solenoids & relays solenoids & relays Continuous Duty 24V insulated 48V insulated 36V insulated A UL-listed

Similar documents
solenoids & relays solenoids & relays

SWITCHES SECTION. Fuse Holders. Toggle Switches - Screw Terminals. Fuses. Toggle Switches - Blade Terminals. Terminal Block - Junction Box

rotary & headlamp switches

Info Sheet. Listing of Cole Hersee retail packs. Littelfuse Commercial Vehicle Products PDF 105

Switches. Common Used Terminology:

Electro Wizard TM Battery Disconnect Switch

battery-related products

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

SWITCHES & ELECTRICAL ASSEMBLIES

push-pull, rotary & headlamp

Timer Relays - Fixed & Adjustable

Pilot Lights and Warning Devices

circuit protection & wiring accessories

8500 Series Subminiature Pushbutton Switches

Item Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203.

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

BATTERY DISCONNECT SERVICE MANUAL

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

Basics of Control Components

AEC Weekend Seminars Switches, Relays and Contactors. Switches, Relays and Contactors

special purpose switches

Programmable Logic Controller. Mat Nor Mohamad

VALVE BODY. Shift Pressure Control Solenoid Valve. 1. Leaf spring 2. Contact spring 3. Conductor track 4. O-ring 5. O-ring 6.

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

Electro Wizard Battery Disconnect Switch

General Specifications

Industrial Control Transformers

Bringing Component Parts Together

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

Starting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points

TA Ta VA CTRL-XFRMR

2006 MINI Cooper S GENINFO Starting - Overview - MINI

Function Relays, Interfaces and Converters

Battery Operation. Battery Construction. Battery State Of Charge. Battery Load Test. Battery Rating Systems 2/14/12

General Specifications

MODEL EVA PARTS MANUAL Rev.1.03

M O D E L S EST- FL PARTS MANUAL Rev 1.00A

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES


table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

circuit protection & wiring accessories

colehersee.com heavy duty catalog Manufacturers of DC electrical and electronic switches and connectors for the vehicle industry

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

The Electromagnet. Electromagnetism

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

ELECTRICITY AND HWH COPPER CONDUCTOR

D. S. HULL COMPANY, INC

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9

MODEL EVA PARTS MANUAL Rev.1.05

Magnetic Alarm Switches

Street Trucks Groundskeeping Cranes of all kinds Agriculture, Forestry & Mining

Electropneumatic Timing Relays Series 7000 Industrial

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

Control Relays Overview

Cruise Control Wiring

Distinctive Characteristics

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Miniature microswitches - Positive break

Deep Well Pump Control Valve

The world s leading independent supplier of energy control solutions for engines, turbines, and power equipment.

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

Service Manual for Battery Control Center

Reversing Hand Throttle and Horn Relay Board RBT / HRB

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Liftgate Terminology

Solenoid valve. Solenoid Coil

Electromagnetic Induction

circuit protection & wiring accessories

electronic devices electronic devices MINIBUS DIGITAL DATABUS SYSTEM MiniBus Digital Databus System System Features System components

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Automotive Parts. Charging & Starting Systems

8 Channel 5V Optical Isolated Relay Module

Tattletale Annunciators and Magnetic Switches

Booster Pump Control Valve

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

MODEL CMA-44 PARTS MANUAL Rev 2.13

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Switch Machines Installation & Wiring

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

BERMAD Irrigation. Solenoid Valves S - Series. Water Control Solutions

SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive)

» Principals of Spider -Valve VA series

HYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS and APPLICATION... p.

HYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS and APPLICATION... p.

Power systems Protection course

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

PRODUCT CATALOG 2004 SOLENOIDS ACTUATORS ENGINE CONTROLS ELECTROMAGNETIC CONTROLS AND SYSTEMS

Electricity Merit Badge

Dissolved Oxygen Measurement System with Air Blast Cleaner

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

S (8.0) (5.15).551 (14.0) .275 (7.0) S100

AP MOTRONIX PRIVATE LIMITED

Note 8. Electric Actuators

Transcription:

PVC COATED SOLENOIDS WITH STEEL HOUSINGS PLASTIC ODY SOLENOIDS ELECTRONIC SOLENOIDS RELAYS H H H H4 H5 H H INFORMATION ON SOLENOIDS H6 Continuous Duty 85A except where noted. Normally Open Contacts, SPST, One circuit: Off - On Housings: Plated steel (Phenolic where noted). Contacts: Copper 5/6" -4 thread, hexnuts and lockwashers included. 00A solenoids have silver contacts. Coil, ignition and ground terminals: Steel 0- thread, hexnuts and lockwashers included. racket mounting holes 5/6" x 9/" (7.9 x 5.) on /64" centers (56.0mm). 48V insulated See Section H: 4848 heavy duty. 6V insulated Available in Plastic ody (section H): 466, 486 heavy duty. 4080 4V insulated Also available in Plastic ody (section H): 464-0. 406 PVC coated and UL-rated model: see 406-08 407 444 00A PVC coated model: see 45 4080-0 UL-listed Same as 4080, but UL and CE rated. Continuous Rating: 65A at 6V DC. Intermittent rating: 0A make, 65A break. 0 sec On, 0 min Off. PVC coated model: see 45-0 Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 75 Electrical Rating: 00A carry only. Not to break 00A at 4V DC. Silver contacts. CONTINUED H T 67.68.00 F 67.68.9490 www.colehersee.com

H H 4V grounded 44 440 Normally On V insulated 45 Continuous Duty 5A. 4 V grounded Also available in Plastic ody (section H): 46-G0. 406 P 4059 P 408 curved bracket PVC coated model: see 47 4059-08 UL listed P Same as 4059, but UL and CE rated. Continuous Rating: 65A at V DC. Intermittent rating: 750A make, 00A break. 0 sec On, 0 min Off. Circuit G. PVC coated model: see 47-0 6V 4097 insulated 44 00A 405 grounded Electrical Rating: 00A. Silver contacts. 76 Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 T 67.68.00 F 67.68.9490 www.colehersee.com

H H Two circuits, DPST Normally Off and Normally On. Special application: for forward and reverse systems in electric golf carts, garden tractors, fork lift trucks, winches, etc. Housing: Steel. Continuous Duty, Normally Closed contacts 5A, Normally Open contacts 85A. 4400 6V insulated Latching Solenoid V Continuous Duty,0A (carry only). Insulated. Plated steel housing. Requires only a momentary application of coil power to operate. Very little heat is generated, because the coil is de-energized when the solenoid is On. 400 Momentary Switch + AT 4 5 6 LOAD 440 4V insulated Schematic and picture same as 4400. 440 V insulated Schematic and picture same as 4400. PVC coated model: see 440-04. 440-0 V grounded the latching solenoid motor reversing 4 5 Typical DC series wound permanent magnet circuit, using a pair of double-action solenoids. Use pairs of the following solenoids: 440 (V), 440 (4V), or 4400 (6V). SPDT Control Switch Fwd Rev This special solenoid toggles On and Off, and requires no current to maintain the continuity of the power circuit. Use it with a momentary switch (see Momentary Switches). Actuation of the momentary switch causes current to flow in the solenoid coil, locking the contact in place, maintaining the load circuit in an On position. A second actuation of the momentary switch releases the plunger, turning the load circuit Off. Suggested momentary switches: 5507, 5807-0. Special Applications Remote battery isolator In a two-battery system, use the Latching Solenoid to isolate the batteries from each other, and prevent battery drain from the higher into the lower. It has an advantage over electronic attery Isolators (see attery-related Products), in that it will not produce a voltage drop during operation. 440X Series Solenoid 440X Series Solenoid Remote battery disconnect Use it as a remote attery Disconnect Switch. This eliminates the need for heavy gauge wiring between the control panel and the battery. 4 4 To Motor + 5 6 5 6 To Motor CONTINUED H Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 77 T 67.68.00 F 67.68.9490 www.colehersee.com

H H Intermittent Duty Normally Off, SPST, One circuit: Off - On 750A make, 00A break, 0sec On, 0min Off, except where noted. Contacts: Copper. Terminals: Copper. Small ignition and ground terminals are 0- thread. Large contact terminals are 5/6" -4 thread. Hexnuts and lockwashers are included. racket mounting holes 5/6 x 9/," /64" on centers (7.9 x 5., 56.0mm) and plated steel housing, except where noted. 4V insulated 0A make, 65A break. 0 sec On, 0 min Off. 4008 4044, angled bracket 400 phenolic housing, curved bracket 40 phenolic housing 404 V grounded Also available in Plastic ody (section H): 47-GS7, 46-G. V grounded, Resistor Shorting Circuit In this application, is Normally Open. It becomes common with and 4 when the solendoid is energized. Commonly used in engine starting applications. racket mounting holes 9/" x 5/64," 7/64" on centers (7. x 9.9, 5.6mm). RESISTOR SHORTING CIRCUIT 407 40 M-0 marine PVC coated model: see 407. 40 phenolic housing Marine construction. Clear protective finish, brass hexnuts and lockwashers. racket mounting holes 9/ x /," /64" on centers (7. x.7, 56.0mm). Contact terminal 5/6" -4 thread. 78 Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 T 67.68.00 F 67.68.9490 www.colehersee.com

H H 48 phenolic, with breather 40 phenolic housing racket mounting holes 9/ x /," /64" on centers (7. x.7, 56.0mm). Contact terminal 5/6" -4 thread. V insulated Also available in Plastic ody (section H): 45-0, 45-, 46-, 47-S6, 47-S7. 4047 racket mounting holes 5/6" x 9/," 9/6" on centers (8. x 7., 65.mm). 40 phenolic housing PVC coated model: 4076 M-00 marine P Same as 4047, but marine construction. Clear protective finish, brass hexnuts and lockwashers. 6V grounded 404 M-00-0 marine, UL listed Same as M-00, but with UL & CE listing. Intermittent rating: 750A make, 00A break.0 sec On, 0 min Off. 4060 409 curved bracket 4046 6V insulated 404 PVC coated model: 4077 Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 79 PVC COATED H T 67.68.00 F 67.68.9490 www.colehersee.com

H H5 RELAYS Relay Sockets Accepts Cole Hersee relays and standard ISO relays. Modular sockets dovetail together. Accepts standard quick-connect terminals. Easy mount bracket. Constructed of rugged glass-filled polyamide. Temperature range -40F to 85C. 9905 High Power Socket 9906 Heavy Duty Socket For use with Cole Hersee Heavy Duty Relays. Form A (SPST) or Form C (SPDT). Use with Tyco (AMP) terminals 48 or Ark-Les 000HA series (consult terminal manufacturers for full specs). For use with Cole Hersee High Power Relays. Form A (SPST) Use with Tyco (AMP) terminals 80756 or 80755 (consult terminal manufacturers for full specs). H6 INFORMATION ON SOLENOIDS Solenoids are relays which are commonly used to remotely switch a heavier current. y using a solenoid, the amount of heavy wiring needed to power the load is reduced, since the control circuit mounted inside the cab typically utilizes a smaller wire gauge. Solenoids are commonly used to control starter and winch motors, and they have many other uses on vehicles of all kinds. The diagram shows a magnetic coil surrounding a contact plunger. efore energization, the plunger is not electrically connected to the control circuit. When the control circuit is energized, the electromagnetic force induced in the coil attracts the plunger, which moves to close the load circuit. When the control circuit is de-energized, the spring-loaded plunger returns to its normal state and the load circuit is broken. In continuous duty applications, energization of the coil causes heating, therefore the solenoid housing will become warm even in normal operation. CONTROL CIRCUIT STUDS CONTROL CIRCUIT STUDS COIL HOUSING PLUNGER LOAD CIRCUIT STUDS A typical 4-stud solenoid LOAD CIRCUIT STUDS 4-stud solenoid diagram L Solenoid in its normal state Control circut and load circuit open Energized solenoid Control circut and load circuit closed L For more information on solenoids, visit the interactive training section of the Cole Hersee website: www.colehersee.com > Resource Center > Training. 88 Cole Hersee Co. 0OldColonyAve, oston, MA 07-467 T 67.68.00 F 67.68.9490 www.colehersee.com