Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Similar documents
Inductive Proximity Sensor

Inductive Proximity Sensor

Inductive Proximity Sensor

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Inductive Proximity Sensor

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Inductive Proximity Sensor

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Cylindrical Proximity Sensor

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Transistor Remote Modules

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Inductive Proximity Sensor

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

E2EZ-X2D1-N E2EZ-X2D2-N

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Multiple Plunger Limit Switch

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

SYSMAC Transistor Remote Module

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

General Purpose Relay

1/16 DIN Temperature Controller E5CS

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Type Terminal Coil Contact form Model

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

A22NK. Key-type Selector Switches

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Inductive Proximity Sensor

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

General Purpose Relay

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Robust General-Purpose Limit Switch WL

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Model Pressure range ON/OFF output Linear output

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

General Purpose Relay

H3DS-X - Solid State Two-Wire Timer

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Safety-door Switch. Ordering Information

Hinged Safety Door Switch

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Sensing & Safety GENERAL CATALOGUE 2004/2005

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Digital display Pressure range ON/OFF output Linear output Model

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Surface mounting, flush mounting, and DIN track mounting

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Cylindrical Inductive Proximity Sensor GX-M SERIES

Analog Output Terminal

Model Number Structure

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Switching Power Supply

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Model Number Structure

E2K-L. Liquid Level Sensor. Applications. Ordering Information

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Model Pressure range ON/OFF output Linear output

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

DC2-Wire Unshielded Cylindrical Proximity Switches

Analog Input Terminal

Small Limit Switch D4V

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

AC/DC2-wire Type Cylindrical Proximity Switches

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Differential Pressure Sensor

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Manual Reset Limit Switch

SA1W: Water Detection Sensors

Transcription:

R Inductive Proximity Sensor Limit Switch Style Proximity Sensor with 5-Position Sensing Head H Sensing face easily adjusts to one of five directions H Easy to install and same mounting dimensions as a standard limit switch H Integrated short circuit and reverse polarity protection H Plastic body with stainless steel screws H Weld field immune models available H Conduit openings 1/2 -NPT and Brad Harrison MiniChange connector versions available Ordering Information J DC INPUT TYPE Type Sensing distance Output type Part number 1/2 -NPT conduit opening 4 -pin MiniChange connector* Shielded 20 mm (0.79 in) NPN (NO+NC) -N20E3 -U -N20E3-50 PNP (NO+NC) -N20F3 -U -N20F3-50 Unshielded 30 mm (1.18 in) NPN (NO+NC) -N30ME3 -U -N30ME3-50 Note: *Use Brad Harrison connector #104000A01F120 (12 foot) or equivalent. J AC INPUT TYPE Type Sensing distance Output type Part number PNP (NO+NC) - N30MF3 - U -N30MF3-50 1/2 -NPT conduit opening 4 -pin MiniChange connector* Shielded 15 mm (0.59 in) SCR (NO or NC) -N15Y4 -U -N15Y4-50 Unshielded 30 mm (1.18 in) SCR (NO or NC) -N30MY4 -U -N30MY4-50 Note: *Use Brad Harrison connector #103000A01F120 (12 foot) or equivalent. J WELD FIELD IMMUNE TYPES These sensors withstand 25,400 amps at 1 inch (100 mt). Type Sensing distance Input Output type Part number type 1/2 -NPT conduit opening MiniChange connector Shielded 15 mm (0.59 in) DC PNP (NO) -N15F1-51 -N15F1-52* AC SCR (NO or NC) -N15Y4-51 -N15Y4-52** Note: *Use 4-pin Brad Harrison connector #104000A01F120 (12 foot) or equivalent. **Use 3-pin Brad Harrison connector #103000A01F120 (12 foot) or equivalent. 2

Specifications J DC INPUT TYPES Part number -N15j -N20j -N30j Operating voltage 10 to 60 VDC; 10 to 30 VDC for weld -field immune types Current consumption 20 ma max. 10 ma max. Sensing object Ferrous metals Sensing distance 15 mm ±10%, shielded 20 mm ±10%, shielded 30 mm ±10%, unshielded Setting distance with standard sensing object (L x W x H mm) Differential travel Control outputp 0to12mm;0to15mm (45 x 45 x 1 mm, mild steel) 15% max. of sensing distance 0to16mm,0to20mm (60 x 60 x 1 mm, mild steel) Type F1: PNP-NO E3: NPN (NO+NC) F3: PNP (NO+NC) Max. load 200 ma Max. on -state 3 VDC at 200 ma load current voltage drop Response frequency 10 Hz (weld field immune) 150 Hz 100 Hz Circuit protection Reverse polarity, output short-circuit Weld field immunity 25,400 amps at 1 inch (100 mt) Indicator Operating indicator (yellow LED) Material Case PBT Terminal base Aluminum Sensing face PBT Connections -U, -51: 1/2 -NPT conduit opening; -G: PG 13.5 conduit opening -50, -52: 4-pin MiniChange connector Enclosure rating IP67 (EN 60947-1) Approvals UL listed, CSA certified Operating ambient temperature - 25_ to 70_C (-13_ to 158_F) Relative humidity Influence of temperature Dielectric strength 35% to 95% RH Electromagnetic compatibility EN 60947-5-2 ±10% max. of sensing distance at 23_C (73.4_F) in temperature range of - 25_ to 70_C (-13_ to 158_F) 1,500 VAC, 50/60 Hz for 1 minute between current carrying parts and case Vibration resistance 10 to 55 Hz, 1 mm amplitude according to IEC 60068-2 -6 Shock resistance Approx. 30 G for 11 ms according to IEC 60068-2 -27 0to24mm,0to30mm (90 x 90 x 1 mm, mild steel) ME3: NPN (NO+NC) MF3: PNP (NO+NC) 3

J AC INPUT TYPES Part number -N15Yj -N30MY4j Operating voltage 20 to 253 VAC, 50/60 Hz Current consumption 20 ma max. 10 ma max. Leakage current Sensing object 1.9 ma max. (2.5 ma max. for weld field immune types) Ferrous metals Sensing distance 15 mm ±10%, shielded 30 mm ±10%, unshielded Setting distance with standard sensing object (L x W x H mm) Differential travel 0to12mm;0to15mm (45 x 45 x 1 mm, mild steel) 15% max. of sensing distance Control Type SCR (NO or NC) output Max. load 500 ma Min. load 8 ma (10 ma for weld field immune types) Max. on -state voltage drop 12 VDC at 500 ma load current Response frequency 20 Hz Circuit protection None Weld field immunity 25,400 amps at 1 inch (100 mt) Indicator Operating indicator (yellow LED) Material Case PBT Terminal base Aluminum Sensing face PBT Connections -U, -51: 1/2 -NPT conduit opening; -50, -52: 3-pin MiniChange connector Enclosure rating IP67 (EN 60947-1) Approvals UL listed, CSA certified Operating ambient temperature - 25_ to 70_C (-13_ to 158_F) Relative humidity Influence of temperature Dielectric strength 35% to 95% RH Electromagnetic compatibility EN 60947-5-2 0to24mm,0to30mm (90 x 90 x 1 mm, mild steel) ±10% max. of sensing distance at 23_C (73.4_F) in temperature range of - 25_ to 70_C (-13_ to 158_F) 1,500 VAC, 50/60 Hz for 1 minute between current carrying parts and case Vibration resistance 10 to 55 Hz, 1 mm amplitude according to IEC 60068-2 -6 Shock resistance Approx. 30 G for 11 ms according to IEC 60068-2 -27 4

J OUTPUT CIRCUIT DIAGRAMS AND TIMING CHARTS NPN (NO + NC) Output 1 Brown +V -NjjjE3 -j Output NO NC Target 4.7 kw 4.7 kw (output) indicator Main circuit 4 Black NO output 2 White NC output 3 Blue - V PNP- NO Output (Weld Field Immune Models) Main circuit 1 Brown 4 Black Output +V -N15F1-5j Output Target NO 4.7 kw (output) indicator 3 Blue - V 5

PNP (NO + NC) Output Main circuit 1 Brown 2 White NC output 4 Black NO output +V -NjjjF3 -j Output NO NC Target 4.7 kw 4.7 kw (output) indicator 3 Blue - V AC (NO or NC) Output -NjjjY4 -j Main circuit 3 4 L1 NO output N Output NO NC Target (output) 1 2 L1 NC output N indicator LY E OUTPUT ALLOWED! 6

Dimensions Unit: mm (inch) J -Njjjj - U AND - 51 TYPE 40 (1.57) 11 (0.43) 118 (4.65) 58 (2.28) 40.5 (1.59) LED(s) 40 (1.57) 1/2 - NPT 30 (1.18) 46.5 (1.83) 60 (2.36) 5.5 (0.22) J -Njjjj - 50 A N D - 52 TY P E 40 (1.57) 11 (0.43) 133 (5.24) 118 (4.65) 58 (2.28) 40.5 (1.59) LED(s) MiniChange connector 40 (1.57) 30 (1.18) 46.5 (1.83) 60 (2.36) 5.5 (0.22) 7

Installation J PIN ARRANGEMENT MiniChange connections 8

Precautions! CAUTI Power supply Do not impose an excessive voltage on the, otherwise it may explode or burn. Do not impose AC voltage on any DC model, otherwise it may explode or burn. Sensor Brown Blue Black Incorrect Do not connect the AC types without load to the power supply. The sensor will be damaged. Sensor J INSTALLATI Power Reset Time The Proximity Sensor is ready to operate within 300 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto -transformer. Sensing Object Metal coating: The sensing distance of the proximity sensor will vary with the metal coating on sensing objects. J WIRING High- Tension Lines Wiring through Metal Conduit If there is a power or high -tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. J MOUNTING The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water resistance. J ENVIRMENT Water Resistance Do not use the proximity sensor underwater, outdoors or in the rain. Operating Environment Be sure to use the Proximity Sensor with operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistant, a cover to protect he proximity sensor from water or soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gases including nitric, chromic, and concentrated sulfuric acid gases). NOTE: DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMR ELECTRICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMR OMR -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci OMR CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.