SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

Similar documents
SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SUNLINE ULTRA SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS 4 AND 5 NOMINAL TON GENERAL FEATURING

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D1HG/D1HE 180 & D-0602

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

TECHNICAL GUIDE DESCRIPTION SERIES 20 SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS J15, 18, 20 & 25 DH JTG-A-1007

DESCRIPTION FEATURES

TECHNICAL GUIDE (R-407C)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108

SINGLE PACKAGE HEAT PUMPS

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

TECHNICAL GUIDE (R-407C)

DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING YTG-B-0807

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

PACKAGE AIR CONDITIONERS

SINGLE PACKAGE COOLING UNITS

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

PHB SERIES 7-1/2 and 10 TON

TECHNICAL GUIDE DESCRIPTION ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU THRU 5 TON (13 SEER) STANDARD FEATURES / BENEFITS

D M S 760 C01 A A 1 1

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON

R-22, 13 SEER 60 Hertz

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON GENERAL FEATURING

PHR5. Product Specifications

TECHNICAL GUIDE 50 HZ

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

TECHNICAL GUIDE 50Hz DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DW-03, -04 & BTG-D-0109

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 180, 210, 240 & YTG-F-1009

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DY 036, 048 & YTG-E-0109

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

PGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DH 036, 048 & YTG-C-0308

RGMA Series Package Gas Electric SPECIFICATIONS

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DL-15, -20 & BTG-F-1109

CHP

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

S/T Ratio. Input BTU/h

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

PRAC14 PRODUCT SPECIFICATIONS

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PCB COMMERCIAL SERIES

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Model 558D/559F Sizes

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS. BP 036 thru 072 HIGH EFFICIENCY YTG-D-0109

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

ZHA/ZHB SERIES WARNING

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

DESCRIPTION SINGLE PACKAGE CONVERTIBLE SERIES HEAT PUMPS FEATURES

PGB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

Transcription:

530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible single packages with a common footprint cabinet and common roof curb for all 7-1/ thru 1-1/ ton sizes. All units have dual compressors with dual independent refrigeration circuits. The units were designed for light commercial applications and can easily be installed on a roof curb, slab, roof jack or frame. All units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way fork lift access and overhead rigging. Every unit is completely charged, wired, piped and tested at the factory to provide for a quick and easy field installation. The units are available in the following configurations: cooling only, cooling with electric heat and cooling with gas heat. Electric heaters are available as field-installed accessories. Both down and side discharge airflows are available without having to swap panels. The installer simply removes the duct covers for the desired configuration. Economizers may be used on either side or down discharge applications with no modifications required. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry an additional 4-year warranty. Aluminized steel tubular heat exchangers carry an additional 9-year warranty. FEATURES COMMON FOOTPRINT / COMMON CABINET - All model sizes and configurations share the exact same footprint cabinet - and therefore the same roof curb. You now have the flexibility of setting one curb and, after the internal load has been determined, placing the proper tonnage unit on that curb. You can even decide between gas or electric heat after the curb has been set. HIGH EFFICIENCY - All units have a minimum EER of 8.5. Gas / electric units have electronic spark ignition and power vented combustion with steady state efficiencies as high as 81.0%. These efficiencies exceed all legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / return is desired you simply remove the two bottom duct covers and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. FACTORY INSTALLED OPTIONS - Economizers,and alternate indoor fan motors can be installed at the factory. The economizers are shipped installed and wired. The outdoor air hood needs only to be field assembled and installed. Field labor dollars can be saved by having the components arrive already installed. FIELD INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in and electrical connections are made by modular plugs. Electric heaters mount easily and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. The 14" high roof curb is shipped knocked down. The roof curb has an insulated deck. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0 F. Propane and high altitude kits are also available to cover all gas heating applications. MOTORIZED AIR DAMPER - Includes slide-in/plug-in damper assembly with rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. Damper is capable of providing 0% thru 100% outdoor return air opening. MANUAL OUTDOOR DAMPER - Provides 0% thru % or 0% thru 100% of return air opening (field adjustable). Designed for duct mounted side or bottom supply/return applications. Includes rain hood assembly and filters WIDE RANGE OF INDOOR AIRFLOWS - All indoor fan motors are belt-drive type providing maximum flexibility to handle most airflow requirements. Factory-installed alternate indoor fan motors are available on some models for high static applications. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. Cont d.

530.18-TGY FEATURES - CONT D. UTILITY CONNECTIONS MADE EASY - Gas and electric utility knockouts are provided in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a low voltage terminal strip. An additional set of pin connectors is also provided so that field interface of external controls will be simplified. A suction line freezestat is supplied on all units to protect against loss of charge and coil frosting due to low economizer outdoor air temperature while the compressors are running. The electrical control box is not located in the compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. AIR FILTERS - Units come standard with " throwaway filters. The unit filter racks can accommodate 1" or " filters without any modifications. SYSTEM PROTECTION - Crankcase heaters and internal compressor protection are standard on all compressors. Every unit has liquid line filter-driers, high pressure switches and suction line freezestats to protect all system components. The units will operate down to 45 F without any additional low ambient controls. SUNLINE 000 MODEL DCG 10 TON (Gas Heating) TABLE OF CONTENTS Description...1 Features...1 Ratings...3 Physical Data...3 Cooling Capacities...4 Blower Performance...8 Blower Motor and Drive Data...1 Accessory Static Resistances...1 Component Weights... 1 Field Wiring... 13 Electrical Data - Basic Units... 13 Electrical Data - Cooling / Electric Heating... 14 & 15 Options and Accessories...16 Unit Dimensions...17 Roof Curb Dimensions...19 Typical Applications... 0 Unitary Products Group

RATINGS CAPACITY RATINGS - Cooling / Electric Heating MODEL ARI RATINGS COOLING CAPACITY 80 / 67-95 F MBH EER IPLV Std. SOUND RATING (dbels) NOMINAL ELECTRIC HEAT CAPACITY (KW) D4CE090 87 9.00 9. 3,000 90 9, 18, 4, 36 D3CE10 10 9.00 9.50 3,400 90 9, 18, 4, 36 D4CE10 117 9.50 10.0 4,000 90 18, 4, 36, 54 D4CE150 14 8.50 8.30 4,0-18, 4, 36, 54 530.18-TGY 08/30, 575V MODELS ONLY 7-1/ 10 TON 1-1/ TON 08/30, 4V MODELS ONLY CAPACITY RATINGS - Cooling / Gas Heating MODEL D4CG090N130 D4CG090N165 D3CG10N130 D3CG10N165 D4CG10N165 D4CG10N00 D4CG150N165 D4CG150N00 ARI RATINGS COOLING CAPACITY SOUND 80 / 67-95 F RATING MBH EER IPLV Std. (dbels) 87 9.00 9. 87 9.00 9. 3,000 90 10 9.00 9.50 10 9.00 9.50 3,400 90 117 9.50 10.0 117 9.50 10.0 4,000 90 14 8.50 8.30 14 8.50 8.30 4,0 - NOTES: 1. All gas units are two-stage heating. First stage is % of total.. All 090-10 units are rated in accordance with ARI Standard 10. 3. All 150 units are rated in accordance with ARI Standard 3. 4. Sound ratings are in accordance with ARI Standard. 5. Heaters available as accessories - all with single point power supply. 6. EER = Energy Efficiency Ratio - the cooling capacity in BTU s per hour (BTUH) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). 7. S.S.E. = Steady State Efficiency. (Percent Output). 8 I.P.L.V. = Integrated Part Load Value INPUT (MBH) 163 04 163 04 04 45 04 45 OUTPUT (MBH) 130 163 130 163 163 198 163 198 GAS HEAT CAPACITY S.S.E. (%) 80.0 80.0 80.0 80.0 80.0 81.0 80.0 80.6 TEMP. RISE ( F) 30-30 - 30-30 - 30-30 - 30-30 - GAS LINE SIZE (in. OD) 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 INDOOR SOUND POWER RATINGS Unit Size 090 10 10 150 3,000 3,400 4,000 5,000 ESP Blower Sound Power (db 10-1 Watts) Octave Band Centerline Frequency (Hz) IWG RPM BHP 63 15 50 500 1,000,000 4,000 8,000 0.80 0.65 0.80 0.80 1,145 1,15 9 1,100 1.85..0.0 9 94 94 98 9 94 94 98 8 84 84 88 *At a distance of 10 ft.from the blower. NOTE: These values have been derived using a model of sound propagation, measuring the indoor ambient sound levels ten feet from the source. The dba values provided are for reference only. Calculation of dba values cover matters of system design and application. This constitutes an exception to any specification or guarantee requiring a dba value or sound data in any other form than sound power level ratings. 75 77 77 81 77 79 79 83 7 7 76 65 67 67 71 6 6 66 SWL db(a) 8 84 84 88 db(a) @ 10 Ft* 49 51 51 55 Unitary Products Group 3

530.18-TGY PHYSICAL DATA BASIC UNITS EVAPORATOR EVAPORATOR COIL CONDENSER FAN (Two Per Unit) CONDENSER COIL AIR FILTERS (SEE NOTE) CHARGE COMPRESSOR QTY./TYPE MODELS DCE DCG 090 10 10 150 090 10 10 150 CENTRIFUGAL (Dia. x Wd. in.) 1 x 1 15 x 1 1 x 1 15 x 1 FAN MOTOR HP (STANDARD) 1 1 3 3 FAN MOTOR HP (ALTERNATE) 3 3 5-3 3 5 ROWS DEEP 4 4 4 4 FINS PER INCH 15 15 15 15 FACE AREA (Sq. Ft.) 7.8 9.1 10.9 13.4 7.8 9.1 10.9 13.4 PROPELLER DIA. (in.) (Each) 4 4 4 4 FAN MOTOR HP (Each) 1 1 1 3 4 1 1 1 3 4 NOM. TOTAL (Each) 900 300 30 4400 900 300 30 4400 ROWS DEEP FINS PER INCH 13 13 13 13 FACE AREA (Sq. Ft.) 16.7 0.0 4.0 9.3 16.7 0.0 4.0 9.3 QUANTITY PER UNIT (1" x 4" x ") - - - - QUANTITY PER UNIT (16" X 4" X ") 3 3 QUANTITY PER UNIT (18" X 4" X ") - - - - TOTAL FACE AREA (sq. ft.) 9.3 9.3 11.3 14.0 9.3 9.3 11.3 14.0 REFRIGERANT- SYSTEM NO. 1 6/8 7/4 8/0* 10/4 6/8 7/4 8/0* 10/4 (lbs./oz.) SYSTEM NO. 6/8 7/11 8/0 10/8 6/8 7/11 8/0 10/8 HERMETIC SCROLL RECIP SCROLL RECIP SCROLL RECIP SCROLL RECIP NOTE: Filter racks are adapted for 1" or " thick filters.. ELECTRICAL DATA - Basic Units MODEL DCE090 DCG090 DCE10 DCG10 DCE10 DCG10 DCE150 DCG150 POWER SUPPLY 08/30-3- 4-3- 575-3- 08/30-3- 4-3- 575-3- 08/30-3- 4-3- 575-3- 08/30-3- 4-3- 575-3- COMPRESSOR (#1 and #) 1 RLA EACH 13.1 6.7 5.8 16.0 8.3 7.1 17. 8.5 6.4 1.8 9.6 9.0 LRA EACH 90 45 36 137 69 58 15 67 50 158 79 65 OUTDOOR FAN MOTOR, (#1 & #) FLA EACH.3 1.3 1.3.3 1.3 1.3.3 1.3 1.3 3.5.5.5 SUPPLY AIR MOTOR, FLA TOTAL UNIT AMPACITY, AMPS 1.5HP HP 3HP 5HP 1.5HP HP 3HP 5HP 5.7.6.1 NOTES: 1. Dual numbers shown as 8./17.3" amps indicates compressor #1 / # respectively.. Dual element, time delay type. Amps shown as 90/100" indicates rating for LO HP / HI HP respectively. Maximum HACR breaker of the same AMP size is applicable, except 575 volt units. 7.5 3.4.7 7.5 3.4.7 7.5 3.4.7 10.6 4.8 3.9 10.6 4.8 3.9 10.6 4.8 3.9 15.1 7.5 5.9 39.8 0.3 17.8 41.6 1.1 18.4 48. 4.8 1. 50.8 5.1 19.7 51.3 6..4 53.9 6.5 0.9 66.6 31.4 9.1 71.1 34.1 31.1 MAX. FUSE SIZE AMPS 50 5 0 30 5 / 30/ 5 80/90 40 /40 VOLTAGE LIMITATIONS* POWER SUPPLY VOLTAGE MIN. MAX. 08/30-3- 187 53 4-3- 414 506 575-3- 518 630 4 Unitary Products Group

530.18-TGY COOLING CAPACITIES - 7-1/ TON (DCE / DCG090) Air On Evaporator Coil 3750 3375 3000 65 50 Temperature of Air on Condenser Coil 85 F 95 F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 104 7.4 79 68 58 48 38 - - 103 8. 79 69 59 49 39 - - 67 97 7.3 97 87 77 66 56 46 36 93 8.1 93 86 76 66 56 46 36 6 90 7.3 90 90 90 80 50 86 8.1 86 86 86 76 66 56 46 57 87 7.3 87 87 87 77 67 57 47 85 8.1 85 85 85 75 65 55 45 WB F 7 103 7.4 74 65 56 46 37 - - 101 8.1 74 65 56 46 37 - - 67 96 7.3 91 8 73 64 54 45 36 91 8.1 89 81 7 6 53 44 6 89 7.3 89 89 87 78 69 51 84 8.0 84 84 84 74 65 56 47 57 86 7. 86 86 86 76 67 58 49 83 8.0 83 83 83 73 64 55 46 7 10 7.3 69 61 53 44 36 - - 99 8.1 69 61 5 44 36 - - 67 95 7.3 86 77 69 61 5 44 36 90 8.0 84 76 67 59 51 43 34 6 88 7. 88 88 85 76 68 5 83 8.0 83 83 81 73 65 56 48 57 86 7. 86 86 84 76 67 59 51 8 8.0 8 8 80 7 64 56 47 7 99 7.3 64 57 49 4 - - 97 8.1 63 56 49 41 34 - - 67 9 7. 79 7 65 57 50 43 88 8.0 77 63 55 48 41 33 6 86 7. 86 84 79 7 65 57 50 81 8.0 81 79 75 68 61 54 46 57 83 7. 83 83 79 71 64 57 49 80 8.0 80 79 75 67 53 45 7 96 7.3 59 53 46 40 33 - - 94 8.1 58 51 45 39 3 - - 67 89 7. 73 67 54 48 41 85 8.1 71 64 58 51 45 39 3 6 83 7. 83 80 74 68 61 55 49 79 8.0 79 76 63 57 51 44 57 81 7.1 81 80 73 67 61 54 48 78 8.1 78 75 69 6 56 50 43 Air On Evaporator Coil 3750 3375 3000 65 50 Temperature of Air on Condenser Coil 105 F 115 F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 98 9.1 77 67 57 47 37 - - 93 10.0 75 65 55 45 - - 67 88 9.0 88 84 74 64 53 43 33 83 9.8 83 81 71 61 51 41 31 6 81 8.9 81 81 81 71 61 51 41 76 9.6 76 76 76 66 56 46 36 57 80 9.0 80 80 80 50 40 75 9.8 75 75 75 65 55 45 WB F 7 96 9.1 7 63 54 44 - - 91 10.0 61 5 4 33 - - 67 86 9.0 85 78 69 51 4 33 81 9.8 81 76 67 58 49 39 30 6 79 8.8 79 79 79 51 4 74 9.6 74 74 74 65 56 46 37 57 79 8.9 79 79 78 68 59 50 41 74 9.8 74 74 73 64 54 45 36 7 94 9.0 67 59 50 4 34 - - 90 10.0 65 56 48 40 3 - - 67 85 8.9 8 73 65 57 48 40 3 79 9.8 79 71 6 54 46 38 9 6 78 8.8 78 78 77 68 5 43 73 9.6 73 73 7 64 55 47 39 57 77 8.9 77 77 75 67 59 50 4 7 9.8 7 7 6 54 45 37 7 91 9.0 61 54 47 39 3 - - 86 10.0 59 5 44 37 30 - - 67 8 8.9 75 67 53 46 38 31 77 9.8 7 65 58 50 43 36 8 6 75 8.8 75 75 71 64 56 49 4 9.6 65 59 5 44 37 57 75 8.9 75 74 6 55 48 40 69 9.8 69 69 65 58 50 43 36 7 89 9.1 55 49 43 36 30 - - 83 10.0 53 47 41 34 8 - - 67 79 9.0 68 6 55 49 43 36 30 74 9.8 66 59 53 47 40 34 7 6 73 8.8 73 7 65 59 53 46 40 68 9.6 68 67 61 55 48 4 57 7 8.9 7 71 64 58 51 45 39 67 9.8 67 66 59 53 47 40 34 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.415 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total 1 KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 5

530.18-TGY COOLING CAPACITIES - 8-1/ TON (DCE / DCG 10) Air On Evaporator Coil 450 385 3400 975 550 Temperature of Air on Condenser Coil 85 F 95 F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 133 9. 96 83 57 - - - 130 9.8 97 84 71 59 - - - 67 10 9.0 116 103 91 78 65 5-119 9.5 119 107 95 8 69 56-6 110 8.8 110 110 110 97 85 7 59 104 9.3 104 104 104 91 79 66 53 57 109 8.8 109 109 109 96 83 58 99 9.3 99 99 99 86 74 61 48 WB F 7 130 9.1 89 78 66 55 - - - 15 9.8 89 77 66 54 - - - 67 119 8.9 110 98 87 75 64 53-116 9.5 110 99 88 77 65 54-6 108 8.7 108 108 105 93 8 71 59 100 9.3 100 100 99 87 76 65 53 57 106 8.7 106 106 105 94 8 71 59 95 9.3 95 95 94 83 71 49 7 17 9.1 83 73 63 53 - - - 10 9.8 80 50 - - - 67 118 8.8 103 93 83 73 63 53-113 9.5 10 9 81 71 61 51-6 105 8.6 105 105 100 90 79 69 59 96 9. 96 96 94 83 73 63 53 57 104 8.6 104 104 10 91 81 71 61 9 9. 9 9 89 79 69 59 49 7 13 9.0 76 67 58 49 - - - 116 9.7 74 65 56 47 - - - 67 113 8.8 94 85 76 67 58 49-107 9.4 93 84 75 66 57 48-6 10 8.6 10 100 93 84 75 66 57 93 9. 93 9 87 78 69 51 57 100 8.6 100 100 95 86 77 68 59 88 9. 88 88 83 74 65 56 47 7 119 9.0 6 54 46 - - - 11 9.6 67 5 44 - - - 67 108 8.7 86 78 6 54 46-10 9.4 84 76 68 61 53 45-6 99 8.6 99 94 86 78 6 55 89 9.1 89 88 81 73 65 57 49 57 97 8.5 97 96 88 80 7 64 56 85 9.1 85 85 77 69 61 53 46 Air On Temperature of Air on Condenser Coil Evaporator 105 F 115 F Coil Total Power Sensible Capacity 1, MBH Total Power Sensible Capacity 1, MBH WB Cap. 1 Input Entering Dry Bulb, F Cap. 1 Input Entering Dry Bulb, F F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 117 10.5 90 78 65 5 - - - 104 11.1 84 71 59 46 - - - 450 67 106 10.1 106 100 88 75 6 49-93 10.7 93 93 81 68 55 4-6 97 9.9 97 97 97 84 71 59 46 90 10.5 90 90 90 77 64 5 39 57 90 9.9 90 90 90 77 65 5 39 81 10.5 81 81 81 68 56 43 30 7 115 10.4 84 73 61 50 - - - 105 11.0 79 68 57 45 - - - 385 67 105 10.1 103 95 84 7 61 49-95 10.6 95 90 79 68 56 45-6 95 9.8 95 95 94 83 71 49 90 10.4 90 90 89 78 67 55 44 57 89 9.8 89 89 87 76 65 53 4 8 10.4 8 8 81 69 58 46 7 113 10.3 78 68 57 47 - - - 106 10.9 75 65 55 45 - - - 3400 67 105 10.0 99 90 79 69 59 49-97 10.5 97 87 77 67 57 47-6 94 9.8 94 94 9 81 71 61 51 91 10.4 91 91 90 79 69 59 49 57 87 9.8 87 87 85 75 65 55 44 8 10.3 8 8 80 50 40 7 108 10.3 71 6 53 44 - - - 99 10.8 67 58 49 40 - - - 975 67 99 9.9 90 81 7 63 54 45-90 10.5 86 78 69 51 4-6 89 9.7 89 89 84 75 66 57 48 86 10.3 86 85 81 7 63 54 45 57 83 9.7 83 83 78 69 51 4 77 10.3 77 77 7 63 54 45 36 7 10 10. 63 56 48 40 - - - 93 10.8 59 5 44 36 - - - 550 67 9 9.9 80 7 64 56 49 41-83 10.4 76 68 5 45 37-6 85 9.6 85 84 76 68 5 45 80 10. 80 79 7 64 56 48 40 57 79 9.6 79 79 71 63 55 47 39 7 10. 7 7 64 56 48 41 33 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.415 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total 1 KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY 6 Unitary Products Group

530.18-TGY COOLING CAPACITIES - 10 TON (DCE / DCG10) Air On Temperature of Air on Condenser Coil Evaporator 85 F 95 F Coil Total Power Sensible Capacity 1, MBH Total Power Sensible Capacity 1, MBH WB Cap. 1 Input Entering Dry Bulb, F Cap. 1 Input Entering Dry Bulb, F F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 139 9.6 106 9 79 65 5 - - 1 10.6 105 9 78 64 51 - - 5000 67 131 9.4 130 117 103 90 76 63 49 17 10.4 17 116 10 89 75 6 48 6 11 9.4 11 11 11 107 94 80 67 117 10.4 117 117 117 104 90 77 63 57 119 9.5 119 119 119 106 9 79 65 116 10.4 116 116 116 10 89 75 6 7 137 9.5 101 88 76 63 51 - - 133 10.5 99 87 74 6 49 - - 4500 67 130 9.3 14 11 99 87 74 6 50 15 10. 11 110 97 85 7 47 6 119 9.3 119 119 117 104 9 80 67 115 10.3 115 115 115 10 90 77 65 57 118 9.4 118 118 118 106 93 81 68 114 10.3 114 114 114 101 89 77 64 7 136 9.4 95 84 73 61 50 - - 131 10.4 93 8 59 48 - - 4000 67 18 9.1 118 107 95 84 73 61 50 13 10.1 115 103 9 81 69 58 47 6 118 9. 118 118 113 10 90 79 68 113 10. 113 113 11 101 90 78 67 57 117 9.3 117 117 117 105 94 83 71 11 10. 11 11 11 100 89 78 66 7 131 9.4 88 78 67 57 47 - - 16 10.4 85 75 63 55 45 - - 00 67 14 9. 108 98 88 78 68 58 48 119 10. 105 95 85 75 65 55 45 6 114 9. 114 11 105 95 85 75 65 109 10. 109 109 104 94 84 74 64 57 113 9.3 113 113 108 98 88 78 68 108 10. 108 108 103 93 83 73 63 7 17 9.5 80 71 6 53 45 - - 11 10.5 77 69 51 4 - - 3000 67 10 9.3 99 90 81 73 64 55 46 114 10. 96 87 78 69 61 5 43 6 110 9.3 110 105 97 88 79 61 105 10.3 105 104 95 87 78 69 57 109 9.4 109 109 100 91 8 73 65 104 10.3 104 104 95 86 77 69 Air On Temperature of Air on Condenser Coil Evaporator 105 F 115 F Coil Total Power Sensible Capacity 1, MBH Total Power Sensible Capacity 1, MBH WB Cap. 1 Input Entering Dry Bulb, F Cap. 1 Input Entering Dry Bulb, F F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 18 11.7 103 89 76 6 49 - - 1 1.9 101 87 74 46 - - 5000 67 119 11.5 119 113 99 86 7 59 45 110 1.7 110 110 96 83 69 56 4 6 110 11.5 110 110 110 96 83 69 55 10 1.6 10 10 10 88 75 61 48 57 109 11.6 109 109 109 95 8 68 55 10 1.7 10 10 10 88 75 61 48 7 16 11.6 97 84 7 59 47 - - 10 1.8 94 8 69 57 44 - - 4500 67 117 11.5 114 106 94 81 69 57 44 108 1.7 108 103 91 78 66 53 41 6 108 11.4 108 108 108 95 83 58 100 1.6 100 100 100 88 75 63 51 57 107 11.5 107 107 107 95 8 57 100 1.7 100 100 100 88 75 63 50 7 14 11.6 90 79 68 56 45 - - 118 1.8 88 76 65 54 4 - - 4000 67 115 11.4 110 100 89 77 66 55 43 106 1.6 106 96 85 74 6 51 40 6 106 11.3 106 106 105 94 83 71 99 1.5 99 99 99 87 76 65 53 57 105 11.4 105 105 105 94 8 71 99 1.6 99 99 98 87 76 64 53 7 10 11.6 83 7 6 5 4 - - 114 1.7 80 50 40 - - 00 67 111 11.4 101 9 8 7 6 51 41 10 1.6 98 88 78 68 58 48 38 6 10 11.4 10 10 97 87 77 67 57 95 1.5 95 95 91 81 71 50 57 10 11.4 10 101 97 87 77 67 57 95 1.6 95 95 91 80 50 7 115 11.6 75 66 57 48 39 - - 109 1.7 7 63 55 46 37 - - 3000 67 106 11.4 9 84 75 66 57 48 40 98 1.6 89 80 71 63 54 45 36 6 98 11.4 98 98 89 80 71 63 54 9 1.5 9 9 83 74 65 56 47 57 98 11.4 98 98 89 80 71 6 54 9 1.6 9 91 83 74 65 56 47 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.415 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total 1 KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 7

530.18-TGY COOLING CAPACITIES - 1-1/ TON (DCE / DCG 150) Air On Evaporator Coil 5500 550 5000 4375 3750 Temperature of Air on Condenser Coil 85 F 95 F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 171 1.9 10 105 88 73 - - - 169 14.0 117 10 85 - - - 67 157 1.7 148 13 116 100 84 68-15 13.6 146 131 114 99 83 67-6 145 1.4 145 145 145 19 113 98 8 140 13.3 140 140 140 14 108 9 77 57 145 1.4 145 145 145 130 114 98 83 140 13.3 140 140 140 17 110 95 79 WB F Air On Evaporator Coil 5500 550 5000 4375 3750 7 169 1.9 116 101 85 71 - - - 165 14.0 113 99 84 68 - - - 67 157 1.7 144 19 114 99 84 69-151 13.6 143 19 113 98 84 68-6 143 1.4 143 143 141 16 110 96 81 137 13. 137 137 137 1 107 9 77 57 143 1.4 143 143 143 19 113 98 84 137 13. 137 137 137 15 109 94 80 7 167 13.0 11 98 84 69 - - - 16 14.0 110 96 8 67 - - - 67 157 1.7 140 16 111 98 84 69-151 13.6 140 17 11 98 84 69-6 14 1.4 14 14 136 1 108 93 80 1 13. 1 1 134 10 106 91 77 57 14 1.4 14 14 141 17 11 99 84 1 13. 1 1 1 13 108 94 80 7 16 1.9 104 91 78 65 - - - 157 13.9 101 88 75 6 - - - 67 151 1.7 19 116 104 91 78 65-144 13.5 18 115 10 89 77 64-6 137 1.3 137 136 18 115 103 90 77 131 13.1 131 130 14 111 98 85 73 57 137 1.3 137 137 13 10 108 94 8 131 13.1 131 131 16 113 101 88 76 7 156 1.8 95 84 73 61 - - - 15 13.8 91 80 69 58 - - - 67 144 1.6 117 107 95 84 73 6-137 13.4 114 103 9 81 59-6 13 1.3 13 131 119 108 97 86 75 16 13.1 16 14 113 10 91 80 69 57 13 1. 13 13 14 11 10 90 80 16 13.1 16 16 115 105 93 83 71 Temperature of Air on Condenser Coil 105 F 115 F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F Total Cap. 1 Power Input Sensible Capacity 1, MBH Entering Dry Bulb, F MBH KW 86 83 80 77 74 71 68 MBH KW 86 83 80 77 74 71 68 7 1 14.9 116 100 84 68 - - - 15 15.9 115 99 84 67 - - - 67 138 14.4 1 17 111 95 80 63-15 15. 15 13 108 91 76-6 18 14.0 18 18 18 111 96 81 64 115 14.8 115 115 115 100 84 68 5 57 18 14.0 18 18 18 117 101 85 69 115 14.8 115 115 115 108 91 76 WB F 7 156 14.9 111 97 8 66 - - - 148 15.8 109 95 80 64 - - - 67 137 14.3 133 14 108 94 79 63-13 15. 13 119 105 89 74-6 15 14.0 15 15 15 109 95 80 64 11 14.7 11 11 11 97 83 67 5 57 15 14.0 15 15 15 114 99 84 69 11 14.7 11 11 11 104 88 74 59 7 154 14.8 108 93 79 64 - - - 144 15.8 105 90 76 6 - - - 67 136 14.3 131 11 107 9 78 63-11 15.0 11 115 101 86 7 58-6 1 14.0 1 1 11 108 93 79 64 109 14.7 109 109 108 95 81 66 5 57 1 14.0 1 1 1 111 97 83 68 109 14.7 109 109 109 100 86 7 58 7 149 14.7 98 85 73 - - - 140 15.7 96 84 58 - - - 67 130 14. 11 109 97 84 7-116 14.9 113 105 9 80 67 54-6 118 13.9 118 118 11 100 87 74 61 107 14.6 107 107 101 88 76 63 50 57 118 13.9 118 118 116 104 90 78 65 107 14.6 107 107 106 93 91 68 55 7 144 14.6 89 78 67 56 - - - 1 15.6 87 76 64 54 - - - 67 14 14.1 110 99 87 77 65 55-111 14.8 106 95 84 7 61 50-6 114 13.8 114 113 103 9 81 59 103 14.5 103 10 93 8 71 49 57 114 13.8 114 114 107 95 84 73 6 103 14.5 103 103 97 86 75 64 53 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor, MBH = 3.415 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor. These ratings include the condenser fan motors (Total 1.3 KW) and the compressor motors but not the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY 8 Unitary Products Group

PERFORMANCE - (7-1/ TON SUPPLY AIR) 530.18-TGY MODEL DCE090 - (SIDE DUCT APPLICATIONS) 50 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.93 1.16 1.08 0.79 1.7 1.18 0.53 1.45 1. 0.9 1.65 1.54 - - - 105 1.08 1.1 1.13 0.95 1.34 1.5 0.68 1.54 1.44 0.4 1.75 1.63 0.17 1.97 1.84 10 1. 1.3 1.3 1.08 1.46 1.36 0.83 1.68 1.57 0.58 1.89 1.76 0.3.11 1.97 1130 1.41 1.43 1.33 1.9 1.57 1.46 1.0 1.83 1.71 0.77.04 1.90 - - - 1175 1.61 1.51 1.41 1.49 1.67 1.56 1.3 1.9 1.79 0.96.18.03 - - - 10 1.78 1.66 1.55 1.66 1.81 1.69 1.39.10 1.96 - - - - - - MODEL DCE090 - (BOTTOM DUCT APPLICATIONS) 50 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.86 1.16 1.08 0. 1.7 1.18 0.40 1.45 1. 0.1 1.65 1.54 - - - 105 1.01 1.1 1.13 0.86 1.34 1.5 0.55 1.54 1.44 0.5 1.75 1.63 - - - 10 1.15 1.3 1.3 0.99 1.46 1.36 0. 1.68 1.57 0.41 1.89 1.76 0.1.11 1.97 1130 1.34 1.43 1.33 1.0 1.57 1.46 0.89 1.83 1.71 0..04 1.90 - - - 1175 1.54 1.51 1.41 1.40 1.67 1.56 1.10 1.9 1.79 0.79.18.03 - - - 10 1.71 1.66 1.55 1.57 1.81 1.69 1.6.10 1.96 - - - - - - MODEL DCG090 - (SIDE DUCT APPLICATIONS) 50 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.83 1.16 1.08 0.66 1.7 1.18 0.37 1.45 1. 0.08 1.65 1.54 - - - 105 0.98 1.1 1.13 0.8 1.34 1.5 0.5 1.54 1.44 0.1 1.75 1.63 - - - 10 1.1 1.3 1.3 0.95 1.46 1.36 0.67 1.68 1.57 0.37 1.89 1.76 0.07.11 1.97 1130 1.31 1.43 1.33 1.16 1.57 1.46 0.86 1.83 1.71 0.56.04 1.90 - - - 1175 1.51 1.51 1.41 1.36 1.67 1.56 1.07 1.9 1.79 0.75.18.03 - - - 10 1.68 1.66 1.55 1.53 1.81 1.69 1.3.10 1.96 - - - - - - MODEL DCG090 - (BOTTOM DUCT APPLICATIONS) 50 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.76 1.16 1.08 0.57 1.7 1.18 0.4 1.45 1. - - - - - - 105 0.91 1.1 1.13 0.73 1.34 1.5 0.39 1.54 1.44 0.04 1.75 1.63 - - - 10 1.05 1.3 1.3 0.86 1.46 1.36 0.54 1.68 1.57 0.0 1.89 1.76 - - - 1130 1.4 1.43 1.33 1.07 1.57 1.46 0.73 1.83 1.71 0.39.04 1.90 - - - 1175 1.44 1.51 1.41 1.7 1.67 1.56 0.94 1.9 1.79 0.58.18.03 - - - 10 1.61 1.66 1.55 1.44 1.81 1.69 1.10.10 1.96 - - - - - - NOTES: 1. Blower performance includes a wet evaporator coil and " filters.. For DCG units, blower performance includes the maximum number of heat exchangers. 3. Refer to the Accessory Static Resistances table. ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower. 4. DCE models include a baffle to direct the proper flow of air across our electric heaters. On cooling only applications, this baffle MUST be removed to get the ESP values listed in the above tables. = Larger Horsepower Alternate Motor Required. Unitary Products Group 9

530.18-TGY PERFORMANCE - (8-1/ TON SUPPLY AIR) MODEL DCE10 - (SIDE DUCT APPLICATIONS) 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.79 1.7 1.18 0.53 1.45 1. 0.9 1.65 1.54 0.08 1.6 1.4 105 0.95 1.34 1.5 0.68 1.54 1.44 0.4 1.75 1.63 0.17 1.97 1.84 10 1.08 1.46 1.36 0.83 1.68 1.57 0.58 1.89 1.76 0.3.11 1.97 1130 1.9 1.57 1.46 1.0 1.83 1.71 0.77.04 1.90 0.5..06 1175 1.49 1.67 1.56 1.3 1.9 1.79 0.96.18.03 0.7.34.16 10 1.66 1.81 1.69 1.39.10 1.96 1.0.37.15 0.95.78.56 MODEL DCE10 - (BOTTOM DUCT APPLICATIONS) 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0. 1.7 1.18 0.40 1.45 1. 0.1 1.65 1.54 - - - 105 0.86 1.34 1.5 0.55 1.54 1.44 0.5 1.75 1.63 - - - 10 0.99 1.46 1.36 0. 1.68 1.57 0.41 1.89 1.76 0.1.11 1.97 1130 1.0 1.57 1.46 0.89 1.83 1.71 0..04 1.90 0.4..06 1175 1.40 1.67 1.56 1.10 1.9 1.79 0.79.18.03 0.4.34.16 10 1.57 1.81 1.69 1.6.10 1.96 0.91.37.15 0.58.78.56 MODEL DCG10 - (SIDE DUCT APPLICATIONS) 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.66 1.7 1.18 0.37 1.45 1. 0.08 1.65 1.54 - - - 105 0.8 1.34 1.5 0.5 1.54 1.44 0.1 1.75 1.63 - - - 10 0.95 1.46 1.36 0.67 1.68 1.57 0.37 1.89 1.76 0.07.11 1.97 1130 1.16 1.57 1.46 0.86 1.83 1.71 0.56.04 1.90 0.16..06 1175 1.36 1.67 1.56 1.07 1.9 1.79 0.75.18.03 0.31.34.16 10 1.53 1.81 1.69 1.3.10 1.96 0.86.37.15 0.48.78.56 MODEL DCG10 - (BOTTOM DUCT APPLICATIONS) 550 3000 3400 3750 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 975 0.57 1.7 1.18 0.4 1.45 1. - - - - - - 105 0.73 1.34 1.5 0.39 1.54 1.44 0.04 1.75 1.63 - - - 10 0.86 1.46 1.36 0.54 1.68 1.57 0.0 1.89 1.76 0.04.11 1.97 1130 1.07 1.57 1.46 0.73 1.83 1.71 0.39.04 1.90 0.13..06 1175 1.7 1.67 1.56 0.94 1.9 1.79 0.58.18.03 0.8.34.16 10 1.44 1.81 1.69 1.10.10 1.96 0.66.37.15 0.36.78.56 NOTES: 1. Blower performance includes a wet evaporator coil and " filters.. For DCG units, blower performance includes the maximum number of heat exchangers. 3. Refer to the Accessory Static Resistances table. ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower. 4. DCE models include a baffle to direct the proper flow of air across our electric heaters. On cooling only applications, this baffle MUST be removed to get the ESP values listed in the above tables. = Larger Horsepower Alternate Motor Required. 10 Unitary Products Group

PERFORMANCE - (10 TON SUPPLY AIR) 530.18-TGY MODEL DCE10 - (SIDE DUCT APPLICATIONS) 3000 00 4000 4500 5000 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 8 1.14 1.40 1.31 0.98 1.58 1.48 0.77 1.80 1.68 0.53.05 1.91 0.5.31.15 915 1.3 1.55 1.45 1.18 1.76 1.64 0.95 1.98 1.85 0.7.3.08 0.49.48.31 950 1.51 1.68 1.57 1.37 1.91 1.78 1.15.14.00 0.91.43.7 0.67.7.54 1000 1.69 1.83 1.71 1.57.07 1.93 1..33.17 1.14.6.45 0.9.91.7 1050 1.89 1.98 1.84 1.78.5.10 1.57.55.37 1..86.67 1.1 3.17.96 1090.08.1 1.97 1.97.41.4 1.78.7.54 1.55 3.06.86 - - - MODEL DCE10 - (BOTTOM DUCT APPLICATIONS) 3000 00 4000 4500 5000 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 8 1.01 1.40 1.31 0.80 1.58 1.48 0.54 1.80 1.68 0.3.05 1.91 - - - 915 1.19 1.55 1.45 1.00 1.76 1.64 0.7 1.98 1.85 0.4.3.08 0.13.48.31 950 1.38 1.68 1.57 1.19 1.91 1.78 0.9.14.00 0.61.43.7 0.31.7.54 1000 1.56 1.83 1.71 1.39.07 1.93 1.1.33.17 0.84.6.45 0.56.91.7 1050 1.76 1.98 1.84 1..5.10 1.34.55.37 1.05.86.67 0.76 3.17.96 1090 1.95.1 1.97 1.79.41.4 1.55.7.54 1.5 3.06.86 - - - MODEL DCG10 - (SIDE DUCT APPLICATIONS) 3000 00 4000 4500 5000 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 8 1.05 1.40 1.31 0.85 1.58 1.48 0.6 1.80 1.68 0.3.05 1.91 - - - 915 1.3 1.55 1.45 1.05 1.76 1.64 0.80 1.98 1.85 0.51.3.08 0..48.31 950 1.4 1.68 1.57 1.4 1.91 1.78 1.00.14.00 0..43.7 0.40.7.54 1000 1. 1.83 1.71 1.44.07 1.93 1.0.33.17 0.93.6.45 0.65.91.7 1050 1.80 1.98 1.84 1.65.5.10 1.4.55.37 1.14.86.67 0.85 3.17.96 1090 1.99.1 1.97 1.84.41.4 1.63.7.54 1.34 3.06.86 - - - MODEL DCG10 - (BOTTOM DUCT APPLICATIONS) 3000 00 4000 4500 5000 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 8 0.9 1.40 1.31 0.67 1.58 1.48 0.39 1.80 1.68 0.0.05 1.91 - - - 915 1.10 1.55 1.45 0.87 1.76 1.64 0.57 1.98 1.85 0.1.3.08 - - - 950 1.9 1.68 1.57 1.06 1.91 1.78 0.77.14.00 0.40.43.7 0.04.7.54 1000 1.47 1.83 1.71 1.6.07 1.93 0.97.33.17 0.63.6.45 0.9.91.7 1050 1.67 1.98 1.84 1.47.5.10 1.19.55.37 0.84.86.67 0.49 3.17.96 1090 1.86.1 1.97 1.66.41.4 1.40.7.54 1.04 3.06.86 - - - NOTES: 1. Blower performance includes a wet evaporator coil and " filters.. For DCG units, blower performance includes the maximum number of heat exchangers. 3. Refer to the Accessory Static Resistances table. ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower. 4. DCE models include a baffle to direct the proper flow of air across our electric heaters. On cooling only applications, this baffle MUST be removed to get the ESP values listed in the above tables. = Larger Horsepower Alternate Motor Required. Unitary Products Group 11

530.18-TGY PERFORMANCE - (1-1/ TON SUPPLY AIR) MODEL DCE150 - (SIDE DUCT APPLICATIONS) 4000 4500 5000 5500 00 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 9 1.15.14.00 0.91.43.7 0.67.7.54 0.38 3.03.83 0.8 3.94 3.67 1000 1..33.17 1.14.6.45 0.9.91.7 0.6 3.4 3.03 0.46 4.0 3.91 1050 1.57.55.37 1..86.67 1.1 3.17.96 0.89 4.06 3.79 0.69 4.53 4. 1090 1.78.7.54 1.55 3.06.86 1.37 3.78 3.53 1.05 4.8 3.99 0.88 4.79 4.46 1105 1.89 3.08.87 1.68 3.45 3. 1.45 3.88 3.6 1.1 4. 4.06 0.96 4.89 4.56 1140.06 3.5 3.03 1.84 3.66 3.41 1.6 4.11 3.83 1.9 4.53 4. 1.15 5.1 4.77 MODEL DCE150 - (BOTTOM DUCT APPLICATIONS) 4000 4500 5000 5500 00 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 9 0.9.14.00 0.61.43.7 0.31.7.54 0.0 3.03.83 - - - 1000 1.1.33.17 0.84.6.45 0.56.91.7 0.6 3.4 3.03 - - - 1050 1.34.55.37 1.05.86.67 0.76 3.17.96 0.53 4.06 3.79 0.7 4.53 4. 1090 1.55.7.54 1.5 3.06.86 1.01 3.78 3.53 0.69 4.8 3.99 0.46 4.79 4.46 1105 1.66 3.08.87 1.38 3.45 3. 1.09 3.88 3.6 0.76 4. 4.06 0.54 4.89 4.56 1140 1.83 3.5 3.03 1.54 3.66 3.41 1.6 4.11 3.83 0.93 4.53 4. 0.73 5.1 4.77 MODEL DCG150 - (SIDE DUCT APPLICATIONS) 4000 4500 5000 5500 00 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 9 1.00.14.00 0..43.7 0.40.7.54 0.11 3.03.83 - - - 1000 1.0.33.17 0.93.6.45 0.65.91.7 0. 3.4 3.03 0.16 4.0 3.91 1050 1.4.55.37 1.14.86.67 0.85 3.17.96 0.6 4.06 3.79 0.39 4.53 4. 1090 1.63.7.54 1.34 3.06.86 1.10 3.78 3.53 0.78 4.8 3.99 0.58 4.79 4.46 1105 1.74 3.08.87 1.47 3.45 3. 1.18 3.88 3.6 0.85 4. 4.06 0.66 4.89 4.56 1140 1.91 3.5 3.03 1.63 3.66 3.41 1. 4.11 3.83 1.0 4.53 4. 0.85 5.1 4.77 MODEL DCG150 - (BOTTOM DUCT APPLICATIONS) 4000 4500 5000 5500 00 RPM ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 9 0.77.14.00 0.40.43.7 0.04.7.54 - - - - - - 1000 0.97.33.17 0.63.6.45 0.9.91.7 - - - - - - 1050 1.19.55.37 0.84.86.67 0.49 3.17.96 0.6 4.06 3.79 - - - 1090 1.40.7.54 1.04 3.06.86 0.74 3.78 3.53 0.4 4.8 3.99 0.18 4.79 4.46 1105 1.51 3.08.87 1.17 3.45 3. 0.8 3.88 3.6 0.49 4. 4.06 0.6 4.89 4.56 1140 1.68 3.5 3.03 1.33 3.66 3.41 0.99 4.11 3.83 0.66 4.53 4. 0.45 5.1 4.77 NOTES: 1. Blower performance includes a wet evaporator coil and " filters.. For DCG units, blower performance includes the maximum number of heat exchangers. 3. Refer to the Accessory Static Resistances table. ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower. 4. DCE models include a baffle to direct the proper flow of air across our electric heaters. On cooling only applications, this baffle MUST be removed to get the ESP values listed in the above tables. = Larger Horsepower Alternate Motor Required. 1 Unitary Products Group

MOTOR AND DRIVE DATA MODELS RANGE (RPM) HP SERVICE FACTOR MOTOR* FRAME SIZE EFFICIENCY (%) ADJUSTABLE MOTOR PULLEY PITCH BORE DIA. (IN.) (IN.) FIXED PULLEY PITCH BORE DIA. (IN.) (IN.) PITCH LENGTH (IN.) BELTS DESIG- NATION DCE090 1-1/, DCG090 975-10 1.0 56 8.0 3.4-4.4 7/8 6. 1 50.3 A48 1 DCE10, 3 DCG10 DCE10, 3 DCG10 8-1090 1.0 56 8.0 3.4-4.4 7/8 7.0 1 57.3 A55 1 DCE150 3 DCG150 DCE150 BX61 9-1140 5 1.15 184 8.0 4.9-5.9 1-1/8 8.9 1 6.8 1 DCG150 (Notched) * All motors are 1750 RPM, have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. 530.18-TGY QTY. ACCESSORY STATIC RESISTANCES* MODELS DCE DCG DCE EXTERNAL STATIC PRESSURE DROP RESISTANCE, IWG DESCRIPTION 50 3000 4000 5000 00 Economizer 0.0 0.0 0.03 0.05 0.07 Electric Heaters 9 KW** 18 KW 0.06 0.11 0.0 0.31 0.45 4 KW 0.1 0.1 0.33 0.48 36 KW 0.07 0.13 0.3 0. 0.5 54 KW*** - 0.15 0.6 0.40 0.58 *Deduct these resistance values from the available unit external static pressure shown in the respective Blower Performance Table. **9 KW Heater is only available on 7-1/ and 8-1/ Ton Units. ***54 KW Heater is only available on 10 and 1-1/ Ton Units. COMPONENT WEIGHTS Basic Unit Options and Accessories NOTE: Weights are given in pounds. COMPONENT MODELS DCE & DCG 7-1/ TON 8-1/ TON 10 TON 1-1/ TON DCE (Cooling only) 940 105 10 150 130 Mbh 100 1105 - - DCG (Gas / Electric) 165 Mbh 1040 115 11 1450 00 Mbh - - 1180 14 Economizer 77 77 77 77 Motorized Outdoor Air Damper 97 97 97 97 Oversized Motor 10 15 15 9 KW 19 19 - - Electric Heat 18 KW 4 4 4 4 (Nominal KW) 4 KW 7 7 7 7 (DCE only) 36 KW 30 30 30 30 54 KW - - 37 37 Roof Mounting Curb 155 155 155 155 Unitary Products Group 13

530.18-TGY FIELD WIRING - DCE/DCG Electric/Electric and Gas/Electric Units 14 Unitary Products Group

530.18-TGY ELECTRICAL DATA - Cooling / Electric Heating (DCE090 & 10) UNIT SIZE, D3CE 090 7-1/ TON UNIT with 1-1/ OR HP 10 8-1/ TON UNIT with OR 3 HP POWER SUPPLY SUPPLY AIR FLA MOTOR HP 08-3- 5.7 7.5 ACCESSORY ELECTRIC HEATERS TOTAL UNIT AMPACITY, AMPS MOTOR HP MAXIMUM FUSE SIZE, 1, AMPS TOTAL MODEL NO. KW STAGES LO HI AMPS LO HI LO HI HE0451095 6.8 1 18.8 39.8 41.6 50 50 HE0451185 13.5 37.5 54.0 56.3 HE045145 50.0 69.7 71.9 80 HE0451365 7.0 75.1 100.9 103. 110 110 30-3- 5.7 7.5 4-3-.6 3.4 575-3-.1.7 08-3- 7.5 10.6 30-3- 7.5 10.6 4-3- 3.4 4.8 575-3-.7 3.9 HE0451095 HE0451185 HE045145 HE0451365 HE04510946* HE04511846* HE0451446 HE04513646 HE04510958 HE04511858 HE0451458 HE04513658 HE0451095 HE0451185 HE045145 HE0451365 HE0451095 HE0451185 HE045145 HE0451365 HE04510946* HE04511846* HE0451446 HE04513646 HE04510958 HE04511858 HE0451458 HE04513658 1 Dual element, time delay type. Maximum HACR breaker of the same AMP size is applicable, except 575 voltages. Standard circuit breakers may be used in Canada and on applications over amps where the heaters are separately fused.. *These electric heaters do NOT include fuses. If fuses are required to meet a local code (eg. Chicago), an accessory fuse box with fuses (FB040346) is available for field installation. 9.0 4.0 36.0 9.0 4.0 36.0 9.0 4.0 36.0 6.8 13.5 7.0 9.0 4.0 36.0 9.0 4.0 36.0 9.0 4.0 36.0 1 1 1 1 1 1 1 1.7 43.3 57.7 86.6 10.8 1.7 8.9 43.3 8.7 17.3 3.1 34.6 18.8 37.5 50.0 75.1 1.7 43.3 57.7 86.6 10.8 1.7 8.9 43.3 8.7 17.3 3.1 34.6 39.8 61.3 79.3 115.4 0.3 30.3 39.3 57.4 17.8 4.3 31.5 45.9 48. 56.3 71.9 103. 48. 63.5 81.5 117.6 4.8 31.3 40.3 58.4 1. 5.0 3. 46.7 41.6 63.5 81.5 117.6 1.1 31.3 40.3 58.4 18.4 5.0 3. 46.7 51.3. 75.8 107.1 51.3 67.4 85.4 11.5 6. 33.1 4.1.1.4 6.5 33.7 48. 50 80 15 5 40 0 5 50 80 110 90 15 30 45 5 5 50 50 90 15 5 45 0 30 50 80 110 90 15 30 45 5 30 50 ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE KW CAP. MULTIPLIER 08 08 1.00 40 30 0.9 480 4 0.9 0 575 0.9 Unitary Products Group 15

530.18-TGY ELECTRICAL DATA- Cont d.- Cooling / Electric Heating (DCE10 & 150) UNIT SIZE, D3CE 10 10 TON UNIT with OR 3 HP 150 1 TON UNIT with 3 OR 5 HP POWER SUPPLY SUPPLY AIR FLA MOTOR HP 08-3- 7.5 10.6 ACCESSORY ELECTRIC HEATERS TOTAL UNIT AMPACITY, AMPS MOTOR HP MAXIMUM FUSE SIZE, 1, AMPS TOTAL MODEL NO. KW STAGES LO HI AMPS LO HI LO HI HE0451185 13.5 37.5 56.3. HE045145 50.0 71.9 75.8 80 80 HE0451365 7.0 75.1 103. 107.1 110 110 HH0451545 40.6 11.6 150.1 154.0 175 175 30-3- 7.5 10.6 4-3- 3.4 4.8 575-3-.7 3.9 08-3- 10.6 15.1 30-3- 10.6 15.1 4-3- 4.8 7.5 575-3- 3.9 5.9 HE0451185 HE045145 HE0451365 HH0451545 HE04511846* HE0451446 HE04513646 HE04515446 HE04511858 HE0451458 HE04513658 HE04515458 HE0451185 HE045145 HE0451365 HH0451545 HE0451185 HE045145 HE0451345 HH0451545 HE04511846* HE0451446 HE04513646 HE04515446 HE04511858 HE0451458 HE04513658 HE04515458 1 Dual element, time delay type. Maximum HACR breaker of the same AMP size is applicable, except 575 voltages. Standard circuit breakers may be used in Canada and on applications over amps where the heaters are separately fused.. *These electric heaters do NOT include fuses. If fuses are required to meet a local code (eg. Chicago), an accessory fuse box with fuses (FB040346) is available for field installation. 4.0 36.0 54.0 4.0 36.0 54.0 4.0 36.0 54.0 13.5 7.0 40.6 4.0 36.0 54.0 4.0 36.0 54.0 4.0 36.0 54.0 ELECTRIC HEAT CORRECTION FACTORS 43.3 57.7 86.6 19.9 1.7 8.9 43.3 65.0 17.3 3.1 34.6 5.0 37.5 50.0 75.1 11.6 43.3 57.7 86.6 19.9 1.7 8.9 43.3 65.0 17.3 3.1 34.6 5.0 63.5 81.5 117.6 139.3 31.3 40.3 58.4 69. 5.0 3. 46.7 55.3 66.6 75.8 107.1 154.0 67.4 85.4 11.5 143. 33.1 4.1.1 71.0 9.1 33.7 48. 56.8 67.4 85.4 11.5 143. 33.1 4.1.1 71.0 6.5 33.7 48. 56.8 71.1 81.4 11.7 159.6 73.0 91.0 17.1 148.8 36.4 45.5 63.5 74.3 31.1 36. 50.7 59.3 90 15 150 45 80 30 50 80 80 110 175 80 90 15 175 40 45 80 50 90 15 175 45 80 30 50 90 90 15 175 90 100 150 175 40 50 90 40 40 NOMINAL VOLTAGE VOLTAGE KW CAP. MULTIPLIER 08 08 1.00 40 30 0.9 480 4 0.9 0 575 0.9 16 Unitary Products Group

530.18-TGY UNIT DIMENSIONS (DCE AND DCG - 7-1/ THRU 1-1/ TON) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. RETURN AIR SUPPLY AIR CONDENSER AIR OUTDOOR AIR (Economizer) UTILITIES ENTRY DATA HOLE OPENING SIZE (DIA.) USED FOR A 3/4" KO Control Side 7/8" KO Wiring Bottom* B " KO Power Wiring (Side or Bottom)* C " KO Gas Piping (Front) D 1-11/16" Hole Gas Piping (Bottom)* *Openings in the bottom of the unit can be located by the slice in the insulation. CLEARANCES Front 4" 1" (Less Economizer) Back 36" (With Economizer/ Outdoor Air Damper) 4" (Less Economizer) Left Side (Filter Access) 54" (With Economizer) 3 Right Side (Cond. Coil) 4" Below Unit 1 0" 7" With 36" Maximum Above Unit Horizontal Overhang (For Condenser Air Discharge) 1 Units may be installed on combustible floors made from wood or class A, B or C roof covering material. Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. 3 If economizer is factory installed, the assembled hood kit must be removed prior to final installation. This hood is 54" long. NOTE: DCE Models: Units and ductwork are approved for zero clearance to combustible materials when equipped with electric heaters. DCG Models: A 1" clearance must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood is at least: Three (3) feet above any forced air inlet located within 10 horizontal feet (excluding those integral to the unit). Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air inlet into the building. Four (4) feet from electric meters, gas meters, regulators and relief equipment. Unitary Products Group 17

530.18-TGY UNIT DIMENSIONS - Cont d. -(DCE and DCG - 7-1/ THRU 1-1/ TON) DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers..connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply and return air duct covers to gain access to the bottom supply and return air duct covers.. Remove and discard the bottom duct covers. 3. Replace the side duct covers. DETAIL X SIDE SUPPLY AND RETURN AIR DUCT OPENINGS DETAIL Y UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS DIM. UNIT 7-1/ TON 8-1/ TON 10 TON 1-1/ TON A 33-1/4" 3" 3-1/" 3-1/" B 47-1/" 44-1/" 46-3/4" 45" CENTER OF GRAVITY 18 Unitary Products Group

530.18-TGY POINT LOADS DCE UNIT 4 POINT LOADS 4 - POINT LOADS (LBS) TOTAL A B C D 090 1077 38 66 303 10 110 19 77 338 68 10 1177 50 89 34 96 150 137 71 336 398 3 6 POINT LOADS DCE UNIT 6 - POINT LOADS (LBS) TOTAL A B C D E F 090 1077 158 168 178 0 191 180 10 110 146 166 185 5 0 178 10 1177 167 179 193 8 13 197 150 137 181 0 4 66 40 14 NOTE: These weights are with economizer and 4kW electric heat. DCG 4 - POINT LOADS (LBS) UNIT TOTAL A B C D 090 1187 6 98 333 94 10 10 39 9 369 30 10 131 79 330 381 3 150 158 33 383 475 401 DCG 6 - POINT LOADS (LBS) UNIT TOTAL A B C D E F 090 1187 175 198 10 196 186 10 10 1 194 0 45 0 181 10 131 186 0 37 54 15 01 150 158 15 56 86 317 67 41 NOTE: These weights are with economizer, high heat and oversized motor. Unitary Products Group 19

530.18-TGY ROOF CURB DIMENSIONS - (DCE and DCG - 7-1/ THRU 1-1/ TON) ROOF CURB BENEFITS 9/16 *Supply and Return Air (including duct support rails) as shown, are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimension details. ➀ The 4" space between the ducts allows for jumping an existing roof joist. ➁ The 41" overall dimension of the ducts allows ductwork penetration between roof joists that are spaced on 48" centers. NOTE: Ducts can be installed onto the curb from the roof. All electrical and gas line connections can be made inside the curb. UNIT AND CURB APPLICATION 3.69" 3.56" BASE RAIL 0 Unitary Products Group

530.18-TGY TYPICAL APPLICATIONS TYPICAL ROOF-TOP INSTALLATION (ELECTRIC/ELECTRIC UNIT SHOWN) Unitary Products Group 1

530.18-TGY FACTORY INSTALLED OPTIONS ECONOMIZERS: Units equipped with the factory-installed economizer option have dampers that are positioned by a spring return, fully modulating damper actuator capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is determined by a single input electronic enthalpy control or by a dual input electronic enthalpy control. Simultaneous compressor and economizer operation is also possible. Economizer dampers are % low leakage type. A barometric relief damper is shipped in the return air compartment for field installation. The single enthalpy system contains a sensor that monitors the outdoor air which automatically operates the damper actuator allowing the dampers to open or close. The dual enthalpy system contains a second sensor that monitors the return air in addition to monitoring the outdoor air described above for a single enthalpy system. The logic module compares these two values and modulates the dampers providing the maximum efficiency of the economizer system. The economizer is completely wired and installed at the factory. Only the outdoor air hood, including its filters, need be assembled and installed in the field. ALTERNATE INDOOR FAN MOTORS: Larger horsepower motors are available on most models to handle higher static pressure applications. FIELD-INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide-in / plug-in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rainhood with filters. The rainhood is painted to match the basic unit and must be field-assembled before installation. Economizer dampers are % low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rainhood with filters as described for a single enthalpy economizer above except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes slide-in / plug-in damper assembly with rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. Damper capable of providing 0% thru 100% of outdoor return air opening. MANUAL OUTDOOR DAMPER - Provides 0% thru % or 0% thru 100% of outdoor return air opening (field adjustable). Designed for duct mounted side or bottom supply/return applications. includes both hood assembly and filters. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities of 9, 18, 4, 36 and 54 KW heating are available. FUSE BLOCK KIT - This kit contains a fuse block including the fuses and is available for the 9 and 18 KW 4-volt heater kits. This kit satisfies the Chicago code requirements. ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly. Its duct supports and insulated condensing section deck can be reversed to connect the ductwork on the opposite end. LOW AMBIENT KIT - Head pressure controllers maintain stable operation by reducing the speed of the condenser fan motors when the outdoor temperature is between 45 and 0 F. Condenser fan motors with ball bearings and heavier windings are available for these low ambient applications. ANTI-RECYCLE TIMER - A timer to prevent unit compressors from short cycling. It assures a 5-minute off-time between compressor cycles. PROPANE CONVERSION KIT - Converts a gas-fired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a gas valve. GAS PIPING - This kit contains 3/4" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut-off. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6,000 ft. For propane applications, the propane conversion kit will also be required. WALL THERMOSTAT - The units are designed to operate with 4-volt electronic and electro-mechanical thermostats. All electric / electric and gas / electric units operate with two stage heat / two stage cool thermostats (with or without an economizer). Unitary Products Group

530.18-TGY Unitary Products Group 3

Unitary Products Group P.O. Box 159, York, Pennsylvania USA 17405-159 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 1998. All Rights Reserved. Codes: EBY,EGY 530.18-TGY Supersedes: 530.18-TGY (1095)