Installation and Operation Manual Nickel Iron MG300 Battery

Similar documents
Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

FLUSH EYES IMMEDIATELY WITH WATER. GET MEDICAL HELP FAST. SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS.

VRLA Batteries. Battery Installation And Start up Guide

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Nickel Cadmium Clear Case

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

Installation, Operation & Maintenance Manual

SMU-F Valve Regulated Lead Acid Battery

AGM Series. Installation Manual AGM Series Modular Battery Systems

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

MATERIAL SAFETY DATA SHEET MSDS009. Ultralife Batteries, Inc Technology Parkway Newark, NY

Light condition and operation Windshield glass condition Wiper blade condition Paint condition and corrosion Fluid leaks Door and hood lock condition

Installation & Maintenance Manual

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

SMU-F. AlphaCell TM. Technical Manual. Valve Regulated Lead Acid Battery. AlphaCell SMU-F Valve Regulated Lead Acid Battery Effective: February 2007

Proper Torque Values for Connection Hardware. 90 to 100 in-lbs

Regulated Hose Supply Installation, Operation & Maintenance Manual

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES

Material Safety Data Sheet

Nickel Cadmium Batteries BLOCK TYPE

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Matson Jump Starter Operator s Manual

USER GUIDE 12 V Lead acid batteries Ah

MATERIAL SAFETY DATA SHEET

AlphaCell SMU. Technical Manual. AlphaCell SMU. Effective: January Alpha Technologies

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OBE, OBEXU, ON BOARD Battery Chargers

EnergyCell FLA Series. Owner s Manual

AlphaCell OPzS. Technical Manual. Stationary Flooded Tubular Lead-acid Batteries. AlphaCell OPzS Battery. Effective: January Alpha Technologies

2 VOLT STATIONARY BATTERIES INSTALLATION

OBAE, OBAEXU, ON BOARD Battery Chargers

Single-Point Watering Kit User s Guide

PowerSafe OPzV Operation Guide for Solar Applications

PowerSafe OPzV Operation Guide for Solar Applications

Fiber Backhaul Enclosure

JUMP STARTER OPERATOR S MANUAL RA1900

HAZE 6/12 Volt. STATIONARY 6/12 Volt BATTERIES. HAZE Battery Co. INSTALLATION and OPERATING INSTRUCTIONS. Supplied Worldwide by :

Stationary Energy Storage Valve Regulated Lead-Acid Batteries. LL Series

Technical Specification

Installation And Operation Instructions

Sentry Battery Charger. Installation and Operations Manual Section 75

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Installation And Operation Instructions

18 KG MOBILE SODA BLASTING UNIT

Smart Charger 12-24V 60A, 1600W

Jumpbox Model SP-12V1500-JB1

EcoSafe EOPzV. Operation Guide for Solar Applications

Installation and Operating Instructions. Solar System Controller ISC3020

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

OPERATING MANUAL 18V Ni-Cd Battery Pack

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

60V RECHARGEABLE LITHIUM-ION BATTERY

Product Specification

Installation, Maintenance and Warranty Flat Plate Battery

PAC 600 PAC 800 PAC 800 comfort

Installation And Operation Instructions

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AG-HA-2500N GASOLINE GENERATOR

USER MANUAL. Model: minibatt POCKET VR

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

Sherman + Reilly Battery-powered Pistol Grip Cable Cutters

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

C&D Technologies, Inc. Dynasty Division 900 East Keefe Avenue Milwaukee, WI53212 Phone: Fax:

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Single Cell Range Technical manual

C3 Operating Instructions

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

STEP-BY-STEP INSTALLATION GUIDE

Instructions for use. Hawker Premier

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV.

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

FIAMM Industrial Batteries December 2012 FIAMM AGM Valve Regulated Recombination Batteries: FLX Series- Engineering Manual TABLE OF CONTENTS

MODEL ELC-12/40-CVM-D BATTERY CHARGER

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

- Optional Audio warning when discharge test is complete or tester malfunction.

Illuminator System Series CM

TECHNICAL MANUAL RS02061

QPET, QPETXU Battery Chargers

AUTOMATIC BATTERY CHARGER AUTOMATISCHES BATTERIELADEGERÄT CHARGEUR DE BATTERIE AUTOMATIQUE AUTOMATISCHE ACCULADER 12A RMS (8A DC) MCH12A

Specification Approval Sheet

SOLAR CHARGE CONTROLLER

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA)

NB Module. Installation and Operation Manual. California Proposition 65 Warning:

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Transcription:

Installation and Operation Manual Nickel Iron MG300 Battery Effective: July 2015

Nickel Iron MG300 Battery MG300 Encell Technology, Inc. Effective Date: July 2015 Encell Technology, Inc. NOTE: Photographs contained in this manual are for illustrative purposes only. These photographs may not match your installation. NOTE: Operator is cautioned to review the drawings and illustrations contained in this manual before proceeding. If there are questions regarding the safe operation of this product, please contact Encell Technology or your nearest Encell representative. NOTE: Encell shall not be held liable for any damage or injury involving its enclosures, power supplies, generators, batteries, or other hardware if used or operated in any manner or subject to any condition not consistent with its intended purpose, or is installed or operated in an unapproved manner, or improperly maintained. Contacting Encell Technology: For general product information and customer service (8 AM to 5 PM, Eastern Time), please call +1-386-462-2643 Or visit the Contact Us page on the Encell Technology website.

TABLE OF CONTENTS 1.0 GENERAL SAFETY NOTES... 1 1.1 Chemical Hazards... 1 1.2 Safe Handling... 1 1.3 Recycling and Disposal Instructions... 1 2.0 RECEIVING THE BATTERY... 2 2.1 Shipment Contents... 2 2.2 Shipment Inspection... 2 3.0 SYSTEM SITE PREPARATION... 4 3.1 Location... 4 3.2 Ventilation... 4 3.3 Cell Layout, Spacing and Constraints... 4 4.0 SYSTEM INSTALLATION... 6 5.0 CONDITIONING... 7 6.0 SYSTEM MAINTENANCE... 8 6.1 General Maintenance... 8 6.2 Cell Watering... 8 7.0 SYSTEM MONITORING... 9 8.0 RECOMMENDED APPLICATIONS... 10 8.1 Standard 80% Input Application Regime...10 8.2 Standard 50% Input Application Regime...10 9.0 SYSTEM EQUALIZATION... 11 10.0 STORAGE... 12 10.1 Filled Charged/Discharged Cells...12 10.2 Empty Discharged Cells...12 ATTACHMENT 1: Sample MG1, 360 Cell Accessory Pack List... 13 ATTACHMENT 2: Site-Specific Assembly Instructions... 14 ATTACHMENT 3: Battery Watering Instructions... 15

1.1 GENERAL SAFETY NOTES Review the drawings and illustrations contained in this manual before proceeding. If there are any questions regarding the safe installation or operation of the system, contact Encell Technology or the nearest Encell representative. Save this document for future reference. 1.2 Chemical Hazards Nickel Iron (NiFe) batteries contain dangerous voltages, currents and corrosive material. Battery installation, maintenance, service and replacement must be performed only by authorized personnel. The electrolyte in Nickel Iron batteries, consisting of a dilute caustic sodium hydroxide with a lithium hydroxide component, is harmful to the skin and eyes. 1.3 Safe Handling The servicing and connection of batteries shall be performed by, or under the direct supervision of, personnel knowledgeable of batteries and required safety precautions. Always wear protective clothing (insulated gloves, eye protection, etc.) when installing, maintaining, servicing, or replacing batteries. Wear shock and arc flash protection when required based on the system application. Remove all metallic objects from hands and neck. Prior to handling the batteries, touch a grounded metal object to dissipate any static charge that may have developed on your body. Never use uninsulated tools or other conductive materials when installing, maintaining, servicing, or replacing batteries. Use tools with insulated handles. Do not rest any tools on top of batteries. Use special caution when connecting or adjusting battery cabling. If an improperly connected or unconnected battery cable contacts an unintended surface, arcing, fire, or explosion can result. Adequate spacing between individual batteries is necessary for convection cooling. Encell-designed racking systems are configured to allow for proper cooling of the cells. Batteries produce explosive gases especially during overcharge conditions. Keep all open flames and sparks away from batteries. Do not charge batteries in a sealed container. All battery compartments must have adequate ventilation to prevent accumulation of potentially dangerous gas. Ventilation should prevent trapped hydrogen gas pockets from exceeding a 1% concentration as per regulation 70E of the National Fire Protection Agency (NFPA). If any battery emission contacts the skin, neutralize with vinegar immediately and then wash thoroughly with water. Follow your company s approved chemical exposure procedures. Neutralize any spilled battery emission with plenty of water. If necessary, use sand to soak up the spill before diluting with water. Report a chemical spill using your company s spill reporting structure and seek medical attention if necessary. Batteries should be replaced by authorized personnel using batteries of identical type and rating. Never install old, untested batteries. Replace immediately any batteries that show signs of cracking, leaking, or swelling. 1.4 Recycling and Disposal Instructions Spent or damaged batteries are considered environmentally unsafe. Always recycle used batteries or dispose of the batteries in accordance with all federal, state and local regulations. 1

2.1 RECEIVING THE BATTERY The cells are not to be stored in the packaging; therefore, unpack the battery immediately upon receipt. The shipping container will be labeled indicating the top of the shipping container. Do not overturn the package to avoid damage to the cells or leaking of electrolyte. 2.2 Shipment Contents The battery system will generally include battery system cells and an accessory pack. Figure 2-1 (on the following page) shows a typical battery system cell. The cells will be delivered filled with electrolyte and in a discharged state. The cells are shipped with a vented white shipping cap equipped with a flame arrestor. The cells are ready for installation, conditioning and then application. The accessory pack will generally include connector bars, tools and the watering system components. A sample accessory pack list is included as Attachment 1. 2.3 Shipment Inspection Visual inspection of the shipment contents should be completed immediately upon receipt. An inventory of the cells and accessory package contents should be completed upon receipt. The customer should take note of any visual indications of electrolyte spill or leakage. Any evidence of spilling or leaking during shipment should be reported to the purchasing agent. Note: The level of electrolyte in each cell may be different depending on storage time, temperature or other environmental factors. Varying electrolyte levels are not necessarily indications of leaks or spills. A leak or spill in electrolyte will appear either as a yellowish liquid or as dried electrolyte with crystal deposits. Important: Do not use any cells that show signs of electrolyte leakage. Do not use any cell if the center watering cap is missing. Do not use any cells that show deposits of material on the terminals. Warning: Under no circumstances should the electrolyte level in the cells be topped up until after the cells have completed the first conditioning charge cycle. Topping up (adding deionized water or electrolyte) in the discharged state may cause an overspill during the first charge. Watering should occur during the rest after charge of the first conditioning cycle (see Section 5.0). Detailed watering instructions are included in Section 6.2 and in Attachment 3. 2

Figure 2-1: MG1 Cell Showing Minimum and Maximum Fill Lines Maximum Fill Line Electrolyte Level Minimum Fill Line 3

3.1 SYSTEM SITE PREPARATION This section includes general discussions of site location, ventilation, and system layout. 3.2 Location Install the battery in a dry, clean and secure room. Avoid direct sunlight and heat. The battery will give optimal performance and maximum service life if the ambient temperature lies between 10 C and 30 C. Encell recommends installing an atmospheric monitoring system to monitor site conditions. It is recommended the monitoring system be equipped with alarms for temperatures outside of optimal temperature ranges. The site floor should be level and rated to uphold the weight of the battery system. With larger systems, adequate spacing between rows should be provided to allow access for routine maintenance. 3.3 Ventilation During the latter part of charging, battery gases (a mixture of oxygen and hydrogen) are emitted. At normal application charging rates, the gas evolution is very small, but some ventilation is necessary. During overcharge, gassing evolution increases. Site ventilation should be equipped to prevent trapped hydrogen gas pockets from exceeding a 1% concentration as per US Regulation 70E of the National Fire Protection Agency (NFPA). Encell recommends installing an atmospheric monitoring system equipped with an alarm for hydrogen concentrations above these thresholds. The customer is responsible for meeting applicable local, state and federal regulations. 3.4 Cell Layout, Spacing and Constraints The cell layout will be site specific according to each customer application or system size. However, in general, the cells should be configured in the following manner for longevity and peak performance: The MG300 cells should be placed in rows with the small sides of the cell abutted against one another. The cells should be abutted end to end and secured against one another to avoid overturn. Spacing between rows of the cells should be a minimum of 0.5 inches. (See Figure 3-1 for a layout example.) Please ensure adequate spacing between modules, rows, and/or shelves is provided for long term cell maintenance; e.g., watering and voltage monitoring. For peak long term performance, cell constraints are recommended but not mandatory. Constraint of the cells will extend cycle life of the battery system. If the racking system does not provide constraints, a simple solid fixture (4 inches wide by 8.5 inches tall) installed at the end of each row can be held in place with ratchet straps. A fixture that is heat conductive (such as a steel plate) is recommended. 4

Figure 3-1: Cell Layout Example Short Links Long Link BACK 4 Tube FRONT 7 Tubes 5.5 Tube 5

4.1 SYSTEM INSTALLATION This section will provide general information on building the battery system. The general order of activities is listed as follows. Design the battery layout according to system application. After carefully removing the cells from the shipping container, assemble the cells according to the system layout. Confirm cell polarity is in appropriate orientation. Cells should be configured so that they are abutted end to end (narrow sides together). Apply contact NO-OX-ID grease to terminal threads and top contact surface. Connect the individual cells using the short connector links, flat washer, split lock washer, and M8 screw. o If the system includes more than one string, string-to-string connections with the long links will be made at the end of set up. o Applicable company, local, state and federal safety regulations must be followed. Install the short link covers. Remove the white shipping caps. Install the watering valves in each cell. Use the red water valve wrench to tighten each valve in place. Attaching tubing provided in the accessory pack. If you do not have precut tubing, use tubing cutters to cut tubing to length for fitting between the cells. If you have precut tubing, fit the cell to cell connection tubing into the ports on the vent valves between the cells. Plug all remaining ports with the red caps. Attach the filling port to the end cell for deionized water filling. If the system will include voltage monitoring (recommended), install the voltage monitoring leads and set up voltage monitoring system. Make final row to row connections using long link connectors and link covers. Torque all of the connections to 160 to 200 in-lbs. Install the watering system manifold to the individual modules (if applicable). Confirm that connector bars and all connection wires meet the rating for the maximum current to be employed in the system application. Connect battery system to the power supply. Important: Under no circumstances should the cells be topped up before the cells are in over-charge (gassing at the end of charge) during the first conditioning cycle (Section 5.0). Topping up (adding) deionized water or electrolyte in this discharged state may cause an overspill during the first charge. See watering instructions in Section 6.0 for more detailed information. Each site application will be different. Always comply with the site- or projectspecific assembly drawings, circuit diagrams and other separate instructions. 6

5.1 CONDITIONING After completing system set up, the cells should undergo a series of conditioning cycles prior to beginning application. Conditioning is necessary because of the manner in which the cells were prepared specially for shipment. Conditioning reinitiates the cells for optimum performance. Conditioning regimes are customer-, site-, and application-specific. Please contact your Encell purchasing agent or on-site Encell representative to develop the appropriate conditioning regime for your system. A typical recommended conditioning regime for Encell NiFe batteries is as follows: Where C is the capacity in Ampere-hours (Ah) of the system, Charge at C/2 for 3 hours Rest 2 hours Discharge at C/10 to 1.1V average per cell Rest 2 hours Repeat for a total of 3-5 cycles. For example, if you have a 40 cell, 300Ah system Charge at 150A (300/2) for 3 hours Rest 2 hours Discharge at 30A (300/10) down to a battery voltage of 44V (1.1V * 40). Rest 2 hours If the system components cannot complete the charge/discharge rates as recommended above, please contact the purchasing agent for alternative conditioning regimes per the customer system capabilities. 7

6.1 SYSTEM MAINTENANCE This section discusses system maintenance activities including general maintenance and cell watering. 6.2 General Maintenance General maintenance of the system should be performed in a discharged state. Cells in a charged state have the potential for igniting resident hydrogen gases if a spark occurs. Always keep the battery, its container and installation equipment clean and dry. Check the nuts on the battery terminals at least every six months to ensure they are seated firmly. Clean watering valves annually. Replace defective watering valves. At regular intervals, smear all bright metal parts on the cells, such as battery terminals and cell connectors, with diluted, acid-free petroleum jelly. This does not include the cell cases. Take care that the diluted petroleum jelly is not applied to plastic parts of the battery. Do not use solvent based cleaning agents. Do not use or store NiFe batteries in the same room as lead acid batteries. Take suitable precautions, such as ventilation or hermetic isolation of the rooms, to keep the charging gases from lead acid batteries away from NiFe batteries. Do not use tools for lead acid batteries with NiFe batteries. 6.3 Cell Watering Cell maintenance will be required during system operation. Cells should be filled with deionized water only. Any other water (tap water, spring water, etc.) will damage the cell. During cycles with overcharge, water loss will increase, and watering may be needed every cycle (for example, during conditioning and equalization). Cell watering maintenance requirements during application will be dependent on site-specific application regimes. Detailed watering instructions are included as Attachment 3. 8

7.0 SYSTEM MONITORING Voltage monitoring of the battery system is recommended to evaluate and track cell performance in long term battery system applications. Individual cell monitoring is best. If individual monitoring is not an option, reduced monitoring of cells in groups of up to 20 cells is acceptable. A monitoring system with remote access is highly recommended. This type of system would allow the manufacturer access to data to assist with system evaluation. 9

8.1 RECOMMENDED APPLICATIONS System applications will be site- and application-specific. As examples, two standard application regimes for Encell NiFe batteries are included here. 8.2 Standard 80% Input Application Regime Where C is the capacity in Ampere-hours (Ah) of the system, Charge at C/4 for 3.4 hours Rest 4 hours Discharge at C/4 to 1.1V average per cell Rest 4 hours Repeat Equalization cycle to be performed once per quarter (see Section 9.0) For example, if you have a 40 cell, 300Ah system Charge at 75A (300/4) for 3.4 hours Rest 4 hours Discharge at 75A (300/4) down to a battery voltage of 44V (1.1V * 40). Rest 4 hours 8.3 Standard 50% Input Application Regime This application may be used during certain times of the year when the charging rates may be limited. Where C is the capacity in Ampere-hours (Ah) of the system, Charge at C/4 to 15% SOC (100 minutes is fully discharge) Charge at C/4 for 2 hours Rest 4 hours Discharge at C/4 for 2 hours or 1.1V average epv (whichever is sooner) Rest 4 hours Repeat Equalization cycle to be performed monthly (see Section 9.0) These are just two application regimes that may be employed. Please discuss your site specific needs with your Encell purchasing agent to develop the site application regime applicable to your site. 10

9.1 SYSTEM EQUALIZATION During application, the cells should periodically undergo a series of equalization cycles. Equalization is necessary for optimum long term performance. The optimal equalization regime recommended is as follows: Where C is the capacity in Ampere-hours (Ah) of the system, Charge at C/2 for 3 hours Rest 2 hours Discharge at C/10 to 1.1V average per cell Rest 2 hours Complete 3 to 5 cycles. If the system components cannot complete the charge/discharge rates as recommended above, please contact the purchasing agent for alternative equalization regime per the customer system capabilities. 11

10.1 STORAGE Rooms where batteries are stored must be clean, dry, cool and well ventilated. The ambient temperature should be 50 F (10 C) to 86 F (30 C). Do not store cells in the packaging or expose to direct sunlight or UV-radiation. 10.2 Filled Charged/Discharged Cells Filled cells can be stored no longer than 12 months from the time of delivery. Filled cells stored at temperatures above 86ºF (30 C) will lose capacity. If electrolyte has been lost during transport, refill the cell to the MIN mark with electrolyte before attempting to store it. 10.3 Empty Discharged Cells To store cells and batteries for long periods of time without damage, make sure they are deeply discharged, drained, well-sealed, and kept in appropriate storage facilities. For long term storage of empty cells, please contact your purchasing agent for more detailed instructions. 12

ATTACHMENT 1: Sample MG1, 360 Cell Accessory Pack List Part Drawing (not to scale) Part Part Description Quantity Purpose Number 150001 Valve, Watering, 2.5"lg, 360 Cell watering 1.8"Shut ht, Flame Arrestor, Red 152001 Cap, Manifold, Red, EPDM 95 Seal open Tee ports on Watering Valve (5-Extra) 153003 Tubing,.25"ID,.44"OD, EDPM, 45 Cell to cell watering connection Black (102mm/4.0") 153012 Tubing,.25"ID,.44"OD, EDPM, 45 Cell to cell watering connection Black (140mm/5.5") 153013 Tubing,.25"ID,.44"OD, EDPM, Black (178mm/7.0") 270 Cell to cell watering connection 180002 Manifold, Watering, 40 MG1 Cells 9 Quick connection and manifold for watering battery to battery 151002 Water Valve Wrench 1 Installing or removing Watering Valve 140008 Link, Connection,.875"x 270 Cell to cell connection (short) 4.32"x.13"thk, M8 hole, Ni- Plated Cu 140009 Link, Connection,.875"x 5.88"x.13"thk, M8 hole, Ni- Plated Cu 63 Battery to battery connection (long) 141002 Link, Cover,.75"x 4.6"x.075"thk, PP, Black 270 Covers cell to cell connection (short) 141003 Link, Cover,.75"x 6.2"x.075"thk, PP, Black 63 Covers cell to cell connection (long) 141005 Link, Cover, Cable.75"x 2.0"x.075"thk, PP, Black 100027 Washer, Flat, M8, 8.4mm ID, 16mm OD, 1.4mm - 1.8 mm thk, 304 SS 100031 Washer, Split Lock, M8, 304 SS, DIN 127 100026 Screw, Socket Head Cap, M8 x 1.25 x 16, 304 SS 520003 Grease, Dielectric, NO-OX-ID A Special, # 10210-8 oz tin with brush 55 Covers cable connection (1-Extra) 725 Terminal connections (5-Extra) 725 Terminal connections (5-Extra) 725 Terminal connections (5-Extra) Recommended Torque: 160-200 in-lbs (6mm Hex Wrench) 1 Apply thin coating to cell and battery terminal connections for corrosion protection.

ATTACHMENT 2: Site-Specific Assembly Instructions When applicable, site-specific assembly and installation instructions will be included in this section. Each site application will be different. Always comply with the site- or projectspecific assembly drawings, circuit diagrams and other separate instructions.

ATTACHMENT 3: Battery Watering Instructions WARNING WEAR EYE PROTECTION AND PROTECTIVE CLOTHING WHEN WORKING WITH BATTERIES. ELECTROLYTE IS HIGHLY CORROSIVE. IF ELECTROLYTE SPLASHES INTO THE EYES OR ONTO THE SKIN, RINSE WITH PLENTY OF CLEAR WATER AND SEEK IMMEDIATE MEDICAL ADVICE. FOLLOW THE SAFETY DATA SHEET (SDS) FOR ADDITIONAL INFORMATION INCLUDING HAZARDS IDENTIFICATIONS, ELECTROLYTE FIRST AID MEASURES AND PRECAUTIONS FOR SAFE HANDLING AND USE. The following provides the recommended watering instructions for the cells. Cells should be filled with ONLY deionized (DI) water using the instructions below for best performance. Using other liquids will cause permanent damage to the cells. FAILURE TO FOLLOW THIS PROCEDURE WILL VOID THE MANUFACTURER S WARRANTY. GENERAL INFORMATION During shipment and storage, the electrolyte level within each cell may become variable. Upon receipt, the electrolyte level may appear to be below the minimum fill line (see Figure A3-1). Do NOT add deionized water to the cells in this discharged state, as this will cause the electrolyte overflow during the first charge cycle. Following system installation, the first cycle should be an initial charge and discharge of the battery system to condition the system. During the first cycle, the cells should be filled will deionized water during the rest immediately following the first charge cycle using the automatic watering system and following the directions below. Electrolyte levels of the cells should be monitored periodically. There are two fill lines identified on the labels on each cell showing minimum and maximum fill levels (Figure A3-1). The minimum fill line indicates the electrolyte level, at the end of discharge cycle, which would trigger a watering after the subsequent charge cycle. The maximum fill line indicates where the automatic stop valve will stop the flow of DI water when using the automatic watering system. Note: Only use automatic watering system after a charge cycle. Frequency of filling cells will be dependent on the charge current and amount of charge input of the battery application. Increased current and charge input will increase the frequency of filling cells. During conditioning/maintenance cycling, electrolyte levels will require more frequent monitoring/filling.

Figure A3-1: Cell Showing Minimum and Maximum Fill Lines Maximum Fill Line Electrolyte Level Minimum Fill Line DETAILED CELL WATERING INSTRUCTIONS 1. Electrolyte levels of all cells should be monitored for the need for filling at the end of a discharge cycle on a periodic basis. 2. If the electrolyte level at the end of a discharge cycle is below the minimum fill line on any cell in the battery system, the cells require watering. DO NOT WATER USING AUTOMATIC WATERING SYSTEM DURING DISCHARGE OR IN REST AFTER A DISCHARGE CYCLE. 3. IMPORTANT: Watering of the cells using the watering system with automatic stop valves should ONLY occur at the end of a charge cycle or during the rest immediately following a charge cycle. In high voltage systems, the rest after charge cycle is recommended. The end of a charge cycle represents the highest level the electrolyte will rise during a cycle. Thus, watering during this time using the automatic stop valve will protect against overflow of electrolyte during charge. Filling cells during any other time using the automatic stop valves may cause electrolyte overflow during charge.

4. The watering valves are equipped with an automatic stop valve which will stop the flow of DI water when the cells have reached the maximum fill line. 5. The water pump is equipped with a visual indicator for water flow. The indicator has three red balls that will move during flow and will stop when flow is ceased.

6. If visual monitoring during a discharge cycle triggers a watering event due to electrolyte levels being below the minimum fill line, use the automatic watering system during the rest after the subsequent charge cycle to fill all the cells in the system with DI water. a. Connect the water pump to a source of DI water. b. Connect the water pump to the ¼ Barb Male Coupler with Dust Protector that connects to the watering manifold system. c. Pump DI water through the system until the cells are full. d. Stop the flow of DI water when the visual indicators have stopped movement. Continuing flow will add unnecessary pressure to the system. GENERAL MAINTENANCE If electrolyte rises and leaks from the valve(s) during charge and not during a watering event, the cell(s) have been overfilled during a previous cycle. If the electrolyte level rises above the maximum fill line during watering and electrolyte exits through the valve vents, the watering valve requires maintenance. Use the valve wrench to remove the valve. Rinse the valve with DI water and test for restored functionality of the automatic stop valve. If functionality cannot be confirmed, replace the valve. If DI water leaks from the top of the valve from the port of the tube fitting tee while filling cells, the O-ring on the tube fitting tee (Part Number 154002) needs replacing. If a cell is not receiving water during a watering event, the valve may be closed shut and requires replacing. Use the valve wrench to remove the valve and replace the valve with a new valve.