PRODUCT RANGE PRESENTATION

Similar documents
OPERATING MANUAL LIQUID RING VACUUM PUMPS AND COMPRESSORS Series TRH - TRS - TRM - TRV - SA HYDROSYS - OILSYS

series series liquid ring vacuum pumps liquid ring vacuum pumps

(Rev. 2.0_ ) DISASSEMBLY & ASSEMBLY INSTRUCTIONS SINGLE STAGE CENTRIFUGAL PUMPS TC... MCU-...

PTB GLV. Vertical Centrifugal Pump

SILI PUMP, Your reliable one-stop supplier of marine pumps.

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E:

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS SINGLE STAGE WITH MECHANICAL SEAL TRMB to TRVB to

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Contents. Identification

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

The Modular System SIHI ISOchem

Drainage pumps Series KEP

APIFLO-M series Series

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

High Temperature Chemical Process Inline Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

GARO Liquid Ring Compressors

Bristol: A History & Future.

IDROCHEMICAL CENTRIFUGAL PUMPS FOR CHEMICAL SERVICE ACCORDING TO ISO 2858 STANDARDS

GENERAL DIMENSIONS OF SMF PUMPS. Capacity upto 7,000 m /hr Head upto 45 m. Range :

Jansen Pompentechniek T: +31(0) E:

Vertical multistage centrifugal pumps in ring-section design

High Temperature Air-Cooled Hot Oil Pumps

General. Shaft Seal. Nozzle Orientations. Field of Application. Design. Drive. Bearings. Product Catalogue

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS WITH MECHANICAL SEALS

Submersible Long Shaft Pumps for the Chemical Industry Type NCT/NMT

Side Channel Pumps Self-priming, segmental type with verly low NPSH

BULLETIN January Goulds Model 3700 API th Edition/ISO Process Pumps

G&L Series MPVN. High Pressure Multi-Stage Pumps. Goulds Pumps. ITT Industries

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

AHLSTAR End Suction Single Stage Close Coupled Centrifugal Pump

AURORA Series MODEL 3560 ASME/ANSI B73.1M INDUSTRIAL PROCESS PUMPS

Grupa Powen-Wafapomp SA. Pumps for Power and Heat Supplying Industries catalogue

Drainage pumps Series KEP

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Standard SO according to DIN

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

UTS HE / UTS-B HE. Metallic Magnetic Drive Process Centrifugal Pumps. UTS-B Close Coupled Execution. HE: High Efficiency. Comply to : 2006/42/CE

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN AND DIN EN ISO SEALLESS WITH MAGNET DRIVE

PROJ. NO SECTION HYDRONIC PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

PAS 100HF 250. Diesel - Qmax 280 m³/h (1,230 USgpm) - Hmax 50 m (164 ft) Benefits. PAS MF - Vacuum prime centrifugal pumps

900 Series Split Case Fire Pump Systems

High Temperature Air-Cooled Hot Oil Pumps

Multistage Pumps. Vogel Series P, PVa, MP 300

Bearings. Shaft seal. Materials

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

RS Multi-Stage, Ring Section Pumps

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN ISO 2858 AND DIN EN ISO 15783

Side channel pump PN 40 SRZ. self-priming, according to DIN EN 734. Technical description

Casing. Impeller. Gland. Shaft. Bearing Bracket. Support Foot RANGE APPLICATIONS

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Axially split volute casing pumps. Applications. Bearings. Shaft seal. Operating data

Design Characteristics. Aplicaciones

Goulds API th Edition/ISO nd Edition API OH3 Overhung. Vertical In-Line with Bearing Frame. An ITT Brand

UTS HE / UTS-B HE. Metallic Magnetic Drive Process Centrifugal Pumps. UTS-B Close Coupled Execution. Pompe S.P.A.

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI multi. Modular multistage pumps. Type MSL, MSM. Description. Construction. Applications. Technical Data. Options

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

Features: Applications: Irrigation. Commercial. Construction. Municipal. Mining

EN. 850 Filtrate Pumps. Technical Specification Pages

INDUSTRY APPLICATION. S -pumps are used in: Industry Waste treatment Environment protection Construction industry Civil engineering

ISO 2858 Back Pullout End Suction Centrifugal Pumps

PWA ANSI / ASME B73.1 PROCESS PUMP

ANSI Centrifugal Process Pumps. 911 Series

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

Sump pumps Series ETP

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

PWA-IL B73.2 IN-LINE

WMDA Series WMDA. Seal-less Mag-Drive Pumps. MAG-DRIVE ANSI-B73.1 ISO-2858 or API-685 CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BMPVN MPVN HIGH PRESSURE MULTI-STAGE PUMPS

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

PUMP TYPE Single stage, axially split volute casing pump with double entry radial impeller, for horizontal installation.

50 Hz PX CHANNEL 1. Performance curves. data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s. Tolerances acc.

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

PAS 300MF 390 DATA SHEET

High pressure centrifugal pumps

EAN PUMP SERIES DL200/DL230

High-pressure pumps Series HP45

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

NJK Series ISO Standard End-Suction Centrifugal Pumps

Normpumpen nach DIN EN 733 einschl Standard horizontal pumps to DIN EN 733 NORMA J ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Goulds 3181 High-temperature/Pressure Paper Stock/ Process Pumps

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

Wilo IL Vertical Inline Pumps. Engineering Specification

Transcription:

PRODUCT RANGE PRESENTATION Mexico City, January 2013 1

LIQUID RING VACUUM PUMPS TRS (single stage) TRH (two stages) TRV (single stage vari-ported design) TRM (single stage vari-ported design monoblock) TRMX(single stage vari-ported design monoblock new design ) TRVX (single stage vari-ported new design) TRVK-TRSK (single stage king size) 2

TRS (single stage) 3

TRS (single stage) Vacuum range : up to 24/25.5 Hg(V) 200/150 mbar Suction pressure range : 0-24/25.5 Hg(V) 150/200-1013mbar(a) Capacity @ 50Hz : up to 1800 ACFM or 3100 m3/h Capacity @ 60Hz : up to 2100 ACFM or 3500 m3/h Max compression rate : ~6 times 29.92/25 Hg(A) or 1013/150 mbar(a) Number of sizes available : 15 + 7 (TRSC 32; 40; 50 alternative to TRSE 32; 40; 50) C construction : port plates separate from pump casings (other constructions) Construction : all sizes bilateral support Lantern construction : up to 40HP (50Hz); up to 50HP (60Hz) to fit flanged e-motors 4

TRH (double stage) 5

TRH (double stage) Vacuum range : 23/24 up to 28.94 Hg(V) max 33 mbar Suction pressure range : 33 250 mbar(a) Capacity @ 50Hz : up to 1900 ACFM or 3200 m3/h Capacity @ 60Hz : up to 2200 ACFM or 3700 m3/h Max compression rate : ~30 ~ 29.92/1.02 Hg(A) or 1013/33 mbar(a) Number of sizes available : 18 + 6 (TRHC 32; 40 alternative to TRHC 32; 40) C construction : port plates separate from pump casings (other constructions) Construction : all sizes bilateral support (but TRHE 32-4) Lantern construction : up to 40HP (50Hz); up to 50HP (60Hz) to fit flanged e-motors 6

TRV (single stage vari-ported design) 7

TRV (single stage vari-ported design) Vacuum range : up to 28.94 Hg(V) max 33 mbar Suction pressure range : 30 1013 mbar(a) Capacity @ 50Hz : up to 250 ACFM or 420 m3/h Capacity @ 60Hz : up to 300 ACFM or 500 m3/h Max compression rate : ~33 ~ 29.92/1.02 Hg(A) or 1013/33 mbar(a) Number of sizes available : 5 + 1 (TRVB 50-300 for 50Hz markets) + 2 (TRVB 32-25 and TRVA 50-220 for 60Hz markets) Construction : overhung construction (up to size TRVB 40-200) to fit only flanged e-motors; bilateral support (TRVA 50 - TRVA 65) Lantern construction : available for all TRVA 8

TRM (single stage vari-ported design monoblock) NEW 9

TRM (single stage vari-ported design monoblock) Vacuum range : up to 28.94 Hg(V) max 33 mbar Suction pressure range : 33 1013 mbar(a) Capacity @ 50Hz : up to 165 ACFM or 280 m3/h Capacity @ 60Hz : up to 140 ACFM or 240 m3/h Max compression rate : ~ 30 ~29.92/1.02 Hg(A) or 1013/33 mbar(a) Number of sizes available : 6 + 1 (TRMB 50-300 for 50Hz markets) Construction : overhung design e-motor shaft mounted 10

TRVX (single stage vari-ported new design) 11

TRVX (single stage vari-ported new design) Vacuum range : up to 28.94 Hg(V) - max 33 mbar Suction pressure range : 33 1013 mbar(a) Capacity @ 50Hz : up to 165 ACFM or 280 m3/h Capacity @ 60Hz : up to 140 ACFM or 240 m3/h Max compression rate : ~30 ~29.92/1.02 Hg(A) or 1013/33 mbar(a) Number of sizes available : 4 (TRVX 1007 1005 1003 TRVX 1257), more size under development X construction : port plates separate from pump casings in stainless steel Construction : bilateral support Lantern construction : up to 40HP (50Hz); up to 50HP (60Hz) to fit flanged e-motors 12

TRVK-TRSK (single stage King Size) 13

TRVK-TRSK (single stage King Size) TRVK vacuum range : up to 28.7 Hg(V) 40 mbar TRSK vacuum range : up 24 Hg(V) 200 mbar TRVK suction pressure range : 40 1013 mbar(a) TRSK suction pressure range : 200 1013 mbar(a) Capacity : up to 17,500 ACFM or 30,000 m3/h TRVK max compression rate : ~24 ~29.92/1.22 Hg(A) or 1013/40 mbar(a) TRSK max compression rate : ~5 ~29.92/6 Hg(A) or 1013/200 mbar(a) Number of sizes available : 8 x TRVK + 12 x TRSK Shaft construction : dry execution with sleeves Construction : bilateral support 14

TRADITIONAL PUMPS NOMENCLATURE T = Travaini R = liquid ring TRHC 80-750/C-M/GH S = single stage; H = two stages; V = single stage vari-ported design; M = single stage monoblock design A; B; C; E = Design number 80 = flanges diameter in mm 750 = nominal capacity in m3/h at 50Hz C = single mech. seal; C2 = double mech. seal; B = packing gland M = closed coupled construction design lantern F; GH; RX; RZ; RA; A3; = materials of construction 15

NEW PUMPS NOMENCLATURE TRVX 1007/C-M/F T = Travaini R = liquid ring V = single stage vari-ported design X = stainless steel port plates 100 = flanges diameter in mm 7 = pump size C = single mech. seal; C2 = double mech. seal; B = packing gland M = closed coupled construction design lantern F; RX; RZ; RA; A3; = materials of construction 16

SA0 (Double Acting, Liquid Ring Compressors) 17

SA0 (Double Acting, Liquid Ring Compressors) Capacities up to 106 SCFM - 180 m 3 /h Pressure up to 160 PSIG 11 bar Pressure range : 30-160 PSIG (2-11 bar) Number of models/sizes available : 3 SA0E3U (40 SCFM max / max 160 PSIG) SA0G2D (65 SCFM max / max 120 PSIG) SA0G2G (105 SCFM max / max 120 PSIG) 18

SA0 COMPRESSORS NOMENCLATURE SA 0 G 2 G / C - GH SA = Double acting liquid ring compressor 0 = Design number G; E = Flange Size: E = 32 mm. 1.26 ; G = 50 mm. 1.97 ; 2; 3 = Number of impellers D ; G ; U = 1 st stage impeller dimension: D = 60 mm. 2.36 ; G = 90 mm. 3.54 ; U = 46 mm. 1.81 C ; C2; B = Shaft sealing type: C = mech. Seal ; C2 = double mech. Seal ; B = Packing seal GH ; RA ; A3 = Materials of construction 19

MATERIAL CODES VDMA N Description F GH RX RZ RA A3 106 Suc. casing 107 Dis. casing 316 137 Port plate Cast iron 316 316 110 Imp. housing 316 210 Shaft AISI 420 AISI 316 147 Manifold Carbon steel 316 357 Bearing hous. Cast iron 230 Impeller Ductile iron Bronze AISI 304 AISI 316 AISI 316 AISI 316 20

VACUUM PACKAGES HYDROSYS HYDROPACK OILSYS HYDROTWIN OILTWIN Liquid ring vacuum systems with service liquid (water, oil or others ) recirculation 21

HYDROSYS 22

HYDROSYS Vacuum range : up to 28.94 Hg(V) Suction pressure range : 33 1013 mbar(a) Capacity @ 50Hz : up to 1900 ACFM or 3200 m3/h Capacity @ 60Hz : up to 2200 ACFM or 3700 m3/h Service liquid : water (over 90% of cases) Recirculation : total or partial Heat exchangers : tube (liquid/liquid cooler), plates (liquid/liquid cooler), radiator (air/liquid cooler) Sizes available : 7 (from Hydrosys 2 to Hydrosys 8) Pump lantern construction : up to 40HP (50Hz); up to 50HP (60Hz) to fit flanged e-motors Accessories : available according to working conditions and on customer specification 23

HYDROPACK 24

HYDROPACK Vacuum range : up to 28.94 Hg(V) Suction pressure range : 33 1013 mbar(a) Capacity @ 50Hz : up to 500 ACFM or 950 m3/h Capacity @ 60Hz : up to 600 ACFM or 1000 m3/h Service liquid : oil Recirculation : total and partial Heat exchangers : radiator air/liquid cooler), Sizes avaiiable : (from Hydropack 2; 4; 5; 6) Pump lantern construction only : up to 40HP (50Hz) to fit flanged e-motors Accessories : standard included, others limited by space 25

OILSYS 26

OILSYS Vacuum range : up to 29.18-29.33 Hg(V) Suction pressure range : 20 1013 mbar(a) Capacity @ 50Hz : up to 950 ACFM or 1600 m3/h Capacity @ 60Hz : up to 1000 ACFM or 1700 m3/h Service liquid : oil Recirculation : total Heat exchanger : radiator air/liquid cooler), Sizes avaiiable : 6 (from Oilsys 2 to Oilsys 7) Pump lantern construction : available on request, up to 40HP (50Hz) Accessories : standard included, available according to working conditions and on customer specification 27

OILPACK 28

HYDROTWIN - OILTWIN 29

HYDROTWIN - OILTWIN Vacuum range : up to Hydro 29.77 - Oil 29,86 Hg(V) Suction pressure range : Hydro 5-1013 Oil 2-1013 mbar(a) Capacity @ 50Hz : up to 1500 ACFM or 2500 m3/h Capacity @ 60Hz : up to 2100 ACFM or 3500 m3/h Service liquid : Hydrotwin water OilTwin oil Recirculation : Hydrotwin total or partial Oiltwin total Heat exchangers : Hydrotwin Shell & tubes (liquid/liquid cooler), plates (liquid/liquid cooler) Oiltwin radiator (air/oil cooler) Sizes available : 8 and more both Hydrotwin and Oiltwin Pump lantern construction : up to 40HP (50Hz); up to 50HP (60Hz) to fit flanged e-motors Accessories : available according to working conditions and on customer specification 30

CENTRIFUGAL PUMP MONOSTAGE TCH (close impeller design) TCT (vortex impeller design) TCA (fully open impeller between wear plates design) TCD (close impeller design, oil thermal fluids version construction) MCU-CH (close impeller design) TCK (close impeller magnetic driven design) TCHM-TCTM (derivate from TCH and TCT monoblock design with grease lubricated bearing) 31

TCH 32

TCH Capacity : up to 500 m3/h 2600 USGPM Total head : up to 16 bar 475 feet Number of size available : 33 Pumped medium type : clear liquids Pumped medium temperature : from -40C (-40 F) till 280 C (536 F) in function of materials of construction and pumped liquid Standards: ISO 2858 (DIN 24256) performance and dimensions; optional ISO 5199 construction Construction variant : U2 jacketed heated casing, T cooling/heating chamber Sealing arrangements : several including the most diffused packing gland, single & double mech., single & double cartridge, etc Support : overhung with 3 oil lubricated ball bearings Lantern construction : available on all pumps to fit flanged e-motors 33

ISO 2858-5199 These two norms are ruling the way to design and build the pumps for chemical application in Europe and all the NON-ANSI world. ISO 2858 points: Designation. Static pressure test parameters. Sizes (Inlet/Outlet/Impeller diameters),. Nominal working conditions (RPM-Flow-Head). pump main overall dimensions. ISO 5199 (108 pages!) main points: Nominal power of motor considering pump absorbed power. One block impeller (closed, semi-open or open type). Shaft dimensions, eccentricity and deflection. Rotating bearings (ball/needle) life 17,500 hours minimum. Hydrostatic test parameters. Forces acting on flanges (resistance of flanges). Vibrations limit. Allowable corrosion thickness on castings (minimum 3 mm. 0.12 ). 34

TCT 35

TCT Capacity : up to 250 m3/h 1200 USGPM Total head : up to 7 bar 320 feet Number of size available : 21 Pumped medium type : liquids with suspended solids or filaments (in limited percentage) and muddy as viscous liquids Pumped medium temperature : from -40C (-40 F) till 280 C (536 F) in function of materials of construction and pumped liquid Standards: ISO 2858 (DIN 24256) performance and dimensions (except for length); optional ISO 5199 construction Sealing arrangements : several including the most diffused packing gland, single & double mech., single & double cartridge, etc Support : overhung with 2 oil lubricated roll bearings Lantern construction : available on all pumps to fit flanged e-motors 36

TCA 37

TCA Capacity : up to 100 m3/h 280 USGPM Total head : up to 10 bar 300 feet Number of size available : Pumped medium type : liquids containing abrasive compounds (such as vegetable oils with bleaching earths) Pumped medium temperature : from -40C (-40 F) till 280 C (536 F) in function of materials of construction and pumped liquid Standards: ISO 2858 (DIN 24256) performance and dimensions (except for length); optional ISO 5199 construction Sealing arrangements : several including the most diffused packing gland, single & double mech., single & double cartridge, etc Support : overhung with 2 oil lubricated roll bearings Lantern construction : available on all pumps to fit flanged e-motors 38

TCD 39

TCD Capacity : up to350 m3/h 900 USGPM Total head : up to 10 bar 300 feet Number of size available : Pumped medium type : clear liquids Pumped medium temperature : from -40C (-40 F) till 320 C (608 F) in function of materials of construction and pumped liquid Construction : dimensions and characteristic in accordance ISO 2858/DIN 24256 Construction variant : U0 jacketed heated casing Sealing arrangement : single mech. Support : overhung with 2 oil lubricated roll bearings Lantern construction : not applicable 40

MCU-CH 41

MCU-CH Capacity : up to 1200 m3/h 3800 USGPM Total head : up to 6 bar 280 feet Number of size available : 7 Pumped medium type : clear liquids Pumped medium temperature : from -40C (-40 F) till 280 C (536 F) in function of materials of construction and pumped liquid Standards: ISO 2858 (DIN 24256) performance and dimensions* Construction variant : U2 jacketed heated casing, T cooling/heating chamber Sealing arrangements : several including the most diffused packing gland, single & double mech., single & double cartridge, etc Support : overhung with 2 oil lubricated roll bearings Lantern construction : not available * = some pumps are not in compliance with ISO 2858, because the norm does not cover those sizes 42

TCK 43

TCK Derivate from the TCH hydraulic and construction Capacity : up to 280 m3/h 900 USGPM Total head : up to 14 bar 500 feet Number of size available : 21 Pumped medium type : clear liquids Pumped medium temperature : from -40C (-40 F) till 250 C (480 F) in function of materials of construction and pumped liquid Standards: ISO 2858 (DIN 24256) performance and dimensions Construction variant : U2 jacketed heated casing magnet Sealing arrangements : magnetic coupling Support : overhung with 2 oil lubricated roll bearings Lantern construction : available on all pumps to fit flanged e- motors 44

TCHM - TCTM 45

TCHM - TCTM Derivates from TCH and TCT hydraulic construction TCHM Capacity : up to 500 m3/h 2200 USGPM TCHM Total head : up to 10 bar 320 feet TCHM Number of size available : 28 TCHM Pumped medium type : clear liquids TCTM Capacity : up to 200 m3/h 950 USGPM TCTM Total head : up to 7 bar 220 feet TCTM Number of size available : 18 TCTM Pumped medium type : liquids with suspended solids or filaments (in limited percentage) and muddy as viscous liquids Pumped medium temperature : from -30C (-22 F) till 140 C (285 F) in function of materials of construction and pumped liquid Sealing arrangements : single mech. seal Support : overhung with 1 grease lubricated roll bearing Lantern construction : only available on all pumps to fit flanged e- motors 46

PUMPS NOMENCLATURE TCH 32-160/1X-C/A3-M/U2-Z T = Travaini C = centrifugal single stage H = close impeller; T = vortex impeller; A = fully open impeller; D = thermal oil design 32 = discharge flange diameter 160 = nominal diameter of impeller 1X = constructive project C = type of shaft seal GS; RA; A3; HC; DU = materials of construction M = closed coupled construction design lantern U2-Z = special execution 47

TMA multistage centrifugal pumps Capacity : up to 45 m3/h 240 USGPM Total head : up to 40 bar 1300 feet Number of size available : 50 (50Hz market); 27 (60Hz) Pumped medium type : clear liquids Pumped medium temperature : from -10C (14 F) till 160 C (320 F) in function of materials of construction and pumped liquid Models at 50Hz : TMA 31-TMA 32-TMA 40 up to 15 stages and TMA 50 up to 12 stages Models at 60Hz : TMA 31-TMA 32-TMA 40 up to 9 stages and TMA 50 up to 8 stages Sealing arrangements : several including the most diffused packing gland, single & double mech. Support : bilateral with grease lubricated roll bearings Lantern construction : available on all TMA 31 and 32 to fit flanged e- motors TMA 31 and 32 available also in vertical execution 48

PUMPS NOMENCLATURE TMA 32-4/1-C/A3-M/T-V-Z T = Travaini M = centrifugal multi stages A = Max pressure 40 bar 32 = pump size 4 = number stages 1 = constructive project C = type of shaft seal F; FZ; RA; A3 = materials of construction M = closed coupled construction design lantern T-V-Z = special execution 49

TBH-TBA multistage, side channel, self priming pumps 50

TBH-TBA multistage, side channel, self priming pumps Capacity : up to 70 m3/h 350 USGPM Total head : up to 40 bar 1100 feet Number of size available : 107 (50Hz market); 81 (60Hz) Pumped medium type : clear liquids Pumped medium temperature : from -10C (14 F) till 160 C (320 F) in function of materials of construction and pumped liquid Models at 50Hz : TBH 200; 290; 300; 310; 400; 500; 650 up to 8 stages and TBH 1000 up to 3 stages Models at 60Hz : TBH 200; 290; 300; 310; 400; 500; 650 up to 6 stages and TBH 1000 up to 3 stages 51

TBH-TBA multistage, side channel, self priming pumps Sealing arrangements : several including the most diffused packing gland, single & double mech. TBH Support : bilateral with 2 grease lubricated roll bearings or with element bushing + 1 grease lubricated roll bearing TBH available also in vertical execution (except TBH 1000) TBA Support : bilateral with element bushing + 1 grease lubricated roll bearing Lantern construction : available on all TBH-TBA to fit flanged e-motors (except TBH 1000) 52

PUMPS NOMENCLATURE TBH 403/1-C/A3-M/T-V-Z T = Travaini B = multistage side channel self priming H; A = type of construction 40 = pump size 4 = number stages 1 = constructive project C; R; RR; C2 = type of shaft seal GH; RA; A3; B2; GP = materials of construction M = closed coupled construction design lantern T-V-Z = special execution 53

THANKS FOR THE ATTENTION 54