Model Number Structure

Similar documents
Model Number Structure

Model Number Structure

Model Number Structure

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

G3PE-Single-phase. Solid State Relays for Heaters

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Model Number Structure

G3PE-Single-phase. Solid State Relays for Heaters

Power Controller. (see note 1) 10 sec

High-power Solid State Relays G3PH

G3NA. Model Number Structure. Solid State Relays. Model Number Legend

Solid State Relays for Heaters

High-power Solid State Relays G3PH

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Model Number Structure

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Switching Power Supply

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Switching Power Supply

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Ordering Information. Text PCB Power Relay G5LE

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Solid State Relays for Heaters

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

Model Number Structure

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Safety-door Switch. Ordering Information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Inductive Proximity Sensor

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Model Number Structure

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

A22NK. Key-type Selector Switches

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Model Number Structure

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Subminiature Basic Switch

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Technical Information Solid State Relays. Glossary. Solid State Relays

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

H3DS-X - Solid State Two-Wire Timer

Small Limit Switch D4V

Tactile Switch (Hinged Type)

Digital display Pressure range ON/OFF output Linear output Model

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Hinged Safety Door Switch

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Manual Reset Limit Switch

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Ordering Information. Text Surface-Mounting Signal Relay G6K

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Product Data Sheet DV5214 NU

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Inductive Proximity Sensor

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Technical Information Solid State Relays. Glossary. Solid State Relays

Transcription:

Solid State Relays Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking terminals. (Except for 260B-VD and 450B-VD-2.) Applicable with 3-phase loads. Replaceable power element cartridges. Comply with VDE 0160 (finger protection), with a dielectric strength of 4,000 V between input and load. Comply with VDE 0805, IEC 950. Certified by UL, CSA, and VDE (reinforced insulation). Model Number Structure Model Number Legend @@@@-@-@ 1 2 3 4 5 6 7 1. Basic Model Name : Solid State Relay 2. Rated Load Power Supply Voltage 2: 0 VAC 4: 400 VAC 3. Rated Load Current 10: 10 A : A 30: 30 A 40: 40 A 50: 50 A 60: 60 A 4. Terminal Type B: Screw terminals 5. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 6. Certification VD: Certified by UL, CSA, and VDE 7. Special Specifications Blank: Standard models 2: 480-V models Solid State Relays J-21

Ordering Information List of Models Model Isolation Zero cross function Indicator Rated output load Rated input voltage 210B-VD Phototriac Yes Yes 10 A at 24 to 240 VAC 5 to 24 VDC 2B-VD coupler A at 24 to 240 VAC 240B-VD 40 A at 24 to 240 VAC 260B-VD 60 A at 24 to 240 VAC 210BL-VD No 10 A at 24 to 240 VAC 2BL-VD A at 24 to 240 VAC 240BL-VD 40 A at 24 to 240 VAC 260BL-VD 60 A at 24 to 240 VAC 210B-VD Yes 10 A at 24 to 240 VAC 24 VAC 2B-VD A at 24 to 240 VAC 240B-VD 40 A at 24 to 240 VAC 260B-VD 60 A at 24 to 240 VAC 4B-VD A at 180 to 400 VAC 12 to 24 VDC 430B-VD 30 A at 180 to 400 VAC 4B-VD-2 A at 0 to 480 VAC 430B-VD-2 30 A at 0 to 480 VAC 450B-VD-2 50 A at 0 to 480 VAC Note: When ordering, specify the rated input voltage. Replacement Parts Name Carry current Load voltage range Model Applicable VDE certification Power Device 10 A 19 to 264 VAC G32A-A10-VD DC5-24 210B-VD DC5-24 Yes Cartridge G32A-A10L-VD DC5-24 210BL-VD DC5-24 G32A-A10-VD AC24 210B-VD AC24 A G32A-A-VD DC5-24 2B-VD DC5-24 G32A-AL-VD DC5-24 2BL-VD DC5-24 G32A-A-VD AC24 2B-VD AC24 40 A G32A-A40-VD DC5-24 240B-VD DC5-24 G32A-A40L-VD DC5-24 240BL-VD DC5-24 G32A-A40-VD AC24 240B-VD AC24 60 A G32A-A60-VD DC5-24 260B-VD DC5-24 G32A-A60L-VD DC5-24 260BL-VD DC5-24 G32A-A60-VD AC24 260B-VD AC24 A 150 to 440 VAC G32A-A4-VD DC12-24 4B-VD DC12-24 30 A G32A-A430-VD DC12-24 430B-VD DC12-24 A 180 to 528 VAC G32A-A4-VD-2 DC12-24 4B-VD-2 DC12-24 30 A G32A-A430-VD-2 DC12-24 430B-VD-2 DC12-24 50 A G32A-A450-VD-2 DC12-24 450B-VD-2 DC12-24 Other Units (Order Separately) Units that Enable 2-line Switching of 3-phase Power Name Current flow Model Applicable Short-circuit Unit 10 A G32A-D 210B-VD, 210BL-VD A 2B-VD, 2BL-VD 4B-VD, 4B-VD-2 30 A G32A-D40 430B-VD, 430B-VD-2 40 A 240B-VD, 240BL-VD J-22 Solid State Relays

Specifications Ratings (at an Ambient Temperature of 25 C) Input Model Rated voltage Operating Voltage Input current Voltage level range impedance Must operate voltage Must release voltage 210B-VD 5 to 24 VDC 4 to 30 VDC 7 ma max. 4 VDC max. 1 VDC min. 2B-VD 240B-VD 260B-VD 210BL-VD 5 to 24 VDC 4 to 30 VDC ma max. 4 VDC max. 1 VDC min. 2BL-VD 240BL-VD 260BL-VD 210B-VD 24 VAC 19.2 to 26.4 VAC 1.4 kω±% 19.2 VAC max. 4.8 VAC min. 2B-VD 240B-VD 260B-VD 4B-VD 12 to 24 VDC 9.6 to 30 VDC 7 ma max. 9.2 VDC max. 1 VDC min. 430B-VD 4B-VD-2 430B-VD-2 450B-VD-2 Output Model Applicable load Rated load voltage Load voltage range Load current Inrush current 210B(L)-VD 24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.1 to 10 A 150 A (60 Hz, 1 cycle) 2B(L)-VD 0.1 to A 2 A (60 Hz, 1 cycle) 240B(L)-VD 0.5 to 40 A 440 A (60 Hz, 1 cycle) 260B(L)-VD 0.5 to 60 A 440 A (60 Hz, 1 cycle) 4B-VD 180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0.5 to A 2 A (60 Hz, 1 cycle) 430B-VD 0.5 to 30 A 440 A (60 Hz, 1 cycle) 4B-VD-2 0 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to A 2 A (60 Hz, 1 cycle) 430B-VD-2 0.5 to 30 A 440 A (60 Hz, 1 cycle) 450B-VD-2 0.5 to 50 A 440 A (60 Hz, 1 cycle) Refer to Engineering Data for further details. Solid State Relays J-23

Characteristics Item 210B(L)-VD 2B(L)-VD 240B(L)-VD 260B(L)-VD 4B-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models) 1 1/2 of load power source cycle + 1 ms max. (AC Input) 1 ms max. (-BL models) Release time 1/2 of load power source cycle + 1 ms max. (DC Input) 1 1/2 of load power source cycle + 1 ms max. (AC Input) Output ON 1.6 V (RMS) max. 1.8 V (RMS) max. voltage drop Leakage current 5 ma max. (at 100 VAC) 10 ma max. (at 0 VAC) 10 ma max. (at 100 VAC) ma max. (at 0 VAC) ma max. (at 400 VAC) 4B-VD-2 ma max. (at 480 VAC) 430B-VD ma max. (at 400 VAC) 430B-VD-2 450B-VD-2 ma max. (at 480 VAC) I 2 t 260 A 2 s 1,260 A 2 s 260 A 2 s 1,800 A 2 s 1,800 A 2 s 1,800 A 2 s Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric 4,000 VAC, 50/60 Hz for 1 min strength Vibration Destruction: 10 to 55 to 10 Hz, 0.375 mm single amplitude (Mounted to DIN track) resistance Shock Destruction: 300 m/s 2 (mounted to DIN track) resistance Ambient temperature Certified standards Ambient humidity Weight Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) UL508, CSA C22.2 (No.14, No.950), EN60950 File No. 5915ÜG Operating: 45% to 85% 260 g 340 g 460 g 900 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 6642ÜG 290 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 133127ÜG 290 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 6642ÜG 410 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 133127ÜG 410 g 900 g J-24 Solid State Relays

Operation Replacement Parts G32A-A Power Device Cartridge The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement. The damaged cartridge can be replaced with a new one without disconnecting the wires from the. Improve the heat radiation efficiency of the before replacing the cartridge. The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the short circuitry of the load, in which case the temperature indicator will not turn red. Be sure to turn OFF the power supply when replacing the Cartridge. Supplying power with the Cartridge removed may result in malfunction. Appearance G32A-A10(L)-VD G32A-A(L)-VD G32A-A40(L)-VD G32A-A60(L)-VD G32A-A4-VD(-2) G32A-A430-VD(-2) G32A-A450-VD-2 Replacing Power Device Cartridges When replacing Power Device Cartridges, use the specified model. Using a Power Device Cartridge other than the specified one will result in faulty operation and destruction of the elements. Solid State Relays J-25

Replacement Procedure G32A-A10(L)-VD/G32A-A(L)-VD/G32-A4-VD(-2) Use the special tool (provided) to extract the cartridge for replacement with a new one. Extraction Follow the procedures below to dismount the Power Device Cartridge from the. 1. Switch off the power. 2. Remove the terminal cover. 3. Hook the indented part of the cartridge with the tool and pull up on the cartridge to remove it. Hook here with Remover. Remover 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the. 3. Insert the cartridge into the opening of the so that the letters on the cartridge and those on the are in the same direction and side A and side B are even. Side A Apply silicone grease here. Side B Mounting Follow the procedures below to mount the Power Device Cartridge on the. 1. Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. 4. Attach the terminal cover. 5. Switch on the power and check the to be sure it works properly. G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the Unit. Extraction Follow the procedures below to dismount the G32A-A Power Device Cartridge from the. 1. Switch off the power. 2. Remove the terminal cover. 3. Loosen the two centered screws on the sides to dismount the cartridge. The screws are connected to terminals 1 and 2. Mounting 1. Apply silicone grease to the entire surface of the heat sink. Loosen Apply silicone grease here. 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the. Loosen 4. Loosen the screws on both the corners. Loosen Loosen 5. Hold the indented part of both the corners to dismount the cartridge. J-26 Solid State Relays

3. Insert the cartridge into the opening of the so that side A and side B are even. Side A 4. Tighten the screws on both the corners with a tightening torque of 0.59 to 0.78 N m. 5. Tighten the screws on both the sides with a tightening torque of 0.59 to 0.78 N m. 6. Attach the terminal cover. 7. Switch on the power and check the to be sure it works properly. Side B Terminal Connection Connecting with linking terminal for 210B(L)-VD, -2B(L)- VD, -240B(L)-VD and 4B-VD(-2), 430B-VD(-2). 1 2 1 2 Connecting with linking terminal for G32A. G32A Unit G32A Unit * 1. When s are close mounted, loosen the M3.5 Sems screw and flip the linking terminal down. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. 1. When are close mounted, loosen the M3.5 Sems screw on the G32A and flip the linking terminal down. * The cover will not fit if the terminal protrudes. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. Ensure that the linking terminal does not protrude. Connect the terminal with power off. terminal Refer to the instruction manual for the G32A-A Power Device Cartridge to replace the 's triac part. terminal 4B-VD terminal terminal When the temperature indicator has turned from pink to red, the G32-A-A Power Device Cartridge may have malfunctioned, in which case the cartridge must be replaced with a new one. Use the terminal cover to prevent accidents due to electric shock. Solid State Relays J-27

Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground 210B(L)-VD, 2B(L)-VD 240B(L)-VD 260B(L)-VD 25 2B(L)-VD 80 15 210B(L)-VD 60 40 25-30 - 0 40 60 80 100 Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) 4B-VD, 4B-VD-2 430B-VD, 430B-VD-2 450B-VD-2 Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) Note: Close mounting is possible for a maximum of three Units by reducing the load current by %. (A minimum clearance of 10 mm must be provided when mounting four or more Units.) J-28 Solid State Relays

Input Voltage vs. Input Current 2@0B-VD 4@0-VD, 4@-VD-2 Input impedance (kω) Input current (ma) 8 6 4 2 1 0.8 0.6 Input current Input impedance Ta = 25 C Input impedance (kω) Input current (ma) 10 T = 25 C 8 6 4 2 1 0.8 0.6 Input current Input impedance 0.4 0.4 0.2 0.2 0.1 1 2 4 6 8 10 40 Input voltage (V) 0.1 1 2 4 6 8 10 40 Input voltage (V) Horizontal Mounting Panel Ground 210B(L)-VD, 2B(L)-VD 240B(L)-VD 260B(L)-VD 2B(L)-VD 15 14 210B(L)-VD 11 10 7 11 5.5 10 5 3.5 28 60 42 40 18 30 0 40 60 80 100 Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) 4B-VD, 430B-VD 4B -VD-2, 430B-VD-2 450B-VD-2 430B-VD 4B-VD Ambient temperature ( C) Ambient temperature ( C) Solid State Relays J-29

Close Mounting (Up to Three) Panel Ground 30 27 18 15 13 9 7 5 4.5 DIN track 210B(L)-VD, 2B(L)-VD 2B-VD 210B-VD 240B(L)-VD 45 40 36 30 14 10 260B(L)-VD 64 48 40-30 - 0 40 60 80 100 Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) 4B-VD, 4B-VD-2 30 40 430B-VD, 430B-VD-2 16 10 30 24 10 30 10 30 80 100 Ambient temperature ( C) 450B-VD-2 30 10 30 80 Ambient temperature ( C) Ambient temperature ( C) J-30 Solid State Relays

One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. 210B(L)-VD 2B(L)-VD, 4B-VD, 4B-VD-2 240B(L)-VD/260B(L)-VD, 430B-VD, 430B-VD-2, 450B-VD-2 Inrush current (A. Peak) Inrush current (A. Peak) Inrush current (A. Peak) Energized time (ms) Energized time (ms) Energized time (ms) Solid State Relays J-31

Dimensions Note: All units are in millimeters unless otherwise indicated. 210B(L)-VD Without Terminal Two, M4 terminal B1 With Terminal 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 holes Terminal Arrangement/ Internal Connections Two, M3.5 Trigger circuit Input circuit terminal B2 4.6 x 5.6 elliptical hole 100 max. 2B(L)-VD Without Terminal Two, M4 terminal B1 With Terminal 4.6 dia. Mounting Holes Terminal Arrangement/ Internal Connections Two, 4.5 dia. or M4 holes Two, M3.5 Trigger circuit Input circuit terminal B2 4.6 x 5.6 elliptical hole 100 max. 240B(L)-VD Without Terminal terminal B1 Two, M5 With Terminal 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 holes Terminal Arrangement/ Internal Connections Two, M3.5 Trigger circuit Input circuit terminal B2 4.6 x 5.6 elliptical hole 100 max. J-32 Solid State Relays

260B(L)-VD 450B-VD-2 With Terminal 4.6 dia. Without Terminal Two, M5 Two, M3.5 Mounting Holes Two, 4.5 dia. or M4 holes Terminal Arrangement/ Internal Connections Trigger circuit Input circuit 4.6 x 5.6 elliptical hole 110 max. 100 max. 4B-VD, 4B-VD-2 Without Terminal Two, M4 With Terminal 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 Terminal Arrangement/ Internal Connections 7.6 90±0.2 terminal 67+B1 38100 max. 80 terminal B2 90±0.3 Trigger circuit Input circuit 8.6 2.2 8.8 Two, M3.5 25±0.2 4.5 4.5 x 5.6 elliptic hole 37 max. 100 max. 13.2 90 91 430B-VD, 430B-VD-2 Without Terminal Two, M5 With Terminal 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 Terminal Arrangement/ Internal Connections 7.6 terminal +B1 67 38 10090±0.280 max. terminal B2 90±0.3 Trigger circuit Input circuit 13 18 13 4.6 x 5.6 elliptic hole 35±0.2 47 max. 100 max. 4.5 35±0.3 89 91 Solid State Relays J-33

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Input Load Load power supply Load Connection For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz. The (VD) has a built-in varistor for overvoltage protection. At a low applied voltage, such as 24 VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. When attaching a heat sink to the (VD), in order to facilitate heat dissipation, apply silicone grease or equivalent heat-conductive grease on the heat sink. (Toshiba Silicone, Shinetsu Silicone, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N m. Noise Terminal Voltage according to EN55011 The (VD) complies with EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram. Input (VD) Output Load Loss time For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. Recommended Capacitor: 1 µf, 250 VAC Mounting The rated ambient temperature is 40 C. (30 C for 400 V.) Vertical mounting Close mounting Panel Vertical Vertical Vertical DIN track 80 mm DIN track Screw or DIN track mounting is possible. Vertical mounting should usually be used. Close mounting is also possible. Close mounting is possible for up to 3 s. (If there are 4 or more s, mount at intervals of 10 mm min.) Reduce the load current by 10% for 210B-VD, -2B-VD, -240B-VD and by % for 260B-VD, - 4B-VD(-2), -430B-VD(-2), -450B-VD-2. Leave a distance of 80 mm Horizontal mounting Panel With vertical mounting, reduce the load current by 30%. (Refer to the Load Current vs. Ambient Temperature graph.) Note: Leave a distance of 60 mm min. between s and ducts (especially above the ). J-34 Solid State Relays

Close Mounting Mounting Pitch Panel Mounting (At a rated ambient temperature of 40 C). Mounting direction Vertical direction Space between s Duct or airflow obstruction 80 mm min. min. 60 mm min. Close Mounting Between duct or airflow obstruction and 30 mm min. An uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the s and thus increase reliability. (Generally, each 10 C reduction in temperature will double the expected life.) 10 A A 30 A 40 A 60 A Required number of fans 0.16 0.31 0.47 0.62 0.93 per Example: For 10 s with load currents of A, 0.31 x 10 = 3.1 Thus, 4 fans would be required. Size of fans: 92 mm 2, Air volume: 0.7 m 3 /min, Ambient temperature of control panel: 30 C If there are other instruments that generate heat in the control panel other than s, additional ventilation will be required. Relationship between s and Ducts Duct Height Mounting surface Duct or airflow obstruction Vertical direction Duct or airflow obstruction Countermeasure (1) Countermeasure (2) Mounting surface 50 mm max. (A height of no more than half the 's height is recommended.) Mounting surface Airflow Do not surround the with ducts, otherwise the heat radiation of the will be adversely affected. Ventilation Use short ducts. If the ducts cannot be shortened, place the on a metal base so that it is not surrounded by the ducts. Be aware of air flow Duct or air flow obstruction Ventilation outlet Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. A heat exchanger, if used, should be located in front of the Units to ensure the efficiency of the heat exchanger. Please reduce the ambient temperature of s. The rated load current of an is measured at an ambient temperature of 25 or 40 C. Solid State Relays J-35

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K094-E1-06 In the interest of product improvement, specifications are subject to change without notice. J-36 Solid State Relays