MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

Similar documents
SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

MG L 750kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

DATA CENTER SOLUTIONS

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES AND TANKS EPA TIER COMPLIANT

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

MD400. Industrial Diesel Generator Set. 400 kw Diesel. primary codes and standards. Standby Power Rating 500kVA 400kW 60Hz PARALLELING UNIT

MD300. Industrial Diesel Generator Set. 300 kw Diesel. primary codes and standards. Standby Power Rating 375kVA 300kW 60Hz

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

GENERAC GUARDIAN SERIES STANDBY GENERATORS

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

1P 120/240V, 3600 RPM,

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

60 Hz FEATURES. Exclusively from your Caterpillar dealer

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

D I E S E L G E N E R A T O R S E T S

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

DIESEL GENERATOR SET. 60 Hz FEATURES

DIESEL GENERATOR SETS

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Siemens Liquid Cooled Standby Generators

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

Diesel generator set QSK23 series engine

Diesel generator set QSK23 series engine

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Diesel generator set QSX15 series engine

DG175 GC to DG450 GC GAS GENERATOR SETS

Diesel generator set QSX15 series engine

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

Spark-ignited generator set

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

RENTAL DIESEL GENERATOR SET

Transcription:

Power Rating 130 k, 163 kva, 60 z Image used for illustration purposes only Codes and Standards Generac products are designed to the following standards: U2200, U508, U142, U489 CSA 22.2 BS5514 and DIN 6271 SAE J1349 NFPA 37, 70, 99, 110 NEC700, 701, 702, 708 ISO 3046, 8528, 9001 Powering Ahead For over 50 years, Generac has provided innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. e choose only engines that have already been proven in heavy-duty industrial applications under adverse conditions. Generac is committed to ensuring our customers service support continues after their generator purchase. NEMA ICS1, ICS10, MG1, 250, ICS6, AB1 ANSI/IEEE C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012) 1 of 6

STANARD OPTIONS ENGINE SYSTEM Oil Drain Extension Air Cleaner Fan Guard Stainless Steel Flexible Exhaust Connection Factory Filled Oil & Coolant Radiator Duct Adapter (Open Set Only) Critical Exhaust Silencer Fuel System Fuel ine - NPT Connection Primary and Secondary Fuel Shutoff Cooling System Closed Coolant Recovery System UV/Ozone Resistant oses Factory-Installed Radiator 50/50 Ethylene Glycol Antifreeze Radiator Drain Extension Electrical System Battery Charging Alternator Battery Cables Battery Tray Rubber-Booted Engine Electrical Connections Solenoid Activated Starter Motor ATERNATOR SYSTEM GENprotect Class Insulation Material 2/3 Pitch Skewed Stator Brushless Excitation Sealed Bearing Amortisseur inding Full oad Capacity Alternator GENERATOR SET Internal Genset Vibration Isolation Separation of Circuits - igh/ow Voltage Separation of Circuits - Multiple Breakers rapped Exhaust Piping Standard Factory Testing 2 Year imited arranty ( Rated Units) 1 Year arranty (Prime Rated Units) Silencer Mounted in the Discharge ood (Enclosed Only) ENCOSURE (if selected) Rust-Proof Fasteners with Nylon ashers to Protect Finish igh Performance Sound-Absorbing Material (Sound Attenuation Enclosures) Gasketed Doors Stamped Air-Intake ouvers Upward Facing Discharge oods (Radiator and Exhaust) Stainless Steel ift Off Door inges Stainless Steel ockable andles Rhino Coat - Textured Polyester Powder Coat Paint CONTRO SYSTEM Digital G-200 Paralleling Control Panel- Touchscreen Program Functions Programmable Crank imiter 7-Day Programmable Exerciser Special Applications Programmable ogic Controller RS-232/485 Communications 3 Phase Sensing Digital Voltage Regulator 2-ire Start Capability Date/Time Fault istory (Event og) Isochronous Governor Control aterproof/sealed Connectors Audible Alarms and Shutdowns Not in Auto (Flashing ight) Auto/Off/Manual Switch E-Stop (Red Mushroom-Type) NFPA110 evel I and II (Programmable) Customizable Alarms, arnings, and Events Modbus protocol Predictive Maintenance Algorithm Sealed Boards Password Parameter Adjustment Protection Single Point Ground 16 Channel Remote Trending 0.2msec igh Speed Remote Trending Alarm Information Automatically Annunciated on the Display Full System Status Display Power Output (k) Power Factor k ours, Total & ast Run Real/Reactive/Apparent Power All Phase AC Voltage All Phase Currents Oil Pressure Coolant Temperature Coolant evel Engine Speed Battery Voltage Frequency Alarms and arnings Oil Pressure Coolant Temperature Coolant evel ow Fuel Pressure Alarm Engine Overspeed Battery Voltage Alarms & arnings Time and Date Stamped Snap Shots of Key Operation Parameters During Alarms & arnings Alarms and arnings Spelled Out (No Alarm Codes) PARAEING CONTROS Auto-Synchronization Process Isochronous oad Sharing Reverse Power Protection Maximum Power Protection Electrically Operated, Mechanically eld Paralleling Switch Sync Check System Independent On-Board Paralleling Optional Programmable ogic Full Auto Back-Up Controls (PS) Shunt Trip and Auxiliary Contact 2 of 6

CONFIGURABE OPTIONS ENGINE SYSTEM Engine Block eater Oil eater Air Filter Restriction Indicator Stone Guard (Open Set Only) Critical Exhaust Silencer (Open Set Only/Standard on Ultra ow Emissions Option) EECTRICA SYSTEM 2.5A U Battery Charger 10A U Battery Charger Battery armer ATERNATOR SYSTEM Alternator Upsizing Anti-Condensation eater Tropical Coating Permanent Magnet Excitation CIRCUIT BREAKER OPTIONS Main ine Circuit Breaker Electronic Trip Breakers GENERATOR SET Genink Communications Software (English Only) Extended Factory Testing (3 Phase Only) IBC Seismic Certification 8 Position oad Center ENCOSURE Standard Enclosure evel 1 Sound Attenuation evel 2 Sound Attenuation Steel Enclosure Aluminum Enclosure AC/DC Enclosure ighting Kit Door Alarm Switch CONTRO SYSTEM Oil Temperature Sender with Indication Alarm Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) Remote Communication - Modem 10A Run Relay Ground Fault Indication and Protection Functions ARRANTY 2 Year Extended arranty 5 Year arranty 5 Year Extended arranty 7 Year Extended arranty 10 Year Extended arranty ENGINEERED OPTIONS ENGINE SYSTEM Coolant eater Ball Valves Fluid Containment Pans CONTRO SYSTEM Battery Disconnect Switch GENERATOR SET Special Testing Battery Box ENCOSURE Motorized Dampers Enclosure Ambient eaters Up to 200 MP ind oad Rating* RATING DEFINITIONS - See Bulletin 0187500SSB Prime - See Bulletin 0187510SSB *Consult factory for availability 3 of 6

APPICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Generac Cylinder # 8 Type V Displacement - (Cu In) 8.9 (540) Bore - mm (in) 114.23 (4.49) Stroke - mm (in) 107.15 (4.25) Compression Ratio 10.5:1 Intake Air Method Turbocharged/Aftercooled Number of Main Bearings 5 Connecting Rods Forged Cylinder ead Cast Iron Cylinder iners No Ignition igh Energy Piston Type Aluminum Alloy Crankshaft Type Forged Steel ifter Type ydraulic Roller Intake Valve Material Steel Alloy Exhaust Valve Material Stainless Steel ardened Valve Seats Yes Engine Governing Governor Electronic Frequency Regulation (Steady State) ±0.25% Cooling System Cooling System Type ater Pump Flow - gal/min (l/min) 26 Fan Type Pressurized Closed Pusher Fan Speed (rpm) 2330 Fan Diameter - mm (in) 558 (22) Fuel System Fuel Type Carburetor Secondary Fuel Regulator Fuel Shut Off Solenoid Operating Fuel Pressure (NG/PV) Operating Fuel Pressure (P) Engine Electrical System System Voltage Battery Charger Alternator Battery Size Battery Voltage Ground Polarity Natural Gas, Propane Vapor/iquid Down Draft Standard Standard (Dual) 7-11 2 O 30-312 psi 12 VDC Standard See Battery Index 0161970SBY 12 VDC Negative ubrication System Oil Pump Type Gear Oil Filter Type Full-Flow Spin-On Cartridge Crankcase Capacity - (qts) 8.5 (8.0) ATERNATOR SPECIFICATIONS Standard Model Generac 520 Poles 4 Field Type Revolving Insulation Class - Rotor Insulation Class - Stator Total armonic Distortion <5% Telephone Interference Factor (TIF) <50 Standard Excitation Brushless Bearings Single Sealed Coupling Direct, Flexible Disc Prototype Short Circuit Test Yes Voltage Regulator Type Full Digital Number of Sensed Phases 3 Regulation Accuracy (Steady State) ±0.25% 4 of 6

OPERATING DATA POER RATINGS Natural Gas Propane or Dual Fuel (NG+P) Three-Phase 120/208 VAC @0.8pf 130 k Amps: 451 130 k Amps: 451 Three-Phase 120/240 VAC @0.8pf 130 k Amps: 391 130 k Amps: 391 Three-Phase 277/480 VAC @0.8pf 130 k Amps: 195 130 k Amps: 195 Three-Phase 346/600 VAC @0.8pf 130 k Amps: 156 130 k Amps: 156 STARTING CAPABIITIES (skva) skva vs. Voltage Dip 480 VAC 208/240 VAC Alternator k 10% 15% 20% 25% 30% 35% Alternator k 10% 15% 20% 25% 30% 35% Standard 130 116 174 232 293 348 406 Standard 130 87 131 174 218 261 305 Upsize 1 150 133 199 265 332 398 464 Upsize 1 150 100 146 199 249 299 348 Upsize 2 200 187 280 373 467 560 653 Upsize 2 200 140 210 280 350 420 490 FUE CONSUMPTION RATES* Natural Gas ft 3 /hr (m 3 /hr) Propane Vapor - ft 3 /hr (m 3 /hr) Propane iquid - gal/hr Percent oad Percent oad Percent oad 25% 378 (10.7) 25% 204.2 (5.8) 25% 5.70 50% 791.2 (22.4) 50% 341.8 (9.7) 50% 9.54 75% 1144.5 (32.4) 75% 470.0 (13.3) 75% 13.12 100% 1496.0 (42.4) 100% 593.7 (16.8) 100% 16.57 * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOING Air Flow (inlet air combustion and radiator) ft 3 /min (m 3 /min) 5757 (163.0) Coolant Flow per Minute gal/min (l/min) 26 (98) Coolant System Capacity gal (l) 6.0 (22.7) eat Rejection to Coolant BTU/hr 302,400 Maximum Radiator Backpressure in 2 O 0.5 COMBUSTION AIR REQUIREMENTS Flow at Rated Power cfm (m 3 /min) 349 (9.9) ENGINE EXAUST Rated Engine Speed rpm 1800 Exhaust Flow (Rated Output) cfm (m 3 /min) 1341 (38.0) orsepower at Rated k** hp 200 Maximum Exhaust Backpressure in g (Kpa) 0.75 Piston Speed ft/min 1275 Exhaust Temp (Rated Output - Post Silencer) F ( C) 1112 (600) BMEP psi 162 Exhaust Size Outlet mm (in) 3.0" ID Flex (No Silencer) ** Refer to Emissions Data Sheet for maximum bp for EPA and SCAQMD permitting purposes. Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. 5 of 6

DIMENSIONS AND EIGTS* OPEN SET (Includes Exhaust Flex) x x (in (mm) 110 (2795) x 39.4 (1000.2) x 54.3 (1378) eight lbs (kg) 2674 (1213) STANDARD ENCOSURE x x (in (mm) 132.72 (3371.1) x 40.46 (1027.8) x 64.05 (1627) eight lbs (kg) Steel: 3434 (1558) Aluminum: 3055 (1386) EVE 1 ACOUSTIC ENCOSURE x x (in (mm) 154.13 (3914.9) x 40.46 (1027.8) x 64.05 (1627) eight lbs (kg) Steel: 3670 (1665) Aluminum: 3157 (1432) EVE 2 ACOUSTIC ENCOSURE x x (in (mm) 144.53 (3671) x 40.46 (1027.8) x 80.88 (2054.3) eight lbs (kg) Steel: 3789 (1719) Aluminum: 3207 (1455) * All measurements are approximate and for estimation purposes only. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIA DEAER Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. 6 of 6 Generac Power Systems, Inc. P.O.Box 8 aukesha, I 53189 P: (262) 544-4811 2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 0K6449C Rev. E 09/29/16