SQUARE D INDUSTRIAL CONTROL PRODUCTS

Similar documents
Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Applications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings

2006 Series Geared Rotary Limit Switches

Series Gemco. Rotating Cam Limit Switches. Micro-Adjust Cams. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information

SIGUARD Safety Systems Safety Integrated

the Interactive Catalog

2000 Series Geared Rotary Limit Switches

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms.

3SE3 2 SIGUARD Position Switches

Magnetic Overload Relays

Contents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

60T Series Snap-Action Temperature Controls

Safety Limit Switch

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 G1/4 8,5

Hazardous Factory Sealed Control Devices

the Interactive Catalog

S&C Switch Operators Types AS-1A and AS-10

Ch 4 Motor Control Devices

60T Series Snap-Action Temperature Controls

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

MODEL 10LH SPECIFICATION

Shock/Vibration Control Switches

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

the Interactive Catalog

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever)

System 350 P352AB Electronic Pressure Control Series

3SE03 North American Limit Switches

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Available as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

HQ Series ¼ Turn Electric Actuator

Robust General-Purpose Limit Switch WL

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

IEC Limit Switches Selection Guide

58T Series. Adjustable Temperature Controls. Adjustable Temperature Controls

Adjustable Torque Controls

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Easy Mounting and Wiring

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

ACCESS SOLUTIONS NEW PRODUCTS BROCHURE.

ED SERIES SAFETY LIMIT SWITCH

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

NEMA Frame. W Premium Brake Motors NEMA. Foot Mounted 3PH, 60 Hz Aluminum Construction /5T 4.5

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Geared Rotary Limit Switches SUPERIOR DESIGN AND OPERATING FEATURES ALL METAL GEARING FOR LONGEVITY

NEMA AC Motor C-Face Kits for Field Conversion

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

IEC Limit Switches Selection Guide

FL series position switches

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

W22 NEMA Brake Motors - NEMA Premium

Static Injection Timing

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

A25 Series Warm Air Control with Manual Reset

Bourdon Tube Pressure Switches

M-23A, M-23B, M-3 and Low-Clearance M-3 Switch Machines with MCC

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Rosemount 8750WB Magnetic Flowmeter System

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Safety Limit Switch

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

EStrong-series Emergency Stop

Position switches FR series

SECTION MOTOR CONTROL

HP Series. Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

Compact Limit Switches

Low Pressure Sensor. Overview. Specifications. Installation and Operation

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Section 11. Specialty Control Devices. Control Catalog 11-1

Order Toll-Free: Fax:

3SE03 North American Limit Switches

Electropneumatic Timing Relays Series 7000 Industrial

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Single and Three Phase General Purpose Motors

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

MF4E MF4E

Industrial and Commercial Duty IEC Motors

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

HL (AZH) LIMIT SWITCHES

SV60 Safety Valve Replacement Parts Fitting Instructions

Quick Start Guide TS 910

MC-351, 421, 431, MC-4311

Position switches FD series

Motor Accessories. NEMA AC Motor C-Face Kits for Field Conversion

Class 9038 Type A Mechanical Alternator, Open Tank

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Transcription:

SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS HEAVY DUTY LIMIT SWITCHES Types T and FT Robust, heavy duty switch 15 operating sequences available Most sequences are convertible in the field. Type T suitable for heavy duty applications. Type FT specifically designed for foundry and mill applications High contact ratings up to 20A Interchangeable base plates enable various mounting options Full range of heavy duty lever arms available Heavy Duty Limit Switches Type T... Limit Switches For Foundry Use Type FT... Operating Arms... Base Plates... Replacement Parts... Technical Data... Dimensions... 2 3 4 4 5 5 7 1

Class HEAVY DUTY LIMIT SWITCHES... Type T Universal Limit Switches Ingress Protection IP (IEC144) Lever Types Oil-Tight, Dust-Tight, Water Tight and Drip Tight Enclosure. NEMA Types 2, 4 and 13 Universal Type Switch Adjustable to 11 Different Operating Sequences Order Class Type... TUA 1 TUC 1 TUB 1 TUD 1 TUA 2 TUC 2 TUB 2 TUD 2 TUA 3 TUC 3 TUB 3 TUD 3 TUA 4 TUC 4 TUB 4 TUD 4 TUA 5 TUC 5 TUB 5 TUD 5 TUA TUC TUB TUD TUA 7 TUC 7 TUB 7 TUD 7 TUA 8 TUC 8 TUB 8 TUD 8 TUA 9 TUC 9 TUB 9 TUD 9 TUA 10 TUC 10 TUB 10 TUD 10 Lever arms...page 4 Technical data...page 5 Accessories...Page 5 Dimensions...Pages -7 Note: Preferred items shown in bold print. When fitted with suitable cable gland or adequately sealed conduit. Universal Type Switch, Non Adjustable, Maintained Contact Standard Type Switch Adjustable to 3 Different Operating Sequences TUA 11 TUC 11 TUB 11 TUD 11 TUA 12 TUC 12 TUB 12 TUD 12 TSA 1 TSC 1 TSB 1 TSD 1 TSA 2 TSC 2 TSB 2 TSD 2 TSA 3 TSC 3 TSB 3 TSD 3 * Maintained (Normal) Position A- A Contact Closed B- B Contact Closed O-Both Contacts Open --------Spring Return (Tripped) Position Third letter in Type indicates baseplate style. Select as required, see Page 2b for further details. ± If high speed cam or snap-back present, use maintained contact switch-sequence No. 12 A These operating sequences have slow make, slow break, contact action. Arm has spring return to inital position. Cam design must prevent fly-back action of operating arm. Contact position is maintained until arm is operated in reverse direction. Cam design must prevent fly-back action of operating arm. Eg: Class Type TUB-4 Order lever arm from Page 4 2

HEAVY DUTY LIMIT SWITCHES... Type FT Class Universal Limit Switches For Foundry Use Ingress Protection IP (IEC144) Lever Types Oil-Tight, Dust-Tight, Water Tight and Drip Tight Enclosure. NEMA Types 2, 4 and 13 Universal Type Switch Adjustable to 11 Different Operating Sequences Order Class Type... FTUA 1 FTUC 1 FTUB 1 FTUD 1 FTUA 2 FTUC 2 FTUB 2 FTUD 2 FTUA 3 FTUC 3 FTUB 3 FTUD 3 FTUA 4 FTUC 4 FTUB 4 FTUD 4 FTUA 5 FTUC 5 FTUB 5 FTUD 5 FTUA FTUC FTUB FTUD Type FTUB4 With D1 ARM FTUA 7 FTUC 7 FTUB 7 FTUD 7 FTUA 8 FTUC 8 FTUB 8 FTUD 8 FTUA 9 FTUC 9 FTUB 9 FTUD 9 FTUA 10 FTUC 10 FTUB 10 FTUD 10 FTUA 11 FTUC 11 FTUB 11 FTUD 11 Universal Type Switch, Non Adjustable, Maintained Contact Lever arms...page 4 Technical data...page 5 Accessories...Page 5 Dimensions...Pages -7 Note: Preferred items shown in bold print. When fitted with suitable cable gland or adequately sealed conduit. Standard Type Switch Adjustable to 3 Different Operating Sequences FTUA 12 FTUC 12 FTUB 12 FTUD 12 FTSA 1 FTSC 1 FTSB 1 FTSD 1 FTSA 2 FTSC 2 FTSB 2 FTSD 2 FTSA 3 FTSC 3 FTSB 3 FTSD 3 * Maintained (Normal) Position A- A Contact Closed B- B Contact Closed O-Both Contacts Open --------Spring Return (Tripped) Position Third letter in Type indicates baseplate style. Select as required, see Page 2b for further details. ± If high speed cam or snap-back present, use maintained contact switch-sequence No. 12 A These operating sequences have slow make, slow break, contact action. Arm has spring return to inital position. Cam design must prevent fly-back action of operating arm. Contact position is maintained until arm is operated in reverse direction. Cam design must prevent fly-back action of operating arm. Eg: Class Type FTUB-1 Order lever arm from Page 4 3

Class HEAVY DUTY LIMIT SWITCHES... Types T and FT Lever Arms And Base Plates Lever Arms For Types T and FT Straight Offset 90 Forked Length of Arm mm Straight 38 4 38 Lever Offset mm Roller Width mm Distance from Cam Track Order Class Type... mm (CL of Roller 19mm dia. 25mm dia. 35mm dia. Roller Position to Switch Base) Roller Roller Roller Optional Optional Optional Straight (Ball Bearing Roller) 13 43 or 2 43 or 2 40 or 5 B1 B7 B12* B2 B8 B13* 38 Centre 7 51 B1 (22mm diameter) Offset 38 10 Inside Offset 51 C1 C2 C3 Outside Offset 33 or 71 D1 D2 D3 48 21 Outside Offset 21 or 83 E4 E5 E Inside Offset 40 or 4 F4 F5 F B3 B9 B14* 120 Forked 90 Forked 38 Rollers on same side R.H. Roller on opp. side L.H. Roller on opp. side 43 or 2 43 and 2 43 and 2 X1 Y1 Z1 X2 Y2 Z2 120 Forked Rod or Key Stock 38 Rollers on same side R.H. Roller on opp. side L.H. Roller on opp. side 43 or 2 43 and 2 43 and 2 J1 K1 N1 J2 K2 N2 One Way Roller Rod Or Key Stock 37 Optional 0 or 79 R18 R19 R20 42 18 R17 One Way Roller Weld on 38 10 Outside Offset 71 D4 Weld On 89 G10 Base Plates for Types T and FT * Two mm Wide Rollers Roller head assembly for use with R17 arm and mm Key Stock. Order Class Style Mounting Holes Type... A B C D End Side End 2934-D32-G1A 2934-D14-G1A 2934-D33-G1A 2934-D34-G1A No mounting holes in base plate. Side mounting holes in switch case must be used. A Base plate without manifold. Technical Data... Page 5 Dimensions... Page 7 Eg: Class Type B1 4

HEAVY DUTY LIMIT SWITCHES... Types T and FT Class 9998 Technical Data and Replacement Parts Kits Replacement Parts and Accessories Use With Order Device Class 9998 Type Description Type... T and FT Replacement Contact kit for Types TS, TU, FTS and FTU E2934-S923-G1 T and FT Replacement Spring kit for Types Nos. 1 to 11 E2934-S925-G1 T and FT Replacement Gasket kit E2934-S92-G1 T Replacement Shaft kit for Type TU E2934-S928-G1 T Replacement Shaft kit for Type TS E2934-S929-G1 FT Replacement Shaft kit Type FTU E2934-S931-G1 T and FT Accessory Conduit Seal (5 hole) Class Type 31032-488-01 Technical Data Mechanical Data Operating Characteristics The overtravel figures shown are maximum values. It is recommended that 5 to 10 degrees overtravel be used to obtain the optimum mechanical life from the limit switch. The overtravel shown is a feature of the switch that allows for set up adjustment and emergency operation where excessive operating arm travel is encountered or required. The location of the operating arm may reduce the actual amount of overtravel due to interference with the switch enclosure. Repeat Accuracy Operating With Accuracy Type of Force Arm Length Switch to Trip mm mm Overtravel Standard 10cm-kg 38 ±0.05 73 Universal 1m-kg* 38 ±0.05 74 * Except TU-7 & 8 which require 2.9cm-kg and TU-12 which require 9cm-kg. Nominal value. Overtravel varies with operating sequence. Cam Track Data Electrical Ratings DC AC Pilot Duty Pilot Contact AC Amperes DC Duty Arrangement Volts Break Make Volts Amps Single Pole 120 20 150 125 5.0 Double Throw 240 12.5 75 250 1.0 480.25 37.5 00 0.2 00 5 30 Operating Sequence No. 12 maintained contact action. All positions can be reversed. Clockwise operation, counterclockwise reset shown. Note: Electrical ratings apply when switch is operated with quick make and break contact action. If latches are removed to obtain slow make and break action the switch has the following pilot duty rating: 20-125 volts A.C. of amperes and 125-00 volts A.C. of 720 VA. A.C. Pilot duty rating is based on a 0.35 power factor. D.C. Pilot duty rating is based on inductive loads such as coils and solenoids. Eg: Class 9998 Type E2934-S925-G1 5

Class HEAVY DUTY LIMIT SWITCHES... Types T and FT Dimensions Limit Switches Limit Switches Types T and FT Base Plate Dimensions Style B (Style E with Manifold Opening) Style C (Style F with Manifold Opening) Style D (Style G with Manifold Opening) Limit Switches Types T Limit Switches Type FT Dimensions in mm

HEAVY DUTY LIMIT SWITCHES... Types T AND FT Class Dimensions Lever Arms Straight Arms Arm Type A B C D E B1 38 19 10 23 B2 38 25 10 23 B3 38 35 10 23 B7 4 19 10 23 B8 4 25 10 23 B9 4 35 10 13* 23 B12 38 19 13 13* 29 B13 38 25 13 13* 29 B14 38 35 13 13* 29 Offset Arms Type R18, R19, R20 Arms * Two mm wide rollers Inside Offset Arm Types A B C D E F C1 38 19 0 10 25 C2 38 25 0 10 25 C3 38 35 0 10 25 F4 48 19 12 21 37 F5 48 25 12 21 37 F 48 35 12 21 37 Outside Offset Arm Types A B C D E F D1 38 19 19 10 33 D2 38 25 19 10 33 D3 38 35 19 10 33 E4 48 19 31 21 44 E5 48 25 31 21 44 E 48 35 31 21 44 Type R17 Key Stock Type Arm Arm Type Dimension B R18 19 R19 25 R20 35 90 Forked Arms 120 Forked Arms Note: Rollers are removable making it possible to reverse their position on the arm. Types B1 & D4 Arms Type G10 Weld-On Arm Type Dimension A X1, Y1, Z1 19 X2, Y2, Z2 25 All Dimensions in Millimetres 7