June 2009 Quick Selection Guide

Similar documents
Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Grilles Linear Grilles

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Ceiling swirl diffusers with perforated face plate

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Grilles Linear Grilles

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

SDV Vane Swirl Diffusers

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Ventilation grilles for installation into walls, sills or rectangular

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

LINEAR SLOT DIFFUSERS

FlowBar High Capacity Slot Diffuser

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Ceiling swirl diffusers

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Floor Swirls Models BZD and SZD

Ventilation grilles for installation into walls, sills or rectangular

Slot diffusers for ceiling installation

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

WGA Long throw nozzle grille

Wall and Ceiling Grille

Linear Floor Grilles Models FG, F20, F25 and FRO

Ventilation grilles for installation into walls, sills or rectangular

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Perforated Face Ceiling Diffusers

Ceiling swirl diffusers with perforated face plate

ceiling swirl diffuser DQJ

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

LINEAR SLOT DUFFUSERS

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

LINEAR BAR GRILLES. GRILLES-Linear Bar

Ceiling diffuser 4DE

For installation into ductwork

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Catalogue. FlowBar. High Capacity Slot Diffuser.

SERIES GSF. Fixed Swirl Diffusers (Patented)

SERIES GB. Adjustable Slot Swirl Diffusers

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

VARYCONTROL VAV Dual Duct Terminal Boxes

ceiling swirl diffuser Model DQJA / DQJR

Ceiling swirl diffusers

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Ceiling Slot Diffuser DSC

SERIES GZL. High Induction Linear Diffuser (Patented)

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Ceiling Swirl Diffuser DQJ

FIXED BLADE LOUVRE FACED CEILING DIFFUSER

Type VSD35. Nominal length up to 1500 mm: one spigot

KLIMA Active Chilled Beams

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Compact Grille Model KG

SERIES PG. Perforated Face

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Nozzle Jet Diffuser Model DSA

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

GDD - Supply Grille. Halton GDD. Supply Grille

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

SERIES HSL. High Capacity Linear

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Slot diffusers, Round duct diffusers. IMP Klima

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

SERIES MBD. Multi-Blade Linear Diffuser

series Linear grilles

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

SERIES GSL. Linear Slot Diffuser

Active Chilled Beams

Ceiling diffuser 4DF

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DRUM SLOT DIFFUSER TYPE: RT350

SERIES GP. Security Grilles

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Active Chilled Beams

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

SERIES H. Heavy Duty Adjustable Deflection Grilles

Transcription:

Issue Date June 2009 Quick Selection Guide

Quick Selection This selection guide has been designed to allow quick and simple selection for a broad range of TROX Grille and Diffuser product. Full product and system details for these and other TROX equipment can be found on our website www.troxuk.co.uk. As part of our commitment to a collaborative design process our local Sales Engineers are available to offer assistance and advice on these and other TROX systems and product. To contact you local engineer call 01842 754545. In addition to the Grille and Diffuser product in this guide, TROX offer a complete range of air distribution products and systems, these include: Active Chilled Beams Passive Chilled Beams Multi Service Chilled Beams (MSCB) Chilled Ceilings Fan Coil Units Acoustics Filtration VAV Terminal Units Labcontrol Dealer Desk Cooling Low to High Density Cooling TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 E-Mail: sales@troxuk.co.uk www.troxuk.co.uk

Contents Page Section1 - Adjustable Grilles AT/VAT 04 Section 2 - Extract Grille AE 06 Section 3 - Floor Grilles AFG 08 FB 10 Section 4 - Linear Grilles AH/WAP/AF 12 Section 5 - Transfer Grilles AGS/LCG/LVV40 14 Section 6 - Slot Diffusers VSD50 - High Capacity 16 VSD35 18 ALS-25 - High Capacity 20 ALS-20 22 Slot Diffuser Plenum Boxes 24 Section 7 - Fixed Blade Linear Diffuser ADM 26 Section 8 - Louvre Faced Diffusers Square Diffuser ADT 28 ADLQ 32 Circular Diffuser ADLR 34 Section 9 - Perforated Face Diffuser ADLQL 36 Section 10 - Disc Valves LVS/ZLVS 38 Section 11 - Swirl Diffusers Selection Methodology 40 SDW 42 VDW 44 FD 46 DCS 48 TDF 50 TDV 52 RFD 54 Section 12 - Jet Nozzles DUK 56 AJA 58

SECTION 1 Adjustable Grille Type VAT Supply or return air grille with individually adjustable vertical aerofoil blades. Front border 32mm wide with visible screw fixing (border counter-punched). Available on request with concealed fixing and sub frame. Adjustable Grilles Adjustable Grille Type AT Supply or return air grille with individually adjustable horizontal aerofoil blades. Front border 32mm wide with visible screw fixing (border counter-punched). Available on request with concealed fixing and sub frame. Sizes Available Minimum size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/... Order Code AT - AG / 800 x 200 / B30 / S11 / P3 / RAL 9010 / 20% Gloss Type AT = Horizontal front blade VAT = Vertical front blade Rear Assemblies A = Grille face only AG = Rear opposed blade damper D = Rear adjustable blades DG = Rear adjustable blades and damper L x H (mm) 0 = No subframe B30 = 75mm subframe bracket Powder coat finish Fixing Variant 0 = Without (screw fix) S11 = With (secret fix) X = Without flange drilling or secret fix Rear Assembly 75 107...-AG Opposed blade action volume control damper, adjustable from the front face. Type AT VAT 32 64...-D A set of individually adjustable vertical air pattern control blades. For type VAT these blades are horizontal. H / L 16,7 H + 45/L + 45 H + 22/L + 22 75 107...-DG Volume control dampers as...-ag plus a set of individually adjustable vertical air pattern control blades. Type AT shown 04

Performance Data Grille with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance from sidewall grille to an average velocity of 0.35 m/s. The minimum distance between multiple units must be 20% of Throw. Air Volume (l/s) 1100 1000 900 800 700 600 500 400 350 300 250 200 175 150 125 100 90 70 Throw (m) 10 8 6 5 4 3 Effective Jet Velocity (m/s) Pivot line 8 6 5 4 3 2 Pressure drop (total) (Pa) 60 40 20 10 5 Nominal width (mm) L 150 200 250 300 350 400 450 500 Pivot Line Nominal height (mm) H 100 150 200 250 300 350 SECTION 1 Adjustable Grilles 50 40 30 20 600 700 800 900 400 450 500 600 1000 1200 Throw assumes direction blades set at 45 blade divergence. For 0 blade divergence multiple throw by 1.4 and divide pressure drop by 1.1. By limiting effective jet velocity to 7 m/s all grille sizes shown meet NC35 assuming 8dB room attenuation and fully open damper. Subframe Secret Fixing Detail 32 Concealed fastener factory fitted to grille border L+6/H+6 Subframe fixed to surround (No 8 screw by others) 75 15 X Type B30-30mm border : X = 15 Screwdriver operation to locate fastener tongue behind subframe 05

SECTION 2 Eggcrate Grille Type AE Return air grille with fixed square pattern core. Front border 32mm with visible screw fixing. Available on request with concealed fixing. The grille is available with rear mounted opposed blade volume control damper adjustable from the front face. Size Available Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm. Extract Grilles For full details see publication 1/1.3/B/... Order Code Type AE AE - AG / 200 x 200 / B30 / S11 / P3 / RAL 9010 / 20% Gloss Rear Assemblies A = Grille face only AG = Rear opposed blade damper L x H (mm) Subframe 0 = without subframe B30 = 75mm subframe bracket Powder coat finish Fixing Variant 0 = Without (screw fix) S11 = With (secret fix) X = Without flange drilling or secret fix Screw Fixing Secret Fixing Detail Subframe Concealed fastener factory fitted to grille border L+6/H+6 Subframe fixed to surround (No 8 screw by others) 32 H / L 13 H + 22/L + 22 H + 45/L + 45 Screwdriver operation to locate fastener tongue behind subframe 15 X 75 Type B30-30mm border : X = 15 Rear Assembly 70 104...-AG 06

Performance Data Air Volume (l/s) 1000 500 400 300 200 Effective Jet Velocity (m/s) 7 6 5 4 3 2 Pressure drop (total) (Pa) 15 10 5 2 200 300 400 500 600 Nominal width (mm) L Pivot line Nominal height (mm) H 100 150 200 250 300 350 SECTION 2 Extract Grilles 1 400 100 0.5 700 450 Pivot line 800 500 50 900 600 1000 25 1100 1200 By limiting effective jet velocity to 7 m/s all grille sizes shown meet NC35 assuming 8 db room attenuation (no damper or damper fully open). 07

SECTION 3 Computer Room Floor Grille Type CFG/AFG Floor grille types CFG and AFG are specifically developed for mounting in Raised Access Floors in such areas as Computer Rooms, where load and damage resistance are of the utmost importance. Having a heavy duty construction, they can replace 600mm square floor tiles. Grille border depth can be specified to suit the type of floor system used. A range of surface finishes is available. The type CFG is a fan assisted computer room floor grille that eliminates hotspots and reduces risk of equipment failure by providing up to 5kW of cooling per cabinet. Floor Grilles The type AFG is a static grille assembly which can handle supply air or alternatively extract air and be fitted with rear opposed blade damper assembly for air volume flow control. For full details see publication PI/1/9/B/... Order Code CFG - F1 / 600 x 600 / 125 / 35 / P2 Type CFG AFG Rear Assembles F1 = Fan Pack (230V Standard) CFG only A = Face only, AFG only AG = Rear opposed blade damper, AFG only Size (mm) Unit Depth (mm) 125 = Standard *75 = Optional 0 = Not used AFG Frame Depth (mm) between face of grille and face of pedestal 25 standard Optionally 26-50 in 1mm steps 90mm Maximum Pedestal 599 +0.5/-1mm 13mm Nominal Pitch 6mm Detail A Note: 1) 75mm CFG depth option available X 125mm 1) P2 = Polyester powder coat silver grey RAL 9006 25% Gloss (Standard) P4 = Polyester powder coat black RAL 9006 20% Gloss N1 = Polyester powder coat with nylon reinforcing black RAL 9005 *Does not have the structural performance of 125mm unit Type CFG Type AFG Power Inlet Plug (C14) Detail A 140mm Approx 68.5 Shims to suit height required (factory fitted) 08 X standard 25mm. Can be 25-50mm in 1mm steps

CFG Fan Specification Watts/Motor 26 Total Watts 104 Amps/Motor 0.12 Total Amps 0.48 Motor 230V AC 50Hz Selection Guide The floor grille should be located at the front of the I.T./Comms cabinet experiencing hot spot conditions the cabinet should incorporate a perforated door. The floor void static pressure must be considered in the selection process (see Potential cooling below). Sufficient void air (cooled by others) must be available to be drawn by the grille at the specific point of need. Structural performance The 125mm deep unit will provide the following strength against the performance specification: CFG Acoustic Data Sound power level for one CFG 76dB(A) In an area with several units the noise level will increase due to multiple sources. To allow for this and room attenuation an assessment should be made by an acoustic engineer to ensure required room noise levels are achieved. Potential cooling 6.00 SECTION 3 Floor Grilles PSA MOB PF2 PS/SPU March 1992, with the following results: 5.00 5.11kW Test Stability of deflection (centre of grille): 4.5 kn static load through 25mm square indentor Impact load test: 40 kg Sand Bag from 1m height Dynamic rolling load test: 4.5 kn load 50 passes of wheel 3 kn load 50 passes of wheel 3 kn load 50 passes of wheel Safety load test (centre of grille): Result Deflection 23 hours after load applied - 3mm Deflection 24 hours after load applied - 3mm 0.09mm permanent deformation 0.01mm permanent indentation Did not collapse Did not collapse 0.40mm Vertical permanent deformation (max) 0.20mm Horizontal permanent deformation (max) kw Cooling Capacity 4.00 3.00 2.00 1.00 0.81kW 0.00 CFG AFG Grille (no fans) Note: Based on 10k rise across I.T. equipment with 1 Pascal floor void static pressure Air Volume (l/s) 600 500 400 300 200 100 0-15 -10-5 0 5 10 15 Floor Void Static Pressure (Pa) 13.5 kn load through 25mm square indentor Did not collapse CFG: 4 fans AFG: no fans 09

SECTION 3 Floor Grille Type FB Floor Swirl Diffusers available in either aluminium or plastic construction in a range of finishes/colours. Diffusers may be installed into a floor with either a pressurised void (no plenum box) or duct connection to optional side entry plenum box. Air discharge pattern may be adjusted to provide either horizontal or vertical by adjustment of optional control element (not type VF). For full details see publication 1/8/EN/... Floor Grilles Order Code - Aluminium Construction Type Surface of diffuser core and trim ring: Die cast and deburred 1 Die cast, deburred, tumble fettled 2 Die cast, deburred, tumble fettled 3 and polished black stove enamel paint, face skimmed natural Die cast, deburred, tumble fettled 4 face skimmed FBA - 1 - V - K - SM - A / 150 Size (mm) 150 200 K = Trim ring 1) Adjustable swirl element 2) vertical V directional control horizontal H vertical - fixed VF 3) A = Plenum box SM = Dirt trap including adjustable volume control at rear SV = Dirt trap including adjustable volume control at face 1) For orders without trim ring a spacing ring is provided for technical performance reasons and to ensure correct height of grille core. 2) For orders without adjustable swirl element the direction of air discharge is vertical. 3) Only available for size 200. Order Code - Plastic Construction Type FBK - 1 - V - K - SM - A / 150 / 0 / V00 Surface of diffuser, core and trim ring: Ash grey - similar to RAL 7037 1 Black - similar to RAL 9005 2 Adjustable swirl element 2) vertical V directional control horizontal H vertical - fixed VF 3) Size (mm) 150 200 A = Plenum box 0 = Standard polyamide (PA 6) V00 = Polyamide (PA 6-V0) SM = Dirt trap including adjustable volume control at rear SV = Dirt trap including adjustable volume control at face 1) For orders without trim ring a spacing ring is provided for technical performance reasons and to ensure correct height of grille core. 2) For orders without adjustable swirl element the direction of air discharge is vertical. 3) Only available for size 200. K = Trim ring 1) 1 2 10 3 4 5 6 1 Diffuser Core 2 Swirl element for adjustment of air discharge direction 3 Trim Ring 4 Clamping Ring 5 Dirt Trap 6 Plenum Box

Performance Data Size 150 200 ØR 1 Horizontal Discharge Vertical Throw (m) Discharge 0.3 m 0.9 m 1.2 m 1.5 m Air Volume (l/s) min - max 10-16 15-25 18-30 - 10-30 Press Drop (Pa) min - max 8-20 18-50 28-70 - 5-35 Air Volume (l/s) min - max 16-27 21-35 25-41 30-50 10-50 Press Drop (Pa) min - max 8-20 13-35 18-50 28-70 5-50 Max noise level NC38 assuming 4dB room attenuation. Data for FBA diffusers and dirt trap, damper fully open no plenum box. Horizontal discharge is Throw distance to terminal velocity of 0.15m/s (min vol) and 0.25m/s (max vol). A 600mm clear zone (from centre of diffuser) is recommmended with vertical discharge. Dimensions Size Ø D G E H 1 H 2 K 1 K 2 ØR 1 ØR 2 ØR 3 ØR 4 ØR 5 c1 c2 150 98 50 160 125 71.5 200 198.5 149.5 138 137 150.1 150.3 21 22 200 123 48 200 150 84 250 248.8 199.5 188 187 200.1 200.3 21 22 Diffuser core FBA/FBK c1 Clamping ring For installation in floor panels - min. 25mm thickness 21 ØR 5 SECTION 3 Floor Grilles 2 Adjustable swirl element to change direction of discharge Vertical/Horizontal (V,H) Vertical - fixed (VF) Clamping ring For installation in floor panels - max. 55mm thickness 2 ØR 2 ØR 2 Dirt trap SM/SV ØR 3 47 Trim ring K 1,5 Plenum box A 18 K 1 /K 2 G 24 ØR 4 70 c 2 H 1 4,5 ØD H 2 E 2 ØR 4-9,5 11

SECTION 4 Linear Grille Types AH - WAP Supply or return air grille with fixed horizontal profiled blades. Type AH - 5.5mm blades on 12.5mm pitch. WAP - 3mm blades on 12.5mm pitch. Front border 30mm wide, blades with either 0 or 15 deflection, Type AH-0 and AH-15 respectively, with visible screw fixing (border counter punched). Available on request with concealed fixing. Standard finish: Powder coated RAL9010 20% gloss. Linear Grilles Type AF Supply or return air grilles for lay in floor mounting with fixed horizontal profiled blades, blades with either 0 or 15 deflection. Type AF-0 and AF-15 respectively. The grille core is removable. The grille can be fitted into masonry. Standard finish: Powder coated RAL 9006 25% gloss. Sizes Available Minimum Size 150 x 100. Maximum Size 1800 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/... Order Code AH - 15 - AG / 1000 x 150 / B30 / S11 / P3 / RAL 9010 / 20% Gloss Type AF AH WAP AHR (20mm border) WAPR (20mm border) Blade deflection 15 0 L x H (mm) Rear Assemblies A = Grille Face only AG = Rear opposed blade damper D = Rear adjustable blades DG = Rear adjustable blades and damper Subframe 0 = No subframe B30 = 75mm subframe bracket (30mm borders) for finite grille B20 = as above but for 20mm border grille L30 = 1800mm subframe (30mm borders) for linear grille** L20 = as above but for 20mm border grille Powder coat finish Note: ** = Also for use when S11 fix plenum box supplied Fixing 0 = Without (screwfix) S11 = With (secret fix) X = Without flange drilling Rear Assembly 75 107...-AG Opposed blade action volume control damper, adjustable from the front face. Type AH - WAP Type AF H+30/L+30 12.5 32 64...-D A set of individually adjustable vertical air pattern control blades. H/L 12.5 H + 41(21)/L + 41(21) H/L AF-0 75 107...-DG Volume control dampers as...-ag plus a set of individually adjustable vertical air pattern control blades. AH-0 WAP-0 AH-15 WAP-15 12

Performance Data Linear grille (with aspect ratio >12 to 1) with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance from sidewall grille to an average velocity of 0.35 m/s. Air Volume (l/s.m) 400 350 300 250 200 175 150 125 L Throw (m) 20 15 10 5 Effective Jet Velocity (m/s) 7 6 5 4 3 2 1.5 Pressure drop (total) (Pa) 60 40 30 20 15 10 7 Nominal height (mm) H 75 75 100 100 150 Type AH/AF WAP AH/AF WAP AH/AF SECTION 4 Linear Grilles 100 80 70 2 1 Pivot line 150 200 WAP AH/AF 60 50 200 250 WAP AH/AF 40 300 250 AH/AF WAP 30 300 WAP By limiting effective jet velocity to 6 m/s all grille sizes shown up to 3m long meet NC35 assuming 8 db room attenuation and fully open damper. Subframe Secret Fixing Detail 32 Concealed fastener factory fitted to grille border L+6/H+6 Subframe fixed to surround (No 8 screw by others) 75 15 X Type B30-30mm border : X = 15 Type B20-20mm border : X = 5 Screwdriver operation to locate fastener tongue behind subframe 13

Transfer Grilles SECTION 5 Transfer Grille Type AGS Non vision grille for supply or return air with fixed inverted vee blades with visible screw fixing (border counter-punched). The nonvision grille is also available with a matching rear frame - Type AGS- T Transfer Grille Type LCG / LVV40 Pressed steel grilles and integral intumescent fireblock (1 hour rated), for use in fire rated doors and partitions. Size Available Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/... Order Code AGS - T / 250 x 250 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Type AGS AGS-T (Matching frame - T) L x H (mm) 0 = without subframe Powder coat finish 0 = Screwfix X = Without flange drilling Order Code - Fire Block LVV 40 / 150 x 150 Type LVV 40 L x H (mm) Note: For use with LCG Grilles Order Code - Pressed Steel Grille LCG / 150 x 150 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Type LCG L x H (mm) Powder coat finish 14

Performance Data AGS Neck Pressure Drop (Pa) 3 7 12.5 19.5 28 38 Size Jet Velocity 1 1.5 2 2.5 3 3.5 150 x 150 Volume (l/s) 7 10 14 17 20 24 200 x 150 Volume (l/s) 9 14 19 24 28 33 200 x 200 Volume (l/s) 15 23 30 38 45 53 300 x 200 Volume (l/s) 24 35 47 59 71 82 300 x 300 Volume (l/s) 38 57 76 96 115 134 400 x 300 Volume (l/s) 52 78 104 130 156 182 450 x 300 Volume (l/s) 59 88 117 147 176 205 450 x 450 Volume (l/s) 90 135 181 226 271 316 600 x 400 Volume (l/s) 110 164 219 274 329 384 500 x 500 Volume (l/s) 116 174 232 290 348 406 600 x 600 Volume (l/s) 171 256 341 426 512 597 800 x 600 Volume (l/s) 229 344 459 573 688 803 1000 x 600 Volume (l/s) 288 432 576 720 864 1008 1200 x 600 Volume (l/s) 347 520 694 867 1041 1214 By limiting effective jet velocity to 3 m/s all grille sizes shown meet NC35 assuming 8 db room attenuation. SECTION 5 Transfer Grilles LCG / LVV40 Neck NC20 NC25 NC30 NC35 Size Volume l/s T Pa Volume (l/s) T Pa Volume (l/s) T Pa Volume (l/s) T Pa 150 x 150 45 15 55 23 65 30 80 45 200 x 150 55 15 70 21 80 30 100 40 200 x 200 74 15 86 19 105 27 120 35 300 x 200 100 12 120 18 145 24 170 32 300 x 300 140 11 170 16 200 20 240 29 400 x 300 175 10 210 15 250 20 300 26 450 x 300 200 10 235 14 285 20 340 25 450 x 450 285 9 325 13 380 17 470 24 600 x 400 310 9 380 12 450 16 550 22 500 x 500 325 8 390 12 485 16 560 21 600 x 600 435 8 530 11 640 15 750 20 Data is for composite unit of 2No. grilles and integral fireblock. NC levels based on 8dB room attenuation. Type AGS Type AGS-T Type LCG/LVV40 H/L H 1 /L 1 H/L H 1 +10/L 1 +10 Intumescent mastic by others LVV40 intumescent fireblock min25 max44 LCG cover grille 15

Slot Diffusers SECTION 6 High Capacity Linear Slot Diffuser Type VSD50 The Type VSD50 slot diffuser is available with 1-4 slots. They are characterised by high induction, which results in a rapid decay of supply air velocity and temperature differential. The direction of air discharge can be adapted on site (by others) to the required room conditions. Size Available 1 to 4 slot lengths available in increments of 150mm. For full details see publication 2/2.7/B... Order Code - Diffuser VSD50 - BF - 2 - Z0 - A02 / 1200 / 0 / 0 / P3 / RAL 9010 / 20% Type VSD50 Style with Black Blades BF (finite) BL (linear) BN (non active) BE (mitre) Style with White Blades WF (finite) WL (linear) WN (non active) WE (mitre) Slots 1-4 Flange Z0 integral Length (mm) or mitre angle (deg ) A02 = End Angle P02 = End Plate Powder coat finish Fixings SB - support brackets CF - clip fixings BF - bridge fixings BX - bridge fixings for extended height plenum 0 - without Order Code - Plenum Box AKV - VSD50-4 - BF - D - M / 1200 x 248 x 2 x 430 / 0 / 0 Variable Plenum Diffuser Type Slots 1-4 Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum Spigot Dia (mm) Length (mm) M = Spigot Damper or no entry D = Lining or no entry Number of spigots 1-4 1) Overall Height (mm) (including diffuser plus any neck extension Y) 1) Minimum overall height including diffuser with CF fixing = spigot diameter + 81 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 107 mm + Y Note: For details of Plenum Boxes see page 24. 16

Performance Data Number of Slots 1 2 3 4 VSD50 Throw (m) 3.0 m 4.5 m 6.0 m Air Volume (l/s/m) min - max 20-55 20-70 20-80 Press Drop (Pa) max 22 36 47 Air Volume (l/s/m) min - max 40-80 40-100 40-115 Press Drop (Pa) max 14 22 29 Air Volume (l/s/m) min - max 60-100 60-120 60-145 Press Drop (Pa) max 10 15 20 Air Volume (l/s/m) min - max 80-115 80-140 80-165 Press Drop (Pa) max 8 13 18 SECTION 6 Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Blade configuration as detailed below to be set up on site, by others. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed below. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s. Slot Diffusers Perimeter Throw Pattern Example shown: 4 slot diffuser Façade 200 to 1000mm Throw (m) 300 150 Façade 2.7m Partition Wall Linear Slot Diffuser - Type VSD50 VSD50 = 59mm ALIGNMENT PIN DIM P mm Dimensions End Angle End Plate ALIGNMENT PIN SLOT Number of Slots Dim P (mm) 1.5 1 77.5 2 123.5 59 59 3 169 DIM P mm INTEGRAL Z0 FLANGE 4 215 11 1.5 17

SECTION 6 Linear Slot Diffuser Type VSD35 The type VSD35 slot diffuser is available with 1-6 slots. They are characterised by high induction, which results in a rapid decay of supply air velocity and temperature differential. The direction of air discharge can be adapted on site (by others) to the required room conditions. Size Available 1 to 6 slots lengths available in increments of 150mm. Slot Diffusers For full details see publication 2/2.6/B/... Order Code - Diffuser VSD35 - BF - 2 - Z0 - A02 / 1200 / 0 / 0 / P3 / RAL 9010 / 20% Type VSD35 Style with Black Blades BF (finite) BL (linear) BN (non active) BE (mitre) Style with White Blades WF (finite) WL (linear) WN (non active) WE (mitre) Slots 1-6 Flange Z0 integral Length (mm) or mitre angle (deg ) A02 = End Angle PO2 = End Plate Powder coat finish Fixings SB - support brackets CF - clip fixings BF - bridge fixings BX - bridge fixings for extended height plenum 0 - without Order Code - Plenum AKV - VSD35-4 - CF - D - M / 1200 x 198 x 2 x 346 / 0 / 0 Variable Plenum Diffuser Type Slots 1-6 Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum Length (mm) Spigot Dia (mm) M = Spigot Damper or no entry D = Lining or no entry Number of spigots 1-4 1) Overall Height (mm) (including diffuser plus any neck extension Y) 1) Minimum overall height including diffuser with CF fixing = spigot diameter + 73 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 99 mm + Y Note: For details of Plenum Boxes see page 24. 18

Performance Data Number of Slots 1 2 3 4 VSD35 Throw (m) 3.0 m 4.5 m 6.0 m Air vol. (l/s/m) min - max 15-40 15-50 15-50 Press drop (Pa) max 31 44 44 Air vol. (l/s/m) min - max 30-60 30-70 30-75 Press drop (Pa) max 15 23 26 Air vol. (l/s/m) min - max 45-70 45-85 45-95 Press drop (Pa) max 10 16 20 Air vol. (l/s/m) min - max 60-80 60-100 60-110 Press drop (Pa) max 9 14 17 SECTION 6 Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Blade configuration as detailed to be set up on site, by others. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s. Slot Diffusers Perimeter Throw Pattern Example shown: 4 slot diffuser Façade 200 to 1000mm Throw (m) 300 150 Façade 2.7m Partition Wall Linear Slot Diffuser - Type VSD35 VSD35 = 51.2mm ALIGNMENT PIN DIM P mm Dimensions End Angle End Plate Number of Slots Dim P (mm) 1.5 ALIGNMENT PIN SLOT 1 62 2 93 3 123 59 59 4 154 5 185 11 1.5 DIM P mm INTEGRAL Z0 FLANGE 6 215 19

Slot Diffusers SECTION 6 High Capacity Linear Slot Diffuser Type ALS25 Supply slot diffuser with integral baffle plate and air deflection blades. In the supply mode the discharge can either be set to horizontal or vertical direction by adjustment of the air deflection blades. Available as extract diffuser and also blanked dummy variant. For full details see publication 2/2.2/B/... Order Code - Diffuser ALS25 - T2-3 - A2 / 1200 / SB / 0 / P3 / RAL 9010 / 20% Gloss Type ALS25 Style S = Return (without blades) NA = Non-Active (without blades) E = Mitred corner (non-active without blades 300mm inside legs) T2 = (2 supply blades with spreader plate) Number of slots 1 to 4 Not Used Powder coat finish Fixings SB = Support Brackets CF = Clip Fixings BF = Bridge Fixings BX = Bridge Fixings for extended height plenum 0 = Without Length of diffuser in mm or Angle of mitre in degrees End Caps / End Plates A1 = One end cap fitted A2 = End cap both ends fitted P1 = One end plate fitted P2 = End plate both ends fitted 0 = None Order Code - Plenum AKV - ALS25-3 - BF - D - M / 1200 x 248 x 2 x 370 / 0 / 0 Plenum Diffuser Type ALS25 Number of Slots 1-4 Fix Type CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum Length (mm) Spigot (mm) M = Spigot Damper or no entry D = Lining or no entry Number of spigots 1-4 1) Overall Height (mm) (including diffuser plus any neck extension Y) 1) Minimum overall height including diffuser with CF fixing = spigot diameter + 98 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 122 mm + Y Note: For details of Plenum Boxes see page 24. 20

Performance Data Number of Slots 1 2 3 4 ALS25 Throw (m) 3.0 m 4.5 m 6.0 m Air vol. (l/s/m) min - max 20-55 20-70 20-80 Press drop (Pa) max 22 36 47 Air vol. (l/s/m) min - max 40-80 40-100 40-115 Press drop (Pa) max 14 22 29 Air vol. (l/s/m) min - max 60-100 60-120 60-145 Press drop (Pa) max 10 15 20 Air vol. (l/s/m) min - max 80-115 80-140 80-165 Press drop (Pa) max 8 13 18 SECTION 6 Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s. Slot Diffusers ALS25-T2-1 DIM A mm ALS25-T2-2 AIR BAFFLE PLATE IN EACH SLOT DIM A mm AIR DEFLECTION BLADES ADJUSTABLE FROM FACE 76 28 25 SLOT 28 DIM P mm 28 25 SLOT 19.5 25 SLOT 28 DIM P mm End Angle End Plate Dimensions 1.5 75 28 75 1.5 Number of Slots Neck A Face P 1 46.0 81.0 2 90.5 125.5 3 135.0 170.0 4 179.5 214.5 21

Slot Diffusers SECTION 6 Type ALS20 Supply slot diffuser with integral air straightener, hit and miss damper and deflection blades. In the supply mode the discharge can either be set to horizontal or vertical direction by adjustment of the air deflection blades. Available as extract diffuser and also blanked dummy variant. For full details see publication 2/2.1/B/... Order Code - Diffuser Type ALS20 Style S = Return (without blades) NA = Non-Active (without blades) E = Mitred corner (non-active without blades 300mm inside legs) T2 = (2 supply blades with spreader plate) ALS20 - T2-3 - A2 / 1200 / SB / 0 / P3 / RAL 9010 / 20% Gloss air Not Used Powder coat finish Fixings SB = Support Brackets CF = Clip Fixings BF = Bridge Fixings BX = Bridge Fixings for extended height plenum 0 = Without Length of diffuser in mm or Angle of mitre in degrees Number of slots 1 to 6 End Caps / End Plates A1 = One end cap fitted A2 = End cap both ends fitted P1 = One end plate fitted P2 = End plate both ends fitted 0 = None Order Code - Plenum AKV - ALS20-3 - BF - D - M / 1200 x 248 x 2 x 430 / 0 / 0 Variable Plenum Diffuser Type ALS20 Number of Slots 1-6 Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum Length (mm) Spigot (mm) M = Spigot Damper or no entry D = Lining or no entry Number of spigots 1-4 1) Overall Height (mm) (including diffuser plus any neck extension Y) 1) Minimum overall height including diffuser with CF fixing = spigot diameter + 98 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 122 mm + Y Note: For details of Plenum Boxes see page 24. 22

Performance Data Number of Slots 1 2 3 4 5 6 ALS20 Throw (m) 3.0 m 4.5 m 6.0 m Air vol. (l/s/m) min - max 15-45 15-55 15-55 Press drop (Pa) max 39 55 55 Air vol. (l/s/m) min - max 30-65 30-80 30-85 Press drop (Pa) max 19 29 33 Air vol. (l/s/m) min - max 45-80 45-95 45-105 Press drop (Pa) max 13 18 22 Air vol. (l/s/m) min - max 50-90 50-110 50-120 Press drop (Pa) max 9 14 16 Air vol. (l/s/m) min - max 70-100 70-125 70-135 Press drop (Pa) max 7 11 13 Air vol. (l/s/m) min - max 75-110 75-135 75-150 Press drop (Pa) max 6 9 11 Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern. SECTION 6 Slot Diffusers Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s. ALS20-DS-1 DIM A mm ALS20-DS-2 AIR BAFFLE/HIT & MISS SECTION IN EACH SLOT DIM A mm ADJUSTABLE FROM FACE AIR DEFLECTION BLADES 76 28 20 SLOT 28 DIM P mm 28 20 SLOT 19.5 20 SLOT 28 DIM P mm End Angle End Plate Dimensions 1.5 75 28 75 1.5 Number of Slots Neck A Face P 1 41.0 76.0 2 80.5 115.5 3 120.0 155.0 4 159.5 194.5 5 199.0 234.0 6 238.5 273.5 23

Slot Diffusers SECTION 6 Slot Diffuser Plenum Type AKV All plenums are supplied loose for site assembly to diffuser, Type CF clipped to diffuser prior to installation, Types BF & BX plenum pre-installed for 2nd fix diffuser. Plenum from pre-galvanised, mild steel natural finish. Damper Type M from pre-galvanised perforated sheet. Assembly supported by others (4 no holes provided at top edge of plenum). Plenum internally lined with 15mm black faced Class O foam if required. Order Code Variable Plenum Diffuser Type ALS20 ALS25 VSD35 VSD50 AKV - ALS20-3 - BF - D - M / 1200 x 248 x 2 x 430 / 0 / 0 Length (mm) Spigot (mm) Overall Height (mm) Number of spigots Number of slots Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum M = Spigot Damper or no entry D = Lining or no entry Plenum Lengths & Spigot Positions Spigot Lengths L L/4 L/2 L/4 Spigot Damper Order Suffix Spigot Length Dimension X Up to 178Ø 198 to 398Ø L Max = 2100 L Min = D+100 L Max = 2100 L Min = 2D+100 YES - M - 75mm 100mm NO - 40mm 40mm 24

Dimensions Type Number of slots W Bc Bb Ec Eb D Max 1 138 43 61 (D+98) (D+122) 198 2 176 82.5 100.5 (D+98) (D+122) 248 AKV-ALS20 3 214 122 140 (D+98) (D+122) 298 4 254 161.5 179.5 (D+98) (D+122) 353 5 310 201 219 (D+98) (D+122) 448 6 380 240.5 258.5 (D+98) (D+122) 498 1 138 48 66 (D+98) (D+122) 198 AKV-ALS25 2 214 92.5 110.5 (D+98) (D+122) 298 3 254 137 155 (D+98) (D+122) 353 4 310 181.5 199.5 (D+98) (D+122) 448 Type Number of slots W Bc Bb Ec Eb D Max 1 138 26.5 41 (D+73) (D+99) 198 2 176 57 71.5 (D+73) (D+99) 248 AKV-VSD35 3 214 87.5 102 (D+73) (D+99) 298 4 254 118 132.5 (D+73) (D+99) 353 5 254 148.5 163 (D+73) (D+99) 353 6 310 179 193.5 (D+73) (D+99) 448 1 138 41.5 56 (D+81) (D+107) 198 AKV-VSD50 2 176 87 101.5 (D+81) (D+107) 248 3 238 132.5 147 (D+81) (D+107) 348 4 310 178 192.5 (D+81) (D+107) 448 SECTION 6 Slot Diffusers Slot Diffuser Plenum Details Type BF Type CF Type BX or CF W X W X W X Bb Ø D (D+22) TYPICAL SLOT (VSD TYPE SHOWN) Eb O/A HEIGHT Bc Ø D (D+22) Ec O/A HEIGHT Bb EXTENSION Y Ø D (*) (D+22) Ec+Y) OR (Eb+Y) O/A HEIGHT Extended Neck Plenum (Type BX shown) Extension Y Maximum = 1150mm CF Types 1100mm BX Types Minimum = 25mm All Types 25

Fixed Blade Linear Diffusers SECTION 7 Linear Diffuser Type ADM Opposed blade damper can be provided and where diffuser length exceeds 1200mm, this should be mounted in the plenum box. Plenum box requirements should be forwarded to Trox for assessment/design proposals. Size Available Heights 150 to 450 in increments of 50mm. Length 300mm minimum For full details see publication 2/2.4/B/... Order Code Type ADM1 ADM2 Style A = Face only AG = Opposed blade damper 1) Note 1) Where supplied with plenum AG will be mounted in the plenum only. Screw Fixing Type O Standard Supply ADM1 - A / 1000 x 200 / 0 / 0 / P3 / RAL 9010 / 20% Gloss L x H (mm) Subframe 0 = without A00 = subframe Secret Fixing Detail Type N2 Optional Extra, Cross Bar fixing Powder coat finish Fixing Variant 0 = without (screwfix) S11 = with (secret fix) N2 = with crossbar fixing SB = with support bracket (mitred corner only) Type S11 Optional Extra subframe with concealed fasteners. Border drilled for fixing to duct 35 Opening size H x L Included in supply Duct 70 Type / A 140 Type / AG Opening size H + 6 L + 6 Type ADM1-A Type ADM2-A M-1A Opening size H x L Type-0 fix 2A Opening size H x L Type-0 fix 70 AG section 70 AG section 7 50 A section 7 50 A section 30 H-22 / L-22 125 Blade Pitch 30 30 H-22 / L-22 125 Blade Pitch 30 overall size H + 38 / L + 38 overall size H + 38 / L + 38 26

Performance Data Supply Aerodynamic Data ADM-1 H Pressure Drop (Pa) in mm <10 <10 12 20 28 38 150 Volume (l/s/m) 80 120 160 200 240 280 Throw (m) 3.3 5.0 6.7 8.4 10.0 11.7 200 Volume (l/s/m) 120 180 240 300 360 Throw (m) 4.1 6.1 8.2 10.2 12.3 250 Volume (l/s/m) 160 240 320 400 Throw (m) 4.7 7.1 9.5 11.8 300 Volume (l/s/m) 200 300 400 Throw (m) 5.3 7.9 10.6 350 Volume (l/s/m) 240 360 480 Throw (m) 5.8 8.7 11.6 400 Volume (l/s/m) 280 420 Throw (m) 6.2 9.4 450 Volume (l/s/m) 320 480 Throw (m) 6.7 10.0 Supply Aerodynamic Data ADM-2 H Pressure Drop (Pa) in mm <10 <10 12 20 28 38 150 Volume (l/s/m) 60 90 120 150 180 210 Throw (m) 2.0 3.0 4.1 5.1 6.1 7.2 200 Volume (l/s/m) 100 150 200 250 300 350 Throw (m) 2.6 3.9 5.3 6.6 7.9 9.2 250 Volume (l/s/m) 140 210 280 350 420 490 Throw (m) 3.1 4.7 6.2 7.8 9.4 11.0 300 Volume (l/s/m) 180 270 360 450 540 Throw (m) 3.5 5.3 7.1 8.9 10.6 350 Volume (l/s/m) 220 330 440 550 660 Throw (m) 3.9 5.9 7.8 9.8 11.8 400 Volume (l/s/m) 260 390 520 650 Throw (m) 4.2 6.4 8.5 10.7 450 Volume (l/s/m) 300 450 600 750 Throw (m) 4.6 6.9 9.2 11.5 SECTION 7 Fixed Blade Linear Diffusers The above selections meet noise levels up to and including NC35 assuming 8dB room attenuation. ADM linear diffuser with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s. 27

Louvre Faced Diffusers SECTION 8 Type ADT Square louvred face, removable core, ceiling diffusers type ADT giving horizontal air discharge, are suitable for use in rooms with ceiling heights between 2.60 and 4.00m. The recommended supply air temperature differential is ±10K. The ADT diffuser can be used for supply or extract air applications. ADT Plenum Box Manufactured from pre-galvanised mild steel. Supplied loose for site fixing with either side or top entry spigots, with or without spigot dampers. Plenums are also available internally lined if required and must be supported by the four holes provided on the top edge. For full details see publication PI/2/10.3/B/... Order Code - Diffuser Type ADTF ADTB ADTA ADTT ADTM** ADTS** ADTH*** Discharge 4 directions 3 2 2C 1 ADTF - 4 - AG / 225 x 225 / P3 / RAL 9010 / 20% 150 x 150 225 x 225 300 x 300 375 x 375 450 x 450 525 x 525 600 x 600* Size P3 P4 P6 Rear Ancillaries A Diffuser face only AG Opposed blade damper fitted to rear of diffuser State colour Gloss level Powder coated white RAL9010 20% gloss (standard) Powder coated black RAL9005 20% gloss Powder coated colour RAL... Blanking Plate BP-ADT / 450 Diffuser size Note: *ADTF only **only sizes 150 and 450 ***only size 375 Order Code - Plenum Box AKV - ADT - ZH - D - M / 450 x 248 x 300 x 380 / 0 / E / P4 / RAL9005 / 20% Variable Plenum Diffuser Type ZH AH ZV AV ADT Horizontal spigot (supply) Horizontal spigot (extract) Vertical spigot (supply) Vertical spigot (extract) Diffuser Size (mm) Spigot Dia (mm) 0 No damper M Spigot damper 2) MC Spigot damper cord operated 2) AGF Opposed blade damper fitted to rear of diffuser AGP Opposed blade damper fitted to body of plenum 0 No lining D Lining Plenum size (mm) Overall Height (mm) (including diffuser) 1) State colour Gloss level P4 Painted black RAL9005 20% gloss P3 Painted white RAL9010 20% gloss P6 Painted colour RAL... 0 Unpainted C Painted inside and out E Painted outside I Painted inside 1) For ZH, AH minimum height spigot diameter + 102 mm Minimum height with AGF/AGP damper, spigot diameter + 154 mm Minimum height with reduced size plenum + 30 mm on either of above For ZV, AV height fixed at 242mm or 272mm for full or reduced plenum respectively 2) Not available for vertical spigots 28

Diffuser Only Type ADTF performance data (without damper, if fitted, 100% open) 4-Way Discharge Nominal v k m/s 1.0 1.5 2.0 2.5 L x H Δp t in Pa 6 13 24 37 V in l/s L in m L pnc V in l/s L in m L pnc V in l/s L in m L pnc V in l/s L in m L pnc 150x150 4-way 25 0.8 < 36 1.0 < 50 1.5 22 60 2.1 27 225x225 4-way 55 1.2 < 80 1.5 < 105 2.1 19 130 2.7 26 300x300 4-way 95 1.5 < 140 2.2 < 190 3.1 22 240 3.7 28 375x375 4-way 150 1.8 < 225 2.7 < 300 3.7 24 375 4.3 30 450x450 4-way 210 2.1 < 320 3.4 < 425 4.3 25 530 4.6 32 525x525 4-way 290 2.7 < 430 4.0 18 575 4.6 27 720 5.2 32 600x600 4-way 375 3.1 < 560 4.3 19 750 4.9 28 940 5.5 34 < indicates values less than 15 Nomenclature: V in l/s Volume flow per diffuser L in m Distance from the outlet where the maximum time average air velocity is 0.5 m/s v k in m/s Diffuser neck velocity Δp t in Pa Total pressure drop L pnc NC rating of room sound pressure level based on an assumed 8dB room attenuation. Diffuser with plenum box Type AKV (side entry spigot) Performance is based on sizes and spigot sizes shown in table below. Note: The throw distance L should be between 75% and 100% of the distance to the nearest wall or 50% of the diffuser spacing dimension, based on a ceiling height of 2.7-2.9m. SECTION 8 Louvre Faced Diffusers Nominal L x H 150 225 300 375 450 525 600 Spigot ØD 123 198 248 313 313 313 313/398 Height E min 277 352 402 467 467 467 467/552 Noise level correction for plenum (damper 100% open) Function Size 150x150 225x225 300x300 375x375 450x450 525x525 600x600 1) 600x600 2) Supply ΔL pnc +11 +7 +9 +9 +10 +13 +16 +11 Extract ΔL pnc +11 +6 +5 +7 +9 +10 +12 +8 1) with 313 Ø spigot 2) with 398 Ø spigot Total pressure drop correction for plenum (damper 100% open) Function Size 150x150 225x225 300x300 375x375 450x450 525x525 600x600 1) 600x600 2) Supply F x2.2 x1.6 x1.6 x1.7 x2.4 x3.7 x5.0 x3.2 Extract F x2.2 x1.6 x1.7 x2.0 x2.6 x3.2 x4.3 x2.7 1) with 313 Ø spigot 2) with 398 Ø spigot General guidance on changing spigot diameter ØD with damper 100% open Spigot velocity m/s 2.5 3 3.5 4.0 Approx L pnc 25 30 35 40 Type AKV (Top entry spigot) The effect on performance is small providing spigot velocities do not exceed 3.5 to 4.0 m/s 29

Louvre Faced Diffusers SECTION 8 53 Nominal duct size L x H Type 150 225 300 375 450 525 600 ADTF ADTA/ADTB ADTT ADTH* ADTM/ADTS *Overall face 495mm lay on 500 mm square ceiling "T" supports Type ADTF 15 The type ADTF has a shaped flanged border for directly mounting to a closed flush ceiling (to maintain horizontal discharge) To fit over ceiling opening size (L+100) (H+100) Type ADTA - ADTB L x H (L + 145) (H + 145) O/A L x H Detail X & Y 53 Type ADTT (*ADTH) 7 The type ADTT has a flat flanged border to enable the diffuser face to be mounted on the back of an exposed T bar or directly to a closed flush ceiling Type *ADTH (size 375 only): 495 O/A to lay-on 500 square ceiling T supports Type ADTM - ADTS L x H (L + 145) (H + 145) O/A L x H 15 7 Z 53 53 (L + 150) (H + 150) O/A Type ADTA to locate in clip-in ceiling to match bevelled edge tile with PIP height = 27.5mm (ie SAS system 150) or 25mm (ie Burgess type A ) Type ADTB to locate in clip-in ceiling to match square edged tile with PIP height = 25mm (ie Burgess type B or D ) Detail X ADTA PIP heights (L + 133) (H + 133) O/A The types ADTM and ADTS each have a border designed to lay into an exposed Threadline support bar system Type ADTM to lay-on threadline ceiling T support bar 15mm wide x 16mm deep (dimension Z) Type ADTS to lay-on threadline ceiling T support bar 15mm wide x 8mm deep (dimension Z) Standard nom (L x H) sizes 150/450 Location clips on border (2 each on opposite sides) Standard PIP heights: 25mm or 27.5mm NB: Non-standard heights available on request Detail Y ADTB PIP heights Location clips on border (2 each on opposite sides) 25 Standard PIP height: 25mm NB: Non-standard heights available on request 30

Table 1 - Maximum Spigot Sizes L x H Side Entry Top Entry Nom. Max ØDmm Max ØDmm Available for diffusers type 150 148 123 ADT / F / A / B / T / M / S 225 222 198 ADT / F / A / B / T 300 298 278 ADT / F / A / B / T 375 353 353 ADT / F / A / B / T / H 450 448 2) 398 ADT / F / A / B / T / M / S 525 498 2) 498 ADT / F / A / B / T 600 558 2) 558 ADT / F / A / B / T Table 3 - Overall height diffuser + plenum Plenum Option E min E max F min F max AKV-ADT 0 & M D+102 1000 D+132 1000 AKV-ADT AGF/AGP D+154 1000 D+184 1000 Notes: 1) Also available with cord operated damper type MC 2) 398 is maximum ØD for type M or MC dampers 3) For performance guidance information on spigot size selection see page 29 (L-2) (H-2) X 25 Table 2 - Available spigot sizes 3) ØDmm Subiect to limitations as shown in table 1 & as noted 98 198 348 123 222 398 138 248 448 148 278 498 158 298 558 178 313 Table 4 - ADT Side Entry Spigot Damper Order Suffix (L 1-2) (H 1-2) X Effective Spigot Length Dimension X Up to 178Ø 198 to 398Ø YES - M - 75mm 100mm NO - 40mm 40mm Reduced plenum sizes Effective plenum size L1 x H1 must be at least one size down on nominal L x H. 25 SECTION 8 Louvre Faced Diffusers E O/A height required (refer to table 3) Option type M 1) Option type AGF ØD (Refer table 2) ADTF border style shown (refer table 1) F O/A height required (refer to table 3) Option type M 1) ØD (Refer table 2) Option type AGP fitted to the plenum (L-2) (H-2) I/S (L 1-2) (H 1-2) I/S Plenum D D 40 40 Option type AGF 242 272 Option type AGP fitted to the plenum Notes: 1) For full plenum code details refer to page 28 2) All plenums, and if required transformations, are supplied loose for site assembly by others 3) All full size plenums are supplied with clips for diffuser face fixing 4) Holes (4) provided at top edge of plenum for hanging by others 5) AGF and AGP damper adjustment requires core removal 6) Plenum can be internally lined code D (lining material 12mm black faced class O) foam 31

Louvre Faced Diffusers SECTION 8 Square Diffuser Type ADLQ Type ADLQ high capacity ceiling diffuser comprises a fixed diffuser face with plenum box supplied loose (to be fitted by others), where specified. Low pressure drop and noise levels due to curved blade construction. Available as a four-way face configuration. For full details see publication 2/11/EN/... Order Code - Diffuser Type A = Diffuser face AG = With OBD AR = With rear mounting ring ADLQ - A / 250 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Size (mm) 250 300 400 500 600 625 Not Used Subframe 0 = Without installation subframe E1 = Duct cross bar Powder coat finish Order Code - Plenum AK - ADLQ - ZH - D - M / 400 x 198 x 6 / 0 / 0 Plenum Diffuser Type ZH = horizontal spigot (supply) AH = horizontal spigot (extract) ZV = vertical spigot (supply) AV = vertical spigot (extract) Diffuser Size M 1) = Spigot, damper or blank D = Lining or no entry Spigot size Not Used Reduced plenum size or blank if standard diffuser size Note : 1) Only available for horizontal spigot (ZH, AH) 32

Performance Data Supply (4 - Way Discharge) Size 250 300 400 500 600 Extract Lwnc 15 21 25 30 35 Pressure Drop (Pa) 10 15 20 30 45 Volume (l/s) 30 38 45 55 62 Throw (m) - - 1.0 1.2 1.4 Volume (l/s) 45 53 65 80 95 Throw (m) - - 1.0 1.2 1.3 Volume (l/s) 80 100 115 150 170 Throw (m) - 1.1 1.2 1.9 2.5 Volume (l/s) 135 160 175 225 275 Throw (m) - 1.2 1.6 2.0 2.7 Volume (l/s) 210 275 290 350 450 Throw (m) - 2.0 2.1 2.75 3.5 Size Lwnc 15 21 25 30 35 Pressure Drop (Pa) 10 15 20 30 45 250 Volume (l/s) 30 38 45 54 60 300 Volume (l/s) 50 60 70 90 100 400 Volume (l/s) 90 110 125 170 200 500 Volume (l/s) 180 200 250 300 375 600 Volume (l/s) 300 375 450 500 600 SECTION 8 Louvre Faced Diffusers ADLQ louvre diffuser with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s for a 4-Way discharge. All selections shown meet NC35 assuming 8 db room attenuation. Dimensions Type ADLQ-AK Size ØD H K Q1 Q2 250 158 262 204 248 198 300 158 262 254 298 248 400 198 307 354 398 348 500 248 357 454 498 448 600 313 420 554 598 548 K 50 ØD Type ADLQ-AR H Q 2-55 ADLQ-AR Q 1 Type ADLQ-AG Type ADLQ-A 108 Q 2-58 42 65 Q 2 Q 1 33

Louvre Faced Diffusers SECTION 8 Circular Diffuser Type ADLR Aluminium diffusers Type ADLR and ADLR-Q are recommended for flush installation in ceilings. Circular or square configurations can be used in standard ceiling systems. Plenum boxes are available with top or side entry. For full details see publication 2/16/EN/... Order Code Type ADLR (Circular diffuser) Q = Square diffuser (or blank) A = Diffuser face C = With flap damper AR = With connecting ring Top entry plenum ZV = Supply air AV = Extract air Side entry plenum ZH = Supply air AH = Extract air M = Damper in plenum box spigot 4) MN = Volume setting by cord and measurement test point L = Spigot with lip seal Accessories RZ Circular flap damper and equalising grid Please order accessory RZ separately stating size required 2) Size of Face section 593 598 Size of Diffuser 1 2 3 4 5 6 7 8 No entry for standard construction ADLR - Q - ZH - M - L / 598 x 4 / 0 / 0 / S1 / RAL 9016 0 = Standard surface finish stove enamelled to 3) RAL 9010 S1 = Stove enamelled to RAL... 0 = Without subframe 1) D0 = Duct subframe 1)F0 = Standard subframe State colour Type ADLR - Q 593 - for installation in visible T-bar 598 - for installation in ceiling grid with rear sub-structure 1) Required on constructions without plenum box 2) Only on variants with square face section Type ADLR - Q 3) GL = Gloss level 50-60% 4) Available side entry plenum only Type ADLR-Q Type ADLR-Q K ØB ØD 35 H 1 H 2 6 ØD ØP ØR 1 (ADLR) ØR 1 (ADLR) 34

Performance Data Diffuser Centres (m) Size Selection Method 1.2 (m) 1.8 (m) 2.4 (m) 3.0 (m) 3.6 (m) 4.2 (m) Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1 Linear Pattern 35 22 55 60 80 130 - - - - - - Square Pattern 32 19 45 35 60 68 - - - - - - 2 Linear Pattern 50 15 80 35 110 70 - - - - - - Square Pattern 35 7 55 17 80 35 100 58 - - - - 3 Linear Pattern 60 7 95 17 130 30 175 60 - - - - Square Pattern 50 5 65 8 95 17 130 30 155 50 - - 4 Linear Pattern - - 110 13 150 25 200 35 250 55 300 85 Square Pattern - - 70 5 100 10 140 19 180 32 220 40 5 Linear Pattern - - - - 180 23 230 37 280 65 360 90 Square Pattern - - - - 130 12 160 19 200 25 260 50 6 Linear Pattern - - - - 220 15 260 25 330 40 400 50 Square Pattern - - - - 150 9 180 13 220 15 290 30 7 Linear Pattern - - - - 240 15 290 20 360 37 450 50 Square Pattern - - - - 175 8 210 10 270 19 330 32 8 Linear Pattern - - - - 250 13 320 22 400 30 500 50 Square Pattern - - - - 180 7 220 10 280 17 360 28 Linear Pattern based on a single row of Diffusers. Square Pattern with Diffusers at equal centres. Ceiling diffuser with ceiling effect (horizontal throw). At diffuser centres shown, maximum terminal velocity is 0.25 m/s at 1.0m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). SECTION 8 Louvre Faced Diffusers Dimensions Size Ø B Ø D H 1 H 2 K Ø P Ø R 1 Ø R 2 1 201.5 123 233 220 266 202 244 192 2 257.5 158 233 250 290 258 300 248 3 313.5 198 233 295 372 314 356 304 4 369.5 248 267 345 476 362 412 360 5 425.5 248 267 345 476 426 468 416 6 481.5 313 298 410 567 482 542 472 7 537.5 313 298 410 590 578 598 528 8 593.5 313 298 410 615 590 654 584 Type ADLR Type ADLR-Q Type ADLR-AR/ADRL-Q-AR ØR 2-55 35 ØR 2-55 35 ØR 2-51 60 ØR 2 ØR 1 ØR 2 593 or 598 35

Perforated Face Diffusers SECTION 9 Perforated Diffuser Type ADLQL Type ADLQL ceiling diffuser comprises a perforated diffuser face with rear plenum box, top or side entry. Spigot dampers are only available with side entry plenums. Blanking plates are available on request for site fitting by others. For full details see publication 2/15.1/B/... Order Code Type K = 27mm cover border P = 11mm flush border Supply ZH = horizontal spigot ZV = vertical spigot Extract AH = horizontal spigot AV = vertical spigot ADLQL - K - ZH - D - M / 300 X 158 X 0 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Size (mm) 300 400 500 600 295 2) 595 2) M = spigot 1) damper or blank D = Lining 1) or blank Not used Reduced plenum size or blank if standard diffuser size Spigot size Powder Coat finish Note: 1) Only available for horizontal spigot 2) Only available for flush border & layin T bar Dimensions Size Ø D DA1 DA2 H1 H2 H3 K1 K2 Q1 Q2 300 158 290 300 300 75 83 274 269 336 298 400 198 390 400 340 75 83 374 369 436 398 500 248 490 500 390 75 83 474 469 536 498 600 313 590 600 455 75 83 574 569 636 598 295 158-300 300-83 271 266-295 595 313-600 455-83 571 566-595 Blanking Plates ates Blanking plate 36

Performance Data Type ADLQL-K-H Supply (4 - Way Discharge) Extract Note: Size Pressure Drop 10 15 20 25 30 300 Volume (l/s) 45 60 70 78 85 Throw (m) 0.7 0.8 1.0 1.1 1.2 400 Volume (l/s) 80 100 118 130 145 Throw (m/s) 0.85 1.1 1.3 1.4 1.5 500 Volume (l/s) 110 135 158 175 190 Throw (m) 0.85 1.1 1.4 1.5 1.6 600 Volume (l/s) 170 210 240 260 290 Throw (m/s) 1.2 1.4 1.6 1.8 2.0 Size Pressure Drop 10 15 20 25 30 300 Volume (l/s) 80 105 120 135 150 400 Volume (l/s) 105 130 150 170 180 500 Volume (l/s) 135 160 185 210 225 600 Volume (l/s) 210 260 300 330 360 Pressure drop and acoustic data shown is for top entry spigot. For side entry supply & extract acoustic and pressure drop data refer to leaflet 2/15.1/B/... Horizontal throw distance from diffuser to a velocity of 0.5 m/s for a 4-Way discharge. All selections shown meet NC35 assuming 8 db room attenuation. Type ADLQL-P-H SECTION 9 Perforated Face Diffusers K 1 K 1 H 1 H 1 ØD ØD 8 D A1 Q 1 Q 2 D A2 Type ADLQL-K-V K 2 ØD Type ADLQL-P-V K 2 ØD H 2 8 H 3 D A1 Q 1 Q 2 DA 2 37

Disc Valves SECTION 10 Disc Valve Type LVS Z-LVS The disc valves consist of a valve ring, central disc and installation subframe. To guarantee a perfect seal, the valve ring is fitted with a peripheral sealing strip. A bayonet fitting is used to mount the unit in the installation subframe. The air volume flow is adjusted by rotating the central disc which alters the gap between the disc and the valve ring. The central disc is held in position with a locknut. For full details see publication 1/4/EN/... Order Code LVS / 160 / G1 Supply Z - LVS Extract LVS Size Ø (mm) 100 125 160 200 G1 - Subframe O - No Subframe Type LVS (Extract Valve) Type Z-LVS (Supply Valve) 50 50 S ØE ØC ØD ØE ØC ØD 8 8 B B Dimensions Size B C D E 100 40 99 132 104 125 46 124 162 129 160 54 159 205 164 200 61 199 245 204 38

Performance Data Type LVS (Extract Valve) Size 100 125 160 200 Air gap Air Volume (l/s) (mm) S 10 20 30 40 50 60 80 100 120-15 - - - - - - - - - -5 30 120 - - - - - - - 0 12 50 112 300 - - - - - +5 5 28 56 100 - - - - - -15 70 270 - - - - - - - -5 14 50 100 200 - - - - - 0 5 25 50 89 139 - - - - +5 <5 15 30 52 81 - - - - -15 17 70 157 - - - - - - -5 <5 15 36 64 100 144 - - - 0 <5 10 22 38 61 88 - - - +5 <5 5 12 20 33 48 85 - - -15 5 22 50 89 140 190 - - - -5 <5 8 17 30 47 68 120 175 220 0 <5 <5 11 20 30 40 77 120 150 +5 <5 <5 <5 15 23 30 50 85 100 Pressure drop (Pa) SECTION 10 Disc Valves Type Z-LVS (Supply Valve) Size Pressure drop (Pa) 10 20 30 50 70 100 Volume (l/s) 10 15 18 23 28 Throw (m) 0.7 1.1 1.5 2.0 2.7 125 Volume (l/s) 13 18 21 28 33 Throw (m) 0.9 1.4 1.6 2.0 2.7 160 Volume (l/s) 15 22 27 35 42 Throw (m) 0.9 1.5 1.8 2.5 3.0 200 Volume (l/s) 20 28 35 45 55 Throw (m) 1.5 2.1 2.8 3.8 4.5 Note: Maximum Noise Level NC38, assuming 8dB room attenuation. Throw to a terminal velocity of 0.2 m/s. Performance based on air gap dimension S = 9mm. 39

Swirl Diffusers SECTION 11 Swirl Diffuser Selection Methodology Swirl diffusers offer a high induction air distribution method that enables the highest comfort criteria to be achieved. The following range of diffusers each discharge an air stream horizontally across the ceiling. The entrainment and expansion takes place rapidly, and the velocity decay of the air-stream occurs in direct proportion with the distance from the device. High turbulence occurs immediately within the proximity of the diffuser, which allows high air change rates to be successfully supplied into the room. With careful selection swirl diffusers can handle up to 30 air changes per hour while still satisfying relevant comfort criteria. Minimum Diffuser Centres A, B or C 2.7m 1.0m X V H1 Occupied Zone The layout and centres of the swirl diffusers must be carefully considered to ensure maximum comfort is achieved. We have provided three alternative arrangements for positioning diffusers, selection methods 1, 2 and 3. Each of the selections will ensure that the maximum terminal velocity in the occupied zone (VH1) will not exceed 0.25m/s, 1.0m below ceiling. 40

Selection Method 1 - Rows 4.0m apart Minimum Diffuser at Centres A Diffuser Rows at Centres 4.0m SECTION 11 Selection Method 2 - Rows 3.0m apart When the diffuser rows are at least 4.0m apart, the minimum diffuser centres should be A. Diffuser Rows at Centres 3.0m Swirl Diffusers Minimum Diffuser at Centres B When the diffuser rows are at least 3.0m apart, the minimum diffuser centres should be B. Selection Method 3 - Rows on Square Grid Diffuser Rows at Centres C Minimum Diffuser at Centres C When the diffuser centres in each direction are equal, the minimum diffuser centres should be C. 41

Swirl Diffusers SECTION 11 Type SDW Square faced adjustable blade swirl diffuser. Type SDW is available in a range of sizes. The removable face plate is held in the plenum box with a centre screw fixing. The head of the screw is covered with a decorative cap. The plenum box is available with side or top entry spigot and a volume control damper. For full details see publication 2/7/EN/... Order Code - Diffuser Type SDW - QS - Z / 500-24 - 600 / 0 / Q21 / P3 / RAL 9010 / 20% Gloss Q = Square flush face Z = Supply A = Extract F = Face Only 2) QL = Square lay in T bar QM15 = Square lay in threadline 15 x 16 QM15 = Square lay in threadline 26 x 16 QS15 = Square lay in threadline 15 x 8 QS26 = Square lay in threadline 26 x 8 QB = Burgess Ceiling Diffuser active size 1) Not used Blank or oversized ceiling module size Number of blades Powder coat finish 0 = Supply air: black air control blades Extract air: no air blades Q11 = Extract air: black air control blades Q21 = Supply air: white air control blades Extract air: white air control blades 1) Note: Standard sizes Q - 300 x 8, 400 x 16, 500 x 24, 600 x 24, 600 x 48, 625 x 24, 625 x 54 QS15-300 x 8 x 600, 400 x 16 x 600, 500 x 24 x 600, 600 x 24 x 600 QB/QL/QS26-300 x 8 x 600, 400 x 16 x 600, 500 x 24 x 600, 600 x 24 x 600, 600 x 48 x 600 QM15/QM26-300 x 8 x 600, 300 x 8 x 750, 400 x 16 x 600, 400 x 16 x 750, 500 x 24 x 600, 500 x 24 x 750, 600 x 24 x 600, 600 x 24 x 750, 600 x 48 x 600, 600 x 48 x 750, 625 x 24 x 750, 625 x 54 x 750 2) Face section without central fixing hole, for use on lay in ceilings QL, QS15, QS26, QM15 & QM26 without rear plenum Order Code - Plenum AK - SDW - ZH - D - MN / 500 x 198 x 24 Plenum Diffuser Diffuser Active Size Spigot 2) Size (mm) Number of blades ZH = Horizontal Spigot (Supply) AH = Horizontal Spigot (Extract) ZV = Vertical Spigot (Supply) AV = Vertical Spigot (Extract) D = Lining or no entry M = Spigot Damper MN = Spigot damper and test point connection1) or no entry 1) Only available on ZH type 2) Refer to product data sheet for spigot sizes available with each plenum size 42

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 100 37 95 30 105 40 120 46 140 65 - - 400 x 16 2, Centres B 75 20 70 18 75 20 85 27 100 47 - - 3, Centres C 25 5 45 7 65 15 85 27 110 43 - - 1, Centres A 140 40 120 27 130 33 140 38 160 50 - - 500 x 24 2, Centres B 100 20 85 14 90 18 100 20 120 27 - - 3, Centres C 35 5 55 9 75 11 100 20 120 27 - - 1, Centres A 150 18 145 17 110 20 180 25 210 35 250 50 600 x 24 2, Centres B 110 10 105 9 110 10 130 14 152 18 180 25 3, Centres C 40 3 65 4 85 6 115 11 170 23 220 38 1, Centres A 190 23 170 18 180 20 195 24 220 30 300 55 600 x 48 2, Centres B 130 11 110 8 120 9 140 13 180 22 200 29 3, Centres C 50 2 80 4 90 6 120 9 180 22 230 33 Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40. SECTION 11 Swirl Diffusers Dimensions Q Size ØD P K 298 x 298 300 x 8 158 250 288 398 x 398 400 x 16 198 295 370 498 x 498 500 x 24 198 295 474 598 x 598 600 x 24 248 345 565 598 x 598 600 x 48 248 345 588 Spigot Lengths Spigot Length Dimension X Spigot Damper Order Suffix Up to 178Ø 198 to 398Ø YES - M - 75mm 100mm NO - 40mm 40mm K I/S PLENUM X K I/S PLENUM 250 P ØD See Type below See Type below 595 face size 16 8 Q Type Q Face-mounted 15 25 Type QL To Lay-on FLAT tee-bar 8 15 584 face size Type QS15 To Lay-on Tegular tee-bar 15mm wide x 8mm deep 15 584 face size Type QM15 To Lay-on Tegular tee-bar 15mm wide x 16mm deep 35 Tile levelled via centre screw i.e. no location pip 16 599 Type QB To Push-In spring tee-bar Suitable for tee or omega type 8 26 584 Type QS26 To Lay-on Tegular tee-bar 26mm wide x 8mm deep 26 573 Type QM26 To Lay-on Tegular tee-bar 26mm wide x 16mm deep 43

Swirl Diffusers SECTION 11 Type VDW Adjustable swirl diffusers type VDW are supplied in a range of sizes. The face plate is circular to suit the architectural requirements The removable face plate is held in the plenum box with a centre screw fixing. The head of the screw is covered with a decorative cap. The plenum box is available with side or top entry spigot, with volume control damper and / or lip seal on request. For full details see publication 2/7/EN/... Order Code Type R = Circular Z = Supply A = Extract V = Top entry plenum H = Side entry plenum VDW - R - Z - V - M - L / 600 x 24 / 0 / 0 / P1 / RAL 9010 / 20% Gloss Size (mm) Not Used Powder coat finish L = Spigot with lip seal M = Volume control damper with adjustable lever 1) MN = Volume control damper with cable and test connection 0 = Supply air: black air control blades Extract air: no air blades Q11 = Extract air: black air control blades Q21 = Supply air: white air control blades Extract air: white air control blades NOTE: 1) Only for supply air with side entry Type VDW-...-V Type VDW-R-...-H ØB ØD K ~32 8 35 H 1 H 2 ØD 40 ØR/Q ØP ØR Type VDW-R-...- ØR 44

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 100 37 95 30 105 40 120 46 140 65 - - 400 x 16 2, Centres B 75 20 70 18 75 20 85 27 100 47 - - 3, Centres C x C 25 5 45 7 65 15 85 27 110 43 - - 1, Centres A 140 40 120 27 130 33 140 38 160 50 - - 500 x 24 2, Centres B 100 20 85 14 90 18 100 20 120 27 - - 3, Centres C x C 35 5 55 9 75 11 100 20 120 27 - - 1, Centres A 150 18 145 17 160 20 180 25 210 35 250 50 600 x 24 2, Centres B 110 10 105 9 110 10 130 14 152 18 180 25 3, Centres C x C 40 3 65 4 85 6 115 11 170 23 220 38 1, Centres A 190 23 170 18 180 20 195 24 220 30 300 55 600 x 48 2, Centres B 130 11 110 8 120 9 140 13 180 22 200 29 3, Centres C x C 50 2 80 4 90 6 120 9 180 22 230 33 Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). SECTION 11 Swirl Diffusers For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted. Dimensions ØR Size B D H 1 H 2 P K 300 300 x 8 280 158 200 250 278 290 400 400 x 16 364 198 200 295 362 372 500 500 x 24 462 198 200 295 460 476 600 600 x 24 559 248 200 345 557 567 600 600 x 48 580 248 300 345 578 590 45

Swirl Diffusers SECTION 11 Type FD Type FD swirl diffusers are available in various sizes. Depending on the architectural requirements, the face plate can be circular or square. The fixed air control blades on the diffuser face are arranged radially. The diffuser face can be attached or removed via a centre fix screw into the plenum box. The screw head is covered with a decorative cap. The plenum box can be supplied with either top or side entry spigots and on request, with spigot lip seals and volume control damper. If a circular diffuser face is ordered, the plenum box with side entry spigot has a 35mm extension piece fitted to the plenum. For full details see publication 2/6/EN/... Order Code Type Q = Square R = Circular Z = Supply A = Extract V = Top entry plenum H = Side entry plenum FD - Q - Z - V - M - L / 400 / 0 / 0 / P1 / RAL 9010 / 20% Gloss Size Not Used Powder coat finish L = Spigot with lip seal M = Volume control damper with single blade 1) MN = Volume control damper with cable and test connection NOTE: 1) Only for side entry spigot Type FD-Q-...-H Type FD-R-...-H Type FD-...-V K K ØB ØD 8 8 35 H 2 ØD H 2 ØD Q ØP ØR ØR/Q R L H 200 40 Type FD-R-...- Type FD-Q-...- fixing screw for diffuser face 46

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 85 65 75 60 80 63 - - - - - - 300 2, Centres B 60 36 54 30 58 33 60 36 70 50 80 63 3, Centres C x C - - 35 13 45 20 58 33 80 63 - - 1, Centres A 125 55 110 40 118 48 120 50 140 65 - - 400 2, Centres B 85 25 78 20 82 23 90 27 100 35 120 50 3, Centres C x C - - 52 9 68 15 80 21 100 35 130 55 1, Centres A 150 40 130 28 135 30 150 40 170 48 - - 500 2, Centres B 105 18 92 14 97 16 105 18 120 23 140 30 3, Centres C x C - - 65 7 85 12 100 17 125 25 155 42 1, Centres A 160 26 145 20 150 21 160 26 185 30 220 45 600 2, Centres B 115 12 100 9 110 11 120 13 135 15 160 25 3, Centres C x C - - 70 5 95 8 115 12 145 20 175 28 Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). SECTION 11 Swirl Diffusers For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted. Max Extract for Noise H = (side entry) V = (top entry) Size Vol Pa Vol Pa 300 65 40 65 65 400 110 40 115 70 500 170 45 140 80 600 200 40 180 55 Selections shown meet NC38 assuming 5dB room attenuation. Note: Vol = Volume l/s Pa = Pressure Drop Dimensions Size Ø B Ø D Ø L Q Ø R H 2 K Ø P 300 280 158 254 298 300 250 290 278 400 364 198 336 398 400 295 372 362 500 462 198 440 498 500 295 476 460 600 559 248 530 598 600 345 567 557 47

Swirl Diffusers SECTION 11 Type DCS Type DCS-P air diffusers consist of the perforated face plate with a thin acoustic fleece lining on the rear. In type DCS-N, the face plate is made of plain sheet steel with perimeter returned edge with central perforated plate insert. The rear swirl diffuser includes a discharge nozzle ring and radially arranged fixed air control blades and connection collar. If required, can be supplied with top entry spigot piece or side entry plenum box with circular spigot. Plenum box can have internal acoustic insulation if specified. For full details see publication 2/4.1/EN/... Order Code Type Face Plate P = Perforated N = Non-perforated C = With discharge nozzle ring V = Visible 1) H = Hidden 2) DCS - P - V - AK / 593 x 315 / 0 / 0 / P1 / RAL 9010 / 20% Gloss Size (mm) 593 1) 598 2) Not Used K = Connecting collar US = Top entry spigot A = Plenum box AK = Plenum box with acoustic insulation Powder coat finish NOTE: 1) For exposed Tee bar fitting...-v (overall face 593) 2) For hidden Tee bar fitting...-h (overall face 598) Type DCS-P-...-K Type DCS-P-...-A/DCS-P-...-AK ØA K 1 K H 2 8 ØC ØB ØR 593 ( 598) H 2 H 1 ØD 8 Type DCS-P-...-US Size...x 125 and...x 160 without perforated plate ØD Type DCS-...-H-US ØC ØB ØR 593 ( 598) 40 8 H 3 Hanging Bracket ØC ØB ØR 593 ( 598) 598 600 48

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A - - 50 65 50 65 - - - - - - 160 2, Centres B 35 31 35 31 38 41 39 43 45 50 50 65 3, Centres C - - 23 14 30 24 40 45 - - - - 1, Centres A 70 50 62 44 62 44 68 45 75 55 - - 200 2, Centres B 42 20 45 24 47 25 51 27 56 29 65 45 3, Centres C - - 32 10 40 17 55 28 70 50 - - 1, Centres A 95 40 78 26 76 25 90 35 - - - - 250 2, Centres B 51 11 54 13 57 18 63 17 70 20 80 27 3, Centres C - - 35 5 47 9 63 17 75 25 100 45 1, Centres A 125 25 105 18 110 20 120 22 140 30 170 45 315 2, Centres B 70 7 75 9 80 11 85 12 100 17 110 20 3, Centres C - - 45 4 65 6 85 12 110 20 140 30 1, Centres A 125 8 115 7 125 8 140 12 155 11 170 16 400 2, Centres B - - - - - - 100 6 115 7 130 9 3, Centres C - - - - - - 100 6 130 9 150 10 Note: Vol = Volume (l/s) Pa = Pressure Drop SECTION 11 Swirl Diffusers Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40. Dimensions Size Ø A Ø B Ø C Ø D H 1 H 2 H 3 K K 1 Ø R...X 160 158 235 210 123 180 79 159 215 237 250...X 200 198 275 250 158 215 79 162 255 277 300...X 250 248 325 300 198 255 76 167 305 327 350...X 315 313 410 385 248 305 89 184 370 392 450...X 400 398 495 470 313 361 89 194 454 476 500 Type DCS-...-V-A / DCS-..-V-AK Type DCS-...-V-K Hanging bracket 593 600 Hanging bracket 593 600 49

Swirl Diffusers SECTION 11 Type TDF TDF - SilentAIR swirl diffusers are available in various sizes. In accordance with architectural requirement the face plate can be circular or square. The fixed air guiding elements of diffuser face are radially arranged. The diffuser can be fastened to the plenum box by means of a central screw and cover cap. The plenum box can be supplied with a horizontal or vertical air connection, or upon request with a volume control damper and / or a sealing lip. For full details see publication 2/6.2/EN/... Order Code Type Silent Air Q = Square R = Circular Z = Supply A = Extract V = Top entry H = Side entry TDF - SA - Q - Z - V - M - L / 400 / 0 / 0 / P1 / RAL 9016 / 20% Gloss Size (mm) 300 400 500 600 Not Used L = Spigot with lip seal Powder coat finish 1) MN = Volume control damper with sheathed cable and measuring nipple M = Volume control with operating rod NOTE: 1) MN only with side entry Type TDF-SilentAIR-R-...-V Type TDF-SilentAIR-Q-...-V R R L ØR ØL ØQ L Central fixing screw for diffuser face Type TDF-SilentAIR-Q-...-H Type TDF-SilentAIR-R-...-H 50

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 80 45 80 45 80 45 80 45 80 45 80 45 300 2, Centres B 62 28 62 28 62 28 62 28 70 38 80 45 3, Centres C 25 5 37 10 48 17 62 28 80 45 80 45 1, Centres A 92 20 92 20 92 20 92 20 100 28 110 33 400 2, Centres B 80 17 80 17 80 17 80 17 100 28 120 37 3, Centres C - - 45 5 65 11 80 17 110 33 135 45 1, Centres A 135 30 135 30 135 30 135 30 140 33 150 38 500 2, Centres B 100 17 100 17 100 17 100 17 120 22 150 38 3, Centres C - - 60 6 80 10 95 14 125 25 165 45 1, Centres A 160 22 160 22 160 22 160 22 165 24 190 30 600 2, Centres B 115 10 115 10 115 10 115 10 135 14 180 27 3, Centres C - - - - 90 7 115 10 145 17 190 30 Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). SECTION 11 Swirl Diffusers For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted. Dimensions Size Ø B Ø D Ø L Q Ø R H 2 K Ø P 300 280 158 254 298 300 250 290 278 400 364 198 336 398 400 295 372 362 500 462 198 440 498 500 295 476 460 600 559 248 530 598 600 345 567 557 625 559 248 530 623 623 345 567 557 Type TDF-SilentAIR-...-V Type TDF-SilentAIR-Q-...-H Type TDF-SilentAIR-R-...-H 40 ØB ØD K ~32 K ~32 8 8 35 200 H 2 ØD H 2 ØD Q/ØR Q ØP ØR 51

Swirl Diffusers SECTION 11 Type TDV The diffuser face of the type SilentAIR offers a high volume flow rate at low sound power levels. The horizontal swirl-type discharge of the supply air ensures high induction and hence rapid reduction in jet velocity and temperature differential. Suitable for supply air temperature differentials up to ±10 K. Depending on requirements, the diffuser can be supplied with a circular or square face and with either white or black air control blades. For the air connection a plenum box is used. The connection can be top or side entry. Face fixing with centre screw and cover cap. For full details see publication 2/7.1/EN/... Order Code Type Silent Air Q = Square R = Circular Z = Supply A = Extract V = Top entry H = Side entry TDV - SA - Q - Z - V - M - L / 400 / 0 / Q21 / P1 / RAL 9010 / 20% Gloss Size (mm) 300 400 500 600 Not Used L = Spigot with lip seal M= Volume control with operating rod 1) MN= Volume control damper with sheathed cable and measuring nipple Powder coat finish Air control blades 0 = Supply air: black Extract air: no Q11 = Extract air: black Q21 = Supply air: white Extract air: white NOTE: 1) Only with side entry Type TDV-SilentAIR-R-...- Type TDV-SilentAIR-Q-...- ØR ØL ØQ ØL Central fixing screw for diffuser face 52

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 80 45 80 45 80 45 80 45 80 45 80 45 300 2, Centres B 65 30 65 30 65 30 65 30 70 37 80 45 3, Centres C - - 40 13 50 19 60 25 75 40 80 45 1, Centres A 120 36 120 36 120 36 120 36 120 36 120 36 400 2, Centres B 85 19 85 19 85 19 85 19 100 27 120 36 3, Centres C - - 50 6 65 12 80 16 110 30 120 36 1, Centres A 150 38 150 38 150 38 150 38 155 39 160 40 500 2, Centres B 100 17 100 17 100 17 100 17 125 25 150 38 3, Centres C - - 65 8 80 10 100 17 140 30 160 40 1, Centres A 170 25 170 25 170 25 170 25 180 28 200 34 600 2, Centres B 120 12 120 12 120 12 120 12 140 16 190 30 3, Centres C - - - - 100 9 120 12 150 18 180 28 Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). SECTION 11 Swirl Diffusers For Selection Methodology see page 40. Dimensions Size Ø B Ø D Ø L Q Ø R H 2 K Ø P 300 280 158 254 298 300 250 290 278 400 364 198 336 398 400 295 372 362 500 462 198 440 498 500 295 476 460 600 559 248 530 598 600 345 567 557 625 559 248 530 623 623 345 567 557 Type TDV-SilentAIR-...-V Type TDV-SilentAIR-Q-...-H Type TDV-SilentAIR-R-...-H 40 ØB ØD K ~32 K ~32 8 8 35 200 H 2 ØD H 2 ØD Q/ØR Q ØP ØR 53

ØA ØD U4 U2 40 ØR2 Q2 8 ØD U6 40 Swirl Diffusers SECTION 11 Type RFD Available in either circular or square face plate, with or without discharge nozzle, to suit architect requirements. Type RFD-...-UO or RFD-...-UD, top entry plenum boxes are inclusive of internal subframe which holds the diffuser in position by central fixing bolt and covering cap. For full details see publication 2/4/EN/... Order Code Type Diffuser Face Q = Square R = Circular D = nozzle K = Connecting ring US = Top entry plenum UD 1) = Top entry plenum with internal subframe (discharge nozzle construction) UC 1) = Top entry plenum with internal subframe (no discharge nozzle) A = plenum box side entry N 1) = Low profile plenum box RFD - Q - D - A - M - L / 200 / 0 / 0 / P1 / RAL 9010 / 20% Gloss NOTE: Size (mm) 125 160 200 250 315 400 Not Used Powder coat finish L= Plenum box with lip seal M = Volume control damper with operating rod 2) MN = Volume control damper with sheathed cable and test nipple 1) Only available with circular construction 2) Not available with N Type RFD-R-D-K Type RFD-Q-D-US Type RFD-R-D-US K 48 32 Type RFD-R-D-UD H4 H1 H3 D ØR2 C Q 1 R 1 8 54

Performance Data Diffuser Centres (m) Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa 1, Centres A 40 70 35 50 35 50 38 60 45 80 50 100 125 2, Centres B 25 28 24 20 27 35 29 38 32 45 38 60 3, Centres C - - 18 15 23 19 29 38 40 70 50 100 1, Centres A 55 55 47 40 47 40 53 50 60 65 70 95 160 2, Centres B 32 18 33 19 35 21 37 27 40 30 47 40 3, Centres C 15 9 24 12 30 16 40 30 55 55 70 95 1, Centres A 67 37 63 34 63 34 68 38 75 45 85 65 200 2, Centres B 43 14 45 15 48 18 50 20 55 24 65 35 3, Centres C - - 30 8 38 9 50 20 68 38 90 70 1, Centres A 110 40 80 23 80 23 100 36 120 50 140 70 250 2, Centres B 52 10 53 11 54 11 55 12 68 15 78 20 3, Centres C - - 35 4 45 7 55 12 60 13 95 32 1, Centres A 115 18 105 15 105 15 110 17 130 25 140 27 315 2, Centres B 72 8 75 8 78 9 80 9 90 11 100 14 3, Centres C - - 45 2 60 5 80 9 105 15 145 29 1, Centres A 130 14 118 11 120 12 140 16 155 18 175 25 400 2, Centres B - - - - 90 7 105 9 120 12 135 15 3, Centres C - - - - - - 100 8 125 13 150 17 SECTION 11 Swirl Diffusers Note: Vol = Volume (l/s) Pa = Pressure Drop Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40. Dimensions Size Ø A Ø C Ø D H1 H3 H4 K Q 1 Q 2 Ø R 1 Ø R 2 U 2 U 4 U 6 125 123 123.5 98 259 195 178 216 198 198 158 200 75 153 192 160 158 158.5 123 284 220 190 266 198 248 197 250 78 158 196 200 198 198.5 158 314 250 202 290 248 248 241 300 78 161 197 250 248 248.5 198 359 295 227 476 298 298 295 350 75 166 202 315 313 313.5 248 409 345 252 567 398 398 364 450 88 183 219 400 398 398.5 313 474 410 285 615 498 498 450 580 88 193 229 55

Jet Nozzles SECTION 12 Type DUK - Standard Supply Jet nozzles type DUK are suitable for almost all situations because of the wide range of variants available. Fixed construction type DUK-F consists of a nozzle with fixing holes. Adjustable construction type DUK-V consists of a spherical discharge nozzle mounted flange and circular spigot for direct connection to a circular duct. The nozzle can be adjusted manually up to max. 30 in any direction. The adjustment can be motorised with an electric or pneumatic actuator. With an actuator the nozzle can only be rotated in one plane up to 30 upwards (cooling) and up to 30 downwards (heating). For full details see publication 1/5/EN/... Order Code DUK - V - K - E1 / 250 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Type P 1) V = Fixed = Adjustable Only with construction V K = Duct connection element A = As K plus spigot R = Duct connection element for circular ducting Size (mm) Not Used Powder coat finish Only with construction V P = With pneumatic actuator E1 = external Rotary actuator 220 V, 50 Hz E2 = external Rotary actuator 24 V, 50 Hz E3 = external Rotary actuator 24 V, 50 Hz, 0...V- E4 = internal linear actuator 220 V, 50 Hz E5 = internal linear actuator 24 V, 50 Hz E6 = internal linear actuator 24 V, 50 Hz, 0...V+ NOTE: 1) Drilled for fixing as standard: extra text required on order if no holes are required. For sizes 100 and 125, construction with actuator not available Performance Data Size Volume (l/s) 13 17 22 28 35 100 Throw L (m) 3.9 4.5 5.8 6.9 9 Rise + Fall (m) 0.6 0.43 0.44 0.5 0.62 Volume (l/s) 17 25 35 45 55 125 Throw L (m) 3.9 5 7 8.5 11 Rise + Fall (m) 0.55 0.5 0.75 0.9 1.3 Volume (l/s) 23 35 50 70 95 160 Throw L (m) 3.5 5.1 7.5 10.5 14 Rise + Fall (m) 0.38 0.3 1.1 1.6 1.8 Volume (l/s) 29 55 85 120 180 200 Throw L (m) 3.8 6.5 10 13 21 Rise + Fall (m) 0.6 1.1 2 3.3 3.4 Volume (l/s) 37 60 95 140 190 250 Throw L (m) 3.8 5.4 8.5 12.5 17.8 Rise + Fall (m) 0.9 1.5 1.6 2.8 3.3 Volume (l/s) 50 100 200 300 400 315 Throw L (m) 3.9 7 13.8 21 28 Rise + Fall (m) 1.3 1.8 3 4.9 9 Volume (l/s) 65 150 250 350 500 400 Throw L (m) 3.9 9 13 18.5 25 Rise + Fall (m) 1.7 2.5 4 4.6 7 Based on horizontal discharge with air temperature ±10k above or below room temperature to a terminal velocity of 0.75 m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation. 56

Dimensions Jet Nozzle Throw L Size D1 D2 D3 D4 D5 E F K L1 L2 L3 100 136 115 146 98 50 10-2 134 94 78 80 125 159 138 169 123 64 10 4 157 112 89 90 160 225 201 200 158 82 11 10 188 122 106 110 200 265 241 257 198 108 16 14 242 153 127 140 250 315 291 302 248 136 16 23 287 187 159 170 315 400 376 384 313 174 23 29 358 224 189 220 400 485 461 467 398 230 24 47 441 287 223 260 rise D d i i di l i l Heating Cooling *For constructions with actuators, L 3 = 365mm irrespective of size. fall Drop and rise is directly proportional to supply air temperature differential. Size Possible Circular Duct Diameters R 200 250 315 500 630 800 100 125 160 200 250 315 400 SECTION 12 Jet Nozzles Type DUK-V-R-E (1-3 shown) Type DUK-V-A-E/DUK-V-K-E (1-3 shown) L 3 * E L 3 * ør Type DUK-V-R Examples of circular duct connection E ød 4 ød 5 ød 3 15 Type DUK-V Type DUK-V-K Examples of rectangular duct connection L 2 DUK V F L 1 9 Counterpunched hole Ø 4.5mm for raised countersunk self-tapping screws 4.2 x 16, DIN 7973 ØD 1 ØD 2 ØD 5 DUK-F Type DUK-F 10 øk 60 ød 3 øk ød 4 60 ød 3 15 Rotary actuator DUK-V-R-E1...E3 (shown) DUK-V-R-P Rotary actuator DUK-V-A-E1...E3 (shown) (shown) DUK-V-K-E1...E3 (shown) DUK-V-K-E1...E3 DUK-V-A-P (shown) DUK-V-K-P DUK-V-A-P DUK-V-K-P 57

Jet Nozzles SECTION 12 Type AJA - Standard Supply Comprises of a Spun Jet Nozzle section mounted in a square face plate with angle flanged border for mounting onto clients duct or plenum. Border supplied undrilled as standard, type CF comes without the square face plate. Jet Nozzle can be adjustable 30 upwards to 30 downwards. The Nozzle mounting plate can also be rotated through 360 which enables the air jets to be fully directional. One, two, three or four elements are available and there are four sizes to choose from. TROX jet nozzle can be installed singularly or in banks. For full details see publication 1/5.1/B/... Order Code Type CF = Circular Face or blank Rear Assemblies A = Without AJA - CF - A / 250 X 2 / 0 / 0 / P3 / RAL 9010 / 20% Gloss Size 200 250 300 350 Not Used Number of elements 1) 1-4 0 = drilled (screwfix) X = undrilled Powder coat finish NOTE: 1) 2, 3 and 4 elements for AJA-A only Order Code AK - AJA - ZV - AG / 250 X 2 / 0 / GO Plenum Nozzle Type ZV = supply nozzle with inline connection AG = Damper or blank Size (mm) 200 250 300 350 Not Used Number of elements 1) 1-4 NOTE: 1) Plenum for CP (circular face) only available for single element units Dimensions Size Nominal Size C L2 L3 L4 Ø A E F W x Z B H 200 350 650 950 1250 200 50 180 310 310 200 200 250 400 750 1100 1450 250 65 195 360 360 250 250 300 450 850 1250 1650 300 75 205 410 410 300 300 350 500 950 1400 1850 350 85 235 460 460 300 350 Heating 30 rise C fall Jet Nozzle Throw L Cooling 30 L 2 L 3 L 4 58 Drop and rise is directly proportional to supply air temperature differential.

Performance Data AJA Volume (l/s) Size 95 140 190 230 280 330 380 420 470 570 660 750 850 940 1040 200 Throw L (m) 8 9 12 15 18 21 Rise + Fall (m) 4.0 5.5 7.0 9.0 10.0 12.0 1 Element 250 Throw L (m) 12 15 17 18 21 24 28 30 Rise + Fall (m) 9.0 10.0 10.5 11.5 13.0 14.0 15.5 17.0 300 Throw L (m) 11 14 15 17 18 21 24 28 34 37 43 Rise + Fall (m) 12.0 12.5 14.5 15.0 16.5 18.0 20.0 22.0 24.0 34.0 43.0 350 Throw L (m) 11 12 14 15 17 20 24 28 30 34 37 Rise + Fall (m) 8.5 12.0 14.0 15.5 17.0 19.0 24.0 29.0 31.0 33.0 35.0 AJA Volume (l/s) Size 95 140 190 230 280 330 380 420 470 570 660 750 850 940 1040 200 Throw L (m) 8 9 11 12 14 15 17 21 24 28 Rise + Fall (m) 5.0 5.5 6.0 6.5 7.5 8.0 9.0 11.0 13.0 16.0 2 Element 250 Throw L (m) 11 12 14 15 18 21 24 28 29 Rise + Fall (m) 7.5 8.0 9.0 10.5 12.0 13.0 14.5 16.0 19.0 300 Throw L (m) 9 11 12 14 15 18 21 24 26 Rise + Fall (m) 7.0 10.0 11.0 12.5 14.5 15.5 18.0 20.0 22.0 350 Throw L (m) 12 14 15 18 20 21 Rise + Fall (m) 19.0 24.0 29.0 31.0 33.0 35.0 SECTION 12 Jet Nozzles AJA Volume (l/s) Size 380 420 470 570 660 750 850 940 1040 1130 1230 1320 1420 1650 1890 200 Throw L (m) 11 12 14 15 17 20 23 24 28 Rise + Fall (m) 6.5 7.0 7.5 8.0 8.5 9.0 10.0 13.0 15.0 3 Element 250 Throw L (m) 12 14 25 17 18 21 23 24 25 28 Rise + Fall (m) 7.5 9.0 9.5 10.0 11.0 12.0 12.5 13.0 14.0 14.5 300 Throw L (m) 11 12 14 15 17 18 20 21 23 24 28 32 Rise + Fall (m) 10.0 10.5 11.0 12.5 13.0 14.0 14.5 15.0 16.0 17.5 19.0 22.0 350 Throw L (m) 12 14 15 17 18 20 21 24 28 Rise + Fall (m) 11.0 13.0 15.0 16.0 17.5 19.0 21.0 23.5 26.0 AJA Volume (l/s) Size 420 470 570 660 750 850 940 1040 1130 1230 1320 1420 1650 1890 200 Throw L (m) 9 11 12 14 15 17 18 21 23 24 26 Rise + Fall (m) 4.5 5.0 5.5 6.5 7.0 7.5 9.0 9.5 10.0 11.0 11.5 4 Element 250 Throw L (m) 11 12 14 15 17 18 18 20 21 24 29 Rise + Fall (m) 6.5 7.0 7.5 8.0 9.0 10.0 10.5 10.0 11.5 13 14.5 300 Throw L (m) 14 15 17 18 20 21 26 Rise + Fall (m) 9.5 10.0 12.0 13.0 15.0 17.0 19.0 350 Throw L (m) 14 15 15 17 18 21 Rise + Fall (m) 13.5 14.0 14.5 15.0 17.0 18.0 Based on horizontal discharge with air temperature ±10K above or below room temperature to average terminal velocity of 0.25m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation. Type AJA Standard type with square face section. Border: for plenum or flanged duct fitting. E F Flange duct section Installation Suspension by others Duct Lockable lever Ø A nom size 60 Conical Adjustment W x Z duct size A Nominal size B x H 30 30 C 450 Side View of Plenum Box Type AJA - PG Shown 59

The art of handling air Design changes reserved. All rights reserved TROX UK Ltd (06/2009) TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 E-Mail: sales@troxuk.co.uk www.troxuk.co.uk