MG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6

Similar documents
MGV25.X USER GUIDE. Ver. 3.1 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.X

MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5

BAH series Use and Maintenance Manual

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Montanari Giulio & C. s.r.l.

BELT CONVEYOR CB/M5 Series

Electrically Released Brakes ERS VAR10 SZ 5000/5000

USER INSTRUCTIONS FOR SLIDING DOORS

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Hollister-Whitney Elevator Corporation

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Position Limit Switches PLTA

BELT CONVEYOR PNL/4 Series User and maintenance manual

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

Automatic concealed bollards 275 H600 and 275 H800 with pit

Crane fork KGM/KGA and KGQ/KGL

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

BOX A3 TEST REL. DATE R.T. Check and Approval

Ex m Solenoid Operator Type 0519

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Solenoid Operator 0516 / 1216

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

Solenoid Operator 0513 / 1213

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

VALIADIS S.A. HELLENIC MOTORS

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

INSTRUCTION MANUAL MAGNA RAIL

DYNATECH PROGRESSIVE SAFETY GEAR PQ-3400-UD

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Type 6213 EV, 6281 EV

FLEXIBLE COUPLINGS RU-STEEL Annex Atex 95

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

VA-7450 Series. Electric Valve Actuators

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

PNEUMATIC PUMP Series

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

Safety Valve HM-SV Installation, maintenance and startup guide

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION AND USE MANUAL

Declaration of Conformity as per Directive 97/23/EC

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Installation Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MANUAL FOR USE AND MAINTENANCE OF THE MACHINE GALAXY

ADB.3... DIRECTIONAL CONTROL

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

Explosion and flame-proof cast iron electric motors

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

Modular Flameproof Brakes

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Safety valves direct, pilot operated and cartridge execution

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

Digital Pressure Regulator Sentronic PLUS Series 614

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

Compensation unit AGE-XY 50-80

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Bowl Feeder BF10 / BF15 Translation of original operating instruction

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

Ditec DOD Industrial sectional door automations

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Technical Guide No. 7. Dimensioning of a Drive system

PowerOhm Installation Manual for LG ATV Series Braking Modules

DYNATECH PROGRESSIVE SAFETY GEAR PR-2000-UD

ISTRUCTION MANUAL Italian Movements Italian Movements

Technical Documentation

OPERATION AND MAINTENANCE INSTRUCTIONS

GREENSTAR CANTIELEVER. User Guide. v4 - English

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

INSTRUCTIONS FOR INSTALLATION

ILED Dorado. User Manual

Pressure relief valve

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

MANUAL MACHINE BODY WITH INTERCHANGEABLE HEADS MU22N USE AND MAINTENANCE INSTRUCTIONS

Transcription:

MG300 USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6 Ver. 3.2 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11 Fax +39 059 31.58.90 Cap.Soc. 520.000 i.v. Export MO 004935 R.E.A. di MO N. 210108 Reg.Imprese di MO Cod.fisc. e Part.IVA n. 01047170368 Identification CEE No. IT 01047170368 www.montanari-giulio.com - E-mail: info@montanari-giulio.com

Aim The aim of this manual is to provide instructions for the correct installation, use and maintenance of the GEARLESS type MG300 and MGV30 for use in passenger and freight lifts. Warning: This booklet does not contemplate the instructions for the shutting down of the entire system, but only the instructions relating to the GEARLESS, therefore before starting the installation of the gearless you must follow the instructions in this operation and maintenance manual and take precautions in accordance with the current safety standards. The Gearless motors MG300 and all the components supplied by Montanari Giulio & C, have been tested in order to guarantee their correct operation. The Gearless motor has been tested in both empty and loaded operating conditions, in accordance with the technical specifications for velocity, car capacity load, car weight, presence or not of compensation and the type of roping requested when the order was placed. This ensures the correct operation and a minimum number of set-up operations. All responsibility is declined for any malfunctions due to installation with different characteristics, except in the case of specific approval by Montanari G. & C.

Summary: 1. References Standard 2 2. General notes 2 3. Transport 2 4. Warehouse storage 3 5. Installation 3 6. Brake 9 7. Use 13 8. Maintenance 13 9. Declaration of Conformity 14 10. Brake Certificate 15 1

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l 1 References Standard. 1.1 The following standards are to be considered as references and are not necessarily entirely applicable to this technical instruction. (Table 1) N Reference Type of standard Description 1 UNI 10147 E Maintenance : Terminology 2 UNI EN 81/1 E Safety rules for the construction and installation of passenger and freight lifts Table 1 2 General Notes. 2.1 The operations described in this manual must be carried out by qualified personnel, equipped with the necessary workshop tools. 2.2 Before all interventions the entire system must be put out of commission to prevent it from being used. 2.3 For all requests for spare parts or for particular instructions it is always necessary to specify the serial number, which can be found stamped next to the electrical connection terminal board. 3 Transport. 3.1 The entire gearless are packed in cases or crates. In some cases they are mounted upon wooden platforms, in order to be transported correctly on the lorry. The cases and crates are not load bearing and therefore cannot be stacked upon each other. 3.2 The unloading of the material, from the transport vehicle, must be done with equipment that is suitable for both the weight and the dimensions of the load. All the packing is designed for movement by fork lift and low lift platform trucks. 3.3 Upon the receipt of all material, check its condition. In the event of any damage do not proceed with the installation unless authorised otherwise by Montanari Giulio & C. 2

03/09/2012 Ver.3.2 4 Warehouse storage. 4.1 Preserve the gearless, even if it is still packed, in a dry place where it is protected from bad weather. 4.2 Once the packing has been removed take the necessary precautions to avoid the settling of any dust. 5 Installation. 5.1 Operating Conditions. - The gearless machine must be installed in a building or closed hoist-way. - Do not operate the gearless in an explosive atmosphere. - The ambient temperature must be within 0 C and +40 C. 5.2 Handling. The gearless can be lifted using the holes already present on the base for the fitting of belts or chains. (Figure N 1) Lifting sample: Figure 1 Care must be taken to ensure that the gearless doesn t get knocked as the brake disc, the brake calipers and the electrical connection terminal board is particularly delicate. 3

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l 5.3 Assembly and Dimension. The roping and therefore the load must always be orientated versus the base of the machine as shown in the diagram (Figure N 2 and figure N 3). In the case of assembly with the machine down, and therefore with the roping and load upward, you must mount it rotated by 180 degrees. Check that the gearless support base if perfectly flat, a tolerance of 0.1 mm is allowed. The flatness can be checked by placing the gearless on the base and then controlling that all the fastening points meet perfectly with the support surface. If this is not the case then suitable shims will need to be added. MGV30.4 Figure 2 4

03/09/2012 Ver.3.2 MGV30.6 Figure 3 5.4 Lubrication. The gearless does not contain oil and is supplied with bearings that are lubricated for the life of the equipment; therefore no further lubrication is necessary. 5

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l 5.5 Electric installation. Below the motor connector. The two clamps TR are connected to three PTC probes immersed within the coils of the gearless and they are used to control their temperature, connect them to the inverter or electrical control panel. The two clamps F1 and F2 are connected to the internal thermo contact that closing at 70 C start the fan. The clamp N is the star connection and must not to be connected. (See Picture below) [L1 L2 L3 - PE]= Power shield cable from motor to inverter [TR - TR]= Thermistors PTC [C]= Common terminal for Brake to Booster OUT- [BR BR]= Brake Supply terminals to Booster OUT+ [F1 - F2]= Fan supply direct to 230V AC (only MGV version) Table 2 Figure 4 The micro switch is representing from two contacts, one Normally Open (N.O.) and one Normally Close (N.C.). In rested state the gearless brake is closed and there isn t voltage between BR and C clamps (Figure 5). In this condition all lift system is motionless. When motor receive a command of moving, the brake change the status from closed to open and hence the micro switch does the same (Figure 6 and 7). 6

03/09/2012 Ver.3.2 Brake Closed Brake Open (Brake without Supply) Figure 5 Figure 6 Figure 7 Micro switch Contact Type Brake Closed Status Contact Contact Type Brake Open Status Contact N.O. -Black Blue Disconnected N.O. -Black Blue Connected N.C. - Black Grey Connected N.C. - Black Grey Disconnected Table 3 7

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l GEARLESS MG300 AND MGV30 TECHNICAL CHARACTERISTICS Motor Type Pn [kw] Speed [Rpm] Vn [V] Cn [Nm] In [A] Cmax [Nm] Imax [A] Emf [V*s/rad] Poles [n ] F [Hz] R [Ohm] L [H] St. Load [Kg] I [kgm^2] Duty Cycle Weight [Kg] Typical Installation MG300.4013000 3.5 48 360 700 12 1200 23 35 16 6.4 2.6 0.041 5500 2.24 40% 180s/h 435 500Kg 1:1 1m/s 400mm MGV30.4013000 5.4 48 360 1075 19.5 1500 28.5 35 16 6.4 2.6 0.041 5500 2.24 40% 180s/h 440 800Kg 1:1 1m/s 400mm MGV30.4023000 10.8 96 360 1075 32 1500 48 20 16 12.8 0.93 0.022 5500 2.24 40% 180s/h 440 1600Kg 2:1 1m/s 400mm MGV30.4033000 17.3 153 360 1075 47 1500 69 10 16 20.4 0.47 0.0109 5500 2.24 405 180s/h 440 1600Kg 2:1 1.6m/s 400mm MG300.6013000 6 48 360 1200 18 1800 28.5 37 16 6.4 1.7 0.029 5500 2.34 40% 180s/h 510 800Kg 1:1 1m/s 400mm MGV30.6013000 7.5 48 360 1500 23.5 2200 38.5 37 16 6.4 1.7 0.029 5500 2.34 40% 180s/h 520 1120Kg 1:1 1m/s 400mm MGV30.6023000 11.3 96 360 1500 39 2200 62 22 16 12.8 0.8 0.02 5500 2.34 40% 180s/h 520 2000Kg 2:1 1m/s 400mm MGV30.6023001 15 96 525 1500 30 2200 47 28 16 12.8 1.1 0.03 5500 2.34 40% 180s/h 520 1120Kg 1:1 1m/s 400mm MGV30.6033000 24 153 360 1500 61 2300 106 14 16 20.4 0.3 0.0074 5500 2.34 40% 180s/h 520 2000Kg 2:1 1.6m/s 400mm MGV30.6043000 30 191 360 1500 71 2350 124 13 16 25.5 0.22 0.0074 5500 2.34 40% 180s/h 520 2000Kg 2:1 2m/s 400mm Table 4 8

03/09/2012 Ver.3.2 6 Brake. 6.1 Brake characteristics. The brake has been designed in conformance with the specific requests of the EN81-1 standard; in particular it is in conformance with paragraph 9.10. This device is therefore usable as a brake to slow down the car in combination with a suitable speed governor, in the case of excessive velocity in the rising direction. The examination certificate is an DPS009 type and is issued by TÜV B.B. 6.2 Electrical Connection. The electro-magnet has 2 independent coils with parallel connection. Brake has to be supplied with Booster device in order to give 207 VDC for 1 second while opening and hold at 104 VDC. See Booster Basic Manual for further information (See Figure N 8 and Figure N 9). NOTE: for preserve the brake in presence of a contactor between booster and brake, connect two varistors (Example: S20K275). This component cut off the voltage peaks. Tension in over-excitation 207 Vdc, power of the single coil 270 W. Nominal tension 104 Vdc, power of the single coil 68 W. Figure 8 Booster Basic 9

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l Figure 9 6.3 Emergency manoeuvre. The emergency maneuver must be made by an independent electrical device, which is capable of opening the brake and moving the gearless at a reduced velocity or manually by brake release lever. It is possible to exploit the characteristics of the synchronous motor as it can slow down the car when the phases are put into short circuit. This system has some load limits and it is therefore necessary to observe several precautions. Montanari Giulio & C. can provide the information necessary to apply the aforementioned solution upon request. 10

03/09/2012 Ver.3.2 6.4 Brake adjustment. 1 a) Brake Torque The gripping jaws are calibrated by Montanari in order to be compliant to the EN81 standard par. 12.4.2 and appendix D.2. Screws (2) therefore don t require any further adjustment to change force. In Table 1 regulation value. 2 3 4 b) Brake Stroke The jaws must open with the minimum stroke possible to ensure that the braking material doesn t touch the brake drum whilst in motion. By tightening or loosening the regulation screws (1) the stroke can be lengthened or shortened. The stroke is calibrated by Montanari. In gearless machine wear on the brake pads is not common, anyway if space (5) from centre pad and drum, when brake open, is greater than 0.5mm then adjustment is required shortened the stroke unscrewing (1). The jaws must be replaced when the brake pads have a thickness 2 mm 5 c) Micro switch Thanks to the two micro switch (3) (4) with their NA and NC contacts a signal can be received to show whether the jaws of the relative brake are open and closed. (4) is used to check closing jaws while (3) is for the opening. Micro switches are already set. If you want to regulate micro switch you have to unscrew the two screws for each micro switch and move to the left or right in order to get the correct contact signal. The signal cables are situated on the motor connection box in a specific connector block. The contacts can withstand a maximum load of 250 Vca with 1A, for a mechanical duration of over 2 million operations. 11

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l L L Figure 10 Gearless Type: MG300.4 / MGV30.4 MG300.6 / MGV30.6 Brake Constant Torque K (Nm/mm) 57,1 57,1 No load length L = L0 (mm) 62 62 Max load length L = Lmin (mm) 35,7 20 Max breaking torque with Lmin (Nm) 1500 2400 Montanari Set (Nm) 1500 2400 Breaking Torque with different length L: Mtb = (L0- L) x K Table 5 12

03/09/2012 Ver.3.2 7 Use. 7.1 General notes. The gearless are designed and constructed as lifting devices for lifts and hoists and respect the various sector standards. Any other use is to be considered improper. They cannot be used in systems with characteristics that are different to those agreed upon in the order (e.g. carrying capacity, velocity, etc.), Qualified and competent personnel must carry out all tests, inspections or maneuvers that may be necessary in accordance with the current standards. 8 Maintenance. 8.1 Traction/Driving pulley. Periodically, at least once a year, check the amount of wear on the cable races on the traction pulley. In the event of the cables slipping or of excessive wear contact Montanari Giulio & C. for the substitution instructions, always indicating the serial number. 8.2 Brake. At least once a year check the amount of wear on the brake pads. 8.3 Component substitution. The instructions for any eventual component substitutions must be asked for each time from the Technical Department, specifying the serial number. 13

MG300 USER GUIDE MONTANARI GIULIO & C. S.r.l 9 Declaration of Conformity. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY (Directive 2006/42/CE, Annex II, par. B.) Manufacturer: Montanari Giulio & C. S.r.l. Via Bulgaria n.39, 41122 Modena Person authorized to compile the relevant technical documentation: Bertoni Stefano, Montanari Giulio & C. S.r.l., Via Bulgaria n.39, 41122 Modena Model of the partly completed machinery: Gearless: MG200 MGV25 MG25S MG300 MG34S MCG150 MDD35 - MDD70 The essential requirements of this Directive are applied a fulfilled and the relevant technical documentation is compiled in accordance with part B of Annex II. The partly completed machinery comply with the following directives: 95/16/CE, 89/336/CE, 92/31/CE, 73/23/CE The Montanari Giulio & C. S.r.l. undertakes to provide, in response to a reasoned request by national authorities, relevant information on the partly completed machinery. The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive: 2006/42/CE or 95/16/CE. Violation of the dispositions given in these technical instructions will immediately invalidate any form of guarantee Note: With regard to fulfilment of point 9.7 of reference regulation EN81-1 1998, please remember that Montanari supplies protection devices only if specifically requested by the customer. The responsible Ponanti Graziano Firma: Modena il 22/12/2009 14

03/09/2012 Ver.3.2 10 Brake Certificate. 15

MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11 Fax +39 059 31.58.90 Cap.Soc. 520.000 i.v. Export MO 004935 R.E.A. di MO N. 210108 Reg.Imprese di MO Cod.fisc. e Part.IVA n. 01047170368 Identification CEE No. IT 01047170368 www.montanari-giulio.com - E-mail: info@montanari-giulio.com