Thermography Report. Inspection Site: Lucky Mining Co. Rocky Rd Smithville, NSW. Requested By: John Seemore. Date of Inspection:

Similar documents
2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9

THERMOGRAPHY REPORT ELECTRICAL

Fault Summary The following table is a summary of faults or items featured for your information

Thermal Imaging Infrared Survey. Report. Report. Thermography Inspection at ABC Company.

Substation inspection guidelines Mark B. Goff, P.E.

BUZZI UNICEM USA PRESIDENT S ISLAND TERMINAL MEMPHIS, TENNESSEE

SYSCO INDIANAPOLIS INDIANAPOLIS, INDINA

SYSCO CENTRAL CALIFORNIA MODESTO, CALIFORNIA



SIDEWINDER DRILLING RIG 219 LA SALLE, TEXAS

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

Substation Equipment (Bushings)

INFRARED THERMOGRAPHY:

Low Voltage Systems MNS platform

SIDEWINDER DRILLING RIG 127 MIDLAND, TEXAS

Thermal Patterns Associated with Infrared Inspection of Electrical Systems

S H A D E S ELECTRICAL DB MANUFATURING

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Avid Electrical Services

ATevo SERIES BATTERY CHARGER

INFRARED INSPECTION REPORT

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

J1 Plug Pin Identification

J1 Plug Pin Identification

J1 Plug Pin Identification

DSEULTRA DSE6000 Quick Start Guide Document Number

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Thermographic Inspection at SMALLVILLE DPW 123 ANY WAY SMALLVILLE, CA PETER PLEIN

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Company Name City, State. Thermographic Study (date) Prepared By: L&S Electric, Inc. PO Box 740 Schofield, WI

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Chapter 6 Generator-Voltage System

Uninterruptible Power System

SYSCO RDC SOUTH ALACHUA, FLORIDA

AT EVO SERIES BATTERY CHARGER

Instruction Manual. Q Series 2 Motor Control Modules - OEM

NC PV DG Program SEPA Presentation. December 15, 2011

Designed for ease of integration with automation systems

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

Switchgear and Distribution Systems for Engineers and Technicians

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

Product Overview. Soft Starters Motor Protection Control and Measurement. Solcon Industries Ltd.

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

SYSCO OKLAHOMA LLC NORMAN, OKLAHOMA

AUTOMATION AND CONTROL TRADE 19 TAR SANDS

Battery, Mounting and Cables - Battery and Cables Description and Operation

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

ABB Drive Services Your choice, your future

ABB Services for Low Voltage equipment Your choice, your future

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

Flight Systems. Replacement for KASSEC DESCRIPTION

30 KW / 40 KVA POWERED by

Powerware Master Modbus

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

V. Design, Application, Maintenance & Operation Technical Requirements

Redundant Control System

Introduction. Main fuseboard. Circuit breaker. Engine compartment fuses. Luggage compartment fuses Four door cars. Two door cars.

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

ATA 49 AUXILIARY POWER UNIT

Eilat, 11/2017. Cost Effective switchgear Modernization solutions

Low and medium voltage service. Power Care Customer Support Agreements

MODEL SCA Installation and Operation Manual Important:

Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2)

Series Motor Protection

Uninterruptible Power System

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

AT SERIES EVO BATTERY CHARGER

MaxSG Low Voltage Switchgear

SENTINEL BATTERY MONITORING

64 KW / 80 KVA POWERED by

Conveyor Condition Monitoring. Increase uptime, decrease damage, plan repairs, avoid disaster

4 Redundant Control System

130 KW / 165 KVA POWERED by

ROBICON W120 enclosed drive

Function of Preglow System

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Case Study on On EHV Circuit Breaker Flashover NTPC-SINGRAULI

SDS Enclosed Star-Delta Starter User Guide

55 KW / 70 KVA POWERED by

204 KW / 254 KVA POWERED by

Powered by Safety. Powell Service Division Services Overview

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MNS PDUpro Intelligent power distribution unit

Grounding Systems. Resistance. Resistance Grounding Systems Contents

Two Recent Case Studies in the Mining Industry

DASSAULT AVIATION Proprietary Data

Motor Protection. Presented By. Scott Peele PE

TIME REQUIREMENT GUIDE (TRG)

Transcription:

Thermography Report Inspection Site: Lucky Mining Co. Rocky Rd Smithville, NSW Requested By: John Seemore Date of Inspection: 27-10-2006 Reference Number: 2710061 Thermographer: John Crawford Thermal Imaging Camera: Make: FLIR Model: ThermaCAM E45 Serial: 24307146

INSPECTION GENERAL INFORMATION This thermographic inspection is designed to assess the performance of all switchgear on site and to highlight any areas which require attention. Recommendations listed within this report are given only within our area of expertise and we recommend you discuss the implementation of remedial works with your maintenance service provider. Scope Infrared Thermal Scanning of all electrical switchgear and associated conductors to detect evidence of equipment operating near or above rated temperatures. Load readings are also taken of prospective faults to assist in the accurate diagnosis of the prospective fault. A detailed log of inspected assets is provided which includes a Pass or Fail status. Those items failing the inspection are reported on through a thermal and digital image, a priority rating & possible recommended action. An initial scan of all items is carried out with the Infrared Radiometer set to alarm at temperatures above 40 o C. Items displaying temperatures above 40 o C are further investigated based on application, equipment type, load measurement & spot temperature readings. Overview of Fault Priority Ratings 0 No abnormality No Action 1 Alert To be monitored rescan when recommended 2 Severe Repair at scheduled shutdown, not longer than 30 days 3 Critical Repair immediately or as soon as possible 4 Immediate Notification Shutdown & repair immediately 2

Location: Motor Control Room Page: 3 Section: Relay Compartment Priority: 2 Equipment: Mains indicator lamp, white phase Item: 3 63.1 C Ar1 40 22.4 23.6 C Ar1: Max 59.2 C Pilot lamp assembly should be replaced. Priority Level 2 Repair at next scheduled shut down, no later than 1 month. 3

Location: Motor Control Room Page: 4 Section: MDB-1 Section 1 Priority: 2 Equipment: 1amp Pan A & Pan B Fault Limiting Fuses Item: 10 Ar2 Ar1 69.2 C Ar3 Ar4 45.8 68.6 C Ar1: Max 76.4 C Ar2: Max 76.8 C Ar3: Max 72.5 C Ar4: Max 71.1 C The fault current limiting fuses are operating at excessive temeratures considering the operating load of 100 amps per phase. The rating of the fuses are 1amps. Priority level 2, the fuses & fuse carriers should be replaced at the next scheduled shutdown. 4

Location: Motor Control Room Page: 5 Section: Cable Zone Priority: 1 Equipment: CR3 sub-main circuit breaker terminations Item: 13 Sp2 Sp3 62.9 C 40 38.3 42.5 C Sp2 49.1 C Sp3 47.7 C All 3 phases are equally loaded at 540amps per phase, phase temperatures should be equal. Priority Level 1, monitor condition & re-scan in 3 months. 5

Location: Workshop Distribution Board Page: 6 Section: D.B.W.S. Priority: 2 Equipment: Precoat plant circuit breaker Item: 15 Ar1 68.1 C Li1 Sp2 40.7 49.7 C Sp2 43.3 C Li1: Max 63.5 C Ar1: Max 64.6 C C 68 66 64 62 58 56 54 52 48 46 44 42 Cursor Min Max Li1-42.2 63.5 Circuit breaker rating is 25amps, sub circuit cable size is 2.5mm, load current is 21amp per phase. The cable size is under rated for the existing load, either the load & circuit breaker size needs to be reduced or the cable size increased. Priority Level 2, remedial work should be carried out next scheduled shutdown. 6

Location: Main Switch Board Page: 7 Section: Priority: 2 Equipment: Main Switch MDB-1 Item: 20 76.4 C Sp4 Sp2 70 Sp3 Li1 Sp5 45.2 71.3 C Sp2 65.9 C Sp3 61.3 C Sp4 57.6 C Sp5 59.4 C Li1: Max 71.9 C C 76 74 72 70 68 66 64 62 58 56 54 52 48 46 Cursor Min Max Li1-65.5 71.9 Blue phase bus bar on the circuit breaker load side is operating approx. 10 deg C higher than the adjacent 2 phases, load per phase is 1180amps & balanced within 4%. The temperature profile indicates the temperature rise origin to be either at the circuit breaker/bus bar termination point or internal to the circuit breaker. It is recommended the circuit breaker be removed, inspected & all termination points dressed. The breaker should then be recommissioned & monitored Priority Level 2, remedial work should be carried out next scheduled shutdown. 7

LOG OF INSPECTED ASSETS LOCATION EQUIPMENT ITEM RESULT NUMBER Motor Control Room PLC Cubicle PLC-1 1 P Motor Control Room Cable termination compartment 2 P Motor Control Room Relay Compartment 3 F Motor Control Room MCC-1 4 P Motor Control Room Contactor Compartment No.2 5 P Motor Control Room VSI Crusher CR3 6 P Motor Control Room Crusher Starter CR2 7 P Motor Control Room Crusher Starter CR1 8 P Motor Control Room Circuit Breaker Compartment 9 P Motor Control Room MDB-1 Section 1 10 F Motor Control Room MDB-1 Section 2 11 P Motor Control Room MDB-1 Section 3 12 P Motor Control Room MDB-1 cable zone 13 F Motor Control Room Distribution Board DBX-1 14 P Workshop Workshop Distribution Board DBWS 15 F Main Office Office Distribution Board 16 P Main Switch Board Mains Connection Section 17 P Main Switch Board C.T. Section 18 P Main Switch Board MCR Sub-main connection section 19 P Main Switch Board Main switch MDB-1 20 F Main Switch Board Local D.B. mainswitch 21 P Main Switch Board Local D.B. section 22 P F Failed inspection P Passed Inspection NIO Equipment Not In Operation at time of inspection 8

ACTION TAKEN: BY: DATE: 9