PVM 220 Installation Guide

Similar documents
PVM 220 Installation Guide

PVM 220 Installation Guide

AVEdge 100 Installation Guide

Dukane Projection System (DPS)

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Specifications PLS 200D, PLS 210D, PLS 400D, and PLS 410D Digital Systems

Specifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems

Installation Instruction

Cable Cubby 1200 and 1400 Installation Guide

INSTALLATION MANUAL. Melink Corporation (513) Revision

Specifications PLS 201D, PLS 211D, PLS 401D, and PLS 411D Digital Systems

ZIP LIGHT LED LUMINAIRE

Cable Cubby 500 and 700 Installation Guide

800 Deere Rd. Prescott, WI CertiSafe Floor Mount

Cable Cubby 650 UT Installation Guide

TOYOTA im INTERIOR LIGHT KIT Preparation

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Retractor SM Installation Guide

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Product Manual MNX10043 REV 0 MODEL DSB. Dual Sensor Modular Switch box

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

TOYOTA CAMRY HANDS FREE BLU LOGIC Preparation

Cable Cubby 1202 and 1402 Installation Guide

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Environmental Distribution Center (EDC-06P-NH)

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

1/2 Ton Tahoe/Suburban/Yukon/Avalanche 4wd Part #: Rev

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Assembling a Wall-Mounted CTS

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Installation Instructions Table of Contents

poollux Power plx-pw60 & plx-pw100

INSTRUCTIONS. Power Panel. Installation Instructions

AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

General Installation Instructions LED

accqpulse Velocity Profiler Sensor Installation Guide

Installation Instructions

Model Numbers SAVI-NOTE75, SAVI-NOTE150

PROJECTOR ACCESSORIES

3875 Cypress Drive Petaluma, CA Fax

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Installation Instructions: ACCENT SYSTEM

TOYOTA RAV FOG LIGHT KIT Preparation

SCION tc 2014 FOG LIGHT KIT

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

INTEGRID TRACK (120V) SPECIFICATIONS

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Z22C-** Preconfigured Network Zone System

SCION im PREMIUM AUDIO Preparation

LED IMPORTANT SAFETY INSTRUCTIONS

1-3/8 Designer Metals Telescoping Traversing Rod Installation Instructions

SR-T5 LINE ARRAY SPEAKER. WALL PAN BRACKET (optional) SR-PB5 OPERATING INSTRUCTIONS

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

AquaPure Ei TM Series Replacement Kits

In-ceiling mount NDA-FMT-DOME. en Installation manual

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

USER'S MANUAL and INSTALLATION GUIDE

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Servicing the APU Generator Belt. Determining if a belt adjustment or replacement is required

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Desktop 5.5 Z Axis Retrofit

Job Sheet 1 Installing the Net Watt-Hour Meter

Installation Instructions: HYPERION R-Lite SYSTEM

Fiber optic splice closure

INSTALLATION INSTRUCTIONS

MNBRATKIT MidNite Brat Solar Charging Kit

Midnite Kid Basic Solar Charging Kit

VITALink Taped Splice Pigtail Crimp

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

Down and Out Motor Mount Assembly & Installation Directions

GN-3A Polaris General SSV Works 3 Speaker Audio Kit

CEILING SPEAKER SYSTEM

Ford Super Duty Recoil Traction Bar System. Part#: ,

Steel Outlet Boxes 4 11 /16" Welded

OBE-3-FT Outdoor Series

Hospital Grade Laminar Flow Common Plenum Ceiling System

»Product» Safety Warning

INSTALLATION INSTRUCTIONS

LEXUS GS 350/450h ILLUMINATED DOOR SILLS Preparation

INSTALLATION GUIDE INSTALLATION GUIDE

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Sensor3 Rack (SR3 and HSR3 Series) Installation Manual

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

MAPNET II Transceiver Installation Instructions

GPS AutoSteer System Installation Manual

INSTALLATION & OWNER S MANUAL

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

LoadMaxx. Installation Guide. For Trailers with Mechanical Suspensions. Air-Weigh Customer Support: PN R0

EMERY SKY SUSPENDED LED LUMINAIRE

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

ThermoLite 40W Solar Panel Installation Instructions

Transcription:

R CONFIG SELECT AUDIO AUX INPUT VOICELIFT PAGING SENSOR SENSITIVITY PVM 0 Installation Guide The Extron PVM 0 is an enclosure for the safe mounting of PoleVault system devices in the plenum area of a suspended ceiling. The main enclosure will fit on a x inch framed tile space and is used to mount a PoleVault System switcher and the power supply, and other optional Extron AV devices. The PVM 0 comes with a detachable device mounting plate that makes installation of PoleVault devices and accessories easier. The PVM 0 is UL Listed for use in plenum airspaces: meets UL 0 for heat and smoke release. Suitable for use in environmental air space in accordance with Section 00-(C) of the National Electrical Code, and Sections -8, -00() and -00 of the Canadian Electrical Code, Part, CSA C.. The product has been additionally investigated to UL 0, "Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces ". PVM 0 Enclosure Device Mounting Plate INPUTS AUDIO LEVEL ADJUST Figure. PVM 0 Installed (Access Door Open) PVS 0SA IP POLEVAULT SWITCHER E Access Door The following products are approved for use in the UL 0 rated Extron PVM 0 enclosure as part of the Extron PlenumVault System: PVS 0SA IP PoleVault Switcher PVS 0D PoleVault Switcher CC 00C Network Codec IPL 0 IP Link Controller SW HDMI Switcher In addition, any Extron product that has been individually tested and UL 0 approved can also be used. Contact Extron for a complete list of plenum rated products. The PoleVault switcher and other AV devices are not supplied with the PVM 0. For full installation, configuration, menus, connector wiring, and operation details of the PoleVault switcher, see the relevant PoleVault System Installation Guide, available at www.extron.com. Pre-installation IMPORTANT INSTRUCTIONS: Read all instructions before installing this enclosure. Installation of this product must be done by a qualified, professional installer. Installation of this product (including the wiring of devices) must meet national electrical codes, and local building standards and codes. A readily accessible disconnect device shall be incorporated in the building installation wiring. Building installation wiring to be protected by a UL Listed circuit breaker rated A or less. Observe all local and national building and safety codes, UL requirements, and ADA Accessibility Guidelines. Identify the location where the PVM 0 will be installed. Typically this would be a T-grid suspended ceiling with minimum x inch tiles, close to the display device location. Take into consideration access to a power source and the proximity of other utilities (gas, water, fire sprinklers and so forth). Also consider the other devices that are associated with the PoleVault switcher, such as speakers, input and output devices, wallplates and control devices, and the facility communication systems (such as a department information system). PVM 0 Features The PVM 0 is comprised of a main enclosure, an access door, and a device mounting plate (see figure ). The device mounting plate fits onto the door frame and allows access to the devices and cables when the door is open. Additional installation hardware is needed for this installation, and it should be supplied by the installer. Included hardware for installation: For Enclosure Installation Size and (Quantity) For (Quantity) Suspension cables feet x Á inch dia. () #-0 device mounting screws (0) Cable locks () Zip ties long (), short () Lag eye bolts ¼ x ¼ inch () Signal cable tie downs () Cable clamps inch (), ¾ inch ()

PVM 0 Installation Guide (Continued) Installation Step Remove device mounting plate from the access door. a. Open the access door and unscrew the two Phillips screws that are located in the bottom corners of the plate (left and right sides), near the door latches and door tether "T." Door Tether T a. Remove this screw on the right and left sides of the mounting plate. NOTE: Do not remove any of the screws located below the hinges. b. Swing the bottom of the plate up to separate it from the door frame, then slide the plate to the right until it becomes free of the hinge pins on the door frame. Retain the device mounting plate for later use (see step 6). Bottom of Door (inside right corner view) b. Swing the mounting plate out from the door frame and slide the plate to the right, off the hinge pins. Figure. Remove the mounting plate from the door. Step Remove ceiling tile and install suspension cables. For threaded rod installation see step, second section. a. At the location where the PVM 0 is to be installed, remove the ceiling tile and mark the T-grid for that tile then remove the adjacent tiles to make working on the grid easier. b. At an approximate angle of 0 degrees out from each corner of where the PVM 0 will be installed, mark and drill four holes in the structural Figure. Tie the cable to the ceiling anchor. ceiling for the suspension cable anchors. c. Screw a lag eye bolt (or an appropriate anchor) into each hole. d. Thread the looped end of the suspension cable though the bolt eyehole, pass the rest of the cable through the loop and tighten. Allow each cable to hang down. Thread the cable down through the cable lock, through the hole on the frame of the enclosure and back up through the lock. Step Suspend the main PVM 0 enclosure from the ceiling. a. Lift and place the PVM 0 enclosure carefully onto the T-grid so that it sits squarely on the grid. b. Holding a cable lock, press the locking pin down (following arrow directions) and pass the loose end of one the cables down through the large hole in the lock. Continue to push the cable down until about - inches of cable has exited the lock. c. Pass the loose end of the cable directly through the corner hole on the PVM 0 enclosure and then back up through the other large hole in the lock. Pass at least six inches of cable out through the top of the lock. d. Repeat for each corner. e. Adjust the cable tension through all locks, making each cable taut without lifting the PVM 0 off the T-grid. Cable Lock Locking Pin Figure. Secure the PVM 0 to the ceiling with cable on all corners.

Product Category For threaded rod installation inch or à inch diameter threaded rods are recommended to be used for installing this product. The threaded rod should be properly secured to the ceiling structure. For example, properly fasten a unistrut to the ceiling structure and attach threaded rods using nuts and washers. Secure the frame to the structural ceiling using threaded rods. To do this: a. Attach four rods to the support structure by using, for example a unistrut, one over each corner of the PVM 0 installation location. b. Attach a rod to each corner securing point of the PVM 0 with nuts and washers (see figure, at right). c. Adjust all the nuts to secure the PVM 0 to the ceiling, keeping it level and without lifting the unit from the T-grid. Insert threaded rods through holes on the ends of the mounting plate. Attach washers and nuts and secure. Step Run AC power wiring to the AC module in the PVM 0. If power is not available close to the installation location, install a junction box or power source at the area. This must be done by a qualified electrician and must meet local and national electrical, building and safety codes and all the regulatory requirements. See the Important Instructions on page. Use metal conduit only to run wire to the AC module. Do not run power cable in the same conduit as signal cables. Use AWG gauge solid copper wire only, as required by the installed power receptacles. Figure. Secure the PVM 0 to the ceiling with threaded rod. Run the power cable through metal conduit and wire it into the PVM 0 power module. To do this: a. Unscrew the two center screws (left and right side) of the power inlet/control panel and remove from the enclosure (see figure 6). b. Unscrew the two screws on the corners and detach the outer cover. c. Attach the metal conduit to the outer cover. Remove only the knockouts that are to be used for cabling. Leave intact the unused knockouts. The three knockout sizes are Œ inch to inch, to inch, and to inch. /" Conduit Knockout a. Remove power module from the PVM 0 enclosure. d. Run the wires through the conduit and connect to the AC receptacles. e. Reassemble the power module. f. Reattach the module to the enclosure. NOTE: The power module outlets must be used to power installed AV devices only. b. Remove the cover from power module. c. Attach a metal conduit. Figure 6. Remove the power module from the enclosure to attach the metal conduit.

R CONFIG AUX INPUT VOICELIFT PAGING SENSOR PVM 0 Installation Guide (Continued) Step Run signal and control cables to the PVM 0. Run the signal and control cables either into cable clamps or through conduit attached to the PVM 0 enclosure (see figure 7). To install a cable clamp on the enclosure: a. Select a suitable sized cable clamp for the quantity and thickness of cable to be fed into the enclosure. See the note on page, Step for knockout sizes. b. Identify the most suitable cable entry point and remove one or more knockouts as needed. NOTE: Remove only the knockouts that are to be used for cabling. Leave intact the unused knockouts. c. Remove the large nut from the back of the cable clamp and insert the clamp into the enclosure knockout from the inside. d. Place the nut on the clamp and tighten to secure. e. Pass the cables through the clamp into the enclosure. Leave enough cable slack at the PVM 0 to ensure cable connection to any device is maintained when the access door is open. f. Tighten down the cable grip until the cables are held firmly. Avoid damaging or bending cables at too sharp an angle.. Push the cable clamp into the knockout from inside the enclosure.. Attach the nut from the outside of the enclosure. Figure 7. Install a cable clamp on the PVM 0 enclosure (viewed from above). NOTE: See the PoleVault System Installation Guide for full cable connection details. Step 6 Install devices onto the device mounting plate. NOTE: The maximum door load is lbs (6.8 kg). Mount the PoleVault switcher with the front panel facing outwards in the marked location. Mount other optional devices as desired. To mount the devices and accessories: a. Carefully align the switcher with the appropriate holes in the marked location (indicated by arrows on the mounting plate). b. Secure the switcher with the supplied #-0» inch mounting screws, tightening each one until snug. Do not overtighten. c. Mount the power supply onto the device mounting plate in the marked location (indicated by arrows on the mounting plate), using the supplied screws. NOTE: Replacement power supplies must be either the equivalent Extron power supply, or a UL Listed NEC Class power supply. d. Mount any other devices following the procedures in the supplied device guide. Device Mounting Plate SELECT INPUTS AUDIO LEVEL ADJUST AUDIO SENSITIVITY PVS 0SA IP POLEVAULT SWITCHER E." (.6 cm) PoleVault Switcher Power Supply Figure 8. Install the devices onto the mounting plate. Step 7 Cut and install the ceiling tile in the access door. The door can accept a ceiling tile thicknesses of Œ- inches. Check the tile thickness before cutting. If the ceiling tiles have a specific pattern direction, ensure the overall pattern direction is maintained when cutting and fitting the cut tile insert into the access door. Cut the ceiling tile to x. inches and use that part for insertion into the access door..0" (.9 cm) a. Mark the dimensions ( inches by. inches) for the PVM 0 access door on the installation tile and cut the tile to size. Bottom of Door (Door Locks) b. With the access door open, insert the cut ceiling tile into the door frame (see figure 0, on page ). Example: x inch Ceiling Tile Figure 9. Cut the ceiling tile for insertion into the access door.

R CONFIG SELECT AUDIO AUX INPUT VOICELIFT PAGING SENSOR SENSITIVITY PVS 0SA IP Product Category Step 8 Install the device mounting plate onto the access door. To fit the mounting plate and devices on the access door: a. Align and slide the device mounting plate onto the two hinge pins located at the top of the door frame. b. Secure the plate into place with the two mounting plate screws, located at the bottom of the door frame. PVM 0 Enclosure Plate Hinges Plate (with devices installed) E Plate Hinge Pins POLEVAULT SWITCHER PoleVault Switcher (front panel facing down) INPUTS AUDIO LEVEL ADJUST Plate Screws Ceiling Tile Insert Door Frame Step 9 Connect the cables to the devices. Figure 0. Insert the ceiling tile and attach the device mounting plate to the access door (as viewed from below). See the PoleVault System Installation Guide or the relevant PoleVault switcher user guide for connecting cables and devices to the PVS device. For cable connections to optional devices see the relevant device guide or manual. Connect the fan cable (already installed in the enclosure) to the switcher power supply. Connect and dress the other cables as needed, providing enough slack to open and close the access door. Step 0 Verify and configure the setup. Turn on the power to all the devices. Verify and configure the system. See the PVS 0D User Guide, or PVS 0SA IP User Guide available at www.extron.com for full details. Step Attach the door tether to the door. The PVM 0 enclosure has a coiled door tether installed on the right side of the enclosure (when viewed from the front). After the device mounting plate is installed, the tether should be attached to the door to ensure safety when the door is opened. To attach the tether to the door: a. With the door fully open, locate the door tether attached within the enclosure. The coiled tether has a looped end to be attached to the door. b. In the lower corners of the door locate the cutout with a "T" shaped metal tab (see figure ). c. Stretch the tether and close up the door until the loop on the tether can be carefully slid over the "T" tab on the door. Ensure the loop is completely over the "T". d. Carefully lower the door to the full extent of the tether to ensure it functions correctly. Push the tether loop completely over the T tab on the door. Figure. Attach the Tether to the Door (as viewed from inside enclosure).

PVM 0 Installation Guide (Continued) Step Secure the door latches. Both door latches can be made secure so the door cannot be opened accidentally or inadvertently. To secure the latches close the door and tighten down the small set screws onto the latch (see figure ). For full safety secure both latches. To secure the latch from opening tighten down the set screw onto the latch. Figure. Secure the door latches (side of door view). PVM 0 Enclosure Dimensions 6." (6.0 cm).7" (60. cm).09" (6.0 cm).7" (60. cm) 6." (6.0 cm) 6 Extron Headquarters +.800.6.9876 (Inside USA/Canada Only) Extron Europe +...00 Figure. Enclosure Dimensions Extron Asia +6.68.00 Extron Japan +8...76 Extron China +86..760.68 Extron Middle East +97..99.800 Extron Korea +8...7 Extron India +9.80.0.777 0 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68-8-0 Rev. A 0