Ventilation in balance

Similar documents
Ventilation in balance

Modbus Integration Integration for Modbus Functionality for VT8600 Series

STRA-24 for chilled beams

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Hamilton 3VO Submittal

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION

Regulation HRmural. Installation and user s manual

ECONET PREMIUM START UP ON SITE ROUTINE FOR ECONET START UP: THE ECONET SYSTEM SHALL BE STARTED UP BY AUTHORIZED PERSONEL PROTOCOL BEFORE START UP

GLOBAL PX/RX/LP. Operation and maintenance instructions GLOBAL PX GLOBAL RX GLOBAL LP FW GLOBAL PX FW GLOBAL PX TOP

BACnet MS/TP Networking Flow Balancing Control Valves

AIR VOLUME TRANSMITTER / CONTROLLER IML

Horizon Troubleshooting Flowchart

Fault Codes. J control

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Vission 20/20 micro-controller. Operation and service manual

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

PCT-3001 plus. Display LCD

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

CH5000 Heat Recovery Ventilator

AC drive has detected too high a Check loading

Appendix A: Inputs, Outputs, and Parameters

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

INSTALLATION CONNECTIONS. COMMUNICATION. COMMISSIONING AM ; AMC 150; DV 1000

ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Vission 20/20 micro-controller. Operation and service manual Version 2.6

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Ion Technologies SUMPRO Battery Back-Up

9.1.4 Troubleshooting of Faults in LCD Screen

Module 4: Climate Control

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

An ISO 9001:2008 Registered Company

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Operations Manual OM

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

Service instructions. MAGNA Series 2000

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

SmartPak Welding Controller WK-MPS-16 Constant Current

DESCRIPTION AND OPERATION

BACnet PTEC Controller VAV Chilled Beam with Demand Control Ventilation (CO2) and Floating or Analog Output Owner s Manual

Tanktronic Installation Guide

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

SMT-150 Installer Manual

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

PJC321, PJC322 PJC321-L, PJC322-L PJC321-MCL2, PJC322-MCL2 S-link Control Panel

SPECIFICATION SHEET. C5000 ( cfm)

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

FKP-R/R2. User Guide for Pressure and Temperature controller with integrated pressure sensor

HWS Heater (alternative) Electric Heater Stage 2 IQLVAV Electric Heater Stage 1. , P Serial Fan on/off SUPPLY AIR. Parallel Fan

SNMP dedicated to ORVALDI Solar Infini

SE7200 Series Installation Guide

RVD125/109 RVD145/109

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

USERS MANUAL MCD REMOTE OPERATOR

DESCRIPTION AND OPERATION

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Modulating Furnace Information. Warning on Meter Setting - Read First!

MicroTech II Applied Rooftop Unit Controller

Delomatic 400 GAS CHP controller TCP/IP Modbus communication

ECON-ZIP-DETF; ZIP PACK

MC200CAB/4 Integral Version

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Note: If anything is damaged or missing, contact your customer representative immediately.

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

BACnet PTEC Controller Dual Duct Two Air Velocity Sensors. Owner's Manual Building Technologies

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

RECU-NOVO. heat recovery unit

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Variable speed application guidelines

DCC-3000 Climate Control for Vintage Air GEN-IV systems

Description. functions including single duct pressure dependent or pressure independent systems.

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

CX-SERIES ADVANCED BATTERY CHARGER

Models: 12 and 18. Models: 24 to 60

2015 F-250, 350, 450, 550 Super Duty DESCRIPTION AND OPERATION Procedure revision date: 04/28/2016. Climate Control System

TRW Commercial Steering Torque Overlay Diagnostic Tool

Application Engineering Europe

Transcription:

Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR BACNET TM /IP. BACNET TM MS/TP

BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware version is specified at index. BACnet TM /IP: Unit IP address, gateway, DHCP settings etc. can be changed by using the configuration software that is available at Airmaster's website. BACnet TM MS/TP: Unit address and baud rate can be changed via index 28 and 29 or by using Airlinq Service Tool that is available at Airmaster's website. BACNETCOMMUNICATION 28 Bacnet ms/tp addr. BACnet MS/TP address. 27 29 Bacnet ms/tp baud. BACnet MS/TP baud rate. 3 Multi-State = 96 = 92 2 = 384 3 = 768 BASIC CONTROL SETTINGS 22 D-BMS auto vent. Activate Automatic Operation at this input. = No / Stop This parameter is typically used to start/stop the air handling unit from the BMS. = Yes / Start N.B.: Index 3, 8-2. 25 D-BMS airflow % Setpoint for desired airflow in case the unit is started by the BMS (index 22). % 26 D-BMS temperature Setpoint for desired inlet temperature in case the unit is started by the BMS (index 22). Please consult the maunal for recommendations. C 8 4 9, PPM - 5 For further information please consult the manual. nimum and maximum (index 9 and ). 23 D-BMS nightcool Activate this input to request night cooling. = No Night cooling will only run when setpoint temperatures are exceeded during the day. The limits are adjustable = Yes via Nightcool high and low limit (index 7 and 8). For further information please consult the manual. 24 D-BMS Holiday mode Activate holiday mode operation at this input. = No = Yes 8 D-BMS Start by PIR PIR sensor is optional. = No In case the unit has a PIR sensor connected directly, is it allowed to start by it, or shall it only pass on the signal = Yes to the BMS system. When the unit is started by a local PIR sensor, index 33 and 34 are used as setpoints for airflow and inlet temperature. = No = Yes airflow and inlet temperature. 2 D-BMS use timer Is the unit allowed to start by the build in timer. The timer settings are not available via BMS, only the = No possibility to enable/disable the timer are available to BMS. = Yes 2 D-BMS Panel start Control panel is optional. = No In case the unit has a local control panel connected, is it allowed to start by it. When the unit is started by a = Yes local control panel, index 33 and 34 are used as setpoints for airflow and inlet temperature. 3 Allow Ext. Start In case the unit has an External Start Signal connected directly, is it allowed to start by it, or shall it only pass = No on the signal to the BMS system. When the unit is started by a local external start signal, index 33 and 34 are = Yes used as setpoints for airflow and inlet temperature. 2

ADVANCED CONTROL SETTINGS (index 3, 8, 9, 2). 34 Default Temperature Setpoint for desired inlet temperature in ca local 2 PIR afterrun external start (index 3, 8, 9, 2). Please consult the maunal for recommendations. Setpoint for the PIR afterrun time, local connected PIR only. High Roomtemp. Setpoint for the limit that causes the unit to enter "High Room Temperature" operation mode. 7 8 5 6 4 7 4 Low Roomtemp. Nightcool High Nightcool Low Nightcool IT Nightcool Flow d_ah_min_c d_ah_max_c Reboot Consult the manual for further description of the "High Room Temperature" operation mode. Setpoint for the limit that causes the unit to exit "High Room Temperature" operation mode. Consult the manual for further description of the "High Room Temperature" operation mode. Setpoint for Night Cooling High Limit, Consult the "Night Cooling" section in the manual for further description. Setpoint for Night Cooling Low Limit, Consult the "Night Cooling" section in the manual for further description. Inlet Temperature setpoint when running in Night Cooling mode, started from BMS (index 23). Airflow setpoint when running in Night Cooling mode, started from BMS (index 23). Coefficient for absolute humidty calculation. Coefficient for absolute humidty calculation. Activate this input to reboot the controller by setting the value to. The value will automatically return to. start % 8 C 8 3 9 min 8 3 PPM 4 5 5 5 PPM 4 5 9 5 C 5 25 C 5 24 C 3 26 C 3 23 C % -99,99-99,99 3 99,99 99,99 6,, sensor. The default value is 5 min if the air handling unit is supplied with a The default value is 3,6 if the air handling unit is supplied with electronic humidity sensors. The default value is 6, if the air handling unit is supplied with electronic humidity sensors. = No = Yes SENSOR SIGNALS 24 23 PIR Output Manuel Start N.B.: D-BMS CO2 PPM (index 27). N.B.: D-BMS Start by CO2 (index 9). Motion sensor (PIR) is optional. The PIR signal includes the afterrun time (index 2). In case a PIR signal without afterrun time is preferred, set the afterrun time to. N.B.: D-BMS Start by PIR (index 8). Indicates if the hardware input "External Start" is activated or not. N.B.: Allow Ext. Start (index 3). PPM 5 = Off = On = Off = On 3

SENSOR SIGNALS Room Temperature Room temperature, measured in the extraction air. C, 2 Inlet Temperature Inlet Temperature, measured at the inlet opening. C, 7 Outside Temp. Vent. Outside Temperature, measured at the air handling unit. C, 8 Exhaust Temp. Vent. Exhaust temperature, measured at the air handling unit, near the heat exchanger. C, 3 Outside Temperature Cooling module is optional. Outside temperature, measured at the cooling module. 6 Condenser Temp. Used for both ON/OFF and inverter controlled cooling modules. ON/OFF controlled cooling module is optional. Condenser Temperature. The Condenser is a part of the cooling module. 5 Evaporator Temp. ON/OFF controlled cooling module is optional. Evaporator Temperature. The Evaporator is a part of the cooling module. 36 Evaporator In Temp. Inverter controlled cooling module is optional. Evaporator temperature, inlet. The evaporator is a part of the comfort cooling unit. 37 Evaporator Out Temp. Inverter controlled cooling module is optional. 38 8 Hotgas Temperature Rel. Hum Supply Evaporator temperature, outlet. The evaporator is a part of the comfort cooling unit. Inverter controlled cooling module is optional. Humidity sensor is optional: Humidity measured in the supply air. 9 Rel. Hum Extraction Humidity sensor is optional: Humidity measured in the extraction air. 4 Supply Flow # + #2 Flow measurement is optional. 5 3 34 Extraction Flow Tot. Power (Wh) Cool Unit Power Measured supply airflow. Flow measurement is optional. Measured extraction airflow. Energy meter is optional. The energy meter measure the energy consumption of the air handling unit. Energy meter and cooling module are optional. The energy meter measure the energy consumption of the cooling module. C, C, C, C, C, C, % % Wh 4294967295 Wh 4294967295 SYSTEM INFORMATION 2 System Mode This output indicates the system operating mode for the air handling unit. 6 Requested Temp. The actual inlet temperature setpoint may vary from requested value, thus the actual setpoint is available here. 255 Multi-State C, 7 Requested Flow The actual air flow setpoint may vary from requested value, thus the actual setpoint is available here, e.g. due % 3 Pre Heater % Preheaing suface is optional. Percentage heat output relative to maximum. Comfort Heater % Comfort heaing surface is optional. Percentage heat output relative to maximum. % % = Stopped = Starting 2 = Auto / Running 3 = Stopping 4 = Filter Test Running 5 = Filter Calibration 6 = Night Cooling 7 = Holiday Mode 8 = Manual Mode 4

SYSTEM INFORMATION 2 Cooling % Comfort cooling module is optional. Percentage cooling output relative to maximum. Bypass Damper % Bypass damper is optional. Percentage bypass position relative to maximum. % % 2 System Condition This output indicates the system condition for the air handling unit. -32768 32767 22 System Alarm This output indicates system alarms for the air handling unit. -32768 32767 33 Hardware errors This output indicates the hardware status of the the air handling unit and cooling module. 4294967295 = full heat recovery N.B.: Convert to binary representation Bit = [Low Temp Process Inactive Active] Bit = [High Temp Process Inactive Active] Bit 2 = [Condensation Process Inactive Active] Bit 3 = [Non Critical Hardware Fault False True] Bit 4 = [Condenser Overheated False True] Bit 5 = [Compressor Locked False True] Bit 6 = [Filter Change Needed False True] Bit 7 = [High Room Temp False True] Bit 8 = [Abnormal Filter Test Calibration Result False True] Bit 9 = [Manual Override Active False True] Bit = [Comfort Cool Defrost Warning False True] Bit = [Comfort Cool Condensation Warning False True] Bit 2 = [Boost Mode Active False True] Bit 3 = [Comfort Cool Hotgas Warning False True] Bit 4 = [Comfort Cool Pressure Warning False True] Bit 5 = [Group Master Not Available Warning False True] N.B.: Convert to binary representation Bit = [Low Temp Alarm False True] Bit = [Condensation Alarm False True] Bit 2 = [Filter Alarm False True] Bit 3 = [Critical Hardware Fault False True] N.B.: Convert to binary representation Bit = [Room Temperaturesensor OK Fault] Bit = [Inlet Temperaturesensor OK Fault] Bit 2 = [Outside Temperaturesensor OK Fault] Bit 3 = [General Purpose Temperaturesensor OK Fault] Bit 4 = [Condenser Temperaturesensor OK Fault] Bit 5 = [Evaporator Temperaturesensor OK Fault] Bit 6 = [Exhaust Temperaturesensor Ventilation Unit OK Fault] Bit 7 = [Outside Temperaturesensor Ventilation Unit OK Fault] Bit 8 = [Supplyflow Sensor OK Fault] Bit 9 = [Supplyflow Sensor 2 OK Fault] Bit = [Extractionflow Sensor OK Fault] Bit = [CO2 Sensor OK Fault] Bit 2 = [Supply Fan OK Fault] Bit 3 = [Extraction Fan OK Fault] Bit 4 = [Evaporator In Temperaturesensor OK Fault] Bit 5 = [Evaporator Out Temperaturesensor OK Fault] Bit 6 = [Hotgas Temperaturesensor OK Fault] Bit 7 = [Comfort Cooling Connection Lost OK Fault] Bit 8 = [Comfort Cooling Stepdriver OK Fault] Bit 9 = [Comfort Cooling Frequency Inverter OK Fault] Bit 2 = [Humidity Supply Air Sensor OK Fault] Bit 2 = [Humidity Extraction Air Sensor OK Fault] Bit 22 = [Humidity Sensor Settings OK Fault] Firmware version Software version installed in the air handling unit. 32 6, 5

LOCAL CONTROL PANEL 35 Panel Flow Request Local control panel is optional. % = no request from user Flow percent requested by the user via a local control panel. N.B.: Panel Flow Function (index 3). 3 Panel Flow Function This value defines how the air handling unit respond to a change of the airflow setpoint by the user via a local 2 Multi-State = Direct control panel. "Direct": The airflow setpoint can temporarily be overridden from a local control panel. "None": The airflow setpoint can not be overridden from a local control panel. "D-BMS": A change of the airflow setpoint from a local control panel will be shown at index 35, but will not affect the actual flow setpoint directly. N.B.: Manual Override Time (index 35). = None 2 = D-BMS 35 Manual Override Time This value defines for how long time an override of the airflow setpoint from a local control panel will be stored in the controller. hour(s) 8 2 SERVICE AND FILTER INFORMATION 29 Filter remain. days Estimated remaining service life of the filters in days calculated by the average daily operating hours since last service. days 32 Remain Serv. Life H Remaining service life of filters in operating hours. hour(s) 65535 3 Remain Serv. Life % Estimated remaining service life of filters in %. 32 Reset Filter Status The filter monitoring must be reset after a filter change. Set the value to to reset filter status. 36 Filter Test Mode The value will automatically return to when filter status has been reset. This parameter defines the filter test mode. "Timer": Filter monitoring using an hour counter. "Tacho": Electronic flow monitoring. "Timer and tacho": Filter monitoring using an hour counter and electronic flow monitoring. 37 Life Span Warning This value defines the operating hours before activating a filter warning at index 2. hour(s) 876 5 38 Life Span Alarm This value defines the operating hours before activating a filter alarm at index 22. hour(s) 876 2 39 Filter Max Life Time This value defines the maximum filter life time and for how many months the air handling unit can operate after a service reset before activating a filter alarm (index 22). The max life time alarm can be disabled by setting the value to. 4 Filter Warn. Period This value defines the period for a filter warning at index 2 before the filter alarm activates. By using the default value of this parameter the filter warning at index 2 is activated 2 months before the maximum filter life time expires (index 39). 3 Run Filter Calib. Set the value to to run a filter calibration. The value will automatically return to when the calibration process has finished. N.B.: Do only run a filter calibration with clean filters. N.B.: Do only run a filter calibration at the first start of an air handling unit with AQC-P control box by non standard installation e.g. on reduction of the duct size, when using more than m of duct or when installing with elbows. N.B.: A new filter calibration shall be performed if the filter class is changed (from M5 to F7 etc.) during a service routine of the air handling unit with AQC-P control box. % 3 3 Multi-State month(s) 48 4 month(s) 2 2 = filter change required = clean filters = No = Yes = Off = Timer (default for air handling units with AQC-L) 2 = Tacho 3 = Timer And Tacho (default for air handling units with AQC-P) The default value is 4 h for CV and DV product series. The default value is 5 h for CV and DV product series. = No = Yes 6

Notes: 7

Industrivej 59 DK - 96 Aars Denmark Tel: +45 98 62 48 22 Fax: +45 98 62 57 77 info@airmaster.dk www.airmaster-as.com Version: BACnet TM /IP, BACnet TM MS/TP - 25--27