Ventilation in balance

Similar documents
Ventilation in balance

Modbus Integration Integration for Modbus Functionality for VT8600 Series

AIR VOLUME TRANSMITTER / CONTROLLER IML

STRA-24 for chilled beams

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

Regulation HRmural. Installation and user s manual

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION

Modbus Register Map:Galaxy VM (3: kVA 400/480V)

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

RVD125/109 RVD145/109

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

PCT-3001 plus. Display LCD

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

FKP-R/R2. User Guide for Pressure and Temperature controller with integrated pressure sensor

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Fault Codes. J control

USERS MANUAL MCD REMOTE OPERATOR

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

Ion Technologies SUMPRO Battery Back-Up

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

AC drive has detected too high a Check loading

Application Engineering Europe

Vission 20/20 micro-controller. Operation and service manual Version 2.6

Horizon Troubleshooting Flowchart

Vission 20/20 micro-controller. Operation and service manual

ECONET PREMIUM START UP ON SITE ROUTINE FOR ECONET START UP: THE ECONET SYSTEM SHALL BE STARTED UP BY AUTHORIZED PERSONEL PROTOCOL BEFORE START UP

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

GLOBAL PX/RX/LP. Operation and maintenance instructions GLOBAL PX GLOBAL RX GLOBAL LP FW GLOBAL PX FW GLOBAL PX TOP

MATRIX LLC LEVEL CONTROL PANEL

1 Communication format Inquiry Command... 1

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

SmartPak Welding Controller WK-MPS-16 Constant Current

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

Hamilton 3VO Submittal

EV Display V4 User Guide

9.1.4 Troubleshooting of Faults in LCD Screen

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

SMT-150 Installer Manual

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

Operations Manual OM

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

PQube 3 Modbus Interface

HWS Heater (alternative) Electric Heater Stage 2 IQLVAV Electric Heater Stage 1. , P Serial Fan on/off SUPPLY AIR. Parallel Fan

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

Installation Manual. ACL3200 Flare Stack / Incinerator Ignition Systems

X11CA-IM MASTER MODULE

Installation, Service, and Troubleshooting Instructions

RKE RKE FO RKE BF RHR SRS Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

Description. functions including single duct pressure dependent or pressure independent systems.

Tanktronic Installation Guide

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

VisionPRO 8000 Thermostats

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

BMS Information SOLA-BOOST Classic & SOLA-BOOST X-Air

OPERATING INSTRUCTIONS ECON-M

Module 4: Climate Control

MaxxForce DT, 9, 10 ( )

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

A I R C O M P R E S S O R S R O L L A I R E

LT2 Sport Lambda Measurement Device. Quick Start Manual

Generator auto start/stop on CCGX and Venus GX

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Accessories. Series REC

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Appendix A: Inputs, Outputs, and Parameters

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

RECU-NOVO. heat recovery unit

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Fisher D4 Control Valve with Gen 2 easy-drive Electric Actuator

U n i n t e r r u p t i b l e P o w e r S y s t e m

Modulating Furnace Information. Warning on Meter Setting - Read First!

Overvoltage Suppression F7 Drive Software Technical Manual

MC200CAB/4 Integral Version

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Transcription:

Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485

BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware version is specified at register 43. MODBUS Data Model: Holding Registers Function Code: 3 Read Holding Registers Transmission Mode: RTU, RS-485 Register Formats: Signed 6-bit Integer MODBUS COMMUNICATION 4 Modbus Address Setpoint for the Modbus address. 247 3 X N.B.: Any change of the current parameter requires a reboot (register 457). 42 Modbus baud Setpoint for the Modbus baud rate. 5 X = 96 N.B.: Any change of the current parameter requires a reboot (register 457). = 92 2 = 384 3 = 576 4 = 52 5 = 234 43 Modbus Parity Setpoint for the Modbus parity mode. 2 2 X = None (2 Stop bits) N.B.: Any change of the current parameter requires a reboot (register 457). = Odd ( Stop bit) 2 = Even ( Stop bit) BASIC CONTROL SETTINGS 44 Automatic Operation: Start Activate Automatic Operation at this input. X = No / Stop This parameter is typically used to start/stop the air handling unit from the BMS. = Yes / Start N.B.: Register 442-446. 45 Automatic Operation: Flow setpoint Setpoint for desired airflow in case the unit is started by the BMS (register 44). % X 46 Automatic Operaion: IT setpoint Setpoint for desired inlet temperature in case the unit is started by the BMS (register 44). Please consult the maunal for recommendations. the unit. C 8 4 9 X PPM - 5 X For further information please consult the manual. 48 Night Cooling: Start Activate this input to request night cooling. X = No Night cooling will only run when setpoint temperatures are exceeded during the day. The limits are adjustable = Yes via Night Cooling: high and low limit (register 454 and 455). For further information please consult the manual. 49 Holiday Mode Operation: Start Activate holiday mode operation at this input. X = No = Yes 2

BASIC CONTROL SETTINGS 442 Allow Start by Local PIR PIR sensor is optional. X = No In case the unit has a PIR sensor connected directly, is it allowed to start by it, or shall it only pass on the signal to the BMS system. When the unit is started by a local PIR sensor, register 472 and 473 are used as setpoints for airflow and inlet temperature. = Yes X = No = Yes setpoints for airflow and inlet temperature. 444 Allow Start by Local Timer Is the unit allowed to start by the build in timer. The timer settings are not available via BMS, only the possibility X = No to enable/disable the timer are available to BMS. = Yes 445 Allow Start by Local Panel Control panel is optional. X = No In case the unit has a local control panel connected, is it allowed to start by it. When the unit is started by a local = Yes control panel, register 472 and 473 are used as setpoints for airflow and inlet temperature. 446 Allow Start by Local External Start In case the unit has an External Start Signal connected directly, is it allowed to start by it, or shall it only pass on X = No the signal to the BMS system. When the unit is started by a local external start signal, register 472 and = Yes 473 are used as setpoints for airflow and inlet temperature. ADVANCED CONTROL SETTINGS al start (register 442, 443, 445, 446). sensor. r local C 8 3 9 X external start (register 442, 443, 445, 446). Please consult the maunal for recommendations. 449 PIR Afterrun Time Setpoint for the PIR afterrun time, local connected PIR only. min 8 3 X The default value is 5 min sensor. PPM 4 5 5 X PPM 4 5 9 X 447 High Room Temperature, High limit Setpoint for the limit that causes the unit to enter "High Room Temperature" operation mode. C 5 25 X Consult the manual for further description of the "High Room Temperature" operation mode. 448 High Room Temperature, Low limit Setpoint for the limit that causes the unit to exit "High Room Temperature" operation mode. C 5 24 X Consult the manual for further description of the "High Room Temperature" operation mode. 454 Night Cooling: High limit Setpoint for Night Cooling High Limit, C 3 26 X Consult the "Night Cooling" section in the manual for further description. 455 Night Cooling: Low limit Setpoint for Night Cooling Low Limit, C 3 23 X Consult the "Night Cooling" section in the manual for further description. 456 Night Cooling: IT setpoint Inlet Temperature setpoint when running in Night Cooling mode, started from BMS (register 48). C 3 6 X 458 Night Cooling: Flow setpoint Airflow setpoint when running in Night Cooling mode, started from BMS (register 48). % X 46 Absolute humidity Min. C Coefficient 464 Absolute humidity Max. C Coefficient 457 Reboot C oefficient for absolute humidty calculation. -99,99 99,99 X The default value is 3,6 if the air handling unit is supplied with electronic humidity sensors. C oefficient for absolute humidty calculation. -99,99 99,99 X The default value is 6, if the air handling unit is supplied with electronic humidity sensors. Activate this input to reboot the controller by setting the value to. X = No The value will automatically return to. = Yes 3

SENSOR SIGNALS PPM 5 X 45 PIR output Motion sensor (PIR) is optional. The PIR signal includes the afterrun time (register 449). X = Off In case a PIR signal without afterrun time is preferred, set the afterrun time to. = On N.B.: Allow start by local PIR (register 442). 46 External Start output Indicates if the hardware input "External Start" is activated or not. X = Off N.B.: Allow start by External Start (register 446). = On 47 Room Temperature Room temperature, measured in the extraction air. C X 48 Inlet Temperature Inlet Temperature, measured at the inlet opening. C X 423 Outside Temperature at Ventilation Unit 424 Exhaust Temperature at Ventilation Unit Outside Temperature, measured at the air handling unit. Exhaust temperature, measured at the air handling unit, near the heat exchanger. 49 Outside Temperature Cooling module is optional. Outside temperature, measured at the cooling module. Used for both ON/OFF and inverter controlled cooling modules. 42 Condenser Temperature ON/OFF controlled cooling module is optional. Condenser Temperature. The Condenser is a part of the cooling module. 422 Evaporator Temperature ON/OFF controlled cooling module is optional. Evaporator Temperature. The Evaporator is a part of the cooling module. 484 Evaporator In Temperature Inverter controlled cooling module is optional. Evaporator temperature, inlet. The evaporator is a part of the comfort cooling unit. 485 Evaporator Out Temperature Inverter controlled cooling module is optional. 486 Hotgas Temperature Evaporator temperature, outlet. The evaporator is a part of the comfort cooling unit. Inverter controlled cooling module is optional. C X C X C X C X C X C X C X C X 425 Relative Humidity, outside Humidity sensor is optional. Humidity measured in the supply air. 426 Relative Humidity, inside Humidity sensor is optional. 436 437 Supply Flow Extraction Flow Humidity measured in the extraction air. Flow measurement is optional. Measured supply airflow. Flow measurement is optional. Measured extraction airflow. 44 Airhandling Unit Energy Meter Energy meter is optional. The energy meter measure the energy consumption of the air handling unit. N.B.: decimal points are available in a seperate value (register 44). 44 Airhandling Unit Energy Meter Energy meter is optional. decimal points The decimal values of the air handling unit energy consumption. 48 Cooling Unit Power Consumption Energy meter and cooling module are optional. The energy meter measure the energy consumption of the cooling module. N.B.: decimal points are available in a seperate value (register 48). 48 Cooling Unit Power Consumption Energy meter and cooling module are optional. decimal points The decimal values of the cooling module energy consumption. % X % X kwh 32767 X kwh,999 X kwh 32767 X kwh,999 X 4

SYSTEM INFORMATION 427 System Operating Mode This output indicates the system operating mode for the air handling unit. 438 Actual Inlet Temperature setpoint The actual inlet temperature setpoint may vary from requested value, thus the actual setpoint is available here. C X 255 X = Stopped = Starting 2 = Auto / Running 3 = Stopping 4 = Filter Test Running 5 = Filter Calibration 6 = Night Cooling 7 = Holiday Mode 8 = Manual Mode 439 Actual Flow Setpoint The actual air flow setpoint may vary from requested value, thus the actual setpoint is available here, e.g. due % X 433 Pre Heater percent Preheaing suface is optional. % X Percentage heat output relative to maximum. 43 Comfort Heater percent Comfort heaing surface is optional. % X Percentage heat output relative to maximum. 432 Comfort Cooling percent Comfort cooling module is optional. % X Percentage cooling output relative to maximum. 435 Bypass Damper percent Bypass damper is optional. Percentage bypass position relative to maximum. means full heat recovery. % X = full heat recovery 428 System Condition This output indicates the system condition for the air handling unit. -32768 32767 X N.B.: Convert to binary representation 429 System Alarm This output indicates system alarms for the air handling unit. -32768 32767 X Bit = [Low Temp Process Inactive Active] Bit = [High Temp Process Inactive Active] Bit 2 = [Condensation Process Inactive Active] Bit 3 = [Non Critical Hardware Fault False True] Bit 4 = [Condenser Overheated False True] Bit 5 = [Compressor Locked False True] Bit 6 = [Filter Change Needed False True] Bit 7 = [High Room Temp False True] Bit 8 = [Abnormal Filter Test Calibration Result False True] Bit 9 = [Manual Override Active False True] Bit = [Comfort Cool Defrost Warning False True] Bit = [Comfort Cool Condensation Warning False True] Bit 2 = [Boost Mode Active False True] Bit 3 = [Comfort Cool Hotgas Warning False True] Bit 4 = [Comfort Cool Pressure Warning False True] Bit 5 = [Group Master Not Available Warning False True] N.B.: Convert to binary representation Bit = [Low Temp Alarm False True] Bit = [Condensation Alarm False True] Bit 2 = [Filter Alarm False True] Bit 3 = [Critical Hardware Fault False True] 5

SYSTEM INFORMATION 482 Hardware Errors LSB This output indicates the hardware status of the the air handling unit and cooling module. -32768 32767 X N.B.: Convert to binary representation Bit = [Room Temperaturesensor OK Fault] Bit = [Inlet Temperaturesensor OK Fault] Bit 2 = [Outside Temperaturesensor OK Fault] Bit 3 = [General Purpose Temperaturesensor OK Fault] Bit 4 = [Condenser Temperaturesensor OK Fault] Bit 5 = [Evaporator Temperaturesensor OK Fault] Bit 6 = [Exhaust Temperaturesensor Ventilation Unit OK Fault] Bit 7 = [Outside Temperaturesensor Ventilation Unit OK Fault] Bit 8 = [Supplyflow Sensor OK Fault] Bit 9 = [Supplyflow Sensor 2 OK Fault] Bit = [Extractionflow Sensor OK Fault] Bit = [CO2 Sensor OK Fault] Bit 2 = [Supply Fan OK Fault] Bit 3 = [Extraction Fan OK Fault] Bit 4 = [Evaporator In Temperaturesensor OK Fault] Bit 5 = [Evaporator Out Temperaturesensor OK Fault] 483 Hardware Errors MSB This output indicates the hardware status of the the air handling unit and cooling module. -32768 32767 X N.B.: Convert to binary representation Bit = [Hotgas Temperaturesensor OK Fault] Bit = [Comfort Cooling Connection Lost OK Fault] Bit 2 = [Comfort Cooling Stepdriver OK Fault] Bit 3 = [Comfort Cooling Frequency Inverter OK Fault] Bit 4 = [Humidity Supply Air Sensor OK Fault] Bit 5 = [Humidity Extraction Air Sensor OK Fault] Bit 6 = [Humidity Sensor Settings OK Fault] 43 Software Version Software version installed in the air handling unit. 32 6 X LOCAL CONTROL PANEL 469 Panel Flow Request Local control panel is optional. % X = no request from user Flow percent requested by the user via a local control panel. N.B.: Panel Flow Funktion (register 47). 47 Panel Flow Function This value defines how the air handling unit respond to a change of the airflow setpoint by the user via a local 2 X = Direct control panel. "Direct": The airflow setpoint can temporarily be overridden from a local control panel. "None": The airflow setpoint can not be overridden from a local control panel. "D-BMS": A change of the airflow setpoint from a local control panel will be shown at register 469, but will not affect the actual flow setpoint directly. N.B.: Manual Override Time (register 474). = None 2 = D-BMS 474 Manual Override Time This value defines for how long time an override of the airflow setpoint from a local control panel will be stored in the controller. hour(s) 8 2 X 6

SERVICE AND FILTER INFORMATION 465 Service hour count Operating hours since last service. N.B.: Multiply the value by to get actual hour count. 434 Filter, remaining service life [days] Estimated remaining service life of the filters in days calculated by the average daily operating hours since last 468 Remaining Service Life [Hours] service. Remaining service life of filters in operating hours. hour(s) 3 DIV days X hour(s) 65535 X 467 Remaining Service Life [%] Estimated remaining service life of filters in %. % X = filter change required = clean filters 466 Reset Filter Status The filter monitoring must be reset after a filter change. Set the value to to reset filter status. X = No The value will automatically return to when filter status has been reset. = Yes 475 Filter Test Mode This parameter defines the filter test mode. 3 3 X = Off "Timer": Filter monitoring using an hour counter. = Timer (default for air handling units with AQC-L) "Tacho": Electronic flow monitoring. 2 = Tacho "Timer and tacho": Filter monitoring using an hour counter and electronic flow monitoring. 3 = Timer And Tacho (default for air handling units with AQC-P) 476 Life Span Warning This value defines the operating hours before activating a filter warning at register 428. hour(s) 876 5 X The default value is 4 h for CV and DV product series. 477 Life Span Alarm This value defines the operating hours before activating a filter alarm at register 429. hour(s) 876 2 X The default value is 5 h for CV and DV product series. 478 Filter Max Life Time This value defines the maximum filter life time and for how many months the air handling unit can operate after a service reset before activating a filter alarm (register 429). The max life time alarm can be disabled by setting the value to. 479 Filter Warning Period This value defines the period for a filter warning at register 428 before the filter alarm activate s. By using the default value of this parameter the filter warning at register 428 is activated 2 months before the maximum filter life time expires (register 478). 47 Run Filter Calibration Set the value to to run a filter calibration. The value will automatically return to when the calibration process has finished. N.B.: Do only run a filter calibration with clean filters. N.B.: Do only run a filter calibration at the first start of an air handling unit with AQC-P control box by non standard installation e.g. on reduction of the duct size, when using more than m of duct or when installing with elbows. N.B.: A new filter calibration shall be performed if the filter class is changed (from M5 to F7 etc.) during a service routine of the air handling unit with AQC-P control box. month(s) 48 4 X month(s) 2 2 X X = No = Yes 7

Industrivej 59 DK - 96 Aars Denmark Tel: +45 98 62 48 22 Fax: +45 98 62 57 77 info@airmaster.dk www.airmaster-as.com Version: MODBUS RTU RS485-25--27