Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

Similar documents
Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

General Cable Support Information

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

Cable Connectors & Conduit Sealing Bushings

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

TCI5125 Dusttight Grip " 1.50"NPT Ins

Cable Connectors & Conduit Sealing Bushings

EPOXY POWDER COATED COPPER FREE ALUMINUM

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

Varnished Cambric Tape 3/4"X60' Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

N0N A 250V One-Time Class H Fuse

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

SW Tog DP 30A 120/277V Autogrd B&S WH

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Taxonomies, Classifications, and Categories MYER'S HUB, 3-PIECE COUPLINGS, THREADLESS COUPLINGS AND THREADLESS CONNECTORS

PGL350P W PS Wallpack

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

TA Ta VA CTRL-XFRMR

Seismic Sensor Accessories SA, SV & ST 6000 Series

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC/NYLON

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Uses, Certifications, and Standards STRUT FITTINGS,BF-FTGS,MISCELLANEOUS

VR A 3W 4P Receptacle. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

24HR 30A SPST TM SW. Features. Long Description

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Wire Mesh Safety Grips

A 120V 20A Gfci RCPT. Features. Dimensions and Weight. Description. Manufacturer Information PASS & SEYMOUR GTIN

5-1/2 INCH L X 4-1/8 INCH W X 6 INCH H

Conduit Bushings for Rigid Metal Conduit and IMC

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

Wire Mesh Safety Grips

GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt

Commercial Products. New Products in the Commercial Products Product Line

Design Standard. Purpose: Design Standard:

CHILL CAST BRONZE WORM GEAR, HARDENED STEEL WORM

G4047BM 2G Gry Cover Plate

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

3/8-Inch Torque Wrench Square Drive, Torque Range Of 30 to 250 Inch Pound (3.39 to NM)

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Description Fan Blade, Size 52 Inch; Dark Oak; Standard Package 5; Craftmade[R] Brand

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

PDX and PX Retrofit Series

PRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

WIREMOLD Pancake Overfloor Raceway

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

AYCL153PHWH 1P/3W CFL/Led Dimmer White

GECAP24400V0 Capacitor For 400W MH BLST

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Circuit Breaker Lockout, Standard And Double Toggles Breaker, Rohs Compliant LOCKOUT,STD AND DOUBLE BREAKER. RoHS Compliant

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

RELB2S40N35I (2)F40T12 120V Ele BLST

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DR20022 Cable Support Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category DR20022 Appleton/Oz Gedney Cable Support, Multiple Segment Plug, Split; Molded Canvas Bakelite Body, Zinc Plated Steel Band, Stainless Steel Bolt/Nut; Tapered Body; Rigid/Imc Conduit; 2 Inch Conduit; Vertical Conduit Position; Non Armored Cable; 5 (Different Size) Conductor(S) 0.8100 (lbs/each) Rigid Conduit Fittings - Steel Features body type TAPERED Cable Type NON ARMORED Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER) conduit position VERTICAL Conduit Size 2 INCH Conduit Type RIGID/IMC Material MOLDED CANVAS BAKELITE BODY, ZINC PLATED STEEL BAND, STAINLESS STEEL BOLT/NUT Number of Conductors 5 (DIFFERENT SIZE) Dimensions and Weight Size Descriptions Commodity Description Long Description Product Type 3-1/4 INCH DIA X 2-1/4 INCH H Flexible Conduit Ftgs, etc. - Liquid Tight Fittings CABLE SUPPORT, MULTIPLE SEGMENT PLUG, SPLIT; MOLDED CANVAS BAKELITE BODY, ZINC PLATED STEEL BAND, STAINLESS STEEL BOLT/NUT; TAPERED BODY; RIGID/IMC CONDUIT; 2 INCH CONDUIT; VERTICAL CONDUIT POSITION; NON ARMORED CABLE; 5 (DIFFERENT SIZE) CONDUCTOR(S) Cable Support

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Manufacturer Information Brand OZ-GEDNEY CO / NEER GTIN 00783126010039 Manufacturers Part Number DR-2002-2 Model DR UPC 783126010039 Taxonomies, Classifications, and Categories Type MULTIPLE SEGMENT PLUG, SPLIT Availability Manufacturer Status Packaging Carton 1 Weight Per each 0.81 Non-Stock Uses, Certifications, and Standards Approval UL 514-B, CSA C22.2

QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which the cables are connected. Properly designed cable supports must not only be capable of supporting a given weight of cable with a good margin of safety but must also support the cable without damaging the insulation or excessively reducing the amount of insulation over the conductor in the area where the cable is supported. O-Z/Gedney has been furnishing to the electrical industry for over 80 years that meet these requirements. Requirements for in the National Electrical Code reads as follows: 300.19 Supporting Conductors in Vertical Raceways. (A) Spacing Intervals - Maximum. Conductors in vertical raceways shall be supported if the vertical rise exceeds the values in Table 300.19(A). One cable support shall be provided at the top of the vertical raceway or as close to the top as practical. Intermediate supports shall be provided as necessary to limit supported conductor lengths to not greater than those specified in Table 300.19(A). QA1 Example: A 10-story building contains a vertical conduit run from the basement to the top floor, approx. 110 feet in length. The raceway contains 4/0 copper conductors. Per Table 300.19(A), the unsupported cable length cannot exceed 80 feet. Therefore, one cable support is required at or near the top of the vertical riser, and one intermediate support is required at or near the midpoint in the conduit run, assuring that any unsupported cable length does not exceed 80 feet. TABLE 300-19(A). Spacing for Conductor Supports Conductors Aluminum or Support of Conductors in Copper-Clad Aluminum Copper Size of Wire Vertical Raceways m ft m ft 18 AWG through 8 AWG Not greater than 30 100 30 100 6 AWG through 1/0 AWG Not greater than 60 200 30 100 2/0 AWG through 4/0 AWG Not greater than 55 180 25 80 over 4/0 AWG - 350 kcmil Not greater than 41 135 18 60 over 350 kcmil - 500 kcmil Not greater than 36 120 15 50 over 500 kcmil - 750 kcmil Not greater than 28 95 12 40 over 750 kcmil Not greater than 26 85 11 35 The chart below indicates the support we recommend for several of the most common applications. Recommended O-Z/Gedney Catalog Application Cable Support Page # TWO or more wires - Indoors - at voltages to 600V Type S QA3 ONE or more wires - Indoors - at all voltages Type R QA5 Retrofit - TWO or more wires - Indoors - at voltages to 600V Type D QA4 Retrofit - ONE or more wires - Indoors - at all voltages Type DR QA6 Ventilating - ONE or more wires - Outdoors - at all voltages Type CMT QA7 Ventilating - Bakelite - ONE or more wires - Outdoors - at all voltages Type V QA8 Non-ventilating - ONE or more wires - Outdoors - at all voltages Type C QA9 Locking - Horizontal/Vertical - ONE or more wires - Indoors - at all voltages Type K QA10 Space Maker - ONE or more wires - Indoors - at all voltages Type M QA11 Pull Box - ONE or more wires - Outdoors at all voltages Type W QA12 Wire Armored Cable - In conduit or supported by structure Type F/FS/FT QA15

QA2 General Information Two basic types of cable supports are offered for use with non-armored cable. They both utilize the pozi-grip Wedging Plug. pozi-grip is a unique manufacturing technique for lining the cable grooves with a coarse grain grit using a high strength epoxy adhesive. This grit improves the Cable Support holding power and does not injure the jacket or insulation on the cable. Other features and their applications are illustrated below. One Piece Plug Type S This type consists of a metal body having an insulating liner with a knurled and tapered inside surface and a one piece impregnated hardwood wedging plug having a groove for each wire. This type support is recommended for use with all types of non-armored cables 600 volts or less, as it is the easiest to install, impossible to install incorrectly and it provides ventilation of the conduit. This design is used in our Types S and D. The basic principles of their assembly are illustrated below. 1 Screw body on the end of the conduit or connector in place of the regular insulating bushing. QA2 Multiple Segment Plug Type R This type consists of an all metal body having a tapered inner surface and a canvas bakelite multiple segment wedging plug so constructed that each cable is supported between grooves in adjacent segments. This construction provides the uniform pressure distribution required by the softer types of insulations frequently used at higher voltages. This design is used in non-ventilating types R, DR, W, C, K and M, and Ventilating Compound Types CMT, and V. The basic principles of their assembly are illustrated below. 1 Screw body on the end of the conduit or connector in place of the regular insulating bushing. 2 Pull wires and arrange temporary means of support. 2 Pull wires and arrange temporary means of support. 3 a. Remove all pulling compound from wires in the area where they pass through the cable support. 3 b. Place the plug between the wires as close to the top of the body as possible. Care should be taken to locate each wire in the proper groove. 4 Tap the plug firmly into the support body. 3 a. Remove all pulling compound from wires in the area where they pass through the cable support. 3 b. Place the segments of the plug around the wires. Where more than two segments are involved the top of each plug segment has numbers at each end and it is important that these are paired with the corresponding numbers on the adjacent plug segments. 4 Tap the plug segments evenly and firmly into the support body.

QA6 Retrofit Type Split Bakelite Body with pozi-grip R-style Wedging Plug Type DR For ONE or more wires already installed in conduit - Indoors - at all voltages. QA6 Use: For supporting non-armored electrical cables in vertical conduit risers. Features: Retrofit Type Cable support can be installed after conductors are pulled and terminated. Split Body rests on existing bushing atop any conduit raceway. Use with all types of insulations at all voltages. The pozi-grip Wedging Plug exerts uniform pressure around the cable, providing holding force in excess of that required by code without deforming cable insulation. Material/Finish: Bodies are two molded Canvas Bakelite halves. Canvas Bakelite pozi-grip Wedging Plug. Steel band zinc plated. Bolts and nuts are stainless steel. Third Party Certification: UL Listed: E-11853 CSA Certified: 11584 Applicable Third Party Standards: UL Standard: 514B CSA Standard C22.2 No. 18 NEC 300-19 Note: Due to the possibility of magnetic induction heating effects, a single alternating current conductor should not be used in these fittings. TO ORDER SPECIFY: 1 Catalog Number 2 Type and number of conductors in conduit 3 Outside diameters of each conductor *Cable support plugs will not be supplied undrilled. *Cable support plugs will not be supplied undrilled. Type DR Catalog Number Complete Fitting Catalog Number Plug Only* Dimensions in Inches Any Number of Any Number of Approx. Inside No. Different Size Different Size Conduit 1-4 Same Wires or 1-4 Same Wires or Outside Overall Turning Dia. of Size Size Wires 5 or More Same Size Wires 5 or More Same Dia. Height Radius Skirt Straps Size Wires Size Wires 1 1 2 DR-1502-1 DR-1502-2 RPLG-1501-1 RPLG-1501-2 2 5 8 2 2 2 1 4 1 2 DR-2002-1 DR-2002-2 RPLG-2001-1 RPLG-2001-2 3 1 4 2 1 4 2 3 8 2 7 8 1 2 1 2 DR-2502-1 DR-2502-2 RPLG-2501-1 RPLG-2501-2 3 7 8 2 1 2 3 3 3 8 2 3 DR-3002-1 DR-3002-2 RPLG-3001-1 RPLG-3001-2 4 1 2 2 7 8 3 1 8 4 2 3 1 2 DR-3502-1 DR-3502-2 RPLG-3501-1 RPLG-3501-2 5 1 4 3 3 8 3 5 8 4 5 8 2 4 DR-4002-1 DR-4002-2 RPLG-4001-1 RPLG-4001-2 5 3 4 3 1 2 3 7 8 5 1 8 2 5 DR-5002-1 DR-5002-2 RPLG-5001-1 RPLG-5001-2 6 3 4 3 3 4 4 3 4 6 1 4 2 6 DR-6002-1 DR-6002-2 RPLG-6001-1 RPLG-6001-2 8 1 4 4 5 8 5 1 4 7 3 8 2 Canvas Bakelite pozi-grip Wedging Plug For one wire type, the plug consists of two pieces. For two wires or more, there is one piece for each wire. Shape and special gripping surface of grooves in plug give maximum support to each cable and distributes even pressure around its entire circumference. Two molded Canvas Bakelite halves. Smooth inside tapered surface assures proper seating of the wedging plug. Steel band, Zinc Plated. Bolts and nuts are Stainless Steel. Existing Bushing Existing Conduit