PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Similar documents
2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

PAHT pump PAHT X

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

APP S 674 pumps APP S / APP S APP S

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement.

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Data sheet APP

Nessie High-Pressure Pumps for technical water, type PAH

521B0850 DKCFN.PD.013.FA5.02

Water pumps for Desalination APP 16-22

521B0850 DKCFN.PD.010.FA2.02

PAH / PAHT / PAHT G pumps

521B0851 DKCFN.PD.010.FB1.02

Energy Recovery Device isave 21-40

APP pump instruction APP 21-43

APP pump instruction APP and APP 16-22

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

APP S pumps APP S / APP S / APP S 21-38

Energy Recovery Device isave 21-40

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

Series TMM Axial Piston Motor. Technical Information

Changing pistons APP and APP 16-22

Disassembling and assembling PAH , PAHT and PAHT G

Filter solutions for Danfoss PAH, APP and CLP pumps

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

ATEX instruction APP S 674 pumps APP S , APP S and APP S

Changing pistons APP 21-43

TMVW Orbital Motors. Technical Information

OML and OMM Orbital motors. Technical Information

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

OMEW Standard and with Low Speed Option. Orbital Motors. Technical Information

Output flow In l/min at 1500 min

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Series 20 Axial Piston Motors. Technical Information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulic Pump Series VP1 Variable Displacement

Quality Products for Mechanical & Fluid Power. TQ & TV Series VANE PUMPS

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Fixed Displacement Motor AA2FM (A2FM)

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Series 20 Axial Piston Motors. Technical Information

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

B e n t a x i s hydraulic motors. MSeries

B e n t a x i s hydraulic motors. MSeries

Axial Piston Fixed Pump A17FNO Series 10

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Variable displacement axial piston pump type V30D

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

2.4 HEAVY DUTY SERIES

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

External gear motor High Performance AZMB

SCM DIN. Other advantages:

TAP Gear Pumps Technical Information Tap Gear Pumps Standard Flange. OpenCircuitGear. Installation dimensions. Specification Data

SCM M2. Other advantages:

GMP-Type. Key Features: Integrated Motor-Pump Units

M7X / M7V Series. Swash Plate Type Axial Piston Motor. Precision Machinery Company

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Orbital Motors DH and DS

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

INSTRUCTIONS Servicing PAH

Oil pump type RSA. Catalogue 1. Burner Components

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

External Gear Pumps Series F

Pressure Relief Valve DB12 CE

AXIAL PISTON MOTORS SHMF

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

MKD04 COMPACT MOTORS

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

1.3 HIGH PRESSURE SERIES

Technical Information Series 45 G Frame powersolutions.danfoss.com

THE PRODUCTION LINE OF PONAR WADOWICE

Assisted lift operated 2/2-way solenoid valves Type EV251B

Axial Piston Fixed Motor A2FM

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

MOTOR SCM ISO

Transcription:

Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet PAHT 2-308 pumps / PAHT G 2-308 pumps / ATEX PAHT G pump danfoss.high-pressurepumps.com

Table of Contents 1. Introduction...2 2. Benefits...3 3. Application examples...3 4. Technical data...4 4.1 PAHT 2-12.5...4 4.2 PAHT 20-32...5 4.3 PAHT 50-90...6 4.4 PAHT 256-308...7 5. Flow...8 5.1 PAHT 2-6.3 typical flow curves at max pressure...8 5.2 PAHT 10-12.5 typical flow curves at max pressure...9 5.3 PAHT 20-32 typical flow curves at max pressure...10 5.4 PAHT 50-90 typical flow curves at max pressure....11 5.5 PAHT 256-308 typical flow curves at max pressure...12 6. Motor requirements....13 7. Installation...14 7.1 Filtration...14 7.2 Noise...14 7.3 Open-system design...15 7.4 Closed-system design...16 8. Dimensions and connections....17 8.1 PAHT 2-6.3...17 8.2 PAHT 10-12.5...18 8.3 PAHT 20...19 8.4 PAHT 25-32...20 8.5 PAHT 50-90...21 8.6 PAHT 256-308...22 9. Service...23 1. Introduction The Danfoss range of PAHT and PAHT G highpressure pumps is specifically designed for use with technical water such as: Ultra-pure water that has undergone multiple reverse osmosis processes De-ionized water Demineralized water Danfoss PAHT pumps are positive displacement pumps, with axial pistons that move a fixed amount of water in each cycle. Flow is proportional to the number of input shaft revolutions (rpm). Unlike centrifugal pumps, they produce the same flow at a given speed independently of no matter what the discharge pressure. The range of PAHT G pumps is based on the standard PAHT pump series. The PAHT G pumps are made with extra coatings that reduce the wear of the pump. This coating is particularly important for pumps used in gas turbine applications or other similar applications where the wear of the pumps is higher due to the ultra pure water quality. The next pages will cover both PAHT, PAHT G and PAHT G ATEX pumps with the name PAHT pumps. 2 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

Below sectional drawing is an example of a PAHT pump. 1: Mounting flange 2: Shaft seal 3: Connecting flange 4: Port plate 5: Valve plate 6: Retainer plate 7: Swash plate 8: End cap 9: Spring 10: Piston 11: Cylinder barrel 12: Housing with bearing 2. Benefits Zero risk of lubricant contamination: - Oil lubricants are replaced with the pumped medium, water, so there is no contamination risk from the pump. Low maintenance costs: - Efficient design and all-stainless steel construction ensure exceptionally long lifetime. When Danfoss specifications are met, service intervals of up to 8,000 hours can be expected. Service is easy, and can be carried out on site due to the simple design and few parts. Low energy costs: - The highly efficient axial piston design provides the lowest energy consumption of any comparable pump on the market. Easy installation: - The lightest and most compact design available. - Pump can be installed horizontally or vertically. - No pulsation dampeners necessary due to extremely low-pressure pulsation. - Powered by electric motors or combustion engines. - Suitable for both boosted inlet pressure and water supply from a tank. - No need for cooling circuits due to very high mechanical efficiency. Certified quality: - Fulfills the stringent hygiene requirements, VDI 6022, HACCP. - Certificates: ISO 9001, ISO 14001 ATEX available on PAHT G, API available on request 3. Application examples High-pressure cleaning with ultra-pure water, as used in the manufacturing of flat-panel displays and many other electronic products. High-pressure cleaning with ultra-pure water, as used in the manufacturing of parts for the automobile industry. Adiabatic cooling systems to replace or supplement standard A/C systems in server rooms and factories. Humidification in office buildings, electronic component manufacturing, dairies, greenhouses, etc. Dust suppression and odor control systems, for example in paper, textile and wood production. Reduction of NOx emissions in diesel engines and gas turbines. Gas turbine by inlet fogging and fuel wash systems. 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 3

4. Technical data 4.1 PAHT 2-12.5 Pump size 2 3.2 4 6.3 10 12.5 Code number PAHT 180B0031 180B0077 180B0030 180B0029 180B0032 180B0033 Code number PAHT G 180B1003 180B1004 180B1005 180B1006 180B1007 180B1008 Code number ATEX PAHT G 180B6131 180B6177 180B6130 180B6129 180B6132 180B6133 Housing material AISI 304 AISI 304 AISI 304 AISI 304 AISI 304 AISI 304 Geometric displacement Pressure Min. outlet pressure Max. outlet pressure Inlet pressure, continuous Max. inlet 1) pressure, peak cm³/rev 2 3.2 4 6.3 10 12.5 in³/rev 0.12 0.20 0.24 0.38 0.61 0.76 barg 30 30 30 30 30 30 psig 435 435 435 435 435 435 barg 100 100 100 100 140 140 psig 1450 1450 1450 1450 2031 2031 barg 0-4 0-4 0-4 0-4 0-4 0-4 psig 0-58 0-58 0-58 0-58 0-58 0-58 barg 4 4 4 4 4 4 psig 58 58 58 58 58 58 Speed Min. speed rpm 1000 1000 1000 1000 1000 1000 Min. speed, continuous rpm 1000 1000 1000 1000 1000 1000 Max. speed rpm 3000 3000 3000 3000 2400 2400 Typical flow - Flow curves available in section 5 1000 rpm at l/min 0.7 2.0 3.0 5.5 7.6 10.2 1500 rpm at 1200 rpm at 1800 rpm at Typical motor size 1500 rpm at 1800 rpm at Torque at max. outlet pressure Media temperature Ambient temperature l/min 1.7 3.6 5.0 8.6 12.6 16.5 gpm 0.3 0.7 1.0 1.8 2.5 3.3 gpm 0.6 1.2 1.6 2.7 4.0 5.3 kw 50 Hz hp 60 Hz 0.75 1.1 1.5 2.2 4.0 5.5 1.0 1.5 2.0 3.0 7.5 7.5 Nm 4.4 6.7 8.1 12.4 25.6 31.7 lbf-ft 3.2 4.9 6.0 9.2 18.9 23.4 C 2-50 2-50 2-50 2-50 2-50 2-50 F 37-122 37-122 37-122 37-122 37-122 37-122 C 0-50 0-50 0-50 0-50 0-50 0-50 F 32-122 32-122 32-122 32-122 32-122 32-122 Sound pressure level 2) db(a) 76 76 76 76 75 75 Weight kg 4.4 4.4 4.4 4.4 7.7 7.7 lbs 9.7 9.7 9.7 9.7 17.0 17.0 1) 1% per minute peak, 10% per minute during start up. 2) Measurements according to EN ISO 3744: 2010 / db(a) [L PA, 1m ] values are calculated. Measured at max pressure and rpm for a motor pump unit. 4 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

4.2 PAHT 20-32 Pump size 20 25 32 Code number PAHT 180B0019 180B0020 180B0021 Code number PAHT G 180B1009 180B1010 180B1011 Code number ATEX PAHT G 180B6119 180B6120 180B6121 Housing material AISI 316 or higher Geometric displacement Pressure Min. outlet pressure Max. outlet pressure AISI 316 or higher AISI 316 or higher cm³/rev 20 25 32 in³/rev 1.22 1.53 1.95 barg 30 30 30 psig 435 435 435 barg 100 160 160 psig 1450 2321 2321 Inlet pressure, barg 0-6 0-6 0-6 continuous 1) psig 0-87 0-87 0-87 Max. inlet barg 20 20 20 pressure, peak 2) psig 290 290 290 Speed Min. speed rpm 700 700 700 Min. speed, continuous rpm 1000 1000 1000 Max. speed rpm 2400 2400 2400 Typical flow - Flow curves available in section 5 1000 rpm at l/min 16.9 20.6 28.0 max pressure 1500 rpm at max pressure 1200 rpm at 1800 rpm at Typical motor size 1500 rpm at 1800 rpm at Torque at max. outlet pressure Media temperature Ambient temperature Sound pressure level 3) l/min 27.0 33.2 44.2 gpm 5.4 6.7 9.0 gpm 8.6 10.6 14.0 kw 50Hz hp 60Hz 5.5 11.0 15.0 7.5 20.0 20.0 Nm 21.0 69.2 89.0 lbf-ft 15.5 51.1 65.7 C 2-50 2-50 2-50 F 37-122 37-122 37-122 C 0-50 0-50 0-50 F 32-122 32-122 32-122 db(a) 79 79 79 Weight kg 19 19 19 lbs 42 42 42 1) Above 1800 rpm inlet pressure 2-6 barg 2) 1% per minute peak, 10% per minute during start up. 3) Measurements according to EN ISO 3744: 2010 / db(a) [L PA, 1m ] values are calculated. Measured at max pressure and rpm for a motor pump unit. 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 5

4.3 PAHT 50-90 Pump size 50 63 70 80 90 Code number PAHT 180B0085 180B0086 180B0087 180B0088 180B0089 Code number PAHT G 180B1012 180B1013 180B1014 180B1015 180B1016 Code number ATEX PAHT G 180B6185 180B6186 180B6187 180B6188 180B6189 Housing material AISI 316 or higher Geometric displacement Pressure Min. outlet pressure Max. outlet pressure Inlet pressure, continuous Max. inlet 1) pressure, peak AISI 316 or higher AISI 316 or higher AISI 316 or higher AISI 316 or higher cm³/rev 50 63 70 80 90 in³/rev 3.05 3.84 4.27 4.88 5.49 barg 30 30 30 30 30 psig 435 435 435 435 435 barg 80 160 160 160 160 psig 1160 2321 2321 2321 2321 barg 0-6 0-6 0-6 0-6 0-6 psig 0-87 0-87 0-87 0-87 0-87 barg 20 20 20 20 20 psig 290 290 290 290 290 Speed Min. speed rpm 700 700 700 700 700 Min. speed, rpm continuous 1000 1000 1000 1000 1000 Max. speed rpm 1800 1800 1800 1800 1800 Typical flow - Flow curves available in section 5 1000 rpm at l/min 43.7 50.5 57.7 68.3 77.6 1500 rpm at 1200 rpm at 1800 rpm at Typical motor size 1500 rpm at 1800 rpm at Torque at max. outlet pressure Media temperature Ambient temperature l/min 68.7 82.1 92.9 108.5 122.6 gpm 14.0 16.4 18.7 21.9 24.9 gpm 21.8 26.3 29.6 34.5 38.9 kw 50 Hz hp 60 Hz 11 30 30 37 45 20 50 50 60 75 Nm 68.5 172.6 191.8 219.8 246.6 lbf-ft 50.6 127.4 141.5 162.2 182.0 C 2-50 2-50 2-50 2-50 2-50 F 37-122 37-122 37-122 37-122 37-122 C 0-50 0-50 0-50 0-50 0-50 F 32-122 32-122 32-122 32-122 32-122 Sound pressure level 2) db(a) 80 80 80 80 81 Weight kg 34 34 34 34 34 lbs 75 75 75 75 75 1) 1% per minute peak, 10% per minute during start up. 2) Measurements according to EN ISO 3744: 2010 / db(a) [L PA, 1m ] values are calculated. Measured at max pressure and rpm for a motor pump unit. 6 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

4.4 PAHT 256-308 Pump size 256 308 Code number PAHT 180B1001 180B1002 Code number PAHT G 180B6090 180B6091 Code number ATEX PAHT G 180B6190 180B6191 Housing material AISI 316 or higher Geometric displacement Pressure Min. outlet pressure Max. outlet pressure Inlet pressure, continuous AISI 316 or higher cm³/rev 256 308 in³/rev 15.6 18.8 barg 30 30 psig 435 435 barg 120 120 psig 1740 1740 barg 2-6 2-6 psig 29-87 29-87 Max inlet barg 15 15 pressure, peak 1) psig 218 218 Speed Min. speed rpm 450 450 Min. speed, continuous rpm 700 700 Max. speed rpm 1250 1250 Typical flow - Flow curves available in section 5 450 rpm at l/min 89.6 107.8 1250 rpm at 450 rpm at 1250 rpm at Typical motor size 1000 rpm at 1200 rpm at Torque at max. outlet pressure Media temperature Ambient temperature l/min 294.4 354.2 gpm 23.3 28.0 gpm 76.5 92.1 kw 50 Hz hp 60 Hz 55 75 100 125 Nm 549.6 661.3 lbf-ft 405.6 448.0 C 2-50 2-50 F 37-122 37-122 C 0-50 0-50 F 32-122 32-122 Sound pressure level 2) db(a) 82 87 Weight kg 105 105 lbs 231 231 1) 1% per minute peak, 10% per minute during start up. 2) Measurements according to EN ISO 3744: 2010 / db(a) [L PA, 1m ] values are calculated. Measured at max pressure and rpm for a motor pump unit. 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 7

5. Flow The flow (Q eff ) at various pressure (p max ) can be calculated with the following equation: At zero pressure the true flow equals the theoretical flow Q (th). Q eff = Q (th) [(Q (th) Q (p max )) x (p / p max )] The theoretical flow can be calculated with the following equation: Q (th) = V x n 1000 Q (th) : Theoretical flow (l/min / gpm) Q (p max ): Flows at (l/min and gpm), see 4.1-4.4 p max : Max pressure (barg / psig) p: Pressure (barg / psig) V: Displacement (cm 3 / rev.) n: Motor speed (rpm) 5.1 PAHT 2-6.3 typical flow curves at max pressure l/min 20 18 PAHT 6.3 16 14 12 10 8 6 4 PAHT 4.0 PAHT 3.2 PAHT 2.0 2 0 rpm 1000 1250 1500 1750 2000 2250 2500 2750 3000 gpm 5.0 4.5 PAHT 6.3 4.0 3.5 3.0 2.5 2.0 1.5 1.0 PAHT 4.0 PAHT 3.2 PAHT 2.0 0.5 0 rpm 1000 1250 1500 1750 2000 2250 2500 2750 3000 8 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

5.2 PAHT 10-12.5 typical flow curves at max pressure l/min 30 PAHT 12.5 25 20 PAHT 10.0 15 10 5 rpm 1000 1200 1400 1650 1800 2000 2200 2400 gpm 8 7 PAHT 12.5 6 PAHT 10.0 5 4 3 2 1 0 1000 1200 1400 1650 1800 2000 2200 2400 rpm 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 9

5.3 PAHT 20-32 typical flow curves at max pressure l/min 80 70 60 50 40 PAHT 32 PAHT 25 PAHT 20 30 20 10 0 rpm 700 950 1200 1450 1700 1950 2200 2400 gpm 25 20 PAHT 32 15 10 PAHT 25 PAHT 20 5 0 rpm 700 950 1200 1450 1700 1950 2200 2400 10 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

5.4 PAHT 50-90 typical flow curves at max pressure l/min 160 140 120 100 80 PAHT 90 PAHT 80 PAHT 70 PAHT 63 PAHT 50 60 40 20 0 700 950 1200 1450 1700 1800 rpm gpm 45 40 PAHT 90 35 PAHT 80 30 PAHT 70 25 PAHT 63 20 PAHT 50 15 10 5 0 700 950 1200 1450 1700 1800 rpm 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 11

5.5 PAHT 256-308 typical flow curves at max pressure l/min 400 350 300 PAHT 308 PAHT 256 250 200 150 100 50 0 rpm 450 550 650 750 850 950 1050 1150 1250 gpm 100 90 PAHT 308 80 PAHT 256 70 60 50 40 30 20 10 0 rpm 450 550 650 750 850 950 1050 1150 1250 12 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

6. Motor requirements The required motor power can be calculated by using the following equation: P = n x V x p 600.000 x η P: Power (kw) M: Torque (Nm) η: Mechanical efficiency p: Pressure (barg) n: Motor speed (rpm) V: Displacement (cm 3 /rev.) From the flow curves in item 5, you can determine the rpm of the pump at the desired flow. The required torque is calculated as follows: M = V x p 62.8 x η To determine the correct motor size, both the power and torque requirement must be verified. The mechanical efficiency of the pump, at max pressure, is as follows: PAHT 2, 3.2, 4, 6.3 0.8 PAHT 10, 12.5 0.9 PAHT 20, 25, 32, 50, 63, 70, 80, 90 0.95 PAHT 256, 308 0.95 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 13

7. Installation See the figure below for instructions on how to mount the pump and connect it to an electric motor or combustion engine. A B C D A: Pump B: Bell housing C: Coupling D: Motor If alternative mounting is required, please contact your Danfoss sales representative for further information. Note: Do not add any axial or radial loads to the pump shaft. For more information on the importance of proper filtration, including explanation of filtration principles, definitions, and guidance on how to select the right filter for your pump, please consult our Filtration information and specifications (Danfoss document number 521B1009). 7.1 Filtration Proper filtration is crucial for the performance, maintenance and warranty of your pump. Protect your pump, and the application in which it is installed, by always ensuring that filtration specifications are met, and by always changing filter cartridges according to schedule. Since water has very low viscosity, Danfoss PAHT pumps have been designed with very narrow clearances in order to control internal leakage rates and improve component performance. To minimize wear on the pump, it is therefore essential to filter inlet water properly. The main filter must have a filtration efficiency of 99.98% at 10 μm. We strongly recommend that you always use precision depth filter cartridges rated 10 μm abs. β 10 5,000. Please note that we do not recommend bag filters or string-wound filter cartridges, which typically have only 50% filtration efficiency. This means that out of 100,000 particles that enter such filters, 50,000 particles pass right through them; compare this to precision depth filters that are 99.98% efficient, and only allow 20 of the same 100,000 particles to pass through. 7.2 Noise Since the pump unit is mounted on a frame, the overall noise level can only be determined for a complete system. To minimize vibrations and noise throughout the system, it is therefore very important to mount the pump unit correctly on a frame with dampers and to use flexible hoses rather than metal pipes where possible. The noise level is influenced by: Pump speed: High rpm makes more fluid/structureborne pulsations/vibrations than low rpm. Discharge pressure: High pressures make more noise than low pressures. Pump mounting: Rigid mounting makes more noise than flexible mounting because of the structureborne vibrations. Be sure to use dampers when mounting. Connections to pump: Pipes connected directly to the pump make more noise than flexible hoses because of structure-borne vibrations. Variable frequency drives (VFDs): Motors regulated by VFDs can produce more noise if the VFD does not have the right settings. 14 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

7.3 Open-system design A B C D Inlet line: Dimension the inlet line to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, fittings with small pressure losses and restrictions). Inlet filter: Install the inlet filter (1) in front of the PAHT pump (2). Please consult the Danfoss filter data sheet for guidance on how to select the right filter. Monitoring pressure switch: Install the monitoring pressure switch (3) between the filter and the pump inlet. Set the minimum inlet pressure according to specifications described in item 4, technical data. The monitoring pressure switch stops the pump if inlet pressure is lower than the set minimum pressure. Monitoring temperature switch: Install the monitoring temperature switch (4) between the filter and the pump, on either side of the monitoring pressure switch. Set the temperature value according to technical data, item 4. The monitoring temperature switch stops the pump if inlet temperature is higher than the set value. E F Hoses: Always use flexible hoses (5) to minimize vibrations and noise. Inlet pressure: In order to eliminate the risk of cavitation and other pump damage, pump inlet pressure must be maintained according to specifications described in item 4, technical data. G Non-return valve (6): Should be installed after the outlet to prevent pump backspin, which may ruin the pump. H Pressure relief valve: As the Danfoss PAHT pump begins to create pressure and flow immediately after start-up regardless of any counter pressure, a pressure relief valve (7) should be installed to prevent system damage. Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between the non-return valve and the pump to protect against high-pressure peaks. 1 4 PI M 2 PI System 3 5 5 6 7 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 15

7.4 Closed-system design (not applicable for PAHT/PAHT G 256-308) A B C D Inlet line: Dimension the inlet line to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, fittings with small pressure losses and restrictions). Inlet filter: Install the filter (1) in front of the tank (2). Please consult the Danfoss filter data sheet for guidance on how to select the right filter. Monitoring pressure switch: Install the monitoring pressure switch (3) in front of the filter (1). Set the maximum inlet pressure to 2 barg (29.0 psig). The monitoring pressure switch will stop the pump (5) if inlet pressure is higher than 2 barg (29.0 psig), indicating that the filter element must be changed. Monitoring temperature switch: Install the monitoring temperature switch (4) in the tank. Set the temperature value according to technical data, item 4. The monitoring temperature stops the pump if inlet temperature is higher than the set value. E F Hoses: Always use flexible hoses (6) to minimize vibrations and noise. Inlet pressure: In order to eliminate the risk of cavitation and other pump damage, pump inlet pressure must be maintained according to specifications described in item 4, technical data. G Non-return valve (7): Should be installed after the outlet to prevent pump backspin, which may ruin the pump. H I J Pressure relief valve: As the Danfoss PAHT pump begins to create pressure and flow immediately after start-up regardless of any counter pressure, a pressure relief valve (8) should be installed to prevent system damage. System water filling: To ensure proper filtration of new water (10) supplied to the system, always use the filling valve (9). Minimum level switch: Install the minimum level switch (11) above the outlet of the reservoir. The level switch must stop the pump if the water in the reservoir is below the switch, which indicates that the reservoir is empty. 2 11 4 Reservoir PI M 5 6 6 7 PI System 1 3 9 10 8 16 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

8. Dimensions and connections 8.1 PAHT 2-6.3 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 17

8.2 PAHT 10-12.5 18 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

8.3 PAHT 20 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 19

8.4 PAHT 25-32 20 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

8.5 PAHT 50-90 521B1247 / DKCFN.PD.012.M2.02 / 11.2013 21

8.6 PAHT 256-308 22 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

9. Service Danfoss PAHT pumps are designed for long periods of service-free operation to ensure low maintenance and life cycle costs. Provided that the pump is installed and operated according to Danfoss specifications, Danfoss PAHT pumps typically run 8,000 hours between service. However, the service schedule for your Danfoss PAHT pump may vary according to the application and other factors. The life of a pump may be greatly shortened if Danfoss recommendations concerning system design and operation are not followed. In our experience, poor filtration is the number one cause of pump damage. Other factors that affect pump performance and lifetime include: running the pump at speeds outside specifications supplying the pump with water at temperatures higher than recommended running the pump at inlet pressures outside specifications running the pump at outlet pressures outside the specifications. We recommend that you inspect your pump after 8,000 hours of operation even if it is running without any noticeable problems. Replace any worn parts if necessary, including pistons and shaft seals, to keep your pump running efficiently and to prevent breakdown. If worn parts are not replaced, then our guidelines recommend more frequent inspection. Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 24 521B1247 / DKCFN.PD.012.M2.02 / 11.2013

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 24 521B1247 / DKCFN.PD.012.M2.02 / 11.2013