Variable Axial Piston Pump A10V Series - 52/53

Similar documents
ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P.

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial Piston Variable Pump A10VO

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Axial Piston Variable Pump A10VSO

Axial piston variable pump A10V(S)O Series 31

Axial Piston Variable Pump A10VSNO

Axial piston variable pump A10VSO Series 31

Axial Piston Variable Pump A10VSNO

Axial Piston Variable Pump A10VO (US-Version)

Axial piston variable pump A10VO Series 32

Axial piston variable pump A10VO series 52 and 53. Americas. RE-A Edition: Replaces:

Axial Piston Variable Pump A10VSO

Axial piston fixed pump AA2FO

Axial piston variable pump A10VSO series 32

Axial piston variable pump A10VO series 52 and 53

Genuine Metaris MA10VO/VSO Technical Catalog. Variable Displacement Piston Pump - A10V Series 31 & 52

UŽSISAKYKITE internetu telefonu el. paštu

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A10VO

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump. A10VNO series 53. RE Edition: Replaces:

Axial piston variable pump A1VO series 10

Axial Piston Variable Pump A1VO Series 10

Axial Piston Variable Pump A18VLO Series 11

Axial piston variable pump. A10VNO series 53. Americas. RE-A Edition: Replaces:

Axial Piston Fixed Pump A2FO

Axial piston variable pump A10VO series 52 and 53

Axial Piston Variable Pump A18VLO

Axial piston variable pump A1VO Series 10

Axial Piston Fixed Pump A17FNO

2-Circuit Axial Piston Fixed Pump A18FDO

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

Axial piston variable pump A4VG Series 40

Axial piston variable pump A10VSO Series 31 for explosive areas ATEX II 3G ck IIB T4

Axial Piston Variable Pump KVAA

Axial piston fixed pump A17FO Series 10

Fixed Displacement Pump A2FO

Axial Piston Fixed Motor A10FM / A10FE (US-Version)

Axial piston variable pump A11V(L)O series 40

Axial Piston Variable Pump A4VTG

Axial piston fixed pump A17FNO Series 10

Axial piston variable pump A4VG Series 40

Axial piston variable pump A4VG Series 40

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial Piston Variable Pump A18VO Series 11

Axial Piston Variable Pump A4VTG

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump AA11VO

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version)

Variable Axial Piston Pump (A)A10VSO

Axial piston variable pump A11V(L)O Series 40

Axial Piston Variable Pump A7VO

Axial piston variable pump A4CSG Series 3x

Variable Displacement Pumps

Axial Piston Variable Pump AA10VG

Axial piston variable pump A18VO series 11

Axial Piston Variable Pump A17VO

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Axial Piston Variable Pump AA4VG

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Axial Piston Fixed Pump A17FNO Series 10

Axial piston variable double pump A28VLO Series 10

Fixed Displacement Motor A10FM A10FE

Fixed Displacement Motor AA2FM (A2FM)

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Axial Piston Variable Displacement Pump AA11VO

Axial piston variable pump A7VO

Axial piston fixed motor A2FM Series 70 A2FE Series 70

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial Piston Fixed Motor A2FM

VINCKE HYDRAULIC PUMPS

Axial piston variable pump (A)A4VSO

Variable Displacement Pump A4VG for closed circuits

Axial Piston Variable Pump A11VO

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx

AXIAL PISTON MOTORS SHMF

Variable Displacement Plug-In Motor A6VE

Axial Piston Variable Double Pump A8VO

Fixed Plug-In Motor A2FE

Fixed Plug-In Motor A2FE

Axial Piston Variable Pump (A)A4VSG (US-Version)

Variable Displacement Motor AA6VM (A6VM)

Axial piston variable pump A4VSO Series 10, 11 and 30 for HFC hydraulic fluids

Axial Piston Variable Pump A15VSO

Axial piston variable pump A4VSO for explosive areas ATEX II 3G c IIC T4

Axial Piston Variable Motor A6VM

Fixed displacement radial piston pump

Series 20 Axial Piston Pumps. Technical Information

Axial Piston Variable Motor AA6VM (A6VM)

Hydraulic Pumps T7 for variable speed drives

Axial Piston Variable Pump A4VG

Fixed Displacement Motor A2FM

Axial Piston Variable Pump A15VSO

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM (US-Version)

Transcription:

Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3 /rev-3.8in 3 /rev) Control Options - Pressure, Pressure & Flow, and Power eries 52 w w w. F l u i D y n e F P. c o m E m a i l : sales @ F l u i D y n e F P. c o m

Features: Variable Displacement Pump A10V, eries 52/53 Axial piston pump A10V in swashplate design is used for hydrostatic transmission in open loop circuits. Flow is proportional to drive speed and displacement. y adjusting the position of the swashplate it is possible to smoothly vary the flow. wash plate Cylinder block Variable piston Piston DFR Control valve Housing End cover haft A10V - 52/53 Valve plate - Flange/Threaded connections AE-UNC or metric - 2 to 3 drain ports - High permissible speeds - Good suction characteristics - ow noise level - High power/weight ratio - ong service life - hort control times - Axial and radial loading of drive shaft possible - Wide range of controls - Through drive option for multi-circuit system

Variable Displacement Pump A10V, eries 52/53 Technical Data: 1. Absolute Pressure at Port (A) P sabs min...11 psi (0.8 bar) P sabs max...75 psi (5 bar) 2. Output Operating Pressure Range Pressure at port Nominal pressure P N...3600 psi (250 bar) Peak pressure P max...4600 psi (315 bar) Minimum pressure P min... 145 psi (10 bar) 3. Case Drain Pressure Maximum pressure of leakage fluid (at ports, 1 and 2) 7 psi (0.5 bar) higher than input pressure at port, but not higher than 30 psi (2 bar) absolute. 4. Direction of Flow ( to ) 5. Table of Values (theoretical values, without considering mh and v : values rounded) ize 10 45 60 63 Displacement Vg max cm 3 /rev (in 3 /rev) 10.5 (0.61) 45 (2.75) 60 (3.66) 63 (3.84) Max. peed Nnom max rpm 3600 2600 2600 2600 Flow @1800 rpm QvE 1800 PM (gpm) 18 (4.8) 81.6 (21.6) 108 (28.8) 114 (30) Max. Flow Q v nom max /min (gpm) 37 (9.7) 117 (31) 156 (41) 163 (43) Max. Power Po max kw (HP) 35 (47) 49 (65) 65 (88) 68 (90) Max. Torque Tmax Nm (lb-ft) 42 (31) 179 (132) 238 (175.5) 250 (184) Rotary tiffness, Drive haft R U W Q K /P /C Nm/rad (lb-ft/rad) Nm/rad (lb-ft/rad) Nm/rad (lb-ft/rad) Nm/rad (lb-ft/rad) Nm/rad (lb-ft/rad) Nm/rad (lb-ft/rad) 9200 (6760) 6800 (5020) 10800 (7965) 37500 (27656) 41000 (30240) 30000 (22130) 34400 (25370) 43900 (32380) 65500 (48100) 69400 (51200) 49200 (36290) 54000 (39830) 34400 (25370) 73900 (54506) 65500 (48100) 69400 (51200) 49200 (36290) 54000 (39830) 34400 (25370) 73900 (54506) Weight (without fluid) M kg (lbs) 8 (17) 18(40) 22 (48.5) 22 (48.5) Note: Values shown are valid for an absolute pressure of 1 bar at suction port.

Variable Displacement Pump A10V, eries 52/53 Technical Data: If the flow is reduced or if the inlet pressure is increased the speed may be increased according to the diagram. peed n/n 0 max [rpm] 1.2 1.1 1.0 peed vs. Inlet Pressure 23 20 17.5 14.5 13 (1.6) (1.4) (1.2) (1.0) (0.9) Inlet pressure p abs [psi (bar)] 0.9 0.7 0.8 0.9 Displacement V g /V g max [in 3 (cm 3 )] 1.0 11.5 (0.8) 6. Determination of ize V g n η v ( V g n η v ) Flow q v = [gpm] q v = [/min] 231 1000 V g p ( V g ) p Torque T = [lb-ft] T = [Nm] 24 π η mh 20 π η mh q v ( q v ) p p Power P = [HP] P = [kw] 1714 η t 600 η t V g = Displacement per revolution in in p = Differential pressure in psi (bar) n = peed in rpm (min 1 ) η v = Volumetric efficiency η mh = Mechanical-hydraulic efficiency η t = Total efficiency Fluid MR20 (Q/TCNK12-2001) IO 32 IO 46 IO 68

Variable Displacement Pump A10V, eries 52/53 Technical Data: Operating Viscosity Range V opt = 16 mm 2 /s~36 mm 2 /s (80 to 170 U) For optimum efficiency and service life we recommend that the operating viscosity (at operating temperature) be selected in the range: V opt = optimum operating viscosity 16mm 2 /s~36 mm 2 /s referred to tank temperature (open loop circuit). imits of Viscosity Range (The following values are valid for extreme operating conditions) V min = 10 mm 2 /s for short periods at max. leakage oil temperature of 80 0 C (176 0 F) V max = 1000 mm 2 /s Temperature Range t min = -20 0 C (-4 0 F) ; t max = +80 0 C (176 0 F) Filtration In order to ensure reliable operation of the axial piston unit, the operating fluid must be maintained to a cleanliness class of at least: 16/19 to I04406. This may be achieved with filter elements, cleanliness class of 10µm. Installation Notes Viscosity 7400 4600 3000 2000 1000 500 300 200 100 80-40 -4 32 68 104 140 176 212 F -40-20 0 20 40 60 80 100 C 1600 1600 1000 600 400 200 100 60 40 20 60 10 U mm 2 /s mm 2 /s U 42 5 5 42-40 -25 10 0 10 30 50 70 90 115 C t min = -40 F (-40 C) VG 68 VG 46 VG 32 VG 22 VG 100-40 -13 14 32 50 86 122 158 194 240 F Temperature t Fluid Temperature Range 7400 36 170 16 80 t max = 240 F (115 C) The pump housing must be filled with fluid during commissioning and remain full when operating. The concentricity between engine transmission shaft and pump shaft must less than 0.05mm.

Technical Data: Variable Displacement Pump A10V, eries 52/53 Drive Power and Flow Operating material: Hydraulic fluid IO VG 46 DIN 51519, t = 50 C ize 45 n = 1500 rpm Flow q v n = 2600 rpm gpm (/min) 30 (120) 25 (100) 20 (80) 15 (60) 10 5 0 (40) (20) 0 (50) q v (100) ize 10 n = 1500 rpm n = 3600 rpm Flow q V gpm 10 7.5 5 2.5 (150) (/min) (35) (25) (15 ) (5) 0 (200) q V (50) P qv max P qv min 1000 2000 3000 Operating pressure p (100) (150) p qv min (200) p qv max (250) 1000 2000 3000 3625 Operating presure p 0 (250) (bar) 3625 ( kw ) HP (60) 80 (50) (40) (30) (20) (10) psi 60 40 20 Drive power Pqv ize 60/63 n = 1500 rpm n = 2600 rpm Flow q v gpm 40 35 30 25 20 15 10 5 0 (/min) (160) (140) (120) (100) (80) (60) (40) (20) 0 (50) q v (100) (150) (kw) HP 30 (20) 25 (15 ) 20 (10 ) 15 10 (5) 5 0 (bar) psi (200) P qv max P qv min 1000 2000 3000 Operating pressure p Drive power P q V ( kw ) HP (80) 100 (70) (60) 80 (50) (40) (30) (20) (10) 0 (250) (bar) 3625 psi 60 40 20 Drive power P qv

Variable Displacement Pump A10V, eries 52/53 Ordering Code: ize A10V 45 DR 52 P Displacement 10 45 60 1) 63 2) cm 3 /rev (in 3 /rev) Control Devices Pressure control Pressure remote control Pressure & Flow Power Control w/ pressure cut-off Power control w/ pressure cut-off Power w/remote pressure Power w/flow (-T port blocked) 10.5 45 60 63 (0.61) (2.75) (3.66) (3.84) DR DRG (-T port open) DFR, DRF 2) (-T port blocked) DFR1, DR 2) tart of control A5D - 10 to 35 bar (145-507 psi) A6D - 36 to 70 bar (522-1015 psi) A7D - 71 to 105 bar (1030-1523 psi) A8D - 16 to 140 bar (1537-2031 psi) A9D - 141 to 230 bar (2045-3336 psi) A()D 2) A()DG 2) A()D 2) eries 10 45 60 63 eries 52 53 Direction of Rotation Viewed from shaft end Clockwise Counter-clockwise R eals una-n (NR per DIN IO 1629) FPM (Flurocarbon/Viton) P V haft End 10 45 60 63 Keyed 3/4 1 1 1/4 1 1/4" K plined 3/4"-11T 1"-15T 1 1/4"-14T 1 1/4"-14T Full plined -Reinforced "" 1"-15T 1 1/4"-14T 1 1/4" -14T R plined "ow Torque" 5/8"-9T 7/8"-13T 1"-15T 1"-15T U Full plined -Reinforced "U" 7/8"-13T 1"-15T 1"-15T W Full plined AE- 7/8"-13T 7/8"-13T Q Metric Keyed 18mm P

Variable Displacement Pump A10V, eries 52/53 C 62 N00 097 pecial uffix Omit if none required Max volume stop adjust (std) 097 Thru Drives 10 45 60 63 Non-Thru Drive (without thru drive) N00 With Thru Drive to mount pump on back (side ports only) Mtg Flg Hub To Mount 82-2 (A) 5/8"-9T (A) A10V18(U,W), 10(U) K01 82-2 (A) 3/4"-11T (A) A10V18(,R), 10() K52 101-2 () 7/8"-13T () A10V28(,R), 45(U,W) K68/K02 101-2 () 1"-15T (-) A10V45(,R), 60/63C(U,W) K04 127-2 (C) 1 1/4"-14T (C) A10V71(,R), 100(U,W) K07 127-4 (C) 1 1/4"-14T (C) A10V60/63D(,R) K15 K** ervice Ports 10 45 60 63 4-olt Flange Ports tr. Thread O-Ring Ports Rear Ports, Metric Thread 11 Rear Ports, UNC Thread 61 ide Ports, Metric Thread 12 ide Ports, UNC Thread 62 Rear Ports, Threaded Metric 14 Rear Ports, Threaded UNC 64 Mounting Flange Pilot Diameter (in/mm) 10 45 60 63 AE 2-olt AE-A (3.25"/82.5) AE- (4.0"/101.6) AE- (4.0"/101.6) AE- (4.0"/101.6) C IO 2-olt Metric 80 mm 100 mm A AE 4-olt AE-C (5.0"/127) AE-C (5.0"/127) D = Available = Not available Note: 1) eries 52 units are delivered as standard with 60 cm 3 /rev. Higher values on request. 2) Control DRF, DR, and A()D(): Available with size 18, and 63, only in 53 series.

Variable Displacement Pump A10V, eries 52/53 Pressure Control DR : The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure may be smoothly set at the pilot valve. 1 2 (avail. 53-design only) tatic Characteristic (at n 1 = 1500 rpm; t fluid = 120 F (50 C)) psi (bar) 3600 (250) Operating pressure p etting range 1) 290 (20) Flow q v [gal (l/min)] Hysteresis / pressure rise pmax Ports Pressure port uction port, 1,2 Case drain ports ( 1,2 sealed) Control Data Hysteresis and repetitive accuracy p...max. 3 bar (44 psi) Max. Pressure Increase ize 10 45 60 63 P ar (psi) 6 (90) 6 (90) 8 (115) 8 (115) Pilot oil consumption...max. approx. 3 /min (0.8 gpm)

Variable Displacement Pump A10V, eries 52/53 Pressure Control, Remote Control DRG : Function and design as for DR. Not included in the delivery contents A pressure relief valve may be externally piped to port for remote control purposes. It is not, however, included with the DRG control. The differential pressure at the pilot valve is set as standard to 20 bar (290 psi) and this results in a pilot flow of 1.5 /min (0.40 gpm). If another setting is required (in the range of 10-22 bar) (145-319 psi), please state this in clear text. 1 tatic Characteristic (at n 1 = 1500 rpm; t fluid = 120 F (50 C)) Operating pressure p psi 3600 etting range 1) 290 (bar) (250) (20) Flow q v [gpm (l/min)] Hysteresis / pressure rise pmax Ports 2 (avail. 53- design only) Pressure port uction port, 1,2 Case drain ports ( sealed) 1,2 Pilot pressure port Control Data Hysteresis and repetitive accuracy P... max. 3 bar (44 psi) Max. Pressure Increase ize 10 45 60 63 P ar (psi) 6 (90) 6 (90) 8 (115) 8 (115) Pilot oil consumption...max. approx. 4.5 /min (1.19 gpm)

Variable Displacement Pump A10V, eries 52/53 Pressure/Flow Control, oad ensing: DFR/DRF -T port open, DFR1/DR -T port blocked In addition to the pressure control function, the pump flow may be varied by means of a differential pressure at the actuator (e.g. an orifice). In model DFR1/DR the orifice is plugged. 1 tatic Characteristic Flow control at n 1 = 1500 rpm; t fluid = 120 F (50 C)) Plugged in DR (DFR1) valve Not included in the delivery contents Operating pressure p psi (bar) 3625 (250) etting range 1) 290 (20) Flow q v [gpm (l/min)] Hysteresis / pressure rise pmax 2 (avail. -53 design only) Ports Pressure port uction port, 1, 2 Case drain ports ( 1,2 sealed) Pilot pressure port Flow control/differential pressure p: Adjustable between 14 and 22 bar (200-320 psi) (higher values on request). tandard setting: 21 bar (300 psi). If a different setting is required, please state in clear text. When port is unloaded to tank, a zero stroke pressure of p = 21 bar (300 psi) ( stand by ) results. tatic characteristic at variable speed Flow qv [l/min] peed n [rpm] Hysteresis / pressure rise pmax Control Data For pressure control technical data see DR Pressure control. Max. flow deviation (hysteresis and increase) measured at drive speed n = 1450 rpm ize 10 45 60/63 ΔQ max /min (gpm) 1.5 (0.5) 1.8 (0.48) 2.5 (0.66) Pilot oil consumption DFR/DRF...max. approx. 3-4.5 /min (0.8-1.19 gpm) Pilot oil consumption DFR1/DR...max. approx. 3 /min (0.8 gpm)

Pressure, Flow, and Power Control A()D.. : Pressure control equipped as DR(G), see page 11. Flow control equipped as DRF, DR, see page 12. Variable Displacement Pump A10V, eries 52/53 In order to achieve a constant drive torque with varying operating pressures, the cradle and with it the output flow from the axial piston pump is varied so that the product of the flow and pressure remains constant. Flow control is possible below the power control curve. When ordering, the power setting requirements must be given: (ie: 27 HP(20kW) @ 1500 rpm, and 3,045 psi (210 bar) max system pressure). tart of Control psi (bar) Torque T [ lb-ft (Nm) ] 45 63 Order Code 145-510 (10-35) 7.4-22.1 (10-30) 11-32 (15-43) A5 520-1015 (36-70) 22.2-43.5 (30.1-59) 32-61 (43.1-83) A6 1030-1520 (71-105) 43.6-62 (59.5-84) 61-88 (83.1-119) A7 1535-2030 (106-140) 62-83 (59.1-84) 88-116 (119-157) A8 2045-3335 (141-230) 83-139 (112.1-189) 116-195 (157.-264) A9 Circuit diagram (AD) tatic Curves and Torque Characteristic Operating pressure p p si (bar) 4350 (300) 3620 2900 2175 1450 725 (250) (200) (150) (100) (50) A9 A8 A7 A6 Circuit diagram (ADG) with pressure cut-o ly operated Not included in the delivery contents 0 (0) A5 0 100 q V (see table above) Circuit diagram (AD) Torque T [lb-ft (Nm)] A9 A8 A7 A6 A5 0 100 V v [%] 1 Not included in the delivery contents 2

(ø DIA 82.55 3.248 3.250 ) - 0 0.054 2 1. 1 2.20 (53.5) (56 ) DIA (ø 11) 0.43 Variable Displacement Pump A10V, eries 52/53 A10V10 Dimensions: DR - Hydraulic Pressure Controller Clockwise Rotation 0.43 (11) 0.25 (6.4) Flange IO3019-1 2.87 (73) 45 2.20 (5 6) max. 4.33 ( 110) 0.35 (9 ) Y 45 1 0.94 (24) 5.83 (14 8) 7.09 (18 0) 4.19 (10 6.4) 5.28 (134) View Y Clockwise Rotation View Y Counter-Clockwise Rotation 1.13 1.13 (28.6) (28.6) 1.13 1.13 (28.6) (28.6) 2.00 (51) 2.00 (51) 2.00 (51) 2.00 (51)

- 0 0.04 80 Variable Displacement Pump A10V, eries 52/53 A10V10 Dimensions: DRG / DFR / DFR1 - Hydraulic Controller Clockwise Rotation max. 4.33 (110) 5.75 (146) 1.57 (40) 3.74 (95) 4.02(102) 1 7.05 (179) Metric Mounting Flange and haft P - Parallel Keyed haft 20.5mm diameter DIN 6885 A6x6x25 key 6.4 Flange IO 3019-2 ø 6 11 20.5-0.1 + 0.009 ø18-0.004 2 25 + 0.3 28 0 ø22 24 Centering R3 15 x 6.7 DIN 332 36

Variable Displacement Pump A10V, eries 52/53 A10V10 Dimensions: Drive hafts and Port Dimensions DIA 0.750 0.749 K - Parallel Keyed haft 3/4 diameter; 3/16 sq. key IO 3019-1 19-1 0.01(2.5) 1.13 (28.6) (ø19.05-0.02 ) Centering 4) R 0.12x0.26 DIN 332 1.30 (33) 0.31 (8) 1.61(41) +0.05 21.1-0.1 0.833 0.827 0.188 +0.025 0.187 (4.76 ) - plined haft 3/4 diameter; 11T 16/32 DP 1) AE J744 1/4-20UNC-2 1.18 (3 0) 0.35 (14) 0.19 (5 ) 0.87 (21) 1.50 (3 8) U - plined haft 5/8 diameter; 9T 16/32 DP 1) AE J744 0.94 (23. 8) Centering 4) R12 x 0.26 DIN 332 0.62 (15. 8) 1.25 (3 1.8) Ports Outlet Port, Rear Threaded Inlet Port, Rear Threaded Outlet Port, Rear Threaded Inlet Port, Rear Threaded Port Code tandard ize Max Tightening Torque 64 IO 11926 14 IO 11926 DIN 3852 1-1/16-12 UNF-2; 0.79"(20) deep 1-1/16-12 UNF-2; 0.79"(20) deep M27x2; 0.63" (16) deep M27x2; 0.63" (16) deep 243 lb-ft (330 Nm) 243 lb-ft (330 Nm), 1 Case Drain Ports ( 1 plugged) 64/14 IO 11926 9/16-18UNF-2; 0.43" (11) deep 59 lb-ft (80 Nm) Pilot Pressure Port 64/14 IO 11926 7/16-20UNF-2; 0.45 (11.5) deep 29 lb-ft (40 Nm)

DIA 1.50 ø38 DIA 0.98 (ø25) Variable Displacement Pump A10V, eries 52/53 A10V45 Dimensions: DR - Hydraulic Pressure Controller Clockwise Rotation 2), -52 eries Port plate 61/11 0.37 (9.5) 0.25 (6.3) 3.90 (99 ) 0.47 (12 ) 1.18 (3 0) 45 Flange IO 3019-1 DIA 4.000 ( Ø101.6 ) 1 5.18 (131.5) 3.07 (7 8) 0.56 (14.3) 3.03 (77) 2.70 (68.5) 7.44 (18 9) max. 8.68 (220.5) 5.75 (146) 6.77 (172 ) View Port plate 64 2.75 (69.9 ) 2.06 (52.4) 1.41 (35.7) 30 1.03 (26.2) 1.50 (3 8) 30 1.50 (3 8) 1.50 (38) 1.50 (38) 1) Primary dimensions for pump apply for series -52 and -53 as seen above. 2) ocation of service ports and are turned 180 for counter-clockwise rotation.

Variable Displacement Pump A10V, eries 52/53 A10V45 Dimensions: DR - Hydraulic Pressure Controller Clockwise Rotation 2), -52 eries Port plate 62/12 Detail Z 0.37 (9.5) 0.25 (6.3) max. 8.68 (220.5) 5.93 (150.5) 3.90 (9 9) 0.47 (12) 1.18 (3 0) 2.06 (52.4) DIA 0.98 (Ø25) 1.03 (26.2) View Y Flange IO 3019-1 DIA 4.000 ( Ø101.6 ) 1 DIA 1.50 (ø38) 69.9 Y Z 7.01 (178 ) 8.31 (2 11) 1.41 (35.7) 3.54 (9 0) 3.54 (9 0)

Variable Displacement Pump A10V, eries 52/53 A10V45 Dimensions: DRG / DFR / DFR1 1) 3) - Hydraulic Controller Remote Pressure Control/ Pressure and Flow Clockwise Rotation 2), -52 eries max. 8.68 (220.5) 5.93 (150.5) 2.68 (68) 1 5.18 (131.5) 4.53 (115) A( )D(/G) 1) 4) - Hydraulic Controller Pressure, Flow and Power Control Clockwise Rotation 2), -53 eries 9.25 (235) 5.75 (146) 5.24 (133) 4.57 (116.4) 2.68 (68) 1 2 1) Primary dimensions for pump apply for series -52 and -53 as seen on page 18. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. 3) DFR1; Pressure and flow control with blocked bleed down orifice 4) Only for -53 series.

Variable Displacement Pump A10V, eries 52/53 A10V45 Dimensions: Drive hafts and Port Dimensions K - Parallel Keyed haft 1.0 diameter; 1/4 sq. key IO 3019-1 25-1 - plined haft 1.0" major dia.15t 16/32 DP AE J744-25-4 (-) 1.11 DIA 1.00 (28.2) (ø25.4 ) 0.09 1.50 (38.1) (2.2) 1.37 (34. 9) 1/4-20UNC-2 0.63 (16 ) DIA 0.98 (ø25) 0.250 (6.35) 1/4-20UNC-2 1.49 (38) 0.63 (16) 0.20 (5) 1.18 (3 0) 1.81 (46) 1.81 (45. 9) R - plined haft 1.0" major dia.15t 16/32 DP AE J744-25-4 (-) 1/4-20UNC-2 Usable shaft length 0.63 (16 ) 0.20 (5 ) 1.16 (29.5) 1.81 (45.9) U - plined haft 7/8" major dia.13t 16/32 DP AE J744-22-4 () 1/4-20UNC-2 1.30 (33.1) 0.63 (16) 0.20 (5 ) 0.99 (25.1) 1.61 (41) W - plined haft 7/8" major dia.13t 16/32 DP AE J744-22-4 () 1/4-20UNC-2 Usable shaft length 0.63 (16 ) 0.20 (5) 0.98 (25) 1.61 (41) Ports Outlet Port, AE Flange (code 61) Inlet Port, AE Flange Outlet Port, AE Flange (code 61) Inlet Port, AE Flange Outlet Port; Threaded Inlet Port; Threaded Port Code 61/62 tandard AE J518; IO 68 11/12 AE J5183) ; DIN 13 64 IO 11926 ize 1.0"; 3/8-16UNC-2; 0.75 (19) deep 1-1/2"; 1/2-13 UNC-2; 0.87 (22) deep 1.0"; M10 x 1.5; 17 deep 1-1/2"; M12 x 1.75; 20 deep 1-5/16"-12UN-2; 0.79 (20) deep 1-7/8-12UN-2; 0.79 (20) deep Max Tightening Torque 31 lb-ft (42 Nm) 48 lb-ft (66 Nm) 243 lb-ft (330 Nm), 1, 4) Case Drain Ports ( 1 plugged) All IO 11926 3/4-16UNF-2 116 lb-ft (160 Nm) 2 Pilot Pressure Port All IO 11926 7/16-20UNF-2; 0.45 (11.5) deep 29 lb-ft (40 Nm) 1) Primary dimensions for pump apply for series -52 and -53 as seen above. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. 3) Metric fixing thread is a deviation from standard. 4) Only for -53 series.

A10V60/63 1) Dimensions: DR - Hydraulic Pressure Controller Mounting Flange C, Clockwise Rotation 2), -52 eries A10V (60/63)DR/52R-PC61N00 Port plate 2) 61/11 Variable Displacement Pump A10V, eries 52/53 Flange IO 3019-1 DIA 4.00 (Ø101.6) 0.37 (9.5) 1.57 (4.0) max. 8.68 (220.5) 4.61 (117 ) 5.39 (137) 1 45 78.5 0.56 (14.3) 3.42 (87) 2.99 (78) 0.59 (15 ) 8.19 (208) 5.75 (146) 6.77 (172 ) View Port plate 2) 64 View 3.06 (77.8) DIA 1.97 (Ø50) 0.98 (Ø25) 2.06 (52.4) 1.67 (42.9) 1.03 (26.2) 1.30 (33) 1.81 (46) 2-1/2-12UN-2 1.30 (33) 1.81 (46) 1-5/16-12UN-2 1) Primary dimensions for pump apply for series -52 and -53 as seen above. 2) ocation of service ports and are turned 180 for counter-clockwise rotation.

Variable Displacement Pump A10V, eries 52/53 A10V60/63 1) Dimensions: DR - Hydraulic Pressure Controller Mounting Flange C, Clockwise Rotation 2), -52 eries A10V (60/63)DR/52R-PCxxN00 Port plate 2) 62/12 Flange IO 3019-1 0.50 (12.7) 1.57 (40) max. 8.68 (220.5) 4.61 (117 ) View Y DIA 4.00 (Ø101.6 ) DIA 1.97 (Ø50) 3.06 (77.8) Y Z 0.59 (15 ) 7.93 (201.5) 9.43 (239.5) 1.67 (42.9) Mounting Flange D 1), Clockwise Rotation 2), -52 eries A10V (60/63)DR/52R-PDxxN00 2.06 (52.4) 0.98 (Ø25) 1.11 (26.2) 2.83 (72) 2.83 (72) A10V60/63- D Mounting Flange View Y Flange IO 3019-1 0.50 (12.7) 1.57 (40) max. 8.68 (220.5) 4.61 (117 ) 2.83 (72) 2.83 (72) Z DIA 5.00 (Ø127 ) 0.59 (15 ) 7.93 (201.5) 9.43 (239.5) 1.67 (42.9) DIA 1.97 (Ø50) 3.06 (77.8) Y 5.41 (137.4) 5.83 (148) 1 45 3.09 (78.5) 14.3 114.5 3.07 (78) 3.43 (87) 1) Primary dimensions for pump apply for series -52 and -53 as seen above. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. 4.51 (114.5) 5.75 (146)

A10V60/63 1) Dimensions: DR - Hydraulic Pressure Controller Mounting Flange D, Clockwise Rotation 2), -53 eries A10V (60/63)DR/53R-PDxxN00 Port plate 2) 61/11 0.50 (12.7) 0.25 (6.3) Flange IO 3019-1 DIA 5.00 (Ø127) 0.59 (15) 4.55 (115.5) 1.54 (39) 1 Variable Displacement Pump A10V, eries 52/53 max. 8.68 (220.5) 8.19 (208) View Z View Z 5.51 (140) 4.37 (111) 0.55 (14) 4.51 (114.5) 2 3.05 (77.5) 45 45 43 45 1 4.51 (114.5) 5.75 (146) 5.91 (150) View 3.11 (7 9) 5.75 (146) 3.46 (88) 3.50 (89) Mounting Flange D, Clockwise Rotation 2), -53 eries A10V (60/63)DR/53R-PDxxN00 Port plate 2) 62/12 max. 8.68 (220.5) 4.55 (115.5) 0.50 (12.7) 1.54 (39) 0.25 (6.3) 1 Flange IO 3019-1 2.06 (52.4) 0.98 2.06 (Ø25) (52.4) 0.98 (Ø25) 1.11 (26.2) 1.11 (26.2) DIA 1.97 (Ø50) 3.06 (77.8) 1.67 (42. 9) 1.30 (33) View Y 1.81 (46) DIA 0.98 (Ø25) 2.06 (52.4) 1.03 (26.2) DIA 5.00 (Ø127) 0.59 (15) 7.93 (20 1.5) 9.43 (239.5) 1.69 (42.9) DIA 1.97 (Ø50) 3.06 (77.8) 1) Primary dimensions for pump apply for series -52 and -53 as seen above. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. Y 2.83 (72) 2.83 (72) Z

Variable Displacement Pump A10V, eries 52/53 A10V60/63 1) Dimensions: DR - Hydraulic Pressure Controller Mounting Flange C, Clockwise Rotation 2), -53 eries A10V (60/63)DR/53R-PCxxN00 Port plate 2) 61/11 max. 8.68 (220.5) 4.55 (115.5) 1 Flange IO 3019-1 4.00 DIA (Ø 101.6 ) 1 8.19 (208.2) 5.53 (140.4) 4.37 (111) 2 3.05 (77.5) 45 43 5.75 (146) 6.77 (172 ) 3.11 (7 9) 14.3 3.50 (89) 3.46 (88) DRG / DFR / DFR1 3) - Hydraulic Controller 1) DRF 4) / DR 3) 4) A( )D(/G) 4) - Hydraulic Controller 1) Remote Pressure Control/ Pressure and Flow Clockwise Rotation 2), -52 eries Pressure, Flow and Power Control Clockwise Rotation 2), -53 eries max. 8.68 (220.5) 5.93 (150.5) 1 5.39 (137) 4.76 (121) 2.56 (65) 1 9.72 (247) 5.91 (15 0) 5.51 (140) 5.04 (128) 4.88 (124) 2.56 (65) 1 2 1) Primary dimensions for pump apply for series -52 and -53 as seen above and on previous pages. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. 3) DFR1/DR; Pressure and flow control with blocked bleed down orifice. 4) Only for -53 series.

A10V60/63 Dimensions: Drive hafts and Port Dimensions Variable Displacement Pump A10V, eries 52/53 K - Parallel Keyed haft 1.25 diameter; 5/16 sq. key IO 3019-1 32-1 (C) - plined haft 1.25" major dia.14t 12/24 DP 4) AE J744-32-4 (C) R - plined haft 1.25" major dia.14t 12/24 DP 4)5) AE J744-32-4 (C) 1.385 DIA 1.25 (35.3) (ø31.75) 0.12 (3) 5/16-18UNC-2 0.75 (19 ) 1.87 (47.5) 1.63 ( 41. 3) 2.18 (55.4) DIA 1.37 (ø34.91) 0.3125 (7.94) 5/16-18UNC-2 1.87 (47.5) 0.75 (19) 0.20 (5 ) 1.56 2.18 (55.4) 5/16-18UNC-2 Usable shaft length 0.75 (19 ) 0.20 (5) 1.50(38) 2.18 (55.4) U - plined haft 1.0" major dia.15t 16/32 DP 4) AE J744-25-4 (-) W - plined haft 1.0" major dia.15t 16/32 DP AE J744-25-4 (-) 4) 5) Q - Full plined haft 7/8" major dia.13t 16/32 DP 4)5) AE J744-22-4 () 1/4-20UNC-2 1.30 (33. 1) 0.63 (16) 0.20 (5 ) 0.98 (25) 1.81 (45. 9) 1/4-20UNC-2 Usable shaft length 0.63 (16 ) 0.20 (5) 1.14 (29) 1.81 (45.9) 1/4-20UNC-2 Usable shaft length 0.63 (16 ) 0.20 (5) 0.98 (25) 1.61 (41) Ports Outlet Port, AE Flange (code 61) Inlet Port, AE Flange Outlet Port, AE Flange (code 61) Inlet Port, AE Flange Outlet Port; Threaded Inlet Port; Threaded Port Code 61/62 tandard AE J518; IO 68 11/12 AE J5183) ; DIN 13 64 IO 11926 ize 1.0"; 3/8-16UNC-2; 0.75 (19) deep 2.0"; 1/2-13 UNC-2; 0.87 (22) deep 1.0"; M10 x 1.5; 17 deep 2.0"; M12 x 1.75; 20 deep 1-5/16"-12UN-2; 0.79 (20) deep 2-1/2"-12UN-2; 0.87 (22) deep Max Tightening Torque 31 lb-ft (42 Nm) 48 lb-ft (66 Nm) 243 lb-ft (330 Nm), 1, 4) Case Drain Ports ( 1 plugged) All IO 11926 7/8-14UNF-2; 0.51 (13) deep 116 lb-ft (160 Nm) 2 Pilot Pressure Port All IO 11926 7/16-20UNF-2; 0.45 (11.5) deep 29 lb-ft (40 Nm) 1) Primary dimensions for pump apply for series -52 and -53 as seen above and on previous pages. 2) ocation of service ports and are turned 180 for counter-clockwise rotation. 3) Metric fixing thread is a deviation from standard. 4) ANI 92.1a, 30 pressure angle, flat root, side fit, tolerance class 5. 5) plines according to ANI 92.1a, run out of spline is a deviation from standard.

Variable Displacement Pump A10V, eries 52/53 Through Drives: Permissible moment of inertia izes 10 45 60 63 m1 kg (lbs) 18 (8) 18 (40) 22 (49) 22 (49) 1 mm (ins) 95 (3.74 ) 100 (3.94 ) 100 (3.94 ) Axial piston unit A10V0 can be supplied with a through drive, as shown in the ordering code on pages 8 and 9. The type of through drive is determined by codes (K01-K15). If the combination pump is not mounted in the factory, the simple type code is sufficient. Order the coupling kit separately. Included in the kit are: Coupling sleeve, seals and bolts. Combination Pumps: y mounting combination pumps circuits independent of each other are available for use. 1. If the combination pump consists of two A10V pumps and if these are to be delivered ready assembled, then the two types codes are to be combined with a +. Ordering Example: A10V45DR/52R-PC62K04 + A10V45DFR/52R-PC62N00 2. If a gear pump or radial piston pump is to be mounted in the factory as a second pump. It contains a list of the various pump combinations together with the type code of the first pump.

Unit Dimensions of Combination Pumps: Variable Displacement Pump A10V, eries 52/53 A10V( )0 + A10V( )0 Pump 1 A10V/45 A10V/60 A10V/63 (Dimensions mm) A1 A2 A3 A4 A1 A2 A3 A4 A1 A2 A3 A4 Pump 2 A10V45 178 229 418 445 202 255 444 471 202 255 444 471 A10V60 - - - - 202 255 463 471 202 255 463 471 A10V63 - - - - 202 255 463 471 202 255 463 471 Dimensions of Through Drives: K01 Flange AE 82-2 (AE A, 2-hole) for mounting of external gear pump G2 or an A10V10, A10V18 - U haft. Order K01 coupling separately to mate to a 5/8 dia. 9T-tooth shaft. Omitted for NG28 A 3 A 2 45 A 4.19 (10 6.5) DIA 3.2520 3.2508 (ø82.55 +0.050 +0.020 ) A 4 Omitted for NG28 to mounting flange A 1 0.39 (10 ) izes A1 mm (in.) A2 mm (in.) A3 mm (in.) A4 45 234 (9.21 ) 10.7 (0.42 ) 53 (2.09 ) 6-M10-1.5, (16 deep) 60/63 255 (10.01 ) 9.5 (0.37 ) 59 (2.32 ) 6-M10-1.5, (16 deep)

Variable Displacement Pump A10V, eries 52/53 Dimensions of Through Drives (continued): K52 Flange AE 82-2 (AE A, 2-hole) for mounting of an A10V10, A10V18 - shaft or an A10V28 - U shaft. Order K01 coupling separately to mate to a 3/4 dia. 11T-tooth shaft. Omitted for NG28 A 4 A 3 45 A 4.19 10 6.5 DIA 3.2520 3.2508 +0.050 (ø82.55 +0.020 ) A 5 Omitted for NG28 to mounting flange A 2 A 1 0.39 (10 ) izes A1 mm (in.) A2 mm (in.) A3 mm (in.) A4 45 234 (9.21 ) 39.4 (1.55 ) 53 (2.09 ) 6-M10-1.5, (16 deep) 60/63 255 (10.01 ) 39.4 (1.55 ) 59 (2.32 ) 6-M10-1.5, (16 deep) K68 Flange AE 101-2 (AE, 2 hole) for mounting an A10V45 - U shaft or an A10V28 - shaft. Order K68 coupling separately to mate to a 7/8 dia. 13T-tooth shaft. Omitted for NG28, 45 A 4 A 3 45 A 5.75 (146) 4.0020 4.0008 (ø101.6 ) DIA +0.050 +0.020 A 5 Omitted for NG28, 45 to mounting flange A 2 A 1 0.39 (10 ) izes A1 mm (in.) A2 mm (in.) A3 mm (in.) A5 45 234 (9.21 ) 42.4 (1.67 ) 18 (0.71 ) 2-M12-1.75, (18 deep) 60/63 255 (10.04 ) 42.4 (1.67 ) 18 (0.71 ) 2-M12-1.75, (18 deep)

Dimensions of Through Drives (continued): Variable Displacement Pump A10V, eries 52/53 K04 Flange AE 101-2 (AE, 2 hole) for mounting an A10V45 - shaft or an A10V60/63 - U haft. Order K04 coupling separately to mate to a 1 dia. 15T-tooth shaft. Omitted for NG45 A 4 A 3 45 A 5.75 (146) DIA +0.050 +0.020 4.0020 4.0008 (ø101.6 ) A 5 A 2 A 1 0.39 (10 ) izes A1 mm (in.) A2 mm (in.) A3 mm (in.) A5 45 229 (9.02 ) 48 (1.88 ) 19 (0.74 ) 2-M12-1.75, (18 deep) 60/63 255 (10.04 ) 47.4 (1.87 ) 18.4 (0.72 ) 2-M12-1.75, (18 deep) K15 Flange AE 127-4 (AE C, 4 hole) for mounting an A10V60/63 D pilot pump with an -shaft. Order K15 coupling kit separately, for mating with a 1-1/4 dia.14ttooth spline shaft. A A 4 A 3 4.51 (114.5) 5.0020 5.0008 DIA +0.050 +0.020 (ø127 ) Omitted for NG45 to mounting flange 4.51 (114.5) A 5 0.53 to mounting flange (13.4) A 1 izes A1 mm (in.) A3 mm (in.) A4 mm (in.) A5 60/63 255 (10.04 ) 8 (0.31 ) 59 (2.32 ) 2-M12-1.75, (16 deep)

Variable Displacement Pump A10V, eries 52/53 Installation Instructions: General The axial piston unit must be filled with hydraulic fluid and air bled during commissioning and operation. This must also be observed following a longer standstill as the axial piston unit empty via the hydraulic lines. elow-reservoir Installation (tandard) elow-reservoir installation means the axial piston unit is installed outside of the reservoir below the minimum fluid level. 1 2 a min a min Especially with the installation position pump shaft upwards or pump shaft downwards, attention must be paid to completely filling and air bleeding the pump since there is a risk of dry running. 1 h t min h t min 1 The case drain fluid in the case interior must be directed to the reservoir via the highest case drain port (, 1, 2 ). For combinations of multiple units, make sure that the respective case pressure in each unit is not exceeded. In the event of the pressure differences at the drain ports of the units, the shared drain line must be changed so that the minimum permissible case pressure of all connected units is not exceeded in any situation. If this is not possible, separate drain lines must be laid. To achieve favorable noise values, decouple all connecting lines using elastic elements and avoid above reservoir installation. In all operating conditions, the suction line and the case drain line must flow into the reservoir below the minimum fluid level. The permissible suction height hѕ max = 31.50 in (800 mm). The minimum suction pressure at port must also not fall below 12 psi (0.8 bar) absolute during operation. 3 4 1 2 h t min Installation position Air bleed Filling 1 + 2 1 + 1 3 1) 2 + 2 4 + 1) Only series 53 Key on following page a min h t min 1 a min Installation Position: ee the following examples 1 thru 12 for proper plumbing of hydraulic lines for various pump installations. Installation positions 1 and 3 are the recommended conditions most favorable for a long extended life of the pump.

Installation Instructions: Variable Displacement Pump A10V, eries 52/53 Inside-reservoir Installation Above-reservoir installation Inside-reservoir Installation installation means the pump is Installation Above-reservoir instructions installation means the cont.: axial piston unit is installed Inside-reservoir within installation the minimum means the reservoir pump is installed fluid level. within installation means the axial installed above the minimum fluid level of the reservoir. the minimum reservoir fluid level. piston Above-reservoir unit is installed above the minimum fluid Axial piston units with electrical components To prevent the installation axial piston unit from draining, a height Inside-reservoir Axial piston units Installation with electrical components (e.g. electric level difference of the reservoir. he To prevent the axial piston (e.g. electric control, sensors) may not be installed Above-reservoir installation min of at means least 0.98 the in axial (25 piston mm) is unit required in Inside-reservoir control, sensors) installation may not means be installed the pump in is a installed reservoir within below the unit installed installation from above draining, the position minimum a 6. height fluid level difference of the reservoir. he min of the minimum in fluid a level. reservoir reservoir below fluid level. the fluid level. Observe the maximum permissible suction height at To least prevent 0.98 the axial in (25 piston mm) unit is from required draining, in a height installation Axial piston units with electrical components (e.g. electric h difference max = 31.50 in (800 mm). he min of at least 0.98 in (25 mm) is required in control, 9sensors) may not be installed in position 6. 10a reservoir below the installation A check position valve in 6. the case drain line is only permissible in fluid level. a individual cases. min a min Observe Observe the maximum the maximum permissible suction permissible height suction h max = 31.50 in (800 mm). height h max = 31.50 in (800 mm). 9 10 A check valve in the case drain line is only permissible in 1 1 a min a individual A check cases. valve in the case drain line is only min h t min h t min permissible in individual cases. 1 1 5 6 F h t min h t min F h E min 1 1 11 12 7 8 1 F 2 Installation position 1) Only series 53 h s max h t min h s max h t min a min a min Air bleed Filling 5 F, 1 (F) 6 F 1 (F) 7 1) F + 2 (F) 8 F + (F) F h s max h t min 1 h s max h t min a min a min 2 1 a min Installation position a min 11 12 2 1 h t min h t min 1 Air bleed 1 a min a min Filling 9 1, 1 Installation 10 Air bleed 1 Filling, 1 position 11 1) 2 9 1, 1 12 + 10 1, 1 11 1) uction uction port port 2 h t min h t min F 12 Filling / air bleeding +, 2, 1, 2 uction Case drain port port F Filling affle / Minimum (baffle air bleeding necessary plate) immersion depth (7.87 in, 1, 2 Case drain port ht min Minimum (200 mm)) necessary immersion depth (7.87 in (200 mm)) Minimum necessary spacing to reservoir base hmin Minimum necessary spacing to reservoir base h t min Minimum (3.94 necessary in (100 mm)) immersion depth (7.87 in (200 (3.94 mm)) in (100 mm)) Minimum necessary height needed to protect the hhe min min Minimum axial piston necessary unit spacing from height draining to reservoir needed (0.98 base to in (25 protect mm)). the axial (3.94 piston in (100 unit mm)) from draining (0.98 in (25 mm)) Maximum permissible suction height (21.50 in h E min Minimum (800 mm)) necessary height needed to protect the h max Maximum permissible suction height (21.50 in (800 mm)) axial piston unit from draining (0.98 in (25 mm)). amin When When designing the the reservoir, ensure adequate distance h max Maximum between distance permissible the between suction suction the line suction height and line the (21.50 and case the in case drain line. This (800 prevents mm)) the heated, return flow from being drawn directly a min When back from designing into being the suction drawn the reservoir, directly line. ensure back into adequate the suction distance line. between the suction line and the case