Inductive Proximity Sensor

Similar documents
Inductive Proximity Sensor

Inductive Proximity Sensor

Inductive Proximity Sensor

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Inductive Proximity Sensor

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Cylindrical Proximity Sensor

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Inductive Proximity Sensor

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Model Pressure range ON/OFF output Linear output

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

E2EZ-X2D1-N E2EZ-X2D2-N

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Cylindrical Inductive Proximity Sensor GX-M SERIES

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

Cylindrical type proximity sensor

AC/DC2-wire Type Cylindrical Proximity Switches

Inductive Proximity Sensor

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

DC2-Wire Unshielded Cylindrical Proximity Switches

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Sensing & Safety GENERAL CATALOGUE 2004/2005

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Transistor Remote Modules

Digital display Pressure range ON/OFF output Linear output Model

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

Cylindrical Proximity Sensor E2GN

Model Pressure range ON/OFF output Linear output

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Switching Power Supply

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

A22NK. Key-type Selector Switches

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

Inductive Proximity Sensor

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

Small Limit Switch D4V

Model Number Structure

Chandrashekar.p. Electrical and Electronics Engineering, PESITM-Shivamogga, Karnataka-India

SA1W: Water Detection Sensors

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

ABL Series. Relay Terminal Block (Screwless Type) Features

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Analog Output Terminal

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Differential Pressure Sensor

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

Safety Interlock Switches

Surface mounting, flush mounting, and DIN track mounting

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Installation and Operating Instructions for ROBA -takt Switch Gear Type

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Rectangular-shaped Inductive Proximity Sensor.

Analog Input Terminal

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

Sensor specifications Model no.

User Manual of 2MA2282

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Model Number Structure

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Installation Instructions - K-Safe-T-Rip Belt Rip Detector

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

HL (AZH) LIMIT SWITCHES

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

HL (AZH) Limit Switches

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

SG-B1 SERIES / SG-A1 SERIES

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Operating Manual For Stepper Driver

Transcription:

Inductive Proximity Sensor ASH & ALAIN INDIA PVT LTD S100, F.I.E.E., Okhla Industrial Area, Phaseii, New Delhi110020(India) Tel : 01143797575 Fax : 01143797574 Email : sales@ashalain.com E2Q4 Square Proximity Sensor M12 Plugin connection Integrated short circuit and reverse polarity protection Active face positioning: Yaxis 15, Xaxis 90 increments Ordering Information Sensing Connection Active face Output distance NO NO NC Prewired Changeable NPN E2Q4N20E1 E2Q4N20E3 20 mm Prewired PNP E2Q4N20F1 E2Q4N20F3 shielded Plugin Changeable NPN E2Q4N20E1M1 E2Q4N20E3M1 connector PNP E2Q4N20F1M1 E2Q4N20F3M1 Prewired Changeable NPN E2Q4N30ME1 E2Q4N30ME3 30 mm Prewired PNP E2Q4N30MF1 E2Q4N30MF3 non Plugin Changeable NPN E2Q4N30ME1M1 E2Q4N30ME3M1 shielded connector PNP E2Q4N30MF1M1 E2Q4N30MF3M1 Accessories: For connector please contact us.

Specification Operating voltage 10 to 30 VDC Current consumption max. 20 ma Sensing object Ferrous metals Sensing distance Sn (Standard target size, L x W x H, Fe 37) E2Q4N20.. E2Q4N30M.. E2Q4N20.. E2Q4N30M.. 20 mm ±10%, shielded 30 mm ±10%, non shielded (60 x 60 x 1 mm) (90 x 90 x 1 mm) Setting distance E2Q4N20.. E2Q4N30M.. 0 to 16,2 mm 0 to 24,3 mm Differential travel 15 % max. of sensing distance Sn Switching frequency 150 Hz Control output Type E2Q4N20E1: NPN NO E2Q4N20E1 M1: NPN NO E2Q4N20F1: PNP NO E2Q4N20F1M1: PNP NO E2Q4N20E3: NPN NO NC E2Q4N20E3M1: NPN NO NC E2Q4N20F3: PNP NO NC E2Q4N20F3M1: PNP NO NC E2Q4N30ME1: NPN NO E2Q4N30ME1M1: NPN NO E2Q4N30ME3: NPN NO NC E2Q4N30ME3M1: NPN NO NC E2Q4N30MF1: PNP NO E2Q4N30MF1M1: PNP NO E2Q4N30MF3: PNP NO NC E2Q4N30MF3M1: PNP NO NC Max Max onstate voltage drop 200 ma 3 VDC (at 200 ma load current ) Circuit protection Reverse polarity, output short circuit Indicator Operating indicator (yellow LED) Ambient temperature Operating: 25 to 70 C Humidity 35 to 95 % RH Influence of temperature ± 10 % max. of Sn at 23 C in temperature range of 25 to 70 C Dielectric strength 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC EN 6094752 Vibration resistance 10 to 55 Hz, 1 mm amplitude according to IEC 6006826 Shock resistance approx. 30 G for 11 ms according to IEC 60068 227 Degree of protection IP 67 (EN 609471) Connection Prewire 2 m PVCCable, 3x0,34mm² / 4x0,34mm² Plugin connection M12 plug, 3 / 4 pins Material Case PBT Sensing face PBT Approvals 2 CERTIFIED LISTED

Output Circuit Diagram and Timing Chart NPN NO NC output 1 / V Main circuit 4 / NO output 2 / White NC output 3 / V PNP NO NC output 1 / V Main circuit NC output 2 / White NO output 4 / 3 / V 3

M12 connections NPN NO PNP NO Male receptable end view 2 1 1 2 NPN NO NC PNP NO NC Male receptable end view 1 2 White N.C. N.O. N.C. N.O. 1 2 White Dimensions E2Q4N... E2Q4N...M1 Caution Item Examples Power Supply Do not impose an excessive voltage on the E2Q4, otherwise it may explode or burn. Do not impose AC voltage on any E2Q4 DC model, otherwise it may explode or burn. 4

Correct Use Installation Power Reset Time The Proximity Sensor is ready to operate within 300 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an autotransformer. Sensing Object Metal Coating: The sensing distance of the Proximity Sensor vary with the metal coating on sensing objects. Wiring Hightension Lines Wiring through Metal Conduit If there is a power or hightension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose the waterresistivity. Environment Waterresistivity Do not use the Proximity Sensor underwater, outdoors or in the rain. 5

E2Q4 E2Q4 Operating Environment Be sure to use the Proximity Sensor within operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e. g., strong alkaline or acid gases including nitric, chromic, and concentrated sulfuric acid gases). DC Type Connection type AND (serial connection) OR (parallel connection) Method Description The Sensors connected together must satisfy the following conditions: i L (N1) x i Upperlimit of control output of each Sensor V S N x V R operating voltage N = No. of Sensors V R = Residual voltage of each Sensor V S = Supply voltage i = Current consumption of the Sensor i L = current If the MY Relay, which operate at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. A minimum of three Sensors with current outputs can be connected in parallel. The number of Sensors connected in parallel varies with the Proximity Sensor model. ASH & ALAIN INDIA PVT LTD S100, F.I.E.E., Okhla Industrial Area, Phaseii, New Delhi110020(India) Tel : 01143797575 Fax : 01143797574 Email : sales@ashalain.com 6