50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Similar documents
Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Demarcation Fuse Alarm Panel

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Dual-Feed 600A Load Center Frame

100A/60A Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay Alarms Power :: HPGMTXX & GMTXX Installation Guide

Dual-Feed 600A 8-Circuit Breaker/TPC/TFD Load Center With 5 GMTs

Low-Current 20/20 GMT Series Fuse Panels Models & Installation Guide

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

:: :: TFD4 :: TFD6

nrgsmart Power Distribution Remote Monitoring

TPM/GMT Panel Installation Guide

GMT Fuse Panel Installation Guide

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

Installing Power Components

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

PowerWorx DSX Series GMT Fuse Panel User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Application Note. Best Solutions for Managing High-Current Power Distribution

Secondary DC Distribution E R P R P I 2. Technical Reference Guide

NTK599BAE5 and NTK599BGE5 Breaker Interface Panel (BIP) Installation Manual

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

DC Distribution Panel User Guide # S

Connecting to DC Power

Fuse / Circuit Breaker Panels

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

IOE-XXX-XXXX Training Guide

User Manual. Solar Charge Controller 3KW

IMPORTANT SAFEGUARDS

Installing the Switch Chassis

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

ENFORCER TM 6201-IQ ELECTRONIC SIREN

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

DPoE Power System. User Manual

High Frequency SineWave Guardian TM

RU SERIES UPGRADE TempAssure Compatible

Circuit protection for telecom applications

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Electronic Circuit Breaker ESS20-0..

REMOTE POWERING Central Energy System ( HUB )

ANZI Transfer Switch and Generator Wiring Installation Addendum

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Power and Cooling. Chassis Power System

CONTROL FEATURES AVAILABLE OPTIONS

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Sentinel Field Satellite Controller

User Manual Solar Charge Controller 3KW

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

Installation and Operations Manual

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

SAVE THESE INSTRUCTIONS

HMW Filtered Fuse Panel for GMT Fuses

Fuseholders PAGE. Fuseholders.

Raidtec 20-Inch Rack Mount Guide Version 1.0

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

CM52 Network Protector with Arc Flash Reduction Module

INSTALLATION INSTRUCTIONS

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Installing the ONS M6 Shelf

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CALTRAP INSTALLATION AND OPERATIONS MANUAL

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

GROUNDING & BONDING PRODUCTS

Unity Low Voltage Disconnect & Monitor

MIL-24/2600Q MIL-24/3200DQ

Products. Section Contents

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

POWER TRIM 5 E DUAL POWER TRIM CONTROL

ISIS Power Manual and Installation Guide Race Car Replicas- Superlite Coupe

Generator Fire Safety: Generator assemblies should be located outside the building.

E.S.P. Embedded Sensing Probes for Motor Brushes

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

DC to AC Power Inverters

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Transcription:

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA

Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6 1.4.1 Installation Considerations...6 1.4.2 Mounting the Panel...7 1.5 Accessories...12 1.6 Assembly Drawing...13 1.7 Schematic...14 List of Figures Figure 1 - Brackets Oriented for Wall Mounting...3 Figure 2 - Brackets Oriented for Rack Mounting...3 Figure 3-23 Rack Mount,...7 Figure 4-19 Rack Mount,...7 Figure 5-19 Rack Mount Flush...7 Figure 6-23 Rack Mount Flush...7 Figure 7 - Rack Mounting...8 Figure 8 - Wall Mounting...8 Figure 9 - Ground Lug Connection...9 Figure 10 - Input Connections...9 Figure 11 - Status LEDs & Alarm Terminals...10 Figure 12 - Output Connections... 11 Figure 13 - Installing GMT Fuses... 11 ii

1.1 Overview Figure 1 - Brackets Oriented for Wall Mounting Figure 2 - Brackets Oriented for Rack Mounting Telect s 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel is a compact 1RU, EIA panel enabling ±24 and -48 Vdc power protection for a variety of local/remote central office, datacenter, and cell-tower telecommunications equipment. The panel provides total front access to inputs, outputs, alarms, LED indicators, and fuses. Its small form factor less than 2 in. (~ 50 mm) in depth makes it ideal for mounting to either front or rear rack flange. Re-orient mounting brackets to install on a wall. Each of the 50A feeds provides power for up to 5 GMT-protected loads of up to 15A each. The GMT fuse blocks are mounted upside-down so that the GMT indicator flag flips downward when activated, making identification and detection easier, especially on tall racks. Holes for color coded fuse designation pins are located above each fuse position. 1

Other features include power and fuse fail LEDs for each feed plus dry Form-C alarm connections for both power and fuse failures. Visit our website (telect.com) or see Page 10 to order GMT fuses and fuse designation pins. GMT05FA is listed by UL for USA and Canada, and NEBS (Level 3) certified. 1.2 Rack-mounting Considerations 1. Elevated Operating Ambient - If the equipment is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, give consideration to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. 2. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 3. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. 4. Circuit Overloading - Consider the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Use appropriate consideration of equipment nameplate ratings when addressing this concern. 5. Maintain reliable earthing of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips). 1.3 Specifications Inputs: Specifications: Voltage & Range ±20 VDC to -60 VDC @ 20 C ±22 VDC to -58 VDC @ 55 C Max. Input Load Rating Max. Power Dissipation at Full Load 50A 11W per side % of Full Load Power Dissipation less then 1% Max. Input Interruption Device Input Terminals Input Wire Size 60A Dual M5 studs on 5/8-in. centers. Torque KEPS nut (using 5/16-in. or 8-mm socket) to ~20 in.-lb (~2.3 N m). 8 AWG for a 50A feed 2

Outputs: Max. GMT Output Fuse (ea.) Max. GMT Output Load (ea.) Max. Total GMT Output Per Side Output Terminals Specifications: 15A 12A continuous 50A 10 Pairs of 6-32 panhead compression/wire-binding terminals GMT Output Wire Size Range #26 to #14 AWG, depending on output fuse (1/4A to 15A) Alarms: Alarm Relay Contacts Max. Alarm Power Rating Alarm Wire Size Alarm Terminals Amphenol-Type Connector (Unshielded) 64 Pins Specifications: Dry Form-C contacts (1A @ 30 Vdc) @24V: 24 ma (0.58W) @48V: 48 ma (2.30W) Up to 16 AWG # 3 panhead screws with wire-binding plates Environmental: Operating Temperature Range Environmental: Specifications: -10 C (14 F) to 55 C (131 F) Physical (Nominal): Width x Height x Depth Weight (Installed) Weight (Shipping) Material & Color Mounting Options Specifications: 17.25 x 1.75 x 2 in. (438 x 44 x 50 mm). See Page 11 for details. 3.6 lb (1.6 kg) ~4.0 lb (~1.8 kg) Steel (grey powder coat) Wall or EIA Rack (19 in. and 23 in.) Grounding: Chassis GND Terminal Studs (With KEPS Nuts) for Single-Hole Compression Lug Specifications: 1/4-20 stud. Torque KEPS nut (using 7/16-in. socket) to ~20 in.-lb (~2.3 N m). 3

1.4 Installation! ALERT ALERT! Install this product within a restricted access location where access is through the use of a tool, lock and key, or other means of security, and is controlled by the authority responsible for the location. Only qualified personnel may install and maintain this product! ALERT ALERT! Verify that all connections meet requirements specified in local electric codes or operating company guidelines before supplying power. Protect this equipment with a fuse or breaker sufficient to interrupt power levels specified under Inputs on the preceding table of specifications. 1.4.1 Installation Considerations Please read and understand all instructions before starting installation. If you have questions, contact Telect Technical Support at support@telect.com or call 1.509.926.6000. When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Telect Quality at quality@telect.com or call 1.509.926.6000. Telect is not liable for transit damaged. If the product is damaged, please report it to the carrier and contact Telect Quality. 4

1.4.2 Mounting the Panel NOTE: Panel brackets provide flush or extended mounting on an EIA, 19-in. or 23-in. rack. The mounting brackets also allow for flush or extended mounting on a wall. Procedure steps: 1. Install the brackets using the four screws included with brackets, as shown in the following illustrations. 2. Mount the panel using the screws provided, as shown. Figure 3-23 Rack Mount, Extended or Wall-Mounted Figure 4-19 Rack Mount, Extended or Wall-Mounted Figure 6-23 Rack Mount Flush Figure 5-19 Rack Mount Flush 5

For rack mounting, locate an unused EIA rack position, normally at the top of the rack. Mount the panel to the rack using the four, 12-24 thread-cutting screws and washers provided, as shown on the right. Tighten the screws to 35 in.-lb (4.29 N m). For wall mounting, use four appropriate fasteners (and anchors, if needed) along with the #12 washers provided. Figure 8 - Wall Mounting Figure 7 - Rack Mounting It is best to mount the panel on a plywood board that has been securely anchored to the wall. If you mount the panel on a metal strut, in a cabinet, or onto other metal objects, make sure to ground the metal object along with the panel! WARNING WARNING! Failure to properly ground this equipment can create hazardous conditions to installation personnel and to the equipment.! ALERT ALERT! Only use components and crimping tools approved by agencies or certifying bodies recognized in your country or region such as Underwriter s Laboratories (UL), TUV, etc. 6

3. Use a listed (approved) crimping tool to attach a listed (approved), single-hole compression lug for a #10 stud onto 14 AWG ground wire. 4. If desired (highly recommended), lightly coat anti-oxidant on lug, grounding terminal, and surrounding contacting surface. 5. Connect the lug using the M5 KEPS nut provided, as shown on the right. Tighten the KEPS nuts to ~20 in.-lb (~2.3 N m). 6. The installer should verify that a readily accessible 60-amp maximum overcurrent protection device is part of the building installation wiring feeding the fuse panel. 7. Make sure the input power is OFF (open breaker, dummy fuse, or open fuse holder at power distribution unit [PDU]) before connecting this panel s input cables to the PDU.! WARNING Figure 9 - Ground Lug Connection WARNING! Before connecting input power cables, make sure input power to panel is turned off. 8. For input wiring wiring used as inputs to this distribution panel crimp the dual-hole compression lugs onto #10 to #6 AWG conductors (min. 8 AWG for a 50A feed). 9. Insulate the lug barrels with UL94 V-0 rated heat-shrink tubing. Dummy Fuses Figure 10 - Input Connections 7

10. Remove (pull off) the input terminal covers. 11. Clean terminals and lugs with a nonabrasive, nonmetallic cloth, or pad. 12. If desired (highly recommended), lightly coat anti-oxidant on lugs, terminals, and contacting surfaces, and then connect lugs to input terminals on panel. 13. Torque the KEPS nuts to ~20 in.-lb (~2.3 N m). 14. Re-install the input terminal covers. 15. Make sure the GMT fuse positions are either empty or contain dummy fuses (phoney, inoperative all-plastic slugs). 16. Enable the fuse or breaker at the PDU (60A max.) to turn on Feed A to Side A of panel and then check voltage and polarity at input connectors of panel. Also, check that PWR A LED on front of panel turns ON (green). PWR B and both FUSE LEDs must be OFF. 17. With PWR A lit (green for normal operation) but with PWR B LED off test power-fail relay and contacts at PWR FAIL terminals on panel: Expect an open circuit (00Ω) between Terminals C and NC. Expect continuity (0Ω) between Terminals C and NO. 18. Test the fuse alarm relay contacts at FUSE ALM terminals. Expect continuity (0Ω) between Terminals C and NC. Expect an open circuit (00Ω) between Terminals C and NO. 19. Repeat Steps 16 and 17 to power up Side B. PWR A and PWR B must both be green. 20. With PWR A and B lit, test power-fail relay and contacts at PWR FAIL terminals. Expect continuity (0Ω) between Terminals C and NC. Expect an open circuit ( Ω) between Terminals C and NO. 21. Make sure none of the fuse positions contain real, operable fuses. Figure 11 - Status LEDs & Alarm Terminals 8

22. For GMT output wiring, use #24 to #14 AWG copper wire. (Work with one wire at a time.) At this end of the wire, either Crimp a single-hole ring or fork lug, as required by NEC. OR Strip 3/8 in. (10 mm) of insulation for a bare-wire connection. 23. Clean the panel terminals and lug (if applicable) with a nonabrasive, non metallic cleaning pad. 24. If required, lightly coat anti-oxidant on lug/wire and output BATTERY and RETURN terminals, and then connect to the terminals. (NEC specifies only one load at each output terminal.) 25. Tighten the panhead screws to no greater than 8 in.-lb (~1 N m) and then connect the other end of the output wire to load. Figure 12 - Output Connections! ALERT ALERT! GMT fuses have a small inherent electrical resistance resulting in a small inherent power loss. For this reason, the GMT fuse manufacturer recommends that the load for GMT fuses up to and including 7.5A not exceed 80% of the fuse rating and that the load for GMT fuse sizes between 10A and 15A not exceed 70% of the fuse rating. For example, the load for a 15A GMT fuse should not exceed 10.5A (15A x.70 = 10.5A). The TOTAL LOAD FOR ALL FUSE OUTPUTS ON EACH SIDE must NOT exceed 50A. 26. Make sure load devices are off (disabled) and then install the GMT fuses. Remember to install the GMT fuses so that the failure indication flags are at the bottom, as shown in the following illustration. 27. Test power and polarity at input of each equipment load. 28. If possible, replace one of the operable GMT fuses with a blown fuse to verify that the FUSE Alarm LED and FUSE ALM terminals are also as specified above. 29. Re-install the operable GMT fuse before proceeding. 30. If desired, connect the remote external audio/ visual alarm indicator wires (solid or tinned wires, #22 to #18 AWG) to PWR ALARM and FUSE ALM terminals. 31. Enable the equipment loads one at a time to verify proper operation of loads. GMT Fuse Holes are for Colored Fuse Designation Pins Figure 13 - Installing GMT Fuses Dummy Fuse This procedure is complete 9

1.5 Accessories The following lists optional and replacement items for the panel. For compression lugs, please refer to Wire Sizing & Label Convention Chart (Telect Part No. 117995) included with your panel! WARNING WARNING! Use only UL-listed fuses or UL-recognized component secondary protection devices. For dummy fuses, order part number 132748. For GMT safety (splash/splatter) covers, order part number 116915. Telect recommends using only UL-recognized supplementary protectors. Table 1 - GMT Fuses GMT Fuse Part Numbers GMT Fuse.18A Yellow (YEL) 130781 102435-21 ¼A Violet (VIO) 100151 102435-2 ½A Red (RED) 004001 102435-5 ¾A Brown (BRN) 004008 102435-7 1A Gray (GRY) 100991 102435-8 11/3A White (WHT) 004006 102435-9 1½A White/Yellow (WHT/YEL) 004011 102435-10 2A Orange (ORN) 004002 102435-11 2.5A White/Orange (WHT/ORN) 130783 102435-12 3A Blue (BLU) 004012 102435-13 3.5A White/Blue (WHT/BLU) 130782 102435-14 4A White/Brown (WHT/BRN) 004013 102435-15 5A Green (GRN) 004014 102435-16 7½A Black/White (BLK/WHT) 004010 102435-17 10A Red/White (RED/WHT) 004015 102435-18 12A Yellow/Green (YEL/GRN) 102287 102435-19 15A Red/Blue (RED/BLU) 102288 102435-20 Table 2 - Input Lugs for Stranded Copper Conductors (Straight Dual-Hole Lugs for #10 Studs on 5/8 Centers) Manufacturer #6 AWG #8 AWG T & B 256-30695-1183 (T&B Die Code 24) Panduit Burndy LCD6-10A-L (Panduit/T&B Die Code 24) (Burndy Die Code 7) YA6CL2TC10 (Burndy Die Code 7) Colored Designation Pin Part No. 54204 (T&B Die Code 49) LCD8-10A-L (Panduit/T&B Die Code 21) (Burndy Die Code 49) YA8CL2TC10 (Burndy Die Code 49) 10

1.6 Assembly Drawing 0.25 [6.4] 2.88 [73.2] 1.98 [50.4] 1.72 [43.7] 1.25 [31.8] NOTE: All dimensions are in in. [mm]. TOP VIEW 17.25 [438.2] M5 Ground Stud with KEPS Nut & Washer 1 2 3 4 5 1 2 3 4 5 BATT BATT TT BATT www.telect.com FUSE ALM PWR FAIL PWR PWR TN RTN FUSE FUSE RTN RTN GMT TYPE FUSE ONLY 15A MAX A NO C NC NO C NC B GMT TYPE FUSE ONLY 15A MAX 0.32 [8.1] 0.19 [4.8] 0.63 [15.9] 18.31 [465.1] 19.00 [482.6] B INPUT MAX 50A +/-24/48 VDC 10-32 Studs with KEPS Nuts & Washers Lug must be no wider than 0.50 in. (12.8 mm) #6-32 Slot-Head Screws #3 Slot-Head Screws FRONT VIEW 11

1.7 Schematic BATT RTN INPUT A C GND 1 2 3 4 GMT OUTPUT A BATT 5 1 2 INPUT A PWR FUSE ALARM A FUSE ALARM B INPUT B PWR ALARM PCB NO C NC NC C NO PWR FAIL FUSE ALARM 3 4 5 1 2 3 GMT OUTPUT A RTN GMT OUTPUT B RTN 4 5 1 2 3 4 GMT OUTPUT B BATT 5 BATT RTN INPUT B Telect assumes no liability for the application or use of these products. Neither does Telect convey any license under its patent rights or the patent rights of others. This document and the products described herein are subject to change without notice. 12