Fused Coordination Panelboard

Similar documents
Fused Coordination Panelboard

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Medium Voltage Controllable Fuse

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Now - Up To 400A Mains!

Specification made simple for selective coordination in a compact size

Operation and Maintenance manual. fusible shunt trip switch

Quik-Spec Coordination Panelboard Specifications

Power Transfer for Rail Vehicles SOLUTIONS GUIDE

TRANSPORTATION. Safety & Reliability for Electrical Power Railway Market

Selection and application guide

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

SOLAR POWER. Electrical Protection Solutions

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Bussmann series Quik-Spec Coordination Panelboard

SECTION PANELBOARDS

PSC Protection Semiconductor Square Body Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE

Quik-Spec Coordination Panelboard

Assembly not available for new installations.

Quik-Spec Electrical Gear

Power Electronics. Serving the Power Electronics Market. Safety & Reliability

Quik-Spec. Section Contents

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

WARREN COUNTY, N.Y. M/E REFERENCE

Pow-R-Line 3E Panelboard

MERSEN. Safety & Reliability for Electrical Power

A. Submit manufacturer's literature and technical data before starting work.

Selective Coordination Requirements

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Quik-Spec Coordination Panelboard A fusible panelboards

Service Entrance Methods

UL248 North American Low Voltage Fuses

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Compact Circuit Protector (CCP)

ASCO Low Voltage Automatic Transfer Switch Systems

Quik-Spec Coordination Panelboard A fusible panelboards

i n t e l l i g e n t F u s e t e C h n o lo gy M E d I U M Vo ltag E Co n T r o l l a B l E F U S E

Compact Circuit Protector (CCP)

Selective Coordination Enforcement:

ACHIEVING MAXIMUM BENEFITS WITH A FUSE PROTECTED MOTOR CONTROL CENTER

Low Voltage Fuses For Motor Protection

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

Evaluating Selective Coordination Between

ECET Distribution System Protection. Overcurrent Protection

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

QMB Fusible Panelboards

Electrical Safety and Overcurrent Protection

Low Voltage Automatic Transfer Switch Systems

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

Learning Module 10: Loadcenters. 101 Basic Series

General Purpose US Fuses

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Effective December 2015 Supersedes September 2013

SECTION MOTOR CONTROL

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Reducing. with Current. arc flash note 2. points of interest. Why Use Current Limiting Fuses. By mike lang, Principal field engineer

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

ACW Molded-Case Circuit Breaker UL 489 Listed

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

OTEC Transfer switch open transition

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Slim is in. Hospital Grade SmartlockPro Slim GFCI Receptacles. Specification and Ordering Guide

Quik-Spec Coordination Panelboard

Quick Start Guide TS 910 & TS 920

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Padmount Solid Dielectric Switchgear Catalog

Design Standards NEMA

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Optimizing Emergency Power Systems for Health Care Applications

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Solar Combiner Solutions

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

CUBEFuse. CUBEFuse catalog numbers (amps)

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

SECTION DISTRIBUTION AND GROUNDING

Transfer switch OTEC and OTECSE open transition

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Global line of premium compact low voltage switchgear. UL Low Voltage Disconnect Switches

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

XT IEC Power Control Manual Motor Protectors

Selection Guide Motor Control Device Solutions

PRE-ENGINEERED SOLUTIONS. LCP Series Fused Coordination Panel LPS Series Shunt Trip Disconnect Switch

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

Selecting Protective Devices

Electrical safety and reliability: Selective coordination. Protect with selective coordination

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

AutoLink Frequently Asked Questions

Transcription:

Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection

Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined in the National Electrical Code (NEC). Mersen s Fused Coordination Panelboard (MFCP) can simplify the process in achieving code compliance for designers. These panels are provided with a default short circuit current rating (SCCR) of 200kA and provide overcurrent protection through a combination of a circuit breaker and a fuse. The circuit breaker is designed to operate on overloads up to 2 times their rating and the fuse over 2 times up to 200kA. Feature UL 67 Listed panelboard with a default short-circuit current rating of 200kA Combination rated circuit breaker and fuse for branch circuit protection Class CC and Class J fuses for Branch short-circuit protection Maximum of 3 fuse sizes Selective Coordination between upstream and branch fuses when ratios are maintained FingerSafe fuseholders Interlocked branch circuit fuseholder and circuit breaker Standard 20 inch wide panel Surface & flush mount 20, 32, 42 branch circuits NEMA 1, 12 and 3R Feed-Through lugs Surge Protection MLO, Main Switch (with or without fuses) Service entrance rated Visible blades on main disconnect without removing covers Cover interlocked with main disconnect UL listed up to 600VAC Main lug only, non-fused main disconnect or fused main disconnect up to 400A Optional open fuse indication Optional integral surge protection Benefit Easily comply with NEC 110.10 as most systems will be below 200kA Fuses will open only on short-circuits Circuit Breaker can easily be reset on common overloads Standard fuse classes that are commonly stocked by distributors Typically already in inventory Simple selective coordination without short-circuit current study Meets requirements of NEC No exposed live components for increased safety Ensures that the fuse is disconnected on both line/load before removal Meets existing space requirements of other commercial available panelboards Increased flexible options to meet specific application requirements Visual verification of disconnect operation Ensures that power is disconnected before cover can be removed Meets most common North American voltages Provides designers with options Easy identification of open branch fuses Easily provide surge protection for critical branch circuits

Branch Circuit Protection Overloads are the most common over current condition and MFCP s innovative combination branch circuit protection provides resettable overload protection up to 2 times the circuit rating while still providing true class CC and J protection for your critical loads on high current faults. The kits below provide everything needed for expansion of an existing panel. Circuit Breaker provides resettable overload protection for low level faults. Includes ratings from 15A to 100A in 1,2 or 3 pole options Mechanically Interlocked to ensure the fuseholder is not opened while power is on Only 3 fuse ratings are required to provide short-circuit protection. Insulated Bus bar makes the connection between the circuit breaker and fuseholder Part number Poles Current rating Fuse (included) MFCP-K-15-1 1 MFCP-K-15-2 2 15A MFCP-K-15-3 3 MFCP-K-20-1 1 MFCP-K-20-2 2 20A MFCP-K-20-3 3 ATDR30 MFCP-K-25-1 1 MFCP-K-25-2 2 25A MFCP-K-25-3 3 MFCP-K-30-1 1 MFCP-K-30-2 2 30A MFCP-K-30-3 3 Part number Poles Current rating Fuse (included) MFCP-K-35-1 1 MFCP-K-35-2 2 35A MFCP-K-35-3 3 MFCP-K-40-1 1 MFCP-K-40-2 2 40A MFCP-K-40-3 3 AJT60 MFCP-K-50-1 1 MFCP-K-50-2 2 50A MFCP-K-50-3 3 MFCP-K-60-1 1 MFCP-K-60-2 2 60A MFCP-K-60-3 3 Please contact the factory for 100A branch circuits.

Branch Circuit Kit Highlights Easy selectivity ratios with upstream fuses Voltage: 120/208, 120/240, 277/480, 347/600 Main Bus: 250A or 400A, MLO, Fused Main or Non-fuse Main disconnect SCCR: 200kA Surge Protection (SPD) optional 20, 32 or 42 branch circuits Standard 20" wide Feed through lugs optional Surface mount Uses commonly available class CC & J fuses Dimensions (NEMA 1 Enclosures) For standard panels: Width = 20 inches Depth = 6 inches Height varies depending on number of circuits and main options (see table below). Number of Circuits Height (inches) 250A-Bus 400A-Bus 20-circuit 44 56 32-circuit 62 74 42-circuit 86 86 Main Up to 400A Fused Main Disconnect Allows for panel isolation Lockout provision Visible contacts Interlocked with cover NEMA 1 Enclosure Specifications Tub: Galvanized unpainted steel. One endwall is provided with knockouts, and the other endwall is blank. Door: Equipped directory card, flush mount lock Trim and Door Finish: ANSI 49 grey baked enamel electrodeposited over cleaned, phosphatized steel AJT Amp-Trap 2000 fuses Main Fuse Time Delay 2:1 coordination ratio 600VAC interrupting rating 200kA Example Drawings: Branch Circuits Circuit breaker opens overloads up to 2 times circuit rating ATDR, AJT fuses open short circuit currents Fuseholder interlocked to prevent opening while energized. Circuits up through 100A 1, 2 & 3 pole. True Class J and CC protection.

selective coordination with Mersen s fcp Achieving selective coordination typically requires a costly short circuit current study. However with the Mersen Fused Coordination Panelboard, coordination can easily be determined with upstream Mersen fuses. MFCP utilizes Amp-Trap 2000 ATDR and AJT fuses for branch circuits. Simply maintain a 2:1 ratio with upstream Amp-Trap 2000 fuses and the system will coordinate. Many circuit breakers will coordinate easily with downstream fuses. A system that is selectively coordinated will ensure that any fault condition is localized to the nearest overcurrent protective device. This increases system reliability and decreases downtime. Selective coordination is desired for all systems but is also mandatory per NEC for critical circuits: 620.62 Elevator Circuits 700.27 Emergency Systems 701.18 Legally Required Standby Systems By localizing a fault to the nearest overcurrent device selective coordination prevents unnecessarily disconnecting other circuits in the system. An electrical system that utilizes Mersen fuses can simply be selectively coordinated by meeting the minimum amp rating ratios. By adhering to the minimum fuse ratios engineers and installers can save time and money because no complex coordination study is required. Surge Protection In 2014, NEC added article 700.8 which requires that a surge protective device must be installed in or on all new emergency system panelboards. NEC defines emergency systems as legally required systems intended to automatically supply illumination, power and systems essential for safety to human life. MFCP helps easily meet this requirement with the optional built-in Surge-Trap pluggable. Surge-Trap utilizes Mersen s patented fail-safe TPMOV technology. Ordering Details MFCP is a highly configurable panelboard with many options. Please contact Mersen Technical Services at 978-465-4853 or technicalservice.nby@mersen.com for submittal and bid packages.

Main production sites Industrial or commercial branch A WORLD LEADER in safety & reliability for electrical power. A GLOBAL PLAYER A global expert in materials clients specific needs to and solutions for extreme enable them to optimize environments as well as in their manufacturing process the safety and reliability in sectors such as energy, of electrical equipment, transportation, electronics, Mersen designs innovative chemical, pharmaceutical, solutions to address its and process industries. BR-FCP-001 02.15 2500 Printex. Mersen 2015 MERSEN U.S.A. 374 Merrimac Street Newburyport, MA 01950 U.S.A. T : 978 462 6662 F : 978 462 0181 MERSEN France 15 Rue Jacques de Vaucanson F-69720 Saint Bonnet de Mure France T : +33 (0)4 72 22 66 11 F : +33 (0)4 72 22 67 13 MERSEN Toronto 6200 Kestrel Road Mississauga, Ontario Canada L5T 1Z1 T : 416 252 9371 F : 416 252 6572 MERSEN Shanghai No.55-A6. Shu Shan Road Songjiang 201611 Shanghai Tel: +8621 67602388 ep.mersen.com