G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Similar documents
3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Ordering Information. Text Surface-Mounting Signal Relay G6K

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch (Hinged Type)

Ordering Information. Text PCB Power Relay G5LE

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Model Number Structure

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Subminiature Basic Switch

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

Safety-door Switch. Ordering Information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

2c 15A, 4c 10A polarized power relays

General Purpose Relay

DATA SHEET. Compact and lightweight, High breakdown voltage, Surface mounting type

Wire. Socket (with polarizing guide) Wire can be connected without stripping cable insulation. IDC contacts. Rise in temperature ( C)

1 Form A 5A small size power relay for interface

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Model Number Structure

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Model Number Structure

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

General Purpose Relay

Mechanical Key Switch

B3F. Miniature, Space-saving Switch

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

2NC (slow-action) Direct. Model. opening

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Small Limit Switch D4V

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

COMPACT FLAT SIZE FOR AUTOMOTIVE

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Power Contactor with Mirror Contacts

COMPACT FLAT SIZE FOR AUTOMOTIVE

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

General Purpose Relay

TV-5, TV-8 rated 10mm flat power relays Silent type is available

MIDDLE LOAD RELAY FOR SMART J/B

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

SG-B1 SERIES / SG-A1 SERIES

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Surface mounting, flush mounting, and DIN track mounting

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

Switching Power Supply

HL (AZH) Limit Switches

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Hinged Safety Door Switch

RU Series Universal Relays

Manual Reset Limit Switch

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Model Number Structure

Type Terminal Coil Contact form Model

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Transcription:

with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)). Light weight of. g contributes to higher speed mounting. Consumes approximately % the power of a conventional OMRON model and operates at a current that is as low as mw. Surface mounting terminal models incorporate a unique terminal structure with high infrared irradiation efficiency which allows the terminal temperature to rise easily when mounting the IRS, thus ensuring excellent soldering. Ensures a dielectric strength of, VAC and conforms to FCC Part 8 (i.e., withstanding an impulse withstand voltage of, V for μs). -Y models offer an impulse withstand voltage of 2, V for 2 μs (conforms to Telcordia specifications) by optimizing the distance between coil and contacts. Standard model conforms to UL/CSA standards, certified by BSI (EN9). RoHS Compliant Model Number Legend @-@@-@. Relay function None : Single-side stable model U : Single-winding latching model 3. Terminal Shape F : Outside-L surface mounting terminals : Inside-L surface mounting terminals P : PCB terminals 4. Approved standards None : UL, CSA, BSI (EN9) Y : UL, CSA, BSI (EN9) Conforms to Telcordia specifications: 2, V for 2 μs Ordering Information Surface Mounting Terminal Standard Models Relay Function Single-side stable Single-winding latching Enclosure rating Fully sealed Fully sealed Contact form DPDT (2c) DPDT (2c) Model -2F Highly insulated -2F-Y -2 Highly insulated -2-Y Highly insulated U-2F-Y Highly insulated U-2-Y 2. Number of contact poles/contact form 2: 2-pole/DPDT (2c) Rated coil voltage 2 VDC 2 VDC 2 VDC 2 VDC 2 VDC 2 VDC Minimum packing unit pcs/tube (9 pcs/reel) Application Examples Telecommunication equipment Office automation machines Medical equipment Test and measurement equipment Building automation equipment PCB Terminal Standard Models Relay Enclosure Contact Rated coil Minimum Model Function rating form voltage packing unit -2P 2 VDC Single-side Fully DPDT stable sealed (2c) Highly insulated pcs/tube -2P-Y 2 VDC Highly Single-winding Fully DPDT insulated latching sealed (2c) U-2P-Y 2 VDC Note. When ordering, add the rated coil voltage to the model number. Example: -2F Rated coil voltage Note 2. When ordering tape packing, add -TR" to the model number. Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.

Ratings Coil: Single-side Stable Models Rated voltage Item Rated current (ma) Coil resistance (Ω) 33. 9 2 94 2. 23 2 VDC 9.,3 4.,22 Must operate voltage (V) Must release voltage (V) % of rated voltage Max. voltage (V) 8% % % Power consumption (mw) Approx. Note. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±%. Note 2. The operating characteristics are measured at a coil temperature of 23 C. Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Contacts Item Load Resistive load Contact type Bifurcated crossbar Contact material Ag (Au-Alloy contact) Rated load.3 A at 2 VAC, A at Rated carry current A Max. switching voltage 2 VAC, VDC Max. switching current A Coil: Single-winding Latching Models (U-2F-Y, U-2-Y, U-2P-Y) Rated voltage Item Rated current (ma) Coil resistance (Ω) 33. 9 2 94 2. 23 2 VDC 9.,3 Must operate voltage (V) Must release voltage (V) % of rated voltage Max. voltage (V) % % % Power consumption (mw) Approx. 4.,22 Note. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±%. Note 2. The operating characteristics are measured at a coil temperature of 23 C. Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Characteristics Relay Function Single-side stable models Single-winding latching models Item -2F, -2, -2P -2F-Y, -2-Y, -2P-Y U-2F-Y, U-2-Y, U-2P-Y Contact resistance * mω Operating (set) time 3 ms Release (reset) time 3 ms Minimum set/reset signal width ms Insulation resistance *2, MΩ (at ) Between coil and contacts, VAC, / Hz for min Dielectric strength Impulse withstand voltage Vibration resistance Shock resistance Durability Between contacts of different polarity, VAC, / Hz for min Between contacts of the same polarity VAC, / Hz for min Between coil and contacts, V ( μs) 2, V (2 μs),, V ( μs) Between contacts of different polarity, V ( μs) Between contacts of the same polarity Destruction -- Hz, 2. mm single amplitude ( mm double amplitude) and to Hz, 3 m/s 2 Malfunction -- Hz,. mm single amplitude (3.3 mm double amplitude) and to Hz, 2 m/s 2 Destruction, m/s 2 Malfunction m/s 2 Mechanical,, operations (at 3, operations/hour) Electrical, operations (with a rated load at,8 operations/hour) μa at mvdc -4 to C (with no icing or condensation) Failure rate (P level) *3 Ambient operating temperature Ambient operating humidity % to 8% Weight Approx.. g Note: The above values are initial values. *. The contact resistance was measured with ma at VDC with a voltage-drop method. *2. The insulation resistance was measured with a megohmmeter applied to the same parts as those used for checking the dielectric strength. *3. This value was measured at a switching frequency of 2 operations/min and the criterion of contact resistance is Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. 2

Engineering Data Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Coil Voltage Switching current (A) 3...3 DC resistive load AC resistive load Durability (x 4 operations), 3 3 3 2 VAC resistive load Ambient temperature: 23 C Switching frequency:,8 operations/hour resistive load Ambient temperature: 23 C Switching frequency:,8 operations/hour Maximum coil voltage (%) 2 2. 3 3, Switching voltage (V) Ambient Temperature vs. Switching Current.2.4..8.2 Switching current (A) Ambient Temperature vs. Must Operate or Must Release Voltage 4 2 2 4 8 Ambient temperature ( C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient Temperature vs. Must Set or Must Reset Voltage U-2 (F/P)-Y Switching current (A).2.8..4 On the basis of rated voltage (%) 9 8 4 3 X X On the basis of rated voltage (%) 9 8 Max. estimated value X.2 4 2 2 4 8 Shock Malfunction X,, Z' Shock directions X X' Y Z Z' Y' 2 4 8, Y' Y, Ambient temperature ( C) Energized 8 Deenergized 4 2 Z,, X' Unit: m/s 2 Number of Relays: pcs Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. *, *2 Contact Reliability Test Contact resistance (mω), Number of Relays: pcs Test conditions: μa resistive load at m VDC with an operation rate of % 3 Switching frequency:,2 operations/h 3 NO contact NC contact...,,, Operating frequency (x 3 operations) 2 4 2 2 4 8 Ambient temperature ( C) Electrical Durability (with Must Operate and Must Release Voltage) * On the basis of rated voltage (%) 8 4 2 Number of Relays: pcs Test conditions: A resistive load at with an operation rate of % Switching frequency:,8 operations/h... Operating frequency (x 3 operations) Mutual Magnetic Interference Sample De-energized Sample Energized Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Electrical Durability (Contact Resistance) * Mutual Magnetic Interference *. The test was conducted at an ambient temperature of 23 C. *2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. Initial stage Test +3 +2 + 2 Average value 3 Initial stage Test +3 +2 + 2 Average value 3 Contact resistance (mω) 4, 3 4 2 2 4 8 3 3 Number of Relays: pcs Test conditions: A resistive load at with an operation rate of % Switching frequency:,8 operations/h Contact resistance Ambient temperature ( C) NO contact NC contact... Operating frequency (x 3 operations) Sample Sample De-energized Energized Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Initial stage Test +3 +2 + 2 Average value 3 Initial stage Test +3 +2 + 2 Average value 3 3

External Magnetic Interference Change rate on the basis of initial value (%) +3 +2 + 2 (Average value) S N S N 3 Number of Relays: pcs,2 8 4 4 8,2 External magnetic field (A/m) Change rate on the basis of initial value (%) +3 +2 + 2 S N 3 Number of Relays: pcs,2 8 4 4 8,2 External magnetic field (A/m) S (Average value) N Change rate on the basis of initial value (%) +3 +2 + 2 S N (Average value) 3 Number of Relays: pcs,2 8 4 4 8,2 External magnetic field (A/m) S N High-frequency Characteristics (Isolation) *, *2 High-frequency Characteristics (Insertion Loss) ) *, *2 High-frequency Characteristics (Return Loss) *, *2-2 (F/P),-2 (F/P)-Y Isolation (db) 2 3 Number of Relays: pcs (Average value (initial)) Insertion loss (db). (Average value (initial)) Return loss (db) 2 Sample: -2F-Y Number of Relays: pcs (Average value (initial)).4.3.3 V.SWR 4.2 3 4 Return loss.2.2 8.3.4.. 9 Frequency (MHz) Number of Relays: pcs. Frequency (MHz) V.SWR. 8 Frequency (MHz) Must Operate and Must Release Time Distribution * Must Operate and Must Release Bounce Time Distribution * -2 (F/P), -2 (F/P)-Y Vibration Resistance Number of contacts 4 2 Number of Relays: pcs Must operate voltage Must release voltage Number of contacts 4 2 Must operate bounce time Must release bounce time Change rate on the basis of rated value (%)...... 2 2. 3 Time (ms) Number of Relays: pcs.. 2 2. 3 *. The tests were conducted at an ambient temperature of 23 C. *2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics including endurance in the actual machine before use. Time (ms). Initial After test 4

Dimensions (Unit: mm) Single-side Stable -2F ±.2.±.2 Mounting Dimensions Tolerance: ±. mm 2.8.2±.2..8.±..8.3.9 () ().8.8 2 (.9) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm 8-2 ±.2.8 ±.2.±.2 Mounting Dimensions Tolerance: ±. mm 2.8 8-2P.±. 4.9..8.9 () ().8.8 2 (.9) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm ±.2.±.2. PCB Mounting Holes (Bottom VIEW) Tolerance: ±. mm Eight,.8-dia. holes (Bottom VIEW) 3...4±..9 () ().8 2 R.2.8. (.9) 2 Note: Each value has a tolerance of ±.3 mm. (.).8 8-2F-Y.2±.2..±..2 ±.2.±.2.8.3 Mounting Dimensions Tolerance: ±. mm.8 (.2) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.8 8-2-Y ±.2.8 ±.2.±.2 Mounting Dimensions Tolerance: ±. mm 8.±..2 4.9..8 (.2) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.8. -2P-Y. 3..4±..2 ±.2 R.2.±.2.8. (.2) Note: Each value has a tolerance of ±.3 mm. PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±. mm Eight,.8-dia. holes (.).8 (BOTTOM VIEW) 8

Single-winding Latching U-2F-Y.2±.2..±..2 ±.2.±.2.8.3 Mounting Dimensions Tolerance: ±. mm.8 (.2) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.8 8 S R U-2-Y ±.2.8 ±.2.±.2 Mounting Dimensions Tolerance: ±. mm 8 U-2P-Y.±..2. 3..4±..2 ±.2 R.2 4.9..8 (.2) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.±.2.8. (.2) Note: Each value has a tolerance of ±.3 mm..8 (.). PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±. mm Eight,.8-dia. holes.8 S R (BOTTOM VIEW) S R 8

Tube Packing and Tape Packing () Tube Packing Relays in tube packing are arranged so that the orientation mark of each Relay in on the left side. Fifty Relays are packed on one tube. Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB. Stopper (gray) Orientation of Relays Stopper (green) 2. Reel Dimensions 2±..±. 2±. 2.±. 3±.2 8 33 R Tube length: 2 mm (stopper not included) No. of Relays per tube: pcs (2) Tape Packing (Surface Mounting Terminal Models) When ordering Relays in tape packing, add the prefix -TR to the model number, otherwise the Relays in tube packing will be provided. Relays per Reel: 9 pcs Minimum packing unit: 2 reels (,8 pcs). Direction of Relay Insertion Top tape (cover tape) Pulling direction 3. Carrier Tape Dimensions -2F, -2F-Y, U-2F-Y. +. ±..3.±. 8. 2±. -2, -2-Y, U-2-Y. +. 4±. 2±. 4±. 2±..±..±..4±..±..4±..8±. R.3 Pulling direction ±...±..±. Carrier tape Embossed tape.9 2±. 3 Recommended Soldering Method IRS Method (for Surface-mounting Terminal Relays) () IRS Method (Mounting Solder: Lead) Temperature ( C) 22 to 24 8 to 2 Soldering The thickness of cream solder to be applied should be within a range between and 2 μm on OMRON s recommended PCB pattern. In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side. Correct Soldering Incorrect Soldering Relay Preheating Heel fillet is formed Terminal Land PCB 9 to 2 2 to 3 Time (s) (The temperature profile indicates the temperature on the circuit board.) (2) IRS Method (Mounting Solder: Lead-free) Solder Insufficient amount of solder Visually check that the Relay is properly soldered. Excessive amount of solder Temperature ( C) 2 23 Uppwe surface of case (peak): 2 C Soldering 8 Preheating Relay terminal section 2 3 Time (s) (The temperature profile indicates the temperature on the PCB.)

Approved Standards UL recognized: UL9 (File No. E4) CSA certified: C22.2 No. 9 (File No. LR3928) Contact form DPDT (2c) Coil rating -2(F/P): 3 to (U)-2(F/P)-Y: 3 to Number of Contact rating test operations A, at 4 C. A, VDC at 4 C,.3 A, 2 VAC at 4 C BSI (EN9) (File No.94) Contact form Isolation category Voltage DPDT (2c) Basic Insulation 2 VAC Precautions Please refer to PCB Relays Common Precautions for correct use. Correct Use Long-term Continuously ON Contacts Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. Relay Handling Use the Relay as soon as possible after opening the moistureproof package. If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and sealed the package with adhesive tape. When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 4 C. Do not put the Relay in a cold cleaning bath immediately after soldering. Claw Securing Force During Automatic Mounting During automatic insertion of Relays, make sure to set the securing force of each claw to the following so that the Relays characteristics will be maintained. A C B Direction A:.9 N Direction B: 4.9 N Direction C:.9 N Environmental Conditions During Operation, Storage, and Transportation Protect the Relay from direct sunlight and keep the Relay under normal temperature, humidity, and pressure. Latching Relay Mounting Make sure that the vibration or shock that is generated from other devices, such as relays in operation, on the same panel and imposed on the Latching Relay does not exceed the rated value, otherwise the Latching Relay that has been set may be reset or vice versa. The Latching Relay is reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relay may be set accidentally. Be sure to apply a reset signal before use. Maximum Allowable Voltage The maximum allowable voltage of the coil can be obtained from the coil temperature increase and the heat-resisting temperature of coil insulating sheath material. (Exceeding the heat-resisting temperature may result in burning or short-circuiting.) The maximum allowable voltage also involves important restrictions which include the following: Must not cause thermal changes in or deterioration of the insulating material. Must not cause damage to other control devices. Must not cause any harmful effect on people. Must not cause fire. Therefore, be sure to use the maximum allowable voltage beyond the value specified in the catalog. As a rule, the rated voltage must be applied to the coil. A voltage exceeding the rated value, however, can be applied to the coil provided that the voltage is less than the maximum allowable voltage. It must be noted that continuous voltage application to the coil will cause a coil temperature increase thus affecting characteristics such as electrical life and resulting in the deterioration of coil insulation. Coating The Relay mounted on the PCB may be coated or washed but do not apply silicone coating or detergent containing silicone, otherwise the silicone coating or detergent may remain on the surface of the Relay. PCB Mounting If two or more Relays are closely mounted with the long sides of the Relays facing each other and soldering is performed with infrared radiation, the solder may not be properly exposed to the infrared rays. Be sure to keep the proper distance between adjacent Relays as shown below. -2-2F 2 mm 2. mm Two or more Relays may be closely mounted with the short sides of the Relays facing each other. 8

Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. -E- 34(2)(O) 9