M Ball Valve Linkage Kit

Similar documents
VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

M x Series Valve Linkage Kits

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

M x Series Valve Linkage Kits

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

M x Series Valve Linkage Kits

M Ball Valve Linkage Kit

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

M x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators

VA-4233-GGx Series Electric Valve Actuators

M Valve Actuator Weather Shield Kit

VG7000 Series Bronze Control Valves

VA-7450 Series. Electric Valve Actuators

PP1 Series Piping Packages for VG1000 Series Ball Valves

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

V-9502 Series Pneumatic Valve Actuator Positioners

VA-8020 Floating Valve Actuator

VA9104-xGA-3S Series Electric Non-Spring Return Valve Actuators

VA-4233-AGx Series Electric Valve Actuators

M9206-GGx-2S Series Proportional Electric Spring Return Actuators

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

COMMERCIAL. VA(M)S-70 Series Installation Instructions

M9210-xxx-3 Electric Spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Installation Instructions

M Remote Mounting Kit

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

TE-6300 Series Temperature Sensors

VA-4233-GGx Series Electric Valve Actuators

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

M9300 Series Switch Kits

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

M9000-3xx Series Weather Shield Enclosures

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

M9220-xxx-3 Electric Spring Return Actuators

VA9203-AGx / VA9203-Bxx / VA9203-GGx

TE-6300 Series Temperature Sensors

RD-2000 Round Control Dampers

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

M9300 Series Potentiometer Kits

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

D-4070 Two Stage Pneumatic Actuator

VG2000 Series Cast Iron Flanged Globe Valves

M9216 Series Electric Spring Return Actuators

AV-8020 Series Floating Control Actuated Valve

Damper Actuator Installation

F61 Series Standard Flow Switches

ID-141x 12-Gauge Hat Channel Industrial Damper

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

PC-125x Counter-Balanced Backdraft Damper

VA-715x Electric Valve Actuator

M100F Incremental Motor Actuator R81F Interface Board

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

M Remote Mounting Kit

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

BD-1600 Balancing/Zone Control Damper

M9203-xxx-2(Z) Series Electric Spring Return Actuators

M9109 Series Electric Non-spring Return Actuators

VG1000. VG1000 Ball Valve Assemblies. M92x6 Spring Return Actuator

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-xGx-2 Series Electric Non-Spring Return Actuators

VA9905 Actuator and VG1600 Series Six-Way Valves

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

M Remote Mounting Kit

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

P70, P72 and P170 Series Controls for High Pressure Applications

TM-11x1 Series Room Temperature Module

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

VG1000 Series Forged Brass Ball Valves

VG7000 Series Bronze Control Valves

M9300 Series Electric Non-Spring Return Actuators

V46 Series Pressure-Actuated Water-Regulating Valves

RA-2000 Airflow Measuring System

System 350 P352AB Electronic Pressure Control Series

VG9000 Flanged Valves

SD-1250 and SD-1600 Series Smoke Dampers

P70, P72, and P170 Series Controls for High Pressure Applications

VG7000 Valve Linkage for M100 Series Motor Actuators

VG6000 Series Forged Brass Valves

F261 Series Fluid Flow Switches

VA9208-xxx-xx Series Electric Spring-Return Actuators

VD-1600 Series Volume Control Dampers

VA9208-xxx-xx Series Electric Spring Return Actuators

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

Series P74 Differential Pressure Controls, without time delay

VG7000 Series Bronze Control Valves

Barbara, Here is the list of items. I numbered the attachments to match with the numbers below.

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

VG1000 Series Flanged Ball Valves Catalog Page

COMMERCIAL. D(M)S24-70 Series Installation Instructions

P70, P72, and P170 Controls for Low Pressure Applications

Transcription:

M9000-551 Ball Valve Linkage Kit Installation Instructions Part No. 34-636-1816, Rev. B Issued July 6, 2011 Supersedes February 7, 2006 Applications The M9000-551 Ball Valve Linkage Kit (Figure 1) is designed to mount an M9104 Series actuator to a VG1000 Series ball valve, either the VG1241, VG1245, VG1841, or VG1845 Series 1/2, 3/4, or 1 in. (DN15, DN20, or DN25) ball valve. (See the Technical Specifications table.) Refer to the QuickLIT Web site for the most up-to-date version of this document. Drive Shaft Location for M4x60 Machine Screw Handle IMPORTANT: The M9000-551 Ball Valve Linkage Kits are intended to control hot water and chilled water flow under normal equipment operating conditions. Where failure or malfunction of the M9000-551 Ball Valve Linkage Kit could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the M9000-551 Ball Valve Linkage Kit. Figure 1: Parts Included with M9000-551 Linkage Kit 10-24 Thread Forming Screw Adaptor Bracket M9000551.des Installation Parts Included adaptor bracket drive shaft handle M4 x 60 machine screw two No. 10-24 thread forming screw installation instructions Barrier Machine Screws Flange Nuts Drive Shaft Figure 2: Parts Included with optional M9000-561 Thermal Barrier Kit Special Tools Needed T-20 TORX driver 1/4 in. flat-blade screw driver M9000-551 Ball Valve Linkage Kit Installation Instructions 1

FIG:M9104dims Dimensions See Figure 3 and Table 1 for the dimension drawings of the Spring Return M9104 Actuated VG1241, VG1245, VG1841, and VG1845 Series National Pipe Thread (NPT) End Connection Ball Valve. Minimum Clearance Required 3-1/2 (89) 2-13/16 (71) 5-1/2 (140) A F Port Marking Locations C C A B C B B E E G D Two-Way Valve Figure 3: Field-Installed M9104 Series Electric Actuator Dimensions, in. (mm) Table 1: M9104 Actuated VG1241, VG1245, VG1841, and VG1845 Series NPT Ball Valve Dimensions, in. (mm) Valve Size A B C D E F G in. (DN) 1 1/2 (DN15) 3-7/8 (98) 21/32 (17) 1-7/32 (31) 5-7/64 (129) 2-33/64 (64) 11/32 (9) 1-1/4 (32) 3/4 (DN20) 3-7/8 (98) 21/32 (17) 1-7/32 (31) 5-7/32 (133) 2-51/64 (71) 11/32 (9) 1-13/32 (36) 1 (DN25) 3-61/64 (100) 3/4 (19) 1-19/64 (33) 5-9/16 (141) 3-13/32 (87) 11/32 (9) 1-11/16 (43) 1. Port A must always be connected to the coil. Three-Way Valve Two-Way Valve Three-Way Valve Table 2: M9104 Actuated VG1271, VG1275, VG1871, and VG1875 Series Sweat Ball Valve and M9104 Actuated VG1291, VG1295, VG1891, and VG1895 Series Press Ball Valve Dimensions, in. (mm) Valve Size A B C D E F G in. (DN) 1 2-Way 3-Way 1/2 (DN15) 3-7/8 (98) 21/32 (17) 1-7/32 (31) 3/4 (DN20) 3-7/8 (98) 21/32 (17) 1-7/32 (31) 1 (DN25) 3-61/64 (100) 3/4 (19) 1-19/64 (33) 1. Port A must always be connected to the coil. 5-45/64 (145) 5-57/64 (150) 6-1/8 (156) 6 (152) 2-33/64 (64) 11/32 (9) 2-3/16 (55) 6-9/32 (159) 6-11/16 (169) 2-51/64 (71) 11/32 (9) 2-15/32 (62) 3-13/32 (87) 11/32 (9) 2-27/32 (72) 2 M9000-551 Ball Valve Linkage Kit Installation Instructions

FIG:M9104X_dims See Figure 4 and Table 3 for dimension drawings of the Non-Spring Return M9104 Actuated VG1241, VG1245, VG1841, and VG1845 Series NPT End Connection Ball Valve with optional M9000-561 Thermal Barrier installed. 3-1/2 (89) Clearance Required 2-13/16 (71) 5-1/2 (140) A Port Marking Locations Table 3: M9104 Actuated VG1241, VG1245, VG1841, and VG1845 Series NPT Ball Valve with Optional M9000-561 Thermal Barrier Installed Dimensions, in. (mm) Valve Size A B C D E F G in. (DN) 1 1/2 (DN15) 5-11/32 (136) 21/32 (17) 1-7/32 (31) 5-7/64 (129) 2-33/64 (64) 11/32 (9) 1-1/4 (32) 3/4 (DN20) 5-11/32 (136) 21/32 (17) 1-7/32 (31) 5-7/32 (133) 2-51/64 (71) 11/32 (9) 1-13/32 (36) 1 (DN25) 5-27/64 (138) 3/4 (19) 1-19/64 (33) 5-9/16 (141) 3-13/32 (87) 11/32 (9) 1-11/16 (43) 1. Port A must always be connected to the coil. D Figure 4: Field Installed M9104 Series Electric Actuator Dimensions with M9000-561 Thermal Barrier, in. (mm) M9000-551 Ball Valve Linkage Kit Installation Instructions 3

FIG:VG1000 FIG: drvshft Mounting Mount VG1000 Series Ball Valves with the actuator at or above the centerline of the horizontal piping, as shown in Figure 5. This position prevents water or condensation from flowing into the actuator. To minimize heat transfer, wrap the valve and piping with insulation. Allow sufficient clearance to remove the actuator. 2. Mount optional M9000-561 Thermal Barrier to the valve if fluid temperature exceeds 212 F (100 C). See the Mounting the Thermal Barrier section for more information. Note: M9104 Series Electric Actuators require at least 3-1/2 in. (89 mm) of clearance above the actuator. 3. Remove the metal anti-rotation feature, located at rear tab. 4. Remove the actuator hub set screw, if present. 5. Insert the linkage drive shaft into the actuator output hub as shown in Figure 7. Figure 5: Mounting Positions for Chilled Water and Condensing Atmosphere Applications M9000-550 ii03.cdr IMPORTANT: Mount the actuator within 90 of the vertical position above the valve body. Failure to do so may permit water or moisture to travel down the valve stem, damaging the actuator and voiding the warranty. IMPORTANT: In steam applications, install the valve with the stem horizontal to the piping. Failure to follow this precaution may shorten the life of the actuator. Installing the M9104-xGx-xS Series Electric Actuator To install the M9104-xGx-xS Series Electric Actuator: 1. Turn the valve stem to the position outlined in Figure 6. Figure 7: Installing the Drive Shaft 6. Attach the linkage adapter bracket to the bottom plate of the actuator with the two 10-24 thread-forming screws (Figure 8). Hand-tighten the screws using a T-20 TORX driver or a 1/4 in. flat blade screw driver. Recommended torque is 13.5 to 16.5 lb in (1.5 to 1.9 N m). 2 Way 3 Way Figure 6: Positioning the Valve Stem FIG: adptrbrckt Figure 8: Installing the Adapter Bracket 4 M9000-551 Ball Valve Linkage Kit Installation Instructions

PortBtoC PortAtoC PortAtoB 7. Place the handle on top of the linkage drive shaft as shown in by Figure 9. The handle is keyed and mounts only in one orientation. For two-way valves, position the stem to open the valve as shown in Figure 10. For three-way valves, position the stem to open the valve from Port A to Port C as shown in Figure 11. Port A Inlet Port B Outlet FIG: hndl Two-way Shown in Open Position Figure 10: VG1000 Series Two-Way Ball Valve (Port A Connected to Port B) Figure 9: Installing the Handle 8. Insert the M4x60 long machine screw into the hole in the handle. Use a T-20 driver or 1/4 in. flat blade screw driver to drive the screw into the linkage drive shaft until the screw sits below the top of the handle. 9. Before installing the actuator and linkage assembly on the VG1000 Series ball valve, rotate the valve stem manually several times using an adjustable wrench to break the torque that may have built up during long-term storage. Then, rotate the valve stem to position the valve in the required position. Two Way Valves: When the marking of the valve stem is parallel or in line with the direction of flow (Figure 10), the valve is open from Port A (inlet) to Port B (outlet). Three Way Valves: When the valve stem is in the position shown in Figure 11, the valve is open and flow is established from Port A (coil) to Port C (common) with Port B (bypass) blocked. As the actuator rotates the valve 90 degrees in the clockwise direction, the stem appears as shown in Figure 12. In this position, Port A (coil) is blocked, and flow is established between Port B (bypass) and Port C (common). 10. Depress the gear release button and position the actuator output hub in the fully counterclockwise position as viewed from the top of the actuator. Port A Coil Port B Bypass (blocked) Port C Common Figure 11: VG1000 Series Three-Way Ball Valve (Port A Connected to Port C) Port A Coil (blocked) Port B Bypass Port C Common Figure 12: VG1000 Series Three-Way Ball Valve (Port B Connected to Port C) M9000-551 Ball Valve Linkage Kit Installation Instructions 5

11. Install the actuator and linkage assembly over the ball valve mounting flange, as shown in Figure 13. Depending on the application, position the assembly in any of four 90 increments on the valve. Figure 14: Installing the Drive Shaft into the Thermal Barrier Figure 13: Coupling the Actuator to the Valve Note: For proper operation, the actuator must drive the valve clockwise to close Port A, when viewed from above the valve. 12. Using a T-20 TORX driver or 1/4 in. flat-blade screw driver, fasten the actuator to the valve. Recommended torque is 8 to 12 lb in (0.9 to 1.4 N m). FIG: CUPLACT 2. Rotate the drive shaft to align marks on the top of the thermal drive shaft with matching marks on the valve stem. 3. Mount the thermal barrier onto the valve using the four included M5x16 mm machine screws and four M5 flange nuts. Tighten the screws to a recommended torque of 21 to 25 lb in. (2.4 to 2.8 N m) (Figure 15). IMPORTANT: Do not overtighten the mounting screw. Overtightening the mounting screw may strip the threads. Mounting the Thermal Barrier Figure 2 shows the optional M9000-561 Thermal Barrier. To mount the optional thermal barrier: 1. Install the thermal barrier drive shaft into the thermal barrier by aligning the tab on the drive shaft with the slot on the thermal barrier (Figure 14). Figure 15: Installing the Barrier 4. Proceed to actuator mounting instructions. Follow the same steps as mounting directly to the valve when mounting the actuator to the thermal barrier. Note: Depending on your application, you may position the assembly in any of the four 90 increments on the valve. FIG:in_act 6 M9000-551 Ball Valve Linkage Kit Installation Instructions

Wiring For proper actuator wiring and commissioning instructions, refer to the following documentation: M9102-AGA-2S and M9104-AGA-2S Series Electric Non-Spring Return Actuators Installation Instructions (Part No. 34-636-1220) Technical Specifications M9000-551 Ball Valve Linkage Kit Fluid Temperature Limits Ambient Conditions M9104 Material VG12x1 and VG18x1 Series VG12x5 and VG18x5 Series Standard Operating Storage Shipping Weight M9000-551 Linkage Kit M9000-561 Thermal Barrier Kit Fluid Temperature Limits Material VG12x5 and VG18x5 Series with M9000-561 Thermal Barrier Installed Shipping Weight M9000-561 Thermal Barrier M9102-AGA-3S and M9104-AGA-3S Series Electric Non-Spring Return Actuators Installation instructions (Part No. 34-636-1433) Repair and Replacement Do not attempt to field repair the M9000-551 Ball Valve Linkage Kit components. For replacement parts, see Technical Specifications and contact your nearest Johnson Controls representative. 23 to 203 F (-5 to 95 C); Not Rated for Steam Service -22 to 212 F (-30 to 100 C); Not Rated for Steam Service -4 to 140 F (-20 to 60 C); 90% RH Maximum, Noncondensing -20 to 150 F (-29 to 66 C); 90% RH Maximum, Noncondensing Glass-Reinforced Thermoplastic Resin; Suitable for use in other environmental air space (plenums) in accordance with Section 300.22(c) in the National Electric Code. 1.5 lb (0.7 kg) -22 to 284 F (-30 to 140 C) Water; 15 psig (103kPa) at 250 F (121 C) Saturated Steam Glass-Reinforced Thermoplastic Resin; Suitable for use in other environmental air space (plenums) in accordance with Section 300.22(c) in the National Electric Code. 1.5 lb (0.7 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2011 Johnson Controls, Inc. M9000-551 Ball Valve Linkage Kit Installation Instructions 7 Published in U.S.A. www.johnsoncontrols.com