Reserve Power Systems

Similar documents
Reserve Power Systems

Vented fibre structure Nickel Cadmium batteries for stationary systems

Longlife hybrid solar battery systems with fuel cell technology

Railway Cell Brochure

SegenSolar (Pty) battery storage training

BAE SECURA Product Programme Stationary Batteries ENERGY FROM BATTERIES BAE

Better Efficiency with Electrolyte Circulation

Hoppecke Batteries AHK & GIZ Zambia

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION?

Installation and Operating Instructions. Electrolyte Circulation System

Features and Benefits

Batteries for Renewable Energy Applications

FAT. FAT Battery Range FIAMM.COM

Low maintenance TAB OPzS vented stationary batteries

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

FNC Battery Systems for Rail Vehicles

Valve regulated sealed industrial battery. HAGEN OPzV

trak power premium charge

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

SPA AGM VRLA batteries

Industrial Batteries / Network Power. Classic Energy Bloc.»High performance, long-life energy storage«

BAE Batterien GmbH. Untertitel. TITEL batteries since 1899 made in Berlin. Distribution only by express authority of BAE Batterien GmbH

Tubular Gel Technology For Solar Applications

Industrial Batteries / Network Power. Classic OPzS.»Proven high reliability energy storage for critical applications«

Industrial Batteries / Network Power. Classic OCSM.»Exceptional combination of high power, long life and excellent cycling capability«

RANGE SUMMARY OPzS Optima

SOLAR ENERGY KIT MODEL: SEM-C1HAM7500

Installation, commissioning and operating instructions

Stationary Batteries OPzS Cells

BAE Batterien GmbH TITEL. Batteries since 1899 Made in Germany. Eng. Nader Mansour. Untertitel. Eng. Nader Mansour

Industrial Batteries / Network Power. Sonnenschein A600.»Premium quality for uninterrupted communication«

HOPPECKE Lithium-ion battery systems

Industrial Batteries / Network Power. Classic Solar.»Powerful energy storage for renewable energy systems«

rail systemizer Battery systems for railway applications

PIBAS Ni-Cd cells can be assembled into many different configuration forms, for example:

Batery SERIES. VALVE REGULATED LEAD ACID BATTERies INFINITE POWER. Mission Critical Applications. All Battery Range

Industrial Batteries / Network Power. Classic Solar.»Powerful energy storage for renewable energy systems«

premium charge Innovative charging technology Made in Germany

Industrial Batteries / Network Power. Classic Solar.»Powerful energy storage for renewable energy systems«

Industrial Batteries / Network Power. Classic OGi.»Superior performance for

Deep Cycle AGM Range VRLA

sun systemizer High-performance battery storage for a safe power supply

Tubular Flooded (OPzS) Batteries

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)


CELLYTE 12 PLF & 12PLT Range

HOPPECKE sun powerpack premium

Industrial Batteries - Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications

OPzV Batteries. Technical Data

SSLA. SSLA Battery Range FIAMM.COM

Motive Power (Traction) Batteries & Cells

Industrial Batteries - Classic GroE The proven, reliable energy storage

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

BAE NOVA trans Batteries as motive power

POWER-plus. Ni-Cd XHP. Capacity: 10 Ah to 250 Ah

Industrial Batteries. Classic GroE.»The proven, reliable energy storage«

GEL Technology

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage«

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased ed security«

XHP. Low maintenance high performance batteries

Valve regulated Batteries for Stationary Applications. HAGEN dc plus. An EXIDE Company

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Modular Max AGM Range VRLA

OPzV Batteries for Stationary Applications

PowerSafe OPzV Operation Guide for Solar Applications

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

Industrial Batteries / Network Power

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

SSLA. SSLA Battery Range FIAMM.COM

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased security«

Renewable Energy Storage Solutions

Industrial Batteries Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Dimensional and Electrical Data

Industrial Batteries Network Power Classic OGi Suitable universal energy storage.

2 Volt AGM Range. Haze Battery Company Ltd

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

01 PRONTOFORZ PRONTOFORZ 02

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Industrial Batteries / Network Power. Sonnenschein A700.»The durable high energy and reliable battery system«

General Catalogue VRLA-AGM, VRLA-GEL and Stationary Batteries

Small Traction powerbloc powerbloc dry Hawker XFC TM

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Industrial Batteries Network Power Sonnenschein Solar Safe storage capacity for renewable energy. Specifications

Industrial Batteries Europe Middle East Africa ENGLISH

Reserve Power OPzV Batteries

Small Traction powerbloc powerbloc dry Fiamm Motive Power XFC TM

Reserve Power OPzV Batteries

Applications. EMC tested

Industrial Batteries / Network Power. Sonnenschein SOLAR.»Premium quality for renewable energy«

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

Handbook for Stationary Lead-Acid Batteries Part 1: Basics, Design, Operation Modes and Applications

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

Transcription:

Product Overview Motive Power Systems Reserve Power Systems Special Power Systems Service Your benefits with HOPPECKE standby batteries Highest safety - more than 80 years experience in manufacturing first-class energy storage systems Maximum project flexibility - optimized product range fulfills requirements of various applications German quality standard - equal product quality around the world Comprehensive competence - one source for planning, installation, operation, service and training Individual support - worldwide distribution- and service network Typical applications of HOPPECKE standby batteries IT/Telecom UPS Power Generation Emergency Lighting Signaling systems Engine start Solar Similar to the illustrations

Type range - GroE OSP.HC OSP.XC vented products Short description Standards DIN 40738, IEC 60896-11 IEC 60896-11 IEC 60896-11 Capacity range in Ah 75-2.600*** 105-3.780*** 120-4.140*** Nominal voltage range 2 V 2 V 2 V Container material SAN, clear SAN, clear SAN, clear Grid alloy Positive pure lead Pb + <2% Sb Pb + <2% Sb Negative Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Positive plate Planté Grid Grid Negative plate Grid Grid Grid Electrolyte H 2, liquid Applications Connector design Fully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connector Current behaviour =^ excellent =^ good Design life up to (in years) 25 20 18 Cycles up to Charging voltage in V/cell Float charge 2.23 2.23 2.25 Boost charge 2.40 2.40 2.40 Float charging current/100 Ah nominal capacity (20 C, U float = 2.23/2.25 V/cell) 20-40 ma 20-50 ma 20-50 ma Position independent operation possible No No No Water-refilling intervals in years at trickle charge at 20 C/with AquaGen > 3/extremely extended > 1,5/extremely extended > 1,5/extremely extended Self discharge of nominal capacity at 20 C ambient temperature/per month 3% 3% 3% Operating temperature range in C -20 - +40-20 - +40-20 - +40 Ventilation requirement with AquaGen similar to VRLA with AquaGen similar to VRLA with AquaGen similar to VRLA Storage time at 20 C before refreshing charge (max. 2 recharge intervalls allowed) 3 months 3 months 3 months Type of thread for all types M8 Key: Emergency Power Engine Start Power Plant Power Supply Rail Signal tower Solar

OPzS OPzS solar.power OGi bloc OGi bloc HC DIN 40736-1, IEC 60896-11 IEC 60896-11, IEC 61427 DIN 40739, IEC 60896-11 IEC 60896-11 Design according to DIN 40736-1 200-3.250*** 280-4.700**** 18-256*** 140-364*** 2 V 2 V 4 V, 6 V, 12 V 4 V, 6 V SAN, clear SAN, clear PP, high translucent PP, high translucent Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Pb + <2% Sb Tubular Tubular Grid Grid Grid Grid Grid Grid H 2, liquid Fully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connector 20 15 12 1.500 2.23 2.23 2.23 2.23 2.40 2.40 2.40 2.40 20-50 ma 20-50 ma 20-50 ma 20-50 ma No No No No > 2/extremely extended > 2 > 3/extremely extended > 3/extremely extended 3% 3% 3% 3% -20 - +40-20 - +40-20 - +40-20 - +40 with AquaGen similar to VRLA with AquaGen similar to VRLA with AquaGen similar to VRLA 3 months 3 months 3 months 3 months Switch Gear Telecom Transformer Station UPS * C 1 = Capacity at 1 h discharge ** C 5 = Capacity at 5 h discharge *** C 10 = Capacity at 10 h discharge **** C 100 = Capacity at 100 h discharge

Type range - power.bloc OPzS OPzS bloc solar.power vented products Short description Standards DIN 40737-3, IEC 60896-11 IEC 60896-11, IEC 61427 Design gem. DIN 40737-3 Capacity range in Ah 50-300*** 70-400**** Nominal voltage range 6 V, 12 V 6 V, 12 V Container material PP, high translucent PP, high translucent Grid alloy Positive Pb + <2% Sb Pb + <2% Sb Negative Pb + <2% Sb Pb + <2% Sb Positive plate Tubular Tubular Negative plate Grid Grid Electrolyte H 2, liquid Applications Connector design Fully insulated bolted connector Fully insulated bolted connector Current behaviour =^ excellent =^ good Design life up to (in years) 18 Cycles up to 1.400 Charging voltage in V/cell Float charge 2.23 2.23 Boost charge 2.40 2.40 Float charging current/100 Ah nominal capacity (20 C, U float = 2.23/2.25 V/cell) 20-50 ma 20-50 ma Position independent operation possible No No Water-refilling intervals in years at trickle charge at 20 C/with AquaGen > 3/extremely extended > 3 Self discharge of nominal capacity at 20 C ambient temperature/per month 3% 3% Operating temperature range in C -20 - +40-20 - +40 Ventilation requirement with AquaGen similar to VRLA Storage time at 20 C before refreshing charge (max. 2 recharge intervalls allowed) 3 months 3 months Type of thread for all types M8 Key: Emergency Power Engine Start Power Plant Power Supply Rail Signal tower Solar

FNC FNC VR Li-ion AquaGen premium.top DIN 40763, IEC 60623 DIN 40763, IEC 60623 12-1100** 20-518** 40/50* 1.2 V 1.2 V 25.9 V/37.0 V PP translucent, PP-VO, Grilon PP, PPVO metallized fibre electrode (Ni) metallized fibre electrode (Ni) NMC metallized fibre electrode (Ni) metallized fibre electrode (Ni) Graphit KOH, liquid KOH, liquid Organic Bolted connector Bolted connector Bolted connector Patented technology Advantages of AquaGen premium.top Extends maintenance intervals up to the level of maintenance free No possibility of damage to the battery due to accidental topping up with polluted water Reduction of ventilation requirements Reduced costs for ventilation requirements Reduced explosion risk through integrated arc-back protection No significant escape of gas or of electrolyte fumes 25 25 >15 >2.000 >2.000 1.500-2.500 29.0 V/41.4 V 1.40-1.50 (type depending) 1.40-1.45 1.55-1.60 (type depending) 1.55-1.60 30-180 ma (type depending) 30-180 ma (type depending) at 1.45 V/C, 20 C at 1.45 V/C, 20 C No No Yes >3 (type depending) >10 with AquaGen 1.40 V/Cell: 20 years at 20 C 7% 7% 0,5% -50 - +60-50 - +60-10 - +50 with AquaGen similar to VRLA similar to VRLA None >3 years, see operating instructions >3 years >12 months Switch Gear Telecom Transformer Station UPS Recombination principle in the AquaGen premium.top Gas Watervapour Water * C 1 = Capacity at 1 h discharge ** C 5 = Capacity at 5 h discharge *** C 10 = Capacity at 10 h discharge **** C 100 = Capacity at 100 h discharge

Type range - OPzV OPzV solar.power power.bloc OPzV sealed (VRLA) products Short description Standards DIN 40742, IEC 60896-21/22 IEC 60896-21/22, IEC 61427 DIN 40744, IEC 60896-21/22 Design according to DIN 40742 Capacity range in Ah 200-3.000*** 250-3.500**** 50-300*** Nominal voltage range 2 V 2 V 6 V, 12 V Container material (UL 94-V0 on request) ABS/ABS-V0 ABS/ABS-V0 PP, talcum Grid alloy Positive Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Negative Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Positive plate Tubular Tubular Tubular Negative plate Grid Grid Grid Electrolyte H 2 -Gel H 2 -Gel H 2 -Gel Applications Connector design Fully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connector Current behaviour =^ excellent =^ good Design life up to (in years) 20 15 Cycles up to 1.600 Charging voltage in V/cell Float charge 2.25 2.25 2.25 Boost charge 2.40 2.40 2.40 Float charging current/100 Ah nominal capacity (20 C, U float = 2.25/2.27 V/Cell) 20-50 ma 20-50 ma 20-50 ma Position independent operation possible up to 1500 Ah (optional) up to 1500 Ah (optional) Yes (optional) Water-refilling intervals in years at trickle charge at 20 C/with AquaGen - - - Self discharge of nominal capacity at 20 C ambient temperature/per month 2-3% 2-3% 2-3% Operating temperature range in C -20 - +40-20 - +40-20 - +40 Ventilation requirement VRLA regulation; EN 50272-2 VRLA regulation; EN 50272-2 VRLA regulation; EN 50272-2 Storage time at 20 C before refreshing charge (max. 2 recharge intervalls allowed) 6 months 6 months 6 months Type of thread for all types M8 Key: Emergency Power Engine Start Power Plant Power Supply Rail Signal tower Solar

OPzV bloc solar.power power.com SB/HC/XC net.power solar.bloc IEC 60896-21/22, IEC 61427 IEC 60896-21/22 IEC 60896-21/22, BS 6290-4 IEC 60896-21/22 Design according to DIN 40744 70-370**** 53-604***/45-143***/51-655*** 91-170*** 60-250**** 6 V, 12 V 2 V, 6 V, 12 V/12 V/2 V, 12 V 12 V 6 V, 12 V PP, talcum 2 V: ABS/ABS-V0; 6 V, 12 V: PP, talcum ABS, UL 94-VO PP Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Pb + <1% Ca Tubular Grid Grid Grid Grid Grid Grid Grid H 2 -Gel H 2, AGM H 2, AGM H 2, AGM Fully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connector cramp connector, bolted connector SB: HC/XC: net.power 12 V 92 & 12V 170: 12 15/12/10-12 net.power 12 V 100 & 150: 15 1.300 750 2.25 2.25/2.25/2.27 2.25/2.27 2.25 2.40 2.40 2.40 2.40 20-50 ma 10-40 ma 10-40 ma 10-40 ma Yes (optional) Yes Yes Yes - - - - 2-3% 2-3% 2-3% 2-3% -20 - +40-20 - +40-20 - +40-20 - +40 VRLA regulation; EN 50272-2 VRLA regulation; EN 50272-2 VRLA regulation; EN 50272-2 VRLA regulation; EN 50272-2 6 months 6 months 6 months 6 months Switch Gear Telecom Transformer Station UPS * C 1 = Capacity at 1 h discharge ** C 5 = Capacity at 5 h discharge *** C 10 = Capacity at 10 h discharge **** C 100 = Capacity at 100 h discharge

Motive Power Systems Reserve Power Systems Special Power Systems Service HOPPECKE subsidiaries and factories - European sales and service network Industrial batteries - Complete energy systems - Full Service VRLA batteries in Gel or AGM Types VLA batteries Single cell or block design Battery accessoires Battery management systems and software Batterie/charger servicing Your partner for sustainable energy solutions! Further information on www.hoppecke.com HOPPECKE Batterien GmbH & Co. KG P.O. Box 1140 D-59914 Brilon Bontkirchener Straße 1 D-59929 Brilon-Hoppecke Phone +49(0)2963 61-374 Fax +49(0)2963 61-270 Email info@hoppecke.com www.hoppecke.com Battery recycling Applications engineering and technology Battery room design Technical training and seminars Leasing Power by the hour Reserve Power Systems Produktübersicht EN/05.14/1 K All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.