27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

PSU EN54-4 Power Supplies

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

K25000 & KD25000 Series

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

Installation Instructions

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

AWZ 200. AWZ 13,8V/2A/7Ah/L

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

Installation Instructions

User Manual. Solar Charge Controller 3KW

New Batteries Directive Version 4 December 2009

Switching DC Power Supply

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

ACCESSORY KIT INSTALLATION INSTRUCTIONS

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

24V 3A EN54 Ancillary Power Supply

c-go 24V/6A 24V/8A 24V/12A

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

Multi-Mover Charger for model L25

EC400 Power Control System

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Phoenix Inverter

CX-SERIES ADVANCED BATTERY CHARGER

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

TRAC-Station BT Installation Instructions

Industrial Power Supplies

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

AC/DC Converter MBP250-2A13D13M

DEEP SEA ELECTRONICS PLC

HPSB 2512B v.1.0 HPSB 13,8V/2A/7Ah Buffer, switch mode power supply unit.

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

User Manual Rittal PMC UPS 6kVA

##CFG BWOP Manuals## 24v Emergency Power Unit Installation & Instructions for Use

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

BNC BNC 12V/8x1A. Switch mode power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

EASY CHARGE Weather-resistant fixed mount Battery Charger

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Operating Instructions

Power supply kit (70 W)

Self-Testing Industrial Series

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Central Battery Systems Loadstar AC/DC Systems

- Wiring Brochure Zone Manager 335

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

- Wiring Brochure Zone Manager 336

DEEP SEA ELECTRONICS PLC

EC225 Power Control System

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

INSTALLATION INSTRUCTIONS

CENTRAL BATTERY UNIT. Installation and maintenance instructions TKT3122

Sentry Battery Charger. Installation and Operations Manual Section 75

Uninterruptible power supply Supply MEg101.4

Emergency lighting units EM converterled

EC400 / EC450 series Power Control System

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

Product Installation Document

GENIUS-II Series Owner's Manual

CAUTION CM-SE CM-S21 CM-S41

EC200 ELECTRONIC CONTROL SYSTEM

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

SCCP PWM Charge Controller/Load Manager Owner s Manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Spectron Industrial Series

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Instruction Manual. Q Series 2 Motor Control Modules - OEM

User s Manual. Automatic Switch-Mode Battery Charger

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

Uninterruptible Power System

SMP3CTX Series Power Supply/Charger

EMERGENCY VEHICLE BATTERY MANAGER PS2024

User Manual Solar Charge Controller 3KW

Transcription:

1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y # for 8Ah and up to 1.0A* Continuous Load Current GEN3-18-y # for 18Ah and up to 1.5A* Continuous Load Current FEATURES High efficiency cost effective power supply suitable for use in systems designed to comply with PD6662:2010 and EN50131-6:2008 Grade 3 and Environmental Class II. Rated to provide continuous current to load for systems requiring 12h standby from a battery. Three independent output signals are provided for loss of mains fault (EPS**), battery fault (APS**), and power supply fault (GEN). Comprehensive self-diagnostics can detect blown output and battery fuses, battery fail, low battery voltage, battery missing and low output voltage. The PSU incorporates intelligent battery management comprising active full load battery testing, low battery voltage detection and deep discharge protection to ensure that the battery is not permanently damaged through excessive discharge. A brownout filter ensures that short mains voltage dips do not create a false loss of mains alarm. Two LEDs assist with quick and easy installation by showing presence of mains, correct battery charging or a fault condition. Comprehensive protection is built-in as standard including mains transient filtering, electronic output overload protection and fuses on the load and battery outputs. PD662:2010 and EN50131-6:2008 Type A Grade 3 Environmental Class II Compliant Intelligent active battery monitoring Low quiescent battery monitoring current during standby operation Fault signals for loss of mains, battery fail and power supply fault deep discharge protection overvoltage protection Protection against reverse battery connection Electronic overload protection shuts down output until overload or short circuit is removed (while on mains power) LED for comprehensive diagnostics Mains transient suppression and brown-out filter Fully enclosed lid and removal from wall tamper circuit. # y Denotes enclosure size see overleaf * See table overleaf to determine continuous standby battery current available for given standby times **EN50131 Definitions: EPS = External Power Source APS = Alternative Power Source

2 SPECIFICATION Mains Input Rated Voltage /(Operational Voltage) Frequency Input current Fuse Output Voltage at full load Mains power standby Ripple Fuse: Load Continuous Output Current* Mains for 12 hours 30 hours 60 hours 100-240Vac /(90 265Vac) 50/60Hz GEN3-08 & GEN3-18 < 1.0A at full load T2A 20mm HRC GEN3-08-y GEN3-18-y 13.2 14.2Vdc(13.8Vdc nominal) 9.8 13.0Vdc <400mV pk pk max @ Rated Voltage F1.0A F1.6A F1.0A F1.6A 1.0 A 1.5A 0.60A with 8Ah 1.5A with 18Ah 0.26A with 8Ah 0.6A with 18Ah 0.13A with 8Ah 0.3A with 18Ah *See below for quiescent current of PSU under battery when calculating total system standby current resources. Mechanical Product Reference GEN3-08-A GEN3-08-B GEN3-18-B GEN3-08-C GEN3-18-C Enclosure Dimensions w x h x d (mm) 230 x 200 x 80 355 x 330 x 80 330x 275 x 80 Weight (kg) excluding battery 2.0 4.0 3.3 Material 1.2mm steel white powder coated Environmental Temperature Standby Management Maximum Size (Not supplied with unit) Intelligent Recharge Time: Testing: Protection: Quiescent Current: Cold Start (BCS) -10 to +40 C (operating) 75% RH non-condensing -20 to +80 C (storage) Warning: risk of explosion if incorrect battery type fitted GEN3-08: 8 Ah 12V Valve Regulated Lead Acid GEN3-18: 18Ah 12V Valve Regulated Lead Acid < 24 hours to 80% - A heavily discharged battery having a terminal voltage > 9.0V will attempt to be charged. If battery fails to accept charge in 24 hours it will fail the active load test. not Present: <9.0V battery voltage Low battery voltage: <11.6V (no mains present) Active load test at full rated output current Reverse battery connection protection Overvoltage protection - Trips at 125% of rated O/P voltage Deep discharge protection - disconnect at 10.5V battery terminal voltage 64mA when running on battery - less than 1mA after deep discharge protection. Momentarily link BCS pins together to connect battery to load if PSU commissioned without any mains

3 SIGNALLING OUTPUTS Rating: 0.10A @ 60Vdc 16Ω solid state relay contacts, volt free. EPS Fault: Open if Loss of mains for >8s GEN Fault: Open if Output voltage < 9.0V, or Output short circuit, or Output fuse blown APS Fault: Open if terminal voltage < 11.6V, or Active Monitoring detects a failed battery, battery fuse blown or battery not present. Tamper: 0.5A @ 30Vdc volt free contact. Open when lid is open or unit removed from mounting surface. CONNECTIONS O/P +, - EPS (FAULT) GEN (FAULT) BATT +, - APS (FAULT) Connection to equipment to be powered (Observe polarity) Relay output for mains fail. Open if loss of mains. Relay output for General Fault. Open in fault condition Connection to standby battery. Use cables provided (Observe polarity) Relay output for battery fail. Open if battery fail or low voltage INSTALLATION AND COMMISSIONING This unit is only suitable for installation as permanently connected equipment. This PSU is NOT SUITABLE for external installation. EQUIPMENT MUST BE EARTHED. Before installation, ensure that external disconnect device is OFF. The PSU should be installed according to all relevant safety regulations applicable to the application. Min 10cm clearance Load output cable: Current rating to match maximum load FUSED SPUR L E N 3A min Mains Input cable rated: 3A, 300Vac minimum Fasten cables using cable tie Fig 1 Mounting of Power Supply

4 Mounting 1) Site power supply unit allowing minimum clearance see Fig. 1.0 2) Route mains and LV output cables via different knockouts and/or cable entry holes. 3) Use bushes and cable glands rated to UL94 HB minimum. Tamper Assembly 4) Fit combined lid and rear tamper assembly, refer to separate instructions supplied with tamper assembly kit. Lid Fixing Screw (Operates tamper switch) Tamper Assembly (Fixed to wall) Connection block Fig 2 Position of tamper assembly on hinged lid style enclosures Lid Fixing Screw (Operates tamper switch) Connection block Tamper Assembly (Fixed to wall) Fig 3 Position of tamper assembly on clam shell style enclosures 5) Loop tamper cable on clam shell style enclosures and secure with a cable tie as shown in Fig 6 & 7

5 Mains Power Up 6) Attach correctly rated mains cable (minimum 0.5mm 2 [3A], 300/500Vac). Fasten with cable ties. 7) Apply mains power. Check for 13.8V on load outputs. Check green Mains LED is ON. 8) Disconnect mains power. Load Output 9) Loop correctly rated load cable through supplied ferrite (1 turn) and attach to terminal block, note polarity. Fasten with cable ties. Fig 4 Position of ferrite 10) Apply mains power. Check Green Mains LED is ON. NOTE: Red Fault LED may flash to indicate no battery has been connected, this is normal, refer to diagnostic table on page 7. Verify load is operating correctly. 11) Disconnect mains power. Signalling 12) Connect EPS, APS and GEN fault outputs to appropriate inputs of control and indicating equipment (CIE). Standby 13) Attach supplied battery cables to terminal block and batteries. NOTE: ensure correct polarity of battery connections: +ve use Red lead, -ve use Black lead. 14) Position the battery as shown in Figures 5-9 below, avoiding the cover earth connection spades and the cover retaining screws. Adjust battery bracket to hold battery in position. Bracket Fig 5 GEN3-08-A

6 Loop and secure tamper cable with cable tie Loop and secure tamper cable with cable tie Bracket Bracket Fig 6 GEN3-18-B Fig 7 GEN3-08-B Bracket Bracket Fig 8 GEN3-18-C Fig 9 GEN3-08-C 15) Apply mains power. Check that Green Mains LED is ON. Check there is no fault indicated by the Red Fault LED, refer to diagnostic table on page 7. 16) Disconnect mains power. Check that the battery continues to supply voltage and current to the output load. Check that Green Mains LED is OFF and the control panel displays a Loss of Mains (EPS) fault NOTE: The battery must have sufficient charge to supply the output load 17) Reconnect mains power. Check that Green LED is ON. 18) Disconnect battery. Check that Red Fault LED is indicating a fault, refer to diagnostic table on page 7, and that the control panel is showing an APS fault. 19) Reconnect battery. Check there is no fault indicated by the Red Fault LED, refer to diagnostic table on page 7, and that the control panel is not showing an APS fault. 20) Remove Output fuse. Check that Red Fault LED is indicating a fault, refer to diagnostic table on page 7, and that the control panel shows a General PSU fault. 21) Replace Output fuse. Check that Red Fault LED is OFF Check that EPS, APS and GEN Fault signals (if connected) are cleared at the control panel.

Tamper 22) Connect tamper switch to appropriate inputs of control and indicating equipment (CIE). 23) Check that the tamper switch is CLOSED when the lid/cover is closed and the retaining screw is fitted, OPEN when the lid/cover is open. 24) Close the lid and fasten with screw supplied. Alternatively fit the cover in place, the correct orientation is with the cover retaining feature engaging over the bottom lip of the base, fasten with screws supplied. 25) Re-check tamper circuit is closed at control panel. OPERATING INSTRUCTIONS In the event of loss of mains, a battery fault or a GEN fault, the corresponding Fault signal contacts will open. If the output of the PSU fails, the cause of the failure should be investigated e.g. short circuit load, connection of a deeply discharged battery. The fault should be rectified before restoring power to the PSU. If any of the fuses require replacing, ensure the correct fuse rating and type is used. MAINTENANCE Maintenance This unit is intended for use by Service Personnel only. There are NO USER SERVICEABLE parts inside. There is no regular maintenance required of the PSU other than periodic testing, and replacement of the standby battery. Reference should be made to the battery manufacturer's documentation to determine typical/expected battery life with a view to periodic replacement of the battery. DIAGNOSTICS 7 Local Diagnostics Green LED Red LED On = Mains Present Fault Diagnostics according to table: Red LED (fault) Green LED (mains) Status OFF ON Normal: fully charged One short flash every second Flashing: 1second On 1 second Off One short flash every 3 seconds OFF ON ON OFF OFF OFF Normal: charging but not fully charged Fault: Output fuse or battery fuse blown, or battery/psu fault Fault: No mains, output fuse blown Fault: No mains, battery supplying load. Fault: No mains, No output, battery disconnected or completely discharged

8 COMPLIANCE This power supply unit meets the essential requirements of the following EU Directives: EMC: Low Voltage: WEEE: 2004/108/EC 2006/95/EC 2002/96/EC This product is suitable for use in systems designed to comply with PD6662:2010 at Grade 3 and Environmental Class II EN50131-6:2008 Type A Security Grade 3 Environmental Class II Certification Body: Telefication B.V. Edisonstraat 12A Zevenaar, 6902 PK The Netherlands +31 (0) 316-583 180 http://www.telefication.com DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) and 2006/66/EC (). At the end of life, the product must be separated from the domestic waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national and local regulations. Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations. Package used batteries safely for onward transport to your supplier, collection point or disposal facility. Caution: Risk of fire or explosion if bare battery wires are allowed to touch. See Specification for battery type information. The battery is marked with the crossed out wheelie bin symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For more information see: www.recyclethis.info The packaging supplied with this product may be recycled. Please dispose of packaging accordingly.