An important type of protective

Similar documents
NHP SAFETY REFERENCE GUIDE

Session Four Applying functional safety to machine interlock guards

SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

BL6009 Operation Contact rrangement or Shaft movement /12 / / mm contact Open contact closed Principle of Operation Interlockin

Safety handles P-KUBE line

SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

Safety switches with solenoid and separate actuator

Safety Interlock Switch with Guard Door Locking. Narrow profile enables mounting to 2 in. square tubing or in applications with space restrictions

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

NHP SAFETY REFERENCE GUIDE

Sense7-series Non-contact coded safety switch

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Programmable Logic Controller. Mat Nor Mohamad

Heavy-Duty Safety Interlock Switch with Guard Door Locking

Safety switches with solenoid and separate actuator

MKey9-series Safety Interlock Switch with Guard Locking

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

Safety Interlock Switches

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Safety Switches NP GP TP. More than safety.

D o o r I n t e r l o c k s

CAUTION CM-SE CM-S21 CM-S41

Ch 4 Motor Control Devices

Modern Safety Systems and Advanced Fluid Power Solutions

National Enduralube Bearings

F3S-TGR-KHL1/-KHL3/-KHL3R

AZM300 More than just a solenoid interlock

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Solenoid interlock AZM 200 The non-contact interlock.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Input, Control and Processing elements

Protecting People, Industry and Productivity

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

ABB Jokab Safety Safety switches & emergency stops Food, beverage, pharmaceutical & chemical industries

[You may download this article at: ]

UNI EN ISO EN

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Safety Control HR1S-AC. Safety Relay HR1S-AC

MECHATRONICS LAB MANUAL

SG-B1 SERIES / SG-A1 SERIES

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

1. Safety practices General Introduction Standards...3

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

CTi Automation - Phone: Fax: Web:

Electrical Control System Components Basics of Magnetic Control :

Design Standard. Purpose: Design Standard:

Self-protected Combination Starters System PKZ 2-SP

HS1C Interlock Switches with Solenoid

MAGNETIC MOTOR STARTERS

Automation is the techniques and equipment used to achieve automatic operation or control.

Hinge Wing Safety Interlock Switches

Hinge Wing Safety Interlock Switches

SOFT TOUCH A NEW STANDARD FUNCTION FOR UNITROL SOLUTION

Position Switches according to EN 50041

Limit Switches according to EN 50041

Limit Switches according to EN 50041

SECTION B1: MACHINE COMPONENTS

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

The distinguishing features of the ServoRam and its performance advantages

Factor 1 Sensors: The Evolutions of Metal Detection A WHITE PAPER

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Emergi-Lite EMEX central power supply solutions

Electrohydraulics Basic Level Textbook TP 601

SECTION B: SYSTEM OPERATING COMPONENTS

Safety switches with solenoid and separate actuator

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

16000SIII Automatic Grease System

Trip Wire. Category: Physics: Electricity & Magnetism. Type: Make & Take Rough Parts List:

Hinge Wing Safety Interlock Switches

Safety door-handle system STS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Selecting & Integrating Safety Exhaust Valves White Paper

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

RELAYS. Figure Relay construction.

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

EXPERIMENT 5 (a) PRESSURE, PROXIMITY AND MAGNETIC FIELD SENSORS

Improving predictive maintenance with oil condition monitoring.

CENTRIC CENTRIFUGAL CLUTCHES

How New Angular Positioning Sensor Technology Opens A Broad Range of New Applications. WhitePaper

INSTALLATION 8310/8320

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

Crane and Hoist Solution Guide. The Advantage of Experience

WHITE PAPER. SVM4001 Series standstill monitor. Stop everything! Standstill monitors add sensorless safety features to motor-driven machinery

Components for safety applications

Dual Power. Protection. Protection

Power Switching Principles

LEM Transducers Generic Mounting Rules

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Solid Dielectric, Single Phase Recloser

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

HS6B Series Subminiature Interlock Switch

Heavy Duty Ball Screw Linear Actuators

Electronic Ballast EVG 2000-T

Transcription:

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Interlocking Principles and Devices n important type of protective device is a safety interlock switch which interlocks a guard door with the power source of the hazard. When the guard door is opened, the power is isolated, ensuring that the machine is safe when the operator requires access. There are many variations of interlock switches, each with its own characteristics. It is important to ensure that the type of device chosen is correct for its application. Later in this chapter we will look at a series of logical decisions leading to the exact choice of device to be used. First, let's familiarize ourselves with some of the general features and requirements which make devices suitable for interlocking duties. Standards The International Standard ISO 14119 - Interlocking devices associated with guards gives guidance. It is intended to be used in conjunction with IEC 60947-5-1 for electromechanical switches. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Reliability n interlock switch must operate reliably even under extreme conditions and rough treatment. The operating mechanism should be kept as simple as possible and all materials used in its manufacturer should be of the highest quality. The design should ensure that component wear is kept to a minimum. The mechanism should be enclosed in a strong, sealed case. Security The security of an interlock switch is dependent on its ability to withstand attempts to cheat or defeat the mechanism. n interlock switch should be designed so that it cannot be easily defeated. In some circumstances, personnel may be tempted to override the switch in some way. Information concerning the use of the machine, gathered at the risk assessment stage, will help to decide whether this is more or less likely to happen. The more likely it is to happen, then the more difficult Fig. 6.1 it should be to override the switch or system. The level of estimated risk should also be a factor at this stage. Switches are available with various levels of security ranging from resistance to impulsive tampering, to being virtually impossible to defeat. It should be noted at this stage, that if a high degree of security is required, it is sometimes more practical to achieve this by the way in which the switch is mounted. For example, if the switch is mounted as in Figure 6.1 with a covering track, there is no access to the switch with the guard door open. The nature of any cheating prevention measures taken at the installation stage will depend on the operating principle of the switch. 51

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 52 Positive Mode Operation (also referred to as direct operation) ISO 12100 explains that if a moving mechanical component inevitably moves another component along with it, either by direct contact or via rigid elements, these components are said to be connected in the positive mode. With single mechanical type interlocking switches, when the guard is opened the movement of the guard should be connected in the positive mode to the Safety-Related contacts of the switch. This ensures that the contacts are physically pulled apart or force disconnected by the movement of the guard. The switch should not rely solely on spring pressure to open the contacts, as the force exerted may not be able to overcome sticking or welded contacts. There is also the possibility that the switch could fail to danger if the spring breaks and there is no other way to open the contacts. Figure 6.2() shows a typical negative (or non-positive) mode operating system. There is no direct link between the guard door and the safety contacts, so the system relies entirely on spring pressure to open the contacts. In the event of spring failure, contact weld or sticking, the system will fail to danger and is therefore unacceptable. This type of system is easily defeated by pushing the plunger while the guard is open. Even worse, the switch can be tripped accidentally by an operator leaning onto or into the machine while the guard is open. Figure 6.2(B) shows a simple example of positive mode operation giving forced disconnection of the contacts. cam is mounted on the door hinge so that it directly operates the contacts whenever the guard door is open. Spring pressure can only close the contacts when the guard is fully closed. ny spring breakage will only result in a failure to a safe condition. Enclosure US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Fig. 6.2 Safety Operating status Contact opening method pplicable contact () Negative operation Never use negative-operation switches alone in safety applications. Category B or 1 (using approved parts) Normal operation Contacts closed (door closed} Contacts open The positive mode operation principle shown in Figure 6.2 is used wherever it is relevant in safety interlock switches. They also avoid any possible abuse by enclosing the contact block and cam in a bnormal operation a) No reset due to contact welding b) No reset due to spring damage Opened by built-in spring NO contacts (B) Positive operation Positive-operation switches are recommended when used alone as the switches offer a higher level of safety than negative-operation switches. Normal Operation Contacts closed (door closed) Contacts open B, 1, 2, 3, 4 bnormal operation a) Contact not open due to abrasion b) Contact not open due to improper cam position Opened directly by externally operating unit like cam or dog. NC contacts (O) strong and secure enclosure. This means that the cam and the contact block cannot become separated and it is impossible to defeat the switch by cutting another slot in the cam.

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Fitness for Purpose s a minimum, all designs and materials must be able to withstand the expected operating stresses and external influences. Other Safety Principles For non-mechanical devices, there is usually no physical contact between the switch and actuation method. Therefore, positive mode operation cannot be used as the way of ensuring the switching action. Other methods can be used and are explained in the next section. Oriented Failure Mode With simple devices, we can use components with an oriented failure mode as explained in ISO 12100. This means using components in which the predominant failure mode is known in advance and always the same. The device is designed so that anything likely to cause a failure will also cause the device to switch off. n example of a device using this technique is the M Series non-contact magnetically actuated interlock switch. The contacts are protected by being in series with an internal non-resettable overcurrent protection device. ny overcurrent situation in the circuit being switched will result in an open circuit at the protection device which is designed to operate at a current well below that which could endanger the Safety-Related contacts. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Fig. 6.3 Duplication (also referred to as Redundancy) ISO 12100, 4.12.3 explains that if components which are not inherently safe are used in a design and they are critical to the safety function, then an acceptable level of safety may be provided by duplication of those components or systems. In case of failure of one component, the other one can still perform the function. It is usually necessary to provide monitoring to detect the first failure so that, for example, a dual channel system does not become degraded to a single channel without anybody being aware of the fact. ttention also needs to be given to the issue of common cause failures. Fig. 6.4 WITHOUT GURD LOCKING MECHNICL DEVICES CONTROL INTERLOCKING NON-CONTCT DEVICES Typical Forms of Interlocking Devices VOLTGE CROSSOVER GLVNIC ISOLTION BRRIER ny failure which will cause all duplicated components (or channels) to fail at the same time must be protected against. Suitable measures may include using diverse technologies for each channel or ensuring an oriented failure mode. Galvanic Isolation On contact blocks with two sets of contacts a galvanic isolation barrier is required if it is possible for the contacts to touch each other back-to-back in the event of contact weld or sticking (Figure 6.3). WITH GURD LOCKING UNCONDITIONL GURD UNLOCKING POWER INTERLOCKING CONDITIONL GURD UNLOCKING 53

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 54 Typical Forms of Interlocking Devices In the broadest terms there are two basic types of electrical interlocking systems: Power interlocking - The power source of the hazard is directly interrupted due to the opening of the guard. Control interlocking - The power source of the hazard is interrupted by the switching of a circuit which controls the power switching device. The following text deals with the KEY TRPPED MIN SUPPLY ON MCHINE IS RUNNING. ELECTRICL SUPPLY IS ON. CCESS DOOR IS LOCKED. Fig. 6.5 KEY TRPPED MIN SUPPLY ON MCHINE IS RUNNING. ELECTRICL SUPPLY IS ON. CCESS DOOR IS LOCKED. Fig. 6.6 US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 interlocking of electrical power supplies as this is by far the most common requirement, but the same basic principles can be applied to hydraulic and pneumatic systems. Power Interlocking The movement of the guard is interlocked with the direct switching of the power to the hazard. For equipment using low voltage and power, most types of interlock switches can be used for power ELECTRICL SUPPLY LOCKED OFF MCHINE IS NOW STOPPED ND THE ELECTRICL SUPPLY HS BEEN ISOLTED. CCESS DOOR CN NOW BE OPENED. WHEN DOOR IS OPEN, KEY IS TRPPED. ELECTRICL SUPPLY LOCKED OFF MCHINE IS NOW STOPPED ND THE ELECTRICL SUPPLY HS BEEN ISOLTED. CCESS DOOR CN NOW BE OPENED. WHEN DOOR IS OPEN KEY IS TRPPED KEY B IS TKEN INTO THE GURDED RE TO ENSURE THE DOOR CNNOT BE LOCKED BY THIRD PRTY. interlocking. But because most industrial machinery uses a relatively high power three phase supply, we need specially designed power interlocking systems with the power interrupting switch capable of handling and breaking the load reliably. The most practical method of power interlocking is a trapped key system such as the Prosafe system (see Figure 6.5). The power isolation switch is operated by a key which is trapped in position while the switch is in the on position. When the key is turned the isolation switch contacts are locked open (isolating the power supply) and the key can be withdrawn. The guard door is locked closed and the only way to unlock it is by using the key from the isolator. When this key is turned to release the guard locking unit it is trapped in position and cannot be removed until the guard is closed and locked again. Therefore, it is impossible to open the guard without first isolating the power source and it is also impossible to switch on the power without closing and locking the guard. This type of system is extremely reliable and has the advantage of not requiring electrical wiring to the guard. The main disadvantage is that because it requires the transfer of the key every time, it is not suitable if guard access is required frequently. Whenever whole body access is required, the use of a personnel key is recommended (see Figure 6.6 and 6.7). The Prosafe range is available in double key versions to meet this requirement. The use of a personnel key ensures that the operator cannot be locked in the guarded area. The key can also be used for robot teach mode switches, inch mode controls etc. By using double key locking units and keys with different codes together with a key exchange unit, complex systems

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Fig. 6.7 can be formed. Besides ensuring that the power is isolated before access can be gained, it is also possible to use the system to enforce a pre-defined sequence of operation. Required Features Because the safety of this type of system depends on its mechanical operation, it is critical that the principles US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Fig. 6.9a (Top) Double access guard doors interlocked with the Power Isolation Switch. Key is trapped in the isolation switch. Both B keys are trapped in a Key Exchange Unit. Power is ON and there is no access available to the machine through the locked guard doors. Fig.6.9b (Bottom) Rotate and remove Key from power isolator. Power is then OFF. To gain access through guard doors Key is inserted and rotated in Key Exchange Unit. Both B Keys are then released for guards locks. Key is trapped preventing power being switched on. Two C Keys are released from the guard door locks for use in the next sequence step or as personnel keys. and materials used are suitable for the expected demand made on them. If an isolation switch is part of the system, it should have positive mode operation and it should satisfy the requirements of the relevant parts of IEC 60947. The integrity and security of the system revolves around the fact that under certain conditions the keys are trapped in place, therefore two basic features need to be ensured: 1. The lock can only be operated by the dedicated key. This means that it should not be possible to cheat the lock by using screwdrivers etc., or defeat the mechanism by mistreating it in any straightforward manner. Where there is more than one lock on the same site it also means that the specifying of key codes must in itself prevent any possibility of spurious operation. 2. It is not possible to obtain the key in any way other than the intended manner. This means that (for example) once the key is trapped, any excessive force applied to it will result in a broken key as opposed to a broken lock. Control Interlocking Control interlocking is the most commonly used method of interlocking. n interlock switch is attached to the guard to detect movement and open the switch contacts whenever the guard is not fully closed. The contacts are connected via a control circuit to the hazard source primary control element (contactor). So first, let's look at the different types of devices suitable for control interlocking (Figure 6.4). The first major distinction is between devices without guard locking and with guard locking. 55

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 56 Interlock Switches Without Guard Locking These devices do not restrict access and the guard door can be opened at any time; but as soon as it is opened the switch isolates the power to the hazard via the contactor control circuit. If the hazard always ceases immediately, then the requirements are satisfied because the operator cannot reach the parts while they are dangerous. If the hazard does not cease immediately, there is a possibility that an operator can reach it while it is running down and still dangerous. To avoid this unacceptable situation, there are three alternatives as illustrated in Figures 6.8, 6.9 and 6.10. Note: The integrity of the braking device needs to be considered both in terms of fault resistance and wear characteristics. If a precise calculation is required, the International Standard ISO 13855 deals with the positioning of protective equipment with respect to approach speeds of parts of the human body. t present it does not specifically cover interlocked guard doors, but its principle for the positioning of other safety devices based on approach speed and machine stopping time can reasonably be extrapolated to cover interlocked guard doors without guard locking. The next subdivision for interlocking devices without guard locking is their designation as mechanical actuation or non-contact actuation. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 1 2 3 D.C. INJECTION BRKE S Fig. 6.8 Use an interlocking device with guard locking to prevent guard opening before the hazard has ceased. Fig. 6.9 Install some form of braking device to achieve a fast stop. Fig. 6.10 The separation distance between the hazard and the guard door should be such that it takes longer for the operator to reach the hazard than it does for the hazard to stop.

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Mechanically ctuated Devices With these devices the guard door is linked mechanically to the control circuit contacts of the switch using positive mode operation. There are three main types of mechanical actuation. These are: ctuator Operated With the tongue interlock switch, as shown in Figure 6.11, the guard mounted actuator opens or closes the contacts via the internal mechanism. Features: The actuator and mechanism are designed to prevent easy cheating of the switch. These devices are straightforward to install and are very reliable. They can be used on sliding, hinged and lift-off guards and because of their versatility they are one of the most commonly used types of interlock switches. For consideration: The guard mounted actuator needs to remain reasonably well aligned with the entry hole in the switch body. ctuator operated switches can be difficult to clean thoroughly. This may be a problem in industries such as food manufacturing and pharmaceuticals. Hinge Operated ctuation The device is mounted over the hingepin of a hinged guard. The opening of the guard is transmitted via a positive mode operating mechanism to the control circuit contacts (Figure 6.12). Features: When properly installed, these types of switches are ideal for most hinged guard doors where there is access to the hinge center line. They can isolate the control circuit within 3 of guard movement and they are extremely difficult to defeat without dismantling the guard. For consideration: Care must be taken on very wide guard doors, as an opening movement of only 3 can still result in a significant gap at the opening edge. It is also important to ensure that a heavy guard does not put undue strain on the switch actuator shaft. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Fig. 6.11 Tongue Operated ctuation Fig. 6.12 Hinge Operated ctuation 57

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 58 Cam Operated ctuation This type of arrangement usually takes the form of a positive mode acting limit (or position) switch and a linear or rotary cam. It is usually used on sliding guards and when the guard is opened the cam forces the plunger down to open the control circuit contacts (see S2 in Figure 6.13). Features: The simplicity of the system enables the switch to be both small and reliable. For consideration: It cannot be used on hinged or lift-off guards. It is extremely important that the switch plunger can only extend when the guard is fully closed. This means that it may be necessary to install stops to limit the guard movement in both directions. It is necessary to fabricate a suitably profiled cam which must operate within defined tolerances. The guard mounted cam must never become separated from the switch as this will cause the switch contacts to close. This system can be prone to failures due to wear especially in the presence of abrasive materials or with badly profiled cams. It is often advisable to use two switches as shown in Figure 6.13. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Non-Contact (Non-Mechanical) ctuation With these devices, the guard door is linked to the control circuit contacts of the switch via a magnetic or electronic field. To make these types of devices suitable for interlocking applications, they must incorporate enhancements to ensure proper operation. Because they do not have the benefit of true mechanical positive mode operation, they must have other ways of ensuring that they cannot fail to a dangerous condition. This is achieved by either oriented failure mode principles or by the use of duplication and monitoring. The M Series uses the principle of oriented failure mode. Due to the use of special components, the only safety critical fault likely to occur would be a welding of the reed contacts due to excessive current being applied to the switch. s shown in Figure 6.14, this is prevented by the non-resettable overcurrent protection device. There is a large margin of safety between the rating of this device and the reed contacts. Because it is non resettable, the switch should be protected by a suitably rated external fuse. CTUTION FIELD SWITCH IN SELED CSE Fig. 6.14 Fig. 6.13 Cam Operated ctuation - 2 Switches S1 Specially profiled heavy duty reed contacts Negative operation Negative operation Contacts closed (door closed) S1 Positive operation It is important that the switch is only operated by its intended actuator. This means that ordinary proximity devices which sense ferrous metal for example are not appropriate. The switch should be operated by an active actuator. S2 S2 Positive operation Contacts open CONFIGURED MGNETIC CTUTOR IN SELED CSE S2 S1 S2 S1 Non-resettable overcurrent protection device External fuse suitably rated to protect interlock device

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com The security can be further improved by coding such as on the CM Series. This switch uses the same oriented failure mode principle as the M Series but has higher security due to its coded actuator and sensor. Features: Non-contact devices are available in fully sealed versions which makes them ideal for hygiene sensitive applications, as they can be pressure cleaned and have no dirt traps. They are extremely easy to install and have a considerable operating tolerance, which means that they can accept some guard wear or distortion and still function properly. Solid-state non-contact door switches are now available and offer increased performance for certain environmental conditions such as vibration. The D40 non-contact switch is a solid state switch that works on the principle of Hall Effect. Up to thirty switches can be connected to a single G9SX-NS controller and be Swinging doors US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 Fig. 6.15 monitored to category 3 (see Figure 6.16). For consideration: For the simpler actuation types, if security is an important issue, it may be necessary to install them as shown in Figure 6.15 so that they cannot be accessed while the guard is open. It is important, particularly for the non-coded types, that they are not subjected to extraneous interference by fields which are the same as their operating principle. Interlocking Switches With Guard Locking These devices are suited to machines with run down characteristics but they can also provide a significant increase in protection level for most types of Sliding doors Up to 30 Switches Fig. 6.16 Up to 30 D40 switches can be monitored to Category 3. HZRD RE STOP SWITCH CTUTOR SLIDING GURD GURD OPEN - MCHINE STOPPED - GURD COVERING SWITCH machines. They provide interlocking of the hazard power source with guard movement and also prevent the opening of the guard until it is safe to do so. These devices can be divided into two types: Unconditional and conditional guard unlocking. Unconditional Guard Unlocking These devices are manually operated and the guard can be opened at any time. handle or knob which releases the guard lock also opens the control circuit contacts. On a device such as a time delay bolt switch, a time delay is imposed (Figure 6.17). The bolt which locks the guard in place also operates the contacts. The bolt is withdrawn by turning the operating knob. The first few turns open the contacts but the locking bolt is not fully retracted until the knob is turned many more times (taking up to 20 secs.). The Prosafe trapped key system (see power interlocking section) can be used to provide unconditional guard locking. Features: These devices are simple to install and they are extremely rugged and reliable. The time delay bolt switch is suitable mainly for sliding guards. 59

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 60 Fig. 6.17 For consideration: The stopping time of the hazard being guarded must be predictable and it must not be possible for the bolt to be withdrawn before the hazard has ceased. It must only be possible to extend the bolt into its locked position when the guard is fully closed. This means that it will usually be necessary to install stops to restrict the travel of the guard door. Conditional Guard Unlocking With these devices, the guard can only be opened on receipt of a signal showing that: the contactor is OFF. a pre-set time interval has elapsed or alternatively that dangerous motion has ceased. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 These signals are usually derived from the auxiliary contacts of a safety monitoring relay with OFF-Delay outputs, or a Stop Motion Detection Monitoring Relay such as the G9SX-SM. They provide interlocking of the hazard power source with guard movement and also prevent the opening Guard mounted switch actuator Lock release solenoid Safety control contacts Lock or unlock indication contacts Door open or closed contact Fig. 6.18 The D4NL solenoid operated locking switch of the guard until it is safe. Because an externally generated signal is required for lock release, it makes them particularly suitable for use with PLC or other programmable electronically controlled machines. The usual type of interlocking device for these purposes is a solenoid-operated locking switch such as the TL4019, TL4024, D4BL, D4NL, D4GL OR D4JL. Figure 6.18 shows the basic components common to the D4NL solenoid operated locking switches. For less frequently accessed applications, the Prosafe trapped key system (see power interlocking section) can be configured to operate in this way. In the example shown in Figure 6.19, the hazard ceases as soon as power is isolated by switching the machine off at the normal controls. The guard cannot be opened until the contactor has switched off. Once the guard is opened the control circuit contacts ensure that the contactor

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com cannot be re-energized until the guard is closed and locked. With the configuration shown in Figure 6.20 the switch will not release the guard until the contactor is off and a pre-set time interval has elapsed. The time range can be set from 0.1 seconds to 30 seconds. The longest stopping time of the machine should be predictable and constant. It should not rely on braking methods which may degrade with use. The system shown in Figure 6.20 will not apply power to the solenoid of the switch until a specified period of time has elapsed. This "Delayed ON" function of the SR209 controller is used with "power to unlock" solenoid locking switches. Figure 6.21 shows a configuration where the switch will not release the guard until the contactor is off and all motion has stopped. US Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 SOLENOID LOCKING INTERLOCK SWITCH (D4JL) 41 51 63 LOCK RELESE SOLENOID LTCHING E-STOP E1 SOLENOID LOCKING SWITCH E2 G9SX-SM or SR125SMS45 STOP MOTION SENSING UNIT 1 Z1 Z2 Z3 E1 E2 MOMENTRY STOP 42 11 52 21 64 33 1 SR209 2 M RESET K2 K1 K1 DELYED ON CONTCT 13 SOLENOID 14 2 12 22 34 SFETY CIRCUIT INDICTION CIRCUIT Shown in machine run condition. Simplified circuit shown for clarity with no emergency stop. Fig. 6.19 Fig. 6.20 Fig. 6.21 STRT STOP K1 K2 EXTRNL DEVICE MONITORING K1 SFETY CONTCTS STRT STOP SOLENOID LOCKING SWITCH 61