps.com D.M.I EST, 56, rue du Pont 88300 Rebeuville, France T. +33 3 29 94 26 88 E. dmi-est@dmi-est.fr Americas Monoflo Inc., 10529 Fisher Road Houston, Texas 77041, USA T. +1 713 980 8400 E. inquire@monoflo.com Monoflo S.A., Ing Huergo 2239 (1842) Monte Grande Pcia. de Buenos Aires, Argentina T. +54 11 4290 9940/50 E. info@monoflo.com.ar Monoflo Canada, 6010 53rd Ave Alberta, Lloydminster T9V2T2, Canada T: + 1 780 875 5584 E: info@monoflo.com.ar Asia Mono Pumps Ltd, No. 500 YaGang Road Lujia Village, Malu, Jiading District Shanghai 201801, P.R. China T. +86 21 5915 7168 E. monoshanghai@nov.com Australasia Mono Pumps (Australia) Pty Ltd 338-348 Lower Dandenong Road Mordialloc, Victoria 3195, Australia T. 1800 333 138 E. ozsales@monopumps.com Mono Pumps (New Zealand) Ltd 35-41 Fremlin Place, Avondale Auckland, 1026, New Zealand T. +64 9 829 0333 E. info@monopumps.co.nz Melbourne T. 03 8587 4303 F. 03 8587 4388 Sydney T. 02 8536 0900 F. 02 9542 3649 Brisbane T. 07 3350 4582 F. 07 3350 3750 Adelaide T. 08 8447 8333 F. 08 8447 8373 Perth T. 08 9479 0444 F. 08 9479 0400 Darwin T. 08 8931 3300 F. 08 8931 3200 Kalgoorlie T. 08 9022 4880 F. 08 9022 3660 Christchurch NZ T. +64 3 341 8379 F. +64 3 341 8486 www.monopumps.com Mono Pumps Limited November 2009 Literature reference: MPA581-5 Mono is a registered trademark of Mono Pumps Limited. seepex is a registered trademark of seepex Seeberger GmbH + Co. NEMO, NM and NE are registered trademarks of Erich Netzsch GmbH & Co Holding KG. NETZSCH is a registered trademark of NETZSCH Mohnopumpen GmbH. Mono Pumps Limited is not an authorised distributor of parts and services for the products of Seeberger GmbH, Allweiler, NETZSCH Mohnopumpen GmbH, PCM, Robbins & Myers or Orbit and Mono Pumps Limited products are not associated with, endorsed by, or sponsored or manufactured by these companies. Produced on recycled paper