BREATHERS & DRYERS: TRANSFORMER BREATHERS

Similar documents
Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment

Breathers: VentGuards Basic protection from moisture and particulate contamination in lubricant and equipment

Index: ** Managing Machine Reliability ** How do Air Breathers work The benefits of Air Sentry Desiccant Breathers Air Sentry Z-Series Breathers

MOISTURE MEETS ITS MATCH

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

Simple And Economical Strategies Designed To Protect Your Fuels,

ADK Filter Drier. Alco Controls. Filter Drier. Features

FILTERS. Accessories. CFA - Filling plugs. CBA-CBB - Air breathers. CSF - Filling plugs with threaded air filter. CLA - Visual level indicators

HEAVY DUTY HEATING & AIR CONDITIONING UNITS & ALL MAKES PARTS. ISSDistribution.com - Call (800)

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

FDB Filter Drier. FDB Filter Drier. Technical Data

Field Engineering Bulletin

BFK Bi-flow Filter Drier

Receiver Driers. Accessories

Model DS1000/DT20 System

SCHROEDER INDUSTRIES 335. Section 9:

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Receiver Driers. Accessories

Technology. The OILMISER Vapor Guard

Receiver Driers. Accessories

Bulk Liquid Filtration

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

Product Information Filters for Process Gases

Facts about Contaminated (Dirty) Diesel Fuel

FILTER DRIERS - SPORLAN

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

Distributed by. Keeping contamination under control. I

The Benchmark for Fuel Cleanliness

Bulk Storage Systems. Clean Organized Safe Efficient Reliable

AIR-TO-AIR HEAT EXCHANGERS MODEL Q2 TECHNICAL SPECIFICATION

RAZOR. RAZOR HVLP Spray Guns

ZX2.2 Gas-insulated medium voltage switchgear

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Des-Case Technical Bulletin Blake Nicodemus. Maintenance of Fire-Resistant Phosphate Ester Fluids

ISSUE DES-CASE PRODUCT CATALOG descase.com

Humidity Cabinet HYGROTHERM

Spaceloft Insulation TECHNICAL GUIDE

SF 6 Gas Reclaimers Zero Emissions. No Substitutes.

Monitoring Water in Lube Oil

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

ISSUE DES-CASE PRODUCT CATALOG descase.com Buy: Phone

Installation of Des-Case breathers at critical ingression points is a cost-effective

HAWLE-AIR RELEASE VALVES

Product data sheet. Series 210, DN (2½ - 6 ) Ordering No PE

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

ECOCLEAN. Compressed Air Filters

General Guide of Lubricants Recycle

CUSTOM CLAMPS. Head Bolt Arrangements. Model Code B3-5 A1 B1 A1HB B1HB S1 HRSGBLPU 30 A1 373 ST

Gas Insulated Metal-clad Switchgear, HMGS!

On-Line Process Analyzers: Potential Uses and Applications

Failure Mode Analysis

ISSUE DES-CASE PRODUCT CATALOG descase.com

C02 SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

C o n t e n t s. SmartBox Overview...2

SILOXA FAKA Gas Cleaning System

485 - NC NO/DA DN

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

perma-tec GmbH & Co. KG Lubrication Systems ZE RTIFIZI E RT E S Lubrication Systems

Buchholz Relay MBP Gas and Oil Actuated Relay

Storage connection with 5 meter long rubber hose DN8, DILO coupling DN8, ball valve DN R050 and five different SF 6

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

CLP - Cartridge Lube Pump

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

PHONE: 937/ FAX:

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

OHB Outdoor sulphur Hexafluoride circuit-breaker

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

ISO 8217:2010 Dr.r.Vis, Viswa Lab

Rainbow 36 V User s Manual

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

MAXIMIZING PUMP RELIABILITY THROUGH PRECISION LUBRICATION

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

They go on, and on, and on...

(FRN, FKN, FSQ) Fusible Resistors

Severe duty cast iron frame motors

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

3535HP LEDs Color Type

OVERVIEW OF RESERVOIR ACCESSORIES

Model PRH FLG. Stainless Steel 1500# Flange High Pressure Regulator (Reducing Valve) 21 Columbus Avenue Garfield, NJ 07026

Call us now: (+44) Fuel Polishing And Filtration Equipment. Page 1

Reliable liquid or simulated winding indication at eye level

Industrial Control Transformers

INSTRUCTION MANUAL #103

BATTERY BANK POWERED AC/DC AIR SAMPLERS

voltage switchgear ZX ABB ZX Family 1

BATTERY BANK POWERED AC/DC AIR SAMPLERS

NXPLUS C Single busbar. Maintenance-free for lifetime

Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

DACouplings, Dry Aviation Couplings According to ISO 45/ MS 24484/STANAG 3105

AIR-TO-AIR HEAT EXCHANGERS MODEL EQ TECHNICAL SPECIFICATION

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

RELIABLE AND EFFICIENT SYSTEMS

Optidew Vision Optical Dew-Point Meter

TotalPac 3 Non interlock Preaction system Pneumatic release

NISTM 2015 New England UST and Shop-Fab Storage Tank Conference

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure

VacuClean Systematic Oil Treatment Patented

Transcription:

The first line of defense against lubricant contamination and dielectric loss The failure or malfunction of many transformers or similar equipment can be directly attributed to the lack of proper control of the level of moisture entering the equipment. It is essential, therefore, that a very low level of humidity is maintained in the air space in the top of the conservator tank to avoid deterioration of the insulating properties of the cooling medium. Transformer breathers provide an economic and efficient means of controling the level of moisture entering the conservator tank during the change in volume of the cooling medium and/or airspace caused by temperature changes. However, with a new moisture content specification of oil being kept at less than 35 ppm moisture (ASTM D-1533 test method), higher performance desiccant than silica gel is needed. ZEOZORB transformer breathers exceed the ASTM D-1533 testing specifications and out perform silica gel breathers by over 75% at average operating temperatures 77 F. In addition, testing shows that if the free air volume above the conservator tank oil is kept very dry, below 100 PPM it will actually liberate and pull moisture from within the transforming insulating lubricant, maximizing performance and life. This dynamic is crucial to optimize operations and maintenance procedures. QUICK FACT: Drytech Transformer breathers reduce the relative humidity levels in a consevator tank to less than 5% RH

Transformer/Dehydrating Breathers Advantages - Extend the life cycle of your lube oil - Minimize component wear, down time and repairs - Protects against high humidity, water condensation, pressure variations - Maintain ISO cleanliness codes - Protects against dielectric loss, mold growth - Extend MTBF and reduce O&M costs Features & Performance 1. Bi-directional valved Air Flow - Air entering the breather is filtered and dried. Each unit is valved to ensure the most efficient flow possible, prolonging the life of the breather. 2. Rugged construction - ZEOZORB transformer breathers are made of robust cast aluminum, or robust ABS plastic and UV resistant polycarbonate tube. 3. ZEOLITE adsorbent - ZEOLITE adsorbent provides up to 28% by weight adsorption and provides clean dry air less than 100 PPM. ZEOLITE also maintains performance in high temperature environments, unlike Silica Gel. 4. Easy to use and ergonomically friendly - All ZEOZORB transformer breathers use a visual sight window to indicate when replacement is necessary. To replace, simply empty the spent breather contents and refill with new desiccant. 5. Protective housings - Optional protective stainless steel and expanded metal housings are available for additional protection 6. Application flexibility - Transformer breathers are offered in a variety of NPT/BSP and flanged connections. See our Adapters section for various fittings and DIN flange applications. 7. Color Indication - When maximum adsorption is reached, the blue indicating ZEOLITE beads will turn from blue to beige, to indicate that a replacement is required.

V, W, X, Y, Z Transformer Breather Drytech Transformer Breathers operate as your first means of protection againt moisture contamination. Transformer breathers take the approach of filtering atmospheric air BEFORE it enters your equipment, rather than trying to take moisture out AFTER it has been introduced into a system. Inhale Cycle 1. Air will enter the base of the breather 2. As the air is drawn into the breather, the moisture is adsorbed 3. This dry air will then flow upward and into the tank or reservoir being protected 4. The very dry air will blanket the free air volume inside the tank and will liberate moisture from within the tank Exhale Cycle 5. Air will be pushed down through the top of the breather 6. The air will flow back down through the desiccant and out of the bottom of the breather Technical & Dimensional Series W-Z Model Dim. B ZEOZORB Transformer Breathers R R1 R2 V W X Y Z 6.22 (158mm) 9.84 (250mm) 13.85 (352mm) 14.76 (375mm) 21.85 (555mm) 28.94 (735mm) 19.09 (485mm) 25.39 (645mm) Dia. A Dim. C Transformer Rating 10.03 (255mm) diameter 4.25 (108mm) diameter 3/4 FNPT, see adapters for other configurations < 1.25mVA Max Transformer Oil Quantity 1,500 Desiccant weight 2.2 (1kg) Unfilled weight 4.7 (2.1kg) 3 mva 3,000 3.3 (1.5kg) 5.8 (2.6kg) 13.97 (355mm) diameter V,W, & X uses 3/4 FNPT, Y&Z uses 1 FNPT 6 mva 4,750 9 mva 11,350 4.4 (2kg) 6.9 (3.12kg) 30 mva 60 mva 100 mva 180 mva 22,700 34,050 45,450 68,150 13.2 (6kg) 17.6 (8kg) 22 (10kg) 24.25 (11kg) 30.8 (14kg) 39.7 (18kg) 7.2 (10kg) 10.5 (4.75kg) 13.3 (6kg) 17.6 (8kg)

R, R1, R2 Transformer Breather Dia. A 3. This now dry air will exit the breather into the transformer reservoir Dim. C The desiccant will provide a color change from blue to beige, indicating the desiccant is saturated and should Dim. B 2. As the air is drawn into the breather, the moisture is adsorbed. 1. Air will enter the base of the breather Drytech Transformer Breathers operate as your first means of protection againt moisture contamination. Transformer breathers take the approach of filtering atmospheric air BEFORE it enters your equipment, rather than trying to take moisture out AFTER it has been introduced into a system. Inhale Cycle 1. Air will enter the base of the breather Series R 2. As the air is drawn into the breather, the moisture is adsorbed Dim. B Model 3. This dry air will then flow upward and into the tank or reservoir being protected 4. The very dry air will blanket the free air volume inside the tank and will liberate moisture from within the tank ZEOZORB Transformer Breathers R R1 R2 6.22 (158mm) 9.84 (250mm) 13.85 (352mm) Dia. A Dim. C Transformer Rating 4.25 (108mm) diameter 3/4 FNPT, see adapters for other configurations < 1.25mVA Exhale Cycle 5. Air will be pushed down through the top of the breather Max Transformer Oil Quantity 1,500 Desiccant weight 2.2 (1kg) 6. The air will flow back down through the desiccant and out of the bottom of the breather Unfilled weight 4.7 (2.1kg) 3 mva 3,000 3.3 (1.5kg) 5.8 (2.6kg) 6 mva 4,750 4.4 (2kg) 6.9 (3.12kg)

Transformer Breather Adaptors BLD10090 3/4 MBSP to 1/2 FBSP BLD10915 3/4 MBSP to 1 MBSP BLD10914 BLD10995 3/4 MBSP to 2 FBSP 3/4 MBSP to 1/2 MBSP BLD12308 BLD10916 3/4 MBSP to 1-1/4 FBSP 3/4 MBSPP to 1/4 MBSPP BLD10841 3/4 FBSP to 1/2 MBSP BLD12307 3/4 MBSPP to 3/8 MBSPT QUICK FACT: Over 70% of lubrication failures are caused by surface degredation, of which 50% is from mechanical wear (particulates) and 20% is from corrosive wear (water)

Transformer Breather Adaptors BLD12214 BLD12305 BLD11000 Adaptor 3/4 MBSPP to Adaptor 3/4 MBSPP to 1-1/2 MBSPT 3/4 MBSPP BLD10930 Triangular adaptor flange w/ 3/4 MBSP to DIN SPEC 42562 BLD11915 BLD11103 BLD10996 Flanged elbow adaptor to DIN SPEC 42567 BLD12213 BLD10090 DIN 42567 flanged adaptor straight to MBSP Plate adaptor with elbow to 3/4 MBSP 1 PNG flange adaptor to 3/4 MBSP 3/4 MBSPP adaptor to DN40 PN6 flange QUICK FACT: ASTM D-1533 test method states that moisture content of conservator tank lube oils should be kept under 35 PPM (parts per million) moisture

Switchgear SF6 Drytech Inc. offer a range of desiccant solutions to combat the problems of moisture within SF6 filled High Voltage switchgear enclosures. Sulphur hexafluoride (SF6) is used as an insulating gas in transmission and distribution equipment such as switchgear and circuit breakers. In order to maintain SF6 insulation properties and to reduce the formation of unwanted secondary decomposition products, the amount of water vapor in the gas insulated system (GIS) should be kept to a minimum. If moisture levels are not kept to a minimum then formation of acid by-products, such as Hydrogen fluoride, Sulphur dioxide, Sulphur fluoride, & Thionyl flouride can be generated. This reaction may yield hydrofluoric acid. Hydrofluoric acid is extremely corrosive and will react with electrical equipment components. Moisture limit recommendations vary between equipment manufacturers but typically should be around -45 C to -25 C dewpoint (atmospheric) In order to maintain these low moisture levels a passive desiccant solution must be included within the cabinet. Drytech suggests that a large pore molecular sieve be used as this has the ability to co-adsorb both moisture and arcing by-products. DH/D1110-11 High Voltage Enclosures High voltage motor protection desiccators provide protection against corrosion, dampness, and contamination in electrical, high voltage motors and switchgear. These desiccators incorporate a humidity which monitors saturation and indicates when desiccant change or cartridge replacement is required. They are blue when the desiccant is dry and turn to pink when the maximum amount of moisture has been adsorbed DH/D1099 DH/D1078 DH/D6088

ZEOZORB Desiccant Drytech Inc. Transformer breathers are filled with our high performing ZEOZORB desiccant which changes color from blue to beige as it becomes saturated with water vapor. Desiccant Adsorption at Temperature and Dewpoint 50 ASTM D-1533 specifications state that transformer conservator tank oil should be kept below 35 ppm (parts per million) water vapor. The current industry standard desiccant Silica Gel, can not meet this standard, which is why we use our ZEOZORB desiccant, which is capable of conditioning air below 10 ppm. Drytech Inc. Transformer breathers are designed to enable the easy and quick replacement of the desiccant charge. When the color change from blue to beige has reached the level shown on the label, the desiccant should be replaced. Now that the old type oil-seal has been replaced by inward and outward relief valves, the replacement of the desiccant charge is the only maintenance activity required. 10 Cdp (12,317 ppm) Silica Gel 0 Cdp (6,092 ppm) 40-10 Cdp (2,847 ppm) 35 % Moisture adsorbed Active Replace 45 ZEOLITES -40 Cdp (188 ppm) 30 25-10 Cdp (2,847 ppm) 20 15-20 Cdp (1,246 ppm) 10 0 Cdp (6,092 ppm) z EOZORB -30 Cdp (506 ppm) 5-40 Cdp (188 ppm) 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Air temperature C The isotherm above illustrates the performance benefits of ZEOZORB desiccant, especially at higher temperatures. Silica Gel s adsorption capacity % drops off drastically as temperatures increase, whereas ZEOZORB maintains its efficiency. In addition, ZEOZORB can achieve a much lower dew point, less than 10 PPM. Ordering & Delivery To order one of our Transformer Breathers, please contact our commercial sales administrator, Cliff Jones, jonesc@drytechinc.com. Typical questions about the application will include: 1. Size of conservator tank 2. Tank pipe connection 3. Max flow rate 4. Desired life of desiccant Drytech Inc. 54 Wrightstown-Cookstown Road Cookstown, NJ 08511 Tel: 609-758-1794 Fax: 609-758-1774 Email: jonesc@drytechinc.com