Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Similar documents
Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

OPERATION MANUAL SUBMERSIBLE FOUNTAIN PUMP PM2 600LV PM2 900LV PM2 1500LV PM2 2400LV PM2 4500LV

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual

Sump Pump. Installation and Operating Instructions

Domestic Water Supply Pressure Pumps

Bianco Rainsaver MK3 Installation and Operating Instructions. The no brainer. Bianco Rainsaver MK3 & MK3E Installation and Operating Instructions

Gun 300 Handpiece INSTRUCTION MANUAL. Ph: (02) Refer to instruction book before use.

OWNER S OPERATING MANUAL

VERSION 2017 V.1.0

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

OWNER S OPERATING MANUAL

AL-KO ESC USER MANUAL

StormPro BA Series Sump Pump

OWNER S OPERATING MANUAL

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

PRODUCT RANGE NEW PUMP PERFORMANCE

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Motion Sensing Coach Light

WETech Active Trimmer

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

Installation and Operating Instructions

ELECTRIC LIFTING HOIST

Installation and Operating Instructions for

OWNER S MANUAL Please read this manual before operating your power supply

StormPro BCV400 Sewage Ejector Pump

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

INSTRS30709 rev 1 02/10/09 Page 1

GBC Polar A4 & A3 Laminators. Instruction Manual

Owner s Manual Drill and Light Weight Portable Utility Pumps

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

INSTALLATION AND OPERATING INSTRUCTIONS

AL-KO OFF-ROAD BALL COUPLING USERS MANUAL

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OWNER S OPERATING MANUAL

PRODUCT MANUAL. Backpack Sprayer 12L

Owner s Manual. H03548 Rev A

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

TPAK Series COOLANT PUMP

Matson Programmable Voltage Sensitive Relay MA98411

PRODUCT MANUAL. Heavy Duty Backpack Sprayer 16L

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1

AL-KO OFF-ROAD PIN COUPLING USERS MANUAL

BATTERY METER SMART BATTERY GUAGE

EXTRA WIDE STEEL ROLLATOR

RECOMMENDATIONS Turbosmart recommends that your Blow off valve (BOV) is fitted by an appropriately qualified technician

SUBMERSIBLE WATER PUMPS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

SIGMA PNEUMATIC CARE BUTTON

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER.

K681. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 2 x 2 x 2. x 2. Revision No: 4D 1

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

GWA BATHROOMS & KITCHENS WARRANTY PERIODS

Handling Belts. ARTG No: LM53072 LM53073

650mA Phase Dimmable LED Driver

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

ROCA DUO PLUS OVAL INSET BATH

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1

Rainsaver MK4E RAINWATER HARVESTING SYSTEMS

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

Part Number: DBDC10 / DBDC20 DC to DC Dual Battery Charger Manual

RECOMMENDATIONS Turbosmart recommends that your Blow off valve (BOV) is fitted by an appropriately qualified technician

PRODUCT MANUAL. Heavy Duty Shoulder Sprayer 5L & 8L

SUNC3000 / Item #40885

CONTENTS. Calibration Self Check & Technical Specifications 13 Care & Maintenance, Trouble Shooting 15 Warranty 16

K682. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 8. x 4 x 2 x 2 x 4. x 4 x 4 x 4. Revision No: 1A 1

B 3000 Instant Chilled Filtered Water System. User guide

12V SUBMERSIBLE BILGE PUMP

230VAC Power Inverter 400W Owner s Manual

K163. Fitting Kit. Fitting Instructions for Basic Carrier. x 4. Revision No: 2C 1

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

INSTALLATION AND OPERATING INSTRUCTIONS

1000mA - 650mA Phase Dimmable LED Driver

POLYCRYSTALLINE SOLAR PANELS. (MC4 Series) P/No SPP80-MC4, SPP120-MC4, SPP135-MC4, SPP150-MC4

Part Number: DCDC10S / DCDC20S DC to DC Dual Battery Charger Manual

SUBMERSIBLE WATER PUMP

SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

OWNER S MANUAL. Horizontal Multistage Centrifugal Pumps. SMH Range

ESE Series Cast Iron Sewage Pumps

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

K440. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. x 1 x 1 x 4 x 1. Revision No: 10J 1

C3 Operating Instructions

OWNER S OPERATING MANUAL

CEMENT MIXERS & MACHINERY USER & WARRANTY GUIDE. Electric and Petrol Models

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

Euro Lightweight Wheeled Walker

Issue 3. Description: ROBINHOOD TAP PULL-OUT SERIES Model Numbers: TPO1200. Model may vary slightly from image pictured

Rainsaver MK3E RAINWATER HARVESTING SYSTEMS

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

K309. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 2 x 2 x 4. x 1 x 2 x 1. Revision No: 7C 1

K500. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 4. Revision No: 14N 1

Q20. Track System. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 1. x 1 x 1 x 4 x 4. Revision No: 1A 1

Transcription:

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Installation & Operating Instructions BIANCO B range of submersible pumps is suitable for small to medium dewatering and or wastewater applications. The Vortex pumps (VA) are able to pump soft solids in suspension. The KA cutter pump has a impeller with an edged tungsten tip and a grinding plate to assist with cutting of fibrous materials. The G grinder pump consists of a high chrome impeller and grinder which can grind soft solid materials in sewage. Dewatering Pumps: B10A, B15A, B25A, B40A, B42A, B75A Vortex Pumps: B15VA, B25VA, B40VA, B75VA Cutter Pump: B75KA Grinder: B120G Voltage: 240V 50Hz Single Phase Submersible pumps are very quiet and are ideal for applications within residential areas for storm water pits, basements, etc Suitable Fluids The Cutter (K) models are suitable for pumping soft solids in suspension. The Cutter and Grinder (G) pumps are also suited to pump soft string-like materials such as hair, lint, straw etc. Grinder models can pump cloth, rubber gloves, etc. The cutter and grinder pumps should not pump hard solids as these will damage the pump face. Pumps are not to be used for pumping flammable or corrosive fluids. Installation The BIANCO B series pumps are completely submersible up to 10 metres and can be installed on a level surface in a stationary position connected to either fixed pipe work or flexible hose. Never remove or lift a pump by the power cable. Instead connect a rope to the handle during installation. External float switch versions should be placed in a sump of a suitable size so that the float switch is not restricted or could be caught in the up position. The float switch must be installed so that the ON and OFF operating points can be easily reached, and that the float switch head is not too close to the latching holder which prevents correct operation. The float switch must not touch the base of the sump or tank which will prevent the pump turning off. All pumps must not be allowed to run dry. Motor Cooling All models rely upon water flow around the motor for correct motor cooling. All models are suitable to operate partially submerged for periods up to 10 minutes. Operating at very low flows caused by high heads or restricted pipe work may cause motor over heating.

Power Connection A power point (10 amp) should be provided by a qualified electrician, and a residual current device with a nominal trip current should be installed in compliance with the requirements of AS 3000. All single phase models have an automatic reset thermal overload protection built in, and overload will switch the motor off and later will automatically reset and switch the motor on when the motor has cooled down. The appliance (pump) is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, the pump should be returned to White International or one of its Service Agents for repair in order to avoid a hazard. Trouble Shooting Fault Cause Remedy Pump does not start No mains supply Check that power is available and switch is on Blown fuse or tripped breaker Replace or reset Impeller jammed Disconnect power and clean impeller area Pump has turned off on thermal cut out Allow time to reset Float switch jammed down Free switch and move pump Insufficient water level Float switch must be 45 deg above horizontal No or low flow Strainer or impeller blocked by debris Clean strainer and impeller Airlock in discharge pipework Ensure pump body is filled with water Discharge hose is bent or kinked Straighten discharge hose Damage caused by dirty or abrasive water Clean pump and replace parts Excessive friction loss or delivery head Increase pipe size and increase pump size. Pump will not turn off Float switch jammed up Free switch and move pump Excessive friction loss or delivery head Increase pipe size and increase pump size. Pump switches off after short period Thermal overload has tripped Ensure impeller is not clogged Ensure water temperature is below 35 deg C Ensure pump not operating on extension lead Ensure pump not operating at low flow

C C B A B A Dimensions (mm) Model A B C BIA-B10A 132 186 304 BIA-B15A 132 186 304 BIA-B25A 131 196 314 BIA-B40A 143 224 350 BIA-B75A 173 289 488 BIA-B15VA 132 186 304 BIA-B25VA 131 196 314 BIA-B40VA 143 224 350 BIA-B75VA 155 260 435 BIA-B75KA 195 280 420 BIA-B120G 198 237 540

BIA-B42A Dimensions

2 YEAR WARRANTY Terms & Conditions White International Pty Ltd Limited Product Warranties TERMS & CONDITIONS This warranty is given in addition to the consumer guarantees found within the Australian Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand: 1) White International Pty Ltd / White International NZ Ltd (White International) warrant that all products distributed are free from defects in workmanship and materials, for their provided warranty period as indicated on the top or opposite side of this document. Subject to the conditions of the warranty, White International will repair any defective products free of charge at the premises of our authorised service agents throughout Australia and New Zealand if a defect in the product appears during the warranty period. If you believe that you have purchased a defective product and wish to make a claim under this warranty, contact us on our Sales Hotline on 1300 783 601, or send your claim to our postal address or fax line below and we will advise you as to how next to proceed. You will be required to supply a copy of your proof of purchase to make a claim under this warranty. 2) This warranty excludes transportation costs to and from White International or its appointed service agents and excludes defects due to non-compliance with installation instructions, neglect or misuse, inadequate protection against the elements, low voltage or use or operation for purposes other than those for which they were designed. For further information regarding the suitability of your intended application contact us on our Sales Hotline on 1300 783 601. If you make an invalid claim under this warranty, the original product will be sent back to you unrepaired. 3) This warranty refers only to products sold after the 1st January 2012, and is not transferable to another product type and only applies to the original owner, purchaser or end user, and is in addition to the consumer guarantees found within the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 4) Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

5) To the fullest extent permitted by law, White International excludes its liability for all other conditions or warranties which would or might otherwise be implied at law. To the fullest extent permitted by law, White International s liability under this warranty and any other conditions, guarantees or warranties at law that cannot be excluded, including those in the Competition and Consumer Act 2010 (Cth), is expressly limited to: (a) in the case of products, the replacement of the product or the supply of equivalent product, the payment of the cost of replacing the product or of acquiring an equivalent product or the repair of the product or payment of the cost of having the product repaired, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand; and 6) To the fullest extent permitted by law, this warranty supersedes all other warranties attached to the product or its packaging. 7) In the case of services, supplying the services again or the payment of the cost of having the services supplied again, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 8) Our warranty commences from the date of purchase of the above mentioned pumps. Proof of purchase is required before consideration under warranty is given. Record your date of purchase in the space below and retain this copy for your records. Date of Purchase... Model Purchased... WHITE INTERNATIONAL PTY LTD ABN 48 000119380 WHITE INTERNATIONAL NZ LTD 52-60 Ashford Ave, MILPERRA NSW 2214 138 Hugo Johnston Dr PENROSE, AUCKLAND, NZ PO BOX 304, MILPERRA LPO NSW 2214 PO BOX 12704, PENROSE, AUCKLAND Ph: 02 9783 6000 Fax: 02 9783 6001 Ph: 09 579 977 Fax: 09 579 7775 Customer Service Hotline: 1300 783 601 Customer Service Hotline: 0800 509 506 Customer Service Faxline: 02 9783 6003 Customer Service Faxline: 0800 804 344 EMAIL: Sales Enquiries: info@whiteint.com.au EMAIL: General Info Enquiries: sales@whiteint.co.nz