Energy Recovery Laboratory Exhaust

Similar documents
Energy Recovery Laboratory Exhaust

Laboratory Exhaust Systems

Laboratory Exhaust Systems

Laboratory Exhaust Systems

Laboratory Exhaust Systems. Vektor -H High Plume

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Tube Axial Inline Fans

Tubular Centrifugal Fans


2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

HIGH VELOCITY FUME EXHAUST FANS

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Propeller Hooded Roof Fans

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Direct Gas-Fired Heating

Roof Upblast and Sidewall Exhaust

Complete HVAC Capability

High Performance Axial Fans

Mancoolers Models MCY, MCB, MCP

XeteX, Inc. All Rights Reserved.

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

High Performance Axial Fans

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Roof Upblast and Sidewall Exhaust

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

SDL Single-Duct, Low-Height, VAV Terminals

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

READ AND SAVE THESE INSTRUCTIONS

Inline Fans [ 14 ] * UL is optional and must be specified.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Inline and Roof Mounted Fans

TUBULAR CENTRIFUGAL INLINE FANS

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

TSS Single-Duct VAV Terminals

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Air Measuring Products AMD AMS IAQ

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

VANEAXIAL & TUBEAXIAL FANS

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

Filtered Kitchen Supply Packaged Ventilator

forward curved inline duct blowers

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

LINEA Low Discharge Roof Exhausters

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Twin City Fan & Blower

Centrifugal Inline Fans

Energy Recovery Ventilator

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

FAN POWERED TERMINAL UNITS

DESIGN GUIDELINES FANS PAGE 1 of 7

FAN POWERED TERMINAL UNITS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

FDCLP2 Constant Volume Series Flow, Low Profile

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

Dual Duct Variable Air Volume Terminal (Model TDS)

QMXTubular Mixed Flow Product Guide 1

Industry best 5 year fan housing warranty, 1 year motor warranty

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

Climas y Proyectos Leyco, S.A. de C.V.

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

Centrifugal Filtered Supply Roof Blowers

VAHU Vertical Air Handling Unit

The highest energy recovery available.

BAC, BAF, BAH Central Station Air Handlers

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

University of Delaware

Automatic Roof Door Vents

Factory Option Codes L M E S P R D V F F H E

Introduction to Johnson Controls Dampers

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

CH5000 Heat Recovery Ventilator

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Propeller Upblast Roof Fans

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Transcription:

Energy Recovery Laboratory Exhaust Model Vektor -ERS For Vektor-M, MH and MS Systems January 2018

Model Vektor -ERS Greenheck s Vektor -ERS is a pre-engineered laboratory exhaust energy recovery system. In combination with our Vektor-M series blowers (Vektor-M, -MH and -MS), this system is designed to effectively remove contaminated laboratory exhaust and disperse the exhaust high above the roof. Vektor energy recovery exhaust systems utilize run around coils to recover energy from the exhaust airstream and apply the energy to the make-up air system. Vektor-ERS offers a safe and efficient solution to eliminate the possibility of cross-contamination between exhaust and supply airstreams. Vektor-ERS run around coil loops can achieve energy recovery efficiencies up to 50% to lower heating and cooling costs for the laboratory facility. id you know Laboratories typically require 100% outside air with ventilation rates ranging from 6 to 15 air changes per hour. ASHRAE 90.1 indicates that energy recovery to preconditioned make-up air is a suggested energy savings method for laboratories in excess of 5,000 cfm. NFPA 45 states only general exhaust can utilize airto-air energy recovery due to the potential of cross contamination, which is a violation of the standard. Vektor-ERS utilizes air-to-liquid energy recovery, eliminating the possibility of cross-contamination and recovers more exhaust energy. Studies show that approximately 50% of the energy costs associated with operating a laboratory are the result of heating and cooling the makeup air. The addition of energy recovery can significantly reduce this cost. Models Vektor -M, MH and MS are listed for electrical (UL/cUL 705). File No. E40001 2 Type of Heat Transfer Run Around Coil Loop Specifications Sensible Sensible Effectiveness % Up to 50% Location of Exhaust/Supply Airstream Cross-Contamination Cross-Leakage Separate None None Temperature Range -45 to 200 F

Vektor -ERS Features: Four pre-engineered energy recovery plenum sizes Baked phenolic coated coils Insulated double-wall plenum with stainless steel interior Run around coil loop energy recovery Internal or external coil connections Physical separation between exhaust and supply airstreams MERV 8 or MERV 13 filters Single source responsibility Vektor -M Series Fan Features: Nozzle options include high plume, high plume dilution and Variable Geometry Nozzle (VGN) Utilizes an efficient and quiet mixed flow impeller Bifurcated fan housing with motor, drive, and bearings located out of the airstream for safe, easy servicing AMCA licensed for Air, Sound and Induced Flow performance (AMCA 210, 300 and 260) - M AMCA licensed for Air and Sound performance (AMCA 210 and 300) - MH, MS Single source responsibility Performance Ranges VKERS-020 Up to 22,400 cfm VKERS-030 12,500-28,750 cfm VKERS-040 17,000-41,200 cfm VKERS-060 30,000-66,000 cfm Applications University Laboratories Pharmaceutical Companies Biosafety Laboratories Research Facilities Any contaminated exhaust system where reducing energy cost is desired VKERS-040-075-M303 Model Name Cabinet Size 020, 030, 040, 060 Cabinet Height 75, 90, 110 Fan Type MH, M, MS Number of Fans 1, 2, 3 Fan Size 15 22 30 40 54 18 24 33 44 20 27 36 49 3

ERS System Operation The Vektor-ERS uses a corrosion-resistant run around liquid coil loop to recover energy from the laboratory exhaust airstream and transfer the energy to the laboratory make-up air. The energy transfer preheats make-up air in the winter and precools make-up air in the summer. iluted High Plume Exhaust Reheat Coil Cooling Coil Vektor Energy Recovery Coil Filters Make-Up Air Unit Energy Recovery Coil Filters VAV Bypass Air Glycol Loop Pump Outside Air Supply Exhaust Safe, Reliable, Cost-Effective The run around coil loop is the preferred method of recovering energy from hazardous lab exhaust because separation is maintained between the exhaust and supply airstreams, eliminating the concern of crosscontamination. The exhaust coil is corrosion-resistant coated and in subfreezing climates, a percentage of glycol is added to depress the freezing point of the circulated fluid. The Vektor-ERS system also eliminates the need to duct large volumes of supply and exhaust air to a common point which is required with other energy recovery systems reducing the Vektor-ERS system installed cost and improving economic payback. Significant Energy Savings The Vektor-ERS can significantly reduce a laboratory facility s heating and cooling load. The tables illustrate preheating and precooling temperatures of make-up air and load reductions for various cities based on standard weather bin data. Greenheck offers a complete thermodynamic and economic analysis of a Vektor-ERS for your specific project. Winter / Preheated Summer / Precooled Outdoor Air Temperature ( F) -10 0 10 20 30 85 95 105 Preheat Air Temperature ( F) 26.9 32.4 37.9 43.4 48.9 79.2 84.7 90.2 Preconditioning of make-up air based upon 72 exhaust and 45% energy recovery efficiency. City BTUH Saved Annually Net ollars Saved Heating Cooling Annually Atlanta 7,556,153 (1,657,890) $42,303 Boston 8,927,100 (1,657,890) $77,779 Chicago 13,677,593 (1,657,890) $86,261 Cincinnati 13,794,495 (1,594,125) $75,385 Portland 3,528,330 (1,647,263) $59,063 Syracuse 9,458,475 (1,594,125) $90,887 Energy saving shown for annual operation, at outdoor TMY2 bin data for the specified location. Systems operating at 50,000 cfm, equal supply and exhaust; $0.1/kWh, and $1.75/MMBtu, assuming 80% heating efficiency. NOTE: kwh and MMBtu costs may vary by locale. 4

imensions, Weights and Configurations Bypass Air Inlet (typical) for VAV Systems E C B Inlet Horizontal Airflow A A Inlet Vertical Airflow B A (Length) B (Width) C Weight** (pounds) Fan Section Height* Coil Section Height* Maximum Minimum Maximum Minimum Maximum 75 90 110 VKERS-020 120 127 169 70 70 3564 4386 NA VKERS-030 154 127 181 70 84 4042 4644 NA 75 90 110 VKERS-040 206 147 181 70 84 5117 5824 NA VKERS-060 270 147 181 70 84 6609 7515 8001 E Overall System Height* Fan Size 15 18 20 22 24 27 30 33 36 40 44 49 54 Maximum 151 161 180 175 183 200 209 203 223 230 250 263 272 imensions shown in inches. *Curb not included ** Approximate weight based on maximum coil size (less coil fluid) and maximum number of filters. Fans, bypass plenums and roof curbs are not included. Obtain from CAPS (Computer Aided Product Selection). Available Configurations 1x1 2x1 3x1 Vektor-ERS Selections by Cabinet, Fan Quantity and Fan Size Bypass Air Inlet (typical) for VAV Systems 1x1 2x1 3x1 VKERS-020 15-36 15-22 Not available VKERS-030 30-44 20-33 15 VKERS-040 36-54 22-54 18-27 VKERS-060 Not availble 30-54 24-40 E Consult factory for additional configuration options. C B Inlet Horizontal Airflow 5

Vektor -ERS Standard Construction Features A Cabinet Construction Coated steel exterior with stainless steel interior ouble-wall construction with two-inch foam filled panels Stainless steel fasteners Bottom or side inlet locations Hinged access door with tooled entry handles B Coil Construction Aluminum fins with copper tubing, corrosion-resistant baked phenolic coated Stainless steel casing, corrosion-resistant baked phenolic coated Sized for maximum velocity of 500 ft/min Six row coils, eight fins per inch (standard) Eight row coils, ten fins per inch (optional) Rated in accordance with AHRI 410 UL and ETL recognized Leak tested under water at 450 PSIG dry nitrogen E C Filters Two-inch up to 35% disposable pleated filters, MERV 8 (0.24 inch wg pressure drop at 500 ft/min) Four-inch up to 65% disposable pleated filters, MERV 13 (0.40 inch wg pressure drop at 500 ft/min) G Fan Plenum Curb 12-gauge welded steel, coated with LabCoat Insulated Minimum of 12 inches high Gasket provided for curb seal esigned to withstand 125 mph wind-load rating without the use of guy wires G Vektor Sure-Aire another energy saving system from Greenheck Continuously monitor critical laboratory fan exhaust and building exhaust flow without airflow probes in the exhaust airstream. Benefits of the Sure-Aire system: Fan Flow Measurements Continuously measures critical fan and laboratory exhaust flow Reports values to Building Automation System (BAS) No system effect or resistance to airflow No additional pressure loss Output to No increase in fan RPM, sound or brake horsepower BAS No additional energy cost for the building owner No probe corrosion to cause fan failure 6

E Fan Construction Efficient and quiet mixed flow impeller technology Bifurcated housing with motor, belt and bearings out of the airstream Welded steel construction, coated with LabCoat Belt or direct drive Totally enclosed fan cooled, premium efficient motors F Fan Plenum Construction Single-wall construction coated with LabCoat ouble-wall construction with 2 in. insulation, stainless steel liner Exterior steel walls coated with LabCoat F A B C G amper Features Isolation damper completely accessible from exterior of system Bypass damper(s) are sized to match system requirements Welded steel, Hi-Pro Polyester coated airfoil blade design H H Coil Cabinet Curb 12-gauge welded steel, coated with LabCoat Insulated 12 inches high Gasket provided for curb seal esigned to withstand 125 mph wind-load rating without the use of guy wires Vektor ERS Options and Accessories Magnehelic Gauge To measure air pressure drop across the filters indicating filter loading. Vapor Tight Lights Moisture and corrosion-resistant construction with no exposed parts. Energy-efficient, compact fluorescent lamps. 7

Family of Lab Exhaust Systems High Plume - Effective means of creating a discharge plume height to prevent re-entrainment of chemical exhaust fumes into make-up air systems. Vektor-H High Plume ischarge Nozzle Compact design / sealed airstream components Up to 26,000 cfm and 4 in. wg Vektor-MH High Plume Nozzle Mixed flow wheel / bifurcated housing Compact design Up to 47,000 cfm and 11 in. wg Vektor-CH High Plume Nozzle Up to 56,000 cfm and 12 in. wg High Plume ilution - Fan design that entrains and mixes outside ambient air into the exhaust airstream prior to exiting out the windband discharge. Potentially hazardous exhaust or exhaust fumes are diluted and dispersed quickly. Vektor-M High Plume ischarge Nozzle with Entrainment and ilution Mixed flow wheel / bifurcated housing Compact design Up to 83,000 cfm and 11.5 in. wg Vektor-C High Plume ischarge Nozzle with Entrainment and ilution Highest efficiency / easy service design Up to 122,000 cfm and 13.5 in. wg High Plume Variable Geometry Nozzle (VGN) - The discharge area automatically adjusts to maintain a constant discharge velocity and remain compliant to design codes. VGN maximizes effective plume heights during periods of reduced flow and lower discharge velocity fixed nozzles. Vektor-HS VGN discharge nozzle technology Variable volume flow constant velocity discharge Up to 26,000 cfm and 3.5 in. wg Vektor-MS VGN discharge nozzle technology Variable volume flow constant velocity discharge Mixed flow wheel / bifurcated housing Up to 32,000 cfm and 10 in. wg Vektor-CS VGN discharge nozzle technology Variable volume flow constant velocity discharge Up to 32,000 cfm and 10 in. wg Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.LAB.1009 R5 1-2018 SN Copyright 2018 Greenheck Fan Corp.