GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02 5

Similar documents
Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

Preparation: Remove fuel tanks if vehicles are to be burned and chock wheels to prevent unexpected movement

Emergency Services Guidance for Competition Electric Vehicles

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire

Procedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November January 2005

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

SCENARIO 8. Propane Fueled Delivery Truck Fire INCIDENT OVERVIEW

GRANDVIEW TOWNSHIP FIRE DEPARTMENT STANDARD OPERATING GUIDELINES. #333 Vehicle Fire Date Issued: 01/01/2014 Date Last Revised: 01/01/2014

Chapter 42. Objectives. Objectives 01/09/2013. Gaining Access and Patient Extrication

SCENARIO 16 Overturned MC-331 Cargo Tank Truck

Special Post Crash Safety Considerations

Hybrid & Electric Cars Guidance for organisers of Speed events

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

The information in this guide will allow response to emergencies involving Balance Hybrid E450 vehicles.

Travis County Emergency Services District #1 Standard Operating Guidelines

2.3. Priority Responses recognized by the Derby Fire Department will be as follows:

SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION

Apparatus Placement. Was this fire apparatus placed properly?

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

YORK COUNTY FIRE TRAINING EMERGENCY VEHICLE DRIVER REFRESHER

EXAMPLE STANDARD OPERATING PROCEDURE EXPOSURE PREVENTION AND DECONTAMINATION

Log Splitter. Owner/Operator Manual. Models HCWP1-26

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

SECTION 14: AERIAL LIFT PROGRAM

COLLIER COUNTY EMS / FIRE DEPARTMENT STANDARD OPERATING GUIDELINES

Positioning Aerial Apparatus By: Joe Kroboth, III, PE, CFPS Emergency Services Instructor MFRI, Western Maryland Regional Office

Apparatus Riding Assignments

STANDARD OPERATING PROCEDURES. ELECTRICAL HAZARDS SAFETY PROCEDURES PURPOSE: To provide safety procedures for the removal of electric meters,

Fire Engine Information

OPERATING PROCEDURES FOR ROADWAY INCIDENTS

C>r>E: X EMERGENCY RESPONSE GUIDE

WHAT YOU DON T KNOW COULD BURN YOU! How To Avoid The Unknown Dangers Of Handling Fuel In Your Shop

C>r>E: X EMERGENCY RESPONSE GUIDE

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

SECTION: 1503 Use of Lights & Sirens SUPERCEDES/RESCINDS: All Prior EFFECTIVE DATE:

ESCAPE HYBRID EMERGENCY RESPONSE GUIDE. Version 1.0

CLEARWATER FIRE & RESCUE TRAINING BUREAU

Propane torch. Model Assembly And Operation Instructions

C>r>E: s EMERGENCY RESPONSE GUIDE

Electrical Safety. Electricity. Safety. Division of Workers Compensation HS01-013B(02-14)

2006/2007 ESCAPE HYBRID OR MARINER HYBRID

Principles of Vehicle Extrication

2011 ESCAPE HYBRID MARINER HYBRID EMERGENCY RESPONSE GUIDE

UNIT CAD CLASSIFICATION DEFINITIONS. Northampton County Emergency Management Services

EMERGENCY RESPONSE GUIDE

Installation Instructions for Aux 101 Kit A044Z055

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

LABORATORY SAFETY SERIES: Electrical Safety

Safety Manual Captive Bolt Dispatch Tool

Guidance on safe procedures for staff and students in respect of road traffic incidents and breakdowns

INFORMATION FOR FIRE SERVICES ON LPG / AUTOGAS VEHICLES

2.3.2 Hydrant Maintenance

Fairview Fire District

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

"ELECTRICAL SAFETY IN THE WORKPLACE"

RAPID INTERVENTION TEAM STANDARD OPERATING PROCEDURES

Dispatching Apparatus and Personnel

Developed by Engineer Bobby Bartlett February 2012

CLEARWATER FIRE & RESCUE TRAINING BUREAU

Defensive Driving Policy

Position Number Community Division/Region Yellowknife North Slave

Outsource Practices & Policies OPP

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

Airport Operating Standard. Spill Prevention and Response

Vehicle Extrication. by Dave Dalrymple

Protecting Service Technicians The Basics of Hybrid Safety for the Service Manager

Newmont USA Ltd. Genesis Mine June 6, 2009

2018 Honda Clarity Plug-In Hybrid Emergency Response Guide

BUCKET TRUCK SAFETY EQUIPMENT

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 8 Extrication Equipment Revised

Driving Fire Apparatus Safely

Holden Volt Emergency Response Guide 9/11/12

MITSUBISHI i-miev Emergency Response Guide. Lithium-Ion Battery Electric Vehicle. Copyright 2014, Mitsubishi Motors North America, Inc.

2018 Honda Accord Hybrid Emergency Response Guide

Lesson 5 4-Hour Version Slide: 4H-90

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Emergency Decontamination

STANDARD OPERATING GUIDELINES

Installation Instructions for Load Management Kit A051C329

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

GENERAL HOUSEKEEPING. 1. Are all aisles, passageways, stairways and stairwells kept clear of tools, hoses, and trash?

Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office

Vehicles shall be operated in compliance with all traffic laws of the State of Ohio, including those Sections pertaining to emergency vehicles.

Honda Clarity Electric Emergency Response Guide

Guidelines For the MITIGATION OF ACCIDENTAL DISCHARGES OF MOTOR VEHICLE FLUIDS (NON-CARGO) APPROVED 6/25/04

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

PW Operator Manual PW This operator manual. has information for all. models of series PW plus some options. and accessories.

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

"ELECTRICAL SAFETY IN THE LABORATORY"

AIRSIDE OPERATIONAL SAFETY POLICY SPILL PREVENTION AND RESPONSE MARCH This document is uncontrolled when printed

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

Emergency Response Guide

Powered Industrial Vehicle Policy

PROPANE TORCH WITH TURBO BURNER

Placement on the fireground simply refers to how and where an apparatus is placed at the scene.

9-2 In case of emergency

Table of Contents. Safety symbols... 3 Assembly 6. Operation Maintenance Troubleshooting 11. Storage. 12. Notes. 13

BIG SPRING FIRE DEPARTMENT STANDARD OPERATING PROCEDURES SOG 417: LADDER TRUCK OPERATIONS SOP: 417. Ladder Truck Operations.

SECTION 8 1 DO IT YOURSELF MAINTENANCE. Introduction

BASIC HAZAROUS MATERIAL AWARENESS REVIEW USE OF THE EMERGENCY RESPONSE GUIDE-2008

Transcription:

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures Functional Area: SUPPORT SERVICES/FIRE SERVICES Subject: EMERGENCY OPERATIONS/MOTOR VEHICLE FIRES Revises Previous Authority: Page 1 of WETHERINGTON/HODGE I. POLICY: This standard was promulgated to ensure the safety of members involved in suppressing motor vehicle fires. II. APPLICABILITY: All Dept. of Corrections Certified Firefighters in State and County Fire Departments. III. RELATED DIRECTIVES: IV. DEFINITIONS: V. ATTACHMENTS: VI. PROCEDURE: A. (General Guidelines) 1. The number and variety of motorized vehicles increases each day. It is impossible to completely identify all of the problems that might be encountered while extinguishing such a fire. Nevertheless, some commonalties do exist, and the general guidelines of this standard should be followed when combating a fire in a motorized vehicle.

Page 2 of 2. The Station Chiefs should always remain cautious and assume the worst until he can be certain that conditions are safe. For example, if a burning vehicle is placarded as transporting a hazardous material, assume that the incident is a haz-mat incident until it can be ascertained that no haz mats are burning or have been released. 3. If the fire appears to be the result of an accident, the Station Chief should consider the mechanism of the accident in developing his strategy for managing the incident. 4. The first Priority at the scene of a vehicle fire is rescue. The Station chief must assume that someone is trapped in the burning vehicle until having ascertained that all of the occupants of the vehicle have gotten out. The second priority is the safety of the firefighters, rescue workers, and spectators. If the spectators are present, remove them to a safe distance. Do not place firefighters and rescue workers in harm s way unnecessarily. Remember, do not risk a lot for a little. 6. It is important to control the flow of traffic. The need to minimize the disruption of traffic in heavily congested areas must be balanced by the need to provide for the safety of firefighters and rescue workers. Whenever possible, direct traffic away from the incident. 7. Apparatus placement: a. Position apparatus upwind and uphill from the burning vehicle. This will keep the crew out of the smoke and prevent leaking fuel from running underneath the apparatus. b. Apparatus should not be parked closer than 100 feet from the burning vehicle whenever traffic conditions permit. If the burning vehicle is labeled as transporting a hazardous material, increase this distance based on the

Page 3 of recommendations of the DOT Emergency Action Guide. c. The driver should position the apparatus to block at least one lane of the road to create a barrier between the firefighters and oncoming traffic. Ideally, the angle of the apparatus will allow the driver to view the burning vehicle from the pump operator s position and not expose the driver to oncoming traffic. d. Secure sufficient room for an ambulance, additional apparatus, or a medevac helicopter in case additional resources are needed. 8. Safety precautions: a. Members engaged in firefighting and rescue efforts shall wear full protective clothing and SCBA. Protective clothing shall not be removed until the possibility of re-ignition has been removed. b. The presence of broken glass and other sharp objects mandates that personnel wear gloves and other safety equipment to prevent the possibility of injury even after the fire has been extinguished. c. Stabilize the burning vehicle as soon as possible to prevent movement. This may be accomplished in a variety of ways, such as using wheel chocks, cribbing, a winch, etc. d. If it becomes necessary to open the hood, a hatch, or other opening to make a rescue or extinguish a fire, prop open the hood or hatch to prevent accidental closing due to a failure of a spring, rod, or compressed cylinder. e. De-energize the vehicle as soon as possible by disconnecting the battery. Take care to prevent sparks in the event flammable or combustible vapors or fluids are present.

Page 4 of f. If the operation takes place in darkness, illuminate the scene properly. Operating Firefighters should wear turnouts or other clothing with reflective materials to minimize the risk of being struck by other vehicles, including apparatus. g. Also consider the impact of strobes and other warning lights on visibility. Turn them off when it is safe to do so. h. Firefighters and rescue workers should also be aware of the hazards associated with air bags, energy-absorbing bumpers, downed or over head power lines, hollow drive shafts, high pressure hoses on power steering and air conditioning systems, air-suspension systems, and the danger of exploding tires equipped with split rims, such as the wheels used on larger vehicles and some pickup trucks. i. Establish an adequate water supply. Hose streams should be adequate for the volume of fire. Typically, the minimum size deployed should be a 1 ½-inch. Approach the burning vehicle from upwind whenever possible. j. Never stick your head inside a vehicle while it is still burning and never crawl under a vehicle to extinguish a fire. k. A variety of combustible metals are used for engine blocks, wheels and other components. These may react adversely with water and may require the use of specialized extinguishing agents. 9. Fuel spills: a. A fuel tank may be punctured during an accident or may fail during a fire, thereby causing a spill or runoff. Take precautions to contain the spill and prevent environmental damage. If the fuel has not ignited, take steps to minimize the chance of ignition.

Page of b. A variety of fuels are used in motor vehicles. Of particular concern are LNG and LPG. A leak involving either of these fuels poses special problems, as does the possibility of a fuel tank rupture due to flame impingement. It is critical that these vessels be cooled during a fire. c. Do not remove the fuel tank cap until you are absolutely certain that there is no excess pressure in the tank. d. Do not turn your back on a burning vehicle, and keep charged hose lines available after extinguishments in the event of reignition. e. Prohibit smoking. f. Prevent sparking from tools, saws, etc. g. A fuel leak may be controlled by using lead wool, soap, wood plugs, etc. or by turning off the fuel valves on an LNG or LPG tank. B. (Recommendations) 1. Automobile dealerships are great resources. Personnel should visit them regularly and familiarize themselves with the features of new models. Unfortunately, many of the features that make vehicles safer for the motoring public pose unique hazards for firefighters. 2. Traditionally, the motor vehicle fire has been considered by firefighters to be routine, perhaps even boring. A re-examination of our attitudes and perceptions is in order. Vehicle fires are increasingly dangerous, and firefighters should not become complacent about them.