Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Similar documents
Compact Emergency Light Fittings Series C-LUX 6108 / 6508

7 Lighting Technology

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Sheet Steel Emergency Light Fitting Series 6018

Compact Sheet-Steel Light Fittings Series 6114

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

7 Lighting Technology

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Emergency Light Fitting for Fluorescent Lamps Series 6009

7 Lighting Technology

Sheet-Steel Light Fittings Series 6014 / 6414

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear luminaire with LED Series EXLUX 6002

7 Lighting Technology

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire with LED Series EXLUX 6002

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plug and Socket Devices SolConeX 16 A Series 8570

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Portable Lamps Series HS6145, HSL145

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Safety Switches Series 8537

Terminal Boxes Series 8125

Tank Inspection Lights Series 6122

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Terminal Boxes Series 8125

Floodlight LED Series 6125

Floodlight LED Series 6525

Floodlight LED Series 6525

Ex UPS standard Series 8265

Load disconnect switch Series 8146/5-V11

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Floodlight Series 6521/4

Easy and safe installation

Floodlight Series 6121

10 Load and Motor Switchgear

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Control Buttons / Switches for Panel Mounting Series 8003

Battery Boxes Series 8316

Linear Luminaire for Fluorescent Lamps

Load and Motor Switches, Load-Break Switches Series 8544

EX-REPAIR AND MAINTENANCE RECEPTACLES

Position Switches Series 8074/2

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Control switch/load disconnect switch Series 8008

Load and Motor Switches, Load-Break Switches Series 8544

7 Lighting Technology

Metal Position Switch Series 8074

Position Switches Series 8060/2

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Linear fluorescent luminaire LED V-CG-S

Leading the way in hazardous areas Features EATON

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Position Switches Series 8070/2

Tubular Light Fitting with LED Series 6036

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Load and Motor Switches, Load-Break Switches Series 8549

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Emergency Light Fittings

Control Device System NEC Series ConSig 8040

Operating Instructions

Control Buttons Series 8082

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Linear Luminaire with LED

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

I Ex-safety switches I

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

Transcription:

> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5 > Suitable for wall and ceiling mounting > Can be fitted to order with emergency exit signs > Central locking www.stahl.de 01907E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for safety illumination, but also as information or emergency exit sign lights. ATEX / GOST* Zone 0 1 2 20 21 22 6108: For use in x x x x 6508: For use in x x x *) only 6108 WebCode 6108A Lighting /1

Selection table Version Lamps Emergency light duration test C-LUX 6108 for Zones 1, 2, 21, 22 C-LUX 6508 for Zones 2, 21, 22 Battery capacity Emergency light operation time Order number Weight Ah h kg 1 x 8 W with 2.5 1.5 6108/1081-8017-74-00 3.700 1 x 8 W with 2.5 1.5 6508/1081-8017-74-00 3.900 Order number supplement Cable entries Standard: 1 x Cable gland M25 x 1.5 2 x Plugs M25 x 1.5 Emergency exit sign Special: Specify non-standard entries in writing needed only when used as information lights or escape sign lights; With adhesive symbols positioned as follows: Mounting position Standard 6108/...-..1.-..-.. 6108/...-..9.-..-.. Special please specify other positions in writing Please specify emergency exit sign number (see below) Symbol complying with VGB 125, DIN 4844, DIN 5035; recognition distance e = 30 m; size 150 x 355 mm 08481E00 6108/...-...-..-60 08483E00 6108/...-...-..-61 08482E00 6108/...-...-..-62 08484E00 6108/...-...-..-87 03018E00 6108/...-...-..-91 08485E00 6108/...-...-..-71 03206E00 red 6108/...-...-..-81 12617E00 /2 Lighting

Order number supplement Emergency exit sign 6108/...-...-..-92 08486E00 09020E00 6108/...-...-..-72 12618E00 red 6108/...-...-..-82 6108/...-...-..-90 08487E00 6108/...-...-..-70 03203E00 red 6108/...-...-..-80 12616E00 6108/...-...-..-93 08488E00 12615E00 6108/...-...-..-73 Note 12619E00 red The light fittings are supplied without tubes and mounting material. These accessories must be ordered separately. 6108/...-...-..-83 Explosion protection Europe (ATEX) Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Gas PTB 97 ATEX 2161 ASEV 99.1 10381.01 E II 2 G EEx edm IIC T4 E II 3 G Ex na IIC T4 (Zone 2) Dust LCIE 02 ATEX 6239 SEV 05 ATEX 0125 E II 2 D IP66 T130 C E II 2 D IP66 T75 C Certificates and approvals Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Certificates ATEX, China (CQST), Kazakhstan (GOST-K),Russia (GOST-R), Ukraine (GOST-U), Belarus (GOST-B), Tawain (ITRI) ATEX, China (CQST), Kazakhstan (GOST-K),Russia (GOST-R), Ukraine (GOST-U), Belarus (GOST-B), Tawain (ITRI) Lighting /3

Technical data Electrical data Version 6108 (Zones 1, 2, 21, 22) 6508 (Zones 2, 21, 22) Nominal voltage AC: 220... 254 V, 50... 60 Hz AC: 110... 127 V, 50... 60 Hz possible on request AC: 220... 254 V, 50... 60 Hz AC: 110... 127 V, 50... 60 Hz possible on request Rated current 0.15 A 0.15 A Ballast Electronic ballast, single channel with integral Electronic ballast, single channel with integral emergency light electronics emergency light electronics Disconnection of light fitting on opening Faulty lamp Luminous Characteristics Lamps Light guides Operating modes Central locking device with safety interlock; switch 8080 with N/C contacts; when central lock is opened, voltage to ballast is disconnected on both poles; a safety interlock in switching mechanism prevents fitting from being reconnected while cover and central lock are open. If lamp is faulty power supply is automatically switched off by electronic ballast No switching-off when opening light fitting If lamp is faulty power supply is automatically switched off by electronic ballast 1 x 8 W; two-pin fluorescent lamps, 8 W, d 16 mm, for G5 holder Reflector painted ; Cover with prism structure, providing directed light from the fitting Mains operation for general lighting or as information lights; Emergency operation: fed from battery-set built into emergency lighting fitting when used for escape route illumination or as emergency exit sign lighting. Ambient conditions Charging -5... +50 C Normal mode -20... +50 C Mechanical data Degree of protection IP66 (IP64 with breather 8162) Protection class I(with internal PE connection terminal) Material Enclosure glass fibre reinforced polyester resin, colour:, similar to RAL 9010 Lamp cover Polycarbonate Seal Polyurethane; foamed into cover Cover options Central locking using socket spanner M8 / SW 13; cover hinged for access central lock cover hinge 08478E02 Mounting / installation Cable entry Standard 1 cable entry 8161 in plastic M25 x 1.5 and 2 plugs 8290 in plastic, M25 x 1.5 (enclosed) Graphic 08479E02 Special version Connection Terminal block Marking Terminal size Other entries in moulded plastic or metal are available to order, details available on request in Polyamide with terminal cover L, L, N, PE 2 x 4 mm 2 for solid cores 2 x 2.5 mm 2 for flexible cores /4 Lighting

Technical data Installation notes Looping through of cables 2 leads can be connected to each terminal on the input side, making fittings suitable for looped connection. Mounting Emergency light electronics Design Operating modes Self-test function Functional test Light duration test of the emergency lighting Function indicators Battery charge Emergency light service time Can be wall- or ceiling-mounted 08480E00 Incorporated in one housing with electronic ballast unit Emergency lighting electronics are available: with automatic emergency light duration test; in maintained operation or maintained operation with switchable emergency lighting blocking. The emergency light fitting is available with self-test function. The built-in self-test functions are activated as soon as light is connected to mains and automatically repeated after pre-set time has elapsed. Weekly test of emergency light function; battery and lamp faults are recognized and indicated via red LED. Testing of battery capacity at intervalls of 12 months; operating of fitting in emergency light mode for 2.3rd of rated operating time. If the fitting is switches off by the discharge protection before time has elapsed. Battery cannot be used longer for emergency operation. Fault is indicated via red LED. 1 LED red and 1 LED, incorporated in reflector; can be seen from outside throught cover LED Indication Function Green On Light fitting okay; charging current is supplied Blinking Light fitting okay; function test or continous on test is running Red On Battery error; not connection to the battery or battery completely discharged Blinking Battery error; battery has not enough capacity Flashing 1:10 Lamp error; lamp is out of order or lamp is end of life Green / Red Blinking Flashing Blinking 1 s ON 1 s OFF 0.25 s ON 1.75 s OFF Emergency light function is jam by external switch intelligent battery management system, microprocessor-based (on-load time of max. 14 h) deepdischarging protection to the avoidance of cell pol reversal Battery capacity 2.5 Ah Emergency light operation time 1.5 h / 3.0 h Lighting /5

Technical data Operating modes On delivery light fitting is wired for maintained operation; by removing the jumper between terminals 9 and 10 and connecting external switch F, the fitting is converted to maintained operation with switchable emergency lighting. Terminals emergency lighting electronics Terminals emergency lighting electronics Jumper Maintained operation 08711E02 External switch F 08712E02 Functions Maintained operation On failure of supply to general lighting, fitting is supplied from the battery, irrespective of the light switch position Maintained operation with switchable emergency lighting On failure of power supply to general lighting, fitting switches to emergency lighting operation only if external switch F is closed. To switch emergency lighting centrally to Ready or Not ready, e. g. depending on plant operation times. The external switch has a potential-free NO contact. Note: - line wiring max. 30 emergency light fittings for 1 external switch; - point to point wiring 50 emergency light fittings for 1 external switch - length of cable max. 500 m with wire 1.5mm 2 Maintained operation with switchable emergency lighting Switchover voltage Lighting power in case of emergency light mode Battery set Version Operating voltage Capacity Replacing the battery set Emergency exit signs Use Material Recognition distance Mounting Options from mains to battery operation from battery to mains operation 1.5 h / 70 % 3.0 h / 30 % at U < 0.74 x U N at U > 0.80 x U N NICd battery, gas tight, built into light fitting 6 V 2.5 Ah When the central lock is opened the battery set is de-energized; it can be removed from the housing by unplugging its removable contact. for information and escape sign fittings Foil, self-adhesive, printed with various pictograms in different colours e = 30 m Foil is stuck to cover externally The various types of adhesive foil which can be supplied are detailed in table "Accessories and Spare Parts" Accessories and spare parts Designation Figure Description Art. no. Weight kg Fluorescent lamps 8 W, d 16 mm, for two-pin G5 holder 04936E00 Colour of Light flux light cool 450 Im 10 pcs 119045 0.415 Socket spanner M8 / wrench size 13; to open/close the central locking 140486 0.126 05321E00 /6 Lighting

Accessories and spare parts Designation Figure Description Art. no. Weight kg Adapter plate 05755E00 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 115826 0.060 115828 0.060 Emergency exit sign 1 pc 113182 0.015 08483E00 1 pc 113183 0.015 08482E00 08484E00 1 pc 1 pc 113184 0.015 113206 0.015 03018E00 1 pc 113210 0.015 08485E00 1 pc 113193 0.015 03206E00 red 1 pc 113200 0.015 12617E00 08486E00 1 pc 113211 0.015 1 pc 113194 0.015 09020E00 red 1 pc 113201 0.015 12618E00 08487E00 1 pc 113209 0.015 1 pc 113192 0.015 03203E00 red 1 pc 113199 0.015 12616E00 1 pc 113212 0.015 08488E00 1 pc 113195 0.015 12615E00 red 1 pc 113202 0.015 12619E00 Lighting /7

Accessories and spare parts Designation Figure Description Art. no. Weight kg Diffuser for light fitting 8 W 119044 0.250 05704E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 181 a 4 9 R3,5 425 11 7 Additional dimensions for cable entries 8161 and plugs 8290 a (mm) 8161 M25 x 1.5 32 8290 M25 x 1.5 6 445 150 119 355 04293E00 Emergency exit sign 04295E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /8 Lighting