SUBMERSIBLE WATER PUMPS

Similar documents
SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

SUBMERSIBLE WATER PUMP

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE DIRTY WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

POND PUMP Model Nos:SPP3 & SPP6 0200

28W WORK LAMP Model: CTL28 Part No:

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

OPERATING & MAINTENANCE INSTRUCTIONS

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

1 ELECTRIC WATER PUMP

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

BATTERY/BOOSTER CHARGER. Model No: BC100N Part No: OPERATING & MAINTENANCE INSTRUCTIONS

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

BENCH GRINDER MODEL CBG6RP OPERATING & MAINTENANCE INSTRUCTIONS 0101

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

LEAD ACID BATTERY CHARGER

KING 130 HOT WASHER Part No Product Serial No:...

CFT24 &CFT230 PART NOS:

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

BOOSTER PUMPS Models Nos: BPT600 & BPT1200SS Part Nos: &

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

OPERATING & MAINTENANCE INSTRUCTIONS

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

HOT AIR GUN MODEL No. CHG 1500B Part No

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

1200W INVERTER GENERATOR

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

1100W PORTABLE GENERATOR

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Installation & Operating Manual

KING 135 HOT WASHER Part No OPERATING & MAINTENANCE INSTRUCTIONS 0702

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

MODEL No. BC 700. Par t No OPERATING & MAINTENANCE INSTRUCTIONS

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS145, 145R & ELS160R. Part Nos , &

ORIGINAL INSTRUCTIONS

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

OPERATION & MAINTENANCE INSTRUCTIONS

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

Matala. VersiFlow Series. Instruction and Maintenance Manual

OPERATION & MAINTENANCE INSTRUCTIONS

GARDEN HOSE UTILITY PUMP

Car Battery Charger Instructions for Use

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

RANGER 45 / 65 AIR COMPRESSOR

Sump Pump. Installation and Operating Instructions

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

RECHARGEABLE SPOTLIGHT

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

MODEL P INSTALLATION INSTRUCTIONS

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

OPERATION & MAINTENANCE INSTRUCTIONS

Owners Manual: - Pumps

SPOT WELDER. Models CSW11 & CSW11T OPERATING & MAINTENANCE INSTRUCTIONS. Part No &

Submersible Pump Instructions. Safety Instructions

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

GeyserMax-Flow Series

12 amp RMS Battery Charger

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

OWNERS MANUAL ECODIVER

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

SuperFlo 9,000 High Volume Pump Product Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

RECHARGEABLE SPOTLIGHT

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

INSTALLATION & OPERATION MANUAL

9 (230mm) ANGLE GRINDER Model No. CAG232

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

ENGINE DRIVEN 3 FULL TRASH PUMP

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

SUNC3000 / Item #40885

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

SUBMERSIBLE SUMP PUMPS

Transcription:

SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000

CONTENTS Warranty conditions... 3 Safety Precautions... 3 Electrical Connections... 4 Features... 5 Installation... 6 Maintenance... 7 Trouble Shooting... 8 Pump Specifications... 9-10 Spare Parts and Servicing... 11 SPARE PARTS & SERVICING A range of suitable hose is available from your CLARKE dealer For Spare Parts and Service,please contact your nearest dealer, or CLARKE International, on one of the following numbers. PARTS & SERVICE TEL: 020 8988 7400 PARTS & SERVICE FAX: 020 8558 3622 or e-mail as follows: PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com 2

Thank you for purchasing this Clarke Submersible Pump. These highly efficient pumps are designed for pumping clean water, or water containing sand or solids in suspension, (please see Features, page 5), and are ideally suited for draining ponds, pools, building excavations etc., where water temperature does not exceed 50 C. These pumps are NOT suitable for pumping salt water, or for permanent installation in fish ponds as the acidity, found in fish ponds, will damage the pump seals. Before attempting to operate your pump, please read this instruction manual thoroughly and follow all directions carefully. This is for your own safety and that of others around you, and to help you achieve long and trouble free service from your pump. GUARANTEE This product is guaranteed against faults in manufacture for 12 months from purchase date. Keep your receipt as proof of purchase. This guarantee is invalid if the product has been abused or tampered with in any way, or not used for the purpose for which it is intended. The reason for return must be clearly stated. This guarantee does not affect your statutory rights. Please note that dismantling this pump will invalidate the guarantee SAFETY PRECAUTIONS 1. These pumps are designed to pump WATER ONLY. Never use for pumping flammable liquids or chemicals of any kind. 2. Never run the pump dry. 3. An approved Residual Current Device (RCD) MUST be used when pumping from ponds or swimming pools. 4. Your submersible pump may ONLY be used for pumping water from a swimming pool when there is no person or animal in the pool. 5. Always disconnect the pump from the electrical supply before placing into, or removing from the water, and before any cleaning or maintenance of the pump. 6. Always use the handle, with a rope or chain attached when lifting the pump. NEVER lift thepump by the mains cable, or, where fitted, the float switch cable. 7. DO NOT run the pump with the body exposed for longer than 10 minutes. 8. DO NOT install the pump on sand, silt, mud etc., or ground which is likely to shift. 9. If pumping water which is below 0 o C, the pump MUST be run continuously, otherwise the pump must be removed from the water and stored in a frost free location. 10. If the pump is to be used where there may be silt or mud (e.g., garden ponds), keep the pump clear of any sedimentby standing it on a platform or brick or suspending from a rope attached to the handle 3

ELECTRICAL CONNECTIONS All models should have their mains lead connected to a standard 230Volt (50Hz) electrical supply through an approved plug or a suitably fused isolator switch. We recommend that these pumps be fitted with a Residual Current Device (RCD). NOTE: This is mandatory when pump is used for pumping swimming pools and ponds If the pump is to be connected to an outdoor electrical supply, make sure that both the plug and the socket are of a BS approved waterproof design. In the event that the pump is hard wired into the electrical system, it must be carried out in accordance with IEE regulations. If used for draining swimming pools or ponds, the pump MUST be fitted with a Residual Current Device (RCD), with a rated residual operating current of no greater than 30mA. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in the mains lead are coloured in accordance with the following code: Green & Yellow - Earth Blue - Neutral Brown - Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows: Connect GREEN & YELLOW cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW. Connect BROWN cord to terminal marked with a letter L or coloured RED Connect BLUE cord to terminal marked with a letter N or coloured BLACK FUSE RATING The fuse in the plug for this appliance must be rated at 13 amps. If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. nonrewirable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. Should you wish to replace a detachable fuse carrier, ensure that the correct replacement is used (as indicated by marking or colour code). 4. Replacement fuse covers can be obtained from your local dealer or most electrical outlets 5. The fuse in the plug must be replaced with one of the same rating (13 amps) and this replacement must be ASTA approved to BS1362. IMPORTANT: If you are in any doubt regarding electrical installation, you should consult a qualified electrician. 4

FEATURES These pumps are of rugged and durable construction, designed for long lasting continuous operation and their stainless steel bodies provide good anti corrosive properties. The motor is provided with built in overload protection. For your information the charts, on pages 9 and 10, show the flow rate for each pump at various heads. (HEAD is the distance, or height, from the surface of the water to the point of discharge) These pumps are designed to pump water containing solids in suspension. That is - with a maximum of 5% solid content, and a maximum 3mm solid dia. They are NOT designed for pumping slurry, sludge, mud or heavily polluted water, and should NOT be used for PERMANENT INSTALLATION in fish ponds or any water containing chemicals or other acidic contaminants including salt water. Whenever the pump is used to pump contaminated water, e.g. to drain fish ponds etc., you must ALWAYS immerse the pump in clean water and run it for a few minutes on completion, to ensure it is completely cleansed of all contaminants. The maximum depth to which these pumps should be submerged is 5 Metres. Automatic Pumps, i.e. those fitted with a Float Switch, denoted by an A suffix to their model number, are suitable for permanent or semi-permanent installations, e.g. installations where it is necessary to maintain a water at a particular level. As the water level rises, so will the float. At a certain point the switch will operate and start the pump. As the water level falls, so will the float until the switch operates again and stops the pump. Float switches are adjusted at the factory to provide the correct ON-OFF switching mode, i.e. cut out when the depth of water is 40mm and will cut in again when the level reaches 300mm. You can adjust the level at which the pump cuts out by sliding the float switch cable through the clip attached to the main body. Shorten or lengthen it as the case may be. The shorter it is, the earlier the pump will cut out, and the water therefore will be deeper at this point. Similarly, it will cut in earlier and the water will therefore be shallower when it does so. 5

It should not normally be necessary to change the length of cable (from the clamp to the float switch), but should you do so, remember that the cable length should NEVER be so long that the float switch fails to operate and switch the pump OFF. ALWAYS check its operation before use. INSTALLATION All pumps are complete with an Outlet Hose Adapter which simply screws into the outlet port on top of the pump body. Model CS85 is provided with a 1 BSP threaded adapter which will accept a 1 I.D. hose. Models CS120 and 185 are provided with a 1¼ BSP threaded, two stage adapter, which will accept either a 1 or 1 ¼ I.D. hose. Models CS240 and 305 are provided with a 1½ BSP threaded adapter which will accept a 1½ I.D. hose. Ensure the hose is secured with a suitable worm drive clip (not supplied). If the pump is to be used for drainage purposes, or in situations that demand maximum efficiency, we strongly recommend that you connect the largest diameter hose possible to the outlet hose adapter, as small diameter hoses reduce capacity and put additional strain on the motor. If a 1¼ hose is used with models CS120 & 185, it will be necessary to cut off the 1 diameter fitting at the joint between the two. Do not slide the 1¼ hose over the 1 fitting as the 1 fitting will act as a restriction. The pumps are completely submersible and must be placed in a vertical position on a solid flat surface. If this is not available, sit the pump on house bricks, or something similar, and ensure that this type of support is not likely to shift. The pump should be well clear of silt, mud or any type of marine growth. IMPORTANT: ALWAYS raise and lower the pump using a rope attached to the lifting eye, where fitted, or to the lifting handle, NEVER by the power cable. Automatic versions should be placed in a sump which has adequate dimensions so as not to restrict the movement of the float switch. Please note that the symbo on the pumps Rating Plate, denotes the MAXIMUM depth to which the pump may be submerged, in metres. Take all necessary precautions as described on page 2 before plugging in, and switching ON. SUITABLE HOSE, and SPARE/REPLACEMENT HOSE ADAPTERS ARE AVAILABLE FROM YOUR CLARKE DEALER 6

MAINTENANCE WARNING Before checking the condition of the pump, ensure it is unplugged from the mains supply. If the unit is hard wired, ensure the circuit breaker is open. Check the pump installation regularly to ensure the base inlet is clear of leaves or other debris. Note that these pumps are fitted with automatic thermal overload protection. If the pump overheats due to an obstruction in the pump, or pumping warm water in excess of 50 o C for example, it will shut off automatically. Switch the pump OFF and disconnect from the mains supply. Check for blockages and allow the motor to cool (at least 15 minutes) before attempting to restart. These pumps should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. Do not use the pump if there is any damage to the mains supply cable, or to the float switch or its cable. Do not attempt to repair the pump yourself, as you may damage the waterproof seal and invalidate your guarantee. Repairs must be carried out by your CLARKE dealer, or contact the CLARKE Service Department, on 0208 556 4443. If the pump becomes badly clogged, the stainless steel strainer may be removed and cleaned by removing the screws, on the underside of the strainer, which secure it to the main body. Back flush the pump by removing the inlet hose adapter and directing a jet of clean water through the inlet port. IMPORTANT Do not attempt to strip the pump further as this will invalidate the guarantee 7

TROUBLE SHOOTING A. PUMP WILL NOT START 1. Manual type (i.e. without float switch) 1.1 Check to ensure Power is switched on. 1.2 Check fuse (consult an electrician if in doubt). 1.3 If extension lead is fitted, check connections (consult an electrician if in doubt). 1.4 Internal thermal cutout has not reset. Leave for 5 minutes and try again. 1.5 The Impeller may be jammed. Disconnect from the mains supply, remove the bottom strainer and remove any objects that may be obstructing the impeller. Replace the strainer and try again. If the pump still fails to start, consult your CLARKE dealer for advice. 2. Automatic Type (with float switch) 2.1 Check all above. 2.2 Float switch may be jammed against side wall, or prevented from moving. 2.3 Water level too low - float switch in OFF position - Lift float to check switch. B. PUMP WILL START BUT NOT PUMP 1. Water level too low - below the minimum suction level (Manual type). 2. Check to ensure strainer is not blocked. 3. Discharge tube clogged or obstructed. 4. The head may be too great, i.e. you are trying to lift the water too great a distance for the pump to cope with. (See specifications pages 9-10 ). 5. Air bubble in the pump, produced during the plunge. Plunge the pump again, at an angle, and shake it whilst lowering to remove any air trapped in the system. 6. Impeller may be damaged - Consult your CLARKE dealer C. AUTOMATIC PUMP WILL NOT STOP 1. Float switch may be prevented from moving to the fully down position. 2. Float switch may be faulty. Consult your CLARKE dealer for advice. D. PUMP STOPS RUNNING 1. Thermal overload has operated. If this condition persists, investigate the cause. Are you attempting to pump liquid which is too heavy for the pump (mud, slurry etc.) 2. Pump has run dry, or float switch has cut in. 3. A foreign object has jammed the impeller. 8

PUMP PERFORMANCE DATA CS85S & CS85SA Outlet Dia.... 1 /25mm Motor Output... 250Watts Motor Speed... 2,800RPM Head Max.... 6M Max. Submersion Depth... 5M Max. Capacity... 80L/min Weight... 3.3/3.5kg Cable... 10M Dimensions*... 155x212mm Part No. CS85S... 7239100 CS85SA... 7239105 *Diameter x Height CS120S & CS120SA Outlet Dia.... 1¼ / 32mm Motor Output... 300Watts Motor Speed... 2,800RPM Head Max. (M)... 6M Max. Submersion Depth... 5M Max. Capacity... 115L/min Weight... 5.2/5.5kg Cable... 10M Dimensions*... 154X238mm Part No. CS120S... 7239110 CS120SA... 7239115 *Diameter x Height CS185S & CS185SA Outlet Dia. 1¼ / 32mm Motor Output 450Watts Motor Speed 2,800RPM Head Max 8M Max. Submersion Depth 5M Max. Capacity 160L/min Weight 5.9/6.2kg Cable 10M Dimensions* 154x238mm Part No. CS185S... 7239120 CS185SA... 7239125 *Diameter x Height 9

CS240S & CS240SA Outlet Dia.... 1½ / 38mm Motor Output... 600Watts Motor Speed... 2,800RPM Head Max.... 11M Max. Submersion Depth... 5M Max. Capacity... 215L/min Weight... 8.7/9.0kg Cable... 10M Dimensions*... 212x290mm Part No. CS240S... 7239130 CS240SA... 7239135 *Diameter x Height CS305S & CS305SA Outlet Dia.... 1½ / 38mm Motor Output... 750Watts Motor Speed... 2,800RPM Head Max.... 14M Max. Submersion Depth... 5M Max. Capacity... 300L/min Weight... 10.7/11.0kg Cable... 10M Dimensions*... 212x290mm Part No. CS305S... 7239140 CS305SA... 7239145 *Diameter x Height 10