PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Similar documents
Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

L Protection ATEX Explosion Protection Catalogue Version 03

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

PHOENIX CONTACT - 01/2008

Safety technique. Emergency Stop Module BH 5928, BI 5928

L Protection ATEX. Explosion Protection Catalogue Version 05

Electronic Braking Systems

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Solenoid interlock AZM 200 The non-contact interlock.

Safety Sensor CSS 180 Product Information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Lexium integrated drives

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

AZM 161SK 12/12RKED/TU 024

Lexium integrated drives

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Safety Control HR1S-AC. Safety Relay HR1S-AC

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Solenoid Valves Type 3963

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Solenoid Valve Island Type 3965

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Guard locking systems for the protection of man and machine

Safety door-handle system STS

Description. Positive safety relays

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Technical data for manual motor starters Type MS325

Pressure Transmitters

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Explosion-Protected Pressure Switches

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Safety Standards. Model Number:

Capacitive level sensors CLS 23

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Scheda prodotto Relè Series B

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

KINAX SR 709 Transmitter for Position Feedback

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Thermal overload relay TF65 and TF96

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Position Switches Series 8060/2

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Technical Data. Dimensions

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Electronic overload relay EF65, EF96 and EF146

Level Measurement Point level measurement - RF Capacitance switches

Solid State Relays, 3-phase

Electronic overload relays EF205 and EF370

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Alarm contacts for pressure gauges and thermometers

Compact System NRGS 11-2 NRGS Original Installation Instructions English

DC/DC converters - MINI-PS DC/ 5-15DC/

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

General_technical_data Series

Maintained selector switches, spring return selector switches with short or long knob

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Solenoid Operator 0516 / 1216

Possible to create the highest level safety system

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Operating instructions Solenoid interlock AZM 170

Braking Devices BR 230/ Assembly- and Commissioning Instructions

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

AF40... AF96 3-pole contactors Technical data

Electronic Circuit Breaker ESS20-0..

Transcription:

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i Protect SRB s ATEX certified For emergency stop and guard monitoring The new generation of safety relay modules SRB EXi combines the approved safety technique with the demands of the explosion protection. The SRB EXi modules are developed on the basics of the ATEX directive 94/9/EG and the European standards EN 60 079 et seq. The intrinsically safe monitoring guards Ex i are designed for equipment of the category 2GD. Therewith emergency stop devices and safety door monitorings may be used in gas- and dust-explosive atmosphere. Explosion protection ATEX ATEX category (2)GD for connection of devices from zones 1 or 21. ATEX category 3G allows installation of SRB EXi s in gas-zone 2. Safety-related function SRB 101EXi-1R 1 safety enabling output Stop 0 1 auxiliary contact cross-short detection (optional) monitored reset function SRB 101EXi-1A 1 safety enabling output Stop 0 1 auxiliary contact cross-short detection (optional) automatic and manual reset function SRB 200 EXi-1R 2 safety enabling output Stop 0 cross-short detection (optional) monitored reset function SRB 200 EXi-1A 2 safety enabling output Stop 0 cross-short detection (optional) automatic and manual reset function Dimension of intrinsic safety circuits Ex i [Ex i] U o I i I o P i P o C i + C K cable C o L i + L K cable L o Resistance (bidirectional)* Capacity* Inductivity* * Approximate values 0.5 mm 2 72 ohm/km 0.75 mm 2 48 ohm/km 1.5 mm 2 24 ohm/km 180 200 nf/km 0.8 1 mh/km Gas Dust L category 1 Zone 2 Definition explosive atmosphere Zone 2 L category 1 1G 0 Continuous, long periods, frequent 20 1D 2G 1 Occasional 21 2D 3G 2 Normally not, only for short periods 22 3D 1) Manufacturer: 94/9/EG = ATEX directive 2) User: 1999/92/EG = ATEX directive 2

PROTECT SRB s ATEX use in hazardous areas Ex-relevant technical data EC type test examination/ type examination test TÜV 08 ATEX 7522 / TÜV 08 ATEX 7557 Group, category, type of protection Gas: L II 3 G Ex nanc IIC T5 (SRB in zone 2) Gas/dust: L II (2) GD [Ex ib] IIC/[Ex ibd] (electric circuits in zones 1, 21/2, 22) Safety-related maximum current U m Inputs (S11-S12, S21-S22, X1-X2/X3) Temperature class Max. output voltage U o Current I o Max. output power P o Isolation (intrinsically safe/other circuits) 253 VAC (Attention: U m is nt rated voltage!) [Ex ib] IIC/[Ex ibd] T5 33.6 V 57.0 ma 478.8 mw (characteristic curve linear) safe isolation acc. to EN 60 079-11:2007, voltage peak value 375 V Group, category II C II B External capacitance C o (nf) 26 36 46 49 160 180 230 280 350 412 External inductance L o (mh) 4.0 2.0 1.0 0.5 38.0 5.0 2.0 1.0 0.5 0.2 Reference value of a circuit: C = 200 nf/km, L = 1 mh/km (C = 200 pf/m, L = 1 µh/m) Simple apparatus In connection with the intrinsically safe safety relay modules the following reset buttons, emergency stop control devices, locking devices and safety magnet switches can be used in intrinsically safe electric circuits as simple apparatus (acc. EN 60 079-11): Reset buttons (Elan Schaltelemente GmbH & Co. KG) Ex-RDT... Ex-RDM... Emergency stop control devices (Elan Schaltelemente GmbH & Co. KG) Ex-RDRZ... For reset buttons and emergency stop control devices we recommend the use of mounting boxes (Elan Schaltelemente GmbH & Co. KG): Ex-EBG 331.0 Ex-EBG 633.0 Locking devices (K.A. Schmersal GmbH) EX-AZ 17-...-3D EX-AZ 16-...-3D EX-AZ 336-...-3D EX-AZ 356-...-3D EX-AZ 415-...-3D EX-AZ 3350-...-3D EX-Z/T 235-...-3D EX-Z/T 335-...-3D Safety magnet switches (K.A. Schmersal GmbH) EX-BNS 33-...-3G/D, without LED version EX-BNS 120-...-3G/D, without LED version EX-BNS 180-...-3G/D EX-BNS 303-...-3G/D, without LED version EX-BN 20-...-3G/D 3

PROTECT SRB 101EXi-1A,...-1R for emergency stop- and guard monitoring SRB 101EXi-1A/-1R Switching example Features 0V X1 X3 S11 S12 S21 S22 SRB 101EXi -1A PA PA A1 A2 13 14 21 22 0V X1 X2 S11 S12 S21 S22 SRB 101EXi -1R PA PA A1 A2 13 14 21 22 Dimensions (H W D): 100 22.5 121 mm 1- or 2-selection control 1 safety enabling output Capable for signal processing of emergency stop control devices, interlocking devices etc. 1 additional auxiliary contact (signalling outputs may not be used in safety circuits Trailing edge (version -1R) Automatic reset function (version -1A) Optional cross-short monitoring (with a switch) Current and voltage restrictions of the input (intrinsically safe) Green LED displays for relays,, UB, and Top hat rail mounting DIN EN 60 715:2001 Housing of thermoplastic material acc. UL-94-V-0, graphite-black RAL 9011 Certified acc. DIN EN ISO 13 849-1:2007 Certified acc. ATEX 94/9/EG A1 A2 F1 F2 PA PA J S 0V S12 S22 X1 X3 SRB Ex i: installation in zone 2 Sensors: installation in zone 1/21 Logic 13 14 22 N 21 L1 +24 VDC Control Information on the circuit example: 2-selection control, shown by way of example of a guard monitoring systen with two limit switches, at least one of which is a contact with positive opening; with external reset button J. Power level: 2-channel selection, suitable for contact amplification and contact multiplication through contactors or relays with positively driven contacts. S = feedback circuit Wire breaks and cross-shorts (in switch position ) and earth leakages in the monitoring circuits are detected. The safety function is defined as follows: the enabling output 13-14 is open, when the input(s) S11-S12 and/or S21-S22 opens. The safety-relevant current path with the output contact 13-14 comply, in consideration with a B10d-value view, the following requirements (refer also Information within the meaning of DIN EN ISO 13 849-1 ): category 4 PL e acc. DIN EN ISO 13 849-1:2007 is equivalent to SIL 3 acc. DIN EN 61 508-2:2002 is equivalent SILCL 3 acc. DIN EN 62 061:2005 (is equivalent control category 4 acc. DIN EN 954-1:1997). For designation of the performance level (PL) acc. DIN EN ISO 13 849-1:2007 of the whole safety function (e.g. sensor, logic, actor), a view to all relevant components is necessary. 4

PROTECT SRB 200EXi-1A,...-1R for emergency stop- and guard monitoring SRB 200EXi-1A/-1R Switching example 0V X1 X3 S11 S12 S21 S22 SRB 200EXi -1A PA PA A1 A2 13 14 23 24 0V X1 X2 S11 S12 S21 S22 SRB 200EXi -1R PA PA A1 A2 13 14 23 24 Features 1- or 2-selection control 2 safety enabling outputs Capable for signal processing of emergency stop control devices, interlocking devices etc. Trailing edge (version -1R) Automatic reset function (version -1A) Optional cross-short rmonitoring (with a switch) Current and voltage restrictions of the input (intrinsically safe) Green LED displays for relays,, UB, A1 F1 F2 J S 0V S12 S22 X1 X3 Logic 13 23 L1 +24 VDC Dimensions (H W D): 100 22.5 121 mm and Top hat rail mounting DIN EN 60 715:2001 Housing of thermoplastic material acc. UL-94-V-0, graphite-black RAL 9011 Certified acc. DIN EN ISO 13 849-1: 2007 Certified acc. ATEX 94/9/EG A2 PA PA SRB Ex i: installation in zone 2 Sensors: installation up to zone 1/21 14 24 N Control Information on the circuit example: 2-selection control, shown by way of example of a guard monitoring systen with two limit switches, at least one of which is a contact with positive opening; with external reset button J. Power level: 2-channel selection, suitable for contact amplification and contact multiplication through contactors or relays with positively driven contacts. S = feedback circuit Wire breaks and cross-shorts (in switch position ) and earth leakages in the monitoring circuits are detected. The safety function is defined as follows: the enabling outputs 13-14/23-24 are open, when the input(s) S11-S12 and/or S21-S22 opens. The safety-relevant current path with the output contacts 13-14/23-24 comply, in consideration with a B10d-value view, the following requirements (refer also Information within the meaning of DIN EN ISO 13 849-1 ): category 4 PL e acc. DIN EN ISO 13 849-1:2007 is equivalent to SIL 3 acc. DIN EN 61 508-2:2002 is equivalent SILCL 3 acc. DIN EN 62 061:2005 (is equivalent control category 4 acc. DIN EN 954-1:1997). For designation of the performance level (PL) acc. DIN EN ISO 13 849-1:2007 of the whole safety function (e.g. sensor, logic, actor), a view to all relevant components is necessary. Information within the meaning of DIN EN ISO 13 849-1:2007 B 10d value (for one channel) With low load: 20.000.000 With maximum load: 400.000 CCF Conversion in MTTF d : refer to DIN EN ISO 13 849-1:2007 Annex C Item 4.2 B 10d MTTF d = n op = d op h op 3,600 s/h 0.1 n op t cycle > 65 points d op = average number of operating days per year h op = average number of operating hours per day t cycle = average request of the safety function in s (for example 4 per hour = 1 per 15 min = 900 s) 5

PROTECT SRB xxxexi-1x Technical data General tecnical data SRB 101EXi-1A, SRB 101EXi-1R, SRB 200EXi-1A, SRB 200EXi-1R Operating voltage 24 VDC 15%/+20%, residual ripple max. 10% Fuse of the operating voltage Power consumption Switching capacity of the enabling contacts internal fuse F1: T 50 ma/250 V internal fuse F2: T 100 ma/250 V max. 3.0 W 230 V; 3 A ohmic (inductive with suitable protective circuit) AC-15: 230 VAC/3 A DC-13: 24 VDC/3 A 3.15 A slow-blowing min. 10 V/10 ma max. 100 mω in new state Fuse of the enabling contacts Min. switching capacity Contact resistance Utilisation categories AC-15/DC-13: EN IEC 60947-5-1:2007 Contact materials/contacts AgSnO, self-cleaning, positively-driven Switching capacity of the auxiliary 24 VDC, 2 A contacts (21-22) Fuse of the auxiliary contacts Current and voltage at S11-S12, S21-S22 Current limiting an S11-S12, S21-S22 On-delay Drop-out delay Jumper in the case of voltage drop Air clearance and creepage distance 2 A slow-blowing 24 VDC, 5 ma 15 ma approx. 300 ms (version -1A) approx. 20 ms (version -1R) at emergency stop: approx. 20 ms at power failure: approx. 20 ms approx. 15 ms EN IEC 60664-1:2003 (DIN VDE 0110-1), 4 kv/2 EN 60 079-11:2007 (VDE 0170/0171 Part 7) Class of protection housing: IP 40 terminals: IP 20 installation space: IP 54 Cable connections Single core: rigid or flexible (with and without wire-end ferrule) 0.25 2.5 mm 2 Dual wire with same cross section: rigid or flexible (with wire-end ferrule without plastics) 0.25 2.5 mm 2 ; flexible (without or with TWIN wire-end ferrule) 0.5 1.5 mm 2 Tightening torque 0.6 Nm Max. resistance of entire line 30 Ohm Cable lengths (at nominal load) 1-channeled without cross-short recognition: 1.5 mm 2 = 1,500 m; 2.5 mm 2 = 2,500 m 2-channeled with/without cross-short recognition: 1.5 mm 2 = 1,500 m; 2.5 mm 2 = 2,500 m Ambient operating temperature 25 C... +60 C Storage temperature 40 C... +85 C Mechanical life 10 7 switching cycles EMC EN IEC 61 000-6-2:2005 Oscillations EN IEC 60068-2-6:1996: frequency: 10 55 Hz amplitude: 0.35 mm Climatic demands EN 60 068-2-3:1986 CE conformity acc. directives: Machine safety 98/37/EG EMC: 2004/108/EG ATEX: 94/9/EG Ex-relevant technical data refer to page 3 6

PROTECT SRB xxxexi-1x Switching examples S11 S12 Single-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and DIN EN 60 947-5-5:2005 Category 2 PL d acc. DIN EN ISO Dual-channel guard monitoring circuit with interlocking devices acc. EN 1088:2007 At least one positively opening contact. are not detected. Category 4 PL e acc. DIN EN ISO Dual-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and DIN EN 60 947-5-5:2005 are not detected. Category 4 PL e acc. DIN EN ISO 13 849-1:2007 reachable (with protected cable laying). Dual-channel guard monitoring circuit with interlocking devices acc. EN 1088:2007 At least one positively opening contact. are detected. Category 4 PL e acc. DIN EN ISO Dual-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and DIN EN 60 947-5-5:2005 are detected. Category 4 PL e acc. DIN EN ISO Dual-channel control with electromagnetic safety switches acc. DIN EN 60 947-5-3:2005 are not detected. Category 3 PL e acc. DIN EN ISO S11 S12 Single-channel guard monitoring circuit with interlocking devices acc. EN 1088:2007 At least one positively opening contact. Category 2 PL d acc. DIN EN ISO Dual-channel control with electromagnetic safety switches acc. DIN EN 60 947-5-3:2005 are detected. Category 3 PL e acc. DIN EN ISO 7

Elan Schaltelemente GmbH & Co. KG Im Ostpark 2 D-35435 Wettenberg Postfach 1109 D-35429 Wettenberg Telephone +49 (0)641 9848-0 Facsimile +49 (0)641 9848-420 E-Mail info@elan.schmersal.de Internet www.elan.de K.A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D-42279 Wuppertal Postfach 24 02 63 D-42232 Wuppertal Telephone +49 (0)202 6474-0 Facsimile +49 (0)202 6474-100 E-Mail info@schmersal.com Internet www.schmersal.com 04/08 W