3RT14 Contactors with 3 Main Contacts

Similar documents
Technical specifications

SIRIUS. Answers for industry.

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

3NP1 Fuse Switch Disconnectors up to 630 A

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

SIRIUS 3RU2 Thermal Overload Relays

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

SENTRON Switching and Protection Devices Switch Disconnectors

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Micro Contactor MA Series

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Technical Information

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

For Operation in the Control Cabinet

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Contactor Types CI 61-98

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

BETA Switching Switches and Light Indicators

CI-TI Contactors and motor starters Types CI 61 - CI 98

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

For Operation in the Control Cabinet

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Leadership driven by innovation

3VU13, 3VU16 Circuit-Breakers

TAE pole Contactors

Mini Contactors CI 4-

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Protection Equipment

AF40... AF96 3-pole contactors Technical data

Technical Information

Manual Motor Protectors

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

All round protection guaranteed

AE 9... AE 40 Contactors NE... Contactor Relays

Series CA5 Contactors

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

4 - Miniature controls

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Thermal Overload Relays - WEG RW Series, 2 Pole

Low-Voltage Controls and Distribution

Capacitor Switching Contactors Type K3...-A, K3...-K

AF series contactors (9 2650)

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Protection Equipment. 5/2 Introduction

Technical Information

Contactor Relays 3TH30

AF series contactors (9 2650)

Control Circuit Protection

Industrial Contactors CTX 3 3P 185A - 800A

44 SERIES. PCB/Plug-in relays from 6 to 10 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Components for EEx e Panels

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

Miniature Circuit-Breakers (MCBs)

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

General purpose relays 7-10 A

Essential equipment for all your requirements

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Page 2-4 Page 2-8. Page Page 2-12

Protective Devices: Circuit-Breakers 1 )

General technical data. Ambient conditions

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

SWITCH FUSES 3KL71 from 32A to 800A Description

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

CI-TI Contactors and Motor Starters Type CI 6-50

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

C -5 to +55 (0.8 to 1.1Uc) Permissible o

3SE3 1 SIGUARD Position Switches

Phone: Fax: Web: -

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Solid State Relays, 3-phase

BETA Low-Voltage Circuit Protection

Miniature Industrial relay 8-16 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

ASL09..S 3-pole Contactors - Spring Terminals

The contactor for large horsepower applications

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Bulletin 100-D IEC Contactors

Description. Positive safety relays

Series CA6 Contactors

Transcription:

3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e Rated insulation voltage U i (pollution degree 3) V 1000 Permissible ambient temperature in operation when stored to +60 55 to +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 IP 20 (terminal compartment IP 00), coil system IP 40 Coil voltage tolerance C/DC 0.8 to 1.1 x U s Power consumption of the coils (with coil in cold state and 1.0 x U s ) Standard design For US and Canada C operation Hz 50 50/60 50 60 closing closed DC operation closing = closed W 15 Operating times at 0.8 to 1.1 x U s 1) Break time = opening time + arcing time C operation closing time opening time 17 to 90 10 to DC operation closing time opening time V V 270 298 /274 218 232 0.68 0.7 / 0.62 0.61 0.55 22 27 / 20 21 20 0.27 0.29/ 0.31 0.26 0.28 90 to 230 14 to 20 rcing time 10 to 15 Operating times at 1.0 x U s 1) C operation DC operation closing time opening time closing time opening time 18 to 30 11 to 23 100 to 120 16 to 20 Shock resistance Rectangular pulse C and DC operation g/ 6.8/5 and 4/10 Sine pulse C and DC operation g/ 10.6/5 and 6.2/10 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N of coord. "1" 2 ) 0 Fuse links, utilization category gr SITOR 3NE of coord. "2" 2 ) 0 Control circuit (short-circuit current I k 1 k) Fuse links, utilization category gl/gg DIZED 5SB 10 NEOZED 5SE 10 Miniature circuit-breaker with C-characteristic 10 Operating frequency Operating frequency z in operating per hour C operation DC operation Contactors without overload relays No-load operating 1/h 5000 1000 frequency Rated operation for C-1 1/h 0 0 for C-3 1/h 1000 1000 Dependence of the operating frequency z on the rated operational current and the rated operational voltage: I z = z --- e 400V ----------- 1.5 1/h I U 1) The opening times of the NO contacts and the closing times of the NC contacts increase if the contactor coils are protected against voltage peaks (varistor +2 to 5, diode assemblies 2 to 6 times). 2) ccording to excerpt from IEC 60 947-4-1 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/74 Siemens NS K 2000

3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Conductor cross-sections Contactor Size 3RT14 46 Screw connections (1 or 2 conductor connections possible) Connection for drilled copper bars Without box terminal With cable lugs (1 or 2 conductor connections possible) Main conductor: Front terminal Back terminal Both terminals with box terminal (acc. to EN 50 027) connected connected connected Finely stranded with end sleeve mm 2 2.5 to 50 2.5to 50 max. 2 x Finely stranded without end sleeve mm 2 4 to 50 10 to 50 max. 2 x Solid mm 2 2.5 to 16 2.5 to 16 max. 2 x 16 Stranded mm 2 4 to 70 10 to 70 max. 2 x 50 Ribbon cable (no. x width x thickness) mm 6 x 9 x 0.8 6 x 9 x 0.8 2 x (6 x 9 x 0.8) WG conductor connections WG 10 to 2/0 10 to 2/0 max. 2 x 1/0 Max. conductor cross-sections mm 18 x 10 If bars larger than 12 x 10 mm are connected, a 3RT19 46-4E1 terminal cover is necessary to comply with the phase clearance Finely stranded with cable lug mm 2 10 to 50 If conductors larger than mm 2 are Stranded with cable lug mm 2 10 to 70 connected, a 3RT19 46-4E1 terminal cover is necessary to comply with the WG conductor connections, solid or stranded WG 7 to 1/0 phase clearance Terminal screws M6 (hexagon socket) Tightening torque Nm 4 to 6 (36 to 53 lb.in) uxiliary conductor: Solid mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5) acc. to IEC 60 947; max. 2 x (0.75 to 4) Finely stranded with end sleeve mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5) WG conductor connections, solid or stranded WG 2 x (18 to 14) Terminal screws M3 Tightening torque Nm 0.8 to 1.2 (7 to 10.3 lb.in) Load ratings with C C-1 utilization category, switching resistive load Rated operational currents I e of three-phase loads = 1 (at 60 ) at 40 up to at 60 up to at 1000 V 1000 V Minimum conductor cross-section with I e load at 40 at 60 C-2 and C-3 utilization categories With an electrical endurance of 1.3 million operating 140 50 50 86 113 149 86 mm 2 50 mm 2 50 Rated operational current I e up to 44 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz (at 60 ) 12.7 22 29.9 38.2 Load ratings with DC DC-1 utilization category, switching resistive load L/R 1 ) Number of conducting paths connected in series 1 2 3 Rated operational currents I e (at 60 ) 600 V 80 12 2.5 0.8 0.48 13 2.4 1.3 DC-3 and DC-5 utilization categories, shunt and series motors Number of conducting paths connected in series 1 2 3 Rated operational currents I e (at 60 ) 600 V Thermal load 10 s current 1 ) 630 Power loss per conducting path at I e /C-1 W 12.5 6 3 1. 0. 0.15 0.1 1.75 0.42 0.27 6 3.4 4 0.8 0.45 1) cc. to VDE 0660 Part 102. Siemens NS K 2000 3/75

3RT13 Contactors with 4 Main Contacts for Switching Resistive Loads Contactor Size (for 0, see page 3/58) 3RT13 /26 S2 3RT13 36 3RT13 44 3RT13 46 Mechanical endurance Oper. 10 million Electrical endurance at I e /C-1 Oper. approx. 0.5 mill. Rated insulation voltage U i (pollution degree 3) V 690 690 1000 1000 Permissible ambient temperature in operation when stored to +60 55 to +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 terminal compartment IP 20 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 Power consumption of the coils (with coil in cold state and 1.0 x U s ) C operation Hz 50 50/60 50 50/60 50 50/60 50 50/60 closing closed V 61 64/63 0.82 0.82/0.74 V 7.8 8.4/6.8 0.24 0.24/0.28 127 127/160 0.82 0.82/0.85 13.5 13.5/14.2 0.34 0.34/0.37 270 298/274 0.68 0.72/0.62 22 27/20 0.27 0.29/0.31 DC operation closing = closed W 5.6 11.5 15 15 Coil voltage tolerance 0.8 to 1.1 x U s Operating times at 0.8 to 1.1 x U s Break time = opening time + arcing time C/DC operation closing time 6 to 30/ 30 to 90 C/DC operation opening time 13 to / 13 to 40 4 to / 50 to 110 10 to 30/ 15 to 30 20 to 50/ 110 to 200 10 to / 14 to 20 270 298/274 0.68 0.72/0.62 22 27/20 0.27 0.29/0.31 20 to 60/ 110 to 200 10 to / 14 to 20 rcing time 10 to 15 10 to 15 10 to 15 10 to 15 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE acc. to IEC 60 947-4/ EN 60 947-4-1 (VDE 0660 Part 102) of coord. "1" 1 ) 63 160 0 0 of coord. "2" 1 ) 63 1 160 Weld-free 16 50 63 100 1) ccording to excerpt from IEC 60 947-4 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/76 Siemens NS K 2000

3RT13 Contactors with 4 Main Contacts for Switching Resistive Loads Load ratings with C Contactor Size (for 0, see page 3/58) 3RT13 /26 S2 3RT13 36 3RT13 44 3RT13 46 C-1 utilization category, switching resistive load Rated operational currents I e (at 40 ) up to 33/40 60 100 140 of three-phase loads = 0.95 (at 40 ) 12.5/15 22/26 Minimum conductor cross-section with I e load at 40 mm 2 10/10 16 50 50 C-2 and C-3 utilization categories Rated operational currents I e (at 60 ) at 17/ 26 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz 4/5,5 7.5/11 22 39 5.5 11 37 53 92 Load ratings with DC DC-1 utilization category, switching resistive load (L/R 1 ) Rated operational currents I e (at 40 ) DC-3 and DC-5 utilization categories, shunt and series motors (L/R 15 ) Rated operational currents I e (at 40 ) Number of conducting paths connected in series Number of conducting paths connected in series 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 50 50 50 50 70 70 70 70 80 80 80 80 20 23 45 45 45 23 70 70 70 60 80 80 80 4.5 4.5 45 45 45 4.5 70 70 70 9 80 80 80 1 5 1 5 45 45 1 5 70 70 2 10 80 80 0.4 1 2.9 2.9 0.4 1 2.9 2.9 0.4 1 2.9 2.9 0.6 1.8 4.5 4.5 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 20 20 45 45 45 20 70 70 70 20 80 80 80 2 2 45 45 45 2 70 70 70 2.3 80 80 80 0.75 7 0.75 7 45 45 0.75 9.4 70 70 0.9 80 80 80 0.2 1 3.5 3.5 0.2 1 3.5 3.5 0.2 1 3.5 3.5 0.26 1.3 3.5 3.5 0.09 0.27 0.6 0.6 0.09 0.3 0.6 0.6 0.09 0.27 0.5 0.6 0.11 0.3 0.6 0.6 Siemens NS K 2000 3/77

3RT15 Contactors with 4 Main Contacts for Switching Motors Contactor Size (for 0, see page 3/58) 3RT15 26 S2 3RT15 Mechanical endurance Oper. 10 million Electrical endurance at I e /C-1 Oper. approx. 0.5 million Rated insulation voltage U i (pollution degree 3) V 690 Permissible ambient temperature in operation when stored to +60 55 to +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 IP 20 IP 20 (term. compartment IP 00) Power consumption of the coils (with coil in cold state and 1.1 x U s ) C operation Hz 50 50/60 50 50/60 closing closed V 61 64 /63 0.82 0.82/ 0.74 V 7.8 8.4 / 6.8 0.24 0.24/ 0.28 DC operation closing = closed W 5.6 11.5 Coil voltage tolerance 0.8 to 1.1 x U s Operating times at 0.8 to 1.1 x U s Break time = opening time + arcing time 127 127 /160 0.82 0.82/ 0.85 13.5 13.5 / 14.2 0.34 0.34/ 0.37 C/DC operation closing time 6 to 30/30 to 90 4 to /50 to 110 C/DC operation opening time 13 to /13 to 40 10 to 30/15 to 30 rcing time 10 to 15 10 to 15 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE acc. to IEC 60 947-4-1/ EN 60 947-4-1 (VDE 0660 Part 102) of coord. "1" 1 ) of coord. "2" 1 ) Weld-free 63 16 160 80 50 1) ccording to excerpt from IEC 60 947-4-1 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overlaod relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/78 Siemens NS K 2000

3RT15 Contactors with 4 Main Contacts for Switching Motors Load ratings with C Contactor Size 3RT15 26 S2 3RT15 C-1 utilization category, switching resistive load Rated operational currents I e (at 40 ) up to 40 55 of three-phase loads = 0.95 (at 40 ) Minimum conductor cross-section with I e load at 40 mm 2 10 16 C-2 and C-3 utilization categories Rated operational currents I e (at 60 ) up to 40 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz and 15 26 5.5 11 20 36 9.5 18.5 Load ratings with DC DC-1 utilization category, switching resistive load (L/R 1 ) Rated operational current I e (at 60 ) Number of conducting paths connected in series 1 2 1 2 DC-3 and DC-5 utilization categories, shunt and series motors (L/R 15 ) Rated operational current I e (at 60 ) 600 V 20 4.5 1 5 0.4 1 0. 0.8 55 55 23 45 4.5 45 1 5 0.4 1 0. 0.8 Number of conducting paths connected in series 1 2 1 2 600 V 20 5 2.5 15 1 3 0.09 0.27 0.06 0.16 80 6 45 2.5 1 5 0.1 0.27 0.06 0.16 Siemens NS K 2000 3/79

3RT16 Capacitor Contactors ll technical data not mentioned in the table below is identical to that of the 3RT10 26 contactors for size, to that of the 3RT10 36 contactors for size S2 and to that of the 3RT10 45 contactors for size. Contactor Size 3RT16 26 S2 3RT16 36 3RT16 46 Capacitor rating for operational voltage 230 V 50/60 Hz 50/60 Hz 5 V 50/60 Hz 50/60 Hz uxiliary contacts mounted (unassigned) dditional auxiliary contacts mountable (laterally) kvar kvar kvar kvar 8.5 15 20 1 NO 2 NC, 2 NO or 1 NO + 1 NC 0.85 to 1.1 x U s Coil voltage tolerance Max. operating frequency 1/h 180 100 100 Electrical endurance Oper. > 100 000 mbient temperature 60 55 55 Specifications IEC 60 947/EN 60 947 (VDE 0660) 14 32 32 29 50 3RT10 Coupling Relays (Interface) for Switching Motors ll technical data not mentioned in the table below is identical to that of the 3RT10 contactors for switching motors listed on page 3/44 onwards. The 3RT10 1. coupling relays cannot be extended with auxiliary switch blocks. Two single-pole auxiliary switch blocks can be mounted onto the 3RT10 2. coupling relays (see accessories on page 3/19). Contactor Size 0 3RT10 1.-1HB4. 0 3RT10 1.-1JB4. 0 3RT10 1.-1KB4. 3RT10 2.-1KB40 Mechanical endurance Oper. 30 million 30 million 30 million 10 million Coil voltage tolerance 0.7 to 1. x U s q 17 V to 30 V Power consumption of the coil (with coil in cold state) at U s 17 V W 1.2 1.2 1.2 2.1 24 V W 2.3 2.3 2.3 4.2 closing = closed 30 V W 3.6 3.6 3.6 6.6 Permissible residual current of the electronics (with 0 signal) m < 10 m x 24 V --------- < 10 m x < 10 m x < 6 m x U s --------- V U s 24 --------- V 24 V --------- U s U s Surge suppression in the coil no surge suppression with diode with varistor with varistor Operating times of the coupling relays Closing at 17 V Closing time NO Opening time NC 40 to 120 30 to 70 40 to 120 30 to 70 40 to 120 30 to 70 93 to 270 83 to 0 at 24 V Closing time NO Opening time NC 30 to 60 20 to 40 30 to 60 20 to 40 30 to 60 20 to 40 64 to 87 55 to 78 at 30 V Closing time NO Opening time NC 20 to 50 15 to 30 20 to 50 15 to 30 20 to 50 15 to 30 53 to 64 45 to 56 Opening at 17 V to 30 V Closing time NO Opening time NC 7 to 17 22 to 30 40 to 60 60 to 70 7 to 17 22 to 30 18 to 19 24 to 3/80 Siemens NS K 2000

ccessories for 3RT1. Contactors acc. to IEC 61 812-1/DIN VDE 04 Part 2021 Solid-state time-delay blocks with semiconductor output 3RT19.6-2C 2D Rated insulation voltage C V 0 0 Pollution degree 3 Overvoltage category III acc. to DIN VDE 0110 Solid-state time-delay auxilary switch blocks 3RT19.6-2E 2F 2G Coil voltage tolerance 0.8 to 1.1 x U s 0.85 to 1.1 x U s 0.95 to 1.05 times 0.95 to 1.05 times rated frequency rated frequency Power consumption at C 230 V, 50 Hz Rated operational currents I e C-140, DC-13 C-15 at C 230 V, 50 Hz DC-13 at 24 V DC-13 at DC-13 W V 1 1 0.3 for 3RT19 16 0.5 for 3RT19 26 DIZED fuse protection Utilization category gl/gg 4 Operating frequency with I e load, C 230 V with 3RT1016 contactor load, C 230 V Recovery time 50 150 Minimum ON-period 200 (with OFF-delay) Residual current m w 5 1/h 1/h 00 00 2 4 3 1 0.2 0.1 00 5000 Voltage drop switched through V w 3.5 Short-time current-carrying capacity 10 (up to 10 ) Setting accuracy w & 15% w & 15% referred to upper limit of scale Repeat accuracy w & 1% w & 1% Mechanical endurance operating 100 x 10 6 30 x 10 6 Permissible ambient temperature Degree of protection acc. to IEC 60 529 in operation when stored to +60 40 to +85 IP 40 terminals IP 20 to +60 40 to +85 IP 40 terminals IP 20 Conductor connection solid mm 2 2 x (0.5 to 1.5) 2 x (0.75 to 4) 2 x (0.5 to 1.5) 2 x (0.75 to 4) finely stranded with end sleeve mm 2 2 x (0.5 to 2.5) 2 x (0.5 to 2.5) solid or stranded WG 2 x (18 to 14) 2 x (18 to 14) Terminal screw M3 M3 Tightening torque Nm 0.8 to 1.2 0.8 to 1.2 Permissible mounting position any any Shock resistance Half sine acc. to IEC 60 068-2-27 g/ 15/11 15/11 Vibration resistance acc. to IEC 60 068-2-6 Hz/mm 10 to 55/0. 10 to 55/0. EMC tests basic specification EN 50 081-1; EN 50 082-2 EN 50 081-1; EN 50 082-2 Surge suppression varistor integrated in time-delay relay Siemens NS K 2000 3/81

3R13 Reversing Contactor ssemblies The technical data is identical to that of the 3RT10.. contactors listed on page 3/54 onwards. The s and u approvals only apply to the complete contactor assemblies and not to the components for customer assembly. 3R14 Contactor ssemblies for Star-Delta Starting acc. to IEC 60 947-4-1 and VDE 0660 Part 102 Short-circuit protection with fuses for motor feeders with short-circuit currents up to 50 k and. For thermally delayed overload relays, see Part 4. Size of contactors K1-K3-K2 Rated motor current Overload relay Setting range Permissible short-circuit fuses for starters, comprising contactor assemblies and overload relays (the overload relays must be set to 0.58 times the rated motor current) Single or double infeed 2 ) Fuse links NH 3N NH TYP 3ND u-listed British DIZED 5SB Utilization cat. fuses Standard NEOZED 5SE am CLSS fuses Utilization cat. gl/gg K5 BS88 of coord. 1 ) of coord. 1 ) of coord. 1 ) "1" "2" "2" "1" "2" 5.5 0-0-0 12 3RU11 16-1HB0 5.5 to 8 20 10 30 20 7.5 0-0-0 17 3RU11 16-1JB0 7 to 10 20 16 40 20 11 -- 3RU11 26-4B0 11 to 16 63 20 60 63 15 -- 32 3RU11 26-4BB0 14 to 20 100 20 80 100 18.5 -- 40 3RU11 26-4DB0 20 to 100 20 100 100 22 S2-S2-50 3RU11 36-4EB0 22 to 32 1 63 1 1 63 30 S2-S2-3RU11 36-4FB0 28 to 40 1 63 50 150 1 63 37 S2-S2-S2 80 3RU11 36-4GB0 36 to 45 1 63 50 175 1 63 45 S2-S2-S2 86 3RU11 36-4HB0 40 to 50 160 80 50 200 160 80 55 --S2 115 3RU11 46-4KB0 to 75 0 1 63 300 0 1 75 --S2 150 3RU11 46-4LB0 70 to 90 0 160 80 0 0 160 1) ccording to IEC 60 947-4 -1 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 2) The maximum rated motor current must not be exceeded. 3/82 Siemens NS K 2000

3R14 Contactor ssemblies for Star-Delta Starting ll technical data not mentioned in the table below is identical to that of the individual 3RT contactors and the 3RU time-delay relays. Starters Sizes S.. - S.. - S.. 3R.... 00-00-00 14 15 00-00-00 14 16 0-0-0 14 23 0-0-0 14 2-2-0 14 34 2-2-2 14 2-2-2 14 36 3-3-2 14 44 3-3-2 14 45 Mechanical endurance Oper. 3 million Short-circuit protection without overload relay For short-circuit protection with overload relay, see Part 4. Maximum rated current of the fuse Main circuit 1 ) Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE Single or double infeed acc. to IEC 60 947-4-1/ DIN VDE 0660 Part 102 of coord. "1" 1 ) of coord. "2" 1 ) 20 20 63 100 1 63 1 63 160 80 0 1 0 160 Control circuit Fuse links, utilization category gl/gg DIZED 5SB, NEOZED 5SE (short-circuit current I k 1 k) Miniature circuit-breaker with C-characteristic Size of contactors Unassigned auxiliary contacts of the contactors Line Delta Star Load rating with C-3 utilization category Reversing time up to 10 s Rated operational current of three-phase motors at 50 Hz and K1 K3 K2 3RT 10 15 3RT 10 15 3RT 10 15 10, 6 2 ) if the auxiliary contact of the overload relay is connected in the contactor coil circuit 10, 6 2 ) if the auxiliary contact of the overload relay is connected in the contactor coil circuit 10 17 10 17 10 15 See circuit diagra of the control circuit on page 3/93. at 1000 V 12 8.7 3.3 5.3 17 11.3 9 4.7 8.2 7.5 10 24 10 24 10 24 7.2 12.5 13 18 10 26 10 26 10 24 40 31.2 22.5 12 21 20.5 20.4 10 34 10 34 10 26 55.4 53.7 20.4 38 51 10 10 10 34 80 69.3 69.3.5 44 48 66 10 36 10 36 10 34 86 86 69.3 27.8 48 60 67 10 44 10 44 10 115 112.6 98.7 37 80 97 Operating frequency with overload relay 1/h 15 15 15 15 15 15 15 15 15 Load rating with C-3 utilization category Reversing time up to 15 s Rated operational current of three-phase motors at 50 Hz and at 1000 V 12 8.7 3.3 5.3 Operating frequency with overload relay 1/h 15 15 15 15 15 15 15 15 15 Load rating with C-3 utilization category Reversing time up to 20 s Rated operational current of three-phase motors at 50 Hz and at 1000 V 12 8.7 3.3 5.3 Operating frequency with overload relay 1/h 15 15 15 15 15 15 15 15 15 17 11.3 9 4.7 8.2 7.5 17 11.3 9 4.7 8.2 7.5 7.2 12.5 13 18 7.2 12.5 13 18 31 31 22.5 9.4 16.3 20.4 20.4 28 28 22.5 8.5 14.7 18.4 20.4 44 44 44 13.8 24 30 42 39 39 39 12.2 21.3 26.7 37 18.2 31.6 40 55 51 51 51 16.3 28 49 67 67 67 21.6 38 47 18.4 32 40 55 97 97 97 32 55 69 95 85 85 85 28 48 60 83 10 45 10 45 10 36 150 138.6 138.6 49 85 98 136 106 106 106 60 75 104 92 92 92 30 52 90 1) ccording to IEC 60 947-4-1 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 2) Up to I k 0.5 k; 2. Siemens NS K 2000 3/83