PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Similar documents
PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66

POWERPLEX PANELBOARD 1

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

Explosionproof Protection Simplified

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Panelboard Protection on a Global Scale

ATX DPD Series Distribution Panelboards Flameproof

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

CIRCUIT BREAKER PANELBOARDS

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

Lighting and Power Distribution Panelboards

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Quik-Spec Coordination Panelboard Specifications

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

SECTION PANELBOARDS

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Power distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards

Division 1 Explosionproof Panelboards

GREATER VERSATILITY WITH LESS DOWNTIME

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

X1PB: Explosionproof Panelboards

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

PANELBOARDS C1/C2 SECTION 6

SynergEX Panelboards for Hazardous Locations

Design Standard. Purpose: Design Standard:

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Product Specification Sheet #3LD2.1

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Applications. Illustrated Features

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Circuit Breakers Hazardous

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

BUSWAY Low Voltage (Pow-R-Flex)

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Eylander Electric Inc

F-Series. Circuit Breaker

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Application guide. Tmax Link OEM UL 891 Switchboard Program

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

F-Series. Circuit Breaker

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Specialty Service Entrance Switchboards. Selection and Application Guide

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

SECTION MOTOR CONTROL

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Standard Materials Bodies and covers: copper-free aluminum.

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

EBMC Combination Line Starters and Enclosures

CUBEFuse. CUBEFuse catalog numbers (amps)

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

LFJ602003C 200A 600V Fus Block

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Studded Power Feed Thru Terminal Blocks

SWITCHGEAR DIVISION PRODUCT PROFILES

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Service Entrance Methods

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Transcription:

Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater Treatment Plants Paper and Pulp Industries Other process facilities Ideal for placement in wet, corrosive environments or where flammable gases or vapors are likely to be present. Suitable for use on lighting, heat trace, power circuits and Uninterruptible Power Supply (UPS) applications. Features No external conduit or cable seals required thus making installations faster, easier, and less costly. The PlexPower panelboard features a ground-breaking design that uses individual fuse housings to minimize the downtime and costs associated with servicing fuses in hazardous locations. PlexPower fuses accommodate off-the-shelf fuses and switches making replacements readily available. The lighter weight panelboard enclosure can be quickly opened in the field for easier servicing. Supplied with standard hard drawn, tin plated, copper bus bar for superior corrosion resistance. Gland plate can be easily field punched for cable or conduit entries. Standard model includes plate on the same side as the main connection. Additional gland plates must be ordered with the panelboard. See options. RFF model up to 600 V panel. Standard fused models offer up to 18 circuit panelboard configurations. Fused models are available standard with or without main breaker, depending on the configuration; up to 30 Amps per branch circuit. Standard configuration includes internal actuators and a solid door; factory installed options include external actuators. Supplied with dead front for internal and external actuation. Main circuit breaker up to 150 Amps. Breakers and switches can be padlocked in either the On or Off position. Breaker, switch and fuse modules supplied with captive bolts. Ground bar provided as standard. External/internal ground lug provided as standard. Main breakerutilizes Cutler-Hammer F-Frame Series circuit breakers rated -20 C to +40 C (-4 F to +104 F). Standard model utilizes Cutler-Hammer F-Frame Series FD molded case switches for each branch circuit. Appleton breaker and fuse modules accommodate standard off-the-shelf replacement breakers and fuses. Utilizes standard Marathon Special Products fuse holder R6J30A1S for use with any Class J series fuse. Fused Factory Sealed Panelboard Illustrated Features Dead Front Standard Bus Bar Off Shelf Fuses and Fuseholders Marathon Special Products is a registered trademark of Regal-Beloit Corporation. Cutler-Hammer is a registered trademark of Eaton Corporation. 313

Standard Materials Enclosure: 304 stainless steel Alternate enclosure: 316L stainless steel Hardware: stainless steel Bus bar: hard drawn, tin plated, copper Options Must be listed in alphanumeric sequence at the end of the catalog number. 316L stainless steel enclosure material, add suffix 316L. Drain/breather, add suffix DV. External actuation, add suffix EXT. Grounded neutral, add suffix GN. Gland plate, specify suffix GPL = left side, GPR = right side, GPT = opposite mains, NGP = no gland plate). LED indicator lights, add suffix IL. Bottom feed, add suffix INV. Phenolic nameplate (specify legend), add suffix NP. Door padlocking provision, add suffix P. Stainless steel legend plate (specify legend), add suffix SP. Fuse Specifications NEC/CEC Certifications and Compliances UL Standards: ANSI/UL 67, ANSI/ISA 12.12.01, ANSI/UL 1203, ANSI/UL 60079-0, ANSI/UL60079-1, ANSI/UL60079-7 CSA Standards: C22.2 No. 29, C22.2 No. 0, C22.2 No. 213, CAN E60079-0, CAN E60079-7, CAN E60079-1 CSA C22.2 No. 248.1-11 (Low-Voltage Fuses Part 1: General Requirements) CSA C22.2 No. 248.1-11 (Low-Voltage Fuses Part 8: Class J Fuses) ccsaus Certified: 039199 UL Recognized Component (US and Canada): E319372 Fuse Specific Certifications JLS and JTD Fuses Standard 248-8, Class J UL Listed (File: E81895) CSA Certified (File: LR29862) Related Products Additional PlexPower products: PlexPower Factory Sealed Panelboard with Bus Bar PlexPower Factory Sealed Enclosed Circuit Breakers Series Type Amperage Rating Interrupting Ratings Voltage Ratings JLS Fast Acting 1A 30A Up to 200 ka rms symmetrical 600 JTD Time Delay 8/10A 30A Up to 200 ka rms symmetrical 600 Cutler-Hammer is a registered trademark of Eaton Corporation. 314

Steps to Creating Catalog Number: Complete Catalog Number RFF S E1 3 1 M 12 100 1 15 T Step 1 Step 2 Step 3 Step 4 Step 5 Step 1: Choose basic catalog from numbering guide on subsequent page. Step 2: If a main breaker is desired indicate amperage rating. Example: RFFSE131M12 100 is a 12 circuit 3 phase panelboard with 100 amp main breaker. Step 3: First digits are the quantity of fuses, second is the fuse ampere rating, and third is the type of fuse. Example: 115T is 1 fuse, 15 amps, T for time delay fuse Step 4: Repeat step 3 for as many fuses as required Step 5: Options: Add option in alphanumeric order as listed PlexPower introduction page under Options. Panel Size Enclosure I1 E1 G1 Length 875 (34.50) 1130 (45.00) 1500 (60.00) Width 750 (30.00) 750 (30.00) 750 (30.00) Depth 250 (10.00) 250 (10.00) 250 (10.00) 315

Catalog Numbering Guide RFF S E1 3 1 M 12 100 1 15 T Fused Series: RFF - up to 600 V Fused Panel with F-Frame Switch and Class J fuse holder Panel Material: S - Stainless Steel (304 standard. For 316L use S here and add 316L suffix at end of catalog number) Step 1 Step 2 Step 3 Step 4 Step 5 3 Phase System Voltage: 2-240 3-120/208 4-277/480 5-480 6-347/600 7-600 Bus Rating: 1-150 Amp 2-180 Amp Main Type: M - Main Breaker (150 A Max) L - Main Lug Only (180 A Max) Number of Circuits: 03 06 09 12 15 18 Main Breaker Ampere Rating: 020-20AT 025-25AT 030-30AT 040-40AT 050-50AT 060-60AT 070-70AT 080-80AT 090-90AT 100-100AT 110-110AT 125-125AT 150-150AT Quantity of Branch Fuses: up to 18 Fuse Ampere Rating : 01-01AT 02-02AT 03-03AT 04-04AT 05-05AT 06-06AT 07-07AT 08-08AT 09-09AT 10-10AT 15-15AT 20-20AT 25-25AT 30-30AT Fuse Type: T - Time delay F - Fast acting Additional Branch Fuses: Repeat Step 3 Suffix for Other Options/ Features: Must be listed in alphanumeric sequence (See Options) Panel Size: Select enclosure based on number of circuits Bus Amps Main Type I1 E1 G1 875x750x250 1130x750x250 1500x750x250 180 Main Lugs 03, 06, 09 12, 15 18 150 Main Breaker 03, 06 09, 12 15 Fast acting fuses are available in the following amperages: 1, 3, 6, 10, 15, 20, 25 and 30. 316

Size I 09 Circuit With Main Lugs 875 mm (34.45 ) Size I 06 Circuit With Main Breaker 875 mm (34.45 ) 317

Standard Configuration: No Window, Internal Actuation Size E 15 Circuit With Main Lugs 483 mm (19.00 ) Mtg. 483 mm (19.00 ) Mtg. 1130 mm (44.49 ) Size E 12 Circuit With Main Breaker 483 mm (19.00 ) Mtg. 483 mm (19.00 ) Mtg. 1130 mm (44.49 ) 318

Standard Configuration: No Window, Internal Actuation Size G 18 Circuit With Main Lugs 688 mm (26.28 ) Mtg. 688 mm (26.28 ) Mtg. 1500 mm (59.06 ) Size G 15 Circuit With Main Breaker 688 mm (26.28 ) Mtg. 688 mm (26.28 ) Mtg. 1500 mm (59.06 ) 319